Upload
others
View
2
Download
0
Embed Size (px)
Citation preview
3
9
4
0
4
1
41
41
4
2
42
42
4
3
4
3
43
16
16
16
25.5
210 211 223 224
217
216
215
214
213
212222
221
220
219
218
4
4
43
4
3
43
EXISTINGDEVELOPMENT
ROAD AB2
B2B2
B2
2.0m D.E
2.0m D.E
14
32
12.5
10.5
28
28.4
25.5
12.5
29.8
29.9
8.5
12.8
19.5
14
13.8
29.6
29.5
29.3
29.4
29.2
29.1
28.8
28.9
25.6
28.7
14
22
1414
114.2
19
10.5
22
10.5
22
10.5
12.512.5
22
14
14
32
14
32
14
16
16 14
13
3232
13
12.5
12.5
14 13
13
12.5
12.5
14
14
14
14
14
14
12.5
12.5
10.5
22
10.5
10.5
10.5
22
11
4.219
14
18
14
4.2
21
11
28
21
2828
12.5
12.5
12.5
14
1414
4.211
13.9 12.5
12.514
14
14
14
12.5
12.5
12.5
12.5
12.5
12.5
14
14
12.5
12.5
12.5
12.5
14
1414
14
14
14
14
12.5
12.5
12.5
14
28
12.5
12.5
12.5
11.5
12.512.5
12.5
14.5
4.3
18
21
14
21
114.2
14
12.9
B2
B2
B2B2
B2
B2
B2
B2 B2B2
B2
B2
32 32 32 32 32 32
322828282828282828
DAM
OPEN DRAIN
OPEN DRAIN
SEALED TRACK
DAM
Ex.JP
Ex.GP
Ex. Ø300 RCP
E
x
.
Ø
3
0
0
R
C
P
Ex. Ø
300
RC
P
ROAD C
ROAD
B
ROAD
D
ARTEMIS DRIVE
ROAD
B
ROAD C
B2B2
FUTURESTAGE 2
FUTURESTAGE 2
FUTUREDEVELOPMENT
BY OTHERSEXISTING
DEVELOPMENT
22 22
32
EXITING SEALED TRACK TO BEPROTECTED DURING CONSTRUCTION
EXISTING VEGETATION TO BE TRIMMED/REMOVED. CONTRACTOR TO LIAISE WITH
SUPERINTENDENT TO DETERMINE EXTENTOF REMOVAL/ TRIMMING
EXISTING TREE TO BE REMOVEDIF APPROVED. CONTRACTOR TOLIAISE WITH COUNCIL APPROVEDARBORIST TO DETERMINE EXTENTOF REMOVAL / TRIMMING
EXISTING FENCE TO BEREMOVED AND TIED TO
NEAREST POST
EXISTING FENCE TO BE REMOVEDAND TIED TO NEAREST POST
EXISTING FENCE TO BEREMOVED AND TIED TONEAREST POST
EXISTING DAM TO BE DRAINED,DE-SLUDGED, COMPACTED &
FILLED TO LEVEL 1 SUPERVISION
RE-SHAPE & GRADEEXISTING OPEN DRAIN
TO ACCOMMODATENEW SWALE DRAIN
REMOVE TEMPORARY TURNAROUND 200mmTHICK CLASS 3 FCR 9.0m MINIMUM RADIUS &
AND ROAD CLOSED & HAZARD SIGN
REMOVE CONCRETE EDGE STRIPINCLUDING AG DRAIN
REMOVE TEMPORARY TURNAROUND 200mmTHICK CLASS 3 FCR 9.0m MINIMUM RADIUS &
AND ROAD CLOSED & HAZARD SIGN
REMOVE CONCRETE EDGE STRIPINCLUDING AG DRAIN
CONSTRUCT TEMPORARY TURNAROUND200mm THICK CLASS 3 FCR 9.0m MINIMUM
RADIUS & SUPPLY AND INSTALL ROADCLOSED & HAZARD SIGN
SUPPLY AND INSTALL CONCRETEEDGE STRIP AS SPECIFIED
INCLUDING AG DRAIN
CONSTRUCT NEWSTORMWATER GP ANDCONNECT NEW STORMWATERPIPE AND MAKE GOOD TOCOUNCIL STANDARDS
CONNECT NEW STORMWATERTO EX. STORMWATER STUBS
CONNECT NEW STORMWATERTO EX. STORMWATER STUB
1.00m
1.00m
M2
M2
B2
B2
12.5
12.5
29
14
4.2
25
14
4.2
11
32
32
10.5
277.1
15.8
SUPPLY AND INSTALL CONCRETEEDGE STRIP AS SPECIFIEDINCLUDING AG DRAIN AND ROADCLOSED & HAZARD SIGN
SUPPLY AND INSTALL CONCRETEEDGE STRIP AS SPECIFIEDINCLUDING AG DRAIN AND ROADCLOSED & HAZARD SIGN
8.6R 8.6R
8.6R 8.6R
8.6R 8.6R
FUTURESTAGE 2
1.00m
1.00m
SEWER OUTFALL TODISCHARGE INTO PROPOSEDSOUTH EAST WATERAPPROVED PUMP STATION.(REFER TO SEWER PLANS).
149
294m²
414m²416m²
141
101
350m²
275m²
122
121
111110
123
109
124
108
125
107106
127 126128
104 105
129130
103102
131132
112
117
113
118
120
119
142
143
144
140139138137136135134133 151150
145
146
147
148
412m²362m²410m²413m²
390m²
383m²
290m²
397m²394m²
303m²303m²
290m²
417m²
360m²406m²367m² 408m²
294m²
350m²350m² 350m²392m² 350m²350m²350m²350m² 350m² 350m²
448m²400m² 448m²448m²416m²448m²400m² 512m²448m²448m²
275m²
231m²
231m²
231m²
231m²
114
115
116
152
489m²
400m²
443m²
388m²
EX
EX
EX
EX
EX
EX
EX
EX
EX
EX
EX EX EX EX EX EX EX
EX EX EX EX EX EX EX EX
EX
EX
EX41.261
EX40.520
EX40.418
EX41.612
EX40.986EX41.068
EX40.764
EX39.702
EX40
.844
EX40
.000
EX40
.000
EX42
.808
EX43
.070
EX40
.607
EX40
.263
EX40
.219
EX40
.418
EX40
.655
EX41
.264
EX40.795
EX40.448
EX40
.549
EX40.880
EX40.495EX43.153
EX43
.264
EX41
.482
EX41
.463
EX40
.355
EX40.602EX40.754
EX40.639EX40.774
EX40.755EX40.882
EX40.373EX40.454
EX40.872
EX40.528EX40.659
EX40.736
EX43
.290
EX40.284EX40.477
EX40.393EX40.522
EX40.195EX40.521
EX42
.452
EX42
.867
EX42
.142
EX42
.627
EX41
.888
EX42
.362
EX41
.520
EX42
.108
EX41
.257
EX41
.815
EX41
.029
EX41
.505
EX40
.883
EX41
.195
EX40
.963
EX40
.189
EX40
.117
EX41
.041
EX43
.050
EX43
.201
EX42
.910
EX42
.869
EX42
.572
EX42
.273
EX42
.100
EX41
.847
EX41
.750
EX41
.480
EX41
.369
EX41
.201
EX41
.121
EX40
.979
EX40
.874
EX40
.753
EX40
.843
EX40
.779
EX40
.688
EX40
.683EX
43.22
6EX
43.09
4
EX42
.852
EX42
.825
EX42
.186
EX42
.400
EX41
.728
EX42
.065
EX41
.410
EX41
.735
EX41
.135
EX41
.469
EX40
.886
EX41
.229
EX40
.763
EX41
.110
EX40
.742
EX41
.303
EX40
.651
EX41
.475
EX40
.295
EX40
.743
EX40
.316
EX40
.624
EX40
.830
EX41
.392
EX40.184EX40.400EX40.557
EX40.553EX40.753
EX41.482
85.6
AFP02
BFP02
EFP02
DFP02
CFP02
Vertical
HorizontalScale
0
01:500,A1
5 10 15 20 25
5 10 15 20 25
THE LOCATION OF SERVICES ARE APPROXIMATE ONLYAND THEIR EXACT POSITION SHOULD BE PROVEN ONSITE. NO GUARANTEE IS GIVEN THAT ALL EXISTINGSERVICES ARE SHOWN.SPECIAL CONSIDERATION
SHOULD BE GIVEN TO CONSTRUCTION PROCEDURESUNDER OVERHEAD ELECTRICITY TRANSMISSION LINES.
BEWARE OF UNDERGROUND/OVERHEAD SERVICESWARNING
SHEET INDEXSHEET NO. REVISION DESCRIPTION
1 C FUNCTIONAL LAYOUT PLAN2 C TYPICAL SECTIONS3 C TURNING MOVEMENTS (1)4 C TURNING MOVEMENTS (2)5 C PARKING, SIGNAGE AND LINEMARKING PLAN6 C EXISTING FEATURES AND TREE REMOVAL PLANDATEREV. AMENDMENTS APP'D REV.
PM
MELWAYS:
FILE: J:\12dS_WorkSpace\data\AUMELSQL01\116501_418\PM02 DESIGN\G01 DESIGN\ACAD\116501FP00.dwg LAYOUT: FP1-01 PLOTTED BY: Nathan Miratana PLOT DATE: 7/5/2019 12:06 PM
SHEET No.
C 2018 LD Eng Pty Ltd
OF
POS No.:
DESIGNED
CHECKED
STATUS:
AUTHORISED
Land Development Engineering
Level 1, 1-5 Nantilla Road
Notting Hill, Vic 3168
Ph: 03 9562 7424
ldeng.com.au
116501FP01 C
BALLARTO RD (1405)CRANBOURNE EAST
CITY OF CASEYFUNCTIONAL LAYOUT PLAN
B.SAUNDERS15.02.19
S.A.H.5.03.2019
PS830147PA ISSUE TO COUNCIL 27.03.2019S.A.H.B DRAINAGE AND SEWER AMENDED LOTS 101 - 111 30.04.2019S.A.H.C ELECTRICAL KIOSK ADDED TO LOT 111 07.05.2019S.A.H.
1 6PRELIMINARY
134 H10
B. HEYME
5.03.2019N.MIRATANA
LEGEND:EXISTING WATER MAINEXISTING RECYCLED WATER MAINEXISTING UNDERGROUND ELECTRICITYEXISTING OVERHEAD ELEC & POLEEXISTING TELSTRA & SERVICE PITEXISTING OPTIC FIBREEXISTING GAS MAINEXISTING FENCEEXISTING SEWER & MANHOLEEXISTING SEWER RISING MAIN
EXISTING STORMWATER DRAIN & PIT
EXISTING HOUSE DRAINEXISTING SURFACE CONTOUR MINOREXISTING SURFACE CONTOUR MAJOREXISTING TOP OF BATTEREXISTING TOE OF BATTEREXISTING KERBEXISTING FOOTPATHEXISTING FILL LEVELEXISTING SURFACE LEVELEXISTING BUILDINGEXISTING SIGN AND POSTEXISTING PERMANENT SURVEY MARKROAD RESERVELOT BOUNDARYEASEMENTKERB & CHANNEL + TYPESAWCUT PAVEMENTCONCRETE EDGE STRIPLIMIT OF ROAD WORKSALLOTMENT NUMBERROAD CHAINAGE
ROAD TP CHAINAGE
SET-OUT POINT
FINISHED SURFACE CONTOUR MINORFINISHED SURFACE CONTOUR MAJORFINISHED SURFACE LEVELTOP/TOE OF BATTER LEVELPROPOSED WATER MAINPROPOSED RECYCLED WATER MAINPROPOSED ELECTRICITYPROPOSED TELSTRAPROPOSED OPTIC FIBRE CONDUITPROPOSED GAS MAINPROPOSED SEWERPROPOSED SEWER RISING MAIN
PROPOSED STORMWATER DRAIN & PIT
PROPOSED HOUSE DRAINPROPOSED DRAINAGE INLETAUTHORITY DRAIN & PIT
PIT NUMBER
PROPOSED FOOTPATH
PROPOSED DRIVEWAY
PROPOSED INDUSTRIAL DRIVEWAY
GAS & WATER CONDUITPROPOSED AG DRAIN & FLUSHER PITPROPOSED CATCH DRAINPROPOSED SWALE DRAIN5 YEAR FLOW ARROW100 YEAR FLOW ARROWTEMPORARY BENCH MARK (TBM)
PROPOSED PERMANENT SURVEY MARK
PROPOSED BOLLARDPROPOSED LIGHT & POLEPROPOSED ESTATE FENCEPROTECTIVE TREE FENCINGPROPOSED TOP OF BATTERPROPOSED TOE OF BATTERRIDGE / CHANGE OF GRADEPROPOSED SLEEPER RETAINING WALLPROPOSED ROCK RETAINING WALL
PARKING BAY/PAVED AREA
CONCRETE PAVEMENT THRESHOLD
ROCK BEACHING
CRUSHED ROCK TURNAROUND
EXCAVATION GREATER THAN 200mm
FILLING GREATER THAN 200mm
PAVEMENT TO BE REMOVED
Ex 450Ø
H
168.90169.00
EX158.664
SM2
52CH20.06
TPCh116.57
R2
168.90169.00
FS158.385T167.15
H
X
O O O
®
25.50m ROAD RESERVE11.20m CARRIAGEWAY (WITH PARKING BAYS)
Road A
DRAI
NAGE
DRAI
NAGE
25.50
1.80
2.20
2.65
GAS
NON DRINKING WATER
WATER
2.85
3.60TELCOELECTRICITY
3.50 3.50
11.20
3.00BIKE PATH
VERGE
1 IN 10 (MAX)1 IN 30 (MIN)
1.50PATH
1 IN 40
0.05
1 IN 40
0.05
4.50
1.50PATH
VERGE
0.60B2
0.60B2
2.10 2.10
CARRIAGEWAY
PARKING BAY PARKING BAY
1 IN 30 1 IN 30
BUILD
ING
LINE
BUI
LDIN
G LIN
E
1 IN 10 (MAX)1 IN 30 (MIN)
16.00m ROAD RESERVE7.30m CARRIAGEWAY
Road D
25.50m ROAD RESERVE
DRAI
NAGE
25.50
1.80
2.20
2.65
GAS
NON DRINKING WATER
WATER
1.00SEWER
3.50 3.50
7.00
1.50PATH
1 IN 40
0.05
6.60VERGE
0.60B2
0.60B2
CARRIAGEWAY
1 IN 30 1 IN 30
BUILD
ING
LINE
1 IN 10 (MAX)1 IN 30 (MIN)
7.00m CARRIAGEWAY Road A
9.80
AFP01
SECTIONSCALE 1 : 100
BFP01
SECTIONSCALE 1 : 100 E
FP01SECTIONSCALE 1 : 100
BUILD
ING
LINE
16.00m ROAD RESERVE7.30m CARRIAGEWAY
Road B CFP01
SECTIONSCALE 1 : 100
16.00m ROAD RESERVE7.30m CARRIAGEWAY
Road C DFP01
SECTIONSCALE 1 : 100
16.00
4.20
2.65VERGE1.50PATH
4.50
1.50 2.65
1 IN 10 (MAX)1 IN 30 (MIN)
VERGE
PATH
1 IN 40
0.60B2
1 IN 30
0.60B2
1 IN 30
7.30
3.653.65CARRIAGEWAY
DRAI
NAGE
DRAI
NAGE
1 IN 40
0.05 0.05
1.852.35
TELCOELECTRICITY
1.80
2.30
2.80
GAS
NON DRINKING WATER
1.00SEWER
BUILD
ING
LINE
BUILD
ING
LINE
1 IN 10 (MAX)1 IN 30 (MIN)
1.00 SEWER
16.00
4.20
2.65VERGE
1.50PATH
4.50
1.502.65
1 IN 10 (MAX)1 IN 30 (MIN)
VERGE
PATH
1 IN 40
0.60B2
1 IN 30
0.60B2
1 IN 30
7.30
3.65 3.65CARRIAGEWAY
DRAI
NAGE
DRAI
NAGE
1 IN 40
0.050.05
1.852.35
TELCOELECTRICITY
1.80
2.30
2.80
GAS
NON DRINKING WATER
WATER
1.00 SEWER
BUILD
ING
LINE
BUILD
ING
LINE
1 IN 10 (MAX)1 IN 30 (MIN)
1.00SEWER
16.00
4.20
2.65VERGE1.50PATH
4.50
1.50
1 IN 10 (MAX)1 IN 30 (MIN)
VERGE
PATH
1 IN 40
0.60B2
1 IN 30
0.60B2
1 IN 30
7.30
3.653.65CARRIAGEWAY
DRAI
NAGE
DRAI
NAGE
1 IN 40
0.05 0.05
1.852.35
TELCOELECTRICITY
1.80
2.30
2.80
GAS
NON DRINKING WATER
WATER
1.00SEWER
BUILD
ING
LINE
BUILD
ING
LINE
1 IN 10 (MAX)1 IN 30 (MIN)
1.00 SEWER2.85
3.60TELCOELECTRICITY
3.00BIKE PATH
VERGE
1 IN 10 (MAX)1 IN 30 (MIN) 1 IN 40
0.05
1.50PATH
11.90
1 IN 40
Vertical
HorizontalScale
1 2 3 4 50
01:100,A1
1 2 3 4 5
Road A 25.50 1.00* S 1.80 S 2.20 S 2.65 N 3.60 S 1.00* N 2.85 S 1.00* VARIES G,NDW,DW & E,TRoad B 16.00 1.00* W 1.80 W 2.30 W 2.80 E 2.35 W 1.00* E 1.85 W 1.00* W4.35/E4.05 G,NDW,DW & E,TRoad C 16.00 1.00* N 1.80 N 2.30 N 2.80 S 2.35 N 1.00* S 1.85 N 1.00* N4.35/S4.05 G,NDW,DW & E,TRoad D 16.00 1.00* W 1.80 W 2.30 W 2.80 E 2.35 W 1.00* E 1.85 W 1.00* W4.35/E4.05 G,NDW,DW & E,T
SERVICE OFFSET TABLE
ROAD NAMEROAD
RESERVEWIDTH
TREEGAS
WATER ELECTRICITY COMMUNICATIONS/ NBN
BACK OF KERB SHAREDTRENCHINGNDW DW CABLES POLES CABLES PITS
SIDE OFFSET SIDE OFFSET SIDE OFFSET SIDE OFFSET SIDE OFFSET SIDE OFFSET SIDE OFFSET
DATEREV. AMENDMENTS APP'D REV.
PM
MELWAYS:
FILE: J:\12dS_WorkSpace\data\AUMELSQL01\116501_418\PM02 DESIGN\G01 DESIGN\ACAD\116501FP00.dwg LAYOUT: FP2-01 PLOTTED BY: Nathan Miratana PLOT DATE: 7/5/2019 12:06 PM
SHEET No.
C 2018 LD Eng Pty Ltd
OF
POS No.:
DESIGNED
CHECKED
STATUS:
AUTHORISED
Land Development Engineering
Level 1, 1-5 Nantilla Road
Notting Hill, Vic 3168
Ph: 03 9562 7424
ldeng.com.au
116501FP02 C
BALLARTO RD (1405)CRANBOURNE EAST
CITY OF CASEY TYPICAL SECTIONS
B.SAUNDERS15.02.19
S.A.H.5.03.2019
PS830147PA ISSUE TO COUNCIL 27.03.2019S.A.H.B DRAINAGE AND SEWER AMENDED LOTS 101 - 111 30.04.2019S.A.H.C ELECTRICAL KIOSK ADDED TO LOT 111 07.05.2019S.A.H.
2 6PRELIMINARY
134 H10
B. HEYME
5.03.2019N.MIRATANA
1. TELSTRA AND ELECTRICITY CABLES TO BE CONSTRUCTED IN A COMMON TRENCH IN ACCORDANCE WITH ELECTRICITY AUTHORITY STANDARD DRG's.2. GAS AND WATER MAINS TO BE CONSTRUCTED IN A COMMON TRENCH.3. * = OFFSET FROM BACK OF KERB
LEGEND:EXISTING WATER MAINEXISTING RECYCLED WATER MAINEXISTING UNDERGROUND ELECTRICITYEXISTING OVERHEAD ELEC & POLEEXISTING TELSTRA & SERVICE PITEXISTING OPTIC FIBREEXISTING GAS MAINEXISTING FENCEEXISTING SEWER & MANHOLEEXISTING SEWER RISING MAIN
EXISTING STORMWATER DRAIN & PIT
EXISTING HOUSE DRAINEXISTING SURFACE CONTOUR MINOREXISTING SURFACE CONTOUR MAJOREXISTING TOP OF BATTEREXISTING TOE OF BATTEREXISTING KERBEXISTING FOOTPATHEXISTING FILL LEVELEXISTING SURFACE LEVELEXISTING BUILDINGEXISTING SIGN AND POSTEXISTING PERMANENT SURVEY MARKROAD RESERVELOT BOUNDARYEASEMENTKERB & CHANNEL + TYPESAWCUT PAVEMENTCONCRETE EDGE STRIPLIMIT OF ROAD WORKSALLOTMENT NUMBERROAD CHAINAGE
ROAD TP CHAINAGE
SET-OUT POINT
FINISHED SURFACE CONTOUR MINORFINISHED SURFACE CONTOUR MAJORFINISHED SURFACE LEVELTOP/TOE OF BATTER LEVELPROPOSED WATER MAINPROPOSED RECYCLED WATER MAINPROPOSED ELECTRICITYPROPOSED TELSTRAPROPOSED OPTIC FIBRE CONDUITPROPOSED GAS MAINPROPOSED SEWERPROPOSED SEWER RISING MAIN
PROPOSED STORMWATER DRAIN & PIT
PROPOSED HOUSE DRAINPROPOSED DRAINAGE INLETAUTHORITY DRAIN & PIT
PIT NUMBER
PROPOSED FOOTPATH
PROPOSED DRIVEWAY
PROPOSED INDUSTRIAL DRIVEWAY
GAS & WATER CONDUITPROPOSED AG DRAIN & FLUSHER PITPROPOSED CATCH DRAINPROPOSED SWALE DRAIN5 YEAR FLOW ARROW100 YEAR FLOW ARROWTEMPORARY BENCH MARK (TBM)
PROPOSED PERMANENT SURVEY MARK
PROPOSED BOLLARDPROPOSED LIGHT & POLEPROPOSED ESTATE FENCEPROTECTIVE TREE FENCINGPROPOSED TOP OF BATTERPROPOSED TOE OF BATTERRIDGE / CHANGE OF GRADEPROPOSED SLEEPER RETAINING WALLPROPOSED ROCK RETAINING WALL
PARKING BAY/PAVED AREA
CONCRETE PAVEMENT THRESHOLD
CONCRETE PAVEMENT
ROCK BEACHING
CRUSHED ROCK TURNAROUND
EXCAVATION GREATER THAN 200mm
FILLING GREATER THAN 200mm
PAVEMENT TO BE REMOVED
Ex 450Ø
H
168.90169.00
EX158.664
SM2
52CH20.06
TPCh116.57
R2
168.90169.00
FS158.385T167.15
H
X
O O O
®
ROAD
B
ROAD
D
B2 B2
ROAD C
B2B2
M2
M2
8.6R8.6R
8.6R 8.6R
149
141
122
123124 118
119
142
150
147
148
ROAD
B
ROAD
D
B2 B2
ROAD C
B2B2
M2
M2
8.6R8.6R
8.6R 8.6R
149
141
122
121
123 117118
120
119
151150
148
ROAD A
ROAD
B
B2
B2
B2
B2
B2
B2
8.6R 8.6R
111110109 112 113
Vertical
HorizontalScale
0
01:250,A1
2.5 5 7.5 10 12.5
2.5 5 7.5 10 12.50
ROAD A25.5m ROAD RESERVE
SCALE 1 : 250
ROAD C16.00m ROAD RESERVE
SCALE 1 : 250
DATEREV. AMENDMENTS APP'D REV.
PM
MELWAYS:
FILE: J:\12dS_WorkSpace\data\AUMELSQL01\116501_418\PM02 DESIGN\G01 DESIGN\ACAD\116501FP00.dwg LAYOUT: FP3-01 PLOTTED BY: Nathan Miratana PLOT DATE: 7/5/2019 12:06 PM
SHEET No.
C 2018 LD Eng Pty Ltd
OF
POS No.:
DESIGNED
CHECKED
STATUS:
AUTHORISED
Land Development Engineering
Level 1, 1-5 Nantilla Road
Notting Hill, Vic 3168
Ph: 03 9562 7424
ldeng.com.au
116501FP03 C
BALLARTO RD (1405)CRANBOURNE EAST
CITY OF CASEY TURNING MOVEMENTS (1)
B.SAUNDERS15.02.19
S.A.H.5.03.2019
PS830147PA ISSUE TO COUNCIL 27.03.2019S.A.H.B DRAINAGE AND SEWER AMENDED LOTS 101 - 111 30.04.2019S.A.H.C ELECTRICAL KIOSK ADDED TO LOT 111 07.05.2019S.A.H.
3 6PRELIMINARY
134 H10
B. HEYME
5.03.2019N.MIRATANA
8.8
1.5 5
Service Vehicle (8.8 m)Overall Length 8.800mOverall Width 2.500mOverall Body Height 4.300mMin Body Ground Clearance 0.427mTrack Width 2.500mLock-to-lock time 4.00sCurb to Curb Turning Radius 12.500m
5.2
0.95 3.05
Passenger vehicle (5.2 m)Overall Length 5.200mOverall Width 1.940mOverall Body Height 1.804mMin Body Ground Clearance 0.295mTrack Width 1.840mLock-to-lock time 4.00sCurb to Curb Turning Radius 6.300m
ROAD
B
ROAD
D
B2 B2
DAM
B2B2
M2
M2
8.6R8.6R
8.6R 8.6R
149
141
122
123124125
119
142
140147
148
RCP
ROAD A
ROAD
B
ROAD AB2
B2
B2
B2
B2
B2
ROAD
B
8.6R 8.6R
121
111110109 112 113
120
412m²362m² 397m²394m²360m²
294m²
Vertical
HorizontalScale
0
01:250,A1
2.5 5 7.5 10 12.5
2.5 5 7.5 10 12.50
ROAD C25.50m ROAD RESERVE
SCALE 1 : 250
ROAD A16.00m ROAD RESERVE
SCALE 1 : 250
DATEREV. AMENDMENTS APP'D REV.
PM
MELWAYS:
FILE: J:\12dS_WorkSpace\data\AUMELSQL01\116501_418\PM02 DESIGN\G01 DESIGN\ACAD\116501FP00.dwg LAYOUT: FP3-02 PLOTTED BY: Nathan Miratana PLOT DATE: 7/5/2019 12:06 PM
SHEET No.
C 2018 LD Eng Pty Ltd
OF
POS No.:
DESIGNED
CHECKED
STATUS:
AUTHORISED
Land Development Engineering
Level 1, 1-5 Nantilla Road
Notting Hill, Vic 3168
Ph: 03 9562 7424
ldeng.com.au
116501FP04 C
BALLARTO RD (1405)CRANBOURNE EAST
CITY OF CASEY TURNING MOVEMENTS (2)
B.SAUNDERS15.02.20
S.A.H.5.03.2019
PS830147PA ISSUE TO COUNCIL 27.03.2019S.A.H.B DRAINAGE AND SEWER AMENDED LOTS 101 - 111 30.04.2019S.A.H.C ELECTRICAL KIOSK ADDED TO LOT 111 07.05.2019S.A.H.
4 6PRELIMINARY
134 H10
B. HEYME
5.03.2019N.MIRATANA
EXISTINGDEVELOPMENT
ROAD AB2
B2 B2
B2
B2
B2
B2B2
B2
B2
B2
B2 B2B2
B2
B2
ROAD C
ROAD
B
ROAD
DB2B2
FUTURESTAGE 2
FUTURESTAGE 2
FUTUREDEVELOPMENT
BY OTHERS
EXISTINGDEVELOPMENT
M2
M2
B2
B2
FUTURESTAGE 2
149
141
101
122
121
111110
123
109
124
108
125
107106
127 126128
104 105
129130
103102
131132
112
117
113
118
120
119
142
143
144
140139138137136135134133 151150
145
146
147
148
114
115
116
152
Vertical
HorizontalScale
0
01:500,A1
5 10 15 20 25
5 10 15 20 25DATEREV. AMENDMENTS APP'D REV.
PM
MELWAYS:
FILE: J:\12dS_WorkSpace\data\AUMELSQL01\116501_418\PM02 DESIGN\G01 DESIGN\ACAD\116501FP00.dwg LAYOUT: FP4-01 PLOTTED BY: Nathan Miratana PLOT DATE: 7/5/2019 12:06 PM
SHEET No.
C 2018 LD Eng Pty Ltd
OF
POS No.:
DESIGNED
CHECKED
STATUS:
AUTHORISED
Land Development Engineering
Level 1, 1-5 Nantilla Road
Notting Hill, Vic 3168
Ph: 03 9562 7424
ldeng.com.au
116501FP05 C
BALLARTO RD (1405)CRANBOURNE EAST
CITY OF CASEY PARKING, SIGNAGE AND
LINEMARKING PLAN
B.SAUNDERS15.02.19
S.A.H.5.03.2019
PS830147PA ISSUE TO COUNCIL 27.03.2019S.A.H.B DRAINAGE AND SEWER AMENDED LOTS 101 - 111 30.04.2019S.A.H.C ELECTRICAL KIOSK ADDED TO LOT 111 07.05.2019S.A.H.
5 6PRELIMINARY
134 H10
B. HEYME
5.03.2019N.MIRATANA
SIGN LEGEND
GIVE
WAY
R1-2A
ROAD CLOSED
R1-2ASIGN
R1-2ASIGN
R1-2ASIGN
T2 AND D5 SIGN
R1-2ASIGN
R1-2ASIGN
3
9
4
0
4
1
41
41
4
2
42
42
4
3
4
3
43
4
4
43
4
3
43
C
/T
V
O
L.10355 F
O
L.953
DAM
OPEN DRAIN
OPEN DRAIN
SEALED TRACK
DAM
Ex.JP
Ex.GP
Ex. Ø300 RCP
E
x
.
Ø
3
0
0
R
C
P
Ex. Ø
300
RC
P
RE-SHAPE & GRADEEXISTING OPEN DRAIN TOACCOMMODATE NEWSWALE DRAIN
TEMPORARY SWALE DRAIN TO DIRECTOVERLAND FLOW SOUTH THROUGHPROPOSED DEVELOPMENT
Vertical
HorizontalScale
0
01:500,A1
5 10 15 20 25
5 10 15 20 25DATEREV. AMENDMENTS APP'D REV.
PM
MELWAYS:
FILE: J:\12dS_WorkSpace\data\AUMELSQL01\116501_418\PM02 DESIGN\G01 DESIGN\ACAD\116501FP00.dwg LAYOUT: FP5-01 PLOTTED BY: Nathan Miratana PLOT DATE: 7/5/2019 12:06 PM
SHEET No.
C 2018 LD Eng Pty Ltd
OF
POS No.:
DESIGNED
CHECKED
STATUS:
AUTHORISED
Land Development Engineering
Level 1, 1-5 Nantilla Road
Notting Hill, Vic 3168
Ph: 03 9562 7424
ldeng.com.au
116501FP06 C
BALLARTO RD (1405)CRANBOURNE EAST
CITY OF CASEYEXISTING FEATURES AND
TREE REMOVAL PLAN
B.SAUNDERS15.02.19
S.A.H.5.03.2019
PS830147PA ISSUE TO COUNCIL 27.03.2019S.A.H.B DRAINAGE AND SEWER AMENDED LOTS 101 - 111 30.04.2019S.A.H.C ELECTRICAL KIOSK ADDED TO LOT 111 07.05.2019S.A.H.
6 6PRELIMINARY
134 H10
B. HEYME
5.03.2019N.MIRATANA
EXISTING DAM. DRAINAND DE-SLUDGE
EXITING SEALED TRACK TO BEPROTECTED DURING CONSTRUCTION
EXISTING JUNCTION PIT AND DRAINAGELINE TO REMAIN. CONTRACTOR TOPROTECT DURING CONSTRUCTION
EXISTING OPEN DRAIN TO BEDRAINED AND DE-SLUDGED
EXISTING FENCE TO BE REMOVEDAND TIED TO NEAREST POST
EXISTING VEGETATION TO BE TRIMMED /REMOVED. CONTRACTOR TO LIAISE WITHSUPERINTENDENT TO DETERMINE EXTENTOF REMOVAL / TRIMMING
EXISTING TREE TO BE REMOVED IFAPPROVED. CONTRACTOR TO LIAISEWITH COUNCIL APPROVED ARBORISTTO DETERMINE EXTENT OF REMOVAL /TRIMMING
EXISTING FENCE TO BE REMOVEDAND TIED TO NEAREST POST
EXISTING FENCE TO BE REMOVEDAND TIED TO NEAREST POST
EXISTING FENCE TO BE REMOVEDAND TIED TO NEAREST POST