The Sun is the giver of life. Our generation is not the first to realize the power of sun or harness it for the benefit of mankind. But we are ,perhaps, the first generation to need of source of energy that is both inexpensive and unlimited.
Being the source of all energy and light, sun is the maker of all the six seasons. He is the Omnipresent One who pervades all with countless rays. He is the power behind the seven sense organs, the dispeller of darkness, bestower of happiness and prosperity, the remover of misfortunes and is the infuser of life.
Sun
Equinox Solar Pvt ltd (ESPL) is a solar professional installation and services company based in Rajkot, Gujarat. We are actively involved in providing the techno commercial service in the solar sector, working in close association with client for projects which are realized from the conception to commissioning.
ESPL's genesis was out of compassion for green - clean environment and the zest to find quick solution for power crisis in India without undermining the development of community and ecology. We are methodically focusing on solar energy as it is one of the most preferable power in renewable energy providing sustainable and economical power source.
ESPL is a bankable partner you can trust for providing superior reliable designs, neatly integrated solutions packages and excellent long term technical support. Peace of mind is key to this sector and not every Solar PV Company today offers what we offer. We give assurance of spare parts, services and technical support will continuously available over the 25 + year life a solar installation.
About Company
Why Choose Solar energy ?
Environment
Friendly and
Green energy
Property
Appreciation
Tax Benefits
(15% subsidy,
80% accelerated
depreciation)
Quick
Installation
Emergency
Solution
Infinite Source of energy
No or Low
maintenance
and reliable
Long life
(25years)
Easy To upgrade
?ह�रद�ः सह�ािचः� स�सि�मर� ीिचमान।्ितिमरो�मथनः श�भ��व�ा माता��ड अशमान॥ु ं ु ् �जा�ाण ऋतकता� �भाकरः॥।ु
Key business area
ROOFTOP
PV SYSTEM
SOLAR WATER
PUMPS
GRID
CONNECTED
PV (UTYLITY
SCALE)
End to end solution
Site identification
Design &
Engineering
& noitcer E
& land acquisition
development &
liaisoning
gni noi ssi mmoC
Project development Equinox offers complete end-to-end solutions, resource assessment and feasibility analysis, solar site evaluation and selection, grid analysis and connection and permits and regulatory approvals.
Procurement
Construction
Operation & Maintenance
EngineeringEquinox core team of in-house design experts use cutting-edge software to design the layout and choose the best technology for the solar plant. Equinox produces optimized design for lowest LCOE and higher ROE after thoroughly studding the long term energy prediction analysis.
Equinox access to the best technology solution is facilitated by its wide experience across global supply chain and the long term component partnerships it shares with supply partners resources.
World-class construction management and planning with single point responsibility gives Equinox an edge over the competition. Equinox ensures timely project completion within the estimated budget, establishing a long-term sustainable solution for the customer in the shortest time.
Equinox offer post commissioning monitoring, operations and maintenance support with tailor-made O&M packages for tension-free operation. Apart from established processes and Procedures for proactive and breakdown maintenance, Equinox offers site surveillance support for very large solar projects. Smooth functioning is ensured by a remote monitoring system at Equinox real-time plant technician support, and a well-networked communication channel Office with Discomes & plant owners.
Residentialgrid-interactivesolar with battery backup
Commercial grid-interactivesolar with battery backup
Residential off-grid solar Commercial off-grid solar
Remote community electrification
Solutions We Provide Off Grid - On Grid
Work Strategy
Azadsinh ZankarDirector
Equinox Solar is pooled with resources of technical knowledge coupled with industrial expertise. The services are tailored to meet the unique needs of clients based on rich experience.
We encourage our teams to enhance the interaction with clients for better understanding of client challenges, time lines and work towards the goal without compromising quality standards. Every team is equipped with project management and customer service skills supported with the dedicated acquaintance towards realizing the project.
We maintain good relationships and tie ups with professionals from Industrial, Governments along with the subject experts to bring in latest solutions which make real difference in addressing the issues.
With its continuous effort towards excellence and assisted by highly procient team ESPL has become pioneer in providing consultancy services & installation in the areas of Renewable energy, Energy efciency and clean development mechanism.
We practice international tecniques for solar PV installations. By using unique solar instruments with effective and experienced team (Elect. Engineer for Site Survey and Project analysis),we provide detailed analysis reports for energy consumption and power generation analysis . With in-house Civil Engineer and Architect , we boost of impeccable designs and stability for the solar structure . Also ,care is taken not to temper with the aesthetic appeal of the existing infrastructure..
Naisargi DaveArchitect
Chetansinh GohilEngineer
Divyesh Viramgama
Engineer
Work Profile
Solar Farm Sr. No. Project name Location Capacity Client
Karmaria Bhachau, Kutch 10mw Sunborne1
Dhama - sankheshwar Patan
Solar PumpSr. No. Pump Size Location
3HP Surendranagar1
5HP Hadvad, Morbi
5mw L & T
10HP Rajkot3
2
2
Solar Rooftop (Grid connected & off Grid)Sr. No. Project name Location Capacity Project Type
Shree S V Virani High School Rajkot 35kw Grid connected1
Krishna Chikitsalaya Rajkot 5kw Grid connected2
Shree Jivan Commercial Bank
Equinox Solar Pvt. Ltd. Office
Rajkot
Rajkot
20kw
0.5kw
Grid connected
Smart Grid
3
5
Nilesh Dedania School Upleta 10kw Off-Grid4
5HP Junagadh
5HP Gopinath Paper mills , Surendranagar5
4
World Class Installation Kits. From Site Survey, Array testing & installation kits.
We follow IEC & European codes for Safety & Installation.
Well equipped technical staff, machines and programs
Project : Dhama, Patan
EPC Capacity ESPL
L&T 5mw Civil & Electric Installation
Our Installations
EPC Capacity ESPL
Sunborne 10mw Civil & Electric Installation
Project : Karmaria, Bhachau
Project : Shree S.V. Virani High School
Size
35kw
Solar Pump And Street Light Installations
Type
On Grid
Place
Rajkot
2) PV Studio- instrument selection , project layout and shade analysis
1) PV syst. 6.0 - for complete analaysis - commercial and technical aspects
3) Solar Cert Elements- for sting array test reports and performance audits
Efficiency Scale
International standard For
Energy Generation
Our Energy Generation Ratio
Efficiency of Virani School’s Solar plantU
nit
s C
on
su
med
4776
MA
Y 2
014
5180
JUN
2014
6196
JUL 2
014
10388
AU
G 2
014
7953
SE
P 2
014
8437
OC
T 2
014
5955
NO
V 2
014
6595
DE
C 2
014
1550
FE
B 2
015
4913
JAN
2015
Bill Month-Years Units Consumed
2,000
1,000
10,000
9,000
8,000
7,000
6,000
5,000
4,000
3,000
Consumption Detail
Sr.No.Bill DateMonth-Year
Bill Date (dd-mm-yyyy)
Unitsconsumed
Net PayableAmount(Rs.)
Consumption History
1
23456789
10
FEB-2015
JAN-2015
DEC-2015
NOV-2015
OCT-2015
SEP-2015
AUG-2015
JUL-2015
JUN-2015
MAY-2015
21-01-2015
20-12-2014
21-11-2014
20-10-2014
19-09-2014
21-08-2014
18-07-2014
19-06-2014
20-05-2014
18-04-2014
1550
4913
6595
5955
8437
7953
10388
6196
5180
4776
9,580.22
28,914.04
39,212.29
34,760.13
48,611.14
48,804.39
69,335.64
35,258.98
24,976.61
27,011.92
Project commissioned in january . Bill reduced to Rs. 9500/-
Software Reports for Solar PV Installation
PV Array Test ReportIntial Verication Periodic Verication
INSTALLATION ADDRESSINSTALLATION ADDRESS
DESCRIPTION OF WORK UNDER TESTDESCRIPTION OF WORK UNDER TEST
REFERENCEREFERENCE
DATEDATE
INSPECTORINSPECTOR
TEST INSTRUMENTSTEST INSTRUMENTS
SPV VIRANI HIGH SCHOOLTAGORE MARGVIRANI CHOWKRAJKOT-360001GUJARAT ,INDIA
Supply, install and comission 35 kW grid connected PV system at VIRANI SCHOOL - RAJKOT
ALL THE EIGHT STRING INSPECTED ,CURRENT ,Isc,Voc, ARRAY ,STRING VOLTAGE , INVERTER OUTPUT AND EFFICENCY TESTED. THIS REPORT IS FOR FOR FIRST 6 STRING(OUT OF 8 STRING)
ESPL -0012014/15
29/1/2015
ESPL ENGINEER
SEAWARD SOLAR PV 150
STRING STRING 11 22 33 44 55 66
Array Module
Quantity
Array parameters(as specied)
Voc (stc)
Isc (stc)
String over-current protective device
Type
Rating (A)
D Rating (V)
Capacity (kA)
Wiring Type
Phase (mm2)
Earth (mm2)
String test Voc (V)
Isc (A)
Irradiance
Polarity Check
Array insulation resistance
Test voltage (V)
Pos - Earth (MΩ)
Neg - Earth (M
Earth continuity (where tted)
Switchgear functioning correctly
Inverter make / model
Inverter serial number
Inverter functioning correctly
Loss of mains test
Comments
JJ SOLAR- JP60F230
20
36.8
8.4
N/A
N/A
N/A
N/A
PVC
4mm2
2.5mm2
635
8.11
889.0
1000
>199
>199
0.25
PASS
01414100100
PASS
PASS
19
36.8
8.4
N/A
N/A
N/A
N/A
PVC
4mm2
2.5mm2
628
8.11
907.3
1000
>199
>199
0.24
PASS
01414100099
PASS
PASS
19
36.8
8.4
N/A
N/A
N/A
N/A
PVC
4mm2
2.5mm2
677
8.03
900.8
1000
>199
>199
0.22
PASS
01414100099
PASS
PASS
19
36.8
8.4
N/A
N/A
N/A
N/A
PVC
4mm2
2.5mm2
669
8.14
912.9
1000
>199
>199
0.15
PASS
01414100099
PASS
PASS
19
36.8
8.4
N/A
N/A
N/A
N/A
PVC
4mm2
2.5mm2
633
8.05
903.1
1000
>199
>199
0.15
PASS
01414100099
PASS
PASS
19
36.8
8.4
N/A
N/A
N/A
N/A
PVC
4mm2
2.5mm2
632
8.10
905.5
1000
>199
>199
0.15
PASS
DELTA- RPI M20A
01414100100
PASS
PASS
Index=2; Ta (C)=30.21; Tp (C)=31.66; HH:MM:SS=12:47:28; Index=3; Ta (C)=31.16; Tp (C)=31.51; HH:MM:SS=12:49:48; Index=4; Ta (C)=32.57; Tp (C)=32.41; HH:MM:SS=12:51:2; Index=6; Ta (C)=32.82; Tp (C)=33.72; HH:MM:SS=12:53:43; Index=7; Ta (C)=32.82; Tp (C)=34.12; HH:MM:SS=12:58:9; Index=8; Ta (C)=32.77; Tp (C)=35.07; HH:MM:SS=12:59:11;
Created by SolarCert Elements licensed to Equinox Solar Pvt. Ltd.
EQUINOXEQUINOXEQUINOX SOLAR
TM
Ω)
DELTA- RPI M20ADELTA- RPI M20ADELTA- RPI M20ADELTA- RPI M20ADELTA- RPI M20A
JJ SOLAR- JP60F230 JJ SOLAR- JP60F230 JJ SOLAR- JP60F230 JJ SOLAR- JP60F230 JJ SOLAR- JP60F230
3 EQUINOX SOLAR PVT LTD Report generated by SolarPathnder Assistant Version 1.11.1.0. http://www.solarpathnder.com
EQUINOX SOLAR PVT LTDMonthly Production Graph
EQUINOX SOLAR PVT LTDJivan Commercial Bank: Solar Target
Percent of Total Annual Insolation
Roof Setbacks Top = 0 mm, Right = 0 mm, Bottom = 0 mm, Left = 0 mm
Spacing Between Modules Vertical = 0 mm, Horizontal = 0 mm
4 EQUINOX SOLAR PVT LTD Report generated by SolarPathnder Assistant Version 1.11.1.0. http://www.solarpathnder.com
EQUINOX SOLAR PVT LTDJivan Commercial Bank: Summary Results
Array Type Fixed Angle
Tilt Angle 22.30 deg
Ideal Tilt Angle 22.30 deg
Azimuth 180.00 deg
Ideal Azimuth 180.00 deg
Combined Inverter Efficiency 98.6 %
System Loss Percentage 10.0 %
DC to AC Derate Factor 0.887
Unshaded Percent 94.6 %
Array DC Rating 18.71 kW
Array AC Rating 16.6 kW
Inverter 1 Huawei Technologies CO., LTD, SUN2000-20KTL (22,500 Watts, Efciency = 99 %)
Module Name Vikram Solar Pvt. Limited, ELDORA 230 (230) (230 Watts)
Module Type Standard
Equipment Count 1 inverter & 86 modules
Inverter/Module Configuration:
Inverter 1
3 strings - 23 modules per string
1 string - 17 modules
Solar Obstruction Data (Part 1 of 2)Month Unshaded % of
Ideal SiteAzimuth=180Tilt=22.3
Ideal UnshadedSolar RadiationAzimuth=180(S)Tilt=22.3kWh/m²
ActualUnshadedSolar RadiationAzimuth=180.0Tilt=22.3kWh/m²
Actual ShadedSolar RadiationAzimuth=180.0Tilt=22.3kWh/m²
Unshaded % ofActual SiteAzimuth=180.0Tilt=22.30
Actual SiteEfficiency %Azimuth=180.0Tilt=22.30
Ideal SiteEfficiency %Azimuth=180(S)Tilt=22.3
January 86.67 % 6.01 6.01 5.09 84.72 % 84.72 % 84.72 %
February 92.47 % 6.92 6.92 6.29 90.83 % 90.83 % 90.83 %
March 93.07 % 6.70 6.70 6.14 91.56 % 91.56 % 91.56 %
April 96.06 % 7.07 7.07 6.73 95.22 % 95.22 % 95.22 %
May 98.10 % 6.52 6.52 6.41 98.25 % 98.25 % 98.25 %
June 98.68 % 4.95 4.95 4.89 98.84 % 98.84 % 98.84 %
July 97.63 % 4.11 4.11 4.02 98.02 % 98.02 % 98.02 %
August 97.08 % 4.10 4.10 3.95 96.33 % 96.33 % 96.33 %
September 92.64 % 6.34 6.34 5.83 92.02 % 92.02 % 92.02 %
October 94.48 % 6.98 6.98 6.55 93.87 % 93.87 % 93.87 %
November 89.73 % 6.87 6.87 6.12 89.18 % 89.18 % 89.18 %
December 87.16 % 6.44 6.44 5.54 85.99 % 85.99 % 85.99 %
Totals 93.65%UnweightedYearly Avg
73.00Effect: 100.00%
Sun Hrs: 6.08
73.00Effect: 100.00%
Sun Hrs: 6.08
67.56Effect: 92.55%Sun Hrs: 5.63
92.55%UnweightedYearly Avg
92.55%UnweightedYearly Avg
92.55%UnweightedYearly Avg
5 EQUINOX SOLAR PVT LTD Report generated by SolarPathnder Assistant Version 1.11.1.0. http://www.solarpathnder.com
EQUINOX SOLAR PVT LTDSite Survey Images and Data
Site Image Name: "IMG20150320122810.jpg"
Unshaded Percent = 80 %
Azimuth/Altitude Data
Azimuth / Altitude (degrees) where South = 0 degrees
-125 0.5 -80 15.0 -35 36.0 10 17.5 55 28.5 100 37.0
-120 (ENE) 0.5 -75 15.0 -30 (SSE) 34.0 15 17.5 60 (WSW) 30.5 105 32.5
-115 9.5 -70 17.0 -25 31.5 20 17.0 65 32.5 110 28.5
-110 19.0 -65 21.0 -20 26.5 25 17.0 70 34.5 115 8.0
-105 22.0 -60 (ESE) 25.5 -15 18.5 30 (SSW) 17.0 75 36.5 120 (WNW) 5.5
-100 22.5 -55 31.0 -10 18.5 35 16.5 80 44.0 125 5.5
-95 22.5 -50 35.0 -5 18.0 40 17.0 85 42.5
-90 (E) 22.5 -45 (SE) 36.0 0 (S) 18.0 45 (SW) 21.5 90 (W) 41.5
-85 14.5 -40 36.5 5 17.5 50 26.0 95 40.5
8 EQUINOX SOLAR PVT LTD Report generated by SolarPathnder Assistant Version 1.11.1.0. http://www.solarpathnder.com
EQUINOX SOLAR PVT LTDSite Survey Images and Data
Site Image Name: "IMG20150320122720.jpg"
Array Type Fixed Angle
Tilt Angle 22.30 deg
Ideal Tilt Angle 22.30 deg
Azimuth 180.00 deg
Ideal Azimuth 180.00 deg
Solar Obstruction DataMonth Unshaded % of
Ideal SiteAzimuth=180Tilt=22.3
Ideal UnshadedSolar RadiationAzimuth=180(S)Tilt=22.3kWh/m²
ActualUnshadedSolar RadiationAzimuth=180.0Tilt=22.3kWh/m²
Actual ShadedSolar RadiationAzimuth=180.0Tilt=22.3kWh/m²
Unshaded % ofActual SiteAzimuth=180.0Tilt=22.30
Actual SiteEfficiency %Azimuth=180.0Tilt=22.30
Ideal SiteEfficiency %Azimuth=180(S)Tilt=22.3
January 77.35 % 6.01 6.01 4.45 74.07 % 74.07 % 74.07 %
February 86.78 % 6.92 6.92 5.81 83.97 % 83.97 % 83.97 %
March 87.05 % 6.70 6.70 5.65 84.34 % 84.34 % 84.34 %
April 95.02 % 7.07 7.07 6.63 93.81 % 93.81 % 93.81 %
May 99.34 % 6.52 6.52 6.49 99.59 % 99.59 % 99.59 %
June 99.45 % 4.95 4.95 4.94 99.80 % 99.80 % 99.80 %
July 98.82 % 4.11 4.11 4.09 99.58 % 99.58 % 99.58 %
August 98.82 % 4.10 4.10 4.02 98.01 % 98.01 % 98.01 %
September 87.03 % 6.34 6.34 5.41 85.31 % 85.31 % 85.31 %
October 90.62 % 6.98 6.98 6.27 89.84 % 89.84 % 89.84 %
November 83.64 % 6.87 6.87 5.67 82.57 % 82.57 % 82.57 %
December 79.17 % 6.44 6.44 4.98 77.33 % 77.33 % 77.33 %
Totals 90.26%UnweightedYearly Avg
73.00Effect: 100.00%
Sun Hrs: 6.08
73.00Effect: 100.00%
Sun Hrs: 6.08
64.41Effect: 88.24%Sun Hrs: 5.37
88.24%UnweightedYearly Avg
88.24%UnweightedYearly Avg
88.24%UnweightedYearly Avg
9 EQUINOX SOLAR PVT LTD Report generated by SolarPathnder Assistant Version 1.11.1.0. http://www.solarpathnder.com 6 EQUINOX SOLAR PVT LTD Report generated by SolarPathnder Assistant Version 1.11.1.0. http://www.solarpathnder.com
EQUINOX SOLAR PVT LTDJivan Commercial Bank: Summary Results
Solar Obstruction Data (Part 2 of 2)Month Actual Shaded
AC Energy (kWh)Azimuth=180.00Tilt=22.30
Actual UnshadedAC Energy (kWh)Azimuth=180.0Tilt=22.30
Ideal UnshadedAC Energy (kWh)Azimuth=180.0Tilt=22.30
PV SolarCost Savings0.15 ($/kWh)
January 2,612.29 3,096.00 3,096.00 $391.84
February 2,857.28 3,096.00 3,096.00 $428.59
March 2,938.67 3,182.00 3,182.00 $440.80
April 3,109.45 3,268.00 3,268.00 $466.42
May 3,048.83 3,096.00 3,096.00 $457.32
June 2,215.38 2,236.00 2,236.00 $332.31
July 2,031.84 2,064.00 2,064.00 $304.78
August 1,920.01 1,978.00 1,978.00 $288.00
September 2,733.66 2,924.00 2,924.00 $410.05
October 3,051.78 3,268.00 3,268.00 $457.77
November 2,731.87 3,010.00 3,010.00 $409.78
December 2,749.79 3,182.00 3,182.00 $412.47
Totals 32,000.83 34,400.00 34,400.00 $4,800.12