    THEME: Electronic

    TheodolitePENTAX ETH-302

    ( series 300 )

    Surveyors :

    Huerta Julian

    Huamn Wilber

    Navarro Gustavo

  • 7/31/2019 Exposure of Technical English( Sencico)

    3/34

    Haga clic para modificar el estilo de subttulo del patrn

    6/12/12

    Theodolite electronic PENTAX

    ETH-302

  • 7/31/2019 Exposure of Technical English( Sencico)

    4/34

    6/12/12

    Storing and environmentalconditions.

  • 7/31/2019 Exposure of Technical English( Sencico)

    5/34

    6/12/12

    Battery.

    Do not use batteries which have differentremaining capacities.

    The four batteries should be on the sametype.

  • 7/31/2019 Exposure of Technical English( Sencico)

    6/34

    6/12/12

    Transportation.

    When transporting, handle the same asfragile and pack the shipping case with

    cushioning materials.

  • 7/31/2019 Exposure of Technical English( Sencico)

    7/34

    6/12/12

    Inspeccion, adjustment andrepair, overhaul.

    When not use for extended periods ofhaving been subject to impact or vibration,

    be sure to check the instrumentadjustments before using.

  • 7/31/2019 Exposure of Technical English( Sencico)

    8/34

    6/12/12 Other.

    When cleaning the case or the instrument,do not use any organic solvent. The

    surface of plastic parts may dissolve anddeformation and discoloration can accur.Wipe off the dirt with a wet cloth of dilutehousehold detergent.

  • 7/31/2019 Exposure of Technical English( Sencico)

    9/34

    6/12/12 Names of parts.

  • 7/31/2019 Exposure of Technical English( Sencico)

    10/34

    6/12/12 Names of parts.

  • 7/31/2019 Exposure of Technical English( Sencico)

    11/34

    Haga clic para modificar el estilo de subttulo del patrn

    6/12/12

    2.1 Display

    2. Key Operations and Display

    Vertical

    angle

    V=Zenith0, V%=Slope(VH=Horizontal 0,Vc=Compass)

    Horizontal

    angleBattery

    indicator:

  • 7/31/2019 Exposure of Technical English( Sencico)

    12/34

    Haga clic para modificar el estilo de subttulo del patrn

    6/12/12

    2.2 Keyboard

    [V/%] key

    (Switches thedisplay of verticalangle)

    [R/L] keyset the

    horizontal angle

    right and leftrotationalternately )

  • 7/31/2019 Exposure of Technical English( Sencico)

    13/34

    6/12/12

    [HOLD] key(Pressing twice holds

    the horizontal angleshown on the display)

    [0SET] key(Pressing twice resetsthe horizontal angle to

    0,00,00)[ ] Illumination key(Illuminate LCD paneland the telescopereticle)

    [ON/OFF] key (Turnsthe power on and offalternately)

  • 7/31/2019 Exposure of Technical English( Sencico)

    14/34

    6/12/12

    2.3.1

    Power

    [ON/OFF]

    key

    2.3 Function of each key

    1

    Pressing the

    ON/OFF key turns

    on the powersupply and themessage

    0 SET is

    displayed. After

    the 0 SET ofvertical angle is

    performed,

    the Horizontal

    and Vertical angle

    are displayed andthe instrument

  • 7/31/2019 Exposure of Technical English( Sencico)

    15/34

    6/12/12

    Error Appears OVER RANGE when thetelescope exceeds 45(100%) in viewing

    mode V%.

  • 7/31/2019 Exposure of Technical English( Sencico)

    16/34

    6/12/12

    2.4.1

    Remainingbattery

    indicator

    2.4 Other Functions

    The status of theremaining batterycapacity isdisplayed with

    symbolizing thebattery capacity.

    Battery full -

    operating possible

    Operation possibleOperation still

    possible Get the battery

    ready for a stand

    by

  • 7/31/2019 Exposure of Technical English( Sencico)

    17/34

    6/12/12

    Automatic Power-off function

    If there is no key operation for about 30minutes, the power supply isturned off automatically.

    This function can be set to NIL by specialkey operation. (Refer to 3.5Setting of automatic power off function

  • 7/31/2019 Exposure of Technical English( Sencico)

    18/34

    6/12/12

    1) Adjust the tripod legs so that a height suitable for surveying isobtained when the instrument is set on the tripod

    2) A Set the tripod and fix the metal shoe firmly into the ground

    so thatthe tripod head is as level as possible and centered above the

    stationpoint. If the tripod head is disturbed by the action of fixing the

    metalshoe into the ground, correct the level by extending or

    retracting eachleg of the tripod.

    3) Set the instrument on the tripod head; insert the tripod centerscrew

    into the instrument bottom plate and tighten firmly.

    PREPARATION FOR SURVEYINGSetting up the instrument

  • 7/31/2019 Exposure of Technical English( Sencico)

    19/34

    6/12/12

    Leveling with the Circular

    levelAfter [ Setting up the instrument] is

    completed, instrument must be leveledusing the circular vial.1) By rotating any two leveling screws,position the bubble in the center of the vial(See A.) (To adjust the screws at the sametime, turn them in opposite directions.)

    2) Adjust the remaining leveling screw, andposition the bubble in the center of the circle(See B)

  • 7/31/2019 Exposure of Technical English( Sencico)

    20/34

    6/12/12

    Leveling with the Plate level

    1) Place the plate vial in parallel with a linejoining any two of the leveling screws. Byrotating two leveling screws in the oppositedirection of each other, position the bubble inthe center of the vial (See A)

    2) Rotate the plate vial through 90, positionthe bubble in the center of the vial byoperating the remaining one leveling screw(See

    3) Confirm if the bubble stays in the center byrotating the instrument 180.If the bubble moves, repeat procedure 1

    and 2.

  • 7/31/2019 Exposure of Technical English( Sencico)

    21/34

    6/12/12

    Loosen the tripod center screw. Look through theoptical plummet eyepiece, and move the instrumentbottom plate until the reticule center coincides with thestation point. (Take care not to rotate the instrument)

    Centering with the optical plummet

  • 7/31/2019 Exposure of Technical English( Sencico)

    22/34

    6/12/12

    Eyepiece adjustment

    focus the telescope eyepiece on thetelescope reticule Remove the telescope lenscap. Point the telescope at a bright object.Rotate the eyepiece completelycounterclockwise. Look through theeyepiece, and rotate the eyepiece clockwiseuntil the reticule appears at its maximum

    sharpness.

  • 7/31/2019 Exposure of Technical English( Sencico)

    23/34

    6/12/12

    sight the object.1) Loosen the telescope clamp screw andhorizontal clamp screw.2) Point the telescope at the object using thecollimator sight.

    3) Tighten the telescope clamp screw andhorizontal clamp screw.4) Focus on the object by rotating the focusingring, while looking

    through the telescope.5)Accurately align the reticule with the object,using each

    Tangent screw.

    Object sighting

  • 7/31/2019 Exposure of Technical English( Sencico)

    24/34

    6/12/12

    Measurement

    5.1 Horizontal angle measurement (right)Level the instrument, and after power on set the vertical angle 0 point.

    Sight the first object using the horizontal clamp and tangent screw as

    well as the telescope clamp and tangent screw.

    Press [0SET] twice to set the horizontal angle to 0,00,00

    Sight the second object using the horizontal clamp and tangent

    screw as well as the telescope clamp and tangent screw.

    Read the displayed value (B).

  • 7/31/2019 Exposure of Technical English( Sencico)

    25/34

    6/12/12

    Horizontal angle measurement(counterclockwise)

    Press the [R/L] key to switch the horizontalangle display to

    counterclockwise reading (HL).

  • 7/31/2019 Exposure of Technical English( Sencico)

    26/34

    6/12/12

    Vertical angle measurement

    Level the instrument, turn thepower on and set the verticalangle 0 point.

    Sight the object A using thehorizontal clamp and tangent

    screws as wellas the telescope clamp and

    tangent screws.

    Factory setting is Zenith 0

  • 7/31/2019 Exposure of Technical English( Sencico)

    27/34

    6/12/12

    Azimuth calculation

    First we locate the north with the compass andput at zero angle and then We targeted

    the point you want to calculate the azimuth.

  • 7/31/2019 Exposure of Technical English( Sencico)

    28/34

    6/12/12

    Inspection and Adjustment

  • 7/31/2019 Exposure of Technical English( Sencico)

    29/34

    6/12/12

    Instructions on inspection and adjustment

    Inspection and adjustment should be doneafter setting the instrument on a tripod or onan adjustment stand. Inspection should be done sequentially from[6.2 Plate vial] to [6.5 Perpendicularity of line

    of sight to horizontal axis] Adjustments should be finished withadjustment screws having been tightened andwith firm torque. Do not finish by loosening anadjustment screw.

    Repeat inspection after adjustment andconfirm if the adjustment is performedcorrectly. It is recommended that a trained professional

    perform adjustments, if possible.

  • 7/31/2019 Exposure of Technical English( Sencico)

    30/34

    6/12/12

    Perpendicularity of plate vial to vertical axis

    AdjustmentCenter the plate vial bubble.Rotate the instrument 180, move the bubble half wayback to the center by operating a leveling screw whichis located parallel with the plate vial.Rotate the vial adjusting screw with the adjusting pin

    and position the bubble in the center.Repeat procedure again to confirm.

  • 7/31/2019 Exposure of Technical English( Sencico)

    31/34

    6/12/12

    Perpendicularity of circular vial to vertical axis

    Inspection1. Confirm if the bubble of the circular vial is in the

    center after the inspection and adjustment of [6.2Plate vial].

    2. No adjustment is necessary if the bubble of thecircular vial is in the center but if not, the followingadjustment is required.

    Adjustment1. Move bubble to the center by rotating the bubble

    adjusting screws, using the adjusting pin.2. Inspect again.

  • 7/31/2019 Exposure of Technical English( Sencico)

    32/34

    6/12/12

    Difference of the vertical angle

    InspectionSet the vertical angle in Zenith 0 mode

    Sight an object (Point P) with the telescope and read

    the vertical angle (V correct).

    Reverse the telescope and rotate the alidade.

    Sight point P again in the reverse position and read the

    vertical angle (V reverse).

    At this time, when (V correct + V reverse - 360)/2 isless than 15, it is within tolerance. If it shows a larger

    value, it needs adjustment - Consult your dealer.

  • 7/31/2019 Exposure of Technical English( Sencico)

    33/34

    6/12/12

    Optical plummet

    AdjustmentRemove the cover of the optical plummet.Mark the point set on the line of sight at each stepof 90 on the white paper and call them A,B, C andD.Join the opposed points (A, C and B, D) with a

    straight line, and set intersecting point 0.Turn four optical plummet adjusting screws with theadjusting pin so that the center mark coincideswith the intersection point 0.Repeat procedure again to confirm.Optical plummet adjusting screw.