20
Digital drainage systems ATMOS ® Thorax COMFORT SAFETY FLEXIBILITY MOBILITY

En brochure atmos thorax 2014 02 09

Embed Size (px)

DESCRIPTION

http://cdn.atmosmed.com/docs/15600/en_brochure_atmos_thorax_2014-02_09.pdf

Citation preview

Page 1: En brochure atmos thorax 2014 02 09

Digital drainage systems

ATMOS® Thorax

COMFORTSAFETY

FLEXIBILITYMOBILITY

Page 2: En brochure atmos thorax 2014 02 09

2

We don’t do anything else. But we do it differently.

ATMOS

The combination makes it special

Development always stands for progress. This applies for thoracic drainage systems which have evolved from simple bottle systems into complex devices. We have been part of this progress since the development of the first digital thoracic drainage unit - ATMOS® S 031 Thorax - in the year 2003. We have made it our aim to reduce the complexity of the device into the simplicity in operation. Thus we are convinced to support you in achieving the best possible therapy results.

Our complete product portfolio ranges from simple surgical suction devices to intelligent systems. Let yourself be convinced by the long standing experience found in each of our products.

Page 3: En brochure atmos thorax 2014 02 09

3

As one of the leading companies for premium surgical suction de-vices and ENT units, our high qua-lity products are in use worldwide.Highly innovative products which have been developed close to our customers demands distinguish ATMOS MedizinTechnik for more than 120 years.

Digital thoracic drainage systemsmade by ATMOS

“ The option of having the water chamber with the ATMOS S 201 Thorax system allows the experienced nurse and surgeon to blend the two systems (analog and digital) together, and help them understand the concept of quantifying the size of an air leak digitally and visually with the bubbles.” “The 12 day graphing system displays the patient’s therapy minute by minute due to the device’s real time flow. Because of the real time flow and the sensitivity of this system, I was able to see the patient’s tidaling (max. flow/min. flow) on the graph by watching the increase and decrease of the flow line during inspiration and expiration.“

Dr. Robert J. Cerfolio Chief Thoracic Surgery UAB

Page 4: En brochure atmos thorax 2014 02 09

4

Problems

When the drainage hose is sagging, secretion accumulates at the lowest point, and cannot be suc-tioned by a conventional thoracic drainage system. The hereby arising secretion column decrea-ses the vacuum at the patient. With every cm secretion column the vacuum is lowered by 1 mbar!

Result: Even at -20 mbar in the secretion canister, it could be possible that there is no vacuum at the patient. There-fore the therapy won´t show the desired result.

Are these problems familiar?

The risky siphon effect

Secretion hoseblocked because of coagulation

Especially after cardiac surgery there is a high risk of coagulum development in the drainage hose. These block the hose and prevent further therapy.Con-ventional drainage systems do not have the ability to rinse out the blood clots.

Result: The hose needs to be milked by hand. This means more work for the nurses and unnecessary pain for the patient.

Secretion hose has a kink

The drainage hose can kink unknowingly for different reasons during the therapy.

Result: The vacuum from the secretion canister cannot be forwarded to the patient. The vacuum in the pleural cavity is undefined and there is no drainage of air and secretion.

Emergency cases and complications are not recognized or it is too late

During a thoracic drainage various complications can develop. When working with conventional drainage systems you must rely on the staffs attentiveness for the early identification of possible problems.The systems have no integrated alarm system.

Page 5: En brochure atmos thorax 2014 02 09

5

We know the solution!

The ATMOS solution

The elaborate ATMOS measuring & hose rinsing system ATMOS drainage systems work with a double lumen hose system. The larger lumen transports air and secretion from the drainage to the secretion canister, as conventional systems do. The smaller lumen is the rinsing and measuring hose.

Measuring function The hose is connected to the sensor of the drainage unit. Siphons, coagulum or other blockages in the drainage hose have no influence on the measurement result. The pump aggregate can regulate the suction accurately in order to reach the target value in the pleura cavity.

Rinsing functionAfter a defined period (standard setting 2 min) a valve opens for a milli second and vents the measuring and rinsing hose. Secretion and coagulum which have been deposited in the secretion hose will be flushed into the secretion canister.

Reliable alarm systems provide early information regarding complicationsDigital thoracic drainage systems by ATMOS offer an elaborate alarm management. The units show a visual and acoustic alarm, if… the target vacuum in the drainage can not be achieved the battery is too lowThe indication doesn´t only show that a problem exists, it also gives possible solutions.With the ATMOS® S 201 Thorax there is also the option to connect the alarm signal to the nurse call system.

Page 6: En brochure atmos thorax 2014 02 09

6

Problems

With the use of conventional systems the only way to get information regarding the therapy progress is to interpret the bubbles, observe the secretion hose and order expensive x-rays.

Result: Due to this process high costs arise and the right point of time to remove the drain can only be determined imprecisely.

Are these problems familiar?

Insufficient information of the actual therapy process

Complex manuel documentation of the healing process

Conventionel systems do not offer automatic documentation of the healing process.

Result: The documentation must be done manually by the nurses. This results in considerable staffing efforts.

Restricted mobility due to connection to thecentral vacuum

Conventional Bülau drainages must be connected to the central vacuum or an electrical suction device in order to create a suction.

Result: The patient is spatially bound so the therapy must be interrupted during a transfer. A mobilisation under active suction is only possible to a limited extent.

Disturbance due to in-tense bubble generation in the control canister Conventionaly two or three canister systems are

connected to intense bubbling in the control canisters.

Result: This leads to a permanent noise exposure for patients and nurses.

Page 7: En brochure atmos thorax 2014 02 09

7

Battery operated, adjustable suction system creates mobility and safety

ATMOS thoracic drainage systems are fully integratable systems. The systems contain fine adjustable, powerful suction aggregates. Due to the automatic control the aggregate always provides the exact flow which is required to maintain the target vacuum. Herewith results… minimal noise exposure and a gentle drainageDue to perfected lithium-ionic batteries the units can opera-te up to 12 h without connection to the main power supply. Therefore relocation and mobilization of the patient is no longer a problem.The recharging time for a fully discharged battery is max. 4 h.

Digital storage of measured values

ATMOS drainage systems have a complex sensor technology and an elaborate data analysis. In the display the target vacuum and the current flow value are displayed digitally.With the ATMOS® S / E 201 Thorax the current vacuum value is also displayed.The ATMOS® C 051 & S 201 Thorax also offer a scalable flow progress display and the possibility to export the data to the computer for backup and processing.

We know the solution!

The ATMOS solution

Page 8: En brochure atmos thorax 2014 02 09

8

The all-round carefree package

With the thoracic drainage systems from ATMOS you will always have the perfect companion for clinical everyday life at your disposal. These systems offer you the possibility for a complete documentation of the vacuum and flow trends from the OT to the removal of the drain. Therefore the focus is enhanced on patients´safety and the greatly improved therapy results.The reliable alarm system reduces the care efforts which benefits both patients and nursing staff .Due to the ATMOS measuring hose system the vacuum values are measured directly at the patient. The siphon effect is excluded because the set values are constantly monitored and changes are automatically balanced.

ATMOS® C 051 Thorax - The compact and mobile solutionIn emergency medical care and pul-monary intensive care mobilization takes on a special role. For this re-ason our ATMOS® C 051 Thorax is an extremely compact, light and an ergonomical solution for pulmona-ry surgery.

One system…The new generation of ATMOS® thoracic drainage systems comes with a standardized operating concept. Thus doctors and nursing staff do not have to focus on the operation of two different devices. The intuitive and almost foolproof operation supports this significantly.

One hose…All digital thoracic drainage systems developed by ATMOS use the same hose system.If your clinic uses various ATMOS drainage systems this offers a wide range of advantages: Easy compound management Only one hose for all devices and all thoracic drainage applications One operating concept The connection of the ATMOS drainage systems is also standardized Different ATMOS drainage systems can be used in combination

Page 9: En brochure atmos thorax 2014 02 09

9

ATMOS® S / E 201 Thorax – Drainage units for every needThere are a lot of reasons why a thoracic drainage is indispensable.If you are looking for a drainage unit which will give you excellent results from the ambulance to emergency medicine, to cardiac surgery intensive care medicine then the ATMOS® S & E 201 Thorax are the perfect solution for you.

Page 10: En brochure atmos thorax 2014 02 09

10

The all-rounder…

Mobile & flexible Up to 12 hours of battery operation. Can be plugged in with any JEC connector. The 360° adjustable universal bracket allows for the connection to e.g. wheelchairs, beds and infusion holders. Carrying straps for the basic device and secretion canisters are also available

Powerful The speed controlled 18 l/min suction meets all application demands. Whether it is for large amounts of coagulation, high secretion flow or the application of several drains - nothing is a problem for the ATMOS® S / E 201 Thorax. The fully transparent secretion canister offers plenty of space and safety even at perforations and strong pleural effusions.

Therapy process control On the main display of the device the target vacuum, the current flow rate and the vacuum are displayed as a numerical value. The water lock which is integrated into the secretion canister offers the possibility to interpret the flow rate via the classic bubble method. The ATMOS® S 201 Thorax additionally offers the possibility to display the therapy progress as a graph over the last 12 days. This data can also be exported via a micro SD card for further processing.

Gravity drainage The target vacuum can be reduced to -5 mbar. Thus the drainage can be performed at physiological vacuum. All advantages of the digital drainage remain.

Page 11: En brochure atmos thorax 2014 02 09

11

Page 12: En brochure atmos thorax 2014 02 09

12

TouchscreenThe ATMOS® C 051 Thorax uses a touchscreen as an input interface. As a result it was possible to create even simpler icons and to arrange the buttons in an easier and more user-friendly way.

Mobile & flexibleUp to 12 hours of battery operation.With only 1.3 kg dead weight, an ergonomic design and a comfortable carrying strap this system is perfect for the fast mobilization of the patient.The optional 360° adjustable universal bracket allows for the connection to wheelchairs, beds and infusion hold-ers

Clear view of the secretionThe 800 ml secretion canister of the ATMOS® C 051 Thorax is divided into a 180 ml and a 620 ml compartment. This leads to ideal balancing require-ments.

Gravity drainageThe active suction can be set to -5 mbar. Thus the unit only preserves the biological normal vacuum and emits air and secretion.Advantages: Physiological effect like a gravity drainage The postition of the unit in the room has no effect on the drainage Alarm functions remain active Hose rinsing remains active Digital information regarding fistulization remains active

The small marvel…ATMOS® C 051 Thorax

Page 13: En brochure atmos thorax 2014 02 09

13

Automatic night modeThe display of the ATMOS® C 051 Thorax includes a night mode for reduced brightness.A light sensor automatically mea-sures the light in the room and then switches to the night mode.

Therapy progress controlOn the main display of the device the target vacuum and the current flow rates are displayed as a numerical value. The possibility to display the ther-apy progress as a graph over the last 12 days is additionally given. This data can also be exported via a USB cable for further processing.

The small marvel…ATMOS® C 051 Thorax

Page 14: En brochure atmos thorax 2014 02 09

14

Sealing caps For an easy handling the caps canbe found directly on the device.The use of sealing caps prevents the leakage of liquids during disposal ofthe canisters.

Canister change with one handProtected by a hydrophobic bacterial filter and integrated overflow stop.

2 chambers for better readabilityThe canister is divided into two chambers, the first has a capacity of 180 ml and the second one 620 ml.

Application with the ATMOS hose systemThe hose system is connected to the canister via a Luer-Lock.Only one hose for all the ATMOS® thoracic drainage units.

Easily recognizable scalingThe scales are marked on the left and right hand side of the canister. Large numbers and a high contrast ensures optimal readability.The white background and the hard surface allow for easy marking.

Secretion canisters with a difference…

Page 15: En brochure atmos thorax 2014 02 09

15

Connection for secretion hose

Sealing caps

Pop-Off valve

Water lock

Hydrophobic bacterial filter with integrated overflow protection

Flow-visualisation through bubbles

4 chambers for easy secretion balancing

Page 16: En brochure atmos thorax 2014 02 09

16

Specifications overview of digital thoracic drainage systems

ATMOS® E 201 Thorax

ATMOS® S 201 Thorax

ATMOS® C 051 Thorax

Max. suction performance 18 l/min 18 l/min 5 l/min

ATMOS single use canister system

Battery operation up to 12 h 12 h 12 h

Real time flow measurement

Flow history

Data export SD-Card USB

Monitoring function

Connection to SRS

Graphic display

Colour display

Gravity drainagedigital gravity mode

at -5 mbardigital gravity mode

at -5 mbardigital gravity mode

at -5 mbar

Vacuum measurement on thepatient

Rinsing function

Vacuum adjustment range(freely adjustable) -5 to - 100 mbar -5 to - 100 mbar -5 to - 100 mbar

Touchscreen

Page 17: En brochure atmos thorax 2014 02 09

17

Secretion canisters ATMOS®

S / E 201 ThoraxATMOS®

C 051 Thorax

Canister capacity 2000 ml 800 ml

Capacity of the first chamber 375 ml 180 ml

Fully transparent

Sealing capfor easy disposal

Hydrophobic bacterial filter with integrated overflow stop

Pop-off valvefor safety when coughing and by artificial respiration

Water lock

Luer-Lock connection

Ergonomical design

Direct Docking System

Page 18: En brochure atmos thorax 2014 02 09

18

REF 312.1160.0 REF 312.1005.0 REF 312.2021.01 2 3

54 6REF 312.1031.0 REF 312.1170.0 REF 312.1150.0

ATMOS® S / E 201 ThoraxAccessories & Consumables

ATMOS® S / E 201 Thorax REFATMOS® E 201 ThoraxMobile thoracic drainage system of the ATMOS “E-class“Suitable for transport within the hospital and to accompany the patient from theoperating room to the end of therapy. Fully electronic monitoring, real-time flowmeasurement, alarm function, ergonomic monochrome display.

312.1100.0

ATMOS® S 201 Thorax Mobile thoracic drainage system of the ATMOS “S-class“Suitable for transport within the hospital and to accompany the patient from theoperating room to the end of therapy. Fully electronic monitoring, real-time flowmeasurement, flow history, data export via SD card, alarm function (can be connected to nurse call system), ergonomic colour display.

312.1000.0

Accessories ATMOS® S / E 201 ThoraxUniversal bracket 312.1160.0

Carrying bag for canister 312.1005.0

Micro SD card 312.2021.0

Consumables ATMOS® S / E 201 ThoraxOP-Set for ATMOS® E/S 201 Thorax 312.1031.0

Tubing system 312.1170.0

Secretion canister, 2 l 312.1150.0

1

2

3

4

5

6

Page 19: En brochure atmos thorax 2014 02 09

19

REF 316.0200.0 REF 316.1100.0 REF 317.0008.01 2 3

54 6REF 313.0080.0 REF 312.1170.0 REF 317.1000.0

ATMOS® C 051 Thorax REFMobile Thoracic Drainage System of the “C-class”Suitable for transport within the hospital and to accompany the patient from the operating room to the end of therapy.Fully-electronic monitoring, real-time flow measurement, flow history, data export, alarm function and ergonomic colour display.Technical Data:Air-flow rate of pump: 5 l/min, noise level: max 39 dB (A) 1m (acc. to ISO 7779),Dimensions (H x W x D): 164 x 206 x 95 mmIncluded in delivery:Basic device, carrying strap, charging device, operating instructions, short instruction

317.0000.0

Accessories ATMOS® C 051 Thorax REFDevice bracket 316.0200.0

Carrying strap 316.1100.0

Strap holder 317.0008.0

Charging device 313.0080.0

Consumables ATMOS® C 051 Thorax REFTubing system 312.1170.0

Disposable secretion canister 800 ml 317.1000.0

1

2

3

4

5

6

ATMOS® C 051 ThoraxAccessories & Consumables

Page 20: En brochure atmos thorax 2014 02 09

For further information: www.atmosmed.com

Contact:ATMOS MedizinTechnik GmbH & Co. KGLudwig-Kegel-Str. 1679853 Lenzkirch / [email protected] P0

94.1

833.

2 • 2

014-

02 I

ndex

: 09