9
Establish/Maintain a Portal and Distributed Relay [email protected] IEEE 802 plenary, San Antonio, November 2012 1

Establish/Maintain a Portal and Distributed Relay

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Establish/Maintain a Portal and Distributed Relay

[email protected]

IEEE 802 plenary, San Antonio, November 2012

1

Agenda

• Initialize a Portal

• Monitor the function port

• Monitor the IPL /Portal System

IEEE 802 plenary, San Antonio, November 2012

2

Initialize a Portal

IEEE 802 plenary, San Antonio, November 2012

3

• Each Portal System configure parameters to it’s “local” managed objects.(6.4)

• Enable DRCP to start Portal System’s DRNI ability notification to each Portal Systems among the Portal

• Portal Systems exchange(Periodic or Event driven) local managed objects if they’re required to be “global” to the Emulated System:– Portal ID

– Portal System Number

– Aggregator Ports assigned to this Portal

– Conversation - administrative Gateway list / operational Gateway

– Conversation - administrative Function Port list / operational Function Port

– FP algorithm and gateway algorithm

– MEP-IDs

– Link Cost ……

Initialize a Portal

IEEE 802 plenary, San Antonio, November 2012

4

• Concerns:– Define DRCP structure, define a DRCP_subtype

following the Slow_Protocols_Type?– Define TLVs for all needed information exchange– The logic of transmitting and receiving DRCPDU– DRCP state machines and LACP state machines may

trigger each other– Each operational managed objects synchronize by

Events driving• LAG entity ready• Aggregator port failure/recovery• Portal System failure/recovery

DRNI

Portal 2Portal 2Portal 1Portal 1

Monitor the Aggregation Port• If one of the Aggregator Port of one DRNI become

unavailable, the Portal System need to:

– Detach the link from the aggregator

– Switch all the affected conversations to their “next highest priority Aggregator Ports (backup Aggregator Port) ”

– Trigger the modification of relative operational parameters

IEEE 802 plenary, San Antonio, November 2012

5

Sys1

Sys2

Sys3

Sys4

X

Monitor the Aggregation Port

• Concerns:– Different conversations may switch to different

backup Aggregator Ports

– Different backup Aggregator Ports may locate on different Portal Systems.

– How to minimize the interaction between Portal Systems? Consider efficient DRCP TLV design.

– If the failure Aggregator Port recovers, should conversations be switched back?

– Need to define DRCPDU TLV structures for the interaction

IEEE 802 plenary, San Antonio, November 2012

6

DRNI

Monitor the IPL and portal system

• Scenario 1 and Scenario 2 may be the same to maintain a Portal if you reference < axbq-nfinn-graceful-name-change-0511-v1.pdf >

• Portal System parameters will Change

• Conversation gateway switch to second Prior Portal System

• Switch conversation to available backup Aggregator Port

• Detach links of the unavailable portal system from the LAG

IEEE 802 plenary, San Antonio, November 2012

7

DRNI

Portal1Portal1

Sys2Sys1

Gateway Gateway

X

Portal1Portal1

Sys2Sys1

Gateway

X

Portal2Portal2

Portal2Portal2

Scenario 1Scenario 1

Scenario 2Scenario 2

Proposals

• Complete the draft about the circumstances and scenarios to make it clear to the implementer.

Thank you!

9IEEE 802 plenary, San Antonio, November

2012