Upload
others
View
2
Download
0
Embed Size (px)
Citation preview
E i
Disconnect Switches
Type VB Panelboard Units, AccessoriesSELECTION
Extension KitsTo extend Vacu-Break unit's depth,order the extension kit which meetsthe specifications of the unit to beextended. Specify by catalog numberfrom the table below.
Unit Type
V2A
V2B
V7A
V7B
V7E
V7F
Unit Height(inches)
2SS
5
2/2
5
7»
10
Normal Unit Depth(inches)
49/,s
49/,6
6%
6%
6%
6%
Extended Unit Depth(inches)
6%
6%10/2
10/2
10/2
10/2
Catalog Number
W43000
W43002
W48762
W48763
W48764
W48765
List Price $
31.00
31.00
89.00
89.00
114.00
136.00
Fuse Adapter Kits (see note below)To order the kit which meets the specifications of the unit tobe changed, specify by catalog number from the tables below.
240 Volt Fuse Adapter Kits 600 Volt Fuse Adapter Kits
SwitchAmperage
30®
60
60 (60/100)
100
200
400
600
Class R Kits
CatalogNumber
Factory Inst.
Factory Inst.
W56628
W55365
W55366
W55367
W55368
ListPrice $
—
—
67.00
45.00
45.00
67.00
67.00
Class J Kits
CatalogNumber
W49831
W49829
W49829
W49827
W49819
W49814
W49813
ListPrice $
121.00
121.00
121.00
98.00
98.00
245.00
340.00
Class T Kits
CatalogNumber
—
—
—
TFAK32
TFAK42
TFAK52
TFAK62
ListPrice $
—
—
—
47.00
64.00
64.00
75.00
SwitchAmperage
30
60
100
200
400
600
800
Class R Kits
CatalogNumber
W56623
W56629
W55365
W55366®
W55367
W55368
—
ListPrice $
63.00
63.00
45.00
45.00
67.00
67.00
—
Class J Kits
CatalogNumber
W49832
W49830
W49828
W49818®
W49816
W49815
—
ListPrice $
121.00
121.00
98.00
121.00
294.00
245.00
—
Class T Kits
CatalogNumber
—
—
TFAK35
TFAK45
TFAK55
TFAK65
TFAK75
ListPrice $
—
—
75.00
89.00
95.00
109.00
149.00
Vacu-Break Connecting Strap Kits For Panelboards and SwitchboardsAmpereRating
30-30
30-30
30-60
60-60
60-100
100-100
100
200
200-200
400
600
240V UnitHeight (inches)
2.5
5
5
5
7.5
7.5
7.5
7.5, 10
10
15
15
600V UnitHeight (inches)
—
7.5
7.5
7.5
7.5
7.5
7.5
7.5, 10
10
15
15
S4/F1, FPP (10" Deep)Strap Kit
F602
F657
F657
F657
F657
F657
F657
F671
F672
—
—
ListPrice $
39.50
39.50
39.50
39.50
39.50
39.50
39.50
60.00
366.00
—
—
S5/F2 (12.75" Deep)Strap Kit
F602D
F657D
F657D
F657D
F657D
F657D
F657D
F671D
F672D
—
F6150D
ListPrice $
179.00
216.00
216.00
216.00
216.00
216.00
216.00
335.00
366.00
—
158.00
SB1, SB2, SB3, FC-20, FC-1VB-5, VB-6, Strap Kit
—
VB657
VB657
VB657
VB657
VB657
VB657
VB671
—
VB6150
VB6150
ListPrice S
—
237.00
237.00
237.00
237.00
237.00
237.00
367.00
—
164.00
164.00
For inches / millimeters conversion, see Application Datasection.
Note: Class R and Class J Fuse Kits are single unit part num-bers. Order (2) kits for dual units. Class T Fuse Kits aresingle pole part numbers. Order (3) kits for a 3-pole unit.
©For 200 A single units only. Dual units are suitable for Class Jonly, when used above 240V.
©5" unit height switches only.
Siemens Electrical Products SPEEDFAX 2000 Discount Schedule I
Disconnect Switches
Type VB Panelboard UnitsVacu-Break® Fusible Units For SB1, SB2 Switchboards and F1, F2 Panelboards
SELECTION
AmpereRating
UnitHeight(inches)
UnitDepth(inches)
Horsepower Rating480 Volt ACStandard Maximum
600 Volt ACStandard Maximum
Number and RangeLugs Per Pole
UnitWeight(pounds)
CatalogNumber
ListPrice $
2-Pole, Branch Circuits, 17" Wide Units® 600 Volt30-30
30-60
60-60
100
100-100
200
400
600
Tk
Vh
Vh
Tk
Vh
10
15
15
6%
6%
6%
6%
6%
6%
101/!
ioyz
3
3-5
5
10
10
25
—
—
7/2
7/2-20
20
20
30
50
—
—
3
3-5
10
15
15
30
—
—
10
20-25
25
40
40
50
—
—
(1MM4to#8
(1)-#14to#4
(1)-#14to#4
(1 HMO to #1/0
(1 HMO to #1/0
(1)-#6to250kcmil
(1)-#1/0to500kcmil
(2)-#4/Oto500kcmil
14
14
14
14
20
21
63
63
V7E2611__®
V7E2612__®
V7E2622__®
V7E2603__®
V7E2633__®
V7F2604__®
V7H2605__®
V7H2606__®
664.00
664.00
664.00
471.00
936.00
1036.00
2133.00
2355.00
3-Pole, Branch Circuits, 17" Wide Units 600 Volt30-30
30-30
30-60
60-60
60-60
60-100
100-100
100-100
100
200-200
200
200
400
400
600
7/2
Vh
Vk
Vh
Vh
Vk
Vh
Vk
Vk
10
10
10
15
15
15
6%
6%
6%
6%
m6%
e%6%
6%
6%
6%
6%
Wk
10'/2
WA
5
5
5-15
15
15
15-25
25
25
25
50
50
50
100
100
150
15
15
15-30
30
30
30-60
60
60
60
125
125
125
250
250
400
Vk
Vk
7'/2-15
15
15
15-30
30
30
30
60
60
60
125
125
200
20
20
20-50
50
50
50-75
75
75
75
150
150
150
350
350
500
(1)-#14to#8
(1)-#14to#8
(1)-#14to#4
(1)-#14to#4
(1)-#14to#4
(1)-#10to#1/0
(1)-#10to#1/0
(1)-#10to#1/0
(1)-#10to#1/0
(1)-#6to250kcmil
(1)-#6to250kcmil
(1)-#6to250kcmil
(1)-#1/0to500kcmilor(2)-#1/0 to 300 kcmil
(1)-250to750kcmilor(2)-#1/0 to 300 kcmil
(2)-#4/0 to 500 kcmil
14
14
14
14
14
18
20
20
14
40
21
21
63
63
63
V7E3611
V7E3611R®
V7E3612
V7E3622
V7E3622R®
V7E3623
V7E3633
V7E3633R®
V7E3603
V7F3644®
V7F3604
WF3604R®
V7H3605
V7H3605750
V7H3606
853.00
979.00
853.00
853.00
979.00
1197.00
1197.00
1287.00
583.00
1996.00
1086.00
1131.00
2521.00
2521.00
2604.00
3-Pole, Main Switch, 17" Wide Units (Vertical Mount, Top Feed, Front Connected)400
600
18.75
18.75
10%
10%
100
150
250
400
125
200
350
500
®
®—
—
VMS365T
VMS366T
2521.00
2604.00
3-Pole, Main Switch, 17" Wide Units (Vertical Mount, Bottom Feed, Front Connected)400
600
18.75
18.75
17"/16
17"/16
100
150
250
400
125
200
350
500
®
®—
—
VMS365B
VMS366B
2521.00
2604.00
3-Pole, Main Switch, 17" Wide Units, Back Connected 600 Volt100
200
400
600
Vh
10
15
15
6%
6%
10>4
10>2
25
50
100
150
50
125
250
400
30
60
125
200
50
150
350
500
®
®
aa
14
21
63
63
V7E3603MS
V7F3604MS
V7H3605MS
V7H3606MS
583.00
1086.00
2521.00
2604.00
3-Pole, Switchboard Units, 21" Wide Units, Front Connected® 600 Volt800
1200
25
25
12%
12%
200
—
500
—
250
—
500®
160
160
VF357TL or BL®
VF358TL or BL®
5833.00
5983.00
3-Pole, Switchboard Units, 21" Wide, Back Connected800
1200
25
25
12%
12%
200
—
500
—
250
—
500®
160
160
VB357TL or BL®
VB358TL or BL®
5362.00
5623.00
®0rder 2-pole branch circuit units by adding appropriateconnection designation LM, LR or MR (indicating Left,Middle and Right, facing the panel).
©Unit configured to accept class J fuses only.©Load-side furnished with spade type bolted terminal pads.®Suffix "T" or "TL" indicates Top Feed.
Suffix "B" or "BL" indicates Bottom Feed.
is Back connected units are also available. Substitute the letter"B" (back connected) for the letter "F" (front connected)in the prefix of the catalog number. All other featuresare identical.
©Switches set up for R-fuse applications only.Built to order. Allow 4-6 weeks for delivery.
Discount Schedule I Siemens Electrical Products SPEEDFAX 2000