A.1 ASHRAE HANDBOOK Additions and Corrections This report includes additional information, and technical errors found between June 15, 2010, and April 1, 2013, in the inch-pound (I-P) editions of the 2010, 2011, and 2012 ASHRAE Handbook volumes. Occasional typographical errors and nonstandard symbol labels will be corrected in future volumes. The most current list of Handbook additions and corrections is on the ASHRAE web site (www.ashrae.org ). The authors and editor encourage you to notify them if you find other technical errors. Please send corrections to: Handbook Editor, ASHRAE, 1791 Tullie Circle NE, Atlanta, GA 30329, or e-mail [email protected] . 2010 Refrigeration Ch. 1. All existing references to Table 19 should be to Table 20. All existing references to Table 20 should be to Table 19. p. 10.4, Table 3. Replace the table with the following. p. 11.23, Table 2. Amend the table values as shown above right. p. 19.2, Eq. (4). Change t wo to x wo . p. 19.7, Eq. (10). Change t o t to (t o t) 2 . p. 50.4, Horsepower entry. The value for horsepower should be 550 ft·lb f /s 2 , not 500. 2011 HVAC Applications (CD only) Table of Contents, p. 2. Replace the second instance of “Building Operations and Management” with “General Applica- tions.” Contributors List. For Chapter 4, add Dennis Wessel, Karpinski Engineering. p. 28.8, 1st col. Under U.S. Evolutionary Power Reactor (USEPR), delete “(30 Pa).” p. 35.4, end of 2nd para. It should be = for all conditions. p. 35.5, Eq. (17). The equation should be F sg = (1 – cos )/2. p. 35.10, 2nd col., 3rd para. from bottom. The slope should be –0.82 /0.69 = –1.19. p. 35.22, Example 7, Solution. The load collector ratio should use Eq. (41). p. 35.23, 2nd col., last para. The average wind load on a tilted roof should be 25 lb/ft 2 . p. 35.27, Symbols. Delete the second definition for A ap . p. 36.9, Table 4. Replace the table with the one on p. A.3. p. 48.20, 2nd col. For frequency range #1, consult Table 13 for A f . In definitions for Eq. (10), refer to Table 12 for a . p. 48.45, Table 47. Deflection values for cooling towers should be Table 3 Cellular Glass Insulation Thickness for Indoor Design Conditions (90°F Ambient Temperature, 80% Relative Humidity, 0.9 Emittance, 0 mph Wind Velocity) (2010 Refrigeration, Chapter 10, p. 4) Nominal Pipe Size, in. Pipe Operating Temperature, °F 40 20 0 20 40 60 80 100 0.50 1.0 1.0 1.5 1.5 2.0 2.0 2.0 2.5 0.75 1.0 1.5 1.5 2.0 2.0 2.0 2.5 2.5 1.00 1.0 1.5 1.5 2.0 2.0 2.0 2.5 2.5 1.50 1.0 1.5 1.5 2.0 2.5 2.5 3.0 3.0 2.00 1.0 1.5 1.5 2.0 2.5 2.5 3.0 3.0 2.50 1.0 1.5 2.0 2.5 2.5 3.0 3.0 3.0 3.00 1.0 1.5 2.0 2.5 2.5 3.0 3.0 3.0 4.00 1.0 1.5 2.0 2.5 2.5 3.0 3.0 3.5 5.00 1.5 1.5 2.0 2.5 2.5 3.0 3.0 3.5 6.00 1.5 2.0 2.0 2.5 3.0 3.0 3.5 3.5 8.00 1.5 2.0 2.0 2.5 3.0 3.0 3.5 3.5 10.00 1.5 2.0 2.0 2.5 3.0 3.5 3.5 4.0 12.00 1.5 2.0 2.0 2.5 3.0 3.5 3.5 4.0 14.00 1.5 2.0 2.5 3.0 3.0 3.5 4.0 4.0 16.00 1.5 2.0 2.5 3.0 3.5 3.5 4.0 4.5 18.00 1.5 2.0 2.5 3.0 3.5 3.5 4.0 4.5 20.00 1.5 2.0 2.5 3.0 3.5 3.5 4.0 4.5 24.00 1.5 2.0 2.5 3.0 3.5 4.0 4.0 4.5 28.00 1.5 2.0 2.5 3.0 3.5 4.0 4.0 4.5 30.00 1.5 2.0 2.5 3.0 3.5 4.0 4.0 4.5 36.00 1.5 2.0 2.5 3.0 3.5 4.0 4.5 4.5 Notes: 1. Insulation thickness is chosen either to prevent or minimize condensation on outside jacket surface or to limit heat gain to 8 Btu/h·ft 2 , whichever thickness is greater. 2. All thicknesses are in inches. 3. Values do not include safety or aging factor. Actual operating conditions may vary. Consult a design engineer for appropriate recommendation for your specific system. 4. Data calculated using NAIMA 3E Plus program. Table 2 Values (2010 Refrigeration, Chapter 11, p. 23) Refrigerant f On the low side of a limited-charge cascade system: R-13, R-13B1, R-503 2.0 (0.163) R-14 2.5 (0.203) R-23, R-170, R-508A, R-508B, R-744, R-1150 1.0 (0.082) Other applications: R-11, R-32, R-113, R-123, R-142b, R-152a, R-290, R- 600, R-600a, R-764 1.0 (0.082) R-12, R-22, R-114, R-124, R-134a, R-401A, R-401B, R-401C, R-405A, R-406A, R-407C, R-407D, R-407E, R-409A, R-409B, R-411A, R-411B, R-411C, R-412A, R-414A, R-414B, R-500, R-1270 (0.131) R-115, R-402A, R-403B, R-404A, R-407B, R-410A, R-410B, R-502, R-507A, R-509A 2.5 (0.203) R-143a, R-402B, R-403A, R-407A, R-408A, R-413A 2.0 (0.163) R-717 0.5 (0.041) R-718 0.2 (0.016) Equipment Type Slab on Grade Floor Span Up to 20 ft 20 to 30 ft 30 to 40 ft Cooling Towers 0.25 3.5 3.5 3.5 0.25 2.5 2.5 2.5 0.25 0.75 0.75 1.5 Copyright © 2013, ASHRAE Licensed for single user. © 2013 ASHRAE, Inc. This file is licensed to Rabee Taleb ([email protected]). Publication Date: 6/1/2013

F13Additw erweronsI P

Embed Size (px)

DESCRIPTION

werwerwerwe

Citation preview

Page 1: F13Additw erweronsI P

Copyright © 2013, ASHRAE

Lice

nsed

for s

ingl

e us

er. ©

201

3 A

SH

RA

E, I

nc.

This file is licensed to Rabee Taleb ([email protected]). Publication Date: 6/1/2013

ASHRAE HANDBOOK

Additions and Corrections

This report includes additional information, and technical errorsfound between June 15, 2010, and April 1, 2013, in the inch-pound(I-P) editions of the 2010, 2011, and 2012 ASHRAE Handbookvolumes. Occasional typographical errors and nonstandard symbollabels will be corrected in future volumes. The most current list ofHandbook additions and corrections is on the ASHRAE web site(www.ashrae.org).

The authors and editor encourage you to notify them if youfind other technical errors. Please send corrections to: HandbookEditor, ASHRAE, 1791 Tullie Circle NE, Atlanta, GA 30329, ore-mail [email protected].

2010 Refrigeration

Ch. 1. All existing references to Table 19 should be to Table 20. Allexisting references to Table 20 should be to Table 19.

p. 10.4, Table 3. Replace the table with the following.

p. 11.23, Table 2. Amend the table values as shown above right.

p. 19.2, Eq. (4). Change two to xwo.

p. 19.7, Eq. (10). Change to – t to (to – t)2.

Table 3 Cellular Glass Insulation Thickness for Indoor Design Conditions

(90°F Ambient Temperature, 80% Relative Humidity, 0.9 Emittance, 0 mph Wind Velocity)

(2010 Refrigeration, Chapter 10, p. 4)

NominalPipe Size,

in.

Pipe Operating Temperature, °F

40 20 0 –20 –40 –60 –80 –100

0.50 1.0 1.0 1.5 1.5 2.0 2.0 2.0 2.50.75 1.0 1.5 1.5 2.0 2.0 2.0 2.5 2.51.00 1.0 1.5 1.5 2.0 2.0 2.0 2.5 2.51.50 1.0 1.5 1.5 2.0 2.5 2.5 3.0 3.02.00 1.0 1.5 1.5 2.0 2.5 2.5 3.0 3.02.50 1.0 1.5 2.0 2.5 2.5 3.0 3.0 3.03.00 1.0 1.5 2.0 2.5 2.5 3.0 3.0 3.04.00 1.0 1.5 2.0 2.5 2.5 3.0 3.0 3.55.00 1.5 1.5 2.0 2.5 2.5 3.0 3.0 3.56.00 1.5 2.0 2.0 2.5 3.0 3.0 3.5 3.58.00 1.5 2.0 2.0 2.5 3.0 3.0 3.5 3.5

10.00 1.5 2.0 2.0 2.5 3.0 3.5 3.5 4.012.00 1.5 2.0 2.0 2.5 3.0 3.5 3.5 4.014.00 1.5 2.0 2.5 3.0 3.0 3.5 4.0 4.016.00 1.5 2.0 2.5 3.0 3.5 3.5 4.0 4.518.00 1.5 2.0 2.5 3.0 3.5 3.5 4.0 4.520.00 1.5 2.0 2.5 3.0 3.5 3.5 4.0 4.524.00 1.5 2.0 2.5 3.0 3.5 4.0 4.0 4.528.00 1.5 2.0 2.5 3.0 3.5 4.0 4.0 4.530.00 1.5 2.0 2.5 3.0 3.5 4.0 4.0 4.536.00 1.5 2.0 2.5 3.0 3.5 4.0 4.5 4.5

Notes:1. Insulation thickness is chosen either to prevent or minimize condensation on outside

jacket surface or to limit heat gain to 8 Btu/h·ft2, whichever thickness is greater.2. All thicknesses are in inches.3. Values do not include safety or aging factor. Actual operating conditions may vary.

Consult a design engineer for appropriate recommendation for your specific system.4. Data calculated using NAIMA 3E Plus program.

A

p. 50.4, Horsepower entry. The value for horsepower should be550 ft·lbf /s2, not 500.

2011 HVAC Applications(CD only) Table of Contents, p. 2. Replace the second instance of“Building Operations and Management” with “General Applica-tions.”

Contributors List. For Chapter 4, add Dennis Wessel, KarpinskiEngineering.

p. 28.8, 1st col. Under U.S. Evolutionary Power Reactor (USEPR),delete “(30 Pa).”

p. 35.4, end of 2nd para. It should be = for all conditions.

p. 35.5, Eq. (17). The equation should be Fsg = (1 – cos ) /2.

p. 35.10, 2nd col., 3rd para. from bottom. The slope should be–0.82/0.69 = –1.19.

p. 35.22, Example 7, Solution. The load collector ratio should useEq. (41).

p. 35.23, 2nd col., last para. The average wind load on a tiltedroof should be 25 lb/ft2.

p. 35.27, Symbols. Delete the second definition for Aap.

p. 36.9, Table 4. Replace the table with the one on p. A.3.

p. 48.20, 2nd col. For frequency range #1, consult Table 13 for A f.In definitions for Eq. (10), refer to Table 12 for a .

p. 48.45, Table 47. Deflection values for cooling towers should be

Table 2 Values(2010 Refrigeration, Chapter 11, p. 23)

Refrigerant f

On the low side of a limited-charge cascade system:R-13, R-13B1, R-503 2.0 (0.163)R-14 2.5 (0.203)R-23, R-170, R-508A, R-508B, R-744, R-1150 1.0 (0.082)

Other applications:R-11, R-32, R-113, R-123, R-142b, R-152a, R-290, R-

600, R-600a, R-7641.0 (0.082)

R-12, R-22, R-114, R-124, R-134a, R-401A, R-401B, R-401C, R-405A, R-406A, R-407C, R-407D, R-407E, R-409A, R-409B, R-411A, R-411B, R-411C, R-412A, R-414A, R-414B, R-500, R-1270

(0.131)

R-115, R-402A, R-403B, R-404A, R-407B, R-410A, R-410B, R-502, R-507A, R-509A

2.5 (0.203)

R-143a, R-402B, R-403A, R-407A, R-408A, R-413A 2.0 (0.163)R-717 0.5 (0.041)R-718 0.2 (0.016)

Equipment TypeSlab on Grade

Floor Span

Up to 20 ft 20 to 30 ft 30 to 40 ft

Cooling Towers 0.25 3.5 3.5 3.50.25 2.5 2.5 2.50.25 0.75 0.75 1.5

.1

Page 2: F13Additw erweronsI P

A.2 2010–2012 ASHRAE Handbook Additions and Corrections

Lice

nsed

for s

ingl

e us

er. ©

201

3 A

SH

RA

E, I

nc.

This file is licensed to Rabee Taleb ([email protected]). Publication Date: 6/1/2013

p. 51.2, Eq. (10). Change Ta to Ta.

pp. 55.12-13, Eqs. (27), (28), (30), and (31). For all four equations,the denominators of the last two terms should be b and a, not 2b and2a. Also, for Eq. (31), change the first + sign to a – sign.

p. 60.9, Fig. 9. Replace the figure with the one above left.

Fig. 9 Typical Layout of UVGI Fixtures for Patient Isolation Room

(First et al. 1999)(2011 HVAC Applications, Ch. 60, p. 9)

2012 HVAC Systems and Equipment

p. 26.12, Example 2. Flow rate for ethylene glycol should be ingpm.

p. 41.3, Fig. 3. Replace parts B and C of the graphic with the hori-zontal polymer tube shown above right.

p. 44.8, Table 1. In both equations for flow and head, change theminuses to equals signs.

Fig. 3 Indirect Evaporative Cooling (IEC) Heat Exchanger(Courtesy Munters/Des Champs)

(2012 HVAC Systems and Equipment, Ch. 41, p. 3. Replaces only parts B and C of Fig. 3.)

Page 3: F13Additw erweronsI P

2010–2012 ASHRAE Handbook Additions and Corrections A.3

Lice

nsed

for s

ingl

e us

er. ©

201

3 A

SH

RA

E, I

nc.

This file is licensed to Rabee Taleb ([email protected]). Publication Date: 6/1/2013

Table 4 Energy Cost Percentiles from 2003 Commercial Survey(2011 HVAC Applications, Chapter 36, p. 9)

Building Use

Weighted Energy Cost Values, $/yr per gross square foot

Percentiles

Mean10th 25th 50th 75th 90th

Administrative/professional office 0.50 0.82 1.36 1.92 2.58 1.55Bank/other financial 1.09 1.37 2.00 2.93 4.47 2.41Clinic/other outpatient health 0.61 0.87 1.53 2.03 4.13 1.74College/university 0.44 1.20 1.37 2.27 $3.01 1.82Convenience store 2.48 3.75 5.26 8.02 10.12 6.17Convenience store with gas station 1.99 2.75 4.61 6.83 8.74 5.12Distribution/shipping center 0.24 0.33 0.54 0.88 1.37 0.74Dormitory/fraternity/sorority 0.58 0.69 0.87 1.29 2.13 1.07Elementary/middle school 0.54 0.78 1.09 1.57 2.60 1.48Entertainment/culture 0.14 0.42 0.56 2.25 17.82 2.83Fast food 2.93 4.98 8.87 12.29 14.14 8.92Fire station/police station 0.10 0.53 1.15 1.73 2.83 1.31Government office 0.52 0.90 1.40 1.88 2.66 1.52Grocery store/food market 2.60 3.07 4.31 5.27 6.85 4.84High school 0.60 0.87 1.02 1.60 2.19 1.30Hospital/inpatient health 1.37 2.16 2.46 3.17 3.55 2.70Hotel 0.74 1.05 1.33 1.76 2.52 1.58Laboratory 1.34 3.09 4.52 7.64 10.81 5.18Library 0.78 1.06 1.37 2.41 2.92 1.68Medical office (diagnostic) 0.33 0.68 1.02 2.13 2.53 1.33Medical office (nondiagnostic) 0.58 0.79 1.06 1.44 1.92 1.15Mixed-use office 0.46 0.85 1.30 1.96 2.90 1.78Motel or inn 0.49 0.83 1.21 1.82 2.67 1.48Nonrefrigerated warehouse 0.06 0.17 0.38 0.80 1.43 0.61Nursing home/assisted living 0.73 1.12 1.52 2.47 2.99 1.78Other 0.15 0.51 0.93 1.81 2.41 1.35Other classroom education 0.21 0.50 0.92 1.26 2.14 0.96Other food sales 0.60 0.72 0.95 2.35 6.02 2.20Other food service 0.79 1.60 2.44 6.50 11.56 4.72Other lodging 0.55 0.56 1.13 1.71 2.76 1.30Other office 0.37 0.71 1.19 2.16 2.56 1.47Other public assembly 0.35 0.50 0.81 1.56 2.06 1.15Other public order and safety 1.00 1.13 1.56 3.38 4.74 2.06Other retail 0.97 1.19 1.59 2.98 5.60 2.43Other service 0.76 1.13 1.58 2.92 7.29 2.71Post office/postal center 0.32 0.78 1.09 1.44 1.89 1.07Preschool/daycare 0.46 0.77 1.09 1.57 2.63 1.30Recreation 0.30 0.53 0.87 1.38 2.33 1.14Refrigerated warehouse 0.38 0.38 2.21 4.00 5.25 2.45Religious worship 0.25 0.37 0.60 0.84 1.32 0.72Repair shop 0.20 0.35 0.61 1.15 1.47 0.75Restaurant/cafeteria 1.12 1.86 3.33 7.44 10.48 4.80Retail store 0.36 0.53 0.98 1.77 2.90 1.38Self-storage 0.05 0.10 0.20 0.27 0.52 0.23Social/meeting 0.19 0.33 0.66 1.02 2.27 0.89Vacant 0.04 0.08 0.27 0.70 1.19 0.48Vehicle dealership/showroom 0.67 0.89 1.37 2.97 3.98 2.07Vehicle service/repair shop 0.29 0.50 0.77 1.38 2.07 1.10Vehicle storage/maintenance 0.04 0.16 0.48 1.12 1.96 0.83 SUM or Mean for sector 0.26 0.54 1.06 2.00 3.93 1.80

Source: Calculated based on DOE/EIA preliminary 2003 CBECS microdata.