EQ‐DCM EQ‐DCM C

   

to MicroLogConfiguration

gix & SLC500n MLX on DF1

0 Using RSLI1 CHA and SLC

INX RSLOGIXC503 on DF1 C

X500 & AB ECHB 

Ethernet IGSS driver 

 

 

 

Page 2: EQ-DCM to MicroLogix & SLC500 Using RSLINX RSLOGIX500 & …€¦ · GIX 500 and below, you c ix & SLC503 u dd another d go online wi an see in the sing the two river for the th Micro

Start RSLI

From the 

Type a na

Under Staname typ

NX and click o

drop menu s

me for the dr

ation type thee the IP addr

on Configure 

elect Etherne

river and click

e node addresess of the EQ

drivers icon.

et devices and

k on OK 

 ss of the Micr

Q‐DCM, click o

d click on Add

roLogix here on apply then

 d New 

in this applica click on OK

ation node 4,, then under H

 

 

Host 

Page 3: EQ-DCM to MicroLogix & SLC500 Using RSLINX RSLOGIX500 & …€¦ · GIX 500 and below, you c ix & SLC503 u dd another d go online wi an see in the sing the two river for the th Micro

Repeat sa

Start RSLOas shown MicroLog

ame steps to a

OGIX 500 andbelow, you cix & SLC503 u

add another d

d go online wican see in theusing the two

driver for the

 

th Micro Log next two scr AB Ethernet 

e SLC/503 

ix and the SLCreen shots RSDrivers adde

C‐503 using tLINX and RSLed for each PL

he two driveLOGIX 500 onLC.

 

rs added aboline with both

 ve,  h 

Page 4: EQ-DCM to MicroLogix & SLC500 Using RSLINX RSLOGIX500 & …€¦ · GIX 500 and below, you c ix & SLC503 u dd another d go online wi an see in the sing the two river for the th Micro

Now to sechannel a

ee that we cand type its na

n get data froame Select Al

om both the Mllen Bradley E

MicroLogix anEtherne from 

nd the SLC/50Device drive

03 using IGS, r drop menu.

 start IGS, add. 

d new 

 

 

Page 5: EQ-DCM to MicroLogix & SLC500 Using RSLINX RSLOGIX500 & …€¦ · GIX 500 and below, you c ix & SLC503 u dd another d go online wi an see in the sing the two river for the th Micro

Add New  

 Select SLC 

 Click On N

  

Device and ty

C5/05 from D

Next 

ype its name 

evice model d

here we type

drop menu an

ed MLX 1000 

nd type the E

for the Micro

EQ‐DCM IP ad

oLogix 1000 

ddress under Device ID 

 

 

 

Page 6: EQ-DCM to MicroLogix & SLC500 Using RSLINX RSLOGIX500 & …€¦ · GIX 500 and below, you c ix & SLC503 u dd another d go online wi an see in the sing the two river for the th Micro

Leave thewhich is 4

 Click On N 

 Add tags,  

e Port number4 as shown. 

Next and then

here we add

r to default 2

n on Finish 

ed 5 words fr

222 and then

rom Integer f

n type in the D

ile N7 startin

Destination n

g at word 0 

node address of the MicroLLogix 

 

 

 

Page 7: EQ-DCM to MicroLogix & SLC500 Using RSLINX RSLOGIX500 & …€¦ · GIX 500 and below, you c ix & SLC503 u dd another d go online wi an see in the sing the two river for the th Micro

Start OPC

Here can 

Now repe

C Quick client 

see values of

eat add new d

to confirm th

f integer file N

device in IGS f

hat we can re

N7 from both 

for SLC503 

ad data of int

RSLINX and I

teger file 7 fro

IGS in MicroL

om the Micro

 Logix. 

o Logix 1000.

 

 

Page 8: EQ-DCM to MicroLogix & SLC500 Using RSLINX RSLOGIX500 & …€¦ · GIX 500 and below, you c ix & SLC503 u dd another d go online wi an see in the sing the two river for the th Micro

 

Here the node addresss number of tthe SLC503 is 5 entered as destination.

 

 

 

Page 9: EQ-DCM to MicroLogix & SLC500 Using RSLINX RSLOGIX500 & …€¦ · GIX 500 and below, you c ix & SLC503 u dd another d go online wi an see in the sing the two river for the th Micro

 Adding a t 

 Start OPC

tag to read 10

C Quick Client 

0 words from

to confirm N

m the SLC/503

7 data can be

3 integer file N

e read from t

N7. 

he SLC503. 

 

 

 

Page 10: EQ-DCM to MicroLogix & SLC500 Using RSLINX RSLOGIX500 & …€¦ · GIX 500 and below, you c ix & SLC503 u dd another d go online wi an see in the sing the two river for the th Micro

Here can Client. 

see values off integer file NN7 in the SLC5503 using botth RSLINX datta monitor annd IGS OPC Quuick