세일국제무역 Tel. 02-837-6974 · Fax. 02-859-2059 · e-mail : [email protected] · homepage : www.rbr.co.kr 1/2 ADVANTAGES OF USING A LASER LIGHT SOURCE • Measuring path up to 20 meters possible, due to a narrow and intense laser light beam. • Excellent beam collimation (0,04 °) no need to use lenses or mirrors in the transmitter making the system reliable and simple • Standard wavelength guarantees longterm accuracy and stability • The analyser can be transferred to another location without factory calibration. • The alignment of the beam is easy because the beam is narrow PRINCIPLE OF OPERATION The measuring system is based on the single pass principle. The light beam crosses the measuring section once only and the receiver unit measures and evaluates the light beam’s weakening caused by the dust content. The optical value will be shown as opacity % on analogue display and digital display. Manualcalibration check can be done by using optical filter. FEATURES OF THE MONITOR UNIT • 4 operator selectable measuring ranges • Analogue and digital display • Settable alarm relay • 0 ... 1 V DC and 4 … 20 mA current outputs TYPICAL APPLICATION • Powerplants • Cement factories • Incinerators • Tunnels • Minimum optics needed less maintenance • Optimal for stacks up to 20 meters • No moving partsminimal maintenance • Large operation range ( 0 ... 90 %) • Good stability and reliability LASER LIGHT SOURCEULTIMATE WAWELENGHT STABILITY, EXCELLENT COLLIMATION AND HIGH SENSITIVITY LASER LIGHT SOURCEULTIMATE WAWELENGHT STABILITY, EXCELLENT COLLIMATION AND HIGH SENSITIVITY ETG DUST MONITOR MODEL 3188

ETG DUST MONITOR MODEL 3188 › ETG_Dust_Monitor3188.pdf · 2019-03-06 · ETG DUST MONITOR MODEL 3188 Detection Power Ambient temperature Purge flow requirement Dimensions Optically

  • Upload
    others

  • View
    9

  • Download
    0

Embed Size (px)

Citation preview

Page 1: ETG DUST MONITOR MODEL 3188 › ETG_Dust_Monitor3188.pdf · 2019-03-06 · ETG DUST MONITOR MODEL 3188 Detection Power Ambient temperature Purge flow requirement Dimensions Optically

세일국제무역 Tel. 02-837-6974 · Fax. 02-859-2059 · e-mail : [email protected] · homepage : www.rbr.co.kr 1/2

ADVANTAGES OF USING A LASERLIGHT SOURCE

• Measuring path up to 20 meterspossible, due to a narrow and intenselaser light beam.

• Excellent beam collimation (0,04 °) ‐no need to use lenses or mirrors in thetransmitter making the system reliableand simple

• Standard wavelength guarantees longtermaccuracy and stability

• The analyser can be transferred toanother location without factorycalibration.

• The alignment of the beam is easybecause the beam is narrow

PRINCIPLE OF OPERATION

The measuring system is based on the single passprinciple. The light beam crosses the measuring sectiononce only and the receiver unit measures and evaluatesthe light beam’s weakening caused by the dust content.The optical value will be shown as opacity % on analoguedisplay and digital display. Manual‐calibration check can bedone by using optical filter.

FEATURES OF THE MONITOR UNIT

• 4 operator selectable measuring ranges• Analogue and digital display• Settable alarm relay• 0 ... 1 V DC and 4 … 20 mA current outputs

TYPICAL APPLICATION

• Powerplants• Cement factories• Incinerators• Tunnels

• Minimum optics needed ‐ less maintenance• Optimal for stacks up to 20 meters• No moving parts‐minimal maintenance• Large operation range ( 0 ... 90 %)• Good stability and reliability

LASER LIGHT SOURCE‐ULTIMATE WAWELENGHT STABILITY, EXCELLENT COLLIMATION AND HIGH SENSITIVITYLASER LIGHT SOURCE‐ULTIMATE WAWELENGHT STABILITY, EXCELLENT COLLIMATION AND HIGH SENSITIVITY

ETG DUST MONITOR MODEL 3188

Page 2: ETG DUST MONITOR MODEL 3188 › ETG_Dust_Monitor3188.pdf · 2019-03-06 · ETG DUST MONITOR MODEL 3188 Detection Power Ambient temperature Purge flow requirement Dimensions Optically

세일국제무역 Tel. 02-837-6974 · Fax. 02-859-2059 · e-mail : [email protected] · homepage : www.rbr.co.kr 2/2

RECEIVER UNIT

Light typeWavelenghtAmbient temperaturePurge flow requirementDimensions

Semicond laser655 mm, visible light‐20 ... +60° CMin. 10l/min25 x 80 x 145 mm, weight 1,0 kg

TRANSMITTER

CommunicationDisplay

ControlsAlarms and mode indicatorsOutputs/Inputs

EnvironmentalDimensions

Analogue, Windows‐base monitoring software as option availableAnalog display for optical density, 0 ... 100 % linear scale Digital display, 3‐digitLCD for mg/m3Range switch, calibration and alarm settingsRelay 115 or 230 VAC, 1A max, with led indicatorCurrent 4 ... 20 mA for real‐time D‐value/mg/m3 Voltage 0 ... 1 V DC for realtimetime D‐value/mg/m3Ambient temperature 0 ... 70° C, Power 115/230 VAC, 14 VASize: 180 x 215 x 130 mm, weight 1,5 kg

MONITOR UNIT

Range switch

Position

1234Option:(* Depends on the size and density of the particles, values given with the size of ave. 1 μm and 1 kg/dm³)

D‐value

0...0.030...0.10...0.30...1.00...3.0

Opacity %

0...6.70...200...500...900...99

Massrange *)mg/m³Dist. 1 mt

0...240...800...2400...8000...2400

Massrange *)mg/m³Dist. 2,5 mt

0...9,60...320...960...3200...960

Massrange *)mg/m³Dist. 5 mt

0...4,80...160...480...1600...480

MEASUREMENT FUNCTIONS AND RANGES

LASER LIGHT SOURCE‐ULTIMATE WAWELENGHT STABILITY, EXCELLENT COLLIMATION AND HIGH SENSITIVITY

ETG DUST MONITOR MODEL 3188

Detection

PowerAmbient temperaturePurge flow requirementDimensions

Optically matchedsemicond. detector, Ø50 mmFrom monitor unit‐20 +80°CMin. 30l/min170 x 110 x 125 mm,weight 1,25 kg