76
Even the most complex building can be simply managed to KNX standard. WELL-CONTACT PLUS

Even the most complex building can be simply managed to ...€¦ · Even the most complex building can be simply managed to KNX standard. WELL-CONTACT PLUS. 1 The system to control

  • Upload
    others

  • View
    8

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Even the most complex building can be simply managed to ...€¦ · Even the most complex building can be simply managed to KNX standard. WELL-CONTACT PLUS. 1 The system to control

Even the most complex building can be simply managed to KNX standard.

WELL-CONTACT PLUS

Page 2: Even the most complex building can be simply managed to ...€¦ · Even the most complex building can be simply managed to KNX standard. WELL-CONTACT PLUS. 1 The system to control
Page 3: Even the most complex building can be simply managed to ...€¦ · Even the most complex building can be simply managed to KNX standard. WELL-CONTACT PLUS. 1 The system to control

1

The system to control automation, entry, HVAC and lighting for an entire building by means of a single system developed to the KNX standard. The Vimar range has evolved with hardware that has been redesigned and enriched with new functions, new flush mounting products and DIN rail products as well as a software suite dedicated to system monitoring.

Introduces the new range of Well-contact Plus to standard.

Page 4: Even the most complex building can be simply managed to ...€¦ · Even the most complex building can be simply managed to KNX standard. WELL-CONTACT PLUS. 1 The system to control

2

Page 5: Even the most complex building can be simply managed to ...€¦ · Even the most complex building can be simply managed to KNX standard. WELL-CONTACT PLUS. 1 The system to control

With Well-contact Plus Vimar has evolved the KNX range with hardware that has been redesigned and enriched with new functions, new flush mounting and DIN rail products, as well as a software suite dedicated to system supervision. Simplified installation and configuration with ETS software and dedicated Vimar software; control and supervision through the broad range of solutions.

Well-contact Plus: controls automation, access, climate and lighting with a single system developed to the KNX standard.

3

Page 6: Even the most complex building can be simply managed to ...€¦ · Even the most complex building can be simply managed to KNX standard. WELL-CONTACT PLUS. 1 The system to control

BASIC TOP CLIENT

Manages a hotel structure with up to 50 rooms from a single station. 5 password levels, planner for checking arrivals and departures.

For large hotel structures, with a potentially limitless number of rooms and stations. Application with 7 password levels and planner for supervising arrivals and departures.

Basic and Top application licence. Enables managing the system from a number of stations.

4

Page 7: Even the most complex building can be simply managed to ...€¦ · Even the most complex building can be simply managed to KNX standard. WELL-CONTACT PLUS. 1 The system to control

Well-contact Suite: 5 versions for a custom system.

CLIENT OFFICE

Office application licence. Provides access to the program from a number of stations.

For business and commercial offices and structures. Applica-tion with 7 password levels that enable managing the functions of a potentially limitless number of rooms from one station.

OFFICE

5

Page 8: Even the most complex building can be simply managed to ...€¦ · Even the most complex building can be simply managed to KNX standard. WELL-CONTACT PLUS. 1 The system to control

A sophisticated and modern de-sign frames both the touch screen with 4+4 modules and 4.3” dis-play and the one with 3 mod-ules. Devices with independent push buttons and presence sen-sors enable managing scenes, lights and roller shutters. The supervision can cover a whole area or a single room or office.

control and supervision

The world of building control speaks KNX: approved as an international, European and Chinese standard, it has millions of successful installations and is open to the future. The KNX mark guarantees the interoperability of the products independently of the constructor and the particular application. Lighting, Venetian blinds and roller shutters, safety systems, energy management, HVAC systems, monitoring systems, remote control, accounting, audio/video control and household

appliances: it can all be managed, controlled, monitored and signalled with a single system, without any additional control panels. Connecting all the devices with a single Bus considerably reduces the time for design, installation and, thanks to the ETS software, configuration too. With the advantage of exceptional flexibility and adaptability of the system to future developments through a simple connection of the new components and applications to the existing Bus.

Standard: the most secure connection to coordinate all the functions.

6

Page 9: Even the most complex building can be simply managed to ...€¦ · Even the most complex building can be simply managed to KNX standard. WELL-CONTACT PLUS. 1 The system to control

Well-contact Plus is aesthetically coordinated with the three Vimar residen-tial series: Eikon, innovative design and premium materials, Idea a classic with the greatest freedom of choice and Plana an element of pure essentials. Three icons of Italian style characterized by an incomparable depth of range.

Temperature control for each room is managed with ther-mostats developed to the KNX standard. Savings are assured thanks to the supervision of the Well-contact Suite software, which enables control with-out having to enter every room.

The transponder card read-ers permit only the allowed accesses. The reader with a vertical pocket, positioned in the room, activates users and scenes, which can also be man-aged with the touch screen that elegantly replaces the buttons.

climate control access control

Different functions with a coordinated look: the automation of the building is complete.

7

Page 10: Even the most complex building can be simply managed to ...€¦ · Even the most complex building can be simply managed to KNX standard. WELL-CONTACT PLUS. 1 The system to control

Reader with vertical pocket.To activate temperature control and the lights simply insert the card into the pocket of the transponder reader.

Cord-operated button.From the bathroom as from any other room, it transmits the call for help to the reception for prompt assistance.

Transponder reader.Simply bring the card near to open the electrical lock and turn on the courtesy lights. The room will give you its welcome with a comfortable climate.

Thermostat.User-friendly and easy to read, it displays, manages and modifies the ambient temperature.

DIN rail appliances. Extremely reliable technologies that manage all the functions to create atmospheres with the utmost comfort.

Controls.Behind what at first glance seems to be an ordinary single button, there are up to 4 different keys with related functions that can be activated.

8

Page 11: Even the most complex building can be simply managed to ...€¦ · Even the most complex building can be simply managed to KNX standard. WELL-CONTACT PLUS. 1 The system to control

This card provides access to the pre-mium services of both the hotel and

the structures that have arrangements with the hotel (spa, gym, solarium,

garage).

Mifare® RF-ID card

Hotel management: effective and optimized, it assures an impeccable service.

9

Page 12: Even the most complex building can be simply managed to ...€¦ · Even the most complex building can be simply managed to KNX standard. WELL-CONTACT PLUS. 1 The system to control

3-module touch screen.Simply touch the display to control the lights and temperature of a single room without getting up from your desk.

Touch screen with 4.3” display.For total and immediate supervision of even the largest common areas.

Controls.Multifunctional, they assure managing various controls from a single device.

Transponder reader.Allows access to the premises only by cleared personnel: simply move the transponder card near to the reader and identification is instantaneous.

Thermostat.To regulate and always keep the temperature under control from one office to another.

10

Page 13: Even the most complex building can be simply managed to ...€¦ · Even the most complex building can be simply managed to KNX standard. WELL-CONTACT PLUS. 1 The system to control

Office management: secure and intelligent, it allows constant communication amongall the devices.

11

Page 14: Even the most complex building can be simply managed to ...€¦ · Even the most complex building can be simply managed to KNX standard. WELL-CONTACT PLUS. 1 The system to control

12

Description Code

4,3” color touch screenColor touch screen, 4.3 in, for the control, Well-contact Plus, with built-in mounting frame for installation in 8-module mounting box

Monochrome touch screenMonochrome touch screen, for the room control, Well-contact Plus - 3 modules

Device with 4-independent push buttonsControl device with four independent push buttons, KNX standard, visible in darkness, to be completed with half-buttons - 2 modules

Presence detectorPassive infrared presence detector, KNX standard - 2 modules

Guideline

Description Code

Transponder card readerTransponder card reader for installation outside rooms, KNX standard, 2 NO 4 A 24 V~ relay outputs, 2 inputs, power sup-ply 12-24 V~ 50-60 Hz and 12-24 V d.c. (SELV) - 3 modules.Supplied without transponder card

Transponder card reader with pocketTransponder card reader with vertical pocket for installation inside rooms, KNX standard, 2 NO 4 A 24 V~ relay outputs, 2 inputs, supplementary power supply 12-24 V~ 50-60 Hz and 12-24 V d.c. (SELV) - 3 modules

Lettore/programmatoredi carte a transponderTransponder card reader/programmer, in table mounting box. To complete with cover plate

Transponder cardProgrammable transponder card for reader for inside or outside the room, back side customizable

Control and supervision

Access control

20457grey

20457.Bwhite

20457.NNext

16927grey

16927.Bwhite

14457white

14457.SLSilver

20848grey

20848.Bwhite

20848.NNext

14848white

14848.SLSilver

14849white

14849.SLSilver

20849grey

20849.Bwhite

20849.NNext

16849grey

16849.Bwhite

16840grey

14840white

16840.Bwhite

20850grey

20850.Bwhite

20850.NNext

16850grey

16850.Bwhite

14850white

14850.SLSilver

20453grey

20453.Bwhite

20453.NNext

14453white

14453.SLSilver

16923grey

16923.Bwhite

20450grey

20450.Bwhite

20450.NNext

16920grey

16920.Bwhite

14450white

14450.SLSilver

01598

Description Code

Electronic thermostatThermostat for ambient temperature control (heating and air-conditioning), KNX standard, NO 4 A 24 V~ relay output, 1 input - 2 modules

Temperature control

20451grey

20451.Bwhite

20451.NNext

16921grey

16921.Bwhite

14451white

14451.SLSilver

20840grey

Page 15: Even the most complex building can be simply managed to ...€¦ · Even the most complex building can be simply managed to KNX standard. WELL-CONTACT PLUS. 1 The system to control

13

System devicesDescription CodeDevices for DIN (60715 TH35) rail

Supply unit with Bus 30 V d.c. outputPower supply with Bus 30 V d.c. 320 mA output, supply voltage 230 V~ 50-60 Hz, with decoupling coil, KNX standard, occupies 4 17,5 mm modules

Supply unit with Bus 30 V d.c. auxiliary outputPower supply with Bus 30 V d.c. 640 mA output, 30 V d.c auxiliary output, supply voltage 230 V~ 50-60 Hz, with decoupling coil, KNX standard, occupies 4 17,5 mm modules

Line couplerLine coupler, KNX standard, occupies 3 17,5 mm modules

Description CodeDevices for DIN (60715 TH35) rail

B-type USB interfaceUSB interface, KNX B-type, occupies 2 17,5 mm modules

Safety transformerSafety transformer, 230/12-24 V~ (SELV) 24 VA, for continous duty, occupies 3 17,5 mm modules, RAL 7035 grey

LSZH cable2x2x0,8 mm cable, LSZH halogen-free, green- 100 m

01540

16887

01500

01504

01501

01890

Software and interfaceDescription Code

Well-contact SuiteWell-contact Suite software for Well-contact Plus devices management, complete with CD and hardware key

EasyTool software and touch screen configuratorEasyTool software and Well-contact Plus touch screen configurator with USB interface

01590WCS Basic

01591WCS Top

01592WCS Client

01595WCS management

WCS Gestionali WCS Office Client WCS Office WCS Client WCS Top WCS BasicWCS Gestionali WCS Office Client WCS Office WCS Client WCS Top WCS BasicWCS Gestionali WCS Office Client WCS Office WCS Client WCS Top WCS BasicWCS Gestionali WCS Office Client WCS Office WCS Client WCS Top WCS Basic 01593WCS Office

01594WCS Office Client

WCS Gestionali WCS Office Client WCS Office WCS Client WCS Top WCS BasicWCS Gestionali WCS Office Client WCS Office WCS Client WCS Top WCS Basic

01998.U

Automation devicesDescription CodeDevices for DIN (60715 TH35) rail

4- digital inputs device4-channel digital input device, programmable for NO, NC and 120-230 V~ contacts, KNX standard, occupies 2 17,5 mm modules

4 NO 16 A 250 V~ relay outputs actuatorActuator with 4 NO 16 A 250 V~ relay outputs, KNX standard, occupies 4 17,5 mm modules

Input/output deviceInput/output device, 4 NO 16 A 250 V~ relay outputs, 4 inputs for NO contacts, KNX standard, occupies 4 17,5 mm modules

2 roller shutters actuatorActuator for 2 roller shutters, 16 A 250 V~ relay outputs, KNX standard, occupies 4 17,5 mm modules

Description CodeDevices for DIN (60715 TH35) rail

DimmerDimmer, 2 inputs for 01530, 2 NO 16 A 250 V~ relay outputs, 2 1-10 V outputs, KNX standard, occupies 4 17,5 mm modules

Light sensorLight sensor for dimmer 01528, KNX standard, ceiling installation

4-channel interfaceInterface with 4 input or output programmable channels for LEDs, KNX standard

Dimmer 230 V~ 50-60 HzDimmer 230 V~ 50-60 Hz for 2x300 W incandescent lamps, 2x300 VA ferromagnetic transformers, 2x300 VA electronic transformers, KNX standard, occupies 4 17,5 mm modules

01524 01526

01528

01523

01510

0152201515

01530

Page 16: Even the most complex building can be simply managed to ...€¦ · Even the most complex building can be simply managed to KNX standard. WELL-CONTACT PLUS. 1 The system to control

14

Automation for buildingsGeneral characteristics

(courtesy lights, etc.), room service calls, alarms (ceiling pull, etc.) and energy savings (turning off the heating/air-conditioning after detecting an open window, etc.).

The range of products is completed by a DIN rail input/output device able to manage 4 inputs and 4 outputs, all freely programmable, that can be associated with additional services such as, for example, controlled sockets, room indicators, alarms and scenes that enable the various users depending on who enters the room (guest, service personnel, maintenance engineer, etc.); everything will obviously always be supervised by reception that, thanks to the Well-contact Suite software, entirely developed by Vimar, will have control over all the events linked to the guest’s “history” for the entire duration of her stay.

The functions that each device must perform are programmed with the ETS software; in other words, a project is created in which each room is composed of a certain number of components, each of which is assigned operational parameters.

It will therefore be possible to choose, for instance, whether a relay must work in one-position stable, two-position stable, NC or NO mode or the type of thermostat temperature control (proportional integral, ON/OFF, etc.) or set up an input to recognize signal fronts, cyclical repetitions, etc..

ETS also enables Well-contact Plus devices to interact with other KNX appliances not supplied by Vimar, not only to make the system suitable for the widest range of applications, but also to be able to supplement it with existing devices (renovations).

The main competitive characteristics of the Well-contact Plus system can be summarized as follows: •nocentralized intelligent room module is necessary; • all the functions and “intelligence” of the system are

distributed over the various appliances; • the flushmounting devices that must be installed in the

room are equipped with free inputs and relay outputs that reduce the need for additional terminals;

• thesystem isextremely flexible thanks to the modularity of the range and its potential for easy, low-cost expansion to meet future needs;

• extremely simple, flexible system management software that also allows interfacing with the most widely used administrative software.

Field of applicationThe Well-contact Plus system, in the hotel and tertiary sector, enables making centralized management systems that allow integrating and supervising many functions and services efficiently guaranteeing simplicity of use by the personnel in charge.

Hotels and more in general hospitality facilities require systems for optimized and effective management of their services that simplify daily operation and, as far as possible, reduce running costs, optimizing energy savings and guaranteeing a high level of comfort for their guests.

The devices of the Well-contact Plus system, developed to KNX standard technology and aesthetically coordinated with the series of Eikon, Idea and Plana, offer technical solutions featuring outstanding efficiency, perfectly meeting all the most varied installation requirements and the constraints imposed by the different structures such as hotels, offices, shopping malls and the advanced tertiary sector in general.

Main characteristicsBeing based completely on KNX technology, each device is able to perform the required functions directly; each component has resident intelligence enabling direct dialogue with all the devices in the network. The KNX standard was developed to create decentralized systems where the interchange of signals and commands takes place exclusively at the level of operational devices: that is each component is able to process the data independently and transmit and/or detect signals directly on the system Bus. In short, therefore, each structure and each application can assign the priorities that it deems necessary without having to accept “take it or leave it” solutions and in any case without jeopardizing the possibility of a future implementation to extend the system’s functions.

Thanks to Well-contact Plus, each hospitality facility can select the most suitable solution, “customizing” it and ensuring the flexibility that only the common European protocol (KNX) can provide in terms of interoperability of devices and secure installation.

The single devices such as the external transponder reader, the reader with a pocket and the thermostat, besides the typical functions of card recognition and electrical lock opening, service activation and temperature control respectively, have freely programmable inputs and outputs that make the system really flexible. These inputs/outputs can be used to control sockets

Page 17: Even the most complex building can be simply managed to ...€¦ · Even the most complex building can be simply managed to KNX standard. WELL-CONTACT PLUS. 1 The system to control

15

General characteristics

644

32

1

Bbc

LC

644

32

1 LC64

43

21 LC

644

32

1 LC64

43

21 LC

644

32

1 LC

...128

LC

644

32

1

Bbc

LC

644

32

1 LC64

43

21 LC

644

32

1 LC64

43

21 LC

644

32

1

...128

LC

644

32

1

Bbc

LC

644

32

1 LC64

43

21 LC

644

32

1 LC64

43

21 LC

644

32

1 LC

...128

LC

644

32

1

Bbc

LC

644

32

1 LC64

43

21 LC

644

32

1 LC64

43

21 LC

644

32

1

...128

LC

644

32

1

Bbc

LC

644

32

1 LC64

43

21 LC

644

32

1 LC64

43

21 LC

644

32

1 LC

...128

LC

644

32

1

Bbc

LC

644

32

1 LC64

43

21 LC

644

32

1 LC64

43

21 LC

644

32

1

...128

LC

644

32

1

Bbc

LC

644

32

1 LC64

43

21 LC

644

32

1 LC64

43

21 LC

644

32

1 LC

...128

LC

644

32

1

Bbc

LC

644

32

1 LC64

43

21 LC

644

32

1 LC64

43

21 LC

644

32

1

...128

LC

644

32

1

Bbc

LC

644

32

1 LC64

43

21 LC

644

32

1 LC64

43

21 LC

644

32

1 LC

...128

LC

644

32

1

Bbc

LC

644

32

1 LC64

43

21 LC

644

32

1 LC64

43

21 LC

644

32

1

...128

LC

644

32

1

Bbc

LC

644

32

1 LC64

43

21 LC

644

32

1 LC64

43

21 LC

644

32

1 LC

...128

LC

644

32

1

Bbc

LC

644

32

1 LC64

43

21 LC

644

32

1 LC64

43

21 LC

644

32

1

...128

LC

644

32

1

Bbc

LC

644

32

1 LC64

43

21 LC

644

32

1 LC64

43

21 LC

644

32

1 LC

...128

LC

644

32

1

Bbc

LC

644

32

1 LC64

43

21 LC

644

32

1 LC64

43

21 LC

644

32

1

...128

LC

644

32

1

Bbc

LC

644

32

1 LC64

43

21 LC

644

32

1 LC64

43

21 LC

644

32

1 LC

...128

LC

644

32

1

Bbc

LC

644

32

1 LC64

43

21 LC

644

32

1 LC64

43

21 LC

644

32

1

...255

LC

0

1

2

3

4

15

0

1

2

33

4

15

0

1

2

3

4

15

0

1

2

3

4

15

0

1

2

3

4

15

0

1

2

3

4

15

0

1

2

3

4

15

0

1

2

3

4

15

12 3

4 5 6 7

15

· up to 64 KNX devices that rising to 255

with additional line couplers

· max distance between two devices in the

same line: 700 m

· max distance between power supply

and device: 350 m Bd backbone line

LC

Bbc

1 64

Field coupler (15 max)

Line coupler (15 max)

KNX devices (64 max)

· up to 15 field couplers defining 15 fie

lds.

· max backbone lin

e length: 1000 m

To other systems

Mai

n l

ine

· up to 15 field coupler defining 15 fields.· max main line length: 1000 m

Well-contact Plus system general diagram

System configuration

Up to three couplers can be connected to each line as repeaters, each one of which manages a segment of up to 64 devices with their power supplies for a maximum of 255 devices. The Bus line can be connected in different configurations (star, tree, etc.); the maximum length in any case must not exceed 1000 m.

Lines can be connected together with the 01504 couplers; it is possible to connect up to 15 lines on a single backbone, which is itself simply a line formed by all the couplers and the devices. This new element is called a field or area; the system can manage up to 15 fields and this represents the maximum expansion of the system.

System architectureThe Well-contact Plus system uses a twisted pair cable as the means of transmission; using the Bus line not only simplifies installation/maintenance, but also ensures a high level of immunity from interference. Information is exchanged between the devices in “telegrams” composed of a set of bits whose combinations encode the transmitted information.

For the purposes of the application functions, the most important information transmitted by each device is the following: •therecipientaddressfieldindicatingthedevicestoreceivethe

message; •the field containing the information related to the actual

function that the device must perform; •thesender’saddress indicating thedevice thathassent the

message.

Each device has a specific “physical” address that identifies it uniquely in the system and therefore there can be no identical physical addresses. As regards the recipient address, under normal operational conditions, this is always a group address; the group addresses make “logical wiring” among different components and it is therefore possible to establish functional correlations (even very complex ones) among the various devices.

Modifying the group addresses with the special ETS configuration software changes the functions of the devices (for instance associations between inputs and outputs) without making any changes to the system wiring. The basic component of the system is the line segment; this is also the starting point for expanding the system up to the maximum possible configuration in terms of devices and shared functions. Each line segment can be composed of up to 64 devices (readers, thermostats, I/O devices, etc.) and needs one or two power supplies depending on the number of components; this is because each device powered at 24 V d.c. has limits on its current absorption (10 mA). If two power supplies are used, they must be set apart at a distance of no less than 200 m. The maximum distance between a device and the power unit on the same line must not exceed 350 m.The maximum distance between two devices on the same line must not exceed 700 m.

Tree Topology Star Topology Mixed Topology

Page 18: Even the most complex building can be simply managed to ...€¦ · Even the most complex building can be simply managed to KNX standard. WELL-CONTACT PLUS. 1 The system to control

16

Automation for buildingsGeneral characteristics

Example of a hospitality facility: connection diagram

FLOOR 1

KNX Bus

12-24 V~

230 V~

230 V~

Room 11

GROUND FLOOR

Common areas

Reception

KN

X B

us

01504 01500

01500 01540

Courtesy light(230 V~)

Electric lock

20453

SV

12-24 V~

Courtesy light(230 V~)(230 V~)

Contactwindow

Electric lock

01820

01504 01501

20451 20457

20848 + 20788

LightReception

BALLAST

0-10 V LN

V+

V+

V-

V-

L2

L1

L3

N

230 V~

01526 01528

Conference roomlight

01530

SV

Contactwindow

01820

20451

(230 V~)

20849 20840+ (2) 20841.0+ (2) 20841.2

NoteIn the diagram only some of the inputs and outputs equipping the devices are used.

Pull-cordbath-room

Lamp 1 (230 V~)

Lamp 2 (230 V~)

20457

Fridge-minibarDoor open indicator

Room ser-vice call button L

N

M

Fan-coil

230 V~

01522

Page 19: Even the most complex building can be simply managed to ...€¦ · Even the most complex building can be simply managed to KNX standard. WELL-CONTACT PLUS. 1 The system to control

17

General characteristics

whether a line can be considered as a floor or whether a line can cover a number of floors or, vice versa, whether the property is so large that covering a floor requires a number of lines (therefore, at the design stage, take account of the characteristics of a line in terms of number of devices and distances);

• the number of lines forming the system will determine the number of couplers that must be installed (the lines are con-nected together by line couplers that allow communication between devices belonging to different lines);

• atthe design stage, always try and bring each type of system into line with the diagram in the figure on page 857; this is to determine the correct position of the various devices within the system.

The installation examples (from page 902) give the layouts illustrating part of a typical hotel system; all the devices given in the examples are summarised in the general structure of the Well-contact Plus system (see the above table). The ground floor is composed of: reception, dining hall, administrative office, conference hall, technical room and store, while on the other floors there are the guest rooms. In each room on the first floor, the following items are installed: • an external transponder reader to access the room and

display the messages via the 4 front LEDs; • a reader with a pocket to activate the associated loads

(services); • a thermostat to control the temperature set-point; • a control with four independent push buttons for “do not

disturb”, “room service call” and “lights control” functions; In the suites, in place of the scenes with four independent push buttons, two 3-module touch screens are installed to manage lights, climate and any scenes.

The transponder readers are additionally used to distinguish between accesses to the offices and to the other places (store, technical room, etc.) located on the ground floor; this highlights how the Well-contact Plus system can easily be used in both hotels and the tertiary sector.

Example of system composition When creating an installation with the Well-contact Plus system the following components are used: • Powersupplies• Linecoupler• Transponder card reader• Transpondercard reader with pocket• Thermostat• Colour touch screen 4,3”• 3-module monochrome touch screen• Control with 4 independent push buttons• Transponder card reader/programmer• Input/output device• USBinterface

Preparing the system It is important, in the phase of preparing the system, to have a clear idea of which functions and applications are to be created and obviously this will depend on the type and complexity of the property where the installation is to be made. The system is composed of a range of 8 types of devices; it will be in the configuration phase with ETS where you assign the “task” that each of these devices must perform, which will be the input/output associations and the services to control.

As regards the actual preparation of the system and therefore laying out the cables and positioning the devices, it will be enough to take into account the characteristics given in the above table, observing the following precautions: • addupthepower inputs of the single devices (that must be

no more than 64 for each line segment) so as to determine the number of power supplies to install; if the absorption of the devices in a line is greater than the current delivered by the power supply (for instance 320 mA) it is necessary to con-nect an additional power supply or use a power supply able to deliver a greater current (for instance 640 mA);

• the transponder readers and the ones with a pocket are equipped with an additional supplementary power supply with respect to the connection on the KNX Bus 12-24 V.

• evaluate accurately, according to the size of the property,

Well-contact Plus system Characteristics

Bus devices Number of Bus devices for each single line segment max 64 (with power supply 640 mA)

Number of lines max 16 per field (total 241 lines)

Number of fields max 15

Maximum distance between two devices 700 m

Power supply Minimum working voltage 21 V d.c.

Number of power supplies for line segments max 2

Max current per line 640 mA

Minimum distance between the two power supplies 200 m

Topology Permitted connections linear, tree, star and mixed

Transmission Transmission technology decentralized, by event, serial, symmetrical

Transmission speed 9600 baud

Cable Bus cable section 2 x 2 x 0.8 mm2

Max length per line 1000 m

Page 20: Even the most complex building can be simply managed to ...€¦ · Even the most complex building can be simply managed to KNX standard. WELL-CONTACT PLUS. 1 The system to control

18

Automation for buildingsConfiguration software

ETS Software For the design, configuration of the various appliances and the commissioning of the system, installers have the ETS software (Engineering Tools Software), marketed by KNX Association. Using a PC and the ETS software, you address the different devices operating in the system and establish the related functional correlations (or group addresses). Establishing the functional correlations means using software to define how each device must intervene following the events occurring in the system, for instance which lamp or group of loads must switch on when a card is inserted in the reader with a pocket or a particular switch is pressed. The operating mode of KNX appliances is also determined by the application program selected from among the available ones for that device and by the appropriate configuration of the related operating parameters.

The application programs of Vimar KNX devices are freely available on the company’s website www.vimar.eu. The addresses and operating parameters are transferred to the various devices by connecting the PC to the KNX Bus via the KNX USB interface 01540. The ETS software utilizes simple graphical user interfaces that facilitate device configuration also in relation to the building’s layout.

Supervision and control at a higher level As already mentioned the KNX distributed intelligence systems also enable supervision and control at a higher level (centralized). Use of PCs and special software enables centralizing the system’s functions, but in no way does it jeopardize their operation if the PC is switched off or malfunctions.

230 V ~

Lettore a transponderInterfaccia USB

01540204571692714457

+ ETS+ Software applicativi

i - BUS KNX

Dispositivo di ingresso/uscita0152220451

1692114451

Termostato

1. Definition of physical addresses, functional correlations and operational parameters for the various system devices.

2. Transfer of addresses and parameters to the appliances.

3. At the end of the operations the PC can be removed, to be, if necessary, reconnected only for functions of diagnostics, changes to the parameters, addresses and functional or expansional correlations of the system.

Configuration phases

Note.In a Well-contact Suite system, when using the ETS project, there must be no groups with the same name: for example it will be necessary to distinguish between “power room 101” and “power room 102.” ETS project creation respecting this

clause will enable the Well-contact Suite software to distinguish automatically between the group addresses it must display and the ones it must mask for each room, considerably facilitating the task of room creation with Well-contact Suite.

ETS software window

Group addresses

Building topology

Buildings

Page 21: Even the most complex building can be simply managed to ...€¦ · Even the most complex building can be simply managed to KNX standard. WELL-CONTACT PLUS. 1 The system to control

19

Control equipment

Depending on the functions to be implemented, therefore, the most appropriate choices can be made to optimize the costs that the client will have to sustain.

Solutions for the Tertiary SectorThe versatility of these components and the Vimar WCS Office and WCS Office Client software enables flexible management of tertiary sector applications and particularly productions within the framework of office buildings; similar in use, the requirements in office buildings/blocks adhere perfectly to the functions performed by the Vimar components with the KNX standard. Thanks to the peculiarities of the KNX standard it is possible to expand the system at any time with devices already present on the market able to satisfy even the most sophisticated and specific applications, such as for instance controlling the opening of a passage, complete management of lights and temperature, programmable also by floor, side of exposure or single office. The system applications can therefore be the most varied; from access diversification to customizing each single office with the generation of cards that also allows access to common rooms such as, for instance, general entrances, canteens/restaurants, reserved lounges, conference rooms, etc., all using the transponder reader. With the aid of the pocket reader it will then also be possible, in all those rooms not normally controlled by time programs or motion detectors, to manage the lighting or temperature (energy savings).

The topic of lighting in offices is by now the subject of specific design studies; switching on lamps not only with a manual control but also with programs linked to time or to the side of exposure to sunlight enables significant energy savings; with the input/output devices it is possible, for instance, to connect light sensors capable of detecting the degree of brightness and switch lights on and off in a differentiated manner according to the set threshold value. With these same devices it is also possible to transmit status or alarm signals from auxiliary contacts or remote sensors that can be displayed both on the readers and on the monitoring PC (if applicable). Lastly, as regards temperature control, in modern office buildings the possibility of switching on the heating or air-conditioning in a differentiated manner has become an increasingly requested comfort requirement especially for the savings provided in terms of energy optimization; all of this can be performed by suitably programming the thermostats of the Well-contact Plus system.

Well-contact Suite SoftwareWell-contact Suite (WCS) is a family of software products (WCS Basic, WCS Top, WCS Client, WCS Office, WCS Client Office and WCS Management) that enables managing/supervising the entire system with operations of check-in, room status, events memory, alarm control, temperature control, guest file, etc.. The following chart gives the functions of the Suite.

Controllable functionsCard identification

Guest Room Check-in\Check-out

Management of Services and Privileges (creation of cards with services enabling)

Access log and display

Stopping access to single rooms

Room booking

Displaying room reserved, booked, occupied, identification of guest presence

Displaying length of stay, day of departure

Checking PW of personnel with hourly and area limitation

Diversification of users (guests, service personnel, etc.)

Displaying different types of alarms and changing the warning status

Protection with unique Hardware Key for guest

Searching and exporting entry report

Checking and managing transit through common areas

Advanced search functions (by text categories)

Displaying service requests

Managing the records of the hotel’s staff and guests

Guest book with any saved parameters

Supervision (temperatures, I/O, alarms, security, lights)

Guest management with Client-Server Logic on local area network or remotely via web

Levels of protection (password) for differentiated access

Seven levels of access “privileges” to be associated with the software users

Possibility of managing scenes and commands of virtual devices

Room supervision screen Customer card screen

Management and supervision software

Page 22: Even the most complex building can be simply managed to ...€¦ · Even the most complex building can be simply managed to KNX standard. WELL-CONTACT PLUS. 1 The system to control

20

Control equipment - SPECIFICATIONS

Automation for buildings

4,3” colour touch screen for monitoring and controlTouch screen to be used in the automation system for control-ling lights, roller shutters, air-conditioning and scenes.The device is configured with the configurer software of the Well-contact Plus touch screens connecting the interface 01998.U to the special connector on the front of the device. The touch screen allows the supervision and control of all the devices in the automation system that have been configured.

Technical specifications• TFT 4,3” display• rated supply voltage: 12 - 30 V d.c. • current absorption: 60 mA at 30 V d.c. and 120 mA at 12 V d.c.,

10 mA from the Bus•terminals: -power supply 12 - 30 V d.c. - KNX TP Bus• possiblefunctions:

- ON/OFF switch (lights on/off)- roller shutter and blinds control- dimmer control (light dimming)

- scene activation- aircon control- display of the main physical data (m/s, m/s2 A, V, °C, °F, °K,

Lux, etc.)• number of pages: up to 60 with 8 icons each (one dimmer/

roller shutters occupies 2 icons)• operating temperature: -5 °C - +45 °C (for indoor use)

ConfigurationThe touch screen is configured with the configurer software and the programming interface 01998.U; using the ETS project database with which the system was configured, select the functions (groups, scenes, etc.) that you want to control via the touch screen. In addition, it is possible to use the interface 01998.S downloading the KNX touch screen configurer software from the website www.vimar.eu.

Conformity to StandardsEMC Directive, Standard EN 50428, EN 50090-2-2

OperationTouch the icons on the main screen for room control and the touch screen settings to access the following screens that enable checking and controlling the system with the icons displayed.

Front view and connections of touch screen

KNX TP Bus terminals

power supply terminals 12 - 30 V d.c.

display

PIN-STRIP connector for connecting with the interface 01998.U

Main Menu

Room Selection Settings

Example of “white skin” configuration of the touch screen

Room control Room temperature

Control and supervision - TECHNICAL CHARACTERISTICS

Page 23: Even the most complex building can be simply managed to ...€¦ · Even the most complex building can be simply managed to KNX standard. WELL-CONTACT PLUS. 1 The system to control

21

Control equipment

Side views show the overall dimensions and the flush depth in mm

11 39,9

119,

6

140,1

115,

7

89,7

136

144

50,9

20848grey

20848.NNext

20848.Bwhite

14848white

14848.SLSilver

Colour touch screen 4,3”Colour touch screen 4,3" for control, Well-contact Plus, complete with built-in 8-module mounting frame

20698...

14668...

20668...

V71318 20788grey

14788white

14788.SLSilver

20788.Bwhite

20788.NNext

Accessories for 4,3” colour touch screen V71318 Flush mounting box, 8 modules (4+4), GW 650 °C, blue20788 .B .N Desktop base for 4,3” colour touch screen, 8 modules (4+4) Eikon. To be completed with Classic or Round cover plate14788 .SL As above, for Plana 20668... Eikon: Classic 8-module cover plate (4+4): Bright (varnished metal), Galvanic (galvanic metal), Stainless steel, Stone, Wood

(solid wood), Glass (crystal) and Reflex (technopolymer)20698... Eikon: Round 8-module cover plate (4+4): Bright (varnished metal), Galvanic (galvanic metal), Stainless steel, Wood (solid wood)

and Glass (crystal)14668... Plana: 8-module cover plate (4+4), available in technopolymer and Reflex

PLANA

EIKON

Control and supervision

Page 24: Even the most complex building can be simply managed to ...€¦ · Even the most complex building can be simply managed to KNX standard. WELL-CONTACT PLUS. 1 The system to control

22

Control equipment - SPECIFICATIONS

Automation for buildings

3-module monochrome touch screen for room control Device with a touch screen to be used in the automation system for controlling lights, roller shutters, air-conditioning and scenes. The device is configured with the configurer software of the Well-contact Plus touch screens connecting the interface 01998.U to the special connector on the back of the device. The touch screen can be installed either horizontally or vertically.

Technical specifications• ratedsupply voltage: Bus 30 V d.c. SELV• current absorption: 10 mA• terminals:KNXTP Bus• possiblefunctions:

- ON/OFF control (lights on/off)- roller shutter control- dimmer control (light dimming)- scenario activation- aircon control- display of the main physical data (m/s, m/s2 A, V, °C, °F, °K,

Lux, etc.)- up to 3 screens that can be configured for controlling a room

• number of pages: 3 with up to 8 icons each (one dimmer/roller shutters occupies 2 icons)

• operating temperature: -5 °C - +45 °C (for indoor use)

ConfigurationUsing the ETS project database with which the system was configured, select the functions (groups, scenes, etc.) that you want to control via the touch screen in addition, it is possible to use the interface 01998.S downloading the Well-contact Plus touch screen configurer software from the website www.vimar.eu.

OperationTouch the icons on the main screen to access other icons that enable controlling the associated devices and make the settings (date, time, etc.) on the touch screen.

Conformity to StandardsEMC directiveStandard EN 50428, EN 50090-2-2

Main menu

Display Setting menu Room Control menu Information menu

display

Front view and connections of touch screen

PIN-STRIP connector for connecting to the interface 01998.U

KNX TP Bus terminals

Control and supervision - TECHNICAL CHARACTERISTICS

Page 25: Even the most complex building can be simply managed to ...€¦ · Even the most complex building can be simply managed to KNX standard. WELL-CONTACT PLUS. 1 The system to control

23

Control equipment

Side views show the overall dimensions and the flush depth in mm

16849grey

16849.Bwhite

14849.SLSilver

14849white

20849.NNext

20849.Bwhite

20849grey

37

46,5

67,3

49

36,8

47

74,8

50,2

36

46,5

67,3

49

EIKON

IDEA

PLANA

3-module monochrome touch screenMonochrome touch screen for local control, Well-contact Plus - 3 modules

Control and supervision

Page 26: Even the most complex building can be simply managed to ...€¦ · Even the most complex building can be simply managed to KNX standard. WELL-CONTACT PLUS. 1 The system to control

24

Control equipment - SPECIFICATIONS

Automation for buildings

Front view and connections

Control with four independent push buttonsThe device is equipped with four independent buttons that can be used for switching ON/OFF, controlling roller shutters and adjusting lights, to be completed with button caps. The device must be completed with simple or fixed, 1- and/or 2-module button caps. The simple button caps enable identifying the programmed push button, while the fixed button caps are used to exclude buttons not yet configured.

Important: Bear in mind that the 1- and/or 2-module button caps must be fitted on the control keeping the backlighting window facing the centre of the control. When ordering custom designed button caps, besides selecting the pictogram, you must also state whether it is the top or bottom button cap to be customized.

The configuration of the device, physical address and parameters takes place through the ETS software. If the input/output device is loaded with an incorrect ETS application, the red LED will flash (“device type” error). To restore the desired configuration, load the device with the correct ETS application.

Technical specifications• supply voltage: Bus 30 V d.c. SELV• current absorption: 10 mA• terminals: KNX TP Bus• operatingtemperature: -5 °C - +45 °C (for indoor use)

OperationThe device can be used in two different modes: • functions with independent push buttons: - send ON, send OFF, timed ON - ON and OFF switch on the up and down side - call up scene, save scene - send value - dimmer control - toggle • functions with 2 associated channels: - ON/OFF switch - dimmer control - roller shutter control

Conformity to StandardsEMC directive Standard EN 50090-2-2, EN 50428

LED LED

configuration button

Removable Bus connection terminal

Insulating sheath providing electrical insulation from the mains cables at 230 V~

Bus terminal

Control with four independent push buttons: Bus cable connection

Control and supervision - TECHNICAL CHARACTERISTICS

Page 27: Even the most complex building can be simply managed to ...€¦ · Even the most complex building can be simply managed to KNX standard. WELL-CONTACT PLUS. 1 The system to control

25

Control equipment

Side views show the overall dimensions and the flush depth in mm

EIKON

IDEA

PLANA

Control with four independent push buttonsControl device with four independent push buttons, KNX standard, visible in darkness, to be completed with button caps - 2 modules

14840white

16840grey

16840.Bwhite

20840grey

49,8

50

19,5

27,2

Control and supervision

Page 28: Even the most complex building can be simply managed to ...€¦ · Even the most complex building can be simply managed to KNX standard. WELL-CONTACT PLUS. 1 The system to control

26

Control equipment - SPECIFICATIONS

Automation for buildings

EIKON For articles in the white version: add .B to the code of the article in the grey version.For articles in the Next version: add .N to the code of the article in the grey version.

2-module control device 1-module interchangeable button caps 2-module interchangeable button caps

Simple20840

Simple button caps

Without symbol20841

“O” symbol20841.0

“I” symbol20841.1

Without symbol20842

“O” symbol20842.0

“I” symbol20842.1

“I/O” symbol20841.2

With directional arrows20841.3

With regulation symbol20841.4

“I/O” symbol20842.2

With directional arrows20842.3

With regulation symbol20842.4

Fixed button capsWithout symbol20843

Without symbol20843

PLANA For articles in the Silver version: add .SL to the code of the article in the white version.

2-module control device 1-module interchangeable button caps 2-module interchangeable button caps

Simple 14840

Simple button caps

Without symbol14841

“O” symbol14841.0

“I” symbol14841.1

Without symbol14842

“O” symbol14842.0

“I” symbol14842.1

“I/O” symbol14841.2

With directional arrows14841.3

With regulation symbol14841.4

“I/O” symbol14842.2

With directional arrows14842.3

With regulation symbol14842.4

Fixed button capsWithout symbol14843

Without symbol14843

IDEA For articles in the white version: add .B to the code of the article in the grey version.

2-module control device 1-module interchangeable button caps 2-module interchangeable button caps

Simple16840

Simple button caps

Without symbol16841

“O” symbol16841.0

“I” symbol16841.1

Without symbol16842

“O” symbol16842.0

“I” symbol16842.1

“I/O” symbol16841.2

With directional arrows16841.3

With regulation symbol16841.4

“I/O” symbol16842.2

With directional arrows16842.3

With regulation symbol16842.4

Fixed button capsWithout symbol16843

Without symbol16843

Eikon Round cover plate

2-central-module mounting frame

Device with 4 independent push buttons

Customized 2-module simple button caps

1-module simple button caps, blank and with arrows

1-module fixed button caps 2-module

fixed button caps

Example of installation of 1- and 2-module button caps with Eikon series

Note.The simple button caps enable identifying the programmed push button, while the fixed button caps are used to exclude buttons not yet configured.

Interchangeable buttons for control device - TECHNICAL CHARACTERISTICS

Page 29: Even the most complex building can be simply managed to ...€¦ · Even the most complex building can be simply managed to KNX standard. WELL-CONTACT PLUS. 1 The system to control

27

Control equipment

140 141 142 143 144138 139

64 65 66 67 68 69 70 71 72 73 74

75 76 77 78 79 80 81 82 83 84

88 289 290 91 92 293 294 295 296

297 298 299 2100 2101 2102 2103 2104 2105 106 107

85

86 87

110 111108 109

112 114113 115 116 117 118 119 120 121 122

01 02 03 04 05 06 07 08 09 1110

12 13 14 15 16 17 18 19 20 21 222

223come in

224bathroom

225cellar

226close

227 28garage

229general

230 231back

232 33

34 235 236 237

light OFF

ON storeroom stairs attic238

terrace49

alarm50

do notdisturb

open

gardenoutside

39 40 41

4942alarm

50 123 124 125 126 127 128 129 130

131

do notdisturb

132 133 134 135 136 137

54 55 56 57 58 59 60 61

222 223 224 225 226 227 28garage

229 230

231 232 33 34 235 236 237OFF ON

238

62 63

5351 52

come in bathroom cellar close generalopen outside garden

back light storeroom stairs attic terrace

Libraries of standard lettering and symbols for button caps ( symbols already contemplated in the catalogue)

B1

B2

A1

A2

B1

B2

A1

A2

mezzo tasto superiore

mezzo tasto inferiore

14 mm 14 mm

7 m

m

7 m

m

EIKON

IDEA

PLANA

A1 and A2:customizable area (14x7 mm).

B1 and B2:LED backlighting translucent window.

Note.The 1 or 2 module button cap must always be fitted keeping the window facing the centre of the control. When selecting the pictogram you must specify whether the button cap is top or bottom.

Customizable area of the 1- and 2-module button caps

Symbols for customizing buttons

top half button cap

bottom half button cap

Page 30: Even the most complex building can be simply managed to ...€¦ · Even the most complex building can be simply managed to KNX standard. WELL-CONTACT PLUS. 1 The system to control

28

Control equipment - SPECIFICATIONS

Automation for buildings

Eikon 1-module interchangeable half-button caps20841 .B .N Four interchangeable half-button caps, without symbol20841.0 .B .N Four interchangeable half-button caps, O symbol20841.1 .B .N Four interchangeable half-button caps, I symbol20841.2 .B .N Four interchangeable half-button caps, I O symbols

Idea 1-module interchangeable half-button caps16841 .B Four interchangeable half-button caps, without symbol16841.0 .B Four interchangeable half-button caps, O symbol16841.1 .B Four interchangeable half-button caps, I symbol16841.2 .B Four interchangeable half-button caps, I O symbols

Plana 1-module interchangeable half-button caps14841 .SL Four interchangeable half-button caps, without symbol14841.0 .SL Four interchangeable half-button caps, O symbol14841.1 .SL Four interchangeable half-button caps, I symbol14841.2 .SL Four interchangeable half-button caps, I O symbols

20841.Bwhite

16841.Bwhite

14841.SLSilver

20841.1.Bwhite

16841.1.Bwhite

14841.1.SLSilver

20841.0.Bwhite

16841.0.Bwhite

14841.0.SLSilver

20841.2.Bwhite

16841.2.Bwhite

14841.2.SLSilver

20841.NNext

20841.1.NNext

20841.0.NNext

20841.2.NNext

20841grey

16841grey

14841white

20841.1grey

16841.1grey

14841.1white

20841.0grey

16841.0grey

14841.0white

20841.2grey

16841.2grey

14841.2white

EIKON

IDEA

PLANA

Interchangeable buttons for control device

Page 31: Even the most complex building can be simply managed to ...€¦ · Even the most complex building can be simply managed to KNX standard. WELL-CONTACT PLUS. 1 The system to control

29

Control equipment

Side views show the overall dimensions and the flush depth in mm

Eikon 1-module interchangeable half-button caps20841.3 .B .N Four interchangeable half-button caps, directional arrows symbol20841.4 .B .N Four interchangeable half-button caps, regulation symbol20843 .B .N Four blank interchangeable fixed half-button caps, without symbol

Idea 1-module interchangeable half-button caps16841.3 .B Four interchangeable half-button caps, directional arrows symbol16841.4 .B Four interchangeable half-button caps, regulation symbol16843 .B Four blank interchangeable fixed half-button caps, without symbol

Plana 1-module interchangeable half-button caps14841.3 .SL Four interchangeable half-button caps, directional arrows symbol14841.4 .SL Four interchangeable half-button caps, regulation symbol14843 .SL Four blank interchangeable fixed half-button caps, without symbol

20841.3.Bwhite

16841.3.Bwhite

14841.3.SLSilver

20841.4.Bwhite

16841.4.Bwhite

14841.4.SLSilver

20843.Bwhite

16843.Bwhite

14843.SLSilver

20841.3.NNext

20841.4.NNext

20843.NNext

20841.3grey

16841.3grey

14841.3white

20841.4grey

16841.4grey

14841.4white

20843grey

16843grey

14843white

EIKON

IDEA

PLANA

Interchangeable buttons for control device

Page 32: Even the most complex building can be simply managed to ...€¦ · Even the most complex building can be simply managed to KNX standard. WELL-CONTACT PLUS. 1 The system to control

30

Control equipment - SPECIFICATIONS

Automation for buildings

Eikon 2-module interchangeable half-button caps20842 .B .N Two interchangeable half-button caps, without symbol20842.0 .B .N Two interchangeable half-button caps, O symbol20842.1 .B .N Two interchangeable half-button caps, I symbol20842.2 .B .N Two interchangeable half-button caps, I O symbols

Idea 2-module interchangeable half-button caps16842 .B Two interchangeable half-button caps, without symbol16842.0 .B Two interchangeable half-button caps, O symbol16842.1 .B Two interchangeable half-button caps, I symbol16842.2 .B Two interchangeable half-button caps, I O symbols

Plana 2-module interchangeable half-button caps14842 .SL Two interchangeable half-button caps, without symbol 14842.0 .SL Two interchangeable half-button caps, O symbol14842.1 .SL Two interchangeable half-button caps, I symbol14842.2 .SL Two interchangeable half-button caps, I O symbols

20842.Bwhite

16842.Bwhite

14842.SLSilver

20842.1.Bwhite

16842.1.Bwhite

14842.1.SLSilver

20842.0.Bwhite

16842.0.Bwhite

14842.0.SLSilver

20842.2.Bwhite

16842.2.Bwhite

14842.2.SLSilver

20842.NNext

20842.1.NNext

20842.0.NNext

20842.2.NNext

20842grey

16842grey

14842white

20842.1grey

16842.1grey

14842.1white

20842.0grey

16842.0grey

14842.0white

20842.2grey

16842.2grey

14842.2white

EIKON

IDEA

PLANA

Interchangeable buttons for control device

Page 33: Even the most complex building can be simply managed to ...€¦ · Even the most complex building can be simply managed to KNX standard. WELL-CONTACT PLUS. 1 The system to control

31

Control equipment

Side views show the overall dimensions and the flush depth in mm

Eikon 2-module interchangeable half-button caps20842.3 .B .N Two interchangeable half-button caps, directional arrows symbol20842.4 .B .N Two interchangeable half-button caps, regulation symbol20844 .B .N Two blank interchangeable fixed half-button caps, without symbol

Idea 2-module interchangeable half-button caps16842.3 .B Two interchangeable half-button caps, directional arrows symbol16842.4 .B Two interchangeable half-button caps, regulation symbol16844 .B Two blank interchangeable fixed half-button caps, without symbol

Plana 2-module interchangeable half-button caps14842.3 .SL Two interchangeable half-button caps, directional arrows symbol14842.4 .SL Two interchangeable half-button caps, regulation symbol14844 .SL Two blank interchangeable fixed half-button caps, without symbol

20842.3.Bwhite

16842.3.Bwhite

14842.3.SLSilver

20842.4.Bwhite

16842.4.Bwhite

14842.4.SLSilver

20844.Bwhite

16844.Bwhite

14844.SLSilver

20842.3.NNext

20842.4.NNext

20844.NNext

20842.3grey

16842.3grey

14842.3white

20842.4grey

16842.4grey

14842.4white

20844grey

16844grey

14844white

EIKON

IDEA

PLANA

Interchangeable buttons for control device

Page 34: Even the most complex building can be simply managed to ...€¦ · Even the most complex building can be simply managed to KNX standard. WELL-CONTACT PLUS. 1 The system to control

32

Control equipment - SPECIFICATIONS

Automation for buildings

Passive infrared presence detectorThe device when activated by the IR sensor tripping (persons or animals moving through the sensor’s range of action) and/or by the light sensor, sends a message on the Bus.

Technical specifications• ratedsupply voltage: Bus 30 V d.c. SELV• current absorption: 10 mA•maximumrange:10 m• connectionterminals: KNX TP Bus • operatingtemperature: -5°C to +45°C (indoor use)

OperationThe device, whenever motion is detected, sends a message on the KNX Bus turning on the indicator LED according to the set brightness threshold (lights on/off according to the brightness in the room). The detector is also used to manage movement signals coming from any other KNX device in MASTER/SLAVE mode. The configuration of the device, physical address and parameters takes place through the ETS software.

Conformity to StandardsEMC DirectiveStandards EN 50130-4, EN 50428 1,2

0

A = 3 rays +6B = 6 rays +0C = 5 rays -20D = 3 rays -30

Detection range

- 112 horizontally - 36 min. vertically - 17 zones on 4 levels• Range: 10 m max (8 m typically)

1,5 8m

0

B

A

CD

112

B

BB B

B

BC

D D

A C CA

C

C

A

1,5 m

8 m

D

10

Detection

1,2

0

A = 3 rays +6B = 6 rays +0C = 5 rays -20D = 3 rays -30

Detection range

- 112 horizontally - 36 min. vertically - 17 zones on 4 levels• Range: 10 m max (8 m typically)

1,5 8m

0

B

A

CD

112

B

BB B

B

BC

D D

A C CA

C

C

A

1,5 m

8 m

D

10

Detection

Presence detector coverage areas

Vertical plane

Horizontal plane

Control and supervision - TECHNICAL CHARACTERISTICS

Front view and connections of motion sensor

A B C

Bus terminals

A: IR sensorB: LEDC: configuration button

Orientable supportsFor passive infrared motion detectors.

Technical specifications• allowsflushmounting installation (with adaptor) in rectangular

or round boxes ø 60 mm and surface mounting installation (with a frame)

• thesupports can be arranged as shown in the figure along-side

30 20

135 135

30 20

Vertical orientation angle Horizontal orientation angle

Orientable supports

Page 35: Even the most complex building can be simply managed to ...€¦ · Even the most complex building can be simply managed to KNX standard. WELL-CONTACT PLUS. 1 The system to control

33

Control equipment

Side views show the overall dimensions and the flush depth in mm

EIKON

20850grey

20850.NNext

20850.Bwhite

16850grey

16850.Bwhite

14850white

14850.SLSilver

43,7

25,5 44,8

49

26

43,8

49,8

50

26,5

43,5

44,8

49

IDEA

PLANA

Presence detectorPassive infrared presence detector, KNX standard - 2 modules

Control and supervision

20636grey

20636.NNext

20636.Bwhite

16836.Bwhite

16836grey

14636white

14636.SLSilver

114

114

85,6 63

114

114

85,6 63

114

114

85,6 63

EIKON

IDEA

PLANA

Orientable supportsOrientable support - 2 modules

Page 36: Even the most complex building can be simply managed to ...€¦ · Even the most complex building can be simply managed to KNX standard. WELL-CONTACT PLUS. 1 The system to control

34

Control equipment - SPECIFICATIONS

Automation for buildingsOrientable supports - TECHNICAL CHARACTERISTICS

16831

16836

16935

16831

20636

20485

Example

Eikon Idea Plana

14636

14485

16831.01

Frame for surface mounting orientable support

Example

Eikon Idea Plana

Adaptor for flush mounting orientable support

20637 16830 14637

20636 16836 14636

Page 37: Even the most complex building can be simply managed to ...€¦ · Even the most complex building can be simply managed to KNX standard. WELL-CONTACT PLUS. 1 The system to control

35

Control equipment

Side views show the overall dimensions and the flush depth in mm

14637white

14637.SLSilver

16830grey

20637grey

20637.NNext

20637.Bwhite

44,8

49

36,5

46

44,8

49

36,5

46

37,5

EIKON

IDEA

PLANA

Adaptor for flush mounting orientable supportAdaptor for flush mounting orientable supports

Orientable supports

Frame for surface mounting orientable supportFrame for surface mounting orientable supports

16831grey

16831.NNext

16831.01white

16831.Bwhite

16831grey

16831.01white

16831.SLSilver

14,5

79,5

14,5

79,5

14,5

79,5

EIKON

PLANA

IDEA

Page 38: Even the most complex building can be simply managed to ...€¦ · Even the most complex building can be simply managed to KNX standard. WELL-CONTACT PLUS. 1 The system to control

36

Control equipment - SPECIFICATIONS

Automation for buildings

• Configuration BUTTON: button for switching between normal mode or programming mode or detecting the physical address.

• LED off: "normal operation" indicator.

• Red LED: “addressing mode” indicator (the LED goes out automatically after programming the physical address).

Front view

Alimentazione12 -24 V ~

Ingresso1

Ingresso2

Relè 1

LED

PULSANTEconfigurazione

C NO

Comuneingressi1 e 2

LineaBUSRelè 2

C NO

Connections

Transponder card readers for outside the roomThe device, with transponder cards, enables controlling entry to the rooms where it is installed externally. The transponder reader has two relays to control the door lock, a courtesy light, or for other uses; the device is moreover equipped with two inputs for connecting electrical equipment of the ON/OFF type (for instance to control the door open or closed switch, a magnetic contact for signalling an open or closed window, bathroom ceiling pull-cord alarm, etc.).On the front of the reader there are four LEDs each of which associated with an icon for signalling the following states: • access (entry allowed or entry denied); • guest status (room occupied or do not disturb); • call status (rescue request with bathroom ceiling pull-cord,

room service call, etc.); • services status (make up room, etc.). The transponder reader is able to dialogue with other KNX devices.

Technical specifications• Bussupply voltage: 30 V d.c. SELV• auxiliarysupply voltage: 12-24 V ± 20% SELV• absorption: 10 mA on the Bus; max 130 mA on the

supplementary power supply 12-24 V• terminals: -KNXTP Bus - supplementary power supply (12-24 V ) - digital inputs for 2 NO or NC contacts (with no

potential, SELV) - outputs for 2 relays NO (24 V~ SELV 4 A

cos  1; 24 V~ SELV 2 A cos 0.6)•maximum distance of the input contact from the device: 30 m

with twisted cable• this device contains only SELV circuits that must be kept

separate from circuits with dangerous voltage• operating temperature: -5 °C - +45 °C (for indoor use)

OperationThe configuration of the reader, physical address and parameters (NO or NC contact inputs, one-, two-position stable or timed relay outputs, etc.) is done with the ETS software. If the transponder reader is loaded with an incorrect ETS application, both the red LED on the back of the device and the front LEDs 2, 3 and 4 will blink (“device type” error). To restore the desired configuration, load the device with the correct ETS application.The card is read by putting it in front of the reader that in sequence checks: • “systemcode” (whether consistent);• “date and time” field (if enabled, it checks whether the validity has

expired);•“password” (checks all the codes associated with it and

enabled, such as guest code, service code, timeframes).

With ETS it is possible to set the following parameters (can be selected directly from the graphic windows):• card information;• device configuration;• general settings;• configuration of channels;• inputsAand B;• outputsAand B.

Conformity to StandardsR&TTE DirectiveStandards EN 50090-2-2, EN 50428, EN 300 330-2, EN 301 489-3

LED STATUSLED 1:- steady green: signalling “Entry allowed” (the LED remains illuminated for

approximately 3 s). - blinking green: signalling if the timeframe is not valid (the LED blinks for

approximately 3 s). - steady red: signalling “Entry denied” (the LED remains illuminated for

approximately 3 s).- blinking red: signalling if the expiry date is not valid. - steady amber: signalling if the system coding is not valid- blinking amber: signalling if the day of the week is not valid.- blinking red/green: synchronize the device’s internal clock.LED 2: - red: signalling “Do not disturb.” - blinking red: signalling “Room occupied.” LED 3: amber - signalling “Room service call.” LED 4: green - signalling “Make up room.”

Note.The meaning taken on by the LEDs 2, 3 and 4 depends on the subjects of communication (therefore the functions) that are configured in the reader with the ETS software. For all the applications in which the device is configured with different functions and LED indications to the standard ones, the customer can ask Vimar to customize the symbols on the front of the reader with a laser.

Access control - TECHNICAL CHARACTERISTICS

Page 39: Even the most complex building can be simply managed to ...€¦ · Even the most complex building can be simply managed to KNX standard. WELL-CONTACT PLUS. 1 The system to control

37

Control equipment

Side views show the overall dimensions and the flush depth in mm

Please, contact the commercial network for further information

Access control

20457grey

20457.Bwhite

20457.NNext

16927grey

16927.Bwhite

14457white

14457.SLSilver

Transponder card readers for outside the roomTransponder card reader for installation outside room, KNX standard, 2 relay outputs NO 4 A 24 V~, 2 digital inputs, power supply 12-24 V~ 50-60 Hz and 12-24 V d.c. (SELV) - 3 modules. Supplied without transponder card

EIKON

IDEA

PLANA

Page 40: Even the most complex building can be simply managed to ...€¦ · Even the most complex building can be simply managed to KNX standard. WELL-CONTACT PLUS. 1 The system to control

38

Control equipment - SPECIFICATIONS

Automation for buildings

Illuminated pocket

Front viewTransponder card reader with pocket for inside roomThe device enables checking for the presence in the room of the guest or the service staff by unambiguously identifying the transponder card inserted. The reader with a pocket is equipped with two relays that can be configured for managing door locking, controlling a courtesy light, optimizing energy consumption or for even more uses; the device is moreover equipped with two inputs for connecting electrical equipment of the ON/OFF type (for instance to control the door open or closed switch, a magnetic contact for signalling an open or closed window, bathroom ceiling pull-cord alarm, etc.). The device is able to dialogue with other KNX devices.

Technical specifications• Bussupply voltage: 30 V d.c. SELV• auxiliary/supplementary rated supply voltage: -12-24 V ± 20%

SELV• absorption: 10 mA on the Bus, 130 mA max on the

supplementary power supply (at 12-24 V )• terminals: - TP bus - supplementary power supply (12-24 V ); - digital inputs for 2 NO or NC contacts (with no

potential, SELV) - outputs for 2 relays NO (24 V~ SELV 4 A cos

1; 24 V~ SELV 2 A cos 0.6)•maximumdistance of the input contact from the device: 30 m with twisted cable• this device contains only SELV circuits that must be kept

separate from circuits with dangerous voltage• operating temperature: -5 °C - +45 °C (for indoor use)

OperationThe configuration of the reader, physical address and parameters (NO or NC contact inputs, normal or timed relay outputs, etc.) is done with the ETS software.If the reader with a pocket is loaded with an incorrect ETS application, the pocket backlighting and the red LED on the back will blink (“device type” error).To restore the desired configuration, load the device with the correct ETS application. The card is read by putting it into the special pocket that is always illuminated when there is no card in it. After inserting the card, the device checks the following in sequence: •“systemcode” (whether consistent) •“dateandtime” field (if enabled, it checks whether the validity

has expired); • “password” (checks all the codes associated with it and

enabled, such as guest code, service code, timeframes).

With ETS it is possible to set the following parameters (can be selected directly from the graphic windows):• cardinformation;• device configuration;• general settings;• configuration of channels;• inputsAand B;• outputsAandB.

Conformity to StandardsR&TTE DirectiveStandards EN 50090-2-2, EN 50428, EN 300 330-2, EN 301 489-3

POCKET LIGHTING

On: the card is not inserted.

Off: the card is inserted.

Blinking slowly or always off: the card is not recognized and therefore the functions are not activated.

Fast blink: synchronize the device’s internal clock.

Configuration BUTTON:button for switching between normal mode or programming mode or detecting the physical address.

LED off: "normal operation" indicator.

Red LED: indicator “addressing mode” (the LED goes out automatically after programming the physical address).

Supply12 -24 V ~

Input1

Input2

Relay 1

LED

configurationBUTTON

C NO

Commoninput

1 and 2

BuslineRelay 2

C NO

Connections

Access control - TECHNICAL CHARACTERISTICS

Page 41: Even the most complex building can be simply managed to ...€¦ · Even the most complex building can be simply managed to KNX standard. WELL-CONTACT PLUS. 1 The system to control

39

Control equipment

Side views show the overall dimensions and the flush depth in mm

Please, contact the commercial network for further information

Access control

49

67,337

56,5

74,8

50,2

56,5

36,5

67,3

49

56,5

37

Transponder card reader with pocket for inside roomTransponder card reader with vertical pocket for installation inside room, KNX standard, 2 relay outputs NO 4 A 24 V~,2 digital inputs, supplementary power supply 12-24 V~ 50-60 Hz and 12-24 V d.c. (SELV) - 3 modules

20453grey

20453.Bwhite

20453.NNext

16923grey

16923.Bwhite

14453white

14453.SLSilver

IDEA

PLANA

EIKON

Page 42: Even the most complex building can be simply managed to ...€¦ · Even the most complex building can be simply managed to KNX standard. WELL-CONTACT PLUS. 1 The system to control

40

Control equipment - SPECIFICATIONS

Automation for buildings

Front view Transponder card reader/programmer with vertical pocket in table mounting box The device enables programming and coding the transponder cards to use with the readers 20457, 16927, 14457 and the pockets 20453, 16923 and 14453 (in the respective colour variations). The reader/programmer must be connected to a personal com-puter on which the Well-contact Suite software must be installed for creating and managing the necessary data for the configura-tion of the cards according to the different requirements. The device is equipped with a cable for connecting the USB port of the PC and a backlit pocket for signalling card reading/writing. It is installable in table mounting box and needs no driver.

Technical specifications• power supply: from USB port (5 V d.c.)• consumption: 130 mA• connection: USB 1.1 or higher cable for connection to PC • this device contains only SELV circuits that must be kept

separate from circuits with dangerous voltage • operatingtemperature: -5 °C - +45 °C (for indoor use)• not compatible with the old Well-contact system

NoteThe device is supplied by the PC via the USB port; therefore, in the phase of sizing the system (number of necessary power supplies), you must not take account of the consumption of the device.

OperationProgramming takes place by inserting the transponder card (that can be blank or already used previously) into the reader pocket after having selected the writing command with the PC software. If, 30 s after the command, no card is inserted into the pocket, the programming command is cancelled and the PC is sent a message telling it that the device is awaiting data. The cards are read in a similar manner; the card is inserted into the pocket of the device that will read the saved data (codes, passwords, etc.) and will transmit them to the PC. The reader/programmer enables programming and/or reading the following data: • “Systemcode” (that identifies the installation or the name of

the hotel or the site where the system is installed); • “Password” (of the client or service); • “Dateand time” (day/month/year).

Conformity to StandardsR&TTE DirectiveStandards EN 55022, EN 55024, EN 300 330-2, EN 301 489-3

Transponder card customizing The card can be customized on the back with colour or black and white graphics.

Technical specifications•Mifare® at 13.56 MHz• freememory banks for multi-applications (e.g. money)• 7accesslevels (e.g., guest, service, etc.)• notcompatible with the old Well-contact system

POCKET LIGHTINGOn: the card is inserted Off: the card is not inserted Blinking (for approximately 3 s): in the phase of programming

Eikon

Idea

Connections

Plana

Access control - TECHNICAL CHARACTERISTICS

Page 43: Even the most complex building can be simply managed to ...€¦ · Even the most complex building can be simply managed to KNX standard. WELL-CONTACT PLUS. 1 The system to control

41

Control equipment

Side views show the overall dimensions and the flush depth in mm

Please, contact the commercial network for further information

Access control

20450.Bwhite

20450.NNext

16920.Bwhite

14450white

14450.SLSilver

88,8 148,6

74,9

111 121,6

77,4

142,5

74,4

89,2

01598

20450grey

16920grey

Transponder card reader/programmerTransponder card reader/programmer with vertical pocket in table mounting box, 3 modules for Idea, 4 modules for Eikon and PlanaTo complete with cover plate

Transponder card 01598 Programmable transponder card for readers inside and outside the room, customizable back

IDEA

PLANA

EIKON

Page 44: Even the most complex building can be simply managed to ...€¦ · Even the most complex building can be simply managed to KNX standard. WELL-CONTACT PLUS. 1 The system to control

42

Control equipment - SPECIFICATIONS

Automation for buildings

Electronic thermostatThis device is suited to control room temperature (heating and air-conditioning); a number of thermostats can be connected together and can be monitored by PC (in the reception or the technical room). The thermostat is equipped with an ON/OFF input that can be used for applications such as, for instance, detecting an open window or for other general uses. In addi-tion, there is a relay output that can be used to control a generic solenoid valve or as a speed control for a fan-coil. The device is equipped with a display and four front buttons to control the temperature set-point and the speed of the fan-coil.

Technical specifications• supplyvoltage: Bus 30 V d.c. SELV• absorption:10 mA• terminals: - KNX TP Bus - digital input for NO or NC contact (with no potential, SELV) - relay output NO (24 V~ SELV 4 A cos 1; 24 V~ SELV 2 A

cos 0.6)•maximumdistance of the input contact from the device: 30 m

with twisted cable• reading accuracy: ±0.5 °C between 15 °C and 30 °C ±0.8 °C at the extremes• this device contains only SELV circuits that must be kept

separate from circuits with dangerous voltage• operating temperature: -5 °C - +45 °C (for indoor use)

ConfigurationThe configuration of the thermostat, physical address, parameters, its operation, etc., is done with the ETS software.If the thermostat is loaded with an incorrect ETS application, the red LED on the back of the device will flash and all the LCD segments will blink on the display (“device type” error). To restore the desired configuration, load the device with the correct ETS application. With the front buttons, the user can modify the temperature set-point and the speed of the fan-coil; changing these parameters forces the thermostat onto manual operation.

With ETS it is possible to set the following parameters (can be selected directly from the graphic windows): • generalsettings; • temperaturesensor;• temperature setpoint; • setpoint temperature; • input and output;• adjustment;• valve;• fan-coilspeed;• scenes.

OperationUsing the thermostat it is possible to set: •thetemperature set-point in the room (the change can only be

made within certain limits set by the control centre or recep-tion, etc.);

•thespeedof the fan-coil. To change the temperature press the + or - button twice: •on pressing it the first time the display will show the currently

set temperature; •onpressing it the second time the increase/decrease in the

displayed value will begin.

Conformity to StandardsEMC DirectiveStandards EN 50090-2-2, EN 50428

Thermostat display

Room temperature Unit of measurement (Celsius/Fahrenheit)

Air conditioning/Heating

Fan-coil speed

Guest out of room function (Stand-by)

Antifreeze

System off

Operating mode(Manual/Automatic)

Economy

Device locked(cannot be

controlled locally)

ext

THERMOSTAT

OFF

A B C D

Front view and connections

Push-button A: decrease in temperature set-pointPush-button B: increase in temperature set-pointPush-button C: passing from the internal sensor to the thermostat and any

external KNX sensors to display other temperatures Push-button D: increase/decrease in the speed of the fan-coil

Configurationbutton

Input

Commoninput

C

Relay

NO

BUS line

LED

Temperature control - TECHNICAL CHARACTERISTICS

Page 45: Even the most complex building can be simply managed to ...€¦ · Even the most complex building can be simply managed to KNX standard. WELL-CONTACT PLUS. 1 The system to control

43

Control equipment

Side views show the overall dimensions and the flush depth in mm

Temperature control

20451grey

16921grey

16921.Bwhite

14451white

14451.SLSilver

20451.Bwhite

20451.NNext

49

44,837

47,2

49,8

50

36,5

47,8

44,8

49

36

48,3

Electronic thermostatThermostat for ambient temperature control (heating and air-conditioning), KNX standard, 1 relay output NO 4 A 24 V~, 1 digital input - 2 modules

IDEA

PLANA

EIKON

Page 46: Even the most complex building can be simply managed to ...€¦ · Even the most complex building can be simply managed to KNX standard. WELL-CONTACT PLUS. 1 The system to control

44

Control equipment - SPECIFICATIONS

Automation for buildings

01510 - Front view and connections

4 INPUT120/230 V~50/60 Hz

E

Linea Bus

A

B

C

D

01510

IN 1

IN 2

IN 3

IN 4

EIB- +

INPUT

CONF.

L

N

LEDA: LED for state of input 1 B: LED for state of input 2 C: LED for state of input 3 D: LED for state of input 4 E: LED and configuration

button

TERMINALS INPUT 1: digital input 12: digital input 23: digital input 34: digital input 4C: common

01510 - Device with 4 programmable digital inputsThis device enables managing 4 digital inputs for typical applications in the tertiary sector (entry to offices, hospital or hotel rooms, swimming pools, saunas, sports facilities, reserved spaces, etc.). The device is equipped with 4 ON/OFF inputs.

Technical specifications• supply voltage: Bus 30 V d.c. SELV• current absorption: 10 mA• dissipated power: 0,5 W• 4 digital inputs for NO or NC contacts (120/230 V~, 50/60 Hz) • terminals: - TP bus - digital inputs •maximum distance of the input contact from the device: 30 m

with twisted cable • operating temperature: -5 °C - +45 °C (for indoor use)• 2modulesof17.5 mm

ConfigurationThe configuration of the device, physical address and parame-ters (NO or NC contacts inputs, etc.) takes place through the ETS software. If the 4 input device is loaded with an incorrect ETS application, the red LED will flash (“device type” error). To restore the desired configuration, load the device with the correct ETS application.

OperationThe device can be used in two different modes: • functions on a single channel: - ON/OFF switch on the up or down side, toggle on the up

or down side, status send and value send; - call up scenario and save scenario; - counter with 8, 16 and 32 bits;

- management of short/long pressure on a control button; - dimmer control; - roller shutter control;• functions with 2 associated channels: - dimmer control; - roller shutter control.

Conformity to StandardsLV Directive, EMC Directive, Standard 50090-2-2, EN 50428

01523 - Front view and connections

A

B

C

D

EF

linea Bus

OUT 1

OUT 1C C NO C C NO C C NO C C NO

OUT 2 OUT 3 OUT 4

OUT 2

OUT 3

OUT 4

CONF.

EIB

015234 OUTPUT

16A 250V˜

µ

LEDA: LED and button to actuate relay 1 B: LED and button to actuate relay 2 C: LED and button to actuate relay 3 D: LED and button to actuate relay 4 E: LED and configuration button F: button for switching to manual

mode

TERMINALSOUT 1: output relay 1 OUT 2: output relay 2 OUT 3: output relay 3 OUT 4: output relay 4

01523 - Actuator with 4 NO 16 A 250 V~ relay outputsThis device enables managing 4 generic outputs for typical applications in the tertiary sector (entry to offices, hospital or hotel rooms, swimming pools, saunas, sports facilities, reserved spaces, etc.). The device is equipped with 4 relay outputs of 16 A 250 V~ and has manual control for local implementation.The configuration of the device, physical address and parameters (normal or timed relay outputs, logical interlocking of the four relay outputs, etc.) takes place through the ETS software.

Technical specifications• ratedsupply voltage: Bus 30 V d.c. SELV• currentabsorption: 10 mA•dissipated power: 4 W• relayoutputs16 A 250 V~• controllable loads at 250 V~: - resistive loads: 16 A (20,000 cycles) - incandescent lamps: 10 A (20,000 cycles) - fluorescent lamps and energy saving lamps: 1 A

(20,000 cycles) - electronic transformers: 4 A (20,000 cycles) - ferromagnetic transformers: 10 A (20,000 cycles) - motors cos ø 0.6: 3.5 A (100,000 cycles) • terminals: -TP bus - relay contacts (C, NO) • relay configurations: one- and two-position stable • operating temperature: -5 °C - +45 °C (for indoor use) • 4modulesof17.5mm

Conformity to StandardsLV Directive, EMC Directive, Standard 50090-2-2, EN 50428

Automation devices - TECHNICAL CHARACTERISTICS

Page 47: Even the most complex building can be simply managed to ...€¦ · Even the most complex building can be simply managed to KNX standard. WELL-CONTACT PLUS. 1 The system to control

45

Control equipmentAutomation devices

01510

Device with 4 programmable digital inputs 01510 Device with 4 programmable digital inputs for NO, NC contacts, 120-230 V~, KNX standard, installation on DIN rail (60715 TH35),

occupies 2 modules of 17,5 mm

01523

Actuator with 4 NO 16 A 250 V~ relay outputs01523 Actuator with 4 NO 16 A 250 V~ relay outputs, KNX standard, installation on DIN rails (60715 TH35), occupies 4 modules of 17,5 mm

Page 48: Even the most complex building can be simply managed to ...€¦ · Even the most complex building can be simply managed to KNX standard. WELL-CONTACT PLUS. 1 The system to control

46

Control equipment - SPECIFICATIONS

Automation for buildings

01522 - Input/output deviceThis device enables managing 4 inputs and 4 generic outputs for typical applications in the tertiary sector (entry to offices, hospital or hotel rooms, swimming pools, saunas, sports facilities, reserved spaces, etc.). The device is equipped with 4 ON/OFF inputs and 4 relay outputs of 16 A 250 V~ and has manual control for local implementation.

Technical specifications• supplyvoltage: Bus 30 V d.c. SELV• currentabsorption: 10 mA• dissipated power: 4 W• 4 digital inputs for NO or NC contacts (with no potential, SELV)• relayoutputs 16 A 250 V~• controllable loads at 250 V~: - resistive loads: 16 A (20,000 cycles) - incandescent lamps: 10 A (20,000 cycles) - fluorescent lamps and energy saving lamps: 1 A (20,000 cycles); and electronic transformers: 4 A

(20,000 cycles); - ferromagnetic transformers: 10 A (20,000 cycles) - motors cos 0.6: 3.5 A (100,000 cycles)• terminals: - TP bus - relay contacts (C, NO) - digital inputs • relay configurations: one-position stable and two-position stable • operating temperature: -5 °C - +45 °C (for indoor use)• 4 modules of 17.5 mm

Conformity to StandardsLV Directive, EMC DirectiveStandard EN 50090-2-2, EN 50428

01522 - Front view and connections

Linea Bus

A

B

C

D

E

F

G

H

I

L

OUT 1 OUT 2 OUT 3 OUT 4

OUT 1IN 1

IN 1 IN 2 IN 3 IN 4 EIB

IN 2

IN 3

IN 4

OUT 2

OUT 3

OUT 4

CONF.

015224 IN / 4OUT

16A 250V˜

µ

C C NO C C NO C C NO C C NO

LEDA: state of input 1 B: state of input 2 C: state of input 3 D: state of input 4 E: button for switching to manual

mode F: LED and button to actuate relay 1 G: LED and button to actuate relay 2H: LED and button to actuate relay 3 I: LED and button to actuate relay 4L: LED and configuration button

TERMINALS OUT 1: output relay 1OUT 2: output relay 2OUT 3: output relay 3OUT 4: output relay 4IN 1: 1 common and 1 digital input IN 2: 1 common and 1 digital inputIN 3: 1 common and 1 digital inputIN 4: 1 common and 1 digital input

01524 - Front view and connections

LEDA: LED and buttons to actuate relay 1 B: LED and buttons to actuate relay 2 C: LED and configuration button D: button for switching to manual mode

TERMINALSOUT 1: output relay 1 OUT 2: output relay 2

01524BLINDACTUATOR

OUT 1

OUT 2

CONF.

16A 250V˜

µ

EIB

OUT 1C C

OUT 2

BUS line

C C

A

B

CD

01524 - Actuator for two roller shuttersDevice to control 2 roller shutters, motorized sunblinds and Venetian blinds with adjustable slats. The device is equipped with 2 relay outputs of 16 A 250 V~ and has manual control for local implementation.

Technical specifications• rated supply voltage: Bus 30 V d.c. SELV• current absorption: 10 mA• dissipatedpower: 4 W • relayoutputs 16 A 250 V~• controllableloads at 250 V~: - motors cos ø 0.6: 3.5 A (100,000 cycles) • terminals: - TP bus - relay contacts: 2 (, , NO) - : closed if you press the button - : closed if you press the button - C: common• operating temperature: -5 °C - +45 °C (for indoor use)• 4 modules of 17.5 mm

Conformity to StandardsLV Directive, EMC DirectiveStandard EN 50090-2-2, EN 50428

Automation devices - TECHNICAL CHARACTERISTICS

Page 49: Even the most complex building can be simply managed to ...€¦ · Even the most complex building can be simply managed to KNX standard. WELL-CONTACT PLUS. 1 The system to control

47

Control equipmentAutomation devices

01522

Input/output device01522 Input/output device, 4 NO 16 A 250 V~ relay outputs, 4 inputs for NO contacts, KNX standard, installation on DIN rails

(60715 TH35), occupies 4 modules of 17,5 mm

01524

Actuator for two roller shutters01524 Actuator for 2 roller shutters with relay outputs 16 A 250 V~ relay outputs, KNX standard, installation on DIN rails (60715 TH35), occupies

4 modules of 17,5 mm

Page 50: Even the most complex building can be simply managed to ...€¦ · Even the most complex building can be simply managed to KNX standard. WELL-CONTACT PLUS. 1 The system to control

48

Control equipment - SPECIFICATIONS

Automation for buildings

01528 - Dimmer 1-10 VThe dimmer is used to control and adjust the brightness of light circuits via the KNX Bus. The device has 2 independent channels; for each channel there is a ground potential contact to control the power circuits. Together with the light sensor 01530, the appli-ance can be used as a constant brightness dimmer. The dimmer can be connected with up to 2 light sensors. The dimming tel-egrams are converted into 0…10 V signals corresponding to the brightness 0…100%. Art. 01528 works passively, that is the out-puts 1…10 V behave as controlled resistors and the connected electronic ballasts (EVG) provide the current. Except for the KNX Bus voltage, the dimmer requires no external power supply; the rated value for the dimmer can be set separately for each channel or as a MASTER/SLAVE combination.

Technical specifications• supplyvoltage:Bus 30 V d.c. SELV • dissipated power: 250 mW• switchoveroutputs: 2 clean contacts • cut-involtage: 250/440 V~, 50/60 Hz• peakcurrent at cut-in: 400 A (150 μs)/320 A (250 μs)/200 A

(600 μs) • controloutputs: 2, passive 1.... 10 V• connectableload: 100 mA per command output (max 100 m

with 1.5 mm² cable, max 70 m with 0.8 mm² cable) • operating temperature: +5 °C - + 45 °C (for indoor use)• protectionclass IP20• 4modulesof 17,5 mm

Conformity to StandardsLV Directive, EMC DirectiveStandard EN 50090-2-2

01528 - Front view and connections

1: identification plate2: configuration button 3: Red configuration LED4: Bus connection terminals5: operating status and manual

operation ON/OFF 6: power circuit 7: control circuits 1....10 V8: light sensor inputs 015309: light sensor 01530

BALLAST BALLAST

7

6

5

8

9

4

32

1

01530 - Light sensorThe device detects the brightness in the room and, through the connection with the KNX dimmer 01528, keeps the level of brightness in the rooms constant, combining the natural light and the artificial light, thus obtaining the greatest savings and optimizing energy consumptions. It must be installed in a standard box and fixed with a cover using screws.

Technical specifications• inputsforlight sensor 01530: 2 • adjustmentrange: optimized on the typical value of 500 lux

Conformity to StandardsEMC DirectiveStandard EN 50090-2-2

01530 - Assembly diagram

Automation devices - TECHNICAL CHARACTERISTICS

Page 51: Even the most complex building can be simply managed to ...€¦ · Even the most complex building can be simply managed to KNX standard. WELL-CONTACT PLUS. 1 The system to control

49

Control equipmentAutomation devices

Dimmer01528 Dimmer, 2 inputs for 01530, 2 NO 16 A 250 V~ relay outputs, 2 1-10 V outputs, KNX standard, installation on DIN rails (60715 TH35),

occupies 4 modules of 17,5 mm

01528

01530

Light sensor01530 Light sensor for dimmer 01528, ceiling installation

Page 52: Even the most complex building can be simply managed to ...€¦ · Even the most complex building can be simply managed to KNX standard. WELL-CONTACT PLUS. 1 The system to control

50

Control equipment - SPECIFICATIONS

Automation for buildings

01515 - Interface with 4 programmable channelsThe device is equipped with 4 channels that can be configured as inputs or outputs with the ETS software. The connecting cables with pins approximately 30 cm long permit connecting conventional controls, contacts with zero potential and LEDs. The contact interrogation voltage and the supply voltage for the LEDs are available on the device. The additional resistors for the external light emitting diodes are integrated in the same device. The connection to the Bus is made with the terminal block for connection to the Bus.

Technical specifications• ratedsupply voltage: Bus 30 V d.c. SELV• inputs/outputs: 4 configurable as input or output • input: -detection voltage: 20 V pulsating - input current: 0.5 mA • output: - supply voltage: 3-5 V d.c. - output current: max 2 mA limited by additional

resistors • protectionagainst overload and polarity reversal• terminals: - TP bus; - terminal block with 6 connection cables 30  cm

long • protection class: IP20• operatingtemperature: -5 °C - +45 °C (for indoor use)

OperationThe configuration of the device, physical address and parameters takes place through the ETS software.

Conformity to StandardsEMC Directive,EN 50090-2-2 Standards

01515 - Front view and connections

01515

1: Red LED and configuration button2: Inputs/outputs: 6 conductors with pin 3: Bus connection terminals

1 2

3

01526 - Dimmer 230 V~ 50-60 HzThe dimmer is able to control two groups of lamps, each with a maximum power of 300 W. The appliance has two independent output channels; if only one channel is in operation, the connect-ed power increases up to 500 W. Thanks to the low minimum power of 2 W, the dimmer is suited for connecting different types of lamps. Operation is possible of incandescent lamps, 230 V halogen lamps or low-voltage halogen lamps connected to elec-tronic or conventional transformers. The type of load is identified automatically if this is set in the parameters. The two channels are independent and can be connected to different phases and serve different types of load. The configuration of the device, physical address and parameters takes place through the ETS software.

Technical specifications• supplyvoltage: Bus 30 V d.c. SELV • powerconsumption: 4.5 W• outputpower: 300 W/VA (max 500 W if only one channel is

used) •minimum load: 2 W• terminals: - TP bus; - phase 1, neutral, load 1 - phase 2, neutral, load 2• operatingtemperature: -5 °C - + 45 °C (for indoor use)• protection class: IP20• 4 modules of 17.5 mm

Conformity to StandardsLV Directive, EMC Directive Standards EN 50090-2-2, EN 50428

01526 - Front view and connections

1: power supply: possibility of connecting separate phases 2: input/output terminals for connection to the load 3: identification plate 4: Red LED and configuration button5: Bus connection terminals

01526

1

2

3

5

4

Automation devices - TECHNICAL CHARACTERISTICS

Page 53: Even the most complex building can be simply managed to ...€¦ · Even the most complex building can be simply managed to KNX standard. WELL-CONTACT PLUS. 1 The system to control

51

Control equipmentAutomation devices

01515

Interface with 4 programmable channels01515 Interface with 4 channels that can be programmed as inputs or outputs for LEDs, KNX standard

01526

Dimmer 230 V~ 50-60 Hz01526 Dimmer 230 V~ 50-60 Hz for 2x300 W incandescent lamps, 2x300 VA ferromagnetic transformers, 2x300 VA electronic

transformers, KNX standard, installation on DIN rails (60715 TH35), occupies 4 modules of 17,5 mm

Page 54: Even the most complex building can be simply managed to ...€¦ · Even the most complex building can be simply managed to KNX standard. WELL-CONTACT PLUS. 1 The system to control

52

Control equipment - SPECIFICATIONS

Automation for buildings

01500

01500 - Power supply with 30 V d.c. Bus outputPower supply unit for Bus systems equipped with decoupling coil. If there are 30 or more Bus devices installed near to each other (for instance in 10-15 m of cable or in the same electric panel), it is advisable to install the power unit near to these devices.The maximum distance between the power unit and the furthest device must not exceed 350 m. The power unit is self-protected against short circuits (thanks to a voltage and current dimmer) and ensures a power supply even in the event of brief mains failures provided they do not exceed 200 ms.It is recommended to always have a safety switch for the electric power supply circuit of the device 01500.

Technical specifications•supplyvoltage: 230 V~ 50/60 Hz ± 10%•consumption:200 mA max•dissipated power: 4 W•BUS output voltage: 30 V d.c. SELV •total max output current: 320 mA•short-circuit current: 1 A•operating temperature: -5 °C - + 45 °C (for indoor use)•4modulesof 17,5 mm

ConnectionsThe connection to the Bus is made directly from the Bus terminals on the front of the device. The power unit must be installed so that the text is clearly visible and correctly decipherable (Bus polarity reversal). To “Reset” the power unit, remove the Bus

connection terminals and, after approximately 20 seconds, put them back in place. The Bus line is connected to the power supply again and the Bus devices return to their predefined initial conditions.

01501 - Power supply with 30 V d.c. Bus auxiliary outputPower supply unit for Bus systems equipped with decoupling coil. If there are 30 or more Bus devices installed near to each other (for instance in 10-15 m of cable or in the same electric panel), it is advisable to install the power unit near to these de-vices. The maximum distance between the power unit and the furthest device must not exceed 350 m. The power unit is more-over equipped with an auxiliary output that supplies a voltage of 30 V d.c. that can be used to connect an additional Bus line via a decoupling coil. The power unit is self-protected against short circuits (thanks to a voltage and current dimmer) and ensures a power supply even in the event of brief mains failures provided they do not exceed 200 ms.It is recommended to always have a safety switch for the electric power supply circuit of the device 01501.

Technical specifications• supplyvoltage: 230 V~ 50-60 Hz ± 10%.• consumption: 300 mA max• dissipated power: 6 W• BUSoutputvoltage: 30 V d.c. SELV • auxiliary output voltage: 30 V d.c. SELV • totalmaxoutput current: 640 mA• short-circuit current: 1.5 A• operating temperature: -5 °C - +45 °C (for indoor use)• 6 modules of 17,5 mm

01500 - Front view and connections

01501 - Front view and connections

1: ON LED: "normal operation" indicator 2: identification plate 3: power supply terminals: mains 230 V~4: Bus connection terminals

1: ON LED (green): "normal operation" indicator. 2: I >I max LED (red): "overload" or "short-circuit" indicator.3: identification plate 4: Reset LED (red): "device reset" indicator5: Reset button: resets the device6: Bus connection terminals7: terminals for connection to the auxiliary output: 30 V d.c. 8: power supply terminals: mains 230 V~

3

1 2

4

01501

1

7

8

3

4

6

5

2

System Devices - TECHNICAL CHARACTERISTICS

Page 55: Even the most complex building can be simply managed to ...€¦ · Even the most complex building can be simply managed to KNX standard. WELL-CONTACT PLUS. 1 The system to control

53

Control equipmentSystem devices

01500

01501

Power supply with 30 V d.c. Bus output01500 Power supply with 30 V d.c. 320 mA Bus output, power supply 120-230 V~ 50-60 Hz, with decoupling coil, KNX standard,

installation on DIN rail (60715 TH35), occupies 4 modules of 17,5 mm

Power supply with 30 V d.c. Bus auxiliary output01501 Power supply with 30 V d.c. 640 mA Bus output, auxiliary output 30 V d.c., power supply 230 V~ 50/60 Hz, with decoupling coil,

KNX standard, installation on DIN rail (60715 TH35), occupies 6 modules of 17,5 mm

Page 56: Even the most complex building can be simply managed to ...€¦ · Even the most complex building can be simply managed to KNX standard. WELL-CONTACT PLUS. 1 The system to control

54

Control equipment - SPECIFICATIONS

Automation for buildings

01504 - Front view and connections 01504 - Line couplerThis device permits connecting a number of Bus lines together in order to share and/or transfer the data messages; in addition, it provides electrical separation between the lines and filtering of unnecessary messages. The device manages filter tables that are used to block or let messages pass between the various lines limiting and optimizing the data traffic; these tables are created automatically by the ETS software.The line/field coupler can be used irrespectively as a line cou-pler, field coupler or repeater for all KNX networks.

Technical specifications• supplyvoltage: 30 V d.c. SELV Note: The device must be powered on both sides• currentabsorption: 10 mA• operating temperature: +5 °C - +45 °C (for indoor use)• 2modulesof17,5 mm

Conformity to StandardsEMC DirectiveEN 50090-2-2 Standards

1: ON LED: "normal operation" indicator 2: Main Line LED: data transit on the main line3: Line LED: data transit on the secondary line4: terminals for connection to the bus of the main line5: terminals for connection to the bus of the secondary line6: Configuration LED 7: Configuration button: button for switching between normal mode or

programming mode or detecting the physical address8: identification plate

01504

123

5 4

8

67

01540 - B-type USB interfaceThis device is used, via the built-in USB port, to connect a per-sonal computer to the Bus line (or Bus lines) to configure, ad-dress, parameterize, display, record and diagnose all the com-ponents of the bus system. The interface is connected to the PC via the USB port (B-type) built into the device and any USB port (A-type) of the personal computer or of a HUB. The inter-face is powered by the PC over the USB cable; if this is not con-nected or the personal computer is switched off, the interface is not active and cannot be accessed by the Bus.In addition, the USB interface enables connecting the recep-tion PC for the complete supervision and management of the system with the Well-contact Suite software.

Note.The USB cable (A-type on the PC side and B-type on the inter-face side) is not provided.

Technical specifications• supply voltage: Bus 30 V d.c. SELV• consumption: 10 mA• operating temperature: -5 °C - + 45 °C (for indoor use)• 2modulesof17,5 mm

Conformity to StandardsEMC DirectiveStandard EN 50090-2-2

1. identification plate 2. configuration button: button for switching between normal mode or

programming mode or detecting the physical address 3. Configuration LED 4. Bus connection terminals 5. USB LED: data transmission/reception on the USB port 6. KNX LED: data transmission/reception on the Bus 7. USB port

INDICATORSLED 3 on red: “addressing mode” indicator (the LED goes out automatically after programming the physical address)LED 3 off: "normal operation" indicatorUSB LED on green: "USB connection made" indicatorKNX LED blinking green: “data in transit on bus line” indicator

01540 - Front view and connections

°°

01540

7

65

2

1

3

4

16887 - Transformer for DIN rail (60715 TH35) Transformer in a modular enclosure (3 modules of 17,5 mm) for DIN rail (60715 TH35).

Technical specifications• power supply: 230 V~ 50 Hz•maximumusable power on output 24 V~: 24 VA•maximum usable power on output 12 V~: 12 VA• canbeinstalled on DIN rail (60715 TH35)• 3 modules of 17,5 mm

Conformity to StandardsLV DirectiveStandard 61558-2-8

System devices - TECHNICAL CHARACTERISTICS

Page 57: Even the most complex building can be simply managed to ...€¦ · Even the most complex building can be simply managed to KNX standard. WELL-CONTACT PLUS. 1 The system to control

55

Control equipment

Line coupler01504 Line coupler, KNX standard, installation on DIN rail (60715 TH35), occupies 2 modules of 17.5 mm

System devices

B-type USB interface01540 B-type USB interface, KNX standard, installation on DIN rail (60715 TH35), occupies 2 modules of 17,5 mm

01540

Safety transformer16887 Safety transformer 230/12-24 V~ (SELV) 24 VA, for continuous service, installation on DIN (60715 TH35) rail, occupies 3 modules

of 17.5 mm, RAL 7035 grey

16887

01890

Bus cable 01890 Cable 2x2x0.8 mm, LSZH halogens-free, KNX standard, green - 100 m

01504

Page 58: Even the most complex building can be simply managed to ...€¦ · Even the most complex building can be simply managed to KNX standard. WELL-CONTACT PLUS. 1 The system to control

56

Control equipment - SPECIFICATIONS

Automation for buildings

Well-contact Suite Software (WCS)To manage and supervise the Well-contact Plus system, Vimar has created a family of software products to try and satisfy the requests of the different types of systems of its customers. The following table lists the six types of application.

Basic: to manage a structure with up to 50 rooms from a single station. Thanks to 5 password levels, control can be customized: the manager of the structure, for example, can access the complete system to supervise, edit the parameters and program the functions, while the receptionist with another password will only access some of these operations.

Top: to control large hotel structures with a potentially limitless number of rooms and stations. This application has 7 password levels and makes it possible to use the planner for supervising arrivals and departures.

Client: application licence enabling you to manage the Basic and Top systems from a limitless number of stations.

Office: dedicated to offices and business structures, it enables managing the functions of a potentially limitless number of rooms from one station. With 7 password levels, control can be targeted and secure.

Client Office: Office application licence enabling access to the program from any number of stations.

Management: for interfacing with administration management software

ApplicationsThe WCS software is used to carry out the following operations:•managementofbookings (hotel version);•managementof the user records; •management of structure personnel records;•managementof access by users and personnel to the various

rooms in the structure: creation of the cards for the access control system, management of the transponder readers of the part of the system that deals with access control, creation of lists with access log;

• supervision of the automation system: climate control, activation of electric loads (lights on/off, dimmer lights, relays), access control management, alarm management, creation of scenes, scheduling activation of scenes, reaction of decisional logic elements.

As regards managing security when using the Well-contact Suite software, the strategies implemented in the software are listed here: • access to the software allowed only for users previously

configured in the software; • seven levelsofsoftware access “privileges” to be associated

with the software users;• encrypted data communication between the system file server

and client systems; • encrypted “sensitive” data (e.g. software user password);• encrypted data communication between the system and the

card programmer;• useofMifare® Standard cards.

The main characteristic of the Well-contact Suite software is to automatically create graphic windows in the supervision section. These windows show all the rooms in the hospitality facility with graphic symbols representing the main functions of the automation system devices in the rooms. The rooms are divided according to their use: rooms, common areas, technical areas. For each type of room there are one or more of the following “theme views.” A theme view is a representation of the room highlighting a particular function of the devices in the room. The “theme views” envisaged in the Well-contact Suite software comprise: • the“thermostats”view;• the“Guestin room” view;• the“windows opening status” view;• the“roomcleaning status” view.

Besides the theme views, a “summary view” is created automatically, in which the room’s main data are shown.

Besides the above-mentioned views, the Well-contact Suite software automatically creates a window with the “detail” view of the room, in which the graphic symbols of the room’s main functions are included; the type of functions automatically presented in the detail view of the room and the related characteristics can be customized according to the particular requirements of the user. In any case, the supervision windows created automatically by the Well-contact Suite software can be customized to collect the user’s requests.

The Well-contact Suite software enables viewing the alarm events created by the Well-contact Plus system to send an alarm “reset” command to the system and create a log for these events. It is lastly possible to define different types of alarm together with the related display priorities.

WCS Gestionali WCS Office Client WCS Office WCS Client WCS Top WCS Basic

WCS Gestionali WCS Office Client WCS Office WCS Client WCS Top WCS Basic

WCS Gestionali WCS Office Client WCS Office WCS Client WCS Top WCS Basic

WCS Gestionali WCS Office Client WCS Office WCS Client WCS Top WCS Basic

WCS Gestionali WCS Office Client WCS Office WCS Client WCS Top WCS Basic

WCS Gestionali WCS Office Client WCS Office WCS Client WCS Top WCS Basic

Zone supervision screen

Well-contact Suite software - TECHNICAL CHARACTERISTICS

Page 59: Even the most complex building can be simply managed to ...€¦ · Even the most complex building can be simply managed to KNX standard. WELL-CONTACT PLUS. 1 The system to control

57

Control equipmentWell-contact Suite software

01597

Well-contact Suite software 01590 Well-contact Suite Basic software for managing and controlling the Well-contact Plus devices, complete with CD and hardware key

01591 As above, Well-contact Suite Top

01592 As above, Well-contact Suite Client

01593 As above, Well-contact Suite Office

01594 As above, Well-contact Suite Client Office

Supplementary Well-contact Suite software for administration management 01595 Supplementary Well-contact Suite software for interfacing with administration management software

(for an up-to-date list of the supported management software, please contact the sales network)

Spare USB key for Well-contact Suite 01597 Spare USB key for Well-contact Suite software

0159001591015920159301594

01595

To order in the event of breakage or malfunctioning of the USB hardware key contained in the package of the articles 01590, 01591, 01592, 01593, 01594.

Please, contact the commercial network for further information

Page 60: Even the most complex building can be simply managed to ...€¦ · Even the most complex building can be simply managed to KNX standard. WELL-CONTACT PLUS. 1 The system to control

58

Control equipment - SPECIFICATIONS

Automation for buildings

01998.U - EasyTool software and touch screen configurerThe package includes the EasyTool software for configuring the devices of the By-me home automation system and the configurer software for programming the touch screens 20848, 14848, 20849, 16849 and 14849.

The interface, equipped with a USB driver, must be connected to a PC on which the EasyTool or touch screen configurer management software must be installed.

The main operations that can be performed with the touch screen configurer application are the following:•importfromETS file of one or more systems;•updateof the touch screen firmware;•touchscreen configuration.

Alternatively to article 01998.U, it is possible to use the interface 01998.S downloading the touch screen configurer software from the website www.vimar.eu.

Technical specifications•The touch screen configurer software is compatible with the

following operating systems:- Microsoft Windows: 2k, XP, Vista and 7 (32 bit)•power supply directly from PC via USB port•USB cable with A-type connector for PC connection,

1.8 metres long (supplied)•cablecustomized and polarized for connecting programming

device, length of cable 1.50 m (supplied)•operatingtemperature: +5 °C - +40 °C•dimensions:115x75x25 mm

OperationThe ON LED comes on when the interface is connected to the computer via the USB cable. During the transmission/reception of the data, the LEDs h and i light up as follows:• LEDh on when the PC receives the data from the specific

device;• LEDi on when the PC transmits the data to the specific

device.

Conformity to StandardsEMC DirectiveStandards EN 55022, EN 55024

01998.U - Front view

ON

USB connector for connecting to the PC

RJ11 connector for connecting to the touch screen

Connecting the PC to the touch screens

8-module touch screen

3-module touch screen

Software and interface - TECHNICAL CHARACTERISTICS

Page 61: Even the most complex building can be simply managed to ...€¦ · Even the most complex building can be simply managed to KNX standard. WELL-CONTACT PLUS. 1 The system to control

59

Control equipmentSoftware and interface

EasyTool software and touch screen configurer01998.U EasyTool software and touch screen configurer for Well-contact Plus complete with USB interface

Touch screen configurer software screens

01998.U

Screen example of 3-module touch configurationScreen example of 8-module touch configuration

Page 62: Even the most complex building can be simply managed to ...€¦ · Even the most complex building can be simply managed to KNX standard. WELL-CONTACT PLUS. 1 The system to control

60

Control equipment - SPECIFICATIONS

Automation for buildings

The following examples give some types of hotel and tertiary sector systems; depending on the functions to be implemented, it is necessary to choose not only the devices but above all how these must be configured.

In the case of a hotel room the guest, by putting the card into the transponder reader, enters the room; the device, after recognizing the card, activates the main light in the room and the bed-head courtesy light (example of a scene) that then will also be able to be commanded by the single buttons. Subsequently the guest inserts the card into the pocket reader; lastly, when the guest leaves the room, he takes out the card and, after a set time, all the loads are switched off. In the room and the suite in the examples, different functions have been implemented according to the required level of comfort.

Room Required functions: check-in /check-out.Room status indicators on the external transponder reader:•Guestinroom;•Roomoccupiedor “do not disturb”;• Room to make up;•Card recognition indicator;5 input indicators: wc/bathroom call, room service call, win-dow contact, “do not disturb”, room main light control. 5 output relays: electrical lock opening, courtesy light, load disconnection, room main light, climate control ON/OFF sole-noid valve command.3 necessary components: external transponder card reader, internal transponder pocket reader, electronic thermostat.

16927.BTransponder card reader

for outside room

16923.BTransponder card reader

for inside room

16921.BThermostat

16840.B + (2) 16841.B+ 16841.2.B + 16843.B4-indipendent push button

01820Magnetic contact

16083.BCord-operated push button

Automation for the hotel sector

Installation examples

Page 63: Even the most complex building can be simply managed to ...€¦ · Even the most complex building can be simply managed to KNX standard. WELL-CONTACT PLUS. 1 The system to control

61

Control equipmentAutomation for the hotel sector

Connection diagram

SV

230 V~

Pull-cordbathroom

Load discon-nection(230 V~)

Call button room service

Room main light(230 V~)

Courtesy light(230 V~)

Electric lock

Do not disturb button

Lights button mainroom

Contactwindow01820

12-24 V~

(12-24 V~)~

16921.B

16927.B 16923.B

16840.B + (2)16841.B+ 16841.2.B + 16843.B

KNX Bus

KNX Bus

KNX Bus

0154001501

Reception

20450

230 V~

Page 64: Even the most complex building can be simply managed to ...€¦ · Even the most complex building can be simply managed to KNX standard. WELL-CONTACT PLUS. 1 The system to control

62

Control equipment - SPECIFICATIONS

Automation for buildings

9 output relays: electrical lock opening, courtesy light, bedside light, load disconnection, “guest in room” message, 3-speed fan coil control, room main light. 4 necessary components: external transponder card reader, internal transponder pocket reader, electronic thermostat, input/output device. Touch screen: control of lights, air-conditioning and scenes in bedroom, bathroom and lounge.

Suite Required functions: check-in /check-out.Room status indicators on the external transponder reader: •Guest in room;•Room occupied or DO NOT DISTURB;•Roomtomake up; •Cardrecognition indicator;9 input indicators: WC/bathroom call, reset room service call, window contact, “do not disturb”, fridge-bar indicator, room service call, door open indicator, room main light control, 1 spare input.

01522Input/output device

20457Transponder card reader outside room

20453Transponder card reader inside room

20451Thermostat

3 x 200081P NO push button

208493-module

touch screen

208493-module

touch screen

20053Cord-operated push button

01820Window contact

Installation examples Automation for the hotel sector

Page 65: Even the most complex building can be simply managed to ...€¦ · Even the most complex building can be simply managed to KNX standard. WELL-CONTACT PLUS. 1 The system to control

63

Control equipment

Connection diagram

230 V~Bathroom ceiling pull-cord

Load discon-nection(230 V~)

Room service call reset button

Courtesy light (230 V~)

Electric lock

Fridge-bar indicator

Door open in-dicator 01820

Room service call button

Room main light (230 V~)

Do not disturb button

Room main light button Window

contact 01820

Bedside table light (230 V~)

Fan-coil

12-24 V~

KNX Bus

KNX Bus

KNX Bus

20457 20453 20451

015222084920849

230 V~

L

N

M

Automation for the hotel sector

0154001501

Reception

20450

230 V~

Page 66: Even the most complex building can be simply managed to ...€¦ · Even the most complex building can be simply managed to KNX standard. WELL-CONTACT PLUS. 1 The system to control

64

Control equipment - SPECIFICATIONS

Automation for buildings

adjusted via the brightness sensor 01530 connected to the dimmer by DIN rail 01528. The thermostat directly controls the solenoid valve for the heating/air-conditioning system besides turning it off if there is an open window (magnetic contact connected to the thermostat input). Finally, all the accesses made (guest, time, duration, etc.) and any alarms or faults will be monitored by the PC in the reception via the Well-contact Office Suite software.

Hotel ground floorThe example in the figure illustrates entry and automation device management via the Well-contact Plus system with the KNX standard. By means of the transponder reader, entry to the rooms will be allowed only for cleared users; the control of the lights and roller shutters is performed using the 4 independent push buttons appropriately combined with their respective button caps.In the conference room, the lights are adjusted with a 4 independent push buttons combined with two double button caps, while in the reception the lighting is automatically

20840+ (2) 20841.0+ (2) 20841.24-independentpush button

01501; 01504;01523; 01524;01526; 01528Supply unit, line coupler, actuator, dimmers

20840+ (2) 20841.2+ (2) 20841.04-independentpush button

20840+ 20842.34-independentpush button

01530Light sensor

20451Thermostat

01540B-type USB

interface

20450Transponder card reader in table box

20840+ (2) 20842.4

4-independent push button

20840+ (2) 20842.34-independent push button

20457Transponder card

reader outside room

20848 + 20788 8-module

touch screen

RECEPTION

CONFERENCE ROOM

STORE OFFICES

TECH. ROOM

BAR

Installation examplesAutomation for the hotel sector

Page 67: Even the most complex building can be simply managed to ...€¦ · Even the most complex building can be simply managed to KNX standard. WELL-CONTACT PLUS. 1 The system to control

65

Control equipment

230 V~

230 V~

12 - 24 V~

LL2

L

N

L3 N

01523

01504

0152801530

01500

01501

01526

01540

01524

20840 + (2) 20841.0 + (2) 20841.2

20840 + (2) 20841.0 + (2) 20841.2

20840 + 20841.3

20840 + 20841.4

230 V~

Light 1Offices

Light 2Offices

Light 1Bar

Light 2Bar

Roller shutterConference room

Roller shutterReception

KNX Bus

KNX Bus

KNX Bus

SV

230 V~Window contact

01820

20451

Light n* Light n*

* Offices, Conference room, Store, Technical room

Light n* Light n*

20457 20457 20457 20457

Electric lock Electric lock Electric lock Electric lock

Conference room light

LightReception

BALLAST

0-10 V LN

20450

Connection diagram

MM

V+

V+

V-

V-

30 V

20848 + 20788

Automation for the hotel sector

Reception

Page 68: Even the most complex building can be simply managed to ...€¦ · Even the most complex building can be simply managed to KNX standard. WELL-CONTACT PLUS. 1 The system to control

66

Control equipment - SPECIFICATIONS

Automation for buildings

In particular, it will be possible to differentiate different solutions for the common areas in order to manage the services offered to guests in a differentiated manner. By using the dedicated transponder reader it will be possible to control access to particular services such as for instance the swimming pool, sauna, spa and car parks, with the possibility of accounting them thanks to the interfacing between the Well-contact Suite management/supervision software and the management/administration software. The lights and roller shutters are managed with the 4-button controls or the touch screen. The methods of managing the temperature for the Halls or for the common areas will be set at the time of programming; using the thermostat connected directly to the Bus will enable measuring the temperature in a certain area and, with the output on the thermostat, you can control the solenoid valve or the fan convectors for the heating and air-conditioning.

Hotel common areas Managing the common areas in hotel structures is extremely important both because it allows complete supervision along with flexible convenient use of all the services provided by the structure and because from a commercial point of view it has a considerable impact on the guest. Checking entries, allowing entry only for authorized vehicles or, in places not normally manned, activating lights and generic controls and receiving any type of signalling increases the value perceived by the guest and at the same time offers advantages for the management personnel from an operational point of view. Using the new devices integrated in the Well-contact Plus system with the KNX standard, it is possible to manage all the environments, fully optimizing the work of the personnel and contributing significantly to the safety and control of the whole building.

SOLARIUM

TURKISH BATH

SAUNA

GYM

20457.BTransponder card reader outside room

20840 + 20482.4.B4-independent push button

01522; 01501; 01523; 01526; 01540Input/output device;supply unit; activator; dimmer; USB interface 20840 + 20842.3.B

4-independent push button

20850.BIR presence

detector

20451.BThermostat

20840 + 20842.3.B4-independent push button

20840 + 20842.4.B 4-independent

push button

Installation examplesAutomation for the hotel sector

Page 69: Even the most complex building can be simply managed to ...€¦ · Even the most complex building can be simply managed to KNX standard. WELL-CONTACT PLUS. 1 The system to control

67

Control equipment

Connection diagram

20840 + 20842.3.B

20840 + 20842.3.B

20850.B 20850.B 20840 + 20842.4.B

0154001501

20450.B

12 - 24 V~

SV

230 V~

20451.B

Light n*

Electric lock

20457.B

230 V~

L1

NL2

Lightmassages

LightTurkish bath

01526 01524 01522

M M

Roller shutter Swimming pool

LightToilet

LightGarage

Roller shutterGym

230 V~

* Swimming pool, Sauna, Solarium, Turkish Bath, Gym, Garage, Massage room, Locker room

KNX Bus

KNX Bus

KNX Bus

Automation for the hotel sector

Reception

Page 70: Even the most complex building can be simply managed to ...€¦ · Even the most complex building can be simply managed to KNX standard. WELL-CONTACT PLUS. 1 The system to control

68

Control equipment - SPECIFICATIONS

Automation for buildings

they are installed; the colour touch screen installed in the meeting room enables controlling the lights, roller shutters, temperature and scenes of the entire system. The lights and roller shutters in the reception and in the technical room are instead managed by the 4 independent push button controls combined with the respective button caps identifying the controlled service; the infrared sensors installed in the bathroom switch the lighting on for a set time only when they detect the presence of one or more people in order to optimize energy consumption.Finally, all the accesses made (employee, time, etc.) and any alarms or faults will be monitored and saved by the PC in the reception via the Well-contact Office Suite software.

Offices The example in the figure illustrates the use of the Well-contact Plus devices with the KNX standard in the typically tertiary sector in which there is the need to manage diversified accesses to the various offices/rooms while monitoring it all from the PC in the reception; the control of the lights and roller shutters is performed using the 4-button controls and the touch screens. By means of the transponder reader, entry to the offices and technical room will be allowed only for cleared users; the personnel manager will have access to all the areas 24 hours a day every day of the week while employees can only enter their own office and only on business days. The 3-module flush mounting touch screens enable managing the lights, roller shutters and any scenes for the office in which

14450Transponder card

reader in table box

14840 + 14841.0 + 14841.1 + (2) 14841.34-independent push button

01501; 01523; (3) 01524Supply unit; actuators

14840 + 14842.0 + 14842.14-independent push button

148488-module touch screen

148493-module touch screen

(4) 14850IR presence detector

(3) 14457Transponder card reader outside room

14840 + 14841.0 + 14841.1 + (2) 14841.3

4-independent push button

148493-module

touch screen

14451Thermostat

01540USB interface

Installation examplesAutomation for the tertiary sector

Page 71: Even the most complex building can be simply managed to ...€¦ · Even the most complex building can be simply managed to KNX standard. WELL-CONTACT PLUS. 1 The system to control

69

Control equipment

Connection diagram

14840 + 14841.0+ 14841.1+ (2) 14841.3

14840 + 14841.0+ 14841.1+ (2) 14841.3

14850 14850 14849 14849

14848

14840 + 14842.0+ 14842.1

0154001501

14450

12 - 24 V~

SV

230 V~

14451

Light n*

Electric lock

14457

230 V~

L

N

01524 01524 01524

M M MM M M

Roller shutterReception

Roller shutter 1 Meeting room

Roller shutterTech. room

V+ V-

30 V

01523

Light 1Bathroom

LightReception

Light 2Bathroom

Roller shutterOffice 1

Roller shutterMeeting room

Roller shutterOffice 2

230 V~

* Corridor, Office 1, Meeting room, Technical room, Office 2

KNX Bus

KNX Bus

KNX Bus

Automation for the tertiary sector

Reception

Page 72: Even the most complex building can be simply managed to ...€¦ · Even the most complex building can be simply managed to KNX standard. WELL-CONTACT PLUS. 1 The system to control
Page 73: Even the most complex building can be simply managed to ...€¦ · Even the most complex building can be simply managed to KNX standard. WELL-CONTACT PLUS. 1 The system to control
Page 74: Even the most complex building can be simply managed to ...€¦ · Even the most complex building can be simply managed to KNX standard. WELL-CONTACT PLUS. 1 The system to control
Page 75: Even the most complex building can be simply managed to ...€¦ · Even the most complex building can be simply managed to KNX standard. WELL-CONTACT PLUS. 1 The system to control

Vimar reserves the right to modify its products at any time without advance notification.Due to layout considerations, the images and drawings of the products are not in scale to each other.

Page 76: Even the most complex building can be simply managed to ...€¦ · Even the most complex building can be simply managed to KNX standard. WELL-CONTACT PLUS. 1 The system to control

B.C11021 EN 1103Viale Vicenza, 14

36063 Marostica VI - ItalyTel. +39 0424 488 600Fax +39 0424 488 709

www.vimar.eu