2
Experience Gamma Finder’s Next Generation Performance Detect relevant isotopes while gaining complete control with the only self-contained device Order number Description Contents GMFDR003 Gamma Finder ® III Wireless Gamma Detector 1 Probe, 1 Charging Case 1031 Protective Sterile Sleeves for Gamma Finder ® III 50 Sleeves/case Gamma Finder ® III Wireless Gamma Detector GAMMA FINDER ® III CHARGER CHARGING/STORAGE CASE POWER SUPPLY CHARGING CASE Begin charging probe by simply setting it into the charging storage case BD and the BD Logo are trademarks of Becton, Dickinson and Company or its affiliates. Gamma Finder III is the trademark of World of Medicine, a Novanta Company. © 2020 BD. All rights reserved. BD-13808v3 1.800.323.9088 www.crbard.com/biopsy GammaFinder ® III Wireless Gamma Detection Device INDICATIONS FOR USE: The Gamma Finder ® III is intended for the detection of gamma radiation in the energy range from 20 keV to 512 keV. The Gamma Finder ® III is indicated for the extra- and intra-operative detection of radioactively labelled substances mainly in the fields breast cancer and malignant melanoma. CONTRAINDICATIONS: Dosimetric applications, detection of radiation other than gamma, and detection of radiopharmaceuticals with radiation energies outside the above listed energy range are contraindicated. SAFETY NOTES: 1. Only trained technicians and qualified personnel may use the device. 2. U.S. law stipulates that this device be used only by a physician or under supervision of a physician. Please consult product labels and inserts for complete indications, contraindications, hazards, warnings, precautions and directions for use.

Experience Gamma Finder’s Next Generation Performance - Advancing the World … · 2021. 3. 7. · Experience Gamma Finder’s Next Generation Performance Detect relevant isotopes

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Experience Gamma Finder’s Next Generation Performance - Advancing the World … · 2021. 3. 7. · Experience Gamma Finder’s Next Generation Performance Detect relevant isotopes

Experience Gamma Finder’sNext Generation Performance Detect relevant isotopes while gaining complete control with the only self-contained device

Order number Description Contents

GMFDR003 Gamma Finder® III Wireless Gamma Detector 1 Probe, 1 Charging Case

1031 Protective Sterile Sleeves for Gamma Finder® III 50 Sleeves/case

Gamma Finder® III Wireless Gamma Detector

GAMMA FINDER® III CHARGER

CHARGING/STORAGE CASE

POWER SUPPLY

CHARGING CASE• Begin charging probe by simply setting it into the charging storage case

BD and the BD Logo are trademarks of Becton, Dickinson and Company or its affiliates. Gamma Finder III is the trademark of World of Medicine, a Novanta Company. © 2020 BD. All rights reserved. BD-13808v3

1.800.323.9088

www.crbard.com/biopsy

GammaFinder® III Wireless Gamma Detection DeviceINDICATIONS FOR USE: The Gamma Finder® III is intended for the detection of gamma radiation in the energy range from 20 keV to 512 keV. The Gamma Finder® III is indicated for the extra- and intra-operative detection of radioactively labelled substances mainly in the fields breast cancer and malignant melanoma. CONTRAINDICATIONS: Dosimetric applications, detection of radiation other than gamma, and detection of radiopharmaceuticals with radiation energies outside the above listed energy range are contraindicated. SAFETY NOTES: 1. Only trained technicians and qualified personnel may use the device. 2. U.S. law stipulates that this device be used only by a physician or under supervision of a physician. Please consult product labels and inserts for complete indications, contraindications, hazards, warnings, precautions and directions for use.

Page 2: Experience Gamma Finder’s Next Generation Performance - Advancing the World … · 2021. 3. 7. · Experience Gamma Finder’s Next Generation Performance Detect relevant isotopes

Streamlined and self-contained design to put complete control in your handsSelf-contained freedom• Eliminate tethered or remote consoles with the only self-contained device

Focus and control• With the controls in the palm of your hand, you are free to maintain focus within the sterile field

All-in-one convenience• A single probe detects entire 20-512keV detection range and allows for simultaneous lymphatic mapping and tumor localization

Streamlined and intuitive• A user-friendly interface and large display enable you to easily read counts or change settings

EXPANDED ENERGY DETECTION RANGE• Entire 20-512 KeV detection range in single probe, eliminating need for multiple probes• Includes simultaneous detection of I-125 and TC-99m• Background mode allows for detection of parathyroid glands

USER-FRIENDLY INTERFACE• Large, bright display is backlit for your easy reference• Display provides all relevant procedure data in your hands• Intuitive controls—Menu selections are just one click away from

the OR screen• Option to display 10 second count as cumulative sum or an average. Result of 10 second count remains displayed on the lower portion of the screen

SELF-CONTAINED CONTROL & CONVENIENCE• Read counts and change settings easily within the sterile field

Battery level indicator

Maximum count in CPS

Current isotope

Current count rate in counts per second (CPS)

IMPROVED ACOUSTIC OUTPUT*• Three volume levels• Audible feedback adjusts to level of radioactivity

RECHARGEABLE BATTERY• Charging case recharges gamma finder probe

COMPLETELY SELF-CONTAINED• Lighter, more ergonomic design*• Only completely self-contained detector

*Compared to Gamma Finder II.