Front Cover
F-OPE-067 Rev.3
Ensco 5002
Flare Boom (Repair)
Date: Jun 2012
Doc. No: IRM3329
Version: Original P.O nº: 10117-0000007582
CONTENTS
Página 1 de 1
F-OPE-068 Rev.0
Flare Boom (Repair)
1. Executive summary Report
2. Reset Flare Boom
3. Walkways Grating
IRM Services Documentation
4. Personnel Qualification
5. IRM Services Documentation
PREPARED BY: José Raimundo F.M.Jr
POSITION: Supervisor
REVIEWED BY: Felipe Oliveira
POSITION: Reports Analyst
APPROVED BY: Barry Newman
POSITION: Operations Manager
SIGNATURE:
DATE: June, 2012
SIGNATURE:
DATE: June, 2012
SIGNATURE:
DATE: June, 2012
Client :
Location : Ensco 5002
Project No: IRM3329
EXECUTIVE SUMMARY REPORT
Page 1 of 1
F-OPE-018a - Revision. 2
Client: Ensco. Location: Ensco 5002 Project: Flare Boom weld Repair
Technicians on Board: José Raimundo Jr, Paulo Cesar, Sidiomar Rosa Client Representative: Renata Rodrigues Dates of Project: 06/18/12 to 06/27/12 Project Workscope: I.R.M. were requested to carry out a Flare Boom Weld Repair on behalf of Ensco onboard the Ensco 5002 This was carried out during the period of June 2012. I.R.M would like to take this opportunity to thank all crew involved for their assistance throughout this busy operational period. Project Summary: It was carried out Installation of Walkways Grating of STBD side, Port side and R eset Flare Boom Reduction of size 5000mm to 3740mm. All of these were inspected in accordance with ASME V, ASTME 1444/709, ASTME 165, API, ABS, DNV or BV which ever was applicable for the correct tool. Signed on behalf of I.R.M:
José Raimundo – Irata ll 06/27/12
PHOTOGRAPH REPORT
Page 1 of 2
F-OPE-043 Rev.3
Customer : Ensco Location : 5002
P.O. No : 10117-0000007582 W.I. No: 3329 Report No : PR-IRM3329-001
Item : Stbd Reset Flare Boom 6’’
Details: Reset Flare Boom Reduction of Size 5000mm to 3740mm)
Inspector: José Raimundo F.M.Jr
Qual: ER – Irata ll
Signature : Date : 24 June 2012
For Client use :
For Certifying Auth. use :
PHOTOGRAPH REPORT
Page 2 of 2
F-OPE-043 Rev.3
Customer : Ensco Location : 5002
P.O. No : 10117-0000007582 W.I. No: 3329 Report No : PR-IRM3329-002
Item : Port Reset Flare Boom 6’’
Details: Reset Flare Boom Reduction of Size 5000mm to 3740mm)
Inspector: José Raimundo F.M.Jr
Qual: ER – Irata ll
Signature : Date : 24 June 2012
For Client use :
For Certifying Auth. use :
PHOTOGRAPH REPORT
Page 1 of 2
F-OPE-043 Rev.3
Customer : Ensco Location : 5002
P.O. No : 10117-0000007582 W.I. No: 3329 Report No : PR-IRM3329-003
Item : Walkways Grating
Details: (Installation Walkways Grating of Stbd Side)
Inspector: José Raimundo F.M.Jr
Qual: ER – Irata ll
Signature : Date : 24 June 2012
For Client use :
For Certifying Auth. use :
PHOTOGRAPH REPORT
Page 2 of 2
F-OPE-043 Rev.3
Customer : Ensco Location : 5002
P.O. No : 10117-0000007582 W.I. No: 3329 Report No : PR-IRM3329-004
Item : Walkways Grating
Details: (Installation Walkways Grating of Port Side)
Inspector: José Raimundo F.M.Jr
Qual: ER – Irata ll
Signature : Date : 24 June 2012
For Client use :
For Certifying Auth. use :
This certifies that
was independently assessed as
on
Signed on behalf of IRATA
John G Fairley
Secretary
IRATA No:
Expiry Date:
Date Originally Assessed at this level:
Jose Raimundo Jr Meneses
Level 2 Rope Access Technician
05 May 2012
2/3669604 May 2015
05 May 2012