23
Pre Sales Dept. EOLO Extra kW HP EOLO Extra kW HP Wall hung boiler with condensing heat exchanger Wall hung boiler with condensing heat exchanger , , for for high high temperature systems temperature systems

EOLO Extra kW HP Wall hung boiler with condensing heat exchanger , for high temperature systems

  • Upload
    aliza

  • View
    23

  • Download
    3

Embed Size (px)

DESCRIPTION

EOLO Extra kW HP Wall hung boiler with condensing heat exchanger , for high temperature systems. Main features. New models Functioning Efficiency Dimensions and connections Control panel Applications Outdoor installation Main Option kits Availability and list price. New Models. - PowerPoint PPT Presentation

Citation preview

Page 1: EOLO Extra kW HP Wall hung boiler with condensing heat exchanger ,  for  high  temperature systems

Pre Sales Dept.

EOLO Extra kW HPEOLO Extra kW HPWall hung boiler with condensing heat exchangerWall hung boiler with condensing heat exchanger, , for for high high temperature systemstemperature systems

Page 2: EOLO Extra kW HP Wall hung boiler with condensing heat exchanger ,  for  high  temperature systems

Pre Sales Dept.

Main featuresMain features

▪ New models

▪ Functioning

▪ Efficiency

▪ Dimensions and connections

▪ Control panel

▪ Applications

▪ Outdoor installation

▪ Main Option kits

▪ Availability and list price

Page 3: EOLO Extra kW HP Wall hung boiler with condensing heat exchanger ,  for  high  temperature systems

Pre Sales Dept.

New ModelsNew Models

Immergas expands its range of condensing boilers with the new EOLO Extra kW HP range.

The new boilers are characterized by the presence of a traditional heat exchanger (copper made) combined to a special condensing heat exchanger.

Page 4: EOLO Extra kW HP Wall hung boiler with condensing heat exchanger ,  for  high  temperature systems

Pre Sales Dept.

New versions EOLO Extra kW HP represent the Entry Level in the Immergas condensing range.

This solution takes the advantages of the condensation technology and it represents the best choice for residential new buildings (where price assumes detail relief) or in case of traditional boiler substitutions.

Applications

Page 5: EOLO Extra kW HP Wall hung boiler with condensing heat exchanger ,  for  high  temperature systems

Pre Sales Dept.

FeaturesFeatures

▪ Two models with heat outputs of 24 e 30 kW

▪ Instantaneous production of D.H.W

▪ Designed for traditional systems, working with high temperatures only (for example radiators).

▪ Outdoor and indoor installation (IPX5D)

Page 6: EOLO Extra kW HP Wall hung boiler with condensing heat exchanger ,  for  high  temperature systems

Pre Sales Dept.

FeaturesFeatures

▪ Special condensing heat exchanger, located downstream main heat

exchanger

▪ Remarkable structural simplicity, thanks to a conventional boilerlike frame

▪ High efficiencies

▪ Compact dimensions(25 cm depth)

Page 7: EOLO Extra kW HP Wall hung boiler with condensing heat exchanger ,  for  high  temperature systems

Pre Sales Dept.

The structure is completely similar to a traditional boiler with copper heat exchanger, to which a special Aluminium

condensing exchanger has been added in series.

FunctioningFunctioning

Heat Recover

Page 8: EOLO Extra kW HP Wall hung boiler with condensing heat exchanger ,  for  high  temperature systems

Pre Sales Dept.

The heat recover absorbs a further part of the heat contained in the fumes, allowing to preheat the water before the primary heat exchanger.

FunctioningFunctioning

Heat Recover

Condensate drain pipe

Primary Heat Exchanger

Page 9: EOLO Extra kW HP Wall hung boiler with condensing heat exchanger ,  for  high  temperature systems

Pre Sales Dept.

Efficiency targets are analogous to ones of Condensing BoilersEfficiency at nominal heat output (80/60 °C):• EOLO Extra 24 kW HP = 97,3 %• EOLO Extra 30 kW HP = 96,4 %

EfficiencyEfficiency

Page 10: EOLO Extra kW HP Wall hung boiler with condensing heat exchanger ,  for  high  temperature systems

Pre Sales Dept.

only 25 cm depth

standard provided with anti-freeze -5 ºC (-15 °C with option kit)

Dimensions and connectionsDimensions and connections

Page 11: EOLO Extra kW HP Wall hung boiler with condensing heat exchanger ,  for  high  temperature systems

Pre Sales Dept.

Control panelControl panel

1 - Stand-by 2 - Burner ON3 - D.H.W. ON4 – Central heating ON5 - Temperature / Ignition lock6 - Temperature / Flue pressure switch safety7 - Temperature / Low system pressure8 - Temperature / Insufficient circulation9 - Temperature / Delivery NTC probe faulty10 - Temperature / D.h.w. NTC probe faulty 11 - Temperature / Overheating lock 12 - Main switch (stand by, d.h.w., c.h. and reset)13 - D.H.W. Temperature knob14 - Central heating temperature knob15 - Manometer

Page 12: EOLO Extra kW HP Wall hung boiler with condensing heat exchanger ,  for  high  temperature systems

Pre Sales Dept.

Schema idraulicoSchema idraulico1 - D.h.w. flow switch2 - Limitatore di flusso3 - System filling valve 4 - D.h.w. probe5 - 3 bar safety valve6 - Gas valve7 - Burner8 – Sealed room9 – Primary heat exchanger10 – Draught diverter11 - Fan12 – Flue pressure switch13 – Flue thermostat14 - Secondary heat exchanger 15 – Delivery probe16 – Safety thermostat17 – Expansion vessel18 – Air vent19 - Circulator20 – System pressure switch21 – D.h.w. plated heat exchanger22 – Motorzed 3 way valve23 – Automatic bypass24 – Draining valve 25 – Condensing drain

Page 13: EOLO Extra kW HP Wall hung boiler with condensing heat exchanger ,  for  high  temperature systems

Pre Sales Dept.

A = Available head with zone’s circulator speed set at maximum by pass excludedB = Available head with zone’s circulator speed set at maximumcon by pass includedC = Available head with zone’s circulator speed set to 2 con by pass excludedD = Available head with zone’s circulator speed set to 2 con by pass included

Diagram of the pumpDiagram of the pump – – 24 version24 version

Flow rate (l/h)

Head (

mH

2O)

Head (

kPa)

Page 14: EOLO Extra kW HP Wall hung boiler with condensing heat exchanger ,  for  high  temperature systems

Pre Sales Dept.

A = Available head with zone’s circulator speed set at maximum by pass excludedB = Available head with zone’s circulator speed set at maximumcon by pass includedC = Available head with zone’s circulator speed set to 2 con by pass excludedD = Available head with zone’s circulator speed set to 2 con by pass included

Diagram of the pumpDiagram of the pump – – 30 version30 version

Flow rate (l/h)

Head (

mH

2O)

Head (

kPa)

Page 15: EOLO Extra kW HP Wall hung boiler with condensing heat exchanger ,  for  high  temperature systems

Pre Sales Dept.

The main difference with the condensing models is that EOLO EXTRA kW HP are designed for traditional systems, working with high temperatures only (for example radiators).

Applications

Page 16: EOLO Extra kW HP Wall hung boiler with condensing heat exchanger ,  for  high  temperature systems

Pre Sales Dept.

The EOLO Extra kW HP models can’t be combined directly to underfloor panels (low temperature systems).

Applications

Page 17: EOLO Extra kW HP Wall hung boiler with condensing heat exchanger ,  for  high  temperature systems

Pre Sales Dept.

• Simple condensate disposal, thanks to built siphon, similarly to other condensing models

Condensing drainCondensing drain

Page 18: EOLO Extra kW HP Wall hung boiler with condensing heat exchanger ,  for  high  temperature systems

Pre Sales Dept.

The boiler can be installed outside, in partially protected places (for example under a balcony); the protection index is IPX5D.

Outdoor installationOutdoor installation

Page 19: EOLO Extra kW HP Wall hung boiler with condensing heat exchanger ,  for  high  temperature systems

Pre Sales Dept.

Amico Remote Control (CAR)

External Sensor

• Central heating temperature modulation according to the external and internal temperatures means lower consumption

Climatic thermoregulationClimatic thermoregulation(optionals) (optionals)

Page 20: EOLO Extra kW HP Wall hung boiler with condensing heat exchanger ,  for  high  temperature systems

Pre Sales Dept.

Climatic programmer and modulating room thermostat

Easy to use thanks to a wide display and only onesetting knob

Super CAR Remote ControlSuper CAR Remote Control(optional)(optional)

Page 21: EOLO Extra kW HP Wall hung boiler with condensing heat exchanger ,  for  high  temperature systems

Pre Sales Dept.

Option kitsOption kits

• Connection kit cod. 3.019329

• Anti-freeze protection kit a -15 °C cod. 3.017324

• Cover kit cod. 3.016022

• Additional 2 litres expansion vessel cod. 3.016224

• Telephonic Remote Control cod. 3.013305

• DIM range

Page 22: EOLO Extra kW HP Wall hung boiler with condensing heat exchanger ,  for  high  temperature systems

Pre Sales Dept.

EOLO Extra kW HP can be matched to the same flue pipes for the other Immergas condensing models;

the main kit options are:

• Twin pipe kit Ø 80/80 cod. 3.012002

• Concentric horizontal kit Ø 60/100 cod. 3.012000

• Concentric vertical kit Ø 60/100 cod. 3.016833

Flue pipes green rangeFlue pipes green range

Page 23: EOLO Extra kW HP Wall hung boiler with condensing heat exchanger ,  for  high  temperature systems

Pre Sales Dept.

Availability and price listAvailability and price list

Model Availability List price

EOLO Extra 24 kW HP

code 3.021037

February 2010 1760,00 €