Enviro‐Equipment Inc. 10120 Industrial Drive Pineville NC 28134
Serial# EEI‐1322 Dimensions: 7x14’ Trailer with 7,000lb GVWR Description: AS‐SVE Trailer *****SVE EQUIPMENT***** Rotron EN656 3HP 1PH XP Blower 2" Kunkle Vacuum Relief Valve 2" Solberg Vacuum Air Filters with vacuum gauges, Dilution Filter Silencer, and Discharge Silencer 60 Gallon Aluminum KO Tank with Sight Glass and 3 Level Float Tree Myers CT Series Transfer Pump 1/2HP 1PH XP with 1" Mechanical Totalizer and pipe stub through wall with camlock connection Exhaust Flow Meter, Temperature and Pressure Gauge and Recirculation Gate Valve for Oxidizer Flow Control Interconnecting SCH 80 PVC and Galvanized Steel Piping for SVE and Transfer Pump Carbon or Oxidizer VCV Loop with Isolation Valves and Camlock Hoses 6x 2" Manifold Legs each with ball valve, vacuum gauge connection, sample port, anemometer port, pipe stub through trailer wall with camlock connection *****AIR SPARGE EQUIPMENT***** Rietschle DTA 60 with 5HP 1PH XP Motor High Temperature and Pressure Switches (Div 2) Pressure and Temperature Gauges on Main Air Sparge Line Interconnecting Galvanized Steel Piping for Air Sparge Compressor and Heat Exchanger 1" Blow Off Line with Brass Gate Valve and Muffler 6 Zone 1/2" Galvanized Manifold Each Leg with Gate Valve, Pressure Gauge, Rotameter, Pipe Stub Through Wall with Camlock connection *****ENCLOSURE***** 7x14 Enclosed Cargo Trailer with Tandem 3500lb Axles, Rear Double Door, Insulated Ceiling/Walls, D Rings Welded to Frame, Spare Tire 1" Thick Polydamp Foam on Interior Walls and Ceiling Sheet Metal Rain Hoods lined with 1" Thick Polydamp Foam for 2x Intakes Vents, 1x Exhaust Fan 2x XP Light Fixtures with Common XP Light Switch 12" XP Exhaust Fan with XP Thermostat and Finger Guard XP Heater with XP Thermostat Interconnecting Electrical ‐ Inside Trailer Class 1 Div 2 Group D, Control Panel mounted on trailer exterior over tongue general industrial weatherproof installation
Enviro‐Equipment Inc. 10120 Industrial Drive Pineville NC 28134
*****CONTROL PANEL***** 240V 1PH ‐ Requires Neutral Non Fused Disconnect Nema 4 Enclosed With Lockable Blank Front, Controls On Inner Swing Door Circuit Breaker, Contactor, Overload, HOA Switch, Hour Meter for AS, SVE, Transer Pump and Heat Exchanger Motors Circuit Breakers for all trailer fixtures (lights, fan, heater) White Control Power Light Red Lights for Each Alarm Condition Emergency Stop and Reset Push Buttons Control Transformer Control Relays Surge and Phase Protection Sensaphone Sentinel 4G LTE Telemetry System UL 508 / 698 Listing
C-13
EN 656 & CP 656Sealed Regenerative Blower w/Explosion-Proof Motor
BLOWER PERFORMANCE AT STANDARD CONDITIONSAIR FLOW RATE (M3/MIN)
INC
HE
S O
F W
AT
ER
PS
IG
MM
OF
WA
TE
R
PRESSURE▲-MAX PRESSURE
POINT
AIR FLOW RATE (SCFM)
AIR FLOW RATE (M3/MIN)
INC
HE
S O
F M
ER
CU
RY
AIR FLOW RATE (SCFM)
1.0 2.0 6.0
0 25 75 125 175 225
1.0
2.0
50 100 150 200
60 Hz50 Hz
250
3.0 4.0 5.0
INC
HE
S O
F W
AT
ER
MM
OF
WA
TE
R
SUCTION▲-MAX PRESSURE
POINT
1.0 2.0 6.0
0 25 75 125 175 225
1.0
2.0
50 100 150 200
60 Hz
50 Hz
250
3.0 4.0 5.0
MO
TO
RW
IND
ING
TE
MP
RIS
E °
C
PO
WE
RIN
PU
TW
AT
TS
BL
OW
ER
AIR
TE
MP
RIS
E °
C
MO
TO
RW
IND
ING
TE
MP
RIS
E °
C
PO
WE
RIN
PU
TW
AT
TS
BL
OW
ER
AIR
TE
MP
RIS
E °
C
100
75
50
25
100
75
50
25
50004000300020001000
75
50
25
0
50004000300020001000
75
50
25
0
80
60
40
20
2000
1500
1000
500
-80
-60
-40
-20
2000
1500
1000
500
▲
▲
▲▲
▲
▲
▲
▲A-3 HP (3 phase) B-3 HP (1 phase)
A-3 HP (3 phase) B-3 HP (1 phase)
A
B
A
BA
A
BB
FEATURES• Manufactured in the USA – ISO 9001 compliant• Maximum flow: 212 SCFM• Maximum pressure: 70 IWG• Maximum vacuum: 70 IWG• Standard motor: 3.0 HP, explosion-proof• Cast aluminum blower housing, cover, impeller &
manifold; cast iron flanges (threaded); teflon lip seal• UL & CSA approved motor with permanently
sealed ball bearings for explosive gas atmospheres Class I Group D minimum
• Sealed blower assembly• Quiet operation within OSHA standards
MOTOR OPTIONS• International voltage & frequency (Hz)• Chemical duty, high efficiency, inverter duty
or industry-specific designs• Various horsepowers for application-specific needs
BLOWER OPTIONS• Corrosion resistant surface treatments & sealing options• Remote drive (motorless) models• Slip-on or face flanges for application-specific needs
ACCESSORIES (See Catalog Accessory Section)• Flowmeters reading in SCFM• Filters & moisture separators• Pressure gauges, vacuum gauges & relief valves• Switches – air flow, pressure, vacuum or temperature• External mufflers for additional silencing• Air knives (used on blow-off applications)• Variable frequency drive package
Rev. 2/04
AMETEK Technical and Industrial Products, Kent, OH 44240 • e mail: [email protected] • internet: www.ametektmd.com
ROTRON Regenerative Blowers
SectionC 2004.qxd 6/26/04 10:53 AM Page C-13
Specifications subject to change without notice. Please consult your Local Field Sales Engineer for specification updates.
C-14
15.17384.6
L
14.14105.2
5.510129.5
15.12384.5
Ø .62015.7
(4X) MTG HOLES
STANDARDDIRECTIONOF ROTATION
15.42391.7
6.96176.8
7.46189.5
2.0552.1
7.19182.6
5.38136.7
.6416.3
4.92125
11.420290.1
12.81325.4
2" NPSCSTRAIGHTTHREADSBOTH PORTS
A
EN 656 & CP 656Sealed Regenerative Blower w/Explosion-Proof Motor
SPECIFICATIONS
MODEL L (IN) L (MM)
EN656M5XL 20.50 520.7
EN656M86XL 17.89 454.4
EN656M72XL 17.89 454.4
CP656M72XLR 17.89 454.4
CP656FU72XLR 17.89 454.4 A TERMINAL BOX CONNECTOR HOLE 3/4" NPT FEMALE THREAD
DIMENSIONS: INMM
TOLERANCES: .XX ± .082
(UNLESS OTHERWISE NOTED)
Scale CAD drawing available upon request.
Same as EN656M72XL
080059except addChemical
Processing (CP)
features from catalog
inside front cover
1 Rotron motors are designed to handle a broad range of world voltages and power supply variations. Our dual voltage 3 phase motors arefactory tested and certified to operate on both: 208-230 /415-460 VAC-3 ph-60 Hz and 190-208/380-415 VAC-3 ph-50 Hz. Our dualvoltage 1 phase motors are factory tested and certified to operate on both: 104-115/208-230 VAC-1 ph-60 Hz and 100-110 /200-220VAC-1 ph-50 Hz. All voltages above can handle a ±10% voltage fluctuation. Special wound motors can be ordered for voltages outside ourcertified range.
2 Maximum operating temperature: Motor winding temperature (winding rise plus ambient) should not exceed 140°C for Class F rated motorsor 120°C for Class B rated motors. Blower outlet air temperature should not exceed 140°C (air temperature rise plus inlet temperature).Performance curve maximum pressure and suction points are based on a 40°C inlet and ambient temperature. Consult factory for inlet orambient temperatures above 40°C.
3 Maximum blower amps corresponds to the performance point at which the motor or blower temperature rise with a 40°C inlet and/orambient temperature reaches the maximum operating temperature.
MODEL EN656M5XL EN656M72XL EN656M86XL CP656FU72XLRPart No. 080060 080059 080058 080142Motor Enclosure – Shaft Material Explosion-proof–CS Explosion-proof–CS Explosion-proof–CS ChemXP – SSHorsepower 3 3 3Phase – Frequency 1 Single - 60 Hz Three - 60 Hz Three - 60 HzVoltage 1 208-230 208-230 460 575Motor Nameplate Amps 3 15.5-14.5 7.4 3.7 3.0Max. Blower Amps 3 16.3-16.8 8.2 4.1 4.1Inrush Amps 95-86 54 27 21.6Starter Size 1 0 0 0Service Factor 1.0 1.0 1.0Thermal Protection 2 Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot DutyXP Motor Class – Group I-D, II-F&G I-D, II-F&G I-D, II-F&GShipping Weight 135 lb (64 kg) 110 lb (50 kg) 110 lb (50 kg)
Rev. 2/04
140
AMETEK Technical and Industrial Products, Kent, OH 44240 • e mail: [email protected] • internet: www.ametektmd.com
ROTRON Regenerative Blowers
SectionC 2004.qxd 6/26/04 10:53 AM Page C-14