Upload
vannguyet
View
229
Download
6
Embed Size (px)
Citation preview
BRUSA Elektronik AGNeudorf 14CH-9466 Sennwald+41 81 758 19 00 [email protected]
EVB1 - HV-Battery (16kWh/400V or 14kWh/350V)Compact high-performance
Safety fi rst
• Integrated battery-management-system (BMS)
• Fast measurement and monitoring of all cell-voltages / temperatures
• Automatic derating at overtemperature
• Integrated fuse
• Ah counter with DoD-management and SoH-management (State of Health)
• Integrated Loading device with short-circuit detection
Cutting-Edge Technology
• CAN-Bus controlled
• Integrated charger control (NLG5)
• Simply and fast installation / commissioning
• Compact and lightweight design
• Very high performance and energy density (1,1 kW/kg and 110 Wh/kg)
• Watercooled for best Performance
• Automatic cell-Balancing (passive)
• Parallel connection of several EVB1 possible
• For automotive and industrial applications in high-performance range (Mid-size cars, sports cars, racing, hybrids, trucks, buses, boats etc.)
• More than 500.000 km field testing with own prototypes
Dimensions EVB1-400-40 Dimensions EVB1-350-40
BO
TTO
M
BO
TTO
M
BRUSA Elektronik AGNeudorf 14CH-9466 Sennwald+41 81 758 19 00 [email protected] www.brusa.biz
Specifi cations EVB1 Electrical data EVB1-400-40 EVB1-350-40Battery confi guration 1P108S 1P96S ---
Number of cells 108 96 ---
Capacity (per Cell) 40 40 Ah
Energy content 16 14 kWh
Technology Li-Ion Li-Ion ---
Nominal voltage 400 350 V
Max. Voltage 448 400 V
Min. Voltage 324 290 V
Discharge cont. 200 (80) 200 (70) A(kW)
Discharge peak (default derating) 400 (160) 400 (140) A(kW)
Max. Charging current 80 (32) 80 (28) A(kW)
Internal resistance at 25°C 130-150 120-140 mΩ
Internal fuse protection 400 400 A
Control CAN-Bus (500k/1Mbit) CAN-Bus (500k/1Mbit) ---
Power consumption offl ine / Standby (per Cell) 40 40 uA
BMS-Power consumption at internal fan power = 100% (Kl. 30 = 12V) 3.6 3.6 A
BMS-Power consumption at internal fan power = 0% (Kl. 30 = 12V ) 0.75 0.75 A
Mechanical data / Cooling system EVB1-400-40 EVB1-350-40Coolant quantity in device approx. 450 approx. 400 ml
Recommended coolant temperature at the inlet +5 to +20 +5 to +20 °C
Min. Coolant temperature at the inlet 0 0 °C
Max. Coolant temperature at the inlet < +40 < +40 °C
Temperature range charge +10 to +45 +10 to +45 °C
Temperature range discharge -10 to +55 -10 to +55 °C
Coolant medium pressure loss @ 6l/min, Tcoolant = 25°C (water/glycol = 50/50) 66 60 mbar
Maximum pressure of coolant medium 1.0 1.0 bar
System weight (without coolant medium) approx. 145 approx. 130 kg
IP-protetion IP65 IP65 ---
Performance of water cooler approx. 1000 approx. 900 W
BR
USA
/ 10
.20
13 /
EV
B1
EVB1-400-40 Discharge with 400 A (160 kW)
Optional we recommend using the following products:
• Isolation guard ISO1-500-50• PDU254 with Interlock generator
EVB1-400-40 Discharge with 200 A (80 kW)
Safety concept