INFRASTRUCTURE
FROM DESIGN TO START UP
SAFETY FEATURES OF AKAR AUTOCLAVES
MEDICAL WASTE STERILIZATION SYSTEMS
WHAT IS STERILIZATION?
STERILIZATION SYSTEMS
PRE-SHREDDED SYSTEMS
POST-SHREDDED SYSTEMS
SHREDDERS
SAMPLE 3D VIEWS
SAMPLE LAYOUT
QUALITY CERTIFICATES
4
5
6
7
8
9
10
12
15
17
18
19
2
INDEX
ABOUT US
QUICK FACTS
Pressure Equipment Directive 97/23/EC (PED) Simple Pressure Vessels Directive 2009/105/EC (SPVD) ASME SEC VIII Div. 1 GOST - R EN 3834-2 EN 15085-2 Other certificates that may be required by different countries and jurisdictions
To certify our autoclaves, we work with internationally well-known certificate agencies such as BureauVeritas, TUV, Hartford Steam Boilers.
Thank you for your interest in our company and our products. We look forward to realizing successfulprojects with you, and enhancing your value chain with our high quality products.
Location: Eskisehir, Turkey – conveniently located close to ports and major cities Factory: 19,000 m2 factory space in Eskisehir Industrial Zone ISO 9001 – 2000 certified with advanced engineering capabilities Professional management with well executed future growth plans For more information, please visit us at www.akarmak.com.tr and www.autoclave.com.tr
Akar Makina, founded in 1990, manufactures autoclaves, machines and pressure vessels for variousindustries including Composite Materials, Glass, Tire Retreading - Rubber Vulcanization, Building Materials, and Medical Waste Sterilization. Medical waste sterilization (MWS) systems are manufactured in our state-of-the-art manufacturing facilities in the city of Eskisehir, with close proximity to major cities and ports. From the customer requirement acquisition stage to design, manufacturing, test, delivery and on-site commissioning, Akar is capable of providing turn-key and boutique solutions for every customer need. Akar is the only company in the world that has technologies for both pre-shredded and post-shredded MWS systems. The systems are designed using advanced design tools and software meeting the highest safety andquality standards. We approach every project as unique and custom-made, and can handle customerspecific requests. The MWS Systems are manufactured with limited reliance on outside suppliers and arecarried out by an experienced, highly trained and certified work force and technical staff.
Akar has the following certifications including those for autoclave and pressure vessel manufacturing:
3
MAIN FACTORY
Address: OSB 14. Cadde No: 8 Eskisehir, TURKEY - www.akarmak.com.tr/www.autoclave.com.tr
SECOND FACTORY
Address: OSB 8. Cadde No: 27 Eskisehir, TURKEY - www.akarmak.com.tr/www.autoclave.com.tr
INFRASTRUCTURE
4
SAFETY FEATURES OF AKAR AUTOCLAVES
Safety is critical when it comes to autoclaves, and by manufactured according to accepted standards, Akar’s autoclave systems’ safety is guaranteed by the following:
Material is specially used for pressure vessels. Safety switches used at the door system showing the door as open/closed and locked Advanced PLC control system controlling maximum and minimum pressure values through PLC Mechanical over pressure valve system Manufactured according to 97/23/EC Pressure Equipment Directives (PED) or ASME or GOST-R standards Manufactured according to 98/37/AT Machinery Safety Regulation Manufactured according to CE (Europe), ASME (North America), GOST-R (Russia) standards Certified autoclaves by world well-known certification agencies such as Bureau Veritas, TUV, Hartford Steam Boilers etc. 10 year safety guarantee as part of CE
6
An autoclave is a commonly used method for heat sterilization. Autoclaves normally use steam heated to 121–134 °C (250–273 °F). To achieve sterility, a holding time of at least 15 minutes at 121 °C (250 °F) or 3 minutes at 134 °C (273 °F) is required. Additional sterilizing time is usually required for liquids and instruments packed in layers of cloth, as they may take longer to reach the required temperature (not necessary in machines that grind the contents prior to sterilization). Following sterilization, liquids in a pressurized autoclave must be cooled slowly to avoid boiling over when the pressure is released. Modern autoclaves avoid this problem by gradually depressing the sterilization chamber and allowing liquids to evaporate under a negative pressure, while cooling the contents. Proper autoclave treatment will eliminate all fungi, bacteria, viruses and also bacterial spores, which can be quite resistant. It will not necessarily eliminate all prions. For prion elimination, various recommendations state 121–132 °C (250–270 °F) for 60 minutes or 134 °C (273 °F) for at least 18 minutes. The prion that causes the disease scrapie (strain 263K) is inactivated relatively quickly by such sterilization procedures; however, other strains of scrapie, as well as strains of CJD and BSE are more resistant. For a significant margin of safety, cleaning should reduce infectivity by 4 logs, and the sterilization method should reduce it a further 5 logs. To ensure the autoclaving process is able to cause sterilization, most autoclaves have meters and charts that record or display pertinent information such as temperature and pressure as a function of time. Indicator tape is often placed on packages of products prior to autoclaving. A chemical in the tape will change color when the appropriate conditions have been met. Some types of packaging have built-in indicators on them. Biological indicators ("bioindicators") can also be used to independently confirm autoclave performance. Simple bioindicator devices are commercially available based on microbial spores. For effective sterilization, steam needs to penetrate the autoclave load uniformly, so an autoclave must not be overcrowded, and the lids of bottles and containers must be left ajar. Alternatively steam penetration can be achieved by shredding the waste in some autoclave models that also render the end product unrecognizable. During the initial heating of the chamber, residual air must be removed. Indicators should be placed in the most difficult places for the steam to reach to ensure that steam actually penetrates there. For autoclaving, as for all disinfection or sterilization methods, cleaning is critical. Extraneous biological matter or grime may shield organisms from the property intended to kill them, whether it physical or chemical. Cleaning can also remove a large number of organisms. Proper cleaning can be achieved by physical scrubbing. This should be done with detergent and warm water to get the best results. When cleaning instruments or utensils with organic matter, cool water must be used because warm or hot water may cause organic debris to coagulate. Treatment with ultrasound or pulsed air can also be used to remove debris.
Source: Wikipedia
WHAT IS STERILIZATION?
8
9
STERILIZATION & SHREDDER TECHNOLOGIES
SHREDDERS
LARGE CAPACITY MWS SYSTEMS
SMALL CAPACITY MWS SYSTEMS (Useful for
small cities and hospitals)
AKR 300 L300 kg/h
AKR 500 A500 kg/h
AKR 1000 A1000 kg/h
AKR 1500 A1500 kg/h
AKR 50 L50 kg/h
AKR 100 L100 kg/h
AKR 500 L500 kg/h
AKR 750 L750 kg/h
AKR S R/2 290500-1000 kg/h
AKR S R/2 3501500-2000 kg/h
AKR S C/2 200300-500 kg/h
AKR S C/2 290500-1000 kg/h
AKR S C/2 3501200-1700 kg/h
POST-SHREDDEDMWS SYSTEMS
PRE-SHREDDED MWS SYSTEMS
AKAR MEDICAL WASTE STERILIZATION SYSTEMS LIST AKAR MEDICAL WASTE STERILIZATION SYSTEMS LIST
10
Sterilization Capacities (kg/h)
Stainless-steel AISI 316 L
Bureau Veritas
Full Automatic, Pre-shredding, Pressured, Steam Sterilization
Full Automatic Including Lifter, Container Feeding System
Full Automatic (Loading is manual), Pre-shredding, Pressured,
Steam Sterilization
Manual loading with waste bags
300
7.500
1.500
1.000
Hydraulic
60
4700x4500x6500
1x22KW & 1x15KW
Bayonet
500
10.000
1.500
1.500
Hydraulic
60
4700x5000x6500
1x22KW & 1x15KW
Bayonet
750
12.500
1.500
2.000
Hydraulic
60
4700x6500x6500
1x22KW & 1x15KW
Bayonet
50
2.500
150
150
Pneumatic
30
2000x1500x3000
1x7,5KW & 1x5KW
Bayonet
-
-
100
2.800
150
250
Pneumatic
30
2500x1500x3000
1x7,5KW & 1x5KW
Bayonet
-
-
Process Method
Pressure Vessel and Shredder Hopper Materials
Pressure Vessel and CE Certi�cations
Total Weights with Steel Structures (except steam boiler and compressor) (kg)
Feeding Unit’s Volume (lt)
Sterilization Vessel’s Volume (lt)
Waste Feeding System
Feeding, Discharging Door System's Opennig/Closing, Locking/Unlocking
Total Design Power (Excluding Steam Generator and Compressor) (kw)
Dimensions (Width x Length x Height) (mm)
Shredder's Electric Motor Power
Feeding, Discharging Door Design Method
Automatic Weight System
Shredder Type : Double Axle, Separated gearbox for each axle
Programmable Auto Reverse Control System for Shredder
Waste Mixing and Discharging System : Archimedes Screw (Hardox 500)
Sterilization Temperature : 135-140 C
Sterilization Pressure : 3-5 bar (Programmable)
Vacuuming : Venturi System or Vacuum Pump
PLC & Automation System : Siemens S7/300, Touch Panel, Simatic Software,
Programme Uploads and Long Distance Remote System with Internet Connection
Monitorization, Report Data Saving: Coloured Display, Turkish or English Menu
Data Save and Print-out System for Reporting
2” Double Condensate Discharge
CE Certi�ed
TECHNICAL FEATURES AKR 50 L AKR 100 L AKR 300 L AKR 500 L AKR 750 L
PRE-SHREDDED SYSTEMS
AKAR MEDICAL WASTE STERILIZATION - PRE-SHREDDED SYSTEMS DATA
11
PRE-SHREDDED MEDICAL WASTE STERILIZATION SYSTEM FLOW CHART
STOP THEARCHIMEDES
SCREW
CLOSE THE TOP DOOR AND LOCK IT
VACUUMING AND AIR DISCHARGING
FINISH THE STERILIZATION
OPEN THE FRONT DOOR
WASTE DISCHARGING
CLOSE THE FRONT DOOR
PROCESS FINISH
PRESSURE AND TEMPERATURE REACHED THE PROGRAMMED
VALUES
N
N
N
Y
Y
Y
RESET
TROUBLESHOT
CHECK THE SWITCHES
OPEN THE TOP DOOR
PROCESS START
CONTAINER LOADING TO LIFT
LIFT UP
IS TOP DOOR OPEN?
FINISH THE WASTE LOADS
START THE SHREDDING
FINISH THE SHREDDING
START THE ARCHIMEDES
SCREW
DOSE THE CURRENT MOTOR
EXCEED THE NOMINAL VALUE?
IS THE PLANNED CHARGE
REALIZED?
12
POST-SHREDDED SYSTEMS
Medical waste sterilization system with pre and post shredded autoclave methodsVarious hourly capacity sterilization systems based on specific customer needsFull automatic and advanced automation control system with pressured direct steam sterilizationAdvanced reporting and monitoring featuresHigh standard of sterilization meeting requirements by regulationsTurnkey solutions including shredders, autoclave trolleys, steam generators, air compressor systemsSpecial gasket system for perfect vacuum and pressure conditionsMultiple point safety control devices and built with highest safety standardsDesign and manufacturing based on international standards including CE, ASME, GOST-R
13
TECHNICAL FEATURES
Sterilization Capacities (kg/h)
P295GH
Bureau Veritas
Full Automatic, Post-shredding, Pressured, Steam Sterilization
1.000
12.500
20.000
1.500
15.000
26.000
500
10.000
14.000
Process Method
Autoclave Material
Pressure Vessel and CE Certi�cations
Total Weights (Autoclave with shredding system, except steam boiler and compressor) (kg)
Sterilization Vessel’s Volume (lt)
Full Automatic Including Lifter, Covered with transparent fences, Container Feeding System
Full Automatic, Hydraulic closing/opening, hydraulic locking/unlocking
60 kW
Waste Feeding System into Shredder's hopper
Autoclave Door System
Total Design Power (Excluding Steam Generator and Compressor)
Autoclave Inner Dimensions (Width x Length x Height) (mm)
Autoclave Cars (mm) 1200x1200x1200
Ø2.000 x 4.000 Ø2.000 x 6.500 Ø2.000 x 8.500
Autoclave Car Material AISI 316 L
Autoclave Car Quantity for Cycle 3 5 7
Door Designation Bayonet Bayonet Bayonet
Shredding System Feeding Hopper Capacity (lt) 2.000 2.000 2.000
Shredder Gearbox Power 1 x 22 KW & 1x 15 KW 1 x 22 KW & 1x 15 KW 1 x 22 KW & 1x 15 KW
Shredding System Waste Loading
Compressor Capacities (bar - m3/min) 8 - 2,5
Full Automatic, Lifter, Manual Car Loading
Shredding System Space Dimensions (mm) 5300 x 5300 x 7040
Steam Boiler Capacities (kg/h) 1.000 1.500 2.000
Optimum Building Area Needs (mm) 15.000 x 15.000 x 8.000 18.000 x 15.000 x 8.000 20.000 x 15.000 x 8.000
Sterilization Temperature : 140-155 C
Data Save and Print-out System for Reporting
2” Double Condensate Discharge
CE Certi�ed
Sterilization Pressure : 3-5 bar (Programmable)
Vacuuming : Water Jacket Vacuum Pump
PLC & Automation System : Siemens S7/300, Touch Panel, Simatic Software,
Programme Uploads and Long Distance Remote System with Internet Connection
Monitorization, Report Data Saving: Coloured Display, Turkish or English Menu
Shredded Waste Size (length - width) (mm) 100 x 30
Automatic Lifting for Autoclave Loading and Weight Control
Shredder Type : Double Axle, Separated gearbox for each axle
Programmable Auto Reverse Control System for Shredder
AKR 500 A AKR 1000 A AKR 1500 A
AKAR MEDICAL WASTE STERILIZATION - POST-SHREDDED SYSTEMS DATA
N
N
N
N
N
YY
Y
Y
Y
Y
Y
Y
14
POST-SHREDDED MEDICAL WASTE STERILIZATION SYSTEM AUTOCLAVE FLOW CHART
STEAM DISCHARGING
DID PRESSURE REACHED "0"?
PRESSURE REACHED "0"?
START HYDRAULIC MOTOR
UNLOCK THE DOOR
OPEN THE DOOR
UNLOAD THE CONTAINER
VACUUMING IS ON
PROCESS FINISH
PROCESS START
DOES AUTOCLAVE DOOR OPEN?
CONTAINER LOADING
CLOSE THE DOOR
LOCK THE DOOR
DOES LOCKING CENSOR ON?
VACUUMING IS ON
DIDVACUUM REACHED
500 mbar?
STOP VACUUMING
CLOSE THE VACUUM VALVE
OPEN THE STEAM VALVE
DID TEMPERATUREAND PRESSURE REACHED
PROGRAMMED VALUES?
OPENTHE DOOR
STERILIZATION STEP
WATER DICHARGING
STEAM DISCHARGING
COOLING STEP
VACUUMING
DID TEMPERATURE REACHED TO
PROGRAMMED VALUE?
UNLOCK THE DOOR
CHECK THE CENSOR
16
AKAR MEDICAL WASTE STERILIZATION SYSTEMS - SHREDDERS
Frame Type Rectangular, Assembled frames, Material is steel Circular, Assembled frames, Material is stainless-steel
Frame Material S275 JR S275 JR AISI 316 L AISI 316 L AISI 316 L
Shredding Capacities (kg/h) 500-1000 1500-2000 300-500 500-1000 1200-1700
Weight (without gearboxes) (kg) 1300 3000 650 2000 2600
Working Pressure (bar) 0 4
Working Temperature ( ˚C ) 0-70 0-140
Outer Dimensions (mm) 500 x 1030 x 1015 600 x 1437 x 1130 Ø800 x 400 Ø1350x 490 Ø1350 x 600
Inner Dimensions (mm) 800 x 800 1007 x 900 520 x 480 750 x 850 740 x 856
Cutter Dimensions (mm) Ø260 x 30 Ø350 x 30 Ø260 x 30Ø260 x 25 Ø350 x 30
Number of Cutter Teeth 6 8 6 6 8
Cutter Material S275JR hardened
Cutter Hardness ( HRC) 45 HRC
Total Cutter Number for a Shredder 25 33 18 25 28
Axle Center's Dimension (mm) 205 295 205 295
Axle Diameter (mm) Ø115 (Chrome coated) Ø140 (Chrome coated) Ø90 (Chrome coated) Ø115 (Chrome coated) Ø140 (Chrome coated)
Bearings SKF–22226 E (4 pcs) SKF–T2 222 14 (4 pcs) SKF–222 17 (4 pcs) SKF–22226 E (4 pcs)SKF–222 17 (4 pcs)
Lubricant Neogrease HT S2 Neogrease HT S2 Neogrease HT S2 Neogrease HT S2 Neogrease HT S2
Connection Screws to Pressure Vessels - - M16 (20 pcs) M16 (24 pcs) M16 (20 pcs)
Connection Screws to Hoppers M16 (22 pcs) M16 (22 pcs) - - -
Electric Motor Power (kw) 22 + 15 5,5 + 5,5 22 + 15
Gearbox Outlet rpm 22 & 15
Shredded Waste Size (mm) 30 x 100
TECHNICAL FEATURESRECTANGULAR FRAMES / 2 AXLES
AKR S R/2 290 AKR S R/2 350 AKR S C/2 200 AKR S C/2 290 AKR S C/2 350
CYLINDRICAL FRAMES / 2 AXLES
Akar Makina Sanayi Ltd. OSB 14. Cadde No: 8 26110 Eskisehir / TURKEY
Phone: +90 222 236 17 00 Fax: +90 222 236 17 02 E-mail: [email protected]
www.autoclave.com.tr www.akarmak.com.tr