1
Easy service End suction pump in multiple sizes Armstrong says its versatile 4270 end suction motor-mounted cen- trifugal pump is now available in eleven versions. Models are available in single and three phase options as well as 575 volt - altogether there are 31 variations. towers, clean rooms, and general purpose applications. Available in cast iron and bronze construction, the pump can be adapted to horizontal and vertical installations. The Series 4270 is suitable for the The 4270 features a stainless steel HVAC market, and for cooling shaft and face plate, a Viton Piece of filter cake Ready-to-use solution for feeding filter presses The filter press is an apparatus for solid/liquid separation that either reduces the volume of products or filters solutions. Its operating cycle consists of two essential phases that are directly related to the upstream pumping solution: filling, followed by maintenance of pressure at the end of the cycle. The system selected must comply with certain requirements, such as guaranteed filling with a high flow-rate for better control of cycle time, verification of flow- rate during the pressure mainten- ance phase to provide a better filtration quality or maintenance of the minimum desired flow-rate at the end of the cycle for a better filter cake quality. PCM Pompes has developed a ready-to-use solution with its Series 1 Moineau PCM pump. As a result of the use of a flow- pressure-time-power regulation system, Series 1 pumps derived from the Moineau PCM line ensure filter press feeding while guaranteeing optimal operation throughout the different phases of the pressure maintenance cycle. The filter press feed system is suit- able for all models: platen filter press, membrane platen filter press and dual feed filter press. The use of one Series 1 pump is particularly well suited for small filter presses. This pump can be used to carry out the entire cycle, from high flow-rate filling up to the end of the pressure mainten- ance phase with a minimum flow-rate. The use of two Series 1 pumps is designed for large filter presses, where the filling flow-rate is high- er, in order to guarantee reduced cycle time. Combining two pumps enables a broader flow-rate range to be obtained in order to respond to filtering requirements at the beginning of the process (very high flow-rate) and at the end of the cycle (very low flow- rate). Turnkey installation allows for closed circuit operation throughout the cycle, thereby guaranteeing a shorter pressing cycle than with another pump technology. Frequently used for decon- tamination installations, the filter press feed proposed by PCM is perfectly suited to the most varied sectors of activity. During the construction of water treatment stations using a filter press, or when an installation is modemised by the operator, the PCM Moineau pump offers a potential solution for both urban stations and industrial sites such as surface treatment plants, tanneries or paper mills. CONTACT PCM Pompes, 17 Rue Ernest Laval, BP 35, 92173 Vanves, Cedex, France. Tel: +33 141 081515; Fax: +33 141 081500; E-maih [email protected]; www, pcmpompes.com mechanical seal (suitable up to 275°F), and is designed for flows to 100 gpm at pressures to 50 psig (115 tdh). The back pull-out design eliminates the need to break piping connections if servicing becomes necessary. The motor, with the bracket and impeller attached, can be easily withdrawn from the vol- ute after removing the volute capscrews. Equipped with heavy Shear cleanliness duty, permanently lubricated ball bearings, the motor is rated to accommodate all pump radial and hydraulic loads and is designed to operate at 3500 rpm. CONTACT Armstrong Limited, 23 Bertrand Avenue, Toronto, Ontario MIL 2P3, Canada. Tel: +1 416 755 2291; Fax: +1 416 755 8469. Benefits of PD pumps outlined in literature Alfa Laval Flow's latest brochure features its GHPD line of positive displacement pumps and illus- trates how they can pump viscous product through a system while ensuring low product shear. The brochure includes drawings, photos and specification charts explaining the many benefits they may provide. An exploded view of a GHPD pump offers a photo- graphic representation of the pump's components and how they fit together. kind to meet today's demanding hygienic standards by offering clean-in-place (CIP) capabilities. The GHPD pumps are authorized to carry the 3A symbol and are USDA approved for both the dairy and egg industries. The pump's Hyclean ® seal keeps work- ing parts away from the medium to ensure product integrity at all times. The twelve models to choose from include capacities ranging up to 466 gallons/minute. The GHPD delivers a combina- tion of rugged, low-maintenance construction with efficient, gentle pumping through a wide range of viscosities. According to Alfa Laval, it was the first pump of its Seal kit CONTACT Alfa Laval Flow Inc, 8201 104th St, PO Box 581909, Pleasant Prairie, Wisconsin 53158-0909, USA. Tel: +1 262 947 4700; Fax: +1 262 947 4724; www.alfalaval.com O-ring kits will aid plant maintenance Boxed kits of popular sized metric The boxes are designed and imperial O-rings, from James Walker, should help maintenance engineers and equipment refur- bishers to store and carry a selec- tion of rings to suit many indus- trial applications. to withstand industrial maintenance use and have partitions to hold items separately. Also, the layouts of the kits show users when they are running low on a particular size of ring or cord.. Three different kits are available: Imperial kit, con- taining 30 sizes with 382 O-rings in 70 IRHD nitrile. Metric kit, also with 30 sizes, but con- tains 404 O-rings in 70 IRHD nitrile. Service kit. This contains 14 popular sizes of 70 IRHD nitrile O-ring cord, each 2 m long. A knife, tape measure, splicing aid and adhesive are included for forming rings on site. CONTACT James Walker & Co Ltd, Hoe Bridge, Old Woking, Surrey GU22 8JL, UK. Tel: +44 1483 757575; Fax: +44 1483 755711; www.jameswalker.co.uk www.worldpumps.com WORLD PUMPS July 2000 17

End suction pump in multiple sizes

  • View
    214

  • Download
    1

Embed Size (px)

Citation preview

Page 1: End suction pump in multiple sizes

Easy service

End suction pump in multiple sizes Armstrong says its versatile 4270 end suction motor-mounted cen- trifugal pump is now available in eleven versions. Models are available in single and three phase options as well as 575 volt - altogether there are 31 variations.

towers, clean rooms, and general purpose applications.

Available in cast iron and bronze construction, the pump can be adapted to horizontal and vertical installations.

The Series 4270 is suitable for the The 4270 features a stainless steel HVAC market, and for cooling shaft and face plate, a Viton

Piece of filter cake

Ready-to-use solution for feeding filter presses The filter press is an apparatus for solid/liquid separation that either reduces the volume of products or filters solutions. Its operating cycle consists of two essential phases that are directly related to the upstream pumping solution: filling, followed by maintenance of pressure at the end of the cycle. The system selected must comply with certain requirements, such as guaranteed filling with a high flow-rate for better control of cycle time, verification of flow- rate during the pressure mainten- ance phase to provide a better filtration quality or maintenance of the minimum desired flow-rate at the end of the cycle for a better filter cake quality.

PCM Pompes has developed a ready-to-use solution with its Series 1 Moineau PCM pump. As a result of the use of a flow- pressure-time-power regulation system, Series 1 pumps derived from the Moineau PCM line ensure filter press feeding while guaranteeing optimal operation throughout the different phases of the pressure maintenance cycle. The filter press feed system is suit- able for all models: platen filter press, membrane platen filter press and dual feed filter press.

The use of one Series 1 pump is particularly well suited for small filter presses. This pump can be used to carry out the entire cycle, from high flow-rate filling up to the end of the pressure mainten- ance phase with a minimum flow-rate.

The use of two Series 1 pumps is designed for large filter presses, where the filling flow-rate is high- er, in order to guarantee reduced cycle time. Combining two pumps enables a broader flow-rate range to be obtained in order to respond to filtering requirements at the beginning of the process (very high flow-rate) and at the end of the cycle (very low flow- rate). Turnkey installation allows for closed circuit operation throughout the cycle, thereby guaranteeing a shorter pressing cycle than with another pump technology.

Frequently used for decon- tamination installations, the filter press feed proposed by PCM is perfectly suited to the most varied sectors of activity. During the construction of water treatment stations using a filter press, or when an installation is modemised by the operator, the PCM Moineau pump offers a potential solution for both urban stations and industrial sites such as surface treatment plants, tanneries or paper mills.

CONTACT PCM Pompes, 17 Rue Ernest Laval, BP 35, 92173 Vanves, Cedex, France. Tel: +33 141 081515; Fax: +33 141 081500; E-maih [email protected]; www, pcmpompes.com

mechanical seal (suitable up to 275°F), and is designed for flows to 100 gpm at pressures to 50 psig (115 tdh). The back pull-out design eliminates the need to break piping connections if servicing becomes necessary. The motor, with the bracket and impeller attached, can be easily withdrawn from the vol- ute after removing the volute capscrews. Equipped with heavy

Shear cleanliness

duty, permanently lubricated ball bearings, the motor is rated to accommodate all pump radial and hydraulic loads and is designed to operate at 3500 rpm.

CONTACT Armstrong Limited, 23 Bertrand Avenue, Toronto, Ontario MIL 2P3, Canada. Tel: +1 416 755 2291; Fax: +1 416 755 8469.

Benefits of PD pumps outlined in literature Alfa Laval Flow's latest brochure features its GHPD line of positive displacement pumps and illus- trates how they can pump viscous product through a system while ensuring low product shear. The brochure includes drawings, photos and specification charts explaining the many benefits they may provide. An exploded view of a GHPD pump offers a photo- graphic representation of the pump's components and how they fit together.

kind to meet today's demanding hygienic standards by offering clean-in-place (CIP) capabilities.

The GHPD pumps are authorized to carry the 3A symbol and are USDA approved for both the dairy and egg industries. The pump's Hyclean ® seal keeps work- ing parts away from the medium to ensure product integrity at all times. The twelve models to choose from include capacities ranging up to 466 gallons/minute.

The GHPD delivers a combina- tion of rugged, low-maintenance construction with efficient, gentle pumping through a wide range of viscosities. According to Alfa Laval, it was the first pump of its

Seal kit

CONTACT Alfa Laval Flow Inc, 8201 104th St, PO Box 581909, Pleasant Prairie, Wisconsin 53158-0909, USA. Tel: +1 262 947 4700; Fax: +1 262 947 4724; www.alfalaval.com

O-ring kits will aid plant maintenance Boxed kits of popular sized metric The boxes are designed and imperial O-rings, from James Walker, should help maintenance engineers and equipment refur- bishers to store and carry a selec- tion of rings to suit many indus- trial applications.

t o

withstand industrial maintenance use and have partitions to hold items separately. Also, the layouts of the kits show users when they are running low on a particular size of ring or cord..

Three different kits are available:

Imperial kit, con- taining 30 sizes with 382 O-rings in 70 IRHD nitrile. Metric kit, also with 30 sizes, but con- tains 404 O-rings in 70 IRHD nitrile. Service kit. This contains 14 popular sizes of 70 IRHD nitrile O-ring cord, each 2 m long. A knife, tape measure, splicing aid and adhesive are included for forming rings on site.

CONTACT James Walker & Co Ltd, Hoe Bridge, Old Woking, Surrey GU22 8JL, UK. Tel: +44 1483 757575; Fax: +44 1483 755711; www.jameswalker.co.uk

www.worldpumps.com W O R L D P U M P S July 2000 17