FCC Test Report Report No. : FD331334-01
SPORTON INTERNATIONAL INC. Page No. : 1 of 19
TEL : 886-3-327-3456 Report Version : Rev. 01
FAX : 886-3-327-0973
FCC Test Report
Equipment : BL600 Series Bluetooth Low Energy Module
Brand Name : Laird Technologies
Model No. : BL600-ST
Additional Model No. : BL620-ST
Standard : 47 CFR FCC Part 15B Canada Standard ICES-003 Issue 5
Device Class : Class B
Applicant : EZURiO Ltd. (– a business unit of Laird Technologies) Saturn House, Mercury Park, Wooburn Green, Bucks, HP10 0HH, UK
Manufacturer : Laird Technolgies 11160 Thompson Ave., Lenexa, Kansas, 66219, USA
The product sample received on Mar. 20, 2014 and completely tested on Mar. 21, 2014. We, SPORTON, would like to declare that the tested sample has been evaluated in accordance with the procedures given in ANSI C63.4-2009 and shown compliance with the applicable technical standards. The test results in this report apply exclusively to the tested model / sample. Without written approval of SPORTON INTERNATIONAL INC., the test report shall not be reproduced except in full.
Reviewed by:
Kent Chen / Assistant Manager
FCC Test Report Report No. : FD331334-01
SPORTON INTERNATIONAL INC. Page No. : 2 of 19
TEL : 886-3-327-3456 Report Version : Rev. 01
FAX : 886-3-327-0973
Table of Contents 1 GENERAL DESCRIPTION .................................................................................................................... 5
1.1 Information .............................................................................................................................................. 5 1.2 Support Equipment ................................................................................................................................. 6 1.3 Testing Applied Standards ..................................................................................................................... 6 1.4 Testing Location Information .................................................................................................................. 7 1.5 Measurement Uncertainty ...................................................................................................................... 7
2 TEST CONFIGURATION OF EUT......................................................................................................... 8
2.1 The Worst Case Measurement Configuration ........................................................................................ 8 2.2 Test Setup Diagram ............................................................................................................................... 9
3 TRANSMITTER TEST RESULT .......................................................................................................... 10
3.1 AC Power-line Conducted Emissions .................................................................................................. 10 3.2 Radiated Spurious Emissions .............................................................................................................. 13
4 TEST EQUIPMENT AND CALIBRATION DATA ................................................................................ 19
APPENDIX A. TEST PHOTOS ................................................................................................................. A1-A4
FCC Test Report Report No. : FD331334-01
SPORTON INTERNATIONAL INC. Page No. : 3 of 19
TEL : 886-3-327-3456 Report Version : Rev. 01
FAX : 886-3-327-0973
Summary of Test Result
Conformance Test Specifications
Report Clause
Ref. Std. Clause
Description Measured Limit Result
3.1 15.107 AC Power-line Conducted Emissions
[dBuV]: 0.1615500MHz 49.66 (Margin 15.72dB) - QP 34.37 (Margin 21.01dB) - AV
Ref. 3.1.1 Complied
3.2 15.109 Radiated Emissions [dBuV/m at 3m]: 2796.00MHz 46.26 (Margin 7.74dB) - PK
Ref. 3.2.1 Complied
FCC Test Report Report No. : FD331334-01
SPORTON INTERNATIONAL INC. Page No. : 4 of 19
TEL : 886-3-327-3456 Report Version : Rev. 01
FAX : 886-3-327-0973
Revision History
Report No. Version Description Issued Date
FD331334-01 Rev. 01 Initial issue of report Apr. 02, 2014
FCC Test Report Report No. : FD331334-01
SPORTON INTERNATIONAL INC. Page No. : 5 of 19
TEL : 886-3-327-3456 Report Version : Rev. 01
FAX : 886-3-327-0973
1 General Description
1.1 Information
This report is issued as a supplementary report to original Sporton report no. FD331334. The modification is the addition of multiple-listing model BL620-ST for marketing purpose and updates ANSI C63.4 standard to 2009 version. Therefore, all tests had been re-tested and presented in the following sections.
1.1.1 Equipment Authorization Category
FCC Equipment Authorization of Unintentional Radiators Category
Class B personal computers and peripherals: Declaration of Conformity or Certification
Class A personal computers and peripherals: Verification
Receivers operation above 960 MHz or below 30 MHz, except for radar detectors and CB receivers, do not require equipment authorization (verification, Declaration of Conformity, or certification)
Receivers operation within 30 MHz to 960 MHz, except for radar detectors and CB receivers, require equipment authorization (Declaration of Conformity)
1.1.2 RF General Information
RF General Information
Frequency Range (MHz) Evaluation Mode
2400-2483.5 v4.0 LE
1.1.3 Antenna Information
Antenna Category
Integral antenna (antenna permanently attached)
External antenna (dedicated antennas)
Antenna General Information
No. EUT Model Ant. Cat. Ant. Type Ant. Brand/Model Ant.
Connector Gain
(dBi)
1 BL600-ST External Dipole MAG. LAYERS SCIENTIFIC-TECHNICS CO., LTD EDA-8709-2G4R2-A40-CY
SMA Male Reverse
2.0
FCC Test Report Report No. : FD331334-01
SPORTON INTERNATIONAL INC. Page No. : 6 of 19
TEL : 886-3-327-3456 Report Version : Rev. 01
FAX : 886-3-327-0973
1.1.4 Type of EUT
Identify EUT
EUT Serial Number N/A
Presentation of Equipment Production ; Pre-Production ; Prototype
Type of EUT
Stand-alone
Combined (EUT where the radio part is fully integrated within another device)
Combined Equipment - Brand Name / Model No.: …
Plug-in radio (EUT intended for a variety of host systems)
Host System - Brand Name / Model No.: …
Other:
1.1.5 EUT Operational Condition
Supply Voltage AC mains DC
Type of DC Source Internal DC supply Host Battery
1.2 Support Equipment
Support Equipment
No. Equipment Brand Name Model Name Serial No.
1 Notebook DELL Latitude E6430 -
2 Printer EPSON XP30 QSDK002410
3 Mouse DELL MS111-L 2C3-00MM
1.3 Testing Applied Standards
According to the specifications of the manufacturer, the EUT must comply with the requirements of the following standards: 47 CFR FCC Part 15B Canada Standard ICES-003 Issue 5 ANSI C63.4-2009
FCC Test Report Report No. : FD331334-01
SPORTON INTERNATIONAL INC. Page No. : 7 of 19
TEL : 886-3-327-3456 Report Version : Rev. 01
FAX : 886-3-327-0973
1.4 Testing Location Information
Testing Location
Sporton Lab
ADD : No. 52, Hwa Ya 1
st Rd., Hwa Ya Technology Park, Kwei-Shan Hsiang,
Tao Yuan Hsien, Taiwan, R.O.C.
TEL : 886-3-327-3456 FAX : 886-3-327-0973
ICC Lab ADD : No.3-1, Lane 6, Wen San 3rd St., Kwei Shan Hsiang, Tao Yuan Hsein 333, Taiwan (R.O.C.)
TEL : 886-3-271-8666 FAX : 886-3-318-0155
Test Condition Test Site No. Test Engineer Test Environment Test Date
AC Conduction CO04-HY Skys Huang 21°C / 63% Mar. 21, 2014
Radiated Emission* 03CH02-WS Skys Huang 19°C / 68% Mar. 20, 2014
Note: * Sporton Lab subcontracts this test item to ICC lab (TAF:2732).
ICC lab is a TAF accreditation test firm and also is an approved provider of Sporton Lab.
1.5 Measurement Uncertainty
ISO/IEC 17025 requires that an estimate of the measurement uncertainties associated with the emissions test results be included in the report. The measurement uncertainties given below are based on a 95% confidence level (based on a coverage factor (k=2)
Measurement Uncertainty
Test Item Uncertainty Limit
AC power-line conducted emissions ±2.26 dB N/A
All emissions, radiated 30 – 1000 MHz ±3.90 dB N/A
Above 1 GHz ±4.20 dB N/A
FCC Test Report Report No. : FD331334-01
SPORTON INTERNATIONAL INC. Page No. : 8 of 19
TEL : 886-3-327-3456 Report Version : Rev. 01
FAX : 886-3-327-0973
2 Test Configuration of EUT
2.1 The Worst Case Measurement Configuration
The Worst Case Mode for Following Conformance Tests
Tests Item AC power-line conducted emissions
Condition AC power-line conducted measurement for line and neutral Test Voltage: 120Vac / 60Hz
Operating Mode Operating Mode Description
1 Receiver Mode
The Worst Case Mode for Following Conformance Tests
Tests Item Radiated Emissions
Test Condition Radiated measurement
Search Range Highest Frequency Generated or Used in Device
Upper Frequency of Radiated Measurement
Below 1.705MHz No radiated testing required
1.705MHz-108MHz 1GHz
108MHz-500MHz 2GHz
500MHz-1GHz 5GHz
Above 1GHz 5th harmonic of the highest frequency or 40 GHz, whichever is lower.
User Position
EUT will be placed in fixed position.
EUT will be placed in mobile position and operating multiple positions. EUT shall be performed two orthogonal planes.
EUT will be a hand-held or body-worn battery-powered devices and operating multiple positions. EUT shall be performed three orthogonal planes. The worst plane is Z.
Operating Mode Operating Mode Description
1 Receiver Mode
FCC Test Report Report No. : FD331334-01
SPORTON INTERNATIONAL INC. Page No. : 9 of 19
TEL : 886-3-327-3456 Report Version : Rev. 01
FAX : 886-3-327-0973
2.2 Test Setup Diagram
Test Setup Diagram - Radiated Test
FCC Test Report Report No. : FD331334-01
SPORTON INTERNATIONAL INC. Page No. : 10 of 19
TEL : 886-3-327-3456 Report Version : Rev. 01
FAX : 886-3-327-0973
3 Transmitter Test Result
3.1 AC Power-line Conducted Emissions
3.1.1 AC Power-line Conducted Emissions Limit
AC Power-line Conducted Emissions Limit (Class B)
Frequency Emission (MHz) Quasi-Peak Average
0.15-0.5 66 - 56 * 56 - 46 *
0.5-5 56 46
5-30 60 50
Note 1: * Decreases with the logarithm of the frequency.
3.1.2 Measuring Instruments
Refer a test equipment and calibration data table in this test report.
3.1.3 Test Procedures
Test Method
Refer as ANSI C63.4, clause 7.3 for AC power-line conducted emissions.
3.1.4 Test Setup
AC Power-line Conducted Emissions
FCC Test Report Report No. : FD331334-01
SPORTON INTERNATIONAL INC. Page No. : 11 of 19
TEL : 886-3-327-3456 Report Version : Rev. 01
FAX : 886-3-327-0973
3.1.5 Test Result of AC Power-line Conducted Emissions
AC Power-line Conducted Emissions Result
Operating Mode 1 Power Phase Neutral
Operating Function Receiver Mode
Note 1: “>20dB” means emission levels that exceed the level of 20 dB below the applicable limit. Note 2: “N/F” means Nothing Found emissions (No emissions were detected.)
FCC Test Report Report No. : FD331334-01
SPORTON INTERNATIONAL INC. Page No. : 12 of 19
TEL : 886-3-327-3456 Report Version : Rev. 01
FAX : 886-3-327-0973
AC Power-line Conducted Emissions Result
Operating Mode 1 Power Phase Line
Operating Function Receiver Mode
Note 1: “>20dB” means emission levels that exceed the level of 20 dB below the applicable limit. Note 2: “N/F” means Nothing Found emissions (No emissions were detected.)
FCC Test Report Report No. : FD331334-01
SPORTON INTERNATIONAL INC. Page No. : 13 of 19
TEL : 886-3-327-3456 Report Version : Rev. 01
FAX : 886-3-327-0973
3.2 Radiated Spurious Emissions
3.2.1 Radiated Spurious Emissions Limit
FCC Part 15B Radiated Spurious Emissions Limit (Class B)
Frequency Range (MHz) Field Strength (uV/m) Field Strength (dBuV/m) Measure Distance (m)
30~88 100 40 3
88~216 150 43.5 3
216~960 200 46 3
Above 960 500 54 3
Note 1: Test distance for frequencies at or above 30 MHz, measurements may be performed at a distance other than the limit distance provided they are not performed in the near field and the emissions to be measured can be detected by the measurement equipment. When performing measurements at a distance other than that specified, the results shall be extrapolated to the specified distance using an extrapolation factor of 20 dB/decade (inverse of linear distance for field-strength measurements, inverse of linear distance-squared for power-density measurements).
3.2.2 Measuring Instruments
Refer a test equipment and calibration data table in this test report.
FCC Test Report Report No. : FD331334-01
SPORTON INTERNATIONAL INC. Page No. : 14 of 19
TEL : 886-3-327-3456 Report Version : Rev. 01
FAX : 886-3-327-0973
3.2.3 Test Procedures
Test Method – General Information
The search for spurious emissions shall be from the lowest frequency internally generated or used in the receiver (e.g. local oscillator, intermediate or carrier frequency), or 30 MHz, whichever is higher, to at least 5 times the highest tunable or local oscillator frequency, whichever is higher, without exceeding 40 GHz.
Measurements may be performed at a distance other than the limit distance provided they are not performed in the near field and the emissions to be measured can be detected by the measurement equipment. When performing measurements at a distance other than that specified, the results shall be extrapolated to the specified distance using an extrapolation factor of 20 dB/decade (inverse of linear distance for field-strength measurements, inverse of linear distance-squared for power-density measurements).
Measurements in the frequency range 10 GHz - 40GHz are typically made at a closer distance 1m, because the instrumentation noise floor is typically close to the radiated emission limit.
For radiated measurement.
Refer as ANSI C63.4, clause 8.3.1.1 and 8.3.2.2 for radiated emissions from below 30 MHz.
Refer as ANSI C63.4, clause 8.3.1.1 and 8.3.2.2 for radiated emissions from 30 MHz-1 GHz. For the peak measurement is fully sufficient, as the max field strength as measured with the Peak-Detector meets the QP-Limit so that the QP level does not need to be reported in addition.
Refer as ANSI C63.4, clause 8.3.2.1 and 8.3.2 for radiated emissions from above 1 GHz. For the peak measurement is fully sufficient, as the max field strength as measured with the Peak-Detector meets the AV-Limit so that the AV level does not need to be reported in addition.
3.2.4 Test Setup
Radiated Spurious Emissions
Magnetic field tests shall be performed in the frequency range of 9 kHz to 30 MHz using a calibrated loop antenna. Electric field tests shall be performed in the frequency range of 30 MHz to 1000 MHz using a calibrated bi-log antenna and the frequency range of 1 GHz to 40 GHz using a calibrated horn antenna.
FCC Test Report Report No. : FD331334-01
SPORTON INTERNATIONAL INC. Page No. : 15 of 19
TEL : 886-3-327-3456 Report Version : Rev. 01
FAX : 886-3-327-0973
3.2.5 Radiated Emissions (Below 1GHz)
Radiated Emissions (Below 1GHz)
Operating Mode 1 Polarization V
Operating Function Receiver Mode
Note 1: “>20dB” means emission levels that exceed the level of 20 dB below the applicable limit. Note 2: “N/F” means Nothing Found emissions (No emissions were detected.) Note 3: Measurement receive antenna polarization: H (Horizontal), V (Vertical)
FCC Test Report Report No. : FD331334-01
SPORTON INTERNATIONAL INC. Page No. : 16 of 19
TEL : 886-3-327-3456 Report Version : Rev. 01
FAX : 886-3-327-0973
Radiated Emissions (Below 1GHz)
Operating Mode 1 Polarization H
Operating Function Receiver Mode
Note 1: “>20dB” means emission levels that exceed the level of 20 dB below the applicable limit. Note 2: “N/F” means Nothing Found emissions (No emissions were detected.) Note 3: Measurement receive antenna polarization: H (Horizontal), V (Vertical)
FCC Test Report Report No. : FD331334-01
SPORTON INTERNATIONAL INC. Page No. : 17 of 19
TEL : 886-3-327-3456 Report Version : Rev. 01
FAX : 886-3-327-0973
3.2.6 Radiated Emissions (Above 1GHz)
Radiated Emissions (Above 1GHz)
Operating Mode 1 Polarization V
Operating Function Receiver Mode
Note 1: “>20dB” means emission levels that exceed the level of 20 dB below the applicable limit. Note 2: “N/F” means Nothing Found emissions (No emissions were detected.) Note 3: Measurement receive antenna polarization: H (Horizontal), V (Vertical)
FCC Test Report Report No. : FD331334-01
SPORTON INTERNATIONAL INC. Page No. : 18 of 19
TEL : 886-3-327-3456 Report Version : Rev. 01
FAX : 886-3-327-0973
Radiated Emissions (Above 1GHz)
Operating Mode 1 Polarization H
Operating Function Receiver Mode
Note 1: “>20dB” means emission levels that exceed the level of 20 dB below the applicable limit. Note 2: “N/F” means Nothing Found emissions (No emissions were detected.) Note 3: Measurement receive antenna polarization: H (Horizontal), V (Vertical)
FCC Test Report Report No. : FD331334-01
SPORTON INTERNATIONAL INC. Page No. : 19 of 19
TEL : 886-3-327-3456 Report Version : Rev. 01
FAX : 886-3-327-0973
4 Test Equipment and Calibration Data
Test Item Conducted Emission
Test Site Conduction room / (CO04-HY)
Instrument Manufacturer Model No. Serial No. Calibration Date Calibration Until
EMC Receiver R&S ESCS 30 100174 Mar. 25, 2013 Mar. 24, 2014
LISN SCHWARZBECK
MESS-ELEKTRONIK NSLK 8127 8127-477 Jan. 21, 2014 Jan. 20, 2015
LISN
(Support Unit) EMCO 3810/2NM 9703-1839 Apr. 18, 2013 Apr. 17, 2014
RF Cable-CON HUBER+SUHNER RG213/U 07611832010001 Oct. 30, 2013 Oct. 19, 2014
50 ohm terminal (Support Unit) N/A N/A
CON-04-02 Feb. 25, 2014 Feb. 24, 2015
Note: Calibration Interval of instruments listed above is one year.
Test Item Radiated Emission
Test Site 966 chamber 2 / (03CH02-WS)
Instrument Manufacturer Model No. Serial No. Calibration Date Calibration Until
Receiver R&S ESR3 101657 Jan. 18, 2014 Jan. 17, 2015
Bilog Antenna SCHWARZBECK VULB9168 VULB9168-524 Jan. 08, 2014 Jan. 07, 2015
Preamplifier Burgeon BPA-530 100218 Dec. 09, 2013 Dec. 08, 2014
LF cable 3M Woken CFD400NL-LW CFD400NL-003 Dec. 17, 2013 Dec. 16, 2014
LF cable 10M Woken CFD400NL-LW CFD400NL-004 Dec. 17, 2013 Dec. 16, 2014
Spectrum Analyzer R&S FSV40 101499 Feb. 08, 2014 Feb. 07, 2015
Horn Antenna 1G-18G
SCHWARZBECK BBHA 9120 D BBHA 9120 D 1095 Jan. 07, 2014 Jan. 06, 2015
Horn Antenna 18G-40G
SCHWARZBECK BBHA 9170 BBHA 9170517 Dec. 27, 2013 Dec. 26, 2014
Preamplifier Agilent 83017A MY39501309 Dec. 09, 2013 Dec. 08, 2014
Preamplifier EM EM18G40G 060572 Jun. 20, 2013 Jun. 19, 2014
RF Cable HUBER+SUHNER SUCOFLEX104 MY16140/4 Dec. 17, 2013 Dec. 16, 2014
RF Cable HUBER+SUHNER SUCOFLEX104 MY16018/4 Dec. 17, 2013 Dec. 16, 2014
RF Cable HUBER+SUHNER SUCOFLEX104 MY16015/4 Dec. 17, 2013 Dec. 16, 2014
Note: Calibration Interval of instruments listed above is one year.
Test Photos Report No. : FD331334-01
SPORTON INTERNATIONAL INC. Page No. : A1 of A4
TEL : 886-3-327-3456 Report Version : Rev. 01
FAX : 886-3-327-0973
Appendix A. TEST PHOTOS
1 Photographs of Conducted Emissions Test Configuration
FRONT VIEW
REAR VIEW
Test Photos Report No. : FD331334-01
SPORTON INTERNATIONAL INC. Page No. : A2 of A4
TEL : 886-3-327-3456 Report Version : Rev. 01
FAX : 886-3-327-0973
SIDE VIEW
Test Photos Report No. : FD331334-01
SPORTON INTERNATIONAL INC. Page No. : A3 of A4
TEL : 886-3-327-3456 Report Version : Rev. 01
FAX : 886-3-327-0973
2 Photographs of Radiated Emissions Test Configuration
For radiated emission below 1GHz
FRONT VIEW
REAR VIEW
Test Photos Report No. : FD331334-01
SPORTON INTERNATIONAL INC. Page No. : A4 of A4
TEL : 886-3-327-3456 Report Version : Rev. 01
FAX : 886-3-327-0973
For radiated emission above 1GHz
FRONT VIEW
REAR VIEW