You changed the profit center; see long text
Message no. KO367
Diagnosis
You have changed the profit center from to THI4. This is only allowed when the corresponding configuration was made in Customizing. Then this message is only a warning, which you can ignore.
Procedure
If you want to make it possible to change the profit center, you should change this message from an error message into a warning. To do this choose change message control (application area KO, message number 367).
When you change the profit center, the last period should be settled and since then no more postings should have been made.
Note:You can also use the reorganization to change the profit center.
Notes
Order values can already have been updated on the profit center you are assigning to. For the new assignment, only the new order values on the profit center you are now assigning to are posted.
If an order is assigned to a profit center and the "Integrated Planning" indicator is set, plan costs can be updated in the future on the old profit center.
Change Message Control
In this IMG activity, you set the appearances of system messages to meet your requirements.
You can do the following:
Determine the message type (error, warning, note)
Deactivate messages completely
You can also make different settings for online and background processing.
The corresponding determinations can apply to a client or to an individual user if necessary.
Recommendation
Use standard system messages at the beginning. If a changeable message appears, you have the option of branching to message maintenance from the message long text.
Activities
1. Enter the work area from which the messages come. In Controlling, enter "KI" for CO checks.
2. Choose "Edit -> New entries".
3. Enter the following data:
o Message number
Note that you can change only certain messages in a work area; others are fixed.
o User name
If you enter a name, the settings are valid for this user only. If you enter a blank space, the settings are valid for all client users.
o Message type
Enter the given message type.
o Save your entries. The message texts are automatically implemented.
Note on transport