1 0 . 4. .• ......„... NSW GOVERNMENT Health Certificate of Accreditation Sewage Management Facility Aerated Wastewater System Treatment This Certificate of Accreditation is issued by the Secretary of the NSW Ministry of Health pursuant to Clause 41(1) of the Local 6overnment (6eneral) Regulation 2005. System: Aqua-Nova 10EP AWT5 Manufacturer: Everhard Industries Ply Ltd Of: 405 Newman Road, Geebung, Qld, 4034 The Aqua-Nova 10EP AWTS as described in Schedule 1, has been accredited as a sewage management facility for use in a single domestic premises in NSW This accreditation is subject to the conditions of accreditation and permittea' uses specified in Schedule 2. Z a_____ A/Director, Environmental Health for Secretary (delegation PH335) Issued: 16 November 2014 Certificate No: AWT5 006 Expires: 31 December 2017

Everhard Industries - Everhard Industries - 0„...DERHARD INDUSTRIES PTT LTD ACCEPTS NO LIADLITY CD RESPONSIDLITY TO THE USSR GO MN OTTER PERSON OIR DIRTY ASH RESPECT TO ANY UABUTY

  • Upload
    others

  • View
    7

  • Download
    0

Embed Size (px)

Citation preview

  • 10. 4. .• ......„... NSWGOVERNMENT Health

    Certificate of Accreditation Sewage Management Facility

    Aerated Wastewater System Treatment

    This Certificate of Accreditation is issued by the Secretary of the NSW Ministry of Health pursuant to Clause 41(1) of the Local

    6overnment (6eneral) Regulation 2005.

    System: Aqua-Nova 10EP AWT5

    Manufacturer: Everhard Industries Ply Ltd

    Of: 405 Newman Road, Geebung, Qld, 4034

    The Aqua-Nova 10EP AWTS as described in Schedule 1, has been accredited as a sewage management facility for use in a single domestic

    premises in NSW This accreditation is subject to the conditions of accreditation and permittea' uses specified in Schedule 2.

    Z a_____

    A/Director, Environmental Health for Secretary (delegation PH335)

    Issued: 16 November 2014 Certificate No: AWT5 006 Expires: 31 December 2017

  • Schedule 1: Specification

    The Aqua-Nova 10 EP Aerated Wastewater Treatment System (AWTS) is designed to treat the wastewater from a residential dwelling occupied by a maximum of 10 persons. The Aqua-Nova 10 EP AWTS is contained in vertical axis type cylindrical precast concrete or injection moulded polypropylene septic tanks and collection wells each with design capacities as set out below.

    The Aqua-Nova 10 EP AWTS is assembled in the following configurations:

    Design capacities Polymer 2 x 3000L 80202

    polymer 2 x 3900L 80203

    concrete 2 x 3000L

    concrete 2 x 3900L

    concrete 2x 3900L

    primary 3000 L 4175 L 3000 L 3587 L 3351 L sedimentation

    • partition yes yes yes yes yes

    secondary 3000 L 3340 L 3075 L 3490 L 3266 L treatment • aeration chamber 1985 L 3010 L 2253 L 2630 L 2443 L • sedimentation • irrigation 430 L 430 L 430 L 430 L 430 L

    393 L 393 L 393 L 393 L 393 L

    emergency storage 1000 L 1052 L 1095 L 1040 L 1040 L

    operational water level (mm) (mm) (mm) (mm) (mm)

    • primary • secondary 1385 1770 1510 1500 1370

    1350 1730 1510 1400 1335

    • A chlorine disinfection unit is installed on the outlet of the clarifying chamber. • Air is supplied to the contact aeration chamber by a Nitto LA80-A air blower or equivalent, producing an

    airflow of a nominal 100 litres/minute at 1.3 m water depth. • A Davey model D-25A submersible irrigation pump or equivalent is installed in the irrigation chamber.

    Schedule 2: Conditions of Accreditation

    1.0 General

    1.1

    For each installation the owner/occupier of the premises shall make an application to the local council to install an Aqua-Nova 10EP AWTS as a sewage management facility in accordance with Section 68, Part C of the Local Government Act 1993 and Clause 26 of the Local Government (General) Regulation 2005.

    1.2 The Aqua-Nova 10EP AWTS shall be supplied, constructed and installed in accordance with the design as submitted and accredited by the NSW Ministry of Health.

    1.3 Any modification or variations to the accredited design of the Aqua-Nova 10EP AWTS shall be submitted for separate consideration and variation of the Certificate of Accreditation by the Secretary of the NSW Ministry of Health.

    Page 1 of 3

  • 1.4 Each Aqua-Nova 10EP AWTS shall be permanently and legibly marked on a non-corrosive metal plaque or equivalent, attached to the lid with the following information: • The brand name of the system; • The manufacturer's name or registered trademark; • The month and year of manufacture.

    1.5 The manufacturer shall supply with each Aqua-Nova 10EP AWTS an owner's manual, which sets out the care, operation, maintenance and on-going management requirements of the system.

    1.6 The manufacturer shall provide the following information to each local authority where it is intended to install an AWTS in their area once accreditation from the NSW Ministry has been obtained: • Statement of warranty • Service Report Form • Statement of service life • Engineering Drawings on A3 format • Quality Assurance Certification • Detailed Specifications • Installation Manual • A4 Plans • Service Manual • Accreditation documentation from NSW • Owner's Manual Health.

    2.0 Installation and Commissioning

    2.1 The local council should require that on completion of the installation of the Aqua-Nova 10EP AWTS, the system is inspected and checked by the manufacturer or the manufacturer's agent. The manufacturer or the agent is to certify that the system has been installed and commissioned in accordance with its design, conditions of accreditation and any additional requirements of the Council.

    2.2 The local council should require that all electrical work must be carried out by a licensed electrician and in accordance with the relevant provisions of AS/NZS 3000.

    3.0 Maintenance

    3.1 The local council shall require the owner/occupier of a premises to enter into an annual service contract with a representative of Everhard Industries Pty Ltd or a service contractor or company acceptable to the local council.

    3.2 The Aqua-Nova 10EP AWTS shall be serviced at three monthly intervals in accordance with the details set out in the owner's and service manual.

    3.3 Each three monthly service shall include a check on all mechanical, electrical and functioning parts of the system including: • The chlorinator and replenishment of the disinfectant, • Pumps, air blower, fan or air venturi, • The alarm system, • Slime growth on the filter media, • Operation of the sludge return system, • The effluent irrigation area, • On-site testing for free residual chlorine, pH and dissolved oxygen.

    3.4 The local council should require that a service report sheet, in triplicate, is completed for each service. The original shall be given to the owner, the duplicate forwarded to the local council and the triplicate retained by the service contractor.

    Page 2 of 3

  • 4.0 On-going Management

    4.1 The owner's manual prepared by the manufacturer shall contain a plan for the on-going management of the Aqua-Nova 10EP AVVTS. The plan shall include details of: • the treatment process, • procedures to be followed in the event of a system failure, • emergency contact numbers, • maintenance requirements, • inspection and sampling procedures to be followed as part of the on-going monitoring program

    developed by the local authority.

    4.2 Effluent from the Aqua-Nova 10EP AWTS taken in any random grab sample shall comply with the following standard: • BOD5 less than 30 mg/L • TSS less than 45 mg/L • E. coli less than 100 cfu/100 ml • Free residual chlorine greater than 0.2 and less than 2.0 mg/L

    5.0 Permitted uses

    5.1 The effluent is suitable for re-use for garden purposes by way of any of the forms of irrigation as described in AS/NZS 1547:2012. • above ground spray irrigation; or • surface drip irrigation covered by mulch; or • sub-surface drip irrigation installed at around 100 mm depth.

    Each of the three forms of irrigation is subject to the approval of the local council.

    Page 3 of 3

  • THIS INLET PIPE METHOD NOT TO BE USED UNLESS PIPE IS SUPPORTED SEDIMENTATION CHAMBER

    ACCESS

    COVER INCOMING WASTE FLOW

    DISINFECTION & PUMPOUT CHAMBER

    100mm DIA uPVC RUBBER RING SLIP COUPLING OR PAN COLLAR

    300 1100 1100

    EATMENT TANI'4\, 2 mrn DIA IRRIGATION PIPE

    2100

    AERATION CHAMBER

    100mm DIA RUBBER RING CONNECTOR

    (-PRIMARY TANK

    25mm DIA uPVC SLUDGE RETURN LINE

    100mm DIA INSPECTION OPENINGS

    DRILL 41mm DIA HOLE IN SIDE OF INLET FITTING / TO LOCATE ELBOW OF SLUDGE RETURN

    CONTROL BOX iezz/ REFER ELECTRICIAN INSTRUCTIONS

    50mm DIA VENT

    CONTACT CHLORINATOR

    BACTERIA MEDIA

    SUBMERSIBLE PUMP-REFER TABLE

    \/)

    50mm THK SAND BED

    EFFLUENT APPLICATION/IRRIGATION SYSTEM TO BE AS PER INSTRUCTIONS OR DESIGN PROVIDED WITH EACH INDIVIDUAL SYSTEM.

    EXCAVATION LINE 4.3m x 2,2m x 1.90 DEEP

    TANK INSTALLATION AND PLUMBING TO BE IN ACCORDANCE WITH PLUMBING INSTRUCTIONS PROVIDED WITH SYSTEM.

    APPROVED

    16 NOV 2015

    NSW MINISTRY OF HEALTH

    AMMENDMENT 4 071015 Chlorinator updated, disclaimer added PL APPROVED FOR MANUFACTURE

    PRODUCT CODE No. 80202 80202C 80202D 80106

    DETAILS / DESCRIPTION Davey 25 Pump fitted Claytons Blue Diver 30 Pump fitted Davey 42 Pump fitted Aeration tank only

    DERHARD INDUSTRIES PTT LTD ACCEPTS NO LIADLITY CD RESPONSIDLITY TO THE USSR GO MN OTTER PERSON OIR DIRTY ASH RESPECT TO ANY UABUTY. LOSS, DAMAGE OR MART CAUSED CR ALIECB TO BE CAUSED,

    ESTER ERECTLY CR IORECTLY, BY THE ADOPTION AND/CR UM OF THIS ORAENG. THIS INCUATES, BUT IS NOT RETRICTED TO, orr INTERAUPTION Cf. SERMCES, LOSS OF ACTUAL ea AN1CPKIED MANESS, INCOME, ARO PROMS, 01 CONSECUENTAL DAMAGES ADSN'G FROM. ce ASSOCIMED %1114 THE USE Cf ANY MODULI MACE N ACCORDANCE Vim 11-IS MAING. FuRTHERCRE THS DRAWING RUST NOT BE ASSURED 10 BE PAY EGUIVAIENT IT) CR A su3s1TIVIE FOR, ANY GENERAL USAGE OR PROECT SPECIFIC CF_SICN UNLESS ANALYSED AND APPROVAED AS SUCH BY AN INDEPENDAN1 ALE APPROPRIATELY (NAMED FROFESSImAL. oRRANGNG FOR ANY sum AS,SESEADff IS THE REsPcNsourr OF THE CINTOAlaz FMRCHASING THE PRCOIXT SHOWN IN THIS DR,411NO FRP4 DEWARD musTRIEs PTY LTD, ITS SW USERS REPONSIBLITY TO DrSuRE ARPRCPRIATE PRODUCT B sELECIED I mg Of CORRECT SCALE 141104 UDNO A RAMO IS Min

    DRAWN

    24-2-99

    TITLE

    AQUANOVA AWTS SYSTEM 2 x 3000 It POLYMER 'SOUTH' TANK SYSTEM

    °ROD, No.

    Refer Table

    406 kEPAAH ROAD, CERRO, OLD. 1031 ,

    EVERHARD INDUSTRIES PTY LTD PH :((01) 3.637 6144 FAX : 1 07 ) 3765 2111

    DRAWING NUMBER M — 5108

    DATE MATERI AL MASS

    SCALE

    25

    REVISION

    4 DATE

    071015.

  • 0 CN CN CN

    NS

    W M

    INIS

    TRY

    OF

    HEA

    LTH

    AP

    PR

    OV

    ED

    2200

    30 U1 IN

    TANK INSTALLATION AND PLUMBING TO BE IN ACCORDANCE WITH PLUMBING INSTRUCTIONS PROVIDED WITH SYSTEM.

    THIS INLET PIPE METHOD NOT TO I BE USED UNLESS 1 PIPE IS SUPPORTED!

    • \

    SEHIMENTATION CHAMBER

    DISINFECTION & RUMPOUT CHAMBER EFFLUENT APPLICATION/IRRIGATION SYSTEM TO BE AS PER INSTRUCTIONS OR DESIGN PROVIDED WITH EACH INDIVIDUAL SYSTEM.

    ?r3cha IRRIGATION LINE

    INCOMING WASTE ELI .AERATION CHAMBER

    100 DIA PVC RUBBER RING JOINT

    i02dra RUBBER RING JOINT PIPE

    PRIMARY TANK

    TRFATMFNT TANK)

    EXCAVATION LINE 4.5m x 2.4m x 2,22m DEEP

    LA N VI - W

    CONTROL BOX REFER ELECTRICAL INSTRUCTIONS

    k. 50 dia VENT

    53rrm THK SAND BED

    CR ESS SC TI Rev t PL 090915 Chlar;nolor upgrode.d

    -11 9-T

    J.

    o fl

    --- TANK CASE - MOULD 0-0441 SECURE BEAM TO TANK CASE WITH 2M10 BOLTS EACH END THROUGH 12rnm GRILLED HOLES IN TANK CASE WALL

    -Y- EMERGENCY STORAGE SACKFILL WITH SELECTED FILL IN ACCORDANCE WITH INSTALLATION INSTRUCTIONS

    CONTACT CHLORINATOR

    - BACTERIA MEDIA

    SUBMERSIBLE PUMP - REFER TABLE

    PRODUCT CODE No. DETAILS / DESCRIPTION 10101A DAVEY 25 PUMP FITTED 10101AC CLAYTONS BLUE DIVER 30 PUMP FITTED 10101AD DAVEY 42 PUMP FITTED

    DDITITT MsTrdE5 VIT 60 rar15 00 MLITT ui 6bfuKS1311111 0 TIE LEK lk 7617031166 PERSIA CE BUR CH PESIECT 10 IN IMOD, LOSS, DWE CO TUFT MED UR MECO TO EE CALEI, 0111951(110 103105.11 lIE 0aY11}1 KVF USE CF 1100 If1,46.1115 DfLIEES.BUI Shill F1319.711 10, 693 DiEDREII/i CF sIMES,LIES CF XTUt UI ATMENTED 619,94 DtP.E,AIT PrinTS,111 CCTinE1014 5369095 01956105 FlTrIK UI 05I001E0 kilO SE CF 0707 ROUT TikE Di rr.covia 0111 TES MK. F1.011ERVE, TIES [NM% 1.1131 RH DE MED ID SE al MOEN 170100 SKTENTE F11700141 EBEHL DWI 00 TFATEtT STITIC DES134 VLESS NiTCTHD 4TD UVROvirED As 91D Et to KuiEwiT girmyway ovum FATESSMAVIat 00 loT 510 ASISSYM IS TIE DESPNALITT Cf lIE asvil Um% TIE PAILET SON Di 1103 ROD RN Ein10119 WIRES PTT LTD.IT IS 1161660 DESPDVILIIT 106103906 TIE 'PI:ACME MKT [5 10116161 11 1001 IF Mr 16111 0100 93110300010116 15 tiBLEFJ.

    DEM

    BJD

    TITLADPOSED DEEP INVERT CONCRETE ADANA TREATMENT SYSTEM IN 3°00 CONCRETE TANKS

    ,4PRIYER Till WhILFOIRE

    141E1)1

    32 1.,11,o CONC

    EVERHARD INDUSTRIES PTY LTD 4151014.4S 00,TE Elt45, CLD,409 PH :407 136376444 FA :I 07 13265 2111

    DRAWING NUMBER

    MP — 7187

    DAlE

    14-4-2014 VASS 1911

    125 UNO ximtb.

    as shown

    REVISION CATE

    100 915

  • THIS INLET PIPE 300

    2100 1100 1100 TANK INSTALLATION AND

    PLUMBING TO BE IN

    ACCORDANCE WITH

    PLUMBING INSTRUCTIONS

    PROVIDED WITH SYSTEM.

    METHOD NOT TO I MIN

    BE USED UNLESS

    PIPE IS SUPPORTED

    INCOMING WASTE FLOW

    100 DIA PVC RUBBER

    RING SLIP COUPUNG

    OR PAN COLLAR

    1791

    25d1a IRRIGATION LIN

    100dia RUBBER

    RING CONNECTOR

    MANHOLE COVER

    PRIMARY TANK TREATMENT TANK

    200.0

    PLAN VIEW - TREATMENT SYSTEM SEDIMENTATION CHAMBER

    DISINFECTION & PUMPOUT CHAMBER EFFLUENT APPLICATION/IRRIGATION SYSTEM

    TO BE AS PER INSTRUCTIONS OR DESIGN

    PROVIDED WITH EACH INDIVIDUAL SYSTEM.

    AERATION CHAMBER

    EXCAVATION LINE

    4.3m x 22m x 2.25m DEEP

    NS

    W M

    INIS

    TRY

    OF

    HEA

    L TH

    AP

    PR

    OV

    ED

    80

    380

    50mm THK SAND BED GROUND ANCHOR SECTION - TREATMENT SYSTEM

    GNI

    PRODUCT CODE No.

    80203 80203C 80203D

    DETAILS / DESCRIPTION DAVEY 25 PUMP FITTED CLAYTONS BLUE DIVER 30 PUMP FITTED DAVEY 42 PUMP FITTED

    25mm dia UPVC SLUDGE RETURN LINE

    !Li- .-..\..-----\---:---z-----

    Mimi iimaiml=riangpl j

    EVERHARD INDUSTRIES PTY LTD ACCEPTS NO LIABILITY OR RESPONSIBILITY TO THE USER OR ANY OTHER PERSON OR ENTITY WITH RESPECT TO ANY LIABILITY, LOSS, DAMAGE OR INJURY CAUSED OR ALLEGED TO BE CAUSED EITHER DIRECTLY OR INDIRECTLY, BY THE ADOPTION AND/OR USE OF THIS DRAYANa THIS INCLUDES, BUT IS NOT RESTRICTED TO ANY INTERRUPTION OF SERVICES, LOSS OF ACTUAL OR ANTICIPATED BUSINESS, INCOME, AND PROFITS, OR CONSEMENTIAL DAMAGES ARISING FROM, OR ASSOCIATED WITH THE USE CC ANY PRODUCT MADE IN ACCORDANCE WITH THIS DRAWING. FURTHERMORE, THIS DRAWING MUST NOT BE ASSUMED TO BE AN EQUIVALENT TO, OR A SUBSTITUTE FOR, ANY GENERAL USAGE OR PROJECT SPECIFIC DESIGN UNLESS ANALYSED AND APPROVAED AS SUCH BY AN INDEPENDANT AND APPROPRIATELY QUALIFIEE PROFESSIONAL ARRANGING FOR ANY SUCH ASSESSMENT IS THE RESPONSIBILITY CC THE CUSTOMER PURCHASING THE PRODUCT SATAN Al THIS DRAWING FROM EVERHARD INDUSTRIES PTY LTD. ISIS THE USERS RESPONSIBILITY TO ENSURE THE APPROPRIATE PRODUCT IS SELECTED tc THAT THE CORRECT SCALE MEN USING A DRAPING IS UTILISED.

    DRAWN

    BJD

    TITLE UANOVA — 80203 — POLYMER TANK

    AWTS TREATMENT SYSTEM 2 x 4000 LITRE TANKS

    100dia INSPECTION OPENINGS

    BACKFILL WITH

    SELECTED FILL

    IN ACCORDANCE

    WITH INSTALLATION

    INSTRUCTIONS

    50 dia VENT

    DATE

    10/9/07

    CONTROL BOX WITH ALARM LIGHT REFER ELECTRICAL INSTRUCTIONS 1201/m BLOWER FITTED

    EMERGENCY STORAGE VOLUME

    CONTACT CHLORINATOR

    BACTERIA MEDIA

    SUBMERSIBLE PUMP - REFER TABLE

    APPROVED FOR MANUFACTURE MATERIAL MASS SCALE

    1:25

    PROD. No

    Refer Table

    405 NEWAN ROAD, CEEBUNG, OLD,

    EVERHARD INDUSTRIES PTY LTD e„, 07 ) 3637 6444 4034

    FAA ( OTT 32652m

    DRAWING NUMBER M — 5815

    REVISION

    6

    DATE

    110915

    Rev 6 110915, PL. New chlorinator fitted. Disclaimer added.

  • TANK INSTALLATION AND PLUMBING

    TO BE IN ACCORDANCE WITH PLUMBING INSTRUCTIONS PROVIDED WITH SYSTEM

    1100 1100 25d1a IRRIGATION LINE

    2100

    PLAN VIEW - TREATMENT SYSTEM THIS INLET PIPE L 300

    100dia RUBBER RING CONNECTOR

    METHOD NOT TO I MIN BE USED UNLESS PIPE IS SUPPOR ED

    SEDIMENTATION CHAMBER

    DISINFECTION & PUMPOUT CHAMBER EFFLUENT APPLICATION/1RRIGATION SYSTEM TO BE AS PER INSTRUCTIONS OR DESIGN PROVIDED WITH EACH INDIVIDUAL SYSTEM.

    INCOMING WASTE FLOW

    100 DIA PVC RUBBER' RING SLIP COUPLING OR PAN COLLAR AERATION CHAMBER

    EXCAVATION LINE 4.3m x 2.2m x 2.20m DEEP

    TREATMENT TANK PRIMARY TANK

    SECTION - TREATMENT SYSTEM 50mm THK SAND BE

    CONTROL BOX WITH ALARM LIGHT REFER ELECTRICAL INSTRUCTIONS

    1000 It EMERGENCY STORAGE CAPACITY PRIOR TO OVERFLOW INTO CLARIFICATION, CONTACT OR IRRIGATION TANK SHOWN HATCHED ABOVE NORMAL OPERATING LEVELS

    0

    LLJ

    APPROVED

    16 NOV 2015

    NSW MINISTRY OF HEALTH

    BACKFILL WITH SELECTED FILL IN ACCORDANCE WITH INSTALLATION INSTRUCTIONS

    CONTACT CHLORINATOR

    BACTERIA MEDIA

    DAVEY 25 SUBMERSIBLE PUMP

    1578

    100dia INSPECTION OPENINGS 1791 50 dia VENT

    PRODUCT CODE No 80206 80206C 80206D

    AMMENDMENT 1

    DRAWN

    BJD

    DATE APPROVED FOR MANUFACTURE

    3/3/2008

    Chlorinator upgraded, Disclaimer added PL 071015

    MATERIAL MASS SCALE PROD. No.

    1 : 25 80206 DETAILS / DESCRIPTION Davey 25 Pump fitted Claytons Blue Diver 30 Pump fitted Davey 42 Pump fitted

    EVERHARD INDUSTRIES PTY LTD ACCEPTS NO LIABILITY OR RESPONSIBILITY TO THE USER OR ANY OTHER PERSON OR ENTITY MATH RESPECT TO ANY LIABUTY, LOSS, DAMAGE OR INJURY CAUSED OR ALLEGED TO BE CAUSED. OTHER DIRECTLY OR INDIRECTLY, BY THE ADOPTICN AND/OR USE Of THIS DRAVANG. THIS INCLUDES, BUT IS NOT RESTRICTED TO, ANY INTERRUPTION OF SERTACES, LOSS OF ACTUAL OR ANDCIPATED BUSINESS, INCOME, AND PROFITS, CR CONSEQUENTIAL DAMAGES ARISING FRCW. OR ASSOCIATED NIT THE USE CF ANY PRODUCT MADE IN ACCORDANCE VITA THIS °RAMC. FURTHERMORE, THIS DRAWING MUST NOT BE ASSUMED TO BE AN EQUIVALENT TO, OR A SUBSTITUTE FOR, ANY GENERAL USAGE OR PROJECT SPECIFIC DESIGN UNLESS ANALYSED AND APPROVAED AS SUCH IT AN INDEPENDANT AND APPROPRIATELY QUALIFIED PROFESSIONAL ARRANGING FOR ANY SUCH ASSESSMENT IS THE RESPONSEILITY CF THE CUSTOMER PURCHASING THE PRODUCT SHOliN 64 THIS DRAWING FROM EVERHARD INDUSTRIES PTY LTD. 10 15 THE USERS RESPONSIBILITY TO ENSURE THE APPROPRIATE PROOUCT IS SELECTED & THAT THE CORRECT SCALE MIEN USK A RAMC IS unusEo.

    TITLE

    AOLJANOVA POLYMER TANK SYSTEM 2 x 300011 TANKS — SOUTH CONFIGURATION

    WITH 450mm NOMINAL RISERS DRAWING

    NUMBER

    M — 5942

    EVERHARD INDUSTRIES PTY LTD 41m55 N(EVAI00AN) 3R603 AD,64GE4REBUNG OLD, 4034

    FAX ( 07(3265 2111

    REVISION DATE

    2 071015

  • 25dia IRRIGATION LINE 1100 2100 1100

    PRIMARY TANK TREATMENT TANK

    TANK INSTALLATION AND PLUMBING TO BE IN ACCORDANCE WITH PLUMBING INSTRUCTIONS PROVIDED WITH SYSTEM

    THIS INLET PIPE 300

    METHOD NOT TO r*MIN

    BE USED UNLESS

    PIPE IS SUPPORTED

    N INCOMING WASTE FLOW

    100 DIA PVC RUBBER RING SLIP COUPLING

    OR PAN COLLAR

    100dia RUBBER

    RING CONNECTOR

    PLAN VIEW - TREATMENT SYSTEM

    SEDIMENTATION CHAMBER

    DISINFECTION & PUMPOUT CHAMBER EFFLUENT APPLICATION/IRRIGATION SYSTEM

    TO BE AS PER INSTRUCTIONS OR DESIGN

    PROVIDED WITH EACH INDIVIDUAL SYSTEM.

    AERATION CHAMBER

    EXCAVATION LINE

    4.3m x 2.2m x 2.20m DEEP AP

    PR

    OV

    ED

    CONTACT CHLORINATOR BACTERIA I\IEDIA

    DAVEY 25 SUBMERSIBLE PUMP

    BACKFILL WITH

    SELECTED FILL

    IN ACCORDANCE

    WITH INSTALLATION

    INSTRUCTIONS

    SECTION - TREATMENT SYSTEM 50mm THK SAND BE

    1791 50 dia VENT

    PL 071015 Upgraded Chlorinator fitted, disclaimer added AMENDMENT 4

    100dia INSPECTION OPENINGS CONTROL BOX WITH ALARM LIGHT REFER ELECTRICAL INSTRUCTIONS

    1000 It EMERGENCY STORAGE CAPACITY PRIOR TO OVERFLOW INTO CLARIFICATION, CONTACT OR IRRIGATION TANK SHOWN HATCHED ABOVE NORMAL OPERATING LEVELS

    1578

    APROVED FOR MANUFACTURE

    2/7/2005

    EVERHARD INDUSTRIES PTY LTD ACCEPTS NO LIABILITY OR RESPONSIBILITY TO THE USER OR ANY OTHER PERSON CR ENTITY WITH RESPECT TO ANY LIABILITY, LOSS, DAMAGE OR INJURY CAUSED OR ALLEGED TO BE CAUSED, EITHER DIRECTLY OR INDIRECTLY, BY THE ADOPTION AND/OR USE OF THIS DRAWING. THIS INCLUDES, BUT IS NOT RESTRICTED TO, ANY INTERRUPTION OF SENCES, LOSS OF ACTUAL OR ANTICIPATED BUSINESS, INCOME, AND PROFITS, OR CONSEQUENTIAL DAMAGES ARISING FROM, OR ASSOCIATED WITH THE USE OF ANY PRCOUCT MADE IN ACCORDANCE YIN THIS PRAYING. FURTHERMORE, THIS DRAWING MUST NOT BE ASSUMED TO BE AN EQUIVALENT TO, OR A SUBSTITUTE FOR, ANY GENERAL USAGE OR PROJECT SPECIFIC DESIGN UNLESS ANALYSED AND APPROVAED AS SUCH BY AN INDEPENDANT ANO APPROPRIATELY OUALIFIED PROFESSIONAL. oRRANGING FOR ANY SUCH ASSESSMENT IS THE RESPONSIBILITY OF THE CUSTOMER PURCHASING THE PRODUCT SHOWN IN THIS DRAWING FROM BERHARD INDUSTRIES PTY LTD. IT IS THE USERS RESPONSIBILITY TO ENSURE THE APPROPRIATE PROOUCT IS SELECTED & THAT THE CORRECT SCALE OMEN USING A DRAWING IS UTILISED.

    DRAWN

    DATE

    BJD

    29/8/2002 TITLE

    AQUANOVA POLYMER

    'SOUTH' TANK SYSTEM WITH RISERS

    PRODUCT CODE No. DETAILS / DESCRIPTION 80200

    Davey 25 Pump fitted 80200C

    Claytons Blue Diver 30 Pump fitted 802000

    Davey 42 Pump fitted

    MATERIAL MASS

    SCALE

    :25

    PROD. No

    80200

    EVERHARD INDUSTRIES PTY LTD 405 14EMIAN ROAD, CREASING, OLD, 4034 PH 07 ) 3637 6444 FAX : ( 07 ) 3265 2111

    DRAWING NUMBER M — .3877

    REVISION

    4

    DATE

    071015

  • 25mm dia URVC SLUDGE RETURN LINE

    APPROVED FOR MANUFACTURE MATERIAL

    C's.1

    AP

    PR

    OV

    ED

    Co

    NS

    W M

    INIS

    TR

    Y O

    F H

    EALT

    H

    1100

    25dla IRRIGATION LINE--

    410*• . /0,

    • alort. t.

    PRIMARY TANK TREATMENT TANK

    PLAN VIEW - TREATMENT SYSTEM

    ( fr,vo 4040,

    410 v.` • II +.10A• •

    w

    100dla RUBBER RING JOINT PIPE

    THIS INLET PIPE METHOD NOT TO k 300 BE USED UNLESS I MIN PIPE IS SUPPORTED

    INCOMING WASTE FLOW

    100 DIA PVC RUBBER RING JOINT

    MANHOLE COVER

    e

    CONTROL BOX WITH IN-HOUSE ALARM REFER ELECTRICAL INSTRUCTIONS

    1660

    1 725 o — I 1125 I.Mom

    / / /

    't . / .

    1 : Alia - = ii. al -7 IV / 1510 ' NM

    i Ili •-• 1,

    BACKFILL WITH ... 1C85 k: SELECTED FILL FILL IN ACCORDANCE WITH INSTALLATION

    INSTRUCTIONS

    ..... OP. OW VIM

    ...

    ... W. IS.

    1610 v ..10.

    160

    de.

    ....

    L ti 0 \O

    50mm THK SAND BED -----------f- 1735 930

    TANK INSTALLATION AND PLUMBING TO BE IN ACCORDANCE WITH PLUMBING INSTRUCTIONS PROVIDED WITH SYSTEM,

    SECTION - TREATMENT SYSTEM

    100dla INSPECTION OPENINGS 1785

    -- SEDIMENTATION CHAMBER

    — DISINFECTION & PUMFOUT CHAMBER EFFLUENT APPL ICAT ION/I RRIGATION SYSTEM TO BE AS PER INSTRUCTIONS OR DESIGN PROVIDED WITH EACH INDIVIDUAL SYSTEM,

    ----- AERATION CHAMBER

    EXCAVATION LINE 4,3m x 2,2m x 2,1m DEEP

    50 dla VENT

    -- TANK CASE REFER DWG M-1134

    SECURE BEAM TO TANK CASE WITH 21110 BOLTS EACH END THROUGH12rnrn DRILLED HOLES IN TANK CASE WALL

    CONTACT CHLORINATOR

    BACTERIA MEDIA

    SUBMERSIBLE PUMP

    Rev 5 10/9/15 PL, Uparoded Chlorinator fitted. Disclaimer added.

    PRODUCT CODE No. 10100 10100C 101000

    DETAILS / DESCRIPTION Davey 25 Pump fitted Cloytoris Blue Diver 30 Pump fitted Dovey 42 Pump fitted

    DURHAM INDuSTRES FIR LTD ACCEPTS NO LIAEILITY SO REECH9BILITY TO THE LEER CR OHS On-ER FERsoN 03 ENITTy 'NTH RESfECT TO ANY LIAIIIJTI. LOSS. DAMAGE 00 rouRy CA.48) CR ALLEGF_D TO SE CAUSED, EnHER DIRECTLY OR INDIRECTLY, BY 11-E ADOPTION Au)/CR uSE OF THIS DRAWN:, THIS INCLUDES, BJT IS Nol REsrlocrED 101, ANY ISTERRUPTiat CF SERVICES, LOSS OF ACTUAL OR ANTTEIRATED BJRNESS, INCOME, MO PUTTS, CR CONSECUENTIAL OA1LAGES 45I915 FROM, 03 ASSOCIATES 6114 THE UE GE ANI FRODuCT mnE H ACCOMANCE ICH THIS CF,PAING FURTHERNORE, THIS DRAydNG ;MST HOT if ASSUME° TO BE AN EiNVAIENT TO, OR A StNISTITUTE FOR, ANY GENERAL USAGE GR 1460:Ect S'oEcIRC CESIGN u,LESS AnALYSED AND APPROvAEO AS SUCH BY AN INLEPENDANT AND APFROKIATELY wino PRcFEsSioNaL crialAudu0 FOR ANY SUCH ASESSMOIT IS of REsVISIORITY OF THE cusTWER PuRCHASTNG 11-E PRCOUCT SHOO IN THIS 00644150 NCH BERHARD nousouEs PTY LTD. IT IS DI usEITS RESPONSIBILITY TO 111StRE THE APPRCPRATE PR000C1 IS 9ELECTED & 1461 THE CORRECT SCALE lif-EN uSINC A CRANING IS C111.15.83.

    EVERHARD INDUSTRIES PTY LID DR AVANG NUMBER M — 5816

    PROD. No

    1 01 00 405 NEWAN EOM, CEEIRIG, CID, ,D34 FR I 571 3637 1414 FAX. ( 07 I 3265 2111

    REVISION

    5

    DRAWN

    BJD

    DATE

    10-5-2007

    ASS

    T IT L E

    AQUANOVA CONCRETE TANK AWTS TREATMENT SYSTEM 2 x 3000 LT TANKS — EP10

    SCALE

    1:25

    DATE

    10/9/15

  • TREATMENT TANK INSTALLATION 25mm DIA IRRIGATION LINE TANK AND PLUMBING TO BE IN ACCORDANCE WITH

    PRIMARY PROVIDED WITH SYSTEM. PLUMBING INSTRUCTIONS

    ----.

    _ 300 MIN THIS INLET PIPE METHOD NOT TO BE USED UNLESS PIPE IS SUPPORTED I

    I

    I

    \ I \ \)

    tips. \ 7%le.r. 100 1111V•

    aiiitta VA' , leimpuwilpiy, 5.,

    fee. r ',- 11111.0 / I • t -

    1

    ea,' ...-

    0 eAlFe 4 iit,

    ' 410.4..al.

    --- NO 11P.,,,r,

    N ' W ---

    EFFLUENT APPLICATIOWIRRIGATION

    IMENTATION CHAMBER

    SYSTEM TO BE AS PER INSTRUCTIONS OR DESIGN PROVIDED WITH EACH INDIVIDUAL SYSTEM.

    ___ ___ ' i

    '

    EXCAVATION LINE ---- 5.0m x 2,5m x 2.22m DEEP

    / 100mm DIA uPVC RUBBER RING JOINT

    INCOMING WASTE FLOW - -

    --

    el-

    \

    _

    1

    _ i

    -

    100mm RING

    \

    DIA RUBBER JOINT PIPE

    \alltlimilt Ie.

    .04 Ip*of 11k Ili 114.011

    III.

    ' r

    40410741(

    ) 4,1) 0 411

    - 40:40K

    .... - • 0,44

    .,,„ 00

    1110 ------__

    DISINFECTION & PUMPOUT CHAMBER

    - _

    1\'\

    - 1250 .

    _

    2500 -- _ _ __------

    1250 . '

    ----AERATION CHAMBER

    RISERS UPTO A VAHIMUM HEIGHT . OF 900mm CAN BE ADDED TO

    THE TANK CASE TO INCREASE ELECTRICAL CONTROL BOX DEPTH TO INVERT WHERE NECESSARY 970

    25mm DIA uPVC SLUDGE RETURN LINE

    WITH ALARM LIGHT

    ___ 50mm DIA VENT

    _

    - ..- BACKFILL TO RIM OF TANK WITH SELECT BACKFILL ONLY

    . ..,,, • FO

    / . ,..., /

    . / \ ,,, \ .., =

    T\\ \\,, - -

    --/ , 1550 . 1655 / < -

    . 1650 an

    /7 , \ ---- 1000 It EMERGENCY STORAGE a L.LJ

    I 1535 CAPACITY PRIOR TO OVERFLOW, LC) = -11300. -- INTO CLARIFICATION, CONTAC ,,,/./

    AP

    PR

    OV

    E

    16 N

    OV

    201

    !

    NSW

    MI N

    IST

    RY O

    F I .

    -

    • r,1400 // OR IRRIGATION TANK SHOWN \

    \ 1265 • .

    ill 4; lei 1340 I 1320

    c

    /

    / / \

    . •

    _

    4

    -r-_

    i! U2'"=-

    rm. • ---- /.',

    N cy

    /

    ./‹. / \

    . ,

    .:s. .

    dlo• ---",---„,,,_. -.*

    //------------ CONTACT CHLORINATOR

    ,___..

    / 945 945 .,. ia. +op BACTERIA MEDIA / / , 300

    eop.

    ..... rm.

    ....

    , \

    SUBMERSIBLE PUMP - REFER TAB \

    / _ '

    4 . . • a • , . 4 \

    \ ' V// : // . V// . V/. / . \/// . \///. s // / , \ // h q /// ' /7; - 50mm MIN THK SAND BED

    f ,

    / , /// , ' . / /// • \ / -

    AMVENDLtENT 5 Chlorinator updated, Disclaimer added 071015 PL

    PRODUCT CODE No. DETAILS / DESCRIPTION EVERHARD 10,1SPIES PT, LID ACCEPTS NO ABILITY CR RESPCIMBLITY TO THE USER OR ANY OTHER PERSON CR DOM MTH RESzECT TO ANY LIABILRY, LOSS, DAWAGE CP. ItthRY CAUSED OR ALLEGED TO BE comm.OR EITHER DIRECTLY CR INDIRECTLY. BY TIE ADOPITh AND/OR USE CF TRIO CLRA'ANG. THIS IMUCES. Eul IS NOT RESTRICTED TO.

    AM

    BJD DATE

    17 - 3 - 2010 AP?R0',ED FOR MANUFACTURE MATERIAL MASS SCALE

    i : 25 FRO/ No

    10114 DAVEY 25 PUMP FITTED 10114C CLAYTECH BLUE DIVER 30 PUMP FITTED

    ANY INTERRuPTICII OF SERACES. LOSS CF ACTUAL OR ANTI:PATO BUSINESS, 140011E, AND PAWS. OR CONSEQUENTIk WAGES ARISNO FRO% CR ASSOCIATED ROTH11-E UDE OF ANY PRODUCT WADE IN Accgioma 111TH THIS DRAIAING. FURTIERIMNE, THIS CRAtING HOST HOT RE ASMED TO BE AN EOJIVALEAT TO. OR A SUBSTITUTE FCR, ART GENERAL USAGE CR PiOJECT SPECIE': 06I21 UNLESS ANALYSED MD APPROVAED AS SUCH BY AN KAFFE\DANT AND A;PRO7P.IATELY CUALFIED

    TITLE AQUANOVA - 10114 - CONCRETE

    405 NEWNAN ROAD, CEEOUNG, LEO, 4034 EVERHARD INDUSTRIES PTY LID PH : I 07) ..637 6444

    FAX : ( 07 1 3765 7151

    10114D DAVEY 42 PUMP FITTED PRCESSIMAL eRRANING RR ANY SJCH Asssmid- IS THE RESPONSIBILITY CF TIE CUSTOKR FURCHASKG TIE FROCUCT SHOWN N IRIS DRA'ANG ERIN EOM ItiNSTRES PIT LID. IT IS 111E USERS RESPasSISILITY TO ERSuuE TIE APRoPaim Pima IS SELECTED A THAT THE CCRRECT SCALE WHS USES A GR1110 FS imuSED.

    TREATMENT SYSTEM - 2 x 3000It CASES

    DRAWING NUMBER NA p -

    3571 REVISION

    5

    DATE

    07101 5