External Alarm Installation Smart Pack Configuration Guide Outdoor Air Con Fan Cooled Cabinets

Embed Size (px)

Citation preview

EXTERNAL ALARM INSTALLATION &SMART PACK CONFIGURATION GUIDE(OUTDOOR AC/FAN COOLED SITE) EXTERNAL ALARM INSTALLATION GUIDE(OUTDOOR SITE) LIST OF ALARMSAlarm No. 1 : Rectifier & BTS Cabinet Door AlarmAlarm No. 2 : Rectifier Major AlarmAlarm No. 3 : Rectifier Minor AlarmAlarm No. 4 : Low DC VoltageAlarm No. 5 : Heat Management Alarm(For AirConCabinet Only)Alarm No. 7 : Temperature Alarm(For FanCool CabinetOnly) COLOR CODING of ALARMSAlarm No. 1 : Green & White GreenAlarm No. 2 : Blue & White BlueAlarm No. 3 : Violet and White VioletAlarm No. 4 : Grey & White GreyAlarm No. 5 : Black/Blue & Blue/BlackAlarm No. 7 : Light Blue & Light Blue/Black REQUIRED MATERIALAlarm CableKroneRackCAT-5 cable 7-9 metersSoldering IronOther basic tools OVERVIEWAlarm Cable is very long, so cut it in to 2 pieces1cable will be used for taking Alarms from Rectifier Smart Pack I/Ostports to Krone2Cable with connector at one end will be used for taking Alarmsndfrom Krone to BTS EAC port (2G Cabinet) STEP 1: KRONE INSTALLATIONInstall the Krone on the Rack and fix this rack in the rectifier cabinetas shown in the next slideUse proper size bolts and washer and should be tightenSee the picture in next slide I STEP 2: ALARM CABLE INSTALLATION (BTS --- Krone)Connect the Alarm cable connector on EAC port at BTS (2GCabinet)Bring the other end of Alarm cable to Rectifier through the RoxtecPunch the Alarm cable on the lower side of Krone according to theAlarms sequence i.e. 1,2,3,4 (Left to Right)The alarm cable should be fixed properly with ties and properlyroutedSee picture in next slide IMPORTANTAll the rest of the alarms which are not used must be looped as shown above in thepicture. There are total of 10 spaces in the Krone for the alarms Patching so to make aloop for Alarm# 11 (Genset Failure) & Alarm# 12 (Genset Low Fuel) we just twist thecables from the end to each other separately(Should be Soldered)& tape them nicely(Dont Hang Them) STEP 3: INSTALLATION ON THE RECTIFIER CHIPSUse the other piece of Alarm cable and punch it on the upper side ofKrone according to Alarms Sequence i.e. 1,2,3,4 (L to R) STEP 3Route this cable properly with ties and fix it near the Rectifier I/OportsConnect Green & White Green (Alarm nu 1) with Pins 8 & 9 of CON1(X1)Connect Grey & White Grey (Alarm nu 4) with Pins 9 & 10 of CON2(X2)Connect Violet & White Violet (Alarm nu 3) with Pins 15 & 16 ofCON2 (X2)Connect Blue & White Blue (Alarm nu 2) with Pins 18 & 19 of CON2(X2)Connect Light Blue & Light Blue Black (Alarm nu 7) with Pins 12 & 13of CON2 (X2)(Only for Fan Cool Rectifier Cabinets) CON 2(X2)CON 1(X1) HEAT MANAGEMENT ALARMAir condition in the door usuallyhas Red & Yellow cable for AirCondition AlarmThis cable is connected to Pins 3& 4 on CON1Remove this cable from there &punch it on KroneAir Con Alarm cable HEAT MANAGEMENT ALARMRemove this cable from pins & punch it on Krone as shownAir Con Alarm cable TESTING HEAT MANAGEMENT ALARMTo test Heat Management Alarm cover the AC from outside with plasticso that no air can go through as shown belowAir Condition covered with plastic sheet STEP 4: 900 BTS CABINET DOOR SENSORThe BTS Cabinet door sensor cable is verysmall so we have to extend itTake 1 pair from CAT-5 Cable and solderit with the sensor wires in BTS (900Cabinet)Route this cable properly and fix it nearSmart Pack I/O portsConnect this pair with pins 3 & 4 ofCON 2BTS Cabinet doorSensor STEP 4: 1800 BTS CABINET DOOR SENSOR(If Applicable)The BTS Cabinet door sensor cable is verysmall so we have to extend itTake 1 pair from CAT-5 Cable and solderit with the sensor wires in BTS (1800Cabinet)Route this cable properly and fix it nearSmart Pack I/O portsConnect this pair with pins 5 & 6 ofCON 2BTS Cabinet doorSensor STEP 5: RECTIFIER CABINET DOOR SENSORUsually Rectifier door Sensor cables are already connected to theCON 1 (X1)If it is not connected then connect Rectifier Door Alarm Cable withpins 1 & 2 of CON 1 (X1)Rectifier Door SensorRectifier Door cable connected topins 1 & 2 of CON 1 SMARTPACK CONFIGURATION GUIDE(OUTDOOR RECTIFIER.) REQUIRED MATERIALEltek Power Suite (This is easily available in CD with manualpresent at sites)PCCable for connection between PC and Smart pack (This cable isalso found at sites) OVERVIEWAll the Alarm configuration is already done & saved as a AlarmConfiguration file, except the configuration for Door (Rectifier & BTS)Alarm (Alarm# 1) which needs to be configured as followsWe will assign Alarm Output 2 for the output of Door Alarm (AlarmNo. 1)We will use Digital Inputs 1 (pins 1&2,CON1/X1), Digital Input 4 (pins3&4,CON2/X2 ) & (pins 5&6 of CON2) for Rectifier BTS900 and BTS1800 (if applicable) cabinet door respectively. STEP 1: INSTALLATION OF SOFTWAREInstall the Eltek Power Suite software properly in your PCInstall the drivers which are also available in CD STEP 2: CONNECTING TO SMART PACKConnect the data cable to your PC and Smart PackRun the software from the Icon on your desktopYou will see the window which is next slide When this window appears press the ConnectButton If you have installed the drivers correctly then press Find COM port #Button. You will get a COM port number hereEnter this port # hereSet Bits per Second to 38400 or 9600Password is 3Press the Connect button When you are connected you will see this windowDouble- click on Control Unit 1 Go to Alarm Group Configuration Tab Check this box infront of Door Alarm.All other checkboxes should be Un-CheckedIf you dont findany DoorAlarm writtenunder theAlarm Groupcolumn thenyou can editone of thesevacant AlarmUncheck all the Checked boxes under the column Alarm Output2Group andNow try to find door alarm written in the column Alarm Groupwrite DoorIf it is not there then edit any Alarm Group which is free and write there DoorAlarmAlarmCheck the Alarm Output2 in front of Door AlarmPress Apply at the bottomAfter this Click the Input Handler Tab You will Click the Door open linkIf it is not there then just click the First Link and make the settings asshown in the next slide Make sure Enable is checkedGive 3 sec Time delayChange the description, put it Rectifier Door and press ChangeGo to the Alarm Group Scroll bar and select Door AlarmPress OK Now press the ProgInput 1.4 link In the description write 900 Door and press changeOther settings are same as in 2 slides backPress OK Now press the ProgInput 1.5 link In the description write 1800 Door and press changeOther settings are same as in 4 slides backPress OK TEMPERATURE ALARM SETTINGS FOR FAN COOLRECTIFIER CABINET ONLYCheck this box infront of temperaturein alarm output4. Allother check boxesshould be Un-CheckedIf there is notemperaturealarm writtenunder theAlarm Groupcolumn then,edit one ofthese vacantAlarm Groupand writeTemperature TEMPERATURE ALARM SETTINGS FORFAN COOL RECTIFIER CABINET ONLYDouble click on thetemperature inPower Explorerunder Battery BankThis windowwill appearafter clickingtheTemperature inthe PowerExplorer. TEMPERATURE ALARM SETTINGS FORFAN COOL RECTIFIER CABINET ONLYClick on the BatteryTemp 1.1This windowwill appearafter clickingthe Batterytemp1.1 in thesmall extensionwindow TEMPERATURE ALARM SETTINGS FORFAN COOL RECTIFIER CABINET ONLYIn the alarm groupselect theTemperature for andadjust the Scales.Now apply the settings aspermanent. SPECIAL INSTRUCTIONSThe pictures which are pasted in slidesSHOULDNTbe considered as model pictures,because this installation was done by an Engineer without proper tools andequipmentConnect the Alarm cable connector on EAC port at2G BTS Cabinet (Important)So who so ever will install the Alarm cable mustinstall it properlyand with goodqualityCables should befixed and tiedproperlyThere should beno lose connectionson the I/O pinsThe sensor cable which is to be extendedmust be solderedproperly and coveredproperly with tapePatching on KroneSHOULDNTbe loseAll the External Alarms which are not used must be looped properly & if there isno space of looping then just twist them together separately (Should beSoldered) & tape them nicely (Dont Hang them) THANK YOU