8
Selectivity Accelerated Fase Stazionaria: Bifenilica Si CH 3 CH 3 O Innovative Chromatography Products www.superchrom.it Tel. +39 027610037 Fax +39 0270100100 mail: [email protected]

Fase Stazionaria: Bifenilicatemperatura massima: 80 C pressione massima: 600 Bar (8700 psi) Proprietà: •umento di ritenzione per analiti con momento dipolare, insaturi o A coniugati

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Fase Stazionaria: Bifenilicatemperatura massima: 80 C pressione massima: 600 Bar (8700 psi) Proprietà: •umento di ritenzione per analiti con momento dipolare, insaturi o A coniugati

Selectivity Accelerated

Fase Stazionaria:

Bifenilica SiCH3 CH3

O

Innovative Chromatography Products www.superchrom.it Tel. +39 027610037 Fax +39 0270100100 mail: [email protected]

Page 2: Fase Stazionaria: Bifenilicatemperatura massima: 80 C pressione massima: 600 Bar (8700 psi) Proprietà: •umento di ritenzione per analiti con momento dipolare, insaturi o A coniugati

2 www.restek.com/raptor Tel 027610037 oppure: [email protected]

SiCH3 CH3

O

Con le colonne Raptor, i chimici di Restek divennero i primi a combinare la velocità tipica delle fasi a particelle porose solo in superficie (anche note come SPP o particelle “core-shell”) con la risoluzione della tecnologia USLC® estremamente selettiva. Questa nuova tipologia di colonne cromatografiche permette di ottenere più facilmente la separazione dei picchi e tempi di analisi più rapidi senza una strumentazione costosa come UHPLC. La nostra priorità nello sviluppare la nuova linea di SPP era creare una versione innovativa della nostra Bifenilica (Biphenyl Column). La colonna Bifenilica, nostro prodotto di punta, è la fase stazionaria LC più famosa di Restek perché è particolarmente adatta a separare composti che sono difficili da risolvere o che eluiscono troppo velocemente con fase C18 o con altre fasi feniliche. Come si evince, la robusta colonna Raptor™ Biphenyl è estremamente versatile per separazioni veloci in applicazioni bioanalitiche come analisi di farmaci e di metaboliti, specialmente se richiedono uno spettrometro di massa (MS). L’aumento della ritenzione di composti eluiti velocemente può ridurre la soppressione ionica; l’aumento della selettività aiuta ad eliminare la necessità di utilizzare fasi mobili complesse non compatibili dalla spettrometria di massa.

Restek è stata la prima ad introdurre i vantaggi del ligando Bifenilico ed ha (inoltre) l’esperienza che consente di ottimizzare le prestazioni delle SPP in fase fenilica, per adattarle ai ritmi di lavoro odierni.

Colonne Raptor™ Bifeniliche

Tipologie di Interazioni:

Ultra Aqueous C18

Hydrophobic

Dipolar

Acidic

Basic

0 2 4 6 8 10

Ultra IBD

Hydrophobic

Dipolar

Acidic

Basic

0 2 4 6 8 10

Ultra Biphenyl

Hydrophobic

Dipolar

Acidic

Basic

0 2 4 6 8 10

Ultra PFP Propyl

Hydrophobic

Dipolar

Acidic

Basic

0 2 4 6 8 10

Ultra C18

Hydrophobic

Dipolar

Acidic

Basic

0 2 4 6 8 10

Categoria Fase:Fenilica (L11)

Tipo di Ligando: Bifenilico

Particolato: 2.7 µm silica superficilamente porosa(SPP o “core-shell”)

Dimensione Pori: 90 Å

Area Superficiale: 150 m2/g

Raccomandazioni d’uso:

pH range: 1.5-8.0

temperatura massima: 80°C

pressione massima: 600 Bar (8700 psi)

Proprietà:• Aumento di ritenzione per analiti con momento dipolare, insaturi o coniugati• Aumento di selettività se utilizzate con fase mobile metanolica• Ideale per aumentare sensibilità e selettività nelle analisi LC-MS

Quando scegliere una Bifenilica:• Bassa selettività su fase C18• Necessità di aumentare la ritenzione di composti aromatici idrofilici

Descrizione della Colonna:

Principali interazioni dei soluti:• Polarizzabilità• Dispersione

Interazioni secondarie dei soluti:• Scambio Cationico

Profilo delle interazioni:

Aqueous C18

IBD

Biphenyl

PFPP

Disp

ersion H-Bonding

Polarizability Cation Exchan

ge

Disp

ersion H-Bonding

Polarizability Cation Exchan

ge

Disp

ersion H-Bonding

Polarizability Cation Exchan

ge

Disp

ersion H-Bonding

Polarizability Cation Exchan

ge

Analiti verso cui è rivolta: • Aromatici• Dipolari

Gruppi funzionali verso cui è rivolta:• Aromatici idrofilici • Con forte momento dipolare• Acidi di Lewis • Composti dipolari, insaturi o coniugati• Composti policiclici con gruppi elettron-attrattori

Page 3: Fase Stazionaria: Bifenilicatemperatura massima: 80 C pressione massima: 600 Bar (8700 psi) Proprietà: •umento di ritenzione per analiti con momento dipolare, insaturi o A coniugati

Tel 027610037 oppure: [email protected] www.restek.com/raptor 3

Più selettività aromatica rispetto alle comuni fasi Phenyl-HexylLe colonne SPP core shell sono un’ottimizzazione delle tradizionali fasi stazionarie Phenyl-Hexyl, in più l’innovativo ligando bifenilico, sviluppato dai chimici Restek, è la nuova generazione della chimica delle colonne feniliche. Questa tipologia di ligando assicura una maggiore selettività aromatica rispetto alle colonne phenyl-hexyl disponibili in commercio e garantisce un maggior grado di dispersione rispetto alle comuni feniliche. Come è evidente, la Raptor Bifenilica permette di separare facilmente i composti bioanalitici, come gli aromatici (fig. 1 e 2), che eluiscono troppo presto o che sono difficili da separare con fasi C18 o altre fasi feniliche.[1] In-house testing based on: M. R. Euerby, P. Petersson, W. Campbell, W. Roe, Chromatographic classification and comparison of commercially available reversed-phase liquid chromato-graphic columns containing phenyl moieties using principal component analysis, J. Chromatogr. A 1154 (2007) 138–151.

Figura 1: Raptor™ Bifenilica evidenzia una maggiore selettività aromatica rispetto ad altre colonne SPP feniliche.

Figura 2: le Raptor™ Bifeniliche mostrano un aumento di ritenzione per composti contenenti gruppi elettron-attrattori. Sia il tempo di ritenzione che l’ordine di eluizione sono drasticamente diversi da una tradizionale colonna C18.

1

2

3 4

Time (min)0.00 1.00 2.00 3.00 4.00 5.00 6.00 7.00 8.00

LC_GN0546

Column: Raptor™ Biphenyl (cat.# 9309A55); Dimensions: 50 mm x 4.6 mm ID; Particle Size: 2.7 µm; Pore Size: 90 Å; Temp.: 40 °C; Sample: Diluent: acetonitrile; Conc.: 100-500 µg/mL; Inj. Vol.: 1 µL Mobile Phase: water: methanol (50:50); Flow: 1.2 mL/min; Detector: Waters Acquity® PDA @ 254 nm; Instrument: Waters Acquity® UPLC H-Class.

Conc. Peaks tR (min) (µg/mL) 1. Benzene 1.63 500 2. Nitrobenzene 2.09 100 3. 1,3,5-Trinitrobenzene 4.83 100 4. 2,4-Dinitrotoluene 5.35 100

0.00

0.50

1.00

1.50

2.00

2.50

3.00

TNB/NB DNT/NB TNB/DNT

Sele

ctiv

ity (α

)

Raptor™ Biphenyl

Ascentis® Express Phenyl-Hexyl

Kinetex® Phenyl-Hexyl

Raptor™ Biphenyl columns o�er the best resolutionfor aromatic selectivity probes.

DNT= 2,4-DinitrotolueneNB = NitrobenzeneTNB = 1,3,5-Trinitrobenzene

0.00

0.50

1.00

1.50

2.00

2.50

3.00

TNB/NB DNT/NB TNB/DNT

Sele

ctiv

ity (α

)

Raptor™ Biphenyl

Ascentis® Express Phenyl-Hexyl

Kinetex® Phenyl-Hexyl

Raptor™ Biphenyl columns o�er the best resolutionfor aromatic selectivity probes.

B = BenzeneDNT= 2,4-DinitrotolueneNB = NitrobenzeneTNB = 1,3,5-Trinitrobenzene

RESTEK® USLC®

Ultra Selective Liquid Chromatography

Per saperne di più in merito alla tecnologia ed alle fasi USLC® : www.restek.com/uslc

Incluse nel set di colonne USLC®!

Page 4: Fase Stazionaria: Bifenilicatemperatura massima: 80 C pressione massima: 600 Bar (8700 psi) Proprietà: •umento di ritenzione per analiti con momento dipolare, insaturi o A coniugati

4 www.restek.com/raptor Tel 027610037 oppure: [email protected]

Stabilità della Pressione:Uno dei maggiori vantaggi di una colonna SPP è la possibilità di ottenere separazioni veloci ed efficienti, operando a velocità lineari più elevate di quelle possibili con le colonne convenzionali con particelle totalmente porose. Tuttavia, queste velocità più elevate possono tradursi in pressioni maggiori. Le colonne Raptor sono state progettate per gestire l’aumento di pressione necessario per ottenere una Selettività Accelerata e lo fanno meglio di altre colonne SPP in commercio. (Fig.3)

Il nuovo standard di prestazione e resistenza per le colonne SPP Core-Shell

Riproducibilità:Al fine di aiutare a mantenere l’alta produttività a bassi costi nel tuo laboratorio, la colonna Raptor Bifenilica deve garantire eccezionale selettività e analisi veloci non una volta ma sempre. Robustezza e ripetibilità sono essenziali, motivo per cui ogni decisione finalizzata alla produzione di questa colonna, dalla tecnica di legame della silice al processo di impaccamento, alla tecnologia avanzata, è stata presa per assicurare una superlativa ripro-ducibilità da iniezione a iniezione (fig 4) e da lotto a lotto (fig 5). Abbiamo anche adottato delle nuove specifiche in controllo qualità (QC) per garantire la stabilità nei tempi di ritenzione, necessaria per effettuare analisi in MRM senza incovenienti.

Figura 3: Ad alte pressioni, le colonne concorrenti Phenyl-Hexyl, mostrano una rapida e netta caduta di efficienza ma le colonne Raptor™ Bifeniliche non risentono di questa problematica, per almeno 3000 iniezioni.

Figura 4: Anche dopo centinaia di iniezi-oni la colonna Raptor™ Bifenilica garantirà risultati costanti e affidabili

Figura 5: Da un lotto all’altro, ogni colonna Raptor™ Bifenilica garantirà le stesse prestazioni.

0.0 0.50 1.00 1.50 2.00 2.50 3.00 3.50 4.00Time (min)

Injection 500

Injection 1

LC_CF0565

Column: Raptor™ Biphenyl (cat.# 9309A1E); Dimensions: 100 mm x 3.0 mm ID; Particle Size: 2.7 µm; Pore Size: 90 Å; Temp.: 30 °C; Sample: Diluent: initial mobile phase; Conc.: 50 ng/mL; Inj. Vol.: 5 µL Mobile Phase: A: 0.1% formic acid in water, B: 0.1% formic acid in acetonitrile; Gradient (%B): 0.00 min (40%), 3.00 min (80%), 3.01 min (40%), 5.00 min (40%); Flow: 0.700 mL/min; Detector: Waters Xevo TQ-S; Ion Mode: ESI+; Instrument: Waters.

Peaks 1. Cortisol 2. 11-Deoxycortisol 3. Estradiol 4. Boldenone 5. Testosterone 6. Androstenedione 7. Progesterone

0.400

0.500

0.600

0.700

0.800

0.900

1.000

1.100

0 1000 2000 3000

% E�ciency vs # of InjectionsCompetitor 50 x 2.1 mm Phenyl-Hexyls @ 600 bar

Raptor™ Biphenyl 2.7 µm

Agilent Poroshell® 2.7 µm Phenyl-Hexyl 120 A

Supelco Ascentis® Express 2.7 µm Phenyl-Hexyl 90 A

0.0 0.50 1.00 1.50 2.00 2.50 3.00 3.50 4.00 4.50 5.00

Time (min)

Lot #1

Lot #2

Lot #3

Lot #4

Lot #5

LC_CF0562

Vedere fig 4 per l’elenco dei composti e condizioni

Page 5: Fase Stazionaria: Bifenilicatemperatura massima: 80 C pressione massima: 600 Bar (8700 psi) Proprietà: •umento di ritenzione per analiti con momento dipolare, insaturi o A coniugati

Tel 027610037 oppure: [email protected] www.restek.com/raptor 5

Figura 6: Raptor™ Bifeniliche permettono le analisi degli antidolorifici con una risoluzione isobarica completa in meno di 5 minuti!

Testata su applicazioni cliniche per ottimizzare i processi di lavoro Per circa un decennio, la Restek Bifenilica è stata la colonna di prima scelta per test clinici grazie alla sua capacità di garantire un’ elevata ritenzione, selettività e separazioni robuste in fase inversa di farmaci e metaboliti. Portando la velocità d’analisi propria delle SPP alla famiglia delle bifeniliche, la Raptor™ Bifenilica assicura ai laboratori clinici una più rapida opzione per un’ampia varietà di saggi clinici.

Classi di antidolorifici da campioni di urina in meno di 3,5 minutiLe classi di antidolorifici possono essere difficili da ottimizzare e riprodurre analiticamente a causa della limitata selettività delle fasi C18 e Phenyl-Hexyl , ma non con la Raptor™ Bifenilica. Usando le colonne Raptor™ Bifeniliche potrai eseguire l’analisi di antido-lorifici in 5 minuti e risolvere i composti con la stessa massa nominale. (fig.6). Le principali colonne concorrenti producono picchi scodati, lunghi tempi d’analisi e coeluizioni; solo la Raptor™ Bifenilica garantisce la selettività e le prestazioni necessarie per queste analisi complesse.

Time (min)

Time (min)

0.50.0 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0

3.0 3.52.52.0LC_CF0574

LC_CF0573

Column: Kinetex® Phenyl-Hexyl (cat.# 00B-4495-E0); Dimensions: 50 mm x 4.6 mm ID; Particle Size: 2.6 µm; Pore Size: 100 Å; Temp.: 22 °C; Sample: Diluent: urine:mobile phase A:mobile phase B (17:76:7); Conc.: 10-100 ng/mL; Inj. Vol.: 10 µL Mobile Phase: A: 10 mM ammonium formate in water, B: 0.1% formic acid in methanol; Gradient (%B): 0.00 min (5%), 4.00 min (100%), 5.00 min (100%), 5.10 min (5%), 7.00 min (5%); Flow: 0.6 mL/min; Detector: AB SCIEX API 4000™ MS/MS; Ion Source: TurboIonSpray®; Ion Mode: ESI+; Instrument: API LC-MS/MS; Notes: Lorazepam was prepared at 100 ng/mL; all other analytes are 10 ng/mL.

0.0 0.5 1.0

1.5 2.0

1.5 2.0 2.5 3.0 3.5 4.0

Time (min)

Time (min)LC_CF0568

Column: Raptor™ Biphenyl (cat.# 9309A5E); Dimensions: 50 mm x 3.0 mm ID; Particle Size: 2.7 µm; Pore Size: 90 Å; Temp.: 30 °C; Sample: Diluent: urine:mobile phase A:mobile phase B (17:76:7); Conc.: 10-100 ng/mL; Inj. Vol.: 10 µL Mobile Phase: A: 0.1% formic acid in water, B: 0.1% formic acid in methanol; Gradient (%B): 0.00 min (10%), 1.50 min (45%), 2.50 min (100%), 3.70 min (100%), 3.71 min (10%) 5.00 min (10%); Flow: 0.6 mL/min; Detector: AB SCIEX API 4000™ MS/MS; Ion Source: TurboIonSpray®; Ion Mode: ESI+; Instrument: API LC-MS/MS; Notes: Lorazepam was prepared at 100 ng/mL; all other analytes are 10 ng/mL.

Peaks tR (min) Precursor ion Product ion 1 Product ion 2 1. Morphine* 1.34 286.2 152.3 165.3 2. Oxymorphone 1.40 302.1 227.3 198.2 3. Hydromorphone* 1.52 286.1 185.3 128.2 4. Amphetamine 1.62 136.0 91.3 119.2 5. Methamphetamine 1.84 150.0 91.2 119.3 6. Codeine* 1.91 300.2 165.4 153.2 7. Oxycodone 2.02 316.1 241.3 256.4 8. Hydrocodone* 2.06 300.1 199.3 128.3 9. Norbuprenorphine 2.59 414.1 83.4 101.0 10. Meprobamate 2.61 219.0 158.4 97.2 11. Fentanyl 2.70 337.2 188.4 105.2 12. Buprenorphine 2.70 468.3 396.4 414.5 13. Flurazepam 2.73 388.2 315.2 288.3 14. Sufentanil 2.77 387.2 238.5 111.3 15. Methadone 2.86 310.2 265.3 105.3 16. Carisoprodol 2.87 261.2 176.3 158.1 17. Lorazepam 3.03 321.0 275.4 303.1 18. Diazepam 3.31 285.1 193.2 153.9 *An extracted ion chromatogram (XIC) of the isobars is presented in the inset.

0.50.0 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0

2.0 2.51.5Time (min)

Time (min)

LC_CF0578

LC_CF0577

Column: Kinetex® C18 (cat.# 00B-4462-Y0); Dimensions: 50 mm x 3.0 mm ID; Particle Size: 2.6 µm; Pore Size: 100 Å; Temp.: 25 °C; Sample: Diluent: urine:mobile phase A:mobile phase B (17:76:7); Conc.: 10-100 ng/mL; Inj. Vol.: 10 µL Mobile Phase: A: 10 mM ammonium formate in water, B: 0.1% formic acid in methanol; Gradient (%B): 0.00 min (5%), 3.00 min (100%), 4.00 min (100%), 4.10 min (5%), 5.00 min (5%); Flow: 0.5 mL/min; Detector: AB SCIEX API 4000™ MS/MS; Ion Source: TurboIonSpray®; Ion Mode: ESI+; Instrument: API LC-MS/MS; Notes: Lorazepam was prepared at 100 ng/mL; all other analytes are 10 ng/mL.

XIC di isobarici

Scarsa risoluzione e forma del picco per composti isobarici.

Coeluizione di più analiti e picchi scodati

XIC di isobarici

Più lunghi tempi d’analisi

Picchi scodati al termine dell’eluizione di composti isobarici

XIC di isobarici

Eccellente separazione di composti isobarici (stessa massa nominale).

Componenti della matrice (urina umana)

Analiti separati dalla prima fase d’analisi contenente la matrice

Kinetex® Phenyl-Hexyl Kinetex® C18

Raptor™ Biphenyl

Page 6: Fase Stazionaria: Bifenilicatemperatura massima: 80 C pressione massima: 600 Bar (8700 psi) Proprietà: •umento di ritenzione per analiti con momento dipolare, insaturi o A coniugati

6 www.restek.com/raptor Tel 027610037 oppure: [email protected]

Catecolamine e Fans senza l’utilizzo di coppia ionica, HILIC o fasi mobili complesseL’analisi in HPLC di analiti quali catecolamine può essere problematica e spesso costringe i chimici a orientarsi verso fasi mobili complesse, HILIC o con reagenti di coppia ionica che non sono compatibili con la spettrometria di massa (MS). Le colonne Rap-tor™ Bifeniliche trattengono facilmente e separano questi analiti problematici utilizzando fasi mobili semplici e compatibili con la spettrometria di massa (MS) in tempistiche tali da ottimizzare la produttività (fig 7). Raptor™ Bifenilica permette anche una rapida ed efficiente analisi dei FANS (farmaci antiinfiammatori non steroidei) con solventi compatibili con LC-MS (fig 8)

Figura 7: Separazione semplice e veloce di catecolamine e altri neurotrasmettitori senza l’utilizzo di coppia ionica o HILIC.

Figura 8: Anche i farmaci antiinfiammatori non steroidei (FANS) sono risolti con facilità mediante la Raptor™ Bifenilica, utilizzando fasi mobili compatibili con UV e MS.

1

2 3

4

5

6

7

8

9

10

Time (min)0.00 0.50 1.00 1.50 2.00 2.50 3.00 3.50 4.00

LC_CF0560

Column: Raptor™ Biphenyl (cat.# 9309A62); Dimensions: 150 mm x 2.1 mm ID; Particle Size: 2.7 µm; Pore Size: 90 Å; Temp.: 30 °C; Sample: Dilu-ent: water; Conc.: 50 µg/mL; Inj. Vol.: 1 µL Mobile Phase: A: 0.1% formic acid in water, B: 0.1% formic acid in acetonitrile; Gradient (%B): 0.00 min (0%), 4.00 min (70%), 4.01 min (0%), 5.00 min (0%); Flow: 0.4 mL/min; Detector: Waters Acquity® PDA @ 280 nm; Instrument: Waters Acquity® UPLC H-Class.

Peaks tR (min) 1. Norepinephrine 0.85 2. Epinephrine 1.11 3. L-Dihydroxyphenylalanine 1.21 4. Dopamine 1.40 5. Tyrosine 1.59 6. 3-Methoxytyramine* 2.33 7. Serotonin 2.38 8. (3,4-Dihydroxyphenyl)acetic acid* 2.79 9. 5-Hydroxyindoleacetic acid** 3.16 10. Homovanillic acid* 3.22 * Dopamine metabolite, ** serotonin metabolite

0.00 0.50 1.00 1.50

1

2

3 4

5

6

7

Time (min)

2.00 2.50 3.00 3.50 4.00

LC_CF0561

Column: Raptor™ Biphenyl (cat.# 9309A12); Dimensions: 100 mm x 2.1 mm ID; Particle Size: 2.7 µm; Pore Size: 90 Å; Temp.: 40 °C; Sample: Diluent: water:acetonitrile (65:35); Conc.: 25-200 µg/mL; Inj. Vol.: 2 µL Mobile Phase: A: 0.1% formic acid in water, B: 0.1% formic acid in acetonitrile; Gradient (%B): 0.00 min (35%), 4.00 min (60%), 4.01 min (35%), 5.00 min (35%); Flow: 0.6 mL/min; Detector: Waters Acquity® PDA @ 270 nm; Instrument: Waters Acquity® UPLC H-Class.

Peaks tR (min) Conc. (µg/mL) 1. Piroxicam 1.39 25 2. Sulindac 1.60 25 3. Naproxen 1.85 25 4. Fenoprofen 2.44 100 5. Ibuprofen 2.54 200 6. Diclofenac 2.96 25 7. Indomethacin 3.08 25

Page 7: Fase Stazionaria: Bifenilicatemperatura massima: 80 C pressione massima: 600 Bar (8700 psi) Proprietà: •umento di ritenzione per analiti con momento dipolare, insaturi o A coniugati

Tel 027610037 oppure: [email protected] www.restek.com/raptor 7

Analisi rapide e senza co-eluizioni di antibiotici solforatiNemmeno le fasi stazionarie ad alta efficienza UHPLC C18 e le comuni colonne feniliche riescono a garantire una separazione alla linea di base dei picchi dei sulfamidici. La Raptor™ Bifenilica possiede la selettività per separare facilmente e completamente questi composti problematici (fig 9) in meno di 5 minuti!

Figura 9: I sulfamidici non creano problemi analitici anche ad alte velocità lineari. L’aumento di ritenzione della sulfanilammide, composto eluito velocemente, riduce la soppressione ionica.

1

2

3

4

5

6

7

8

9

10

11

Time (min)

0.00 0.50 1.00 1.50 2.00 2.50 3.00 3.50 4.00 4.50

LC_FF0530

Column: Raptor™ Biphenyl (cat.# 9309A5E); Dimensions: 50 mm x 3.0 mm ID; Particle Size: 2.7 µm; Pore Size: 90 Å; Temp.: 20 °C; Sample: Diluent: 0.1% formic acid in water; Conc.: 50 µg/mL; Inj. Vol.: 5 µL Mobile Phase: A: 0.1% formic acid in water, B: 0.1% formic acid in acetonitrile; Gradient (%B): 0.00 min (5%), 2.00 min (10%), 4.50 min (35%), 4.51 min (5%), 5.50 min (5%); Flow: 1.5 mL/min; Detector: Waters Acquity® PDA @ 260, 4.8 nm; Instrument: Waters Acquity® UPLC H-Class.

Peaks tR(min) 1. Sulfanilamide 0.41 2. Sulfadiazine 1.59 3. Sulfapyridine 1.84 4. Sulfathiazole 1.96 5. Sulfamerazine 2.14 6. Sulfamethazine 2.71 7. Sulfachlorpyridazine 3.29 8. Sulfadoxine 3.44 9. Sulfisoxazole 3.58 10. Sulfadimethoxine 3.98 11. Sulfaquinoxaline 4.08

Coelution

Time (min)0.00 0.50 1.00 1.50 2.00 2.50 3.00 3.50 4.00 4.50

LC_FF0532

Column: Kinetex® C18 (cat.# 00B-4462-Y0); Dimensions: 50 mm x 3.0 mm ID; Particle Size: 2.6 µm; Pore Size: 100 Å; Temp.: 20 °C; Sample: Diluent: 0.1% formic acid in water; Conc.: 50 µg/mL; Inj. Vol.: 5 µL Mobile Phase: A: 0.1% formic acid in water, B: 0.1% formic acid in acetonitrile; Gradient (%B): 0.00 min (5%), 2.00 min (10%), 4.50 min (35%), 4.51 min (5%), 5.50 min (5%); Flow: 1.5 mL/min; Detector: Waters Acquity® PDA @ 260, 4.8 nm; Instrument: Waters Acquity® UPLC H-Class.

Peaks 1. Sulfanilamide 2. Sulfadiazine 3. Sulfapyridine 4. Sulfathiazole 5. Sulfamerazine 6. Sulfamethazine

7. Sulfachlorpyridazine 8. Sulfadoxine 9. Sulfisoxazole 10. Sulfadimethoxine 11. Sulfaquinoxaline

Time (min)

Coelution

0.00 0.50 1.00 1.50 2.00 2.50 3.00 3.50 4.00 4.50

LC_FF0536

Column: Acquity® CSH™ Phenyl-Hexyl (cat.# 186005406); Dimensions: 50 mm x 2.1 mm ID; Particle Size: 1.7 µm; Temp.: 20 °C; Sample: Diluent: 0.1% formic acid in water; Conc.: 50 µg/mL; Inj. Vol.: 5 µL Mobile Phase: A: 0.1% formic acid in water, B: 0.1% formic acid in acetonitrile; Gradient (%B): 0.00 min (5%), 2.00 min (10%), 4.50 min (35%), 4.51 min (5%), 5.50 min (5%); Flow: 0.75 mL/min; Detector: Waters Acquity® PDA @ 260, 4.8 nm; Instrument: Waters Acquity® UPLC H-Class.

Peaks 1. Sulfanilamide 2. Sulfadiazine 3. Sulfapyridine 4. Sulfathiazole 5. Sulfamerazine 6. Sulfamethazine

7. Sulfachlorpyridazine 8. Sulfadoxine 9. Sulfisoxazole 10. Sulfadimethoxine 11. Sulfaquinoxaline

Acquity® CSH™ Phenyl-HexylKinetex® C18

Raptor™ Biphenyl

Page 8: Fase Stazionaria: Bifenilicatemperatura massima: 80 C pressione massima: 600 Bar (8700 psi) Proprietà: •umento di ritenzione per analiti con momento dipolare, insaturi o A coniugati

Cartucce precolonne Raptor™ EXP® Colonne LC Raptor™Bifeniliche

Fitting manuale —Non servono chiavi!

Cartuccia precolonna unidirezianle Raptor™

EXP®

Holder

Ferula ibrida in titanio Autoregolante a

connessione ZDV!

Hybrid Ferrule U.S. Patent No. 8201854, Optimize Technologies. Optimize Technologies EXP Holders are Patent Pending. Other U.S. and Foreign Patents Pending. The EXP, Free-Turn, and the Opti- prefix are registered trademarks of Optimize Technologies, Inc.

www.restek.com/raptor

Lit. Cat.# GNBR1891-RIS© 2013 Restek Corporation. All rights reserved.

Printed in the U.S.A.

2.1 mm 3.0 mm 4.6 mmLunghezza cat.# cat.# cat.#30 mm 9309A32 9309A3E 9309A35 50 mm 9309A52 9309A5E 9309A55 100 mm 9309A12 9309A1E 9309A15 150 mm 9309A62 9309A6E 9309A65

Holder EXP® Direct Connect Descrizione qty. cat.#EXP Direct Connect Holder (includes hex-head fitting & 2 ferrules) ea. 25808

Cartucce precolonne Raptor™ EXP®

EXP®Fittings riutilizzabili per HPLC & UHPLC per fittings10-32 e tubi da 1/16"

• La tipologia di connettore ad avvita-mento manuale consente una tenuta semplice dell’HPLC senza la necessità di strumenti fino a 8700 psi.

• Entrambe le tipologie, ad avvitamento manuale e mediante chiave per un uso affidabile in UHPLC fino a 20000+ psi

• Ferrule brevettate possono essere installate ripetutamente senza compromettere la tenuta ad alte pressioni.

• Il modello ibrido permette di combinare la resistenza del titanio con la capacità di tenuta del Peek .

• Sistemi all’avanguardia che permettono connessioni a volume morto nullo (ZDV) con qualsiasi connettore femmina 10-32.

• Compatibili con Peek 1/16 e capillari in acciaio inossidabile

Descrizione qty. cat.#EXP Hand-Tight Fitting (Nut w/Ferrule) ea. 25937 EXP Hand-Tight Fitting (Nut w/Ferrule) 10-pk. 25938 EXP Hand-Tight Nut (w/o Ferrule) ea. 25939

PATENTS & TRADEMARKSRestek® patents and trademarks are the property of Restek Corporation. (See www.restek.com/Patents-Trademarks for full list.) Other trademarks appearing in Restek® literature or on its website are the property of their respective owners. The Restek® registered trademarks used here are registered in the United States and may also be registered in other countries.

Descrizione Particle Size Size qty. cat.#Raptor Biphenyl EXP Guard Column Cartridge 2.7 µm 5 x 2.1 mm 3-pk. 9309A0252 Raptor Biphenyl EXP Guard Column Cartridge 2.7 µm 5 x 3.0 mm 3-pk. 9309A0253 Raptor Biphenyl EXP Guard Column Cartridge 2.7 µm 5 x 4.6 mm 3-pk. 9309A0250

Via Ciro Menotti 11 20129 - MilanoTelefono 027610037 Fax 0270100100 Mail: [email protected]

Per aiutare a proteggere il tuo investimento e per prolungare la vita delle nostre già robuste colonne LC, Restek offre precolonne sviluppate da Optimize Technologies (in attesa di brevetto). La cartuccia precolonna Restek direttamente connessa con l’holder EXP è l’ultima novità in ambito di protezione.

• L’architettura Free-Turn permette di cambiare manualmente le cartucce, senza interrompere le connessioni e senza l’utilizzo di strumenti.

• Le ferrule ibride brevettate, in titanio, possono essere installate ripetutamente, senza generare variazioni di pressione.

• Il modello autoregolante garantisce una connessione ZDV (volume morto nullo) con qualsiasi connettore femmina 10-32.

• Le cartucce precolonna richiedono un vano per connessione diretta EXP (cat. # 25808).

• Uniscilo a EXP hand-Tight Fitting (cat.#25937-25939) senza l’utilizzo di strumenti.