10
GAS DETECTION: SPECIALTY Interscan Portable Analyzers 4000 Series 84 Cerex Portable Analyzers AirSentry FTIR Open Path Multi-Gas Analyzer 85 Sentry Series Open Path 86 Multi-Gas Analyzers 86 UV 3000 Series Multi-Gas Analyzers 87 FT 5000 Series Multi-Gas Analyzers 88 Environmental Survey/Purging Monitors VRAE 89 RKI Eagle 2 89 AreaRAE 89 ChemKey T TLV 90 Chemcassette 90 SPM 90 Specialized Gas Detection Gem5000 91 G100 CO 2 Incubator Analyzer 91 G110 CO 2 Analyzer 91 G150 CO 2 Indoor Air Quality Analyzer 92 G200 N 2 O 0-1,000 ppm Gas Analyzer 92 G210 N 2 O 0-100% Gas Analyzer 92 Flame Ionization Detectors Thermo Scientific TVA-1000B Portable FID/PID 92 83

ENVIRONMENTAL SURVEY/PURGING MONITORS GAS DETECTION: SPECIALTY · 83 ENVIRONMENTAL SURVEY/PURGING MONITORS GAS DETECTION: SPECIALTY Interscan Portable Analyzers 4000 Series 84 Cerex

  • Upload
    doanque

  • View
    230

  • Download
    1

Embed Size (px)

Citation preview

83www.conceptcontrols.com

ENVIRONMENTAL SURVEY/PURGING MONITORS

GAS DETECTION: SPECIALTYInterscan Portable Analyzers

4000 Series 84Cerex Portable Analyzers

AirSentry FTIR Open Path Multi-Gas Analyzer 85Sentry Series Open Path 86Multi-Gas Analyzers 86UV 3000 Series Multi-Gas Analyzers 87FT 5000 Series Multi-Gas Analyzers 88

Environmental Survey/Purging MonitorsVRAE 89RKI Eagle 2 89AreaRAE 89ChemKeyT TLV 90Chemcassette 90SPM 90

Specialized Gas DetectionGem5000 91G100 CO2 Incubator Analyzer 91G110 CO2 Analyzer 91G150 CO2 Indoor Air Quality Analyzer 92G200 N2O 0-1,000 ppm Gas Analyzer 92G210 N2O 0-100% Gas Analyzer 92

Flame Ionization DetectorsThermo Scientific TVA-1000B Portable FID/PID 92

83

GAS DETECTION: SPECIALTY

84 www.conceptcontrols.com

4000 SeriesInterscan’s 4000 Series Portable Analyzers are perfect for survey work and short-term continuous monitoring duty. The analyzers are provided with:

Features:• 3-1/2 digit LCD display• 58 sensor options• Integral sample pump & plug-in

charger• User-adjustable single alarm

level activating audible and visual alarm

• 0-100 mV output• Carrying case with shoulder strap• 12 inch (30.5 cm) Teflon sample

probe

UL-Classified intrinsically safe models are available.

Ordering InformationGas Range MODEL No.Br2 0-19.99 ppm 4700-19.99mBromine 0-1999 ppb 4700-1999bCO 0-1999 ppm 4140-1999mCarbon Monoxide 0-500.0 ppm 4140-500.0m

0-199.9 ppm 4140-199.9mCl2 0-5.00ppm 4340-5.00mChlorine 0-19.99 ppm 4340-19.99m

0-1999 ppb 4340-1999bClO2 0-19.99 ppm 4330-19.99mChlorine Dioxide 0-1000 ppb 4330-1000b

0-1999 ppb 4330-1999bC2H4 0-1999 ppm 4070-1999mEthylene 0-199.9 ppm 4070-199.9m

0-19.99 ppm 4070-19.99m0-500.0 ppm 470-500.0m0-1999 ppb 4070-1999b

EtO 0-19.99 ppm 4200-19.99mEthylene Oxide 0-50.0 ppm 4200-50.0m

0-1000 ppb 4200-1000b0-1999 ppb 4200-1999b

HCHO 0-5.00 ppm 4160-5.00mFormaldehyde 0-19.99 ppm 4160-19.99m

0-1000 ppb 4160-1000b0-1999 ppb 4160-1999b

H2NNH2 0-1000 ppb 4180-1000bCH3NHNH2 0-1999 ppb 4180-1999b(CH3)2NNH2HBr 0-19.99 ppm 4800-19.99mHydrogen Bromide 0-1999 ppb 4800-1999bHCl 0-19.99 ppm 4360-19.99mHydrogen Chloride 0-1999 ppb 4360-1999bHCN 0-19.99 ppm 4280-19.99mHydrogen Cyanide 0-199.9 ppm 4280-199.9m

0-1999 ppb 4280-1999b

H2S 0-19.99 ppm 4170-19.99mHydrogen Sulfide 0-1000ppb 4170-1000b

0-500 ppb 4170-500b0-1999 ppb 4170-1999b

NO 0-199.9 ppm 4540-199.9mNitric Oxide 0-19.99 ppm 4540-19.99m

0-1999 ppb 4540-1999bNO2 0-199.9 ppm 4150-199.9mNitrogen Dioxide 0-19.99 ppm 4150-19.99m

0-1999 ppb 4150-1999bO3 0-19.99 ppm 4480-19.99mOzone 0-1999 ppb 4480-1999bPrO 0-199.9 ppm 4320-199.9mPropylene Oxide 0-19.99 ppm 4320-19.99m

0-1999 ppb 4320-1999bSO2 0-19.99 ppm 4240-19.99mSulfur Dioxide 0-50.0 ppm 4240-50.0m

0-1999 ppb 4240-1999bUL Listed ModelsH2NNH2 0-0.5/0-2 ppm 4183UL

CH3NHNH2 0-2/0-10 ppm 4186UL

(CH3)2NNH2 0-100/0-2000 ppb 4187UL

Hydrazine 0-100/0-1000 ppb 4189UL

NO2 0-2/0-10 ppm 4152UL

Nitrogen Dioxide 0-10/0-50 ppm 4154UL

INTERSCAN PORTABLE ANALYZERS

85www.conceptcontrols.com

AirSentry FTIR Open Path Multi-Gas AnalyzerThe Cerex AirSentry FTIR multi-gas analyzer is the recognized choice in open path FTIR and the most reliable for monitoring industrial facilities, accidental releases, and hazardous waste site emissions. The system monitors from 5 to 1,000 metres and eliminates the need for many single point gas specific sensors, lengthy calibration, and laboratory analysis.

The AirSentry FTIR is the only commercial open-path FTIR evaluated in two USEPA site studies and proven capable of detecting, identifying, and quantifying air toxins. It is efficient as an alarm and easily integrated into your existing alarm system.

Typical Minimum Detection of Commonly Requested Single Gases: 300 Metre Path:

CEREX PORTABLE ANALYZERS

CEREX PORTABLE ANALYZERS

Compound PPB Acetaldehyde 2Acetic Acid, monomer 4.7Acetone 9.7Acetonotrile 43.3Acetl Chloride 2.2Acetylene 2.6Acrolein 2.8Acrylic Acid 1.5Acrylonitrile 5Ammonia 0.7Aniline 13Arsine 5.7Benzene 110Bis-dichloroethylether 2.3Boron Trichloride 0.7Bromomethane 27.3Butadiene 3.1n-Butane 72-Butanone 7Carbon Dioxide 43.7Carbon Disulfide 11.3Carbon Monoxide 4.3Carbon Tetrachloride 0.8Carbon Tetrafluoride 0.7Carbonyl Sulfide 1.6Chlorobenzene 5Chlorodifluoromethane 0.7Crotonaldehyde 2.5Chloroethane 6.7Chloroform 0.8Chloromethane 31.3Chlorotrifluoromethane 2Cyclohexane 0.7Cyclohexene 2.4Cyclopentene 4.3Cyclopropane 6.71,2 Dibromoethane 7.7m-Dichlorobenzene 4o-Dichlorobenzene 3.1Dichlorodifluoromethane 0.71,1 Dichloroethane 3.71,2 Dichloroethane 24.31,1 Dichloroethene 2.31,2 Dichloroethene 6.7

Compound PPB 4-Methyl 2-Pentene 4Methyl Vinyl Ether 4.7Methyl Vinyl Ketone 6.3Nitric Acid 2.1Nitric Acid 76.7Nitro Benzene 4.3Nitro Ethane 10Nitrogen Dioxide 9.7Nitro Methane 27Nitrous Acid 0.7Nitrous Oxide 6.3Octane 0.8Ozone 2.2n-Pentane 2.81-Pentene 3.32-Pentene 5trans-3-Pentene nitrile 2Phosgene 0.7Phosphine 9Propane 6.3Propionaldehyde 1.6Propionic Acid 7.3Propylene 4.7Propylene Oxide 7.3Silicon Tetrafluoride 0.7Styrene 4Sulfur Dioxide 15Sulfur Hexafluoride 0.71,1,1,2 Tetrachloroethane 1.31,1,1,2 Tetrachloroethane 133.3Tetrachloroethene 0.7Tetrahydrothiophene 3Toluene 11.31,1,1 Trichloroethane 1.81,1,2 Trichloroethane 4.7Trichloroethene 0.8Trichlorofluormethane 0.7Trochlorotrifluoroethane 0.7Vinyl Acetate 2.5Vinyl Chloride 5.3Vinylidene Chloride 2.3m-Xylene 5o-Xylene 9p-Xylene 4.7

Compound PPB Dichloromethane 4.31,2 Dichlorotetrafluorethane 0.7Diethyl Ether 0.9Dimethylamine 2.4Dimethyl Ether 31,1 Dimethyl Hydrazine 1.2Dimethyl Sulfide 1Ethane 5.3Ethanol 3Ethyl Benzene 11.3Ethylene 2.1Ethylene Oxide 3.7Ethyl Vinyl Ether 4Fluorobenzene 5.7Formaldehyde 1.5Formic Acid, Monomer 2.6Furan 3.7n-Hexane 1.5Hydrogen Bromide 4Hydrogen Chloride 2Hydrogen Cyanide 22.7Hydrogen Fluoride 0.7Hydrogen Sulfide 1500Isobutane 2.5Isobutanol 1.1Isobutylene 1.4Isoctane 2Isoprene 1.5Isopropanol 3.7Mesitylene 3.1Methane 11.7Methanol 1.4Methyl Acetate 2.7Methyl Acrylate 2.2Methylamine 9.72-Methyl 2-Butene 15.73-Methyl 1-Butene 5.3Methyl Formate 5Methyl Methacrylate 2.2Methyl Nitrite 2.22-Methyl Pentane 3.73-Methyl Pentane 22-Methyl 1-Pentene 5.72-Methyl 2-Pentene 3

GAS DETECTION: SPECIALTY

86 www.conceptcontrols.com

Sentry Series Open Path Multi-Gas Analyzers

Sentry MX and Sentry MDThe Sentry MX and Sentry MD are monostatic, open-path air-monitoring systems that use ultraviolet light to analyze the air for hazardous pollution and airborne toxins.

Easy to use and portable, the Sentry MX can continuously monitor one-way path lengths up to 1000 metres (a 2000 metre optical path length). The Sentry MD can continuously monitor one-way path lengths up to 400 metres (an 800 metre optical path length).

The monostatic design of the Sentry MX and Sentry MD eliminates the need for power at both ends of the path. They offer real-time detection of compounds from the parts-per-trillion to percent concentration level.

UV Sentry BX and Sentry BDThe Cerex UV Sentry BX and BD are two-part, open-path air-monitoring systems that use ultraviolet light to analyze the air for hazardous pollution and airborne toxins.

Easy to use and portable, the UV Sentry can continuously monitor path-lengths up to 1000 metres (BX) or 450 metres (BD). The UV Sentry offers real-time detections of compounds ranging in concentrations from the parts-per-billion to percent level.

Mini SentryCerex Mini Sentry Continuous Analyzers are engineered specifically for low cost, low maintenance, high performance point monitoring arrays or optional short, open path monitoring arrays. Stock models are available for ammonia, benzene and chlorine monitoring.

A direct replacement for electrochemical, PID and NDIR sensor arrays, the Mini Sentry cannot be poisoned, is unaffected by high humidity, offers ppb level detection limits, and is easily installed for long term monitoring installations.

Sentry Series open-path monitors utilize an expansive library of detectable gases for continuous monitoring, from hazardous health sites to refinery emissions. These analyzers feature software, programmable adjustment of alarm levels, and user configurable relay activated alerts for gas faults. All Sentry devices feature custom alarms, complete integration into your existing data network, and an unparalleled ease of use. Alarm outputs include 4-20mA signals and SPDT relays for fast, reliable warning. Combined with a wireless or wired network, our analyzers can relay concentration levels from remote locations to a central control station for immediate response.

All Sentry series open path multi-gas analyzers are capable of parts per trillion analysis of mercury, and parts per billion (ppb) to percent level monitoring of most other compounds.

Available Compounds for Sentry Series Analyzers:

Compound Detected Mini

MX / BX(Xenon Source)

MD / BD(Deuterium

Source)1,3 Butadiene (C4H6) ●

Acetaldehyde (C2H4O) ● ●

Acetone (CH3COCH3) ●

Acrolein (C3H4O) ●

Ammonia (NH3) ● ●

Benzene (C6H6) ● ● ●

Carbon Disulfide (CS2) ● ●

Chlorine (Cl2) ● ● ●

Chlorine Dioxide (ClO2) ● ●

Ethyl Benzene (C8H10) ● ●

Formaldehyde (CH2O) ● ●

Hydrogen Sulfide (H2S) ●

Isoprene (C5H8) ● ●

Mercury (Hg) ● ●

Naphthalene (C10H8) ● ●

Nitric Oxide (NO) ●

Nitrogen Dioxide (N2O) ●

Nitrous Acid (HNO2) ● ●

Oxygen (O2) ●

Ozone (O3) ● ●

Phenol (C6H5OH) ● ●

Styrene (C8H8) ● ●

Sulfur Dioxide (SO2) ● ●

Toluene (C6H5CH3) ● ●

Trimethylbenzene (C9H12) ● ●

O-Xylene, M-Xylene, P-Xylene (C8H10) ● ●

87www.conceptcontrols.com

CEREX PORTABLE ANALYZERS

UV 3000 Series Multi-Gas Analyzers UV 3000 and UV 3000PStack AnalyzersUV 3000 analyzers are used in process monitoring, stack monitoring, and mobile air quality laboratory applications.

Options• Cross process pipe adapters• Fast UVDOAS acqusition cycles• NEMA enclosure• Operator specific control outputs• Extended temperature

control options for extreme environments

The Cerex UV 3000 P is a fixed mount multi-gas analyzer with a flange adapted probe. Available with two ports for operator specified quality assurance audits, integrated stack temperature and humidity monitoring, and wired or wireless remote control. Continuous sample acquisition reduces latency and for many applications the sample acquisition cycle is one minute in duration.

UV 3000 F and UV 3000 XF Process and Benchtop AnalyzersUV 3000 F model analyzers are used in process monitoring, indoor air quality, and mobile air quality laboratory applications. The UV 3000 F is available with a range of fibre coupled cells, custom cross process adapters, and insitu monostatic probes. It is ideal for laboratory setups as well as closed cell process monitoring and insitu process monitoring.

Cerex UV 3000 XF model analyzers are used in laboratory, mobile, and process air quality applications. Fibre coupled cell options offer a vast range of detection limits while simultaneously ensuring separation of the main unit from the various hazards of corrosive or explosive environment monitoring.

UV 3000C Zone AnalyzerThe UV 3000C is a fixed mount multi-gas analyzer with internal sample cell. Available with an integrated twelve port multiplexer, it offers sequential zone monitoring of up to ten locations for leak detection, process monitoring or indoor air quality monitoring. Two ports are generally reserved for operator specified quality assurance audits. Continuous parallel sample acquisition reduces latency and for many applications the sample acquisition cycle is one minute.

Cerex manufactures stock and fully custom UVDOAS analyzers within the UV 3000 product series. Based around a proven UVDOAS data acquisition system, each unit is capable of harnessing our proven methods in your environment. Available in Cross Stack, Rackmount, Probe and Zone configurations, the UV 3000 series of analyzers has something for everyone.

Cerex UVDOAS analyzers accurately measure common combustion gases, BTEX, SVOC’s, chlorine, ammonia, as well as many more. All our devices feature custom alarms, complete integration into your existing data network, and an unparalleled ease of use.

Available Compounds for UV 3000 Analyzers:

Compound Detected

3000, 3000P, 3000F 3000XF 3000C

1,3 Butadiene (C4H6) ● ●

Acetaldehyde (C2H4O) ● ●

Acetone (CH3COCH3) ●

Acrolein (C3H4O) ●

Ammonia (NH3) ● ●

Benzene (C6H6) ● ● ●

Carbon Disulfide (CS2) ● ● ●

Chlorine (Cl2) ● ●

Chlorine Dioxide (ClO2) ● ●

Ethyl Benzene (C8H10) ● ● ●

Formaldehyde (CH2O) ● ● ●

Hydrogen Sulfide (H2S) ● ●

Isoprene (C5H8) ● ●

Mercury (Hg) ● ● ●

Naphthalene (C10H8) ● ● ●

Nitric Oxide (NO) ●

Nitrogen Oxide (NO) ●

Nitrogen Dioxide (N2O) ● ●

Nitrous Acid (HNO2) ●

Oxygen (O2) ● ●

Ozone (O3) ● ● ●

Phenol (C6H5OH) ● ●

Styrene (C8H8) ● ●

Sulfur Dioxide (SO2) ● ● ●

Toluene (C6H5CH3) ● ● ●

Trimethylbenzene (C9H12) ● ●

O-Xylene, M-Xylene, P-Xylene (C8H10) ● ● ●

GAS DETECTION: SPECIALTY

88 www.conceptcontrols.com

FT 5000 Series Multi-Gas Analyzers FT5000 CEM Cross Stack AnalyzersThe Cerex FT5000 is a portable Continuous Emissions Monitor for cross stack applications. It is based on proven FTIR and DOAS technology. It provides real-time multi-gas qualification and quantification of gases commonly found in stack emissions. The FT5000 can also serve as a reliable alarm and easily integrates into your existing alarm system. The Cerex FT5000 analyzer is based on the widely acclaimed full spectrum Bomem MB3000 interferometer. The MB3000 has compliance with CE and TUV.

FT5000+ Dual channel FTIR / UVDOAS Cross Stack Multi-Gas CEM Analyzer The Cerex FT5000+ is a fixed Continuous Emissions Monitor for cross stack or process applications. The system is based on proven FTIR and UVDOAS technology. It provides real-time multi-gas qualification and quantification of gases commonly found in stack emissions. The FT5000+ features simultaneous dual channel UVDOAS and FTIR operation, allowing for monitoring of gases typically impossible with a single system. It comes standard with an internal controller for data logging and integration into your existing data acquisition network. A number of output options for alarm, data, and process control are available for direct integration into your exisiting emissions control system.

FT5000 PInsitu Probe CEMs, Multi-gas FTIR Stack Analzyer

The Cerex FT5000 P is a fixed Continuous Emissions Monitor for applications requiring a stack or process probe. It provides real-time multi-gas qualification and quantification of gases commonly found in stack emissions. Multiple detector options and probe lengths are available to meet the exact requirements of the installation. The FT 5000 P can also serve as a reliable alarm and easily integrates into your existing alarm system. It is based on the widely acclaimed full spectrum Bomem MB3000 interferometer, which has compliance with CE and TUV. It comes standard with an internal controller for data logging and integration into your existing sensor network. A number of output options for alarm, data, and process control are available.

Cerex cross stack, probe based, and UVDOAS FTIR hybrid systems allow the FT 5000 Series to monitor a wide array of compounds that would typically require multiple devices. Minimal maintenance expenses, coupled with automatic calibration cycles and continuous logging and transmission of data, make the FT 5000 series perfect for your monitoring application. Cerex FTIR analyzers can easily be configured to monitor over 400 other compounds. They feature custom alarms, complete integration into your existing data network, and an unparalleled ease of use.

Available Compounds for Sentry Series Analyzers:

Compound DetectedFT 5000 & 5000P FT 5000+

Acetaldehyde (C2H4O) ● ●Acetic Acid (C2H4O2) ● ●Acetone (CH3COCH3) ● ●Acetylene (C2H2) ● ●Acrolein (C3H4O) ● ●Ammonia (NH3) ●Benzaldehyde (C7H6O) ● ●Benzene (C6H6) ●Butane (C4H10) ● ●n-Butyl (C6H12O2) ● ●Carbon Dioxide (CO2) ● ●Carbon Disulfide (CS2) ●Carbon Monoxide (CO) ● ●Chlorine (Cl2) ●Chlorine Dioxide (ClO2) ● ●Ethane (C2H6) ● ●Ethanol (C2H6O) ● ●Ethyl Benzene (C8H10O) ● ●Formaldehyde (CH2O) ●Formic Acid (CH2O2) ● ●n-Hexane (C6H14) ● ●Hydrogen Bromide (HBr) ● ●Hydrogen Chloride (HCl) ● ●Hydrogen Fluoride (HF) ● ●Hydrogen Sulfide (HS) ●Isoprene (C5H8) ●Mercury (Hg) ●Methane (CH4) ● ●Napthalene (C10H8) ●Nitric Oxide (NO) ● ●Nitrogen Dioxide (N2O) ● ●Nitrous Acid (HNO2) ●Oxygen (O2) ●Phenol (C6H5OH) ● ●Phosgene (CCl2O) ● ●Styrene (C8H8) ●Sulfur Dioxide (SO8H8) ●Toluene (C6H5CH3) ●Trimethylbenzene (C9H12) ●Water Vapor (H2O) ● ●O-Xylene, M-Xylene, P-Xylene (C8H10) ●O-Xylene, M-Xylene, P-Xylene (C8H10) ●

89www.conceptcontrols.com

ENVIRONMENTAL SURVEY/PURGING MONITORS

ENvIRONmENTAL SuRvEY/PuRgINg mONITORS

RKI Eagle 2RKI is proud to offer the next generation of our popular Eagle portable gas detector. Equipped with features that are not available on competitive units, the Eagle 2 is a powerful instrument that does more than just offer the standard confined space protection for LEL, O2, H2S and CO.

Features:• Monitor up to 6 autoranging gases• PPM / LEL hydrocarbon detection• PID (photoionization detector) low and

high range for VOC detection• Infrared Sensors available: CO2, % LEL

CH4, % Vol. CH4, % LEL HC, % Vol. HC• TC (Thermal Conductivity) sensors

available: % Vol. H2 or % Vol. CH4• Plug and play, smart toxic sensors• Displays in 5 languages• Powerful long-life pump up to 125’ range• Low flow pump shut off and alarm• Methane elimination for environmental use• Alkaline 18 hours or Ni-MH 20 hours capability• Password protection• Datalogging standard• IrDA communications port• Autocalibration/single gas calibration• Internal hydrophobic dust filter• External probe with hydrophobic filter

RENTAL

VRAE

VRAE is a hand held one-to-five gas monitor with built-in sampling pump and optional data logging.

Sensors include new RAE dual range 0-100% volume and 0-100% LEL, oxygen, and three or four smart, interchangeable toxic sensors may be added.

The internal pump automatically shuts off and an alarm is activated if the remote probe tubing crimps or liquid is sucked onto the field-replaceable filter.

Features:• 16,000 data points download to PC • Snap-in, field replaceable, rechargeable

battery with up to 10 hours of continuous operation

• Protected from portable radios • Internal sample draw pump for quick

response and remote sampling • Smart battery charging with status

indication and LED indicator

RENTAL AreaRAE

The AreaRAE is a one-to-five sensor gas detector equipped with a built-in, wireless RF (radio frequency) modem that allows the unit to communicate and transmit readings and other information on a real-time

basis with a remotely located base controller. It is a multi-sensor instrument that can include a Photoionization detector (PID) for parts-per-million measurement of volatile organic compounds (VOCs), a gamma radiation detector, an LEL, O2 sensor ,and up to two electrochemical toxic gas sensors for measurement of specific toxic substances such as CO and H2S.

AreaRAE is approved for use in Class I Division 2 hazardous environments. A personal computer with ProRAE Remote is the base station for an AreaRAE system. The standard ProRAE Remote software used to control AreaRAE systems is capable of monitoring the input of up to 32 remotely located monitors. AreaRAE monitors can be equipped with optional GPS capability allowing users to know the exact location of the monitor.

Monitor-only includes:• Monitor as specified• Carbon filters (for units with CO)• Calibration adapter• Quick reference guide• Operation and maintenance manual• Shoulder strap• Rechargeable Lithium-ion battery

pack• 120/240 VAC AC/DC adapter• Spare alkaline battery pack• 10 spare external filters• Hard transport case with

pre-cut foam• 15’ (5 m) Teflon tubing• Tool kit

AreaRAE Steel shown with optional stand

Wireless, Multi-channel, Compact and Easily Transportable Multi-Gas monitor

RENTAL WIRELESS

NEW

Concept Controls Inc.

GAS DETECTION: SPECIALTY

90 www.conceptcontrols.com

Utilizing the exclusive ChemKey Gas Selection System, a single monitor is capable of monitoring over 50 different gases with just a change of ChemKey and Chemcassette. As with all Chemcassette based products, you are assured of fast, sensitive and substance specific exposure protection. There is never any danger of false alarms or inaccurate results caused by other commonly present chemicals.

ChemKeyTM TLV

Advantages• Portable, flexible and

interference free toxic gas detection

• Battery operated or line powered

• Exclusive Chemcassette® detection is gas specific, sensitivity to ppb levels with physical evidence

Detectable Gases Range Amines

Ammonia (NH3)* 2.6-75.0ppm

Ammonia (NH3)-II 2.6-75.0ppm

Methylene Dianiline (MDA) 3-60ppb

n-Butylamine (n-BA) 0.4-12.0ppm

p-Phenylene Diamine (PPD) 2-60ppb

Toluene Diamine (TDA) 4-60ppb

Trimethylamine (TMA) 1.1-30.0ppm

Diisocyanates Range

CHDI, HDI, HMDI, IEM, IPDI, MDI, NDI, PPDI, TDI, TMDI, TMXDI, XDI

2-60ppb

Hydrazines

MMH* 21-600ppb

N2H4 20-300ppb

UDMH* 53-1500ppb

Hydrides

Arsine (AsH3) 15-150ppb

Diborane (B2H6) 31-300ppb

Disilane (Si2H6) 1.5-15ppm

Germane (GeH4) 141-600ppb

Hydrogen Selenide (H2Se) 20-150ppb

Phosphine (PH3) 32-900ppb

Silane (SiH4) 0.5-15ppm

Stibine (SbH3) 20-300ppb

tert-Butylarsine (TBA) 15-150ppb

tert-Butylphosphine (TBP) 60-900ppb

Hydrogen Cyanide (HCN)* 1.1-30.0ppm

Hydrogen Sulfide (H2S) 1.1-30.0ppm

Hydrogen Sulfide (H2S) Low Level 1-90ppb

Mineral Acids

Hydrogen Bromide (HBr) 0.3-9.0ppm

Hydrogen Chloride (HCl) 0.5-15.0ppm

Hydrogen Fluoride (HF) 0.6-9.0ppm

Nitric Acid (HNO3) 0.2-6.0ppm

Sulfuric Acid (H2SO4)* 26-750ppb

Oxidizers

Bromine (Br2) 11-300ppb

Chlorine (Cl2)* 0.1-3.0ppm

Chlorine (Cl2)-II 0.5-1.5ppm

Chlorine Dioxide (ClO2) 11-300ppb

Hydrogen Peroxide (H2O2) 0.1-3.0ppm

Nitrogen Dioxide (NO2) 0.3-9.0ppm

Ozone (O3) 31-300ppb

Phosgene (CoCl2) 11-300ppb

Sulfur Dioxide (SO2) 0.2-6.0ppm

* other ranges available

ChemcassetteThe Chemcassette® detection system is the heart of an MDA toxic gas monitoring system. Chemcassettes use a dry reagent medium to collect and analyze air to detect gas leaks. When the Chemcassette® is exposed to a target gas, it changes colour in direct proportion to the concentration of gas present.

SPMThe SPM´s standard weather-proof enclosure will withstand the rigors of outdoor operation. A purged enclosure is optional for hazardous areas. You can also specify the SPM with heating and cooling options to match your environmental requirements.

Call us for ordering information

Concept Controls Inc.

91www.conceptcontrols.com

SPECIALIZED GAS DETECTION

SPECIALIZED gAS DETECTION

Gem5000The GEM5000 is the next generation in the GEM Series of instruments for accurate measurement and monitoring of landfills.

Features:• Measures % CH4, CO2 and O2 volume, static pressure and

differential pressure• Calculates balance gas, flow

(SCFM) and calorific value (KW or BTU)

• High accuracy and fast response time

• Lighter and more compact• Certified intrinsically safe• Calibrated to ISO/IEC 17025• 3 year warranty

Benefits:• Designed specifically for use on

landfills to monitor landfill gas (LFG) extraction systems, flares, and migration control systems

• No need to take more than one instrument to site• Can be used for monitoring subsurface migration probes

and for measuring gas composition, pressure and flow in gas extraction systems

• The user is able to set up comments and questions to record information at site and at each sample point

• Ensures consistent collection of data for better analysis• Streamlined user experience reduces operational times

Specifications:Gases MeasuredCH4 By dual wavelength infrared cell w/ reference channel

CO2 By dual wavelength infrared cell w/ reference channel

O2 By internal electrochemical cell

CO By internal electrochemical cell

H2S By internal electrochemical cell

RangesCH4 0-100% (vol)

CO2 0-25% (vol)

O2 0-100% (vol)

CO 0-2000ppm***

H2S 0-500ppm***

Gas Accuracy*CH4 0-5% ± 0.3% (vol) 0-70% ± 0.5% (vol) 70-100% ± 1.5% FS

CO2 0-5% ± 0.3% (vol) 0-60% ± 0.5% (vol) 60-100% ± 1.5% FS

O2 0-25% ±1.0% (vol)

CO 0-2000ppm ± 1.0% FS

H2S 0-500ppm ± 2.0% FS

* Typical accuracy after calibration as recommended in the operations manual

** Hydrogen compensated carbon monoxide measurement*** Additional ranges available, contact us for more information

G100 CO2 Incubator AnalyzerThe new G100 CO2 analyzer is specifically designed to monitor CO2 for the verication of incubators in IVF, medical, research and other pharmaceutical applications. It incorporates the latest technology and specifications requirements, providing the user with a fast, simple-to-use and accurate piece of the laboratory kit.

Features:• CO2 0 – 20%• Options for:

• O2 0 – 100%• Dual temperature probes

32°F – 122°F (0°C – 50°C)• Data storage and download• Humidity sensor 0 – 100%

Benefits:• Improved accuracy on CO2 readings• Quick verification of CO2 incubator

levels• Time saving with dual

temperature probes• Large data storage with

software• Easy to read, large, well-lit display• Built in gas moisture removal

NEW

G110 CO2 AnalyzerThe G110 CO2 analyzer is designed to monitor CO2 for multiple applications including the brewing industry. It has been developed using the latest technology and specifations requirements, providing the user with a fast, simple-to-use analyzer.

Features:• CO2 0 – 100%• Options for:

• O2 0 – 100%• Dual temperature probes

32°F – 122°F (0°C – 50°C)• Humidity Sensor 0 – 100%• Data storage and download

Benefits:• Improved accuracy on CO2

readings• Quick verification of CO2 levels• Time saving with dual

temperature probes• Large data storage with software• Easy to read large well-lit

display• Built in gas moisture removal

Applications:• IVF• Research • Laboratories • Medical

Applications:• Food Processing• Research• Brewing• Medical

RENTAL

GAS DETECTION: SPECIALTY

92 www.conceptcontrols.com

G150 CO2 Indoor Air Quality AnalyzerThe G150 CO2 Analyzer is designed to monitor CO2 for all indoor air quality applications. It was developed using the latest technology and specifications requirements, providing the user with a fast, simple to use, and accurate piece of the environmental field kit.

Features:• CO2 0 – 10,000 ppm• Options for:

• O2 0 – 100%• Dual temperature probes

32°F – 122°F (0°C – 50°C)• Data storage and download• Humidity sensor 0 – 100%

Benefits:• Improved accuracy on CO2

readings• Quick verification of CO2 levels

for site audits• Time saving with dual

temperature probes• Large data storage with software• Easy to read, large, well-lit display• Built in gas moisture removal

G210 N2O 0-100% Gas AnalyzerThe G210 is specifically designed for highly accurate measurement and verification of the quality of piped N2O and O2 medical gases in hospitals.

Features:• 0 – 100% N2O• 0 – 100% O2• 0 – 500 ppm CO (optional)• 0 – 2,000 ppm CO2• Data storage with site & ID

input• User alarms

Benefits:• 4 gases measured in one

analyzer• Easy user calibration• Quick verification of gas quality• Enter specific site & IDs for

monitoring points• Identify contaminants CO and

CO2

Applications:• Hospital piped gases• Leak detection

Applications:• General IAQ• Site Audits• Laboratories • Medical

G200 N2O 0-1,000 ppm Gas AnalyzerThe G200 N2O analyzer is designed to safety check background and breathing zone levels of N2O (0–1,000ppm).

Features:• 0 – 1,000 ppm N20• Storage for 1000 readings• TWA calculated• Leak detection• User settable alarms• Data download for graphing

and reporting

Benefits:• Accurate verification of

exposure limits• Dual purpose background

analyzer or personal analyzer• Leak detection for N2O storage• Highly portable

Applications:• Operating Rooms• Dental Practices• Veterinary Clinics• X-ray Departments

The TVA-1000B is the only over the shoulder portable vapour analyzer that offers both PID (Photoionization Detection) and FID (Flame Ionization Detection). Users can measure a wide variety of organic vapours over an impressive dynamic range (0-50,000 ppm). The FID operates by breaking hydrogen-carbon bonds and is not limited by the ionization potential of the molecule.

Features:• Dual simultaneous FID/PID or

single FID detectors• Portable and

lightweight• Multiple response

factors and curves• Multi-point

calibration• Eight

programmable location labels

• On-board datalogging

Thermo Scientific TVA-1000B Portable FID/PID

FLAmE IONIZATION DETECTORS