16
EXLUX ECOLUX C-LUX 6000 • 6008 • 6400 • 6408 • 6600 • 6608 • 6500 INNOVATIVE EXPLOSION PROTECTION by R. STAHL 1-800-782-4357 Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications Features: Electronic Ballasts For Fluorescent Bipin Lamps One or two-lamp versions: 8W 17W 32W 40W Enclosure Material: FRP Cover Material: Polycarbonate LIGHTING B

EXLUX ECOLUX C-LUX · exlux • ecolux • c-lux 6000 • 6008 • 6400 • 6408 • 6600 • 6608 • 6500 innovative explosion protection by r. stahl 1-800-782-4357

  • Upload
    others

  • View
    16

  • Download
    0

Embed Size (px)

Citation preview

Page 1: EXLUX ECOLUX C-LUX · exlux • ecolux • c-lux 6000 • 6008 • 6400 • 6408 • 6600 • 6608 • 6500 innovative explosion protection by r. stahl 1-800-782-4357

EXLUX • ECOLUX • C-LUX 6000 • 6008 • 6400 • 6408 • 6600 • 6608 • 6500

INNOVATIVE EXPLOSION PROTECTION by R. STAHL 1-800-782-4357

Explosion ProtectedFluorescent Lighting Fixtures for Hazardous andCorrosive Applications Features:• Electronic Ballasts• For Fluorescent

Bipin Lamps• One or two-lamp versions:

8W17W32W40W

• Enclosure Material: FRP• Cover Material:

Polycarbonate

L I G H T I N G

B

Page 2: EXLUX ECOLUX C-LUX · exlux • ecolux • c-lux 6000 • 6008 • 6400 • 6408 • 6600 • 6608 • 6500 innovative explosion protection by r. stahl 1-800-782-4357

EXLUX 6000 Series

EXPLOSION PROTECTED FLUORESCENT LIGHTING FIXTURES FOR HAZARDOUS

AND CORROSIVE APPLICATIONS

INNOVATIVE EXPLOSION PROTECTION by R. STAHL 1-800-782-4357

17 Watt, 2'

32 Watt, 4'

6000/531-8091-8130-120-60 1-lamp fixture 120/125V AC/DC 0-60Hz, dead-end wiring, Entries: *6000/531-8591-8150-120-60 1-lamp fixture 120/125V AC/DC 0-60Hz, 5 wire feed-thru, Entries: *

6000/532-8091-8130-120-60 2-lamp fixture 120/125V AC/DC 0-60Hz, dead-end wiring, Entries: *6000/532-8591-8150-120-60 2-lamp fixture 120/125V AC/DC 0-60Hz, 5 wire feed-thru, Entries: *

6000/551-8091-8130-120-60 1-lamp fixture 120/125V AC/DC 0-60Hz, dead-end wiring, Entries: *6000/551-8591-8150-120-60 1-lamp fixture 120/125V AC/DC 0-60Hz, 5 wire feed-thru, Entries: *

6000/552-8091-8130-120-60 2-lamp fixture 120/125V AC/DC 0-60Hz, dead-end wiring, Entries: *6000/552-8591-8150-120-60 2-lamp fixture 120/125V AC/DC 0-60Hz, 5 wire feed-thru, Entries: *

6000/571-8091-8130-120-60 1-lamp fixture 120/125V AC/DC 0-60Hz, dead-end wiring, Entries: *6000/571-8591-8150-120-60 1-lamp fixture 120/125V AC/DC 0-60Hz,5 wire feed-thru, Entries: *

6000/572-8091-8130-120-60 2-lamp fixture 120/125V AC/DC 0-60Hz,dead-end wiring, Entries: *6000/572-8591-8150-120-60 2-lamp fixture 120/125V AC/DC 0-60Hz, 5 wire feed-thru, Entries: *

40 Watt, 5'

Catalog Number Description

Fluorescent Lighting Fixtures for Div. 2, Zone 1 and Zone 2 ApplicationsFixtures for Use with Standard T8 Med. Bipin Lamps

* Possible entries either end: 1 x 1/2", or 2 x 1/2", or 1 x 3/4" NPT. Please specify.For parts and accessories see pages B6-B8.

Ordering Information

CLASSIFICATIONSNEC- Class I, Zone 1 & 2, AEx de IIC T4

Class I, Division 2, Groups A,B,C,D, T4Class II, Divisions 1 & 2, Groups E,F,GClass III NEMA 3, 4, 4X & IP66File No. J.I.3D2A9.AE

CEC- Class I, Zone 1 & 2, Ex de IIC T4Class I, Division 2, Groups A,B,C,D, T4Class II, Divisions 1 & 2, Groups E,F,GClass III

CSA ENCLOSURES TYPE 3,4 & 4X; IP66Certified File No. LR99480

Ambient Temperature Range:+55°C (+131˚F) Max.–20°C (–4˚F) Min.

Supply Voltage 120 ±10% AC/DC 0-60Hz

FEATURESThe EXLUX 6000 Series of LightingFixtures are designed for hostile and hazardous locations where reliability and rugged performance are critical. The housing is constructed of heavy-duty fiberglass reinforced polyester (FRP) with a single piece, low glare polycarbonate lens. The EXLUX 6000 Series is supplied with electronic ballasts as standard and is available in 17, 32 and 40-watt one or two-lamp versions. The appropriatelamps are standard T8 medium bipinlamps. The fixtures are available in eitherdead-end or feed-through wiring. The ballasts are encapsulated in a self-contained flameproof enclosure withincreased safety terminals for the highestdegree of safety.The electronic ballast meets ANSI C82.11standards regarding harmonic distortion.

INSTALLATIONThe fixture includes threaded NPT open-ings with grounded backplates and NPTclose-up plugs. For MC-HL cable installa-tion use TMC cable glands. For conduit installation use conduit hubs8166/11-0•-N.

L I G H T I N G

B1

Page 3: EXLUX ECOLUX C-LUX · exlux • ecolux • c-lux 6000 • 6008 • 6400 • 6408 • 6600 • 6608 • 6500 innovative explosion protection by r. stahl 1-800-782-4357

EXLUX 6008 Series

EXPLOSION PROTECTED FLUORESCENT EMERGENCY LIGHTING FIXTURES WITH AUTO-TESTING EMERGENCY BALLAST.

INNOVATIVE EXPLOSION PROTECTION by R. STAHL 1-800-782-4357

CLASSIFICATIONSNEC- Class I, Zone 1 & 2, AEx dem IIC T4

Class I, Division 2, Groups A,B,C,D, T4Class II, Divisions 1 & 2, Groups E,F,GClass III NEMA 3, 4, 4X & IP66File No. J.I.3D2A9.AE

CEC- Class I, Zone 1 & 2, Ex dem IIC T4Class I, Division 2, Groups A,B,C,D, T4Class II, Divisions 1 & 2, Groups E,F,GClass III CSA ENCLOSURES TYPE 3,4 & 4X; IP66Certified File No. LR99480

Supply Voltage 120V, 50-60HzAmbient Temperature Range:

AC & Battery Operation +50°C (+122˚F) Max.–20°C (–4˚F) Min.

Charging & Test Operation +50°C (+122˚F) Max.–5°C (+23˚F) Min.

FEATURESThe EXLUX 6008 Series carries out pre-programmed testing schedules, monitorsemergency ballast performance and batterycharging. In case of power failure the Auto-test-ing Emergency Ballast automatically switches toemergency mode, keeping one lamp illuminatedat reduced lumen output for a minimum of 90minutes. When AC power is restored, the fixturereturns to AC supply. It also can be set for 3hours emergency operation with reduced lightoutput. The EXLUX 6008 Series of EmergencyLighting Fixtures are designed for hostile andhazardous locations where reliability and ruggedperformance are critical. The housing is con-structed of fiberglass reinforced polyester (FRP)with a single piece, low glare polycarbonate lens.It is supplied with flameproof electronic ballastsas standard and is available in 1x 32 Watts and2x 32 Watts versions.INSTALLATIONThe fixture includes threaded NPT openings withgrounded backplates and NPT close-up plugs.For MC-HL cable installation use TMC cableglands. For conduit installation use conduit hubs8166/11-0•-N (see page B7). The fixture must bewired with a permanent charging phase whichneeds to be the same potential as the switchedphase. The terminal capacity is 2 stranded wires10 AWG per terminal.PERIODIC AUTO TESTINGThe fixture automatically performs a weekly functional test. The discharge test is factory set for manual testing. If automatic testing is preferred the jumper wire needs to be removedas explained in the IOM sheet.STATUS INDICATOR DISPLAYOne red LED and one green LED are incorporated into the fixture and can be seenfrom the outside through the lens. The functionsand test results are listed on this page.

Emergency Fluorescent Lighting Fixtures - With Battery Back-up Units forDiv. 2, Zone 1 & Zone 2 ApplicationsFixtures for use with Standard T8 Med. Bipin Lamps

32 Watt, 4'

6008/552-9097-8140-120-60 Auto Testing, 2-lamp fixture 120V 60Hz, dead-end wiring, Entries: *6008/552-9697-8160-120-60 Auto Testing, 2-lamp fixture 120V 60Hz, 6 wire feed-thru, Entries: *

Catalog NumberDescription

* Possible entries either end: 1 x 1/2", or 2 x 1/2", or 1 x 3/4" NPT. Please specify.For parts and accessories see pages B6-B8.

Ordering Information

Status Indicator Display

☺ Everything OK

¿Quarterly, Automatic Emergency Lighting Time Duration Test

 Weekly, Automatic Function Test

6 Emergency Lighting Time Operation Test.Battery holds ≤ 2/3 of the battery charge needed for the set Emergency light duration. Conclusion: Battery replacement needed

L Battery Empty – not in working condition

L Battery Defective (presumed cell polarity reversed)

Green LED permanently ON

Green LED 1 :1 blinking

Green LED 1:10 flashing

Red LED permanently ON

Red LED 1:1 blinking

Red LED 1 :10 flashing

LED Display Display Description

L I G H T I N G

B2

Page 4: EXLUX ECOLUX C-LUX · exlux • ecolux • c-lux 6000 • 6008 • 6400 • 6408 • 6600 • 6608 • 6500 innovative explosion protection by r. stahl 1-800-782-4357

EXLUX 6400 SeriesEXPLOSION PROTECTED FLUORESCENT LIGHTING FIXTURES

FOR HAZARDOUS AND CORROSIVE APPLICATIONS

INNOVATIVE EXPLOSION PROTECTION by R. STAHL 1-800-782-4357

CLASSIFICATIONSNEC- Class I, Zone 2, Group IIC T4

Class I, Division 2, Groups A,B,C,D, T4Class II, Divisions 1 & 2, Groups E,F,G, T5Class III NEMA 3, 4, 4X & IP66File No. J.I.3009378

CEC- Class I, Zone 2, Group IIC T4Class I, Division 2, Groups A,B,C,D, T4Class II, Divisions 1 & 2, Groups E,F,G, T5Class III

CSA ENCLOSURES TYPE 3,4 & 4X; IP66Certified File No. LR99480

Ambient Temperature:For Class I areas:

+55˚C (+131˚F) Max.; -18˚C (0˚F) Min.

For Class II & III areas:+40˚C (+104˚F) Max.; -18˚C (0˚F) Min.

Supply Voltages(see ordering information)

FEATURESThe EXLUX 6400 Series of Lighting Fixturesare designed for hostile and hazardous locations where reliability and rugged performance are critical. The housing is constructed of heavy-duty fiberglass rein-forced polyester (FRP) with a single piece,low glare polycarbonate lens. The EXLUX 6400 Series is supplied withelectronic instant-start ballasts as standardand is available in 17, 32 and 40-watt one ortwo-lamp versions. The two-lamp versionsare dual channel, which keeps the fixture functional should one lamp fail. The powerfactor is ≥ .99. The electronic ballast meetsANSI C82.11 standards regarding harmonic distortion. INSTALLATIONThe fixture includes threaded NPT openingswith grounded backplates and NPT close-upplugs. For MC Cable installation use TMCcable glands. For conduit installation use conduit hub8166/11-0•-N.The appropriate lamps are standard T8 medium bipin lamps.

17 Watt, 2'

6400/531-8090-9000-120-277-50/60 1-lamp fixture 120-277V 50/60Hz, Entries: *6400/531-8090-9000-347-50/60 1-lamp fixture 347V 50/60Hz, Entries: *

6400/532-9090-9000-120-277-50/60 2-lamp fixture 120-277V 50/60Hz, Entries: *6400/532-9090-9000-347-50/60 2-lamp fixture 347V 50/60Hz, Entries: *

32 Watt, 4'

6400/551-8090-9000-120-277-50/60 1-lamp fixture 120-277V 50/60Hz, Entries: *6400/551-8090-9000-347-50/60 1-lamp fixture 347V 50/60Hz, Entries: *

6400/552-9090-9000-120-277-50/60 2-lamp fixture 120-277V 50/60Hz, Entries: *6400/552-9090-9000-347-50/60 2-lamp fixture 347V 50/60Hz, Entries: *

40 Watt, 5'

6400/571-8090-9000-120-277-50/60 1-lamp fixture 120-277V 50/60Hz, Entries: *

6400/572-9090-9000-120-277-50/60 2-lamp fixture 120-277V 50/60Hz, Entries: *

For optional cover interlock switch change these 0’s to 1’s.

* Possible entries either end: 1 x 1/2", or 2 x 1/2", or 1 x 3/4" NPT. Please specify.

For parts and accessories see pages B6-B8.

Catalog NumberDescription

Fluorescent Lighting Fixtures for Div. 2 and Zone 2 ApplicationsFixtures for Use with Standard T8 Med. Bipin Lamps

Ordering Information

L I G H T I N G

B3

Page 5: EXLUX ECOLUX C-LUX · exlux • ecolux • c-lux 6000 • 6008 • 6400 • 6408 • 6600 • 6608 • 6500 innovative explosion protection by r. stahl 1-800-782-4357

B4

EXLUX 6408 SeriesEXPLOSION PROTECTED FLUORESCENT EMERGENCY

LIGHTING FIXTURES FOR HAZARDOUS AND CORROSIVE APPLICATIONS

INNOVATIVE EXPLOSION PROTECTION by R. STAHL 1-800-782-4357

32 Watt, 4'

6408/552-9098-9000-120-277-50/60 2-lamp fixture 120-277V 50/60Hz, Entries: *

Catalog NumberDescription

Emergency Fluorescent Lighting Fixtures with Battery Back-up Unitfor Div. 2 and Zone 2 ApplicationsFixtures for use with Standard T8 Med. Bipin Lamps

* Possible entries either end: 1 x 1/2", or 2 x 1/2", or 1 x 3/4" NPT. Please specify.

For parts and accessories see pages B6-B8.

Hub for conduit installationCable gland for cable installation

Ordering Information

CLASSIFICATIONSNEC- Class I, Zone 2, Group IIC T4CEC- Class I, Division 2, Groups A,B,C,D, T4

Class II, Divisions 1 & 2, Groups E,F,G, T5Class III NEMA 3, 4, 4X & IP66File No. J.I.3009378CSA ENCLOSURES TYPE 3,4 & 4X; IP66Certified File No. LR99480

Ambient Temperature Range:For class I areas:

+50°C (+122°F) Max.-18°C (+0°F) Min.

For class II and III areas:+40°C (+104°F) Max.-18°C (+0°F) Min.

Supply Voltage Range from 120V, to 277V, 60 HzFEATURESThe EXLUX 6408 Series of EmergencyLighting fixture is equipped with one batteryback-up unit which in case of power failureautomatically switches over to battery supply keeping one lamp illuminated atreduced lumen output for a minimum of 90minutes. When AC power is restored, thefixture returns to AC supply. When the RedLED indicating light is illuminated the battery is being charged or monitored. It is visible from the outside through the lens. The EXLUX 6408 Series is also suppliedwith an AC electronic instant start ballastunit and is available in 2 x 17W or 2 x 32Wparallel lamps. This keeps the fixture func-tional should one lamp fail. The power factor is ≥ .99. The electronic ballast meetsANSI C82.11 standards regarding harmonicdistortion.The EXLUX 6408 Series are designed forhostile and hazardous locations where reli-ability and rugged performance are critical.The housing is constructed of heavy-duty fiberglass reinforced polyester (FRP) with asingle piece, low glare polycarbonate lens.

INSTALLATIONThe fixture includes threaded NPT open-ings with grounded backplates and NPTclose-up plugs. For MC Cable installationuse TMC cable glands. For conduit installa-tion use conduit hub 8166/11-0•-N.The fixture must be wired with a permanentcharging phase which needs to be thesame potential as the switched phase.The appropriate lamps are standard T8medium bipin lamps.

L I G H T I N G

Page 6: EXLUX ECOLUX C-LUX · exlux • ecolux • c-lux 6000 • 6008 • 6400 • 6408 • 6600 • 6608 • 6500 innovative explosion protection by r. stahl 1-800-782-4357

Dimensions

INNOVATIVE EXPLOSION PROTECTION by R. STAHL 1-800-782-4357B5

L1

L2

L3

For 3/4" NPTBoth Ends

143m

m

5.6"

5.6"

143m

m

8.7"221mm

M1478K

L1

L2

L3

For 3/4" NPTBoth Ends

M1476K

5.6"

143m

m

8.7"221mm

Dimensions

17W, 2' Fixture

inch

27.5"

15.7"

12.3"-18.3"

L1

L2 1)

L3 2)

1) fixed mounting distance2) variable mounting distance

mm

(700mm)

(400mm)

(312-465mm)

inch

51.5"

31.5"

26.3"-34"

mm

(1310mm)

(800mm)

(670-865mm)

inch

63.4"

31.5"

26.3"-34"

mm

(1610mm)

(800mm)

(670-865mm)

32W, 4' Fixture 40W, 5' Fixture

Dimensions

17W, 2' Fixture

inch mm

30.8" (782mm)

15.7" (400mm)

12.3"-18.3" (312-465mm)

inch mm

54.8" (1392mm)

31.5" (800mm)

26.4"-34" (670-865mm)

L1

L2 1)

L3 2)

1) fixed mounting distance2) variable mounting distance

32W, 4' Fixture

EXLUX 6000, 6400 & 6408 EXLUX 6008

L I G H T I N G

Page 7: EXLUX ECOLUX C-LUX · exlux • ecolux • c-lux 6000 • 6008 • 6400 • 6408 • 6600 • 6608 • 6500 innovative explosion protection by r. stahl 1-800-782-4357

Interlock Switch 8082/1-2 Interlock switch 1 NO 80 820 02 01 0for battery enclosure6008 fixture

Socket Wrench to operate the central 81 980 05 40 0 1/2'' (13mm) interlock mechanism

Entry Back-up Plate stainless steel back-up plate with set screw and groundingprovisions 1 x NPT 1/2'' 60 008 17 55 0entry threads: 2 x NPT 1/2'' 60 008 21 55 0

1 x NPT 3/4'' 60 008 18 55 0

Lamp Holder snap-in lamp holder for 6400 and 6408 fixtures 385 663 0

Lamp Holder snap-in lamp holder for 6000 and 6008 fixtures 60 418 04 65 0

Battery Pack for Battery capacity 7Ah 60 448 01 74 0fixture 6008

Eye Bolts M8 1 pair can directly be screwed 60 008 03 90 0into the fixture

Mounting Brackets with 1 pair of adjustable mounting brackets 60 008 07 75 0Suspension Lugs with suspension lugs

Ceiling Brackets 1 pair of adjustable ceiling 60 008 03 75 0mounting brackets

Pipe Clamps with 1 pair of stainless steel pipe clampsMounting Brackets with adjustable mounting brackets for

EMT 1 1/4" conduit 60 008 03 26 0EMT 1 1/2" conduit 60 008 01 26 0EMT 2" conduit 60 008 02 26 0

Parts and Accessories

INNOVATIVE EXPLOSION PROTECTION by R. STAHL 1-800-782-4357

L I G H T I N G

Use only the following original spare parts and accessories, any others would invalidate the certification and warranty.

Description Type Catalog Number

B6

Page 8: EXLUX ECOLUX C-LUX · exlux • ecolux • c-lux 6000 • 6008 • 6400 • 6408 • 6600 • 6608 • 6500 innovative explosion protection by r. stahl 1-800-782-4357

Parts and Accessories

INNOVATIVE EXPLOSION PROTECTION by R. STAHL 1-800-782-4357B7

Wall-Mounting Bracket 90˚ 1 pair of 90˚ stainless steel 60 008 02 44 0wall-mounting brackets

Wall-Mounting Bracket 50˚ 1 pair of 50˚ stainless steel 60 008 01 44 0wall-mounting brackets

Safety Clips 10 pcs. in one bag 60 008 02 94 0to avoid unintentional detachment of the lens from the fixture.

Cable Gland 1/2'' NPT for MC cable TMC 050

Sealing Ring 1/2'' NPT for above TMC 050 CMP 050 NPT ETS

Cable Gland 3/4'' NPT for MC cable TMC 075

Sealing Ring 3/4'' For above TMC 075 CMP 075 NPT ETS

Conduit Hub 1/2'' NPT Conduit hub 1/2'' NPT 8166/11-01-Nwith sealing ring

Conduit Hub 3/4'' NPT Conduit hub 3/4'' NPT 8166/11-02-Nwith sealing ring

Close-up Plug 1/2'' NPT Polymeric close-up plug 1/2'' NPT PD-E-4-0-29-00

Description Type Catalog Number

L I G H T I N G

Page 9: EXLUX ECOLUX C-LUX · exlux • ecolux • c-lux 6000 • 6008 • 6400 • 6408 • 6600 • 6608 • 6500 innovative explosion protection by r. stahl 1-800-782-4357

Parts and Accessories

INNOVATIVE EXPLOSION PROTECTION by R. STAHL 1-800-782-4357

L I G H T I N G

Description Type Catalog Number

Close-up Plug 3/4'' NPT Polymeric close-up plug 3/4'' NPT PD-E-4-0-30-00

Cast Wall and Corner Insert 1 1/2" EMT conduit into Mounting Bracket for the bracket. Use pipe clamp 461 717 0 Stanchion Mounting PN 60 008 01 26 0 to attach

fixture to conduit.

Lens for light fixture 2' 17W 60 000 33 05 04' 32W 60 000 34 05 05’ 40W 60 000 35 05 0

Interlock Switch Switch block 2 NC 80 800 06 60 08080/1–3-L 20e

Fuse to protect battery circuit 6.3A 85 600 19 01 0

Retrofit Kit for 6 Wire to retrofit dead-end fixture EXLUX 6008Feed-Through Wiring amperage rating 16 Amp max.or EXLUX 6008 LI , L1, L2, L3, N, PE

4' 32W 60 088 04 87 0

to retrofit dead-end fixture EXLUX 6000Retrofit Kit for 5 W ire amperage rating 16 Amp max.Feed-Through Wiring L1, L2, L3, N, PEfor EXLUX 6000 2' 17W 60 088 12 87 0

4' 32W 60 088 14 87 05' 40W 60 088 16 87 0

Electronic for use with fixtures 1x 17W 60 420 65 01 0Ballast Unit EXLUX 6000, 6008 2x 17W 60 420 53 01 0

& 6400/5 ..-8090-125 1x 32/40W 60 420 66 01 02x 32W 60 420 54 01 02x 40W 60 420 55 01 0

Auto Testing for use with Emergency Lighting Fixtures 60 430 18 74 0Emergency EXLUX 6008Ballast

Parabolic Reflector For 1-lamp fittings 17W 60 309 03 58 0For 1-lamp fittings 32W 60 309 04 58 0For 1-lamp fittings 40W 60 309 06 58 0For 2-lamp fittings 17W 60 309 01 58 0For 2-lamp fittings 32W 60 309 02 58 0For 2-lamp fittings 40W 60 309 05 58 0

B8

Page 10: EXLUX ECOLUX C-LUX · exlux • ecolux • c-lux 6000 • 6008 • 6400 • 6408 • 6600 • 6608 • 6500 innovative explosion protection by r. stahl 1-800-782-4357

L I G H T I N G ECOLUX 6600 SeriesEXPLOSION PROTECTED FLUORESCENT LIGHTING FIXTURES

FOR HAZARDOUS AND CORROSIVE APPLICATIONS

INNOVATIVE EXPLOSION PROTECTION by R. STAHL 1-800-782-4357

CLASSIFICATIONSNEC- Class I, Zone 2, Group IIC T5

Class I, Division 2, Groups A,B,C,DClass II, Divisions 1 & 2, Groups E,F,GClass III NEMA 3, 4, 4X & IP66File No. J.I.3012747

CEC- Class I, Zone 2, Group IIC T5Class I, Division 2, Groups A,B,C,DClass II, Divisions 1 & 2, Groups E,F,GClass III

CSA ENCLOSURES TYPE 3,4 & 4X; IP66Certified File No. 171050

Ambient Temperature Range:+40˚C (+104˚F) Max.; -18˚C (0˚F) Min.

Supply Voltages(see ordering information)

FEATURESThe ECOLUX 6600 Series of LightingFixtures are designed for hostile and hazardous locations where reliability andrugged performance are critical. The housing is constructed of heavy-duty fiber-glass reinforced polyester (FRP) with a single piece, low glare polycarbonate lens. The ECOLUX 6600 Series is supplied withelectronic instant-start ballasts as standardand is available in 17, 32 and 40-Watt, one or two-lamp versions. The two-lamp versions are dual channel, which keeps thefixture functional should one lamp fail. Thepower factor is ≥ .99. The electronic ballastmeets ANSI C82.11 standards regarding harmonic distortion. INSTALLATIONThe fixture includes threaded NPT openingswith grounded backplates and NPT close-upplugs. For MC Cable installation use TMCcable glands. For conduit installation use conduit hub8166/11-0•-N.The appropriate lamps are standard T8 medium Bi-pin lamps.

Fluorescent Lighting Fixtures for Div. 2 and Zone 2 ApplicationsFixtures for Use with Standard T8 Med. Bi-pin Lamps

For optional cover interlock switch change these 0’s to 1’s.

* Possible entries either end: 1 x 1/2", or 2 x 1/2", or 1 x 3/4" NPT. Please specify.

For parts and accessories see pages B11-B13.

L I G H T I N G

17 Watt, 2'

6600/531-8090-9000-120-277-50/60 1-lamp fixture 120-277V 50/60Hz, Entries: *6600/531-8090-9000-347-60 1-lamp fixture 347V 60Hz, Entries: *

6600/532-9090-9000-120-277-50/60 2-lamp fixture 120-277V 50/60Hz, Entries: *6600/532-9090-9000-347-60 2-lamp fixture 347V 60Hz, Entries: *

32 Watt, 4'

6600/551-8090-9000-120-277-50/60 1-lamp fixture 120-277V 50/60Hz, Entries: *6600/551-8090-9000-347-60 1-lamp fixture 347V 60Hz, Entries: *

6600/552-9090-9000-120-277-50/60 2-lamp fixture 120-277V 50/60Hz, Entries: *6600/552-9090-9000-347-60 2-lamp fixture 347V 60Hz, Entries: *

40 Watt, 5'

6600/571-8090-9000-120-277-50/60 1-lamp fixture 120-277V 50/60Hz, Entries: *

6600/572-9090-9000-120-277-50/60 2-lamp fixture 120-277V 50/60Hz, Entries: *

Catalog NumberDescription

Ordering Information

B9

Page 11: EXLUX ECOLUX C-LUX · exlux • ecolux • c-lux 6000 • 6008 • 6400 • 6408 • 6600 • 6608 • 6500 innovative explosion protection by r. stahl 1-800-782-4357

B10

ECOLUX 6608 SeriesEXPLOSION PROTECTED FLUORESCENT EMERGENCY

LIGHTING FIXTURES FOR HAZARDOUS AND CORROSIVE APPLICATIONS

INNOVATIVE EXPLOSION PROTECTION by R. STAHL 1-800-782-4357

Hub for conduit installationCable gland for cable installation

CLASSIFICATIONSNEC- Class I, Zone 2, Group IIC T5CEC- Class I, Division 2, Groups A,B,C,D

Class II, Divisions 1 & 2, Groups E,F,GClass III NEMA 3, 4, 4X & IP66File No. J.I.3012747

CEC- Class I, Zone 2, Group IIC T5Class I, Division 2, Groups A,B,C,DClass II, Divisions 1 & 2, Groups E,F,GClass III CSA ENCLOSURES TYPE 3,4 & 4X; IP66Certified File No. 171050

Ambient Temperature Range:+40°C (+104°F) Max.-18°C (0°F) Min.

Supply Voltage Range from 120V, to 277V, 60 HzFEATURESThe ECOLUX 6608 Series of EmergencyLighting fixture is equipped with one batteryback-up unit which in case of power failureautomatically switches over to battery supply keeping one lamp illuminated atreduced lumen output for a minimum of 90minutes. When AC power is restored, the fixture returns to AC supply. When the RedLED indicating light is illuminated the battery is being charged or monitored. It is visible from the outside through the lens. The ECOLUX 6608 Series is also suppliedwith an AC electronic instant start ballast unitand is available in 2 x 17W or 2 x 32W paral-lel lamps. This keeps the fixture functionalshould one lamp fail. The power factor is ≥ .99. The electronic ballast meets ANSI C82.11standards regarding harmonic distortion.The ECOLUX 6608 Series are designed forhostile and hazardous locations where relia-bility and rugged performance are critical.The housing is constructed of heavy-duty fiberglass reinforced polyester (FRP) with asingle piece, low glare polycarbonate lens.INSTALLATIONThe fixture includes threaded NPT openingswith grounded backplates and NPT close-up plugs. For MC Cable installation useTMC cable glands. For conduit installationuse conduit hub 8166/11-0•-N.The fixture must be wired with a permanentcharging phase which needs to be the samepotential as the switched phase.The appropriate lamps are standard T8medium Bi-pin lamps.

L I G H T I N G

17 Watt, 2'

32 Watt, 4'

6608/532-9098-9000-120-277-50/60 2-lamp fixture 120 to 277V 50/60Hz, Entries: *

6608/552-9098-9000-120-277-50/60 2-lamp fixture 120 to 277V 50/60Hz, Entries: *

Catalog NumberDescription

Emergency Fluorescent Lighting Fixtures with Battery Back-up Unitfor Div. 2 and Zone 2 ApplicationsFixtures for use with Standard T8 Med. Bi-pin Lamps

Ordering Information

* Possible entries either end: 1 x 1/2", or 2 x 1/2", or 1 x 3/4" NPT. Please specify.For parts and accessories see pages B11-B13.

B10

Page 12: EXLUX ECOLUX C-LUX · exlux • ecolux • c-lux 6000 • 6008 • 6400 • 6408 • 6600 • 6608 • 6500 innovative explosion protection by r. stahl 1-800-782-4357

Dimensions

INNOVATIVE EXPLOSION PROTECTION by R. STAHL 1-800-782-4357B11

L I G H T I N G

ECOLUX 6600 & 6608Dimensions Opening the Fixture

17 W 32 W 40 W

L1 700 mm 1310 mm 1610 mm27.5" 51.6" 63.4"

L2 400 mm 800 mm 800 mm15.75" 31.5" 31.5"

L3 340 - 460 mm 680 - 920 mm 795 - 1030 mm13.4" - 18.1" 26.8" - 36.2" 31.3" - 40.5"

Item Image Description Catalog Number

ConduitHub 1/2'' NPT Conduit hub 1/2'' NPT 8166/11-01-N

with sealing ring

Conduit Conduit hub 3/4'' NPT 8166/11-02-NHub 3/4'' NPT with sealing ring

Close-up plug 1/2'' NPT Polymeric close-up plug 1/2'' NPT PD-E-4-0-29-00

Close-up plug 3/4'' NPT Polymeric close-up plug 3/4'' NPT PD-E-4-0-30-00

For retro-fittingParabolic Reflector for 1-lamp fixtures: (Optional) 17W 60 309 03 58 0

32W 60 309 04 58 040W 60 309 06 58 0

for 2-lamp fixtures: 17W 60 309 01 58 032W 60 309 02 58 040W 60 309 05 58 0

Parts and Accessories

Use only the following original spare parts and accessories, any others would invalidate the certification and warranty.

Page 13: EXLUX ECOLUX C-LUX · exlux • ecolux • c-lux 6000 • 6008 • 6400 • 6408 • 6600 • 6608 • 6500 innovative explosion protection by r. stahl 1-800-782-4357

Parts and Accessories

INNOVATIVE EXPLOSION PROTECTION by R. STAHL 1-800-782-4357

L I G H T I N G

B12

Use only the following original spare parts and accessories, any others would invalidate the certification and warranty.

S0613P

Item Image Description Catalog NumberCast wall and corner Insert 1 1/2" EMT conduit into bracketmounting bracket for Use pipe clamps (PN 66 008 01 26 0) 461 717 0 stanchion mounting to attach fixture to conduit

Lens for light fixture 2' 17W 66 000 01 05 04' 32W 66 000 02 05 05' 40W 66 000 03 05 0

Color: White 10 Pieces 66 008 01 40 0

Snap Action Buckles Color: Black 6 Pieces 66 008 02 40 0

Color: Black 2 Pieces 66 008 03 40 0 with a borehole for switch actuation

Lamp Holder snap-in lamp holder 385 663 0

stainless steel back-up plate with set screw and grounding

Entry back-up plate provisions entry threads: 1 x NPT 1/2'' 60 008 17 55 02 x NPT 1/2'' 60 008 21 55 01 x NPT 3/4'' 60 008 18 55 0

1 pair of eye bolts M8 can be directly screwed 60 008 03 90 0 Eye bolts M8 into the inserts of the fixture for fixed

suspension points

CeilingMounting brackets 1 pair of fixed ceiling mounting brackets 60 008 03 75 0

for fixed mounting points

Page 14: EXLUX ECOLUX C-LUX · exlux • ecolux • c-lux 6000 • 6008 • 6400 • 6408 • 6600 • 6608 • 6500 innovative explosion protection by r. stahl 1-800-782-4357

Parts and Accessories

INNOVATIVE EXPLOSION PROTECTION by R. STAHL 1-800-782-4357B13

L I G H T I N G

Item Image Description Catalog Number

Mounting Brackets 1 pair of mounting brackets for adjustable mounting points 66 008 01 75 0

1 pair of stainless steel suspension lugs whichcan only be used together with mounting brackets 60 008 02 18 0P/N 66 008 01 75 0

Suspension Lugs

1 pair of stainless steel suspension lugs c/w 66 008 02 75 0adjustable mounting brackets for adjustablesuspension points

1 pair of stainless steel pipe clampsPipe Clamps c/w adjustable mounting brackets

for adjustable mounting points EMT 1 1/4" 66 008 05 26 0EMT 1 1/2" 66 008 01 26 0EMT 2" 66 008 02 26 0

1 pair of stainless steel wall mounting brackets Tiltable Wall which tilt at 15 ° increments complete withMounting bracket adjustable mounting brackets for adjustable 66 008 04 26 0

mounting points

Clamps for 1 pair of stainless steel brackets suitable for Wire Basket Systems fastening fixture to a wire basket system 66 008 03 26 0

Cable Gland 1/2'' NPT For standard MC Cable TMC 050

Sealing ring 1/2'' NPT For above TMC 050 CMP 050 NPT ETS

Cable Gland 3/4'' NPT For standard MC Cable TMC 075

Sealing ring 3/4'' For above TMC 075 CMP 075 NPT ETS

Page 15: EXLUX ECOLUX C-LUX · exlux • ecolux • c-lux 6000 • 6008 • 6400 • 6408 • 6600 • 6608 • 6500 innovative explosion protection by r. stahl 1-800-782-4357

C-LUX 6500 SeriesEXPLOSION PROTECTED COMPACT LIGHTING FIXTURES

FOR HAZARDOUS AND CORROSIVE INDOOR APPLICATIONS

INNOVATIVE EXPLOSION PROTECTION by R. STAHL 1-800-782-4357

L I G H T I N G

B14B15

CLASSIFICATIONSNEC- Class I, Zone 2, Group IIC T4

Class I, Division 2, Groups A,B,C,D, T4Class II & III, Divisions 1 & 2,

Groups E,F,G, T5Enclosure Type 3, 4, 4X & IP66File No. J.I.3012168

Ambient Temperature Range:+45˚C (+113˚F) Max.; +10˚C (+50˚F) Min.

Supply Voltage: 120V, 60 Hz

FEATURESThe C-LUX 6500 Series of LightingFixtures are small compact fixturesdesigned for indoor use, hostile and hazardous locations where reliability and rugged performance are critical. The housing is constructed of heavy-duty fiberglass reinforced polyester (FRP) with a single piece, low glare polycarbonate lens. The C-LUX 6500 Series is available either as a one, two or three-lamp version.

INSTALLATIONThe fixture is suitable for wall or ceilingmounting. It includes one threaded 3/4"NPT hub and two close-up plugs. To open the fixture use 1/2" socketwrench P/N 81 980 05 40 0.For parts and accessories see page B15.

Compact Fluorescent Lighting Fixtures for Div. 2 and Zone 2ApplicationsFixtures for use with T5 Miniature. Bi-pin 8 W att Lamp(s).

6500/1081-9090-9000-00-120-60 1-lamp fixture 120V 60Hz, 3/4" NPT Entries6500/1082-9090-9000-00-120-60 2-lamp fixture 120V 60Hz, 3/4" NPT Entries6500/1083-9090-9000-00-120-60 3-lamp fixture 120V 60Hz, 3/4" NPT Entries

For other entry openings, consult factory.For parts and accessories see page B15.

Catalog Number Description

Ordering Information

Dimensions

Page 16: EXLUX ECOLUX C-LUX · exlux • ecolux • c-lux 6000 • 6008 • 6400 • 6408 • 6600 • 6608 • 6500 innovative explosion protection by r. stahl 1-800-782-4357

Parts and Accessories

INNOVATIVE EXPLOSION PROTECTION by R. STAHL 1-800-782-4357B15

L I G H T I N G

B16

Use only the following original spare parts and accessories, any others would invalidate the certification and warranty.

Item Image Description Catalog Number

Lens for light fixture C-LUX 6500/1 61 000 01 05 0

Lamp Holder snap-in lamp holder for C-LUX 6500/1 385 647 0

Socket Wrench To operate the central 81 980 05 40 0 1/2'' (13mm) interlock mechanism

Conduit Hub 3/4'' NPT For conduit entries on small and long side 82 959 39 37 0

Sealing Ring 3/4'' For above Hub P/N 82 959 39 37 0 515 795 0

Close-Up Plug Close-Up Plug M25 82 900 09 59 08290/3 M25 x 1.5