292
emeRGency liGhTinG

Emergency Lighting A1

  • Upload
    others

  • View
    10

  • Download
    2

Embed Size (px)

Citation preview

Page 1: Emergency Lighting A1

RZB Rudolf Zimmermann, Bamberg GmbH

Rheinstrasse 16 D-96052 Bamberg Germany

Telephone +49 951/79 09-374Fax +49 951/79 09-212

www.rzb.eu [email protected]

KAT3

9EN

emeRGency liGhTinG

emer

gen

cy l

igh

tin

g

A1

Page 2: Emergency Lighting A1

www.rzb-lighting.com

RZB Rudolf Zimmermann, Bamberg GmbH

Rheinstrasse 16, D-96052 Bamberg, Germany P.O. Box 29 40, D-96020 Bamberg, Germany

Telephone +49 951/79 09-374 Fax +49 951/79 09-212

[email protected]

www.rzb-lighting.com

CUSTOMERCONTACT

289

Page 3: Emergency Lighting A1

1

Contents

Self-contained emergency lighting

Self-contained monitoring systems 8 - 23

Self-contained emergency luminaires 24 - 111

Self-contained emergency conversion kits 112 - 121

Central and group battery systems

Central battery systems (CPS) 122 - 140

Group battery systems (LPS) 141 - 157

Luminaires for central emergency power supply 158 - 239

Standards and regulations 240 - 267

Planning 268 - 269

Appendix 270 - 288

Service 272 - 273

EVG symbol 274

LED symbol 275

Catalogue number codes 276

Motifs and lettering for emergency luminaires 277

Motifs and lettering for luminaire signs 278 - 279

Lamps 280

Terms and conditions of sale and delivery 281

Catalogue number index 282 - 286

Alphabetical index 287 - 288

Technical support 289

After sales service 289

Contact for emergency lighting 289

Page 4: Emergency Lighting A1

2

New products

Self-contained moni-toring systems

Self-contained emer-gency luminaires

Self-contained emer-gency conversion kits

SINGLE BATTERY

10 18 2214

118116 - 117114 116 - 117

28, 30 - 31 28, 30 - 31 32

44, 47 50 52

38

40 - 4340 - 43

74

54, 56 - 57 54, 58 - 59 54, 58 - 59

76 - 79

94 96

64 6866

44, 45

26 28 - 29

44, 46

60

54, 55

70 72

62

88

10290 10492 10098

80 - 83 84 86

3634

106 110110108

LED LED LED

LED LED

LEDLEDLED

LED LED

LED

LED

LED LED

LED

LED LED LED

8h 8h

8h8h8h

8h

8h

Page 5: Emergency Lighting A1

33

New products

Luminaires for central emergency

power supply

Central battery systems (CPS)

Group battery systems (LPS)

CENTRAL BATTERY

132

144

138128

142

162, 164 162, 165 166

182 - 185 186 188, 189

172 - 174

176, 177172 - 174

216

188, 192 194 196

218

202

206

204

176, 178

168160 162 - 163

176, 179

170

198

188, 190

188, 192

208 - 210 212 - 214

200

228 236 238230 234230

222

232

220 224

226

LED LED LED LED LED

LED LED

LED LED

LED

LED LED LED

LED

LED

LED LED LED

Page 6: Emergency Lighting A1

4

A view of our plant and its solar panels.Solar panel surface: 30,000 square meters Number of modules: 5,000Output: more than 1.1 megawatts Greenhouse gas savings: 930,000 kilograms per year

About us

We have been making luminaires of exceptional

quality for more than seven decades. At RZB,

our daily activities center around the nowadays

often mentioned subjects of innovation, quality,

design, energy efficiency, environmental friend-

liness and customer service.

Our luminaires are manufactured using the most

advanced production technologies available

today. These products combine outstanding

innovation with the latest lighting technologies;

and the fact that we operate our own R&D

lab guarantees that all of our products comply

strictly with all applicable legal regulations.

The designs of our luminaires combine optimal

technical characteristics and exemplary func-

tionality, thus enabling us to offer our custom-

ers the best possible luminaires and lighting

solutions. The use of select materials and our

ISO 9001:2000 quality assurance system are

your guarantee of the outstanding quality and

exceptionally long service life of our luminaires.

This applies in particular to the plastics, die-

cast components, luminaire glasses, and sur-

face coatings used in our products.

Many items in our portfolio are on hand at all

times, thanks to our highly efficient logistics

workflows and the fact that we keep a great

number of components and finished products

always in stock.

We also provide presales advice, lighting system

planning services, demos and workshops.

Page 7: Emergency Lighting A1

5

Improved light source energy efficiency, lamps

miniaturization, and the dizzying pace of

advances in LED technology are the challenges

currently facing the luminaire industry today,

particularly in view of the fact that lighting

accounts for 20 percent of worldwide energy

consumption.

The manufacture of incandescent light bulbs has

been phased out by law in the EU, thus making

it more urgent than ever for the European light-

ing industry to develop luminaires that use new

types of more energy efficient lamps.

Energy efficiency without dimming the lights

Another environmental aspect that plays a key

role in designing and developing our luminaires

is the use of extremely high quality materials,

which are selected with durability, environmen-

tally friendly manufacturing, and recyclability

firmly in mind. This is our way of making a last-

ing contribution to environmental stewardship.

Environmental stewardship

Page 8: Emergency Lighting A1

6

Quality

Our quality assurance system is DIN EN ISO

9001: 2000 compliant.

Photometry lab Heat measurement lab EMC lab Protection type testing

Memberships in industry organizations

Page 9: Emergency Lighting A1

7

RZB emergency lighting: the smart choice

All your luminaire needs from a single vendor

We offer a complete range of emergency and

general lighting products. This means that we

can offer you integrated solutions for both

types of applications – which in turn saves you

the trouble of dealing with other vendors.

Reliability

Our luminaires integrate extremely reliable elec-

tronics and are highly durable thanks to the

use of exceptionally high quality electronic

components and high tech LED lamps – not to

mention our extensive testing program, whose

scope far exceeds the statutory minimum.

Lighting technology

The luminaires that we develop in our state of

the art lab meet all applicable industry stand-

ards. In emergency situations, our emergency

luminaires enable building occupants to exit

the building safely. And what’s more, the use

of high tech LEDs allows for greatly reduced

energy consumption.

Superior quality luminaires and luminaire designs

We use the most advanced manufacturing technologies available and adhere to an extremely high develop-

ment standard. We have more than three decades of experience in the use of high tech materials and the

development of systems that allow for continuous improvement in the efficiency of emergency lighting.

Installation

When developing our luminaires, we always keep

in mind the aspect of installation-friendliness,

thus guaranteeing rapid and simple handling

in building construction settings, thanks to the

use of elements such as plug-in connectors

and modular technologies.

Customer service

We offer comprehensive planning services for

customer specific emergency lighting systems,

and also provide support for the commission-

ing phase. Plus you can count on outstanding

after-sales service from our team of experi-

enced technicians and engineers.

Sustainability

Environmental sustainability is a top priority

for us in terms of not only the manufacturing

process, but also – and especially – the finished

product. All of our luminaires contain 100 percent

recyclable materials that are notable for their

exceptional durability and quality.

Page 10: Emergency Lighting A1

8

Monitoring system DALI MultiDigit® MWEBplus PZ 50

System structure modular modular single module single module

Colour display • – – –

Number of circuits, basic unit 2 1 1 1

Number of luminaires per circuit 64 125 125 50

Number of luminaires per basic unit max. 128 max. 125 max. 125 max. 50

Expandable•

max. 64 modules

max. 125 modules– –

Max. number of luminaires 4,096 15,625 125 50

Error visualisation Display LED LED LED

Potential-free contacts for error messages

accessories (optional) • • •

E-mail communication•

(optional)

(optional)• –

Network connection•

(optional)– – –

Modualr structure • • – –

Bus line topography free free free ring

Bus lineIY-ST(Y) 2 x 2 x 0.8

or NYMIY-ST(Y) 4 x 2 x 0.8 IY-ST(Y) 2 x 2 x 0.8 IY-ST(Y) 2 x 2 x 0.8

Installation environment small to large buildings

large to very large buildings

small to medium sized buildings small buildings

Type of installation Recessed wall installation, Surface wall installation top hat rail top hat rail top hat rail

Accessories Controller without displaySignal amplifier

MWEB– –

Page 11: Emergency Lighting A1

9

Self-contained monitoring systems

DALI monitoring system 10 - 13

MultiDigit® monitoring system 14 - 17

MWEBplus monitoring system 18 - 21

PZ 50 monitoring system 22 - 23

Page 12: Emergency Lighting A1

10

EMERgENCY LIghTINg | SELf-CoNTAINED MoNIToRINg SYSTEMS

DALI interface

System benefits

- DALI monitoring units with touchscreen and logical menu guidance

- 2 circuits, with 64 luminaires each

- All luminaires with self-test function

- Lighting in complex building structures can easily be realized via network connection

- Visualisation of connected system(s) via TCP/IP (optional)

- Automatic generation of detailed log book

- Execution of all mandatory controls at minimum costs

- Programmable also via USB

- Formation of groups

- Preinstalled operating software

- System setup with software via USB

- Bidirectional communication between luminaire and touchscreen with status and error messages

- Easy to install, setup and maintain

- Bus structure: star-shaped, linear and tree-shaped

- Control line: DC-isolated and reverse voltage protected

- No specific bus line required

- Password protection

- Emergency lighting function disabled outside of normal operating hours

- No need to respect bus line polarity

Monitoring systems with

Please note:

All modules and luminaires for DALI must have order suffix (Y) .07

Easy to operate via touchscreen

Page 13: Emergency Lighting A1

11

LN

L

EMERgENCY LIghTINg | SELf-CoNTAINED MoNIToRINg SYSTEMS

Tender texts available upon request | Specifications subject to alteration

DALI interfaceSystem description

This system is based on the DALI Standard (IEC 62034 and IEC 62386) and allows for central monitoring of up to 128 self-contained emergency luminaires.

It is operated and monitored via touchscreen (DALI control unit) with logical menu guidance for easy use.

The DALI control unit is housed in a high-quality metal casing for either surface wall installation or recessed wall installation.

By interconnecting more control units, the monitoring of emergency lighting systems can be easily realized even in complex building structures.

for this purpose the single DALI control units can be interconnected via an existing local network (TCP/IP), and the entire system can be operated and monitored from one central PC.

As an option it is also possible to control the system via internet.

The DALI control unit communicates continuously with the connected self-contained emergency luminaires and is thus able to immediately display any error.

The logical menu guidance provides the operator within a few steps detailed information concerning type and location of the respective error as well as further indications for error elimination, if applicable.

Automatic self-test function of the luminaires as well as generation of a detailed test log contribute notably to a reduction of time and costs for mandatory emergency lighting systems tests.

Luminaires / Modules: order suffix .07

Power supply: 230 V / 50-60 hz

Power supply (bus line): max. 250 mA, 22.5 V

Max. bus length: 300 m (between control unit and last luminaire)

Transfer rate: 1,200 Bit/s at a voltage level of 16 V

Monitoring system DALI985405 Surface L 148,5, B 92, h 60985406 Recessed L 148,5, B 92, h 8, hE 52, LA 135, BA 80

Surface wall installation Recessed wall installation

BUS port

Mains port

Ethernet

Rear view of DALI unit

DALI circuit 2

CAT. 5 Ethernet (network optional)

LPENDisable function (optional)

DALI circuit 1

BA

LA

LHE H

B

L

B

H

Page 14: Emergency Lighting A1

12

EMERgENCY LIghTINg | SELf-CoNTAINED MoNIToRINg SYSTEMS

Tender texts available upon request | Specifications subject to alteration

Monitoring via DALI interface

general mains power supply

L

N

general mains power supply

L

N

general mains power supply

L

N

DALI Controller

max. 64 luminairesmax. 300 m

DALI BUS circuit 1

DALI BUS circuit 2

Page 15: Emergency Lighting A1

13

654321

NL`

LPE

654321

NL`

LPE

654321

NL`

LPE

654321

NL`

LPE

654321

NL`

LPE

654321

NL`

LPE

654321

NL`

LPE

654321

NL`

LPE

654321

NL`

LPE

654321

NL`

LPE

EMERgENCY LIghTINg | SELf-CoNTAINED MoNIToRINg SYSTEMS

Tender texts available upon request | Specifications subject to alteration

Monitoring via DALI interface

Ethernet Switch

Mains 230 V

DALI BUS2 x 1.5 mm2

DALI module 1

DALI module 2

DALI module 3

DALI module 4

DALI module 64 DALI module 64

(depending on version)

(depending on version)

(depending on version)

(depending on version)

(depending on version)

DALI BUS-curcuit 1 Max. 64 luminaires Max. length: 300 m

DALI BUS-curcuit 2 Max. 64 luminaires Max. length: 300 m

DALI BUS 2 x 1.5 mm2

DALI module 1

DALI module 2

DALI module 3

DALI module 4

(depending on version)

(depending on version)

(depending on version)

(depending on version)

(depending on version)

Page 16: Emergency Lighting A1

14

EMERgENCY LIghTINg | SELf-CoNTAINED MoNIToRINg SYSTEMS

MultiDigit®

System benefits

Continuous central local monitoring of all emergency luminaires using a normal PC, or intranet/internet-based monitoring using MWEB module (PC for system control can thus be eliminated).

- Automatic system configuration

- Plain-text reports of all malfunctions, with indication of failure location

- Coordination of self-test activation of all self-contained emergency luminaires

- Error message logs (PC and/or printer)

- Detailed information and control options for each single emergency luminaire

- Input port for evacuation function (fire brigade)

- Each signal amplifier is fitted with a tap for forwarding collective/group errors to superior systems

- Max. 15, 625 luminaires

Monitoring systems for large buildings

general circuit diagram for the MultiDigit® monitoring system

* The minimum cross-section of the bus line depends on the actual length of the bus line and the number of connected luminaires. Please consult the WINLink manual for detailed information on cable cross-sections.

No. 1

No. 1

No. 2

No. 2

No. 3

No. 3

No. 4

No. 4

Signal converter

max. 30 m

Signal amplifier

no. 1

Signal amplifiermax. 125

max. 125

max. 125

max. 1,000 m at 0.8 mm2

max

. 1,0

00 m

at 0

.8 m

m2

Emergency luminaires with order suffix .04

Type

of b

us li

ne: e

.g. J

-Y(S

t)Y 2

x2x0

.8

Type of bus line: e.g. J-Y(St)Y 2 x 2 x 0.8up to 125 luminaires

- Interference-free communication provided by signal amplifier; communication line length: max. 2 x 1,000 m

- Simple installation of communication line: T-shaped, star-shaped, linear or even mixed structure. No need to respect polarity.

- Emergency lighting function disabled outside of normal operating hours

- Remote control of MultiDigit® systems via modem or MWEB

- Ongoing records of all system malfunctions

- Automatic generation of detailed system test log

- Execution of all mandatory emergency lighting system controls at minimum costs

- Password protection for system data changes

No. of lumi-naires

per line

Max. line length

Min. cross-section

of bus line

Cable type, e.g.:

40 1,000 m 0.5 mm2 J-Y(St) Y 2 x 2 x 0.8 mm (one core)

80 1,000 m 1.0 mm2 J-Y(St) Y 2 x 2 x 0.8 mm (two cores)

125 1,000 m 1.5 mm2 J-Y(St) Y 4 x 2 x 0.8 mm (three cores)

Page 17: Emergency Lighting A1

15

EMERgENCY LIghTINg | SELf-CoNTAINED MoNIToRINg SYSTEMS

Tender texts available upon request | Specifications subject to alteration

System description

The MultiDigit® system allows for continuous central control of self-contained emergency luminaires, which report their momentary states to a PC, which evaluates and controls the entire system. An immediate and clear overview of the entire system can thus be provided and used for determining the operational readiness of the emergency lighting system.

Ease of use is ensured by the user-friendly software WINLink, which runs under any current Windows operating system.

The system is very easy to set up. 125 signal amplifiers (grouped and with 125 self-contained emergency luminaires each) can be installed according to the general circuit diagram indicated on page 14. The signal amplifiers ensure interference-free communication over transmission lengths of up to 2,000 meters throughout the entire system.

The communication line does not need to comply with any particular requirements; its structure can be T-shaped, star-shaped, linear or even mixed. Bus line polarity needs not to be considered. one fully-installed system can monitor 15,625 luminaires.

Planning and installation

The address of the emergency luminairs’ signal amplifiers is stored in a microcontroller and therefore needs to be indicated when ordering the system. It can be reprogrammed during the system setup.

System setup and training of the operating personnel by an RZB technician is available upon request and charge.

for information concerning technical issues and planning assistance, please contact your sales representative.

MultiDigit®

H

B

L

Page 18: Emergency Lighting A1

16

EMERgENCY LIghTINg | SELf-CoNTAINED MoNIToRINg SYSTEMS

Tender texts available upon request | Specifications subject to alteration

MultiDigit®

Starter setType of protection: IP 20 Protection Class: I

for connecting a maximum of 125 RZB luminaires with feedback function (.04), consisting of signal amplifier, signal converter, software and 5 m connecting cable to serial interface of PC (SUB-D9).

Type of installation: DIN profile track

Starter set 671315.000 L 155, B 75, h 120

Signal amplifierfor connecting a further 125 RZB luminaires with incorporated feedback (.04)

Signal amplifier 671148.000 L 155, B 75, h 120

MWEB monitoring modulefor connection to signal amplifier via enclosed interface cable.

The MWEB monitoring module forms the interface between the bus system of the MultiDigit® system and an on-site Ethernet network. MWEB performs the entire control and error management of the emergency lighting system. The system does not require its own PC.

The MWEB module can be accessed via web navigator from any PC in the network that is connected to intranet/internet, without the need for any special software.

for this purpose, the data stored in MWEB are transmitted to the navigator via TCP/IP protocol.

Any malfunction within the system will be immediately displayed in the navigator window; the incorporated e-mail function allows detailed information on the malfunction to be sent to the system administrator. The system can also be accessed via internet if the network is configured accordingly.

MWEB monitoring module 671611.000 L 158, B 90, h 58

H

B

L

H

B

L

Page 19: Emergency Lighting A1

17

Webbrowser

(1) (1) (1)

(4) (4) (4)

(5) (6)(7)

(2)

Sig na lverstä rkerM-B US 28V DCL N

Art.Nr.: 671149.000

blink. = Kom munikation

Art.Nr.: 671148.000

8 7 6 5 4 3 2 1

M-BUS28V DC

Spez. Allg.

NotlichtbausteineM-BUS 28 V DC

Hauptleitung

L N

SN 104

Art.Nr.: 671148.000

8 7 6 5 4 3 2 1

M-BUS28V DC

Spez. Allg.

NotlichtbausteineM-BUS 28 V DC

Hauptleitung

L N

SN 27

Art.Nr.: 671148.000

8 7 6 5 4 3 2 1

M-BUS28V DC

Spez. Allg.

NotlichtbausteineM-BUS 28 V DC

Hauptleitung

L N

SN 07

Sig na lverstä rkerM-B US 28V DCL N

Überwachungsmodul für MultiDigit Notbeleuchtungssysteme

MWEBArt.Nr.: 671611.000

RS232nur für Wartung

SystemLAN

Ethernetzu

Signalwandler

IP . . .

654321

NLPE

654321

NLPE

654321

NLPE

654321

NLPE

654321

NLPE

654321

NLPE

654321

NLPE

654321

NLPE

654321

NLPE

654321

NLPE

654321

NLPE

EMERgENCY LIghTINg | SELf-CoNTAINED MoNIToRINg SYSTEMS

Tender texts available upon request | Specifications subject to alteration

Monitoring via MWEBPlease note:

All modules and luminaires for MultiDigit® must have order suffix (Y) .04

Max

. 125

lum

inai

res

/ M

ax. l

ine

leng

th: 1

,000

m

Max. 125 signal amplifier / Max. line length: 1,000 m

MultiDigit® module 1

MultiDigit® signal amplifier-M2

MultiDigit® signal amplifier-M2

MultiDigit® signal amplifier-M2

MultiDigit® signal amplifier-M2

MultiDigit® module 1MultiDigit® module 1

MultiDigit® module 2MultiDigit® module 2MultiDigit® module 2

MultiDigit® module 3MultiDigit® module 3

MultiDigit® module 4 MultiDigit® module 125

MultiDigit® module 125

(1) Communication line(2) Main line(3) Multidigit emergency luminaires

RS 232 direct line max. 10 m

RS 232 / max. 10 mMeter BUS 28 V DC

Meter BUS 28 V DC Meter BUS 28 V DC Meter BUS 28 V DC

Ethernet Switch

(4) Signal amplifier (K box)(5) Signal converter (K vert)(6) MWEB (optional)(7) PC with web browser

Page 20: Emergency Lighting A1

18

EMERgENCY LIghTINg | SELf-CoNTAINED MoNIToRINg SYSTEMS

MWEBplus

System benefits

Continuous central local monitoring of all emergency luminaires (PC for system control is not required).

- Automatic system configuration

- Plain-text reports of all malfunctions, with indication of failure location

- Coordination of self-test activation of all self- contained emergency luminaires

- Error message logs (PC and/or printer)

- Detailed information and control options for each single emergency luminaire

- Tap for forwarding collective/group errors

- Max. 125 luminaires

- Failures will be communicated automatically via e-mail to individually assignable addresses

Monitoring systems

- Interference-free communication provided by signal amplifier; communication line length: max. 1,000 m

- Simple installation of communication line: T-shaped, star-shaped, linear or even mixed structure. No need to respect polarity.

- Emergency lighting function disabled outside of normal operating hours

- Ongoing records of all system malfunctions

- Automatic generation of detailed system test log

- Execution of all mandatory emergency lighting system controls at minimum costs

- Password protection for system data changes

- No need to respect bus line polarity

general circuit diagram for the MWEBplus monitoring system

* The minimum cross-section of the bus line depends on the actual length of the bus line and the number of connected luminaires.

No. 1 No. 2 No. 3 No. 4MWEBplus

max. 125

max. 1,000 m at 0.8 mm2

Emergency luminaires with order suffix .04

Bus line type: e. g. J-Y(St)Y 2 x 2 x 0.8

No. of lumi-naires

per line

Max. line length

Min. cross-section

of bus line

Cable type, e.g.:

40 1,000 m 0.5 mm2 J-Y(St) Y 2 x 2 x 0.8 mm (one core)

80 1,000 m 1.0 mm2 J-Y(St) Y 2 x 2 x 0.8 mm (two cores)

125 1,000 m 1.5 mm2 J-Y(St) Y 4 x 2 x 0.8 mm (three cores)

Page 21: Emergency Lighting A1

19

EMERgENCY LIghTINg | SELf-CoNTAINED MoNIToRINg SYSTEMS

Tender texts available upon request | Specifications subject to alteration

System description

The MWEBplus system allows for continuous central control of self-contained emergency luminaires, which report their momentary states to a PC, which evaluates and controls the entire system. An immediate and clear overview of the entire system can thus be provided and be used for determining the operational readiness of the emergency lighting system.

The system is very easy to set up. 125 self-contained emergency luminaires can be installed according to the general circuit diagram indicated on page 18.

The communication line does not need to comply with any particular requirements; its structure can be T-shaped, star-shaped, linear or even mixed.

MWEBplus constitutes the interface between the system’s oS and an on-site Ethernet network. Since MWEBplus performs the entire control and error management of the emergency lighting system, a separate PC for the monitoring system is not required.

The MWEBplus module can be accessed via web navigator from any PC in the network that is connected to intranet/internet, without the need for any special software.

for this purpose, the data stored in MWEBplus are transmitted to the navigator via TCP/IP protocol.

Any malfunction within the system will be immediately displayed; the incorporated e-mail function allows detailed information on the malfunction to be sent to the system administrator. The system can also be accessed via internet if the network is configured accordingly.

Monitoring module MWEBplus 671823.000 L 160, B 110, h 63

MWEBplus

H

B

L

Page 22: Emergency Lighting A1

20

EMERgENCY LIghTINg | SELf-CoNTAINED MoNIToRINg SYSTEMS

Tender texts available upon request | Specifications subject to alteration

Monitoring via MWEBplus

Please note:

All modules and luminaires for MWEBplus must have order suffix (Y) .04

general mains power supply

L

N

MWEBplus

max. 125 luminairesmax. 1,000 m

Bus

general mains power supply

L

N

general mains power supply

L

N

Page 23: Emergency Lighting A1

21

654321

NLPE

654321

NLPE

654321

NLPE

654321

NLPE

654321

NLPE

EMERgENCY LIghTINg | SELf-CoNTAINED MoNIToRINg SYSTEMS

Tender texts available upon request | Specifications subject to alteration

Monitoring via MWEBplus

Ethernet Switch

Mains 230 V

Max. 125 luminaires Max. length: 1,000 m

Meter-BUS 30 V DC 2 x 1.5 mm2

MultiDigit® module 125

MultiDigit® module 1

MultiDigit® module 2

MultiDigit® module 3

MultiDigit® module 4

Page 24: Emergency Lighting A1

22

EMERgENCY LIghTINg | SELf-CoNTAINED MoNIToRINg SYSTEMS

System benefits

- Central monitoring of the entire system

- Simple and clear structure

- Automatic function tests

- Simple test log generation

- Easy to install

- Execution of all mandatory tests at minimum costs

- Collective error display on the monitoring unit

- Blinking codes on each luminaire indicate the type of error

Monitoring systems

PZ 50 for 50 self-contained luminaires

Self-test module or lumi-naire / ballast with order suffix .03

Up

to 5

0 em

erge

ncy

light

s!M

ax. l

engt

h of

bus

line

: 40

0 m

(tot

al le

ngth

of l

oop

wiri

ng s

yste

m!)

Type

of b

us li

ne: e

.g. J

-Y(S

t)Y 2

x2x0

.8

200 V ac BUSLoop wiring system

200 V / 50 Hz

PZ 50 monitoring systemcontinuous control of max. 50 emergency luminaires

Please note:

All modules and luminaires for PZ 50 must have order suffix (Y) .03

Page 25: Emergency Lighting A1

23

EMERgENCY LIghTINg | SELf-CoNTAINED MoNIToRINg SYSTEMS

Tender texts available upon request | Specifications subject to alteration

PZ 50Description

The feedback unit PZ 50 allows for central monitoring of self-test emergency luminaires (.03). The monitoring unit displays any error of any connected emergency luminaire as well as any BUS line disconnection. Moreover, it displays whether the power supply is on or off. It can, however, not be seen which of the luminaires is involved in the failure.

Up to 50 luminaires can be connected to one control unit via a loop wiring system.

Suitable cable type for this system is for example cable J-Y(ST)-Y 2 x 2 x 0.8. Attention: bus line voltage may reach up to 200 V. The maximum line length amounts to 400 meters, which means that the farest distance between any luminaire and the control unit may be max. 200 meters. The BUS line must not be conducted thorough the same cable through which the power supply line is conducted.

Functioning

Automatic luminaire self-test

The emergency luminaires are fitted with additional automatic self-test electronics for testing the luminaire itself, the battery and the lamp of the luminaire, following an optimized testing programme defined for these luminaires. The testing result will be transformed into a visual and audible alarm.

Benefits of autonomous self-test electronics:

- high reliability- Low maintenance- Ease of use- Time saving testing and controlling process

Any malfunction within the system will be displayed on the unit as a collective malfunction, which can be forwarded to any superior system via a potential-free contact (230 V AC/5 A or 24 V/5 A).

Monitoring system for RZB self-contained emergency luminaires with order suffix .03

Type of protection: IP 20

Protection class: I

Power supply: 230 V / 50/60 hz

Power supply (bus line): 200 V

Alarm delay: 10 seconds

Dimensions: L 158, h 90, T 58

Type of installation: DIN profile track

Max. bus line length: 400 m

Max. no. of luminaires that can be monitored: 50 luminaires

Potential-free contact: 230 V AC / 5 A 24 V DC / 5 A

Monitoring system PZ 50671466.009 L 158, h 90, T 58

H

B

L

Page 26: Emergency Lighting A1

24

Page 27: Emergency Lighting A1

25

Self-contained emergency luminairesTenuo 26LED Halyxx® 28GSUN® S 32Ilustris 34Display 36Flat Sign Mini/Midi 38Design 40Rechteck 250 / 360 / 485 44Multivariabel 50Signcube 52GSUN® 2 55 GSUN® 2 LED 55GSUN® 3 56GSUN® 3 LED 57GSUN® 4 58GSUN® 4 LED 59LCS1 60LCS3 60Varioplast I 62Space 64Universum 66Turia 68Edo 70Lucio 72Centryxx 74Energo TC 175 76Energo TC 210 78Andho TC 80Andho TC IP 65 82Arelo® 84Mondana 86Flat Polymero® 88Flat Polymero® PC with collar 90Flat Basic 92Flat Basic with collar 94Flat Polymero® Rechteck 96Basic 98Kreis 100Rondo 102Rounded® Maxi 104Alu‑Rund 106Weatherproof battens 108Hand‑held LED safety spotlight 110Safety stand spotlight 110

28, 30 - 31 28, 30 - 31 32

44, 47 50 52

38 40 - 4340 - 43

74

54, 56 - 57 54, 58 - 59 54, 58 - 59

76 - 79

94

96

106

64 6866

44, 45

26 28 - 29

44, 46

6054, 55

70

72

62

88

102

110

90

104

92

100

110

98

108

80 - 83 84

86

3634

LED LED LED LED LED

LED

LED LED LED

LEDLED LED

LED LED

LED

LED

LED

LED

8h 8h 8h

8h

8h 8h 8h

Page 28: Emergency Lighting A1

26

EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES

Motifs For escape route identification – Building and workplace legislation Legends in accordance with DIN 4844, UVV BGV A8 and EECR 92/58 Background colour: green

Tenuo Type of protection: IP 40

- The flattest existing emergency luminaire that incorporates the very latest energy saving LED technology

- Ultraflat - (panel 5 mm) frame 8 mm

- Energy efficient (consumption approx. 60% less than 13 W fluorescent lamp technology)

- Top quality LED technology

- Specially calculated thermal management

- The very latest LED technology keeps maintenance costs to a minimum

- LED service life: approx. 50,000 hours

- Exceptionally high luminance of over 900 cd/m2

- Wide range of applications thanks to various types of installation

Wall extension Wall (semi‑recessed) Ceiling (surface) Ceiling (recessed) Pendant tubeSuspension cable/chain

1003

1113

1114

1004

1115

1116

1005

Page 29: Emergency Lighting A1

27

EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES

For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration

Wall (surface) Wall extension Wall (semi‑recessed) Ceiling (surface) Ceiling (recessed) Pendant tubeSuspension cable/chain

Installation scheme available on request

Installation scheme available on request

Installation scheme available on request

Installation scheme available on request

Installation scheme available on request

Installation scheme available on request

Installation scheme available on request

Article number Type of installation

Viewing distance

Luminous flux factor

Lamp/Wattage PZ 50 (.03)

MultiDigit (.04)

DALI (.07)

Rated operat‑ing time

Dimensions

671944.00X.y Wall (surface) 30 m ‑ 1 x LED 2,5 W ‑ ‑ • 3 h L 350, B 33, H 200

671945.00X.y Wall extension 30 m ‑ 1 x LED 5 W ‑ ‑ • 3 h L 400, B 60, H 200

671943.00X.y Wall (semi‑recessed) 30 m ‑ 1 x LED 2,5 W ‑ ‑ • 3 h L 350, B 11, H 200,

LA 173, BA 173, TE 70

671946.00X.y Ceiling (surface) 30 m ‑ 1 x LED 5 W ‑ ‑ • 3 h L 350, B 50, H 240

671947.00X.y Ceiling (recessed) 30 m ‑ 1 x LED 5 W ‑ ‑ • 3 h L 420, B 40, H 252, LA 400, BA 40, HE 90

671948.00X.y Pendant tube 30 m ‑ 1 x LED 5 W ‑ ‑ • 3 h L 350, B 50, H 200, LP 500

671949.00X.y Suspension cable/chain 30 m ‑ 1 x LED 5 W ‑ ‑ • 3 h L 350, B 50, H 200,

LP 500

Series: Tenuo

Type of protection: IP 40 Protection class: I Viewing distance: 30 m

For escape route identification

Housing: aluminium, silver. Display panel with patented MicroLens technology.

LED included.

Please indicate symbol number when placing your order!

operating mode: Can either be connected in non‑maintained power mode (BS) or in maintained power mode (DS).

Ballast mains/emergency: EB

Available colour (X): 4 = aluminium, anodised

30 m

H

L B

H

L B

HA

L TE

H

LA

B

H

L B

H

L

LAB

BA

HE

LP

L B

H

LP

L B

H

Page 30: Emergency Lighting A1

28

EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES

Wall (surface) Ceiling (surface) Ceiling (recessed) Wall (recessed)

8hfor

accomodation facilities, nursing homes and

multi-storey buildings

(only in Germany)

Motifs For escape route identification – Building and workplace legislation Legends in accordance with DIN 4844, UVV BGV A8 and EECR 92/58 Background colour: green

LED Halyxx® Type of protection: IP 40

- High quality aluminium housing

- High quality and elegant design

- Energy efficient (consumption approx. 60% less than 13 W fluorescent lamp technology)

- Specially calculated thermal management

- The very latest LED technology keeps maintenance costs to a minimum

- LED service life: approx. 50,000 hours

- Luminance exceeds 500 cd/m2

- Wide range of applications thanks to various types of installation

- Moulded housing for concrete available

- Easy to install

1003

1113

1114

1004

1115

1116

1005

Page 31: Emergency Lighting A1

29

EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES

For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration

Wall (surface) Ceiling (surface) Ceiling (recessed) Wall (recessed) (cavity wall) Wall (recessed) (solid wall)

Article number Type of installation

Viewing distance

Luminous flux factor

Lamp/Wattage PZ 50 (.03)

MultiDigit (.04)

DALI (.07)

Rated operat‑ing time

Dimensions

671501.00X.y Wall (surface) 14 m ‑ 4 x LED 1 W • • • 3 h L 233, B 40, H 180

671502.00X.y Ceiling (surface) 14 m ‑ 4 x LED 1 W • • • 3 h L 233, B 40, H 180

671518.00X.y Ceiling (recessed) 14 m ‑ 4 x LED 1 W • • • 3 h L 270, B 55, H 100

LA 255 x BA 42, HE 90

671546.12X.y Wall (recessed) (cavity wall) 14 m ‑ 1 x LED 4 W • • – 3 h L 220, B 2, H 150

LA 210 x BA 132, HE 90

671546.00X.y Wall (recessed) (solid wall) 14 m ‑ 1 x LED 4 W • • – 3 h L 220, B 2, H 150

LA 200 x BA 130, HE 80

Series: LED Halyxx®

Type of protection: IP 40 Protection class: I Viewing distance: 14 m Ceiling thickness: 5‑35 mm Wall thickness: 1‑30 mm

For escape route identification

Base: aluminium extrusion profile; display panel: highly transparent panel with motifs on one side/both sides.

LED included.

Please specify legend number when ordering!

operating mode: Can either be connected in non‑maintained power mode (BS) or in maintained power mode (DS).

Ballast mains/emergency: EB

Available colours (X): 2 = white (only Wall (recessed)) 4 = aluminium, anodised (all variants)

Mounting set for suspension cable/chainViewing distance: 14 m981701.004 L 213, B 33, H 77 for art. 671502.004.y

Moulded housingViewing distance: 14 m981685.000 L 542, B 142, H 143 for art. 671518.004.y

Accessories | Pendant set for ceiling luminairesPendant length 500 mm (other lengths upon request), white plastic canopy, chrome suspension tube, length: 480 mm, can be shortened on site.

Pendant setsViewing distance: 14 m981639.010 for art. 671502.004981639.030 for art. 671502.004.03981639.040 for art. 671502.004.04/.07

Wall extensionViewing distance: 14 m981581.004 L 258, B 38, H 104 for art. 671502.004.y

14 m

H

L B

H

L B

H

LLA

BBA

HE5-

35

3

180

151233

4523Ø4,5

15

15

150233

Ø5

12,550

1640

4255

255270

HA

LHE

1-30

H

LA

BL

HA

HE

LA

B

H

132150

210220

130150

200220

Page 32: Emergency Lighting A1

30

EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES

Series: LED Halyxx®

Type of protection: IP 40 Protection class: I Viewing distance: 19 m Ceiling thickness: 5‑35 mm

For escape route identification

Base: aluminium extrusion profile; display panel: highly transparent panel with motifs on one side/both sides.

LED included.

Please specify legend number when ordering!

operating mode: Can either be connected in non‑maintained power mode (BS) or in maintained power mode (DS).

Ballast mains/emergency: EB

Available colour (X): 4 = aluminium, anodised

Wall (surface) Ceiling (surface) Ceiling (recessed)

Mounting set for suspension cable/chainViewing distance: 19 m981701.004 L 213, B 33, H 77 for art. 671742.004.y

Moulded housingViewing distance: 19 m981686.000 L 542, B 142, H 143 for art. 671750.004.y

Accessories | Pendant set for ceiling luminairesPendant length 500 mm (other lengths upon request), white plastic canopy, chrome pendant tube, length: 480 mm, can be shortened on site.

Pendant setsViewing distance: 19 m981639.010 for art. 671742.004981639.030 for art. 671742.004.03981639.040 for art. 671742.004.04/.07

Wall extensionViewing distance: 19 m981581.004 L 258, B 38, H 104 for art. 671742.004.y

Article number Type of installation

Viewing distance

Luminous flux factor

Lamp/Wattage PZ 50 (.03)

MultiDigit (.04)

DALI (.07)

Rated operat‑ing time

Dimensions

671746.00X.y Wall (surface) 19 m ‑ 4 x LED 1 W • • • 3 h L 235, B 40, H 220

671895.00X.y Wall (surface) 19 m ‑ 4 x LED 1 W • • ‑ 8 h L 235, B 40, H 220

671742.00X.y Ceiling (surface) 19 m ‑ 4 x LED 1 W • • • 3 h L 235, B 40, H 220

671896.00X.y Ceiling (surface) 19 m ‑ 4 x LED 1 W • • ‑ 8 h L 235, B 40, H 220

671750.00X.y Ceiling (recessed) 19 m ‑ 4 x LED 1 W • • • 3 h L 320, B 55, H 140 LA 305 x BA 42, HE 90

671897.00X.y Ceiling (recessed) 19 m ‑ 4 x LED 1 W • • ‑ 8 h L 320, B 55, H 140 LA 305 x BA 42, HE 90

For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration

19 m

H

L B

H

L B

H

L LA

B BA

HE

5-35

3

220

151235

4523

Ø4,5

15

15

150

233Ø5

12,5

50

1640

4255

305320

Page 33: Emergency Lighting A1

31

EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES

For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration

Series: LED Halyxx®

Type of protection: IP 40 Protection class: I Viewing distance: 30 m Ceiling thickness: 5‑35 mm

For escape route identification

Base: aluminium extrusion profile; display panel: highly transparent panel with motifs on one side/both sides.

LED included.

Please specify legend number when ordering!

operating mode: Can either be connected in non‑maintained power mode (BS) or in maintained power mode (DS).

Ballast mains/emergency: EB

Available colour (X): 4 = aluminium, anodised

Wall (surface) Ceiling (surface) Ceiling (recessed)

Mounting kit for chains/cable suspensionsViewing distance: 30 m981702.004 L 318, B 33, H 57 for art. 671744.004.y

Moulded housingViewing distance: 30 m981687.000 L 542, B 142, H 143 for art. 671752.004.y

Accessories | Pendant set for ceiling luminairesPendant length 500 mm (other lengths upon request), white plastic canopy, chrome pendant tube, length: 480 mm, can be shortened on site.

Pendant setsViewing distance: 30 m981647.010 for art. 671744.004981647.030 for art. 671744.004.03981647.040 for art. 671744.004.04/.07

Wall extensionViewing distance: 30 m981640.000 L 363, B 38, H 104 for art. 671744.004.y

Article number Type of installation

Viewing distance

Luminous flux factor

Lamp/Wattage PZ 50 (.03)

MultiDigit (.04)

DALI (.07)

Rated operat‑ing time

Dimensions

671748.00X.y Wall (surface) 30 m ‑ 4 x LED 1 W • • • 3 h L 340, B 40, H 270

671912.00X.y Wall (surface) 30 m ‑ 4 x LED 1 W • • ‑ 8 h L 340, B 40, H 270

671744.00X.y Ceiling (surface) 30 m ‑ 4 x LED 1 W • • • 3 h L 340, B 40, H 270

671913.00X.y Ceiling (surface) 30 m ‑ 4 x LED 1 W • • ‑ 8 h L 340, B 40, H 270

671752.00X.y Ceiling (recessed) 30 m ‑ 4 x LED 1 W • • • 3 h L 424, B 55, H 190 LA 410 x BA 42, HE 90

671914.00X.y Ceiling (recessed) 30 m ‑ 4 x LED 1 W • • ‑ 8 h L 424, B 55, H 190 LA 410 x BA 42, HE 90

30 m

H

L B

H

L B

H

L LA

B BA

HE

5-35

3

270

250340

4523

Ø4,5

15

25

40

270340

25

Ø510,5

27,5

4255

410424

Page 34: Emergency Lighting A1

32

EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES

Ceiling (surface)Wall (surface)

GSUN® S Type of protection: IP 20

- Housing made of top quality aluminium

- Energy efficient (consumption approx. 80% less than 13 W fluorescent lamp technology)

- The very latest LED technology keeps maintenance costs to a minimum

- LED service life: approx. 50,000 hours

- Standard automatic self-test

- Set of 3 easily attachable pictograms

- Easy to install

- Suitable for mounting on either a ceiling or a wall by simply changing the end caps

90°

90°

Page 35: Emergency Lighting A1

33

EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES

For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration

Ceiling (surface)Wall (surface)

Pendant tube981777.014 Pendant lenght 500 mm

Wall extension981779.004 L 260, B 45, H 110

Suspension cable/chain981780.000 Pendant lenght 1500 mm

Article number Type of installation

Viewing distance

Luminous flux factor

Lamp/Wattage PZ 50 (.03)

MultiDigit (.04)

DALI (.07)

Rated operat‑ing time

Dimensions

671915.00X.y Wall (surface), Ceiling (surface) 24 m ‑ 1 x LED 1 W with automatic self‑test function,

without feedback 3 h L 240, B 45, H 190

Series: GSUN® S

Type of protection: IP 20 Protection class: I Viewing distance: 24 m

For escape route identification

Housing: extruded aluminium profile, with universal installation set for ceiling and wall surface mounting. 3 foils with escape route motif and 1 white foil included for attachment. Automatic self test in all standard versions.

operating mode: Can either be connected in non‑maintained power mode (BS) or in maintained power mode (DS).

LED included.

Ballast mains/emergency: EB

Available colour (X): 4 = silver coloured

24 m

H

L B

15

H

L B

15

175

240200

5,5x10

22,5

45

200

5,5x10

Page 36: Emergency Lighting A1

34

EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES

Wall (surface) Ceiling (surface)

Ilustris Type of protection: IP 20

- Design matches modern architectural styles

- Energy efficient (consumption approx. 60% less than 13 W fluorescent lamp technology)

- The very latest LED technology keeps maintenance costs to a minimum

- LED service life: approx. 50,000 hours

- Large viewing distance

- Standard automatic self-test

- Wide range of applications thanks to various types of installation

Page 37: Emergency Lighting A1

35

EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES

For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration

Wall (surface) Ceiling (surface)

Article number Type of installation

Viewing distance

Luminous flux factor

Lamp/Wattage PZ 50 (.03)

MultiDigit (.04)

DALI (.07)

Rated operat‑ing time

Dimensions

671842.00X.y Wall (surface) 30 m ‑ 1 x LED 3 W with automatic self‑test function, without feedback

3 h L 368, B 55, H 253

671846.00X.y Ceiling (surface) 30 m ‑ 1 x LED 3 W 3 h L 368, B 27, H 263

Pendant tube981777.0031 Pendant lenght 500 mm

Suspension cable/chain981776.000 Pendant lenght 1500 mm –

Wall extension981775.0031 L 300, B 150, H 35 –

Series: Ilustris

Type of protection: IP 20 Protection class: I Viewing distance: 30 m

For escape route identification

Housing: die‑cast aluminium, powder‑coated. 3 foils with escape route motif and 1 white foil included. Automatic self test in all standard versions.

LED included.

operating mode: Can either be connected in non‑maintained power mode (BS) or in maintained power mode (DS).

Ballast mains/emergency: EB

Available colour (X): 31 = anthracite metallic

30 m

H

L B

H

L B

Ø5,5

120

150

368

253

35 5522

5,5x10

100368

26

Page 38: Emergency Lighting A1

36

EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES

Ceiling (surface)Wall (surface) Ceiling (recessed)

Motifs For escape route identification – Building and workplace legislation Legends in accordance with DIN 4844, UVV BGV A8 and EECR 92/58 Background colour: green

Display Type of protection: IP 40

- Absolutely uniform illumination of the motifs

- Wide range of applications thanks to various types of installation

- Designed for large viewing distances

- Standard fluorescent lamps can be used

- Specifically calculated reflector inside the luminaire

1003

1113

1114

1004

1115

1116

1005

Page 39: Emergency Lighting A1

37

EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES

For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration

Ceiling (surface)Wall (surface) Ceiling (recessed)

Accessories | Wall extensionSteel bracket, white powder‑coated

Wall extension981489.002

Article number Type of installation

Viewing distance

Luminous flux factor

Lamp/Wattage PZ 50 (.03)

MultiDigit (.04)

DALI (.07)

Rated operat‑ing time

Dimensions

671005.75X.y Wall (surface) 32 m ‑ 1 x T16 (T5) 8 W • • ‑ 3 h L 332, B 70, H 236

671001.75X.y Ceiling (surface) 32 m ‑ 1 x T16 (T5) 8 W • • ‑ 3 h L 332, B 57, H 305

671003.75X.y Ceiling (recessed) 32 m ‑ 1 x T16 (T5) 8 W • • ‑ 3 h L 400, B 80, H 180

LA 380 x BA 68, HE 165

Series: Display

Type of protection: IP 40 Protection class: I Viewing distance: 32 m

For escape route identification

Base: metal, powder‑coated. Display panel: plastic, with motifs on one side/on both sides.

Lamp included.

Please specify legend number when ordering!

operating mode: Can either be connected in non‑maintained power mode (BS) or in maintained power mode (DS).

Ballast mains/emergency: EB

Available colours (X): 2 = white, 4 = silver metallic

Accessories | Pendant setSuspension tube, square: 40 x 40 mm, powder‑coated, suspension length 500 mm (other lengths available upon request)

Pendant set90‑3757.002 Pendant length 500 mm white90‑3757.004 Pendant length 500 mm silver metallic

Moulded housing98186.000

32 m

H

L B

H

L B

H

HE1-40

L

LA BA

B

5716

9618

332276

5x8

125236

5160

332

248

5x8 84

400

68

380

Page 40: Emergency Lighting A1

38

EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES

Pendant tubeWall (surface)

Motifs For escape route identification – Building and workplace legislation Legends in accordance with DIN 4844, UVV BGV A8 and EECR 92/58 Background colour: green

Flat Sign Mini/Midi Type of protection: IP 43

- Exclusive luminaire design

- Energy efficient (consumption approx. 60% less than 13 W fluorescent lamp technology)

- Top quality LED technology

- Uniform light distribution provided by special LED arrangement

- 2 different housing dimensions for different viewing distances

1003

1113

1114

1004

1115

1116

1005

Page 41: Emergency Lighting A1

39

EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES

For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration

Pendant tubeWall (surface) Mini Wall (surface) Midi

Article number Type of installation

Viewing distance

Type Lamp/Wattage PZ 50 (.03)

MultiDigit (.04)

DALI (.07)

Rated operat‑ing time

Dimensions

671558.00X.y Wall (surface) 21 m Mini 4 x LED 0,5 W • • ‑ 3 h L 237, B 84, H 125

671559.00X.y Wall (surface) 32 m Midi 4 x LED 0,5 W • • ‑ 3 h L 348, B 84, H 178

671560.00X.y Pendant tube 21 m Mini 4 x LED 1 W • • ‑ 3 h L 237, B 138, H 125, LP 480

671615.00X.y Pendant tube 32 m Midi 6 x LED 1 W • • ‑ 3 h L 348, B 138, H 178, LP 480

Series: Flat Sign Mini/Midi

Type of protection: IP 43 Protection class: I Viewing distance: 21 m, 32 m

For escape route identification

Housing: sheet steel, powder‑coated; display panel: plastic, opal, with motifs on one side/on both sides.

LED included.

Please specify legend number when ordering!

operating mode: Can either be connected in non‑maintained power mode (BS) or in maintained power mode (DS).

Ballast mains/emergency: EB

Available colour (X): 2 = white

21 m/32 m

LP

L B

H

H

L B

H

L B

60

10

Ø10

Ø3,530

120

27

237

Ø20

9x5125

8

237

27

348

Ø20

9x5178

Page 42: Emergency Lighting A1

40

EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES

Pendant tubeCeiling (surface)Ceiling (surface), Wall (surface)

Wall (surface) Wall extension

8hfor

accomodation facilities, nursing homes and

multi-storey buildings

(only in Germany)

Motifs For escape route identification – Building and workplace legislation Legends in accordance with DIN 4844, UVV BGV A8 and EECR 92/58 Background colour: green

Design Type of protection: IP 40

- Flat aluminium housing in elegant design

- Installation-friendly design enables lamp replacement without tools

- Designed for large viewing distances

- Wide range of applications thanks to various types of installation

- Luminaire also available for escape route illumination

1003

1113

1114

1004

1115

1116

1005

Page 43: Emergency Lighting A1

41

EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES

For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration

Wall (surface) Wall extension Pendant tubeCeiling (surface)

Article number Type of installation

Viewing distance

Luminous flux factor

Lamp/Wattage PZ 50 (.03)

MultiDigit (.04)

DALI (.07)

Rated operat‑ing time

Dimensions

671590.75X.y Wall (surface) 26 m ‑ 1 x T16 (T5) 6 W • • ‑ 3 h L 294, B 55, H 190

671594.75X.y Wall extension 26 m ‑ 1 x T16 (T5) 6 W • • ‑ 3 h L 314, B 55, H 190

671592.75X.y Ceiling (surface) 26 m ‑ 1 x T16 (T5) 6 W • • ‑ 3 h L 340, B 55, H 232

671596.75X.y Pendant tube 26 m ‑ 1 x T16 (T5) 6 W • • ‑ 3 h L 340, B 55, H 190, LP 524

Series: Design

Type of protection: IP 40 Protection class: I Viewing distance: 26 m

For escape route identification

Housing: aluminium, powder‑coated. Display panels: plastic, opal, with motifs on one side/on both sides.

Lamp included.

Please specify legend number when ordering!

operating mode: Can either be connected in non‑maintained power mode (BS) or in maintained power mode (DS).

Ballast mains/emergency: EB

Available colour (X): 2 = white

Accessories | Wire guardBall impact proof in accordance with DIN 18032, Part 3 and DIN VDE 0710, Part 13

Wire guard and bracket: steel, white, powder‑coated. Wire guard mounted with screws, can be opened for luminaire maintenance.

Wire guard for wall luminaires981167.002 L 380, B 295, H 185

26 m

H

L B

H

B L

LP

H

L B

H190

L B

90

15

210

294

190

27

19075

55

18

5,5x106 6

340

8260

82Ø6

5542

52,5 52,5

340169,5

5x12

Page 44: Emergency Lighting A1

42

EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES

Wall (surface) Wall extension Pendant tubeCeiling (surface)

Article number Type of installation

Viewing distance

Luminous flux factor

Lamp/Wattage PZ 50 (.03)

MultiDigit (.04)

DALI (.07)

Rated operat‑ing time

Dimensions

671017.75X.y Wall (surface) 33 m ‑ 1 x T16 (T5) 8 W • • ‑ 3 h L 370, B 55, H 228

671588.75X.y Wall (surface) 33 m ‑ 1 x T16 (T5) 8 W • • ‑ 8 h L 370, B 55, H 228

671023.75X.y Wall extension 33 m ‑ 1 x T16 (T5) 8 W • • ‑ 3 h L 390, B 55, H 228

671219.75X.y Ceiling (surface) 33 m ‑ 1 x T16 (T5) 8 W • • ‑ 3 h L 416, B 55, H 270

671717.75X.y Ceiling (surface) 33 m ‑ 1 x T16 (T5) 8 W • • ‑ 8 h L 416, B 55, H 270

671311.75X.y Pendant tube 33 m ‑ 1 x T16 (T5) 8 W • • ‑ 3 h L 416, B 55, H 228, LP 500

For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration

Series: Design

Type of protection: IP 40 Protection class: I Viewing distance: 33 m

For escape route identification

Housing: aluminium, powder‑coated. Display panels: plastic, opal, with motifs on one side/on both sides.

Lamp included.

Please specify legend number when ordering!

operating mode: Can either be connected in non‑maintained power mode (BS) or in maintained power mode (DS).

Ballast mains/emergency: EB

Available colour (X): 2 = white

Accessories | Wire guardBall impact proof in accordance with DIN 18032, Part 3 and DIN VDE 0710, Part 13

Wire guard and bracket: steel, white, powder‑coated. Wire guard mounted with screws, can be opened for luminaire maintenance.

Wire guard for wall luminaires981168.002 L 540, B 375, H 185

33 m

H

L B

H

B L

LP

H

L B

H228

L B

117 22847

283

28370

6x16

22890

55

5x10

18

6 6416

8260

82Ø6

5542

53 53

416208

5x12

Page 45: Emergency Lighting A1

43

EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES

For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration

Wall (surface), Ceiling (surface) 8 W Wall (surface), Ceiling (surface) 18 W Wall (surface), Ceiling (surface) 36 W Wall (surface), Ceiling (surface) 58 W

Planning guide: Escape route illumination in accordance with EN 1838

E = 1 lx along the centre line

Spacing table 671586.752

Lamp luminous flux:

Mains: 1350 lm, Emergency: 540 lm

The following values are indicated in m

h a b c d

2.5 8.5 3.6 11.2 4.8

3.0 9.0 3.9 12.1 5.1

3.5 9.6 4.1 13.4 5.4

4.0 10.8 4.3 14.3 5.6

Spacing table 671009.752

Lamp luminous flux:

Mains: 450 lm, Emergency: 185 lm

The following values are indicated in m

h a b c d

2.5 7.0 2.7 9.0 3.5

3.0 7.4 2.8 9.4 3.5

3.5 7.6 2.8 9.8 3.5

4.0 7.6 2.6 10.0 3.4

Spacing table 671013.752

Lamp luminous flux:

Mains: 3350 lm, Emergency: 469 lm

The following values are indicated in m

h a b c d

2.5 8.8 3.7 14.0 5.8

3.0 9.4 3.9 12.4 5.0

3.5 10.1 4.0 13.2 5.3

4.0 10.9 4.2 14.0 5.4

Spacing table 671011.752

Lamp luminous flux:

Mains: 1350 lm, Emergency: 243 lm

The following values are indicated in m

h a b c d

2.5 7.3 2.9 9.6 3.8

3.0 7.8 3.0 10.1 3.9

3.5 8.2 3.1 10.6 4.0

4.0 8.4 3.0 11.0 4.0

Spacing table 671447.752

Lamp luminous flux:

Mains: 5200 lm, Emergency: 416 lm

The following values are indicated in m

h a b c d

2.5 8.6 3.5 11.2 4.6

3.0 9.2 3.7 12.0 4.8

3.5 9.7 3.9 12.8 5.1

4.0 10.4 4.0 13.4 5.2

Article number Type of installation

Viewing distance

Luminous flux factor

Lamp/Wattage PZ 50 (.03)

MultiDigit (.04)

DALI (.07)

Rated operat‑ing time

Dimensions

671009.75X.y Ceiling (surface), Wall (surface) ‑ 41 % 1 x T16 (T5) 8 W • • ‑ 3 h L 370, B 228, H 55

671011.75X.y Ceiling (surface), Wall (surface) ‑ 20 % 1 x T26 (T8) 18 W • • ‑ 3 h L 695, B 228, H 55

671586.75X.y Ceiling (surface), Wall (surface) ‑ 40 % 1 x T26 (T8) 18 W • • ‑ 8 h L 695, B 228, H 55

671013.75X.y Ceiling (surface), Wall (surface) ‑ 13 % 1 x T26 (T8) 36 W • • ‑ 3 h L 1305, B 228, H 55

671447.75X.y Ceiling (surface), Wall (surface) ‑ 8 % 1 x T26 (T8) 58 W • • ‑ 3 h L 1605, B 228, H 55

Accessories | Wire guardBall impact proof in accordance with DIN 18032, Part 3 and DIN VDE 0710, Part 13

Wire guard and bracket: steel, white, powder‑coated. Wire guard mounted with screws, can be opened for luminaire maintenance.

Wire guard for wall luminaires981168.002 L 540, B 375, H 185 for 8 W

Series: Design

Type of protection: IP 40 Protection class: I

For escape route illumination

Housing: aluminium, powder‑coated. Refractor: transparent plastic, prismatic. Reflector: aluminium, highly polished anodised finish, wide beam.

T16 fluorescent lamp included.

operating mode: Can either be connected in non‑maintained power mode (BS) or in maintained power mode (DS).

Ballast mains/emergency: LLB/EB

Available colour (X): 2 = white

L B

H

L B

H

L B

H

L B

H

117 22864

4444

370

6x16

117 22864

317 4444

1305

6x16

117 22864

313 4444

1605

6x16

120 22852

615

35695

6x16

h

d c b

a

Page 46: Emergency Lighting A1

44

EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES

Ceiling (surface) Suspension cable/chainPendant tubeWall (surface) Wall extension

Motifs For escape route identification – Building and workplace legislation Legends in accordance with DIN 4844, UVV BGV A8 and EECR 92/58 Background colour: green

Rechteck 250 / 360 / 485 Type of protection: IP 44

- High quality aluminium profile housing

- Installation-friendly conctruction facilitates easy lamp replacement

- Wide range of applications thanks to various types of installation

- Quick and easy to install thanks to the use of a quick-action locking mechanism for the lamp and ballast support

- Available also with exceptionally long service life and energy efficient LED technology

- LED conversion sets are available for existing luminaires

- All versions with downward light emission

1003

1113

1114

1004

1115

1116

1005

Page 47: Emergency Lighting A1

45

EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES

For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration

Ceiling (surface)Wall (surface) Pendant tube Suspension cable/chainWall extension

Article number Type of installation

Viewing distance

Luminous flux factor

Lamp/Wattage PZ 50 (.03)

MultiDigit (.04)

DALI (.07)

Rated operat‑ing time

Dimensions

671045.00X.y Wall (surface) 21 m ‑ 4 x LED 1 W • • ‑ 3 h L 250, B 125, H 140

671045.75X.y Wall (surface) 21 m ‑ 1 x T16 (T5) 6 W • • ‑ 3 h L 250, B 125, H 140

671049.00X.y Wall extension 21 m ‑ 4 x LED 1 W • • ‑ 3 h L 250, B 125, H 140

671049.75X.y Wall extension 21 m ‑ 1 x T16 (T5) 6 W • • ‑ 3 h L 250, B 125, H 140

671053.00X.y Ceiling (surface) 21 m ‑ 4 x LED 1 W • • ‑ 3 h L 250, B 125, H 140

671053.75X.y Ceiling (surface) 21 m ‑ 1 x T16 (T5) 6 W • • ‑ 3 h L 250, B 125, H 140

671057.00X.y Pendant tube 21 m ‑ 4 x LED 1 W • • ‑ 3 h L 250, B 125, H 140, LP 500

671057.75X.y Pendant tube 21 m ‑ 1 x T16 (T5) 6 W • • ‑ 3 h L 250, B 125, H 140, LP 500

671343.00X.y Suspension cable/chain 21 m ‑ 4 x LED 1 W • • ‑ 3 h L 250, B 125, H 140

671343.75X.y Suspension cable/chain 21 m ‑ 1 x T16 (T5) 6 W • • ‑ 3 h L 250, B 125, H 140

Series: Rechteck 250

Type of protection: IP 44 Protection class: I Viewing distance: 21 m

For escape route identification

Housing: aluminium, with plastic corner connectors. Display panels: plastic, opal, with motifs on one side/on both sides.

Lamp included.

Please specify legend number when ordering!

operating mode: Can either be connected in non‑maintained power mode (BS) or in maintained power mode (DS).

Ballast mains/emergency: EB

Available colours (X): 2 = white, 4 = aluminium, anodised

Accessories | Wire guardBall impact proof in accordance with DIN 18032, Part 3 and DIN VDE 0710, Part 13

Wire guard and bracket: steel, white, powder‑coated. Wire guard mounted with screws, can be opened for luminaire maintenance.

Wire guard for wall luminaires981167.002 L 380, B 295, H 185

21 m

H

40

BL

40 80

H

L B

LP

H

BL

40 40

40

H

L B

30

80

LB

4080

H

40

3340

140

250

6x1640

40

41

41

18140 80

12580

6x12 5555250

40 1212

80 68 12511

9

Ø 5 6x18 Ø 6

125

70 4x10

85250

60 125

250

50 5030

Page 48: Emergency Lighting A1

46

EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES

Article number Type of installation

Viewing distance

Luminous flux factor

Lamp/Wattage PZ 50 (.03)

MultiDigit (.04)

DALI (.07)

Rated operat‑ing time

Dimensions

671061.00X.y Wall (surface) 32 m ‑ 4 x LED 1 W • • ‑ 3 h L 362, B 125, H 192

671061.75X.y Wall (surface) 32 m ‑ 1 x T16 (T5) 8 W • • ‑ 3 h L 362, B 125, H 192

671065.00X.y Wall extension 32 m ‑ 6 x LED 1 W • • ‑ 3 h L 362, B 125, H 192

671065.75X.y Wall extension 32 m ‑ 1 x T16 (T5) 8 W • • ‑ 3 h L 362, B 125, H 192

671069.00X.y Ceiling (surface) 32 m ‑ 6 x LED 1 W • • ‑ 3 h L 362, B 125, H 192

671069.75X.y Ceiling (surface) 32 m ‑ 1 x T16 (T5) 8 W • • ‑ 3 h L 362, B 125, H 192

671073.00X.y Pendant tube 32 m ‑ 6 x LED 1 W • • ‑ 3 h L 362, B 125, H 192, LP 500

671073.75X.y Pendant tube 32 m ‑ 1 x T16 (T5) 8 W • • ‑ 3 h L 362, B 125, H 192, LP 500

671347.00X.y Suspension cable/chain 32 m ‑ 6 x LED 1 W • • ‑ 3 h L 362, B 125, H 192

671347.75X.y Suspension cable/chain 32 m ‑ 1 x T16 (T5) 8 W • • ‑ 3 h L 362, B 125, H 192

For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration

Series: Rechteck 360

Type of protection: IP 44 Protection class: I Viewing distance: 32 m

For escape route identification

Housing: aluminium, with plastic corner connectors. Display panels: plastic, opal, with motifs on one side/on both sides.

Lamp included.

Please specify legend number when ordering!

operating mode: Can either be connected in non‑maintained power mode (BS) or in maintained power mode (DS).

Ballast mains/emergency: EB

Available colours (X): 2 = white, 4 = aluminium, anodised

Accessories | Wire guardBall impact proof in accordance with DIN 18032, Part 3 and DIN VDE 0710, Part 13

Wire guard and bracket: steel, white, powder‑coated. Wire guard mounted with screws, can be opened for luminaire maintenance.

Wire guard for wall luminaires981168.002 L 540, B 375, H 185

Ceiling (surface)Wall (surface) Pendant tube Suspension cable/chainWall extension

32 m

40

3340

192

362

6x1640

40

55

55

192

40

12

12

8068

125119

Ø 5

6x18

Ø 6

5555362

40 1212

80 68 12511

9

Ø 5 6x18 Ø 6

125

70 4x10

85362

60 125

362

50 5030

H

L B

H

40

BL

40 80

LP

H

BL

40 40

40

H

L B

30

40

LB

4080

H

Page 49: Emergency Lighting A1

47

EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES

For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration

Article number Type of installation

Viewing distance

Luminous flux factor

Lamp/Wattage PZ 50 (.03)

MultiDigit (.04)

DALI (.07)

Rated operat‑ing time

Dimensions

671077.00X.y Wall (surface) 43 m ‑ 4 x LED 1 W • • ‑ 3 h L 485, B 125, H 250

671077.75X.y Wall (surface) 43 m ‑ 1 x T26 (T8) 15 W • • ‑ 3 h L 485, B 125, H 250

671081.00X.y Wall extension 43 m ‑ 6 x LED 1,4 W • • ‑ 3 h L 485, B 125, H 250

671081.75X.y Wall extension 43 m ‑ 1 x T26 (T8) 15 W • • ‑ 3 h L 485, B 125, H 250

671085.00X.y Ceiling (surface) 43 m ‑ 6 x LED 1,4 W • • ‑ 3 h L 485, B 125, H 250

671085.75X.y Ceiling (surface) 43 m ‑ 1 x T26 (T8) 15 W • • ‑ 3 h L 485, B 125, H 250

671089.00X.y Pendant tube 43 m ‑ 6 x LED 1,4 W • • ‑ 3 h L 485, B 125, H 250, LP 500

671089.75X.y Pendant tube 43 m ‑ 1 x T26 (T8) 15 W • • ‑ 3 h L 485, B 125, H 250, LP 500

671351.00X.y Suspension cable/chain 43 m ‑ 6 x LED 1,4 W • • ‑ 3 h L 485, B 125, H 250

671351.75X.y Suspension cable/chain 43 m ‑ 1 x T26 (T8) 15 W • • ‑ 3 h L 485, B 125, H 250

Series: Rechteck 485

Type of protection: IP 44 Protection class: I Viewing distance: 43 m

For escape route identification

Housing: aluminium, with plastic corner connectors. Display panels: plastic, opal, with motifs on one side/on both sides.

Lamp included.

Please specify legend number when ordering!

operating mode: Can either be connected in non‑maintained power mode (BS) or in maintained power mode (DS).

Ballast mains/emergency: EB

Available colours (X): 2 = white, 4 = aluminium, anodised

Ceiling (surface)Wall (surface) Pendant tube Suspension cable/chainWall extension

43 m

H

40

BL

40 80

40

H

L B

30

LP

H

L B

40 40

H

L B

40

LB

4080

H

5555485

40 1212

80 68 12511

9

Ø 5 6x18 Ø 6

125

485

50 5030

125

4x10

4855050

70 85

60

40

3340

250

485

6x1640

40

55

55

250

40

12

12

8068

125119

Ø 5

6x18

Ø 6

Page 50: Emergency Lighting A1

48

EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES

Accessories | Sets for converting luminaires for LED lampsProtection class: I Low‑cost conversion of rectangular luminaires with T16 (or 8 W / 15 W) or common incandescent lamps into luminaires with energy‑efficient, long‑life LEDs. The conversion set can be clicked in any existing housing without needing to use any tool and can be connected to the existing power sup‑ply cable.Modules’ plate: powder‑coated aluminium sheet, ballasts and connecting terminal included. Monitoring function standard.operating mode: Can either be connected in non‑maintained power mode (BS) or in maintained power mode (DS).

Sets for converting luminaires of series „Rechteck 250“ for LED lamps 981724.002 single sided/double sided 4 x LED 1 W/3h981724.002.03 single sided/double sided 4 x LED 1 W/3h981724.002.04 single sided/double sided 4 x LED 1 W/3h

Sets for converting luminaires of series „Rechteck 360“ for LED lamps 981726.002 single sided 4 x LED 1 W/3h981726.002.03 single sided 4 x LED 1 W/3h981726.002.04 single sided 4 x LED 1 W/3h981728.002 double sided 6 x LED 1 W/3h981728.002.03 double sided 6 x LED 1 W/3h981728.002.04 double sided 6 x LED 1 W/3h

Sets for converting luminaires of series „Rechteck 485“ for LED lamps 981773.002 single sided 4 x LED 1 W/3h981773.002.03 single sided 4 x LED 1 W/3h981773.002.04 single sided 4 x LED 1 W/3h981774.002 double sided 6 x LED 1,4 W/3h981774.002.03 double sided 6 x LED 1,4 W/3h981774.002.04 double sided 6 x LED 1,4 W/3h

you can start right now to convert existing emergency luminaires of series Rechteck 250, 360 and 485 from incandescent or fluorescent lamp versions to LED versions.

HOW?

It‘s quite simple and easy: just use our LED conversion kits for self-contained emergency luminaires.

It’s so easy to save money

LED conversion kits

Very easy „press and clip“ mounting. The conversion kit can be inserted in any existing luminaire housing without needing any tool NoR screws:

... press them together and ... ... click them into the luminaire housing.Just take the metal brackets ...

For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration

Page 51: Emergency Lighting A1

49

EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES

For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration

The correct arrangement of the LEDs was calculated by our photometry lab, which allows us to minimize the number of LEDs, without impairing the required luminance values laid down in DIN 4844, Part 1 (luminance of more than 500 cd/m2 for the contrast colour).

Thanks to a clever heat management, we are able to drastically reduce heat stress fort he LEDs, preventing thus an early LED failure.

Average LED service life: approx. 50,000 hours!

Energy efficiency and costs

= costs for power supply

= costs for lamps

= lamp replacement costs

Costs comparison over a period of 5 years

Rechteck 360 in maintained mode (24h/day) LED Fluorescent lamp Incandescent lamp

Lamp wattage 4 W 8 W 2 x 25 W

Service life in hours 50,000 h 3 000 h 1,000 h

Total consumption in 1 year (8,760 h) in kWh 35.04 kWh 70.08 kWh 438.00 kWh

Power supply costs in 1 year (at 0.19 €/kWh) 6.66 € 13.32 € 83.22 €

Total consumption in 5 years (43,800 h) in kWh 175.20 kWh 350.40 kWh 2,190.00 kWh

Power supply costs in 5 years (at 0.19 €/kWh) 33.29 € 66.58 € 416.10 €

Number of lamps needed in 5 years (43,800 h) 0 14 43

Costs for lamps in 5 years 0.00 € 107.10 € 118.68 €

Average time needed for replacing a lamp (minutes) 15 min. 10 min. 10 min.

Costs for replacing lamps (caretaker 25.00 €/h) 0.00 € 58.33 € 179.17 €

Total costs in 5 years (power supply, lamps, lamp replacement) 33.29 € 232.01 € 713.95 €

Incandescent lamps 2 x 25 W713.95 €

LED 4 W

33.29 €

T168 W

232.01 €

Page 52: Emergency Lighting A1

50

EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES

Ceiling (surface), Wall (surface) Ceiling (surface), Wall (surface) Pendant tube

Multivariabel Type of protection: IP 54

- Industrial Design

- IP 54 type of protection - dustproof and protected against water spray

- Quick and easy to install thanks to the use of a quick-action locking mechanism for the lamp and ballast support

- Different types of installation for one sole luminaire

- Lamp replacement without tools

- Easy to install

Page 53: Emergency Lighting A1

51

EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES

For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration

Ceiling (surface), Wall (surface) Pendant tube

Spacing table 671467.752

Lamp luminous flux:

Mains: 450 lm, Emergency: 144 lm

The following values are indicated in m

h a b c d

2.5 4.8 1.5 6.2 2.0

3.0 4.6 1.1 6.0 1.7

3.5 ‑ ‑ ‑ ‑

4.0 ‑ ‑ ‑ ‑

Article number Type of installation

Viewing distance

Luminous flux factor

Lamp/Wattage PZ 50 (.03)

MultiDigit (.04)

DALI (.07)

Rated operat‑ing time

Dimensions

671467.75X.y Ceiling (surface), Wall (surface) ‑ 32 % 1 x T16 (T5) 8 W • • ‑ 3 h L 370, B 130, H 130

671368.75X.y Ceiling (surface), Wall (surface) 22 m ‑ 1 x T16 (T5) 8 W • • ‑ 3 h L 370, B 130, H 130

671370.75X.y Pendant tube 22 m ‑ 1 x T16 (T5) 8 W • • ‑ 3 h L 370, B 130, H 130, LP 500

Series: Multivariabel

Type of protection: IP 54 for indoor use Protection class: I Viewing distance: 22 m

For escape route identification or escape route illumination

Base: aluminium, powder‑coated; diffuser: plastic, opal, 3 Foils for escape route identification included.

Lamp included.

operating mode: Can either be connected in non‑maintained power mode (BS) or in maintained power mode (DS).

Ballast mains/emergency: EB

Available colour (X): 2 = white

Accessories | Wire guardBall impact proof in accordance with DIN 18032, Part 3 and DIN VDE 0710, Part 13

Wire guard and bracket: steel, white, powder‑coated. Wire guard mounted with screws, can be opened for luminaire maintenance.

Wire guard for wall luminaires981168.002 L 540, B 375, H 185

Planning guide: Escape route illumination in accordance with EN 1838

E = 1 lx along the centre line

Replacement foils991058 Replacement foil (Combi) for 21 m

22 m

H

L B H

LP

L B

130

370

Ø6

40 4030 30

4520

50

80

4x14

h

d c b

a

Page 54: Emergency Lighting A1

52

EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES

Ceiling (surface), Wall (surface) Pendant tube Suspension cable/chain

Special motifs in accordance with BGV A8

Signcube Type of protection: IP 40

- Motifs on four sides

- Plastic cube (PMMA)

- Wide range of applications thanks to various types of installation

- Optimum light distribution

- Suspension can be shortened on site

- Easy to install

Page 55: Emergency Lighting A1

53

EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES

For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration

Ceiling (surface), Wall (surface) Pendant tube Suspension cable/chain

Replacement foils991116 Motif foil 240 x 240 Motif 2003991117 Motif foil 240 x 240 Motif 2004991118 Motif foil 240 x 240 Motif 2005

Accessories | Legend foils in accordance with UVV BGV A8 and EECR 92/58Viewing distance 48 m

Article number Type of installation

Viewing distance

Luminous flux factor

Lamp/Wattage PZ 50 (.03)

MultiDigit (.04)

DALI (.07)

Rated operat‑ing time

Dimensions

671605.92X.y Ceiling (surface), Wall (surface) 24 m ‑ 1 x TC‑DEL 13 W • • ‑ 3 h L 255, B 255, H 276

671606.92X.y Pendant tube 24 m ‑ 1 x TC‑DEL 13 W • • ‑ 3 h L 255, B 255, H 291, LP 510

671614.92X.y Suspension cable/chain 24 m ‑ 1 x TC‑DEL 13 W • • ‑ 3 h L 255, B 255, H 300

Series: Signcube

Type of protection: IP 40 Protection class: I Viewing distance: 24 m

For escape route identification

Base: powder‑coated metal; canopy: plastic, white; pendant tube: metal, chrome (can be shortened on site); diffuser: plastic (PMMA), opal; 3 foils included (according to DIN 4844).

operating mode: Can either be connected in non‑maintained power mode (BS) or in maintained power mode (DS).

Ballast mains/emergency: EB

Available colour (X): 2 = white 24 m

B

L

H

LP

L

Ø108

B

H

B

L

H

190

38

190

255

255

27

Ø4,5x9

60

10

Ø10

Ø3,530 110

38

107

255

255

28

2003 2004 2005

Page 56: Emergency Lighting A1

54

EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES

Wall (surface) GSUN® 2

Wall (surface) GSUN® 2 LED

Ceiling (surface), Wall (surface) GSUN® 3 / GSUN® 3 LED

Ceiling (surface), Wall (surface) GSUN® 4 / GSUN® 4 LED

Wall (surface) GSUN® 4 / GSUN® 4 LED

GSUN® 2 / GSUN® 2 LED Type of protection: IP 44

- All-plastic luminaire, shockproof

- Installation benefits for protections class II

- 3 escape route motifs included

- Low-cost installation

in addition for GSUN® 2 LED

- Reliable and long life LED technology

- LED service life: approx. 50,000 hours

- Energy efficient (consumption approx. 60% less than 13 W fluorescent lamp technology)

- Very low current consumption

GSUN® 3 / GSUN® 4 Type of protection: IP 54

- All-plastic luminaire, shockproof

- IP 54 type of protection - dustproof and protected against water spray

- Can be used for all types of installation (with accessories)

- Low current consumption

- 3 escape route motifs included

- Low-cost installation

GSUN® 3 LED / GSUN® 4 LED Schutzart: IP 54

- All-plastic luminaire, shockproof

- IP 54 type of protection - dustproof and protected against water spray

- Can be used for all types of installation (with accessories)

- Reliable and long life LED technology

- Energy efficient (consumption approx. 60% less than 13 W fluorescent lamp technology)

- LED service life: approx. 50,000 hours

- 3 escape route motifs included

- Low-cost installation

- 8 h version

Page 57: Emergency Lighting A1

55

EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES

For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration

Wall (surface) Wall (surface)

Article number Type of installation

Viewing distance

Luminous flux factor

Lamp/Wattage PZ 50 (.03)

MultiDigit (.04)

DALI (.07)

Rated operat‑ing time

Dimensions

65133 Wall (surface) 19 m ‑ 1 x Co16 5 W + 2 x D11 0.5 W ‑ ‑ ‑ 3 h L 215, B 115, H 110

671817.00X.y Wall (surface) 19 m ‑ LED 0.2 W ‑ ‑ ‑ 3 h L 215, B 115, H 110

Series: GSUN® 2

Type of protection: IP 43 Protection class: II Viewing distance: 19 m

For escape route identification

Base: plastic. Diffuser: plastic, opal. Combination foil with black rescue symbols included. Lamps included (2 x D11 0.5 W and 1 x Co16 5 W).

operating mode: Can either be connected in non‑maintained power mode (BS) or in maintained power mode (DS).

Available colour: black

Accessories | Wire guardBall impact proof in accordance with DIN 18032, Part 3 and DIN VDE 0710, Part 13

Wire guard and bracket: steel, white, powder‑coated. Wire guard mounted with screws, can be opened for luminaire maintenance.

Wire guard for wall luminaires981167.002 L 380, B 295, H 185

Series: GSUN® 2 LED

Type of protection: IP 40 Protection class: II Viewing distance: 19 m

For escape route identification

Base: plastic. Diffuser: plastic, opal. Combination foil with escape route motif included.

LED included.

operating mode: Can either be connected in non‑maintained power mode (BS) or in maintained power mode (DS).

Available colour (X): 9 = grey

19 m

H

B

L

25

25114

85 85

214

6x10

19 m

H

B

L

25

25114

85 85

214

6x10

Page 58: Emergency Lighting A1

56

EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES

Ceiling (surface), Wall (surface) (high hood)

Ceiling (surface), Wall (surface) (flat hood)

Spacing table 671321.752

Lamp luminous flux:

Mains: 300 lm, Emergency: 108 lm

The following values are indicated in m

h a b c d

2.5 3.3 1.1 4.3 0.7

3.0 ‑ ‑ ‑ ‑

3.5 ‑ ‑ ‑ ‑

4.0 ‑ ‑ ‑ ‑

Accessories | Kits for converting luminaires for LED lampsProtection class: ILow‑cost solution for converting existing GSUN® 3 luminaires with T16 6 W (or 8 W / 15 W) into lumi‑naires with energy‑efficient, long‑life LEDs. The conversion kit can be installed in any existing housing and can be connected to the existing power supply cable.operating mode: non‑maintained or maintained.

Kit for converting GSUN® 3 for LED lamps981781.000 1 x LED 2,1 W/3h

Article number Type of installation

Viewing distance

Luminous flux factor

Lamp/Wattage PZ 50 (.03)

MultiDigit (.04)

DALI (.07)

Rated operat‑ing time

Dimensions

671574.75X.y Wall (surface) 21 m 33 % 1 x T16 (T5) 6 W • • ‑ 3 h L 240, B 126, H 78

671639.75X.y Wall (surface) 21 m 38 % 1 x T16 (T5) 6 W with automatic self‑test function, without feedback 3 h L 240, B 126, H 78

671520.00X.y Ceiling (surface), Wall (surface) 21 m ‑ 1 x Co26 15 W +

2 x D11 0,5 W ‑ ‑ ‑ 3 h L 240, B 126, H 145

671321.75X.y Ceiling (surface), Wall (surface) 21 m 33 % 1 x T16 (T5) 6 W • • ‑ 3 h L 240, B 126, H 145

671618.75X.y Ceiling (surface), Wall (surface) 21 m 38 % 1 x T16 (T5) 6 W with automatic self‑test function,

without feedback 3 h L 240, B 126, H 145

For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration

Series: GSUN® 3

Type of protection: IP 54 for indoor use Protection class: II (I for .04) Viewing distance: 21 m

For escape route identification or escape route illumination

Base: plastic; diffuser: plastic, opal, motif foil included, lamp included, test button incorporated in standard version.

operating mode: Can either be connected in non‑maintained power mode (BS) or in maintained power mode (DS).

Ballast emergency/mains: EB

Available colour (X): 2 = white

Accessories | Wire guardBall impact proof in accordance with DIN 18032, Part 3 and DIN VDE 0710, Part 13

Wire guard and bracket: steel, white, powder‑coated. Wire guard mounted with screws, can be opened for luminaire maintenance.

Wire guard for wall luminaires981167.002 L 380, B 295, H 185

Accessories | Pendant tubeSuspension tube Ø 10 mm, chrome, with canopy: white, powder‑coated and mounting material, with cable hanger, power supply cable for luminaire integrated in the tube.

Pendant tube90‑4164.002 LP 500 mm

Accessories | Wall extensionSteel, white powder‑coated

Wall extension 981144.002 L 251, B 131, H 60

Planning guide: Escape route illumination in accordance with EN 1838

E = 1 lx along the centre line

21 m

H

L B

H

L B

13

13100

80 100240

70

126

5x11

13

13100

80 100240

70

126

5x11h

d c b

a

Page 59: Emergency Lighting A1

57

EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES

For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration

Ceiling (surface), Wall (surface) (high hood)

Ceiling (surface), Wall (surface) (flat hood)

Article number Type of installation

Viewing distance

Luminous flux factor

Lamp/Wattage PZ 50 (.03)

MultiDigit (.04)

DALI (.07)

Rated operat‑ing time

Dimensions

671707.00X.y Wall (surface) 21 m ‑ 1 x LED 2,1 W • • ‑ 3 h L 240, B 126, H 78

671908.00X.y Wall (surface) 21 m ‑ 1 x LED 2,1 W ‑ • ‑ 8 h L 240, B 126, H 78

671780.00X.y Ceiling (surface), Wall (surface) 21 m ‑ 1 x LED 2,1 W • • ‑ 3 h L 240, B 126, H 145

671909.00X.y Ceiling (surface), Wall (surface) 21 m ‑ 1 x LED 2,1 W ‑ • ‑ 8 h L 240, B 126, H 145

Accessories | Wire guardBall impact proof in accordance with DIN 18032, Part 3 and DIN VDE 0710, Part 13

Wire guard and bracket: steel, white, powder‑coated. Wire guard mounted with screws, can be opened for luminaire maintenance.

Wire guard for wall luminaires981167.002 L 380, B 295, H 185

Accessories | Pendant tubeSuspension tube Ø 10 mm, chrome, with canopy: white, powder‑coated and mounting material, with cable hanger, power supply cable for luminaire integrated in the tube.

Pendant tube90‑4164.002 LP 500 mm

Accessories | Wall extensionSteel, white powder‑coated

Wall extension981144.002 L 251, B 131, H 60

Series: GSUN® 3 LED

Type of protection: IP 54 for indoor use Protection class: II (I for .04) Viewing distance: 21 m

For escape route identification

Base: plastic. Diffuser: plastic, opal. Combination foil with three rescue symbols included. LED included. Test button integrated in standard version.

operating mode: Can either be connected in non‑maintained power mode (BS) or in maintained power mode (DS).

Ballast mains/emergency: EB

Available colour (X): 2 = white

H

L B

H

L B

13

13100

80 100240

70

126

5x11

13

13100

80 100240

70

126

5x11

21 m

Page 60: Emergency Lighting A1

58

EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES

Kit for converting GSUN® 4 for LED lamps981771.000 1 x LED 4,5 W/3h

Ceiling (surface), Wall (surface) (high hood) opal

Ceiling (surface), Wall (surface) (flat hood) transparent, prismatic

Spacing table 671515.752

Lamp luminous flux:

Mains: 450 lm, Emergency: 157 lm

The following values are indicated in m

h a b c d

2.5 5.7 2.3 7.2 2.6

3.0 6.3 2.3 7.4 2.6

3.5 5.7 2.3 7.0 2.5

4.0 6.5 2.1 7.1 2.1

Spacing table 671517.752

Lamp luminous flux:

Mains: 450 lm, Emergency: 157 lm

The following values are indicated in m

h a b c d

2.5 5.5 1.9 6.9 2.5

3.0 4.9 1.6 6.1 2.3

3.5 4.4 1.1 6.4 1.8

4.0 ‑ ‑ ‑ ‑

Accessories | Kits for converting luminaires for LED lamps

Protection class: ILow‑cost solution for converting existing GSUN® 4 luminaires with T16 6 W (or 8 W / 15 W) into lumi‑naires with energy‑efficient, long‑life LEDs. The conversion kit can be installed in any existing housing and can be connected to the existing power supply cable.operating mode: non‑maintained or maintained.

Article number Type of installation

Viewing distance

Luminous flux factor

Lamp/Wattage PZ 50 (.03)

Multi‑Digit (.04)

DALI (.07)

Rated operat‑ing time

Dimensions

671515.75X.y Ceiling (surface), Wall (surface) 25 m 32 % 1 x T16 (T5) 8 W • • ‑ 3 h L 344, B 144, H 78

671619.75X.y Ceiling (surface), Wall (surface) 25 m 32 % 1 x T16 (T5) 8 W with automatic self‑test function,

without feedback 3 h L 344, B 144, H 78

671517.75X.y Ceiling (surface), Wall (surface) 21 m ‑ 1 x T16 (T5) 8 W • • ‑ 3 h L 344, B 144, H 148

671620.75X.y Ceiling (surface), Wall (surface) 21 m ‑ 1 x T16 (T5) 8 W with automatic self‑test function,

without feedback 3 h L 344, B 144, H 148

For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration

Series: GSUN® 4

Type of protection: IP 54 for indoor use Protection class: II (I for .04) Viewing distance: 21 m, 25 m

For escape route identification or escape route illumination

Base: plastic (polycarbonate); diffuser: plastic (polycarbonate), opal, or refractor: transparent plastic (polycarbonate), prismatic; motif foils included; test button integrated in standard version.

Lamp included.

operating mode: Can either be connected in non‑maintained power mode (BS) or in maintained power mode (DS).

Ballast mains/emergency: EB

Available colour (X): 2 = white

Accessories | Wire guardBall impact proof in accordance with DIN 18032, Part 3 and DIN VDE 0710, Part 13

Wire guard and bracket: steel, white, powder‑coated. Wire guard mounted with screws, can be opened for luminaire maintenance.

Wire guard for wall luminaires981168.002 L 540, B 375, H 185

Mounting kit for chains/cable suspensions981583.002

Accessories | Pendant tubeSuspension tube Ø 10 mm, chrome, with canopy: white, powder‑coated and mounting material, with cable hanger, power supply cable for luminaire integrated in the tube.

Pendant tube90‑4164.002 LP 500 mm

Accessories | Wall extensionSteel bracket, white powder‑coated

Wall extension981485.002 L 374, B 147, H 75

Planning guide: Escape route illumination in accordance with EN 1838

E = 1 lx along the centre line

21 m/25 m

H

L B

50

250

15 110148,5

344

112,5 144

5x11

50

250

15 110148,5

344

112,5 144

5x11 h

d c b

a

Page 61: Emergency Lighting A1

59

EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES

For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration

Ceiling (surface), Wall (surface) (high hood) opal

Ceiling (surface), Wall (surface) (flat hood) transparent, prismatic

Article number Type of installation

Viewing distance

Luminous flux factor

Lamp/Wattage PZ 50 (.03)

Multi‑Digit (.04)

DALI (.07)

Rated operat‑ing time

Dimensions

671792.00X.y Wall (surface) 25 m ‑ 1 x LED 4,5 W • • ‑ 3 h L 344, B 144, H 78

671906.00X.y Wall (surface) 25 m ‑ 1 x LED 4,5 W • • ‑ 8 h L 344, B 144, H 78

671819.00X.y Ceiling (surface), Wall (surface) 21 m ‑ 1 x LED 4,5 W • • ‑ 3 h L 344, B 144, H 148

671907.00X.y Ceiling (surface), Wall (surface) 21 m ‑ 1 x LED 4,5 W • • ‑ 8 h L 344, B 144, H 148

Accessories | Wire guardBall impact proof in accordance with DIN 18032, Part 3 and DIN VDE 0710, Part 13

Wire guard and bracket: steel, white, powder‑coated. Wire guard mounted with screws, can be opened for luminaire maintenance.

Wire guard for wall luminaires981168.002 L 540, B 375, H 185

Mounting kit for chains/cable suspensions981583.002

Accessories | Pendant tubeSuspension tube Ø 10 mm, chrome, with canopy: white, powder‑coated and mounting material, with cable hanger, power supply cable for luminaire integrated in the tube.

Pendant tube90‑4164.002 LP 500 mm

Accessories | Wall extensionSteel bracket, white powder‑coated

Wall extension981485.002 L 374, B 147, H 75

Series: GSUN® 4 LED

Type of protection: IP 54 for indoor use Protection class: II (I for .04) Viewing distance: 21 m, 25 m

For escape route identification

Base: plastic (polycarbonate); diffuser: plastic (polycarbonate), opal, or refractor: transparent plastic (polycarbonate), prismatic, motif foil included, test button integrated in standard version.

LED included.

operating mode: Can either be connected in non‑maintained power mode (BS) or in maintained power mode (DS).

Ballast mains/emergency: EB

Available colour (X): 2 = white

50

250

15 110148,5

344

112,5 144

5x11

50

250

15 110148,5

344

112,5 144

5x11

H

L B

H

BL

21 m/25 m

Page 62: Emergency Lighting A1

60

EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES

Ceiling (surface), Wall (surface) Wall (surface)

LCS1 Type of protection: IP 40

- Extremely flat housing

- Reflector inside

- Lamp replacement without tools

- Easy to mount

- Large viewing distance

- Easy to install

Page 63: Emergency Lighting A1

61

EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES

For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration

Ceiling (surface), Wall (surface) Ceiling (surface), Wall (surface)

Spacing table 671608.752

Lamp luminous flux:

Mains: 400 lm, Emergency: 140 lm

The following values are indicated in m

h a b c d

2.5 5.9 2.2 8.7 3.2

3.0 6.2 2.2 9.0 2.9

3.5 6.4 2.2 9.1 2.6

4.0 6.5 2.1 8.8 2.2

Spacing table 671609.752

Lamp luminous flux:

Mains: 400 lm, Emergency: 140 lm

The following values are indicated in m

h a b c d

2.5 2.7 7.9 6.7 5.5

3.0 2.4 8.0 6.7 5.7

3.5 1.9 7.8 6.5 5.8

4.0 1.7 7.2 6.2 5.8

Replacement foils991112 Set of rescue symbols

2003, 2004 and 2005, viewing distance 35 m

Article number Type of installation

Viewing distance

Luminous flux factor

Lamp/Wattage PZ 50 (.03)

MultiDigit (.04)

DALI (.07)

Rated operat‑ing time

Dimensions

671608.75X.y Ceiling (surface), Wall (surface) 35 m 36 % 1 x T16 (T5) 8 W ‑ ‑ ‑ 1 h L 398, B 62, H 202

671609.75X.y Ceiling (surface), Wall (surface) 35 m 38 % 1 x T16 (T5) 8 W • • ‑ 3 h L 398, B 62, H 202

Series: LCS1

Type of protection: IP 40 Protection class: II Viewing distance: 35 m

For escape route identification or escape route illumination (escape route identification only for Wall (surface).)

Base and reflector: plastic (polycar‑bonate). Refractor: plastic (PMMA), transparent. Function monitoring and test button: standard. Lamp included.

Please note: Luminaire is only available for opera‑tion in non‑maintained power mode. It cannot be modified.

Motifs sets are to be ordered separately.

Ballast: EB

Available colour (X): 2 = white

Series: LCS3

Type of protection: IP 40 Protection class: II (I for .04) Viewing distance: 35 m

For escape route identification or escape route illumination (escape route identification only for Wall (surface).)

Base and reflector: plastic (polycarbo‑nate). Refractor: plastic (PMMA), trans‑parent. Three foils with escape legends included. Function monitoring and test button integrated in standard version. Lamp included. operating mode: Can either be connec‑ted in non‑maintained power mode (BS) or in maintained power mode (DS).

Ballast mains/emergency: EB

Available colour (X): 2 = white

Planning guide: Escape route illumination in accordance with EN 1838

E = 1 lx along the centre line

H

L B

174202

250371

398

8016

18

Ø5

35 m

H

L B

174202

250371

398

8016

18

Ø5

35 m

h

d c b

a

Page 64: Emergency Lighting A1

62

EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES

Ceiling (surface), Wall (surface) Wall (surface)

Varioplast I Type of protection: IP 54

- Ultraflat design

- IP 54 type of protection - dustproof and protected against water spray

- Installation-friendly construction: folding mounting plate with lampholder and ballast

- Shockproof verison

- Compact design

- Multi-purpose applications

Page 65: Emergency Lighting A1

63

EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES

For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration

Ceiling (surface), Wall (surface)

Spacing table 671111.75X

Lamp luminous flux:

Mains: 300 lm, Emergency: 108 lm

The following values are indicated in m

h a b c d

2.5 5.3 2.0 6.0 2.2

3.0 5.3 1.9 6.1 2.1

3.5 5.0 1.7 5.7 1.8

4.0 5.3 1.3 4.9 1.4

Article number Type of installation

Viewing distance

Luminous flux factor

Lamp/Wattage PZ 50 (.03)

MultiDigit (.04)

DALI (.07)

Rated operat‑ing time

Dimensions

671113.75X.y Wall (surface) 24 m ‑ 1 x T16 (T5) 6 W • • ‑ 3 h L 320, B 80, H 186

671111.75X.y Ceiling (surface), Wall (surface) ‑ 33 % 1 x T16 (T5) 6 W • • ‑ 3 h L 320, B 80, H 186

Series: Varioplast I

Type of protection: IP 54 for indoor use Protection class: I Viewing distance: 24 m

For escape route identification (only in case of Wall (recessed)) or escape route illumination

Base: plastic (polycarbonate); refractor: plastic (polycarbonate), transparent, prismatic inside, 3 foils for escape route identification included.

Lamp included.

operating mode: Can either be connected in non‑maintained power mode (BS) or in maintained power mode (DS).

Ballast mains/emergency: EB

Available colours (X): 2 = white, 3 = black

Accessories | Wire guardBall impact proof in accordance with DIN 18032, Part 3 and DIN VDE 0710, Part 13

Wire guard and bracket: steel, white, powder‑coated. Wire guard mounted with screws, can be opened for luminaire maintenance.

Wire guard for wall luminaires981168.002 L 540, B 375, H 185

Accessories | Set of screws with special anti-theft key90‑4013.002 white90‑4013.003 black

Accessories | Wire guard, varnished22125.002 L 314, B 180, H 49 white22125.003 L 314, B 180, H 49 black

Planning guide: Escape route illumination in accordance with EN 1838

E = 1 lx along the centre line

24 m

H

B

L

6

27148

16

115

288320

15430

116 186

8016

5x8

h

d c b

a

Page 66: Emergency Lighting A1

64

EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES

Ceiling (surface), Wall (surface)

Space Type of protection: IP 40

- Shockproof housing in flat, elegant design

- Installation-friendly construction

- Easy lamp replacement

- Theft protection: quick mount adaptor with lock system

- Reflector inside

- Functional design

Page 67: Emergency Lighting A1

65

EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES

For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration

Ceiling (surface), Wall (surface) Ceiling (surface), Wall (surface)

Spacing table 67923.750

Lamp luminous flux:

Mains: 450 lm, Emergency: 225 lm

The following values are indicated in m

h a b c d

2.5 6.3 2.3 5.7 2.2

3.0 6.1 2.4 5.8 2.3

3.5 5.6 2.0 5.9 2.3

4.0 5.7 1.7 5.8 1.9

Spacing table 67924.750

Lamp luminous flux:

Mains: 300 lm, Emergency: 150 lm

The following values are indicated in m

h a b c d

2.5 6.2 2.3 5.6 2.1

3.0 6.1 2.1 5.3 2.2

3.5 5.8 2.0 5.7 2.1

4.0 5.2 1.6 6.0 1.7

Article number Type of installation

Viewing distance

Luminous flux factor

Lamp/Wattage PZ 50 (.03)

MultiDigit (.04)

DALI (.07)

Rated operat‑ing time

Dimensions

67924.75X.y Ceiling (surface), Wall (surface) 20 m 54 % 1 x T16 (T5) 6 W ‑ ‑ ‑ 3 h L 280, B 130, H 53

67923.75X.y Ceiling (surface), Wall (surface) 25 m 58 % 1 x T16 (T5) 8 W ‑ ‑ ‑ 3 h L 374, B 164, H 70

Series: Space

Type of protection: IP 40 Protection class: II Viewing distance: 20 m, 25 m

For escape route identification (only in case of wall installation) or escape route illumination

Base: plastic, grey. Refractor: plastic (polycarbonate), transparent, prismatic. Patented quick mount adaptor. 3 plastic foils and lamp included.

operating mode: Can either be connected in non‑maintained power mode (BS) or in maintained power mode (DS).

Ballast mains/emergency: EB

Available colour (X): 9 = grey

Accessories | Wire guardBall impact proof in accordance with DIN 18032, Part 3 and DIN VDE 0710, Part 13

Wire guard and bracket: steel, white, powder‑coated. Wire guard mounted with screws, can be opened for luminaire maintenance.

Wire guard for wall luminaires981167.002 L 380, B 295, H 185 for 6 W981168.002 L 540, B 375, H 185 for 8 W

Planning guide: Escape route illumination in accordance with EN 1838

E = 1 lx along the centre line

20 m/25 m

L

H

B

L

H

B

40104130

170

254280

65

5x10

4060

134164

170240

344374

65

5x10

h

d c b

a

Page 68: Emergency Lighting A1

66

EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES

Ceiling (surface), Wall (surface)

Universum Type of protection: IP 40

- Shockproof housing in flat, elegant design

- Installation-friendly construction

- Easy lamp replacement

- Theft protection: quick mount adaptor with lock system

- Reflector inside

- Functional design

Page 69: Emergency Lighting A1

67

EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES

For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration

Ceiling (surface), Wall (surface)

Spacing table 671116.750

Lamp luminous flux:

Mains: 450 lm, Emergency: 167 lm

The following values are indicated in m

h a b c d

2.5 6.4 2.3 6.0 2.2

3.0 6.6 2.3 6.0 2.3

3.5 6.4 2.0 6.0 2.2

4.0 6.4 1.6 6.2 1.8

Article number Type of installation

Viewing distance

Luminous flux factor

Lamp/Wattage PZ 50 (.03)

MultiDigit (.04)

DALI (.07)

Rated operat‑ing time

Dimensions

671116.75X.y Ceiling (surface), Wall (surface) 20 m 37 % 1 x T16 (T5) 8 W ‑ ‑ ‑ 3 h L 360, B 115, H 52

Series: Universum

Type of protection: IP 40 Protection class: II Viewing distance: 20 m

For escape route identification or escape route illumination

Base: plastic, white. Refractor: plastic (polycarbonate), transparent, prismatic. Patented quick mount adaptor. 3 foils and lamp included.

operating mode: Can either be connected in non‑maintained power mode (BS) or in maintained power mode (DS).

Ballast mains/emergency: EB

Available colour (X): 9 = grey

Accessories | Wire guardBall impact proof in accordance with DIN 18032, Part 3 and DIN VDE 0710, Part 13

Wire guard and bracket: steel, white, powder‑coated. Wire guard mounted with screws, can be opened for luminaire maintenance.

Wire guard for wall luminaires981168.002 L 540, B 375, H 185

Accessories | Recessed housing with cover frameRecess dimensions: 410 x 145 mm, depth 52 mmRecessed housing with cover frame67006.009 L 415, B 165, H 44, HE 52

Accessories | Escape route identificationfor surface ceiling mounting or recessed ceiling mounting (recessed ceiling mounting in connection with 67006.009).

Display dimensions: L 310, B 155 mm, viewing distance : 30 m

Accessories | Escape route identification67004.009 Escape route right/left67005.009 Emergency exit

Planning guide: Escape route illumination in accordance with EN 1838

E = 1 lx along the centre line

20 m

L

H

B

40104115

170

347360

65

5x10

h

d c b

a

Page 70: Emergency Lighting A1

68

EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES

Ceiling (recessed)

Turia Type of protection: IP 30

- Wide luminaire spacing for escape route illumination

- Energy efficient (consumption approx. 90% less than 13 W fluorescent lamp technology)

- Top quality LED technology

- Specially calculated thermal management

- Very low maintenance costs

- LED service life: approx. 50,000 hours

- Easy to install

- Compact design

- Inconspicuous design

- The single-battery module and storage battery can be inserted and removed through the ceiling opening

Page 71: Emergency Lighting A1

69

EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES

For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration

Ceiling (recessed)

Spacing table 671920.00X und 671921.00X

Lamp luminous flux:

Mains: 148 lm, Emergency: 148 lm

The following values are indicated in m

h a b c d

2.5 7.3 3.0 7.3 3.0

3.0 8.2 3.4 8.2 3.4

3.5 8.9 3.6 8.9 3.6

4.0 9.5 3.7 9.5 3.7

Article number Type of installation

operating mode BS / DS

Luminous flux factor

Lamp/Wattage PZ 50 (.03)

MultiDigit (.04)

DALI (.07)

Rated operat‑ing time

Dimensions

671920.00X.y Ceiling (recessed) BS 100 % 1 x LED 2 W ‑ ‑ • 3 h D 50, H 2 DA 42, HE 45

671921.00X.y Ceiling (recessed) BS / DS 100 % 1 x LED 2 W ‑ ‑ • 3 h D 50, H 2 DA 42, HE 45

Step 1 Step 2

Step 3 Step 4

Series: Turia

Type of protection: IP 30 Protection class: II Ceiling thickness: 15‑35 mm

For escape route illumination

Housing: die‑cast aluminium. Bezel ring: plastic, white. Module and battery in separate ballast box with connecting cable. Automatic self test in all standard versions.

LED included.

operating mode: Can either be connected in non‑maintained power mode (BS) or in maintained power mode (DS).

Ballast mains/emergency: EB

Available colour (X): 2 = white

Planning guide: Escape route illumination in accordance with EN 1838

E = 1 lx along the centre line

HDAD

HE

Ø50 Ø42

h

d c b

a

Page 72: Emergency Lighting A1

70

+

EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES

Edo 1 Installation in existing luminiares

Edo 2 Installation in metal ceilings

Edo 4 Edo 5

Example

Edo Type of protection: IP 20

- Wide luminaire spacing for escape route illumination

- Energy efficient (consumption approx. 80% less than 13 W fluorescent lamp technology)

- Top quality LED technology

- Specially calculated thermal management

- Very low maintenance costs

- LED service life: approx. 50,000 hours

- Easy to install

- Compact design

- Inconspicuous design

+

=

Page 73: Emergency Lighting A1

71

EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES

For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration

Edo 1 Edo 2 Edo 4 Edo 5

Accessories | Fixing bracket for Edo 1Bracket for fixing Edo 1 into recessed luminiares such as downlights or louvre luminaires. Bracket is to be installed in existing reflector or louvre.

Fixing bracket for Edo 1981778.000 L 25, B 19, H 22

Spacing table 671931.004

Lamp luminous flux:

Mains: 109 lm, Emergency: 109 lm

The following values are indicated in m

h a b c d

2.5 7.7 3.0 7.7 3.0

3.0 8.5 3.2 8.5 3.2

3.5 8.9 3.2 8.9 3.2

4.0 9.1 3.2 9.1 3.2

Article number Type of installation

operating mode BS / DS

Type Lamp/Wattage PZ 50 (.03)

MultiDigit (.04)

DALI (.07)

Rated operat‑ing time

Dimensions

671931.00X.y Retrofitting kit BS Edo 1 1 x LED 2 W ‑ ‑ • 3 h D 22, H 8, DA 10.5, HE 15

671932.00X.y Retrofitting kit BS / DS Edo 1 1 x LED 2 W ‑ ‑ • 3 h D 22, H 8, DA 10.5, HE 15

671933.00X.y Installation in metal ceilings BS Edo 2 1 x LED 2 W ‑ ‑ • 3 h D 27, H 1, DA 22, HE 23

671934.00X.y Installation in metal ceilings BS / DS Edo 2 1 x LED 2 W ‑ ‑ • 3 h D 27, H 1, DA 22, HE 23

671927.00X.y Ceiling (recessed) BS Edo 4 1 x LED 2 W ‑ ‑ • 3 h D 50, H 3, DA 40, HE 45

671928.00X.y Ceiling (recessed) BS / DS Edo 4 1 x LED 2 W ‑ ‑ • 3 h D 50, H 3, DA 40, HE 45

671929.00X.y Ceiling (recessed) BS Edo 5 1 x LED 2 W ‑ ‑ • 3 h L 50, B 50, H 3, DA 40, HE 45

671930.00X.y Ceiling (recessed) BS / DS Edo 5 1 x LED 2 W ‑ ‑ • 3 h L 50, B 50, H 3, DA 40, HE 45

Table applies to all Edo series luminaires

Series: Edo

Type of protection: IP 30 Protection class: II Ceiling thickness: 1‑8 mm (Edo 1 and Edo 2) Ceiling thickness: 15‑35 mm (Edo 4 and Edo 5)

For escape route illumination

Housing: die‑cast aluminium, bezel ring: plastic, white, (only Edo 4 + 5), separate ballast box with connection cable. Automatic self test in all standard versions.

LED included.

operating mode: Can be ordered either for non‑maintained (BS) or maintained (DS).

Ballast mains/emergency: EB

Luminous flux factor 100%

Available colours (X): 2 = white (Edo 4 and Edo 5), 4 = aluminium (Edo 1 and Edo 2)

Planning guide: Escape route illumination in accordance with EN 1838

E = 1 lx along the centre line

H

DA

HE

D

DA

D

H

HE

HDAD

HE

HBAB

HE

LA L

Ø50 Ø40 Ø50 Ø40

Edo 2

Edo 1

h

d c b

a

Page 74: Emergency Lighting A1

72

EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES

Ceiling (surface) Ceiling (recessed)

Lucio Type of protection: IP 40

- Wide luminaire spacing for escape route illumination

- Energy efficient (consumption approx. 90% less than 13 W fluorescent lamp technology)

- Top quality LED technology

- Specially calculated thermal management

- Very low maintenance costs

- LED service life: approx. 50,000 hours

- Compact design

- Easy to install

- Wide range of applications thanks to either surface or recessed ceiling installation

Page 75: Emergency Lighting A1

73

EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES

For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration

Ceiling (surface) Ceiling (recessed)

Spacing table 671917.002

Lamp luminous flux:

Mains: 82 lm, Emergency: 82 lm

The following values are indicated in m

h a b c d

2.5 5.3 2.1 5.3 2.1

3.0 5.9 2.1 5.9 2.1

3.5 6.3 1.9 6.3 1.9

4.0 6.4 1.5 6.4 1.5

Spacing table 671918.002

Lamp luminous flux:

Mains: 100 lm, Emergency: 100 lm

The following values are indicated in m

h a b c d

2.5 7.1 3.0 4.3 1.6

3.0 8.0 3.3 4.5 1.6

3.5 8.7 3.6 4.6 1.7

4.0 9.3 3.8 4.8 1.7

Article number Type of installation

Type Luminous flux factor

Lamp/Wattage PZ 50 (.03)

MultiDigit (.04)

DALI (.07)

Rated operat‑ing time

Dimensions

671917.00X.y Ceiling (surface), Ceiling (recessed)

without lenses 100% 1 x LED 3 W ‑ ‑ • 3 h Surface installation:

D 120, H 45

Recessed installation: D 120, H 3, DA 105, HE 42

671918.00X.y Ceiling (surface), Ceiling (recessed)

with lenses 100% 1 x LED 3 W ‑ ‑ • 3 h

Series: Lucio

Type of protection: IP 40 Protection class: II Ceiling thickness: 5‑25 mm

For escape route illumination

Housing: plastic. Accessories for recessed and surface mounting on the ceiling are included. Automatic self test in all standard versions.

LED included.

operating mode: non‑maintained power mode (BS)

Ballast: EB

2 lenses included in article number 671918.00X.y.

Available colour (X): 2 = white

Planning guide: Escape route illumination in accordance with EN 1838

E = 1 lx along the centre line

H

D

104

HDAD

HE

51

25(78)

Ø4,2

Ø16

Ø12059

73,5Ø4,2

Ø120 Ø105

h

d c b

a

Page 76: Emergency Lighting A1

74

EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES

Ceiling (recessed), squareCeiling (surface) Ceiling (recessed), round

Centryxx Type of protection: IP 40

- Wide luminaire spacing for escape route illumination

- Design matches modern architectural styles

- Energy efficient (consumption approx. 90% less than 13 W fluorescent lamp technology)

- Top quality LED technology

- Specially calculated thermal management

- Very low maintenance costs

- LED service life: approx. 50,000 hours

- Easy to install

Page 77: Emergency Lighting A1

75

EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES

For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration

Ceiling (recessed), square Ceiling (recessed), roundCeiling (surface)

Spacing table 671840.002

Lamp luminous flux:

Mains: 180 lm, Emergency: 180 lm

The following values are indicated in m

h a b c d

2.5 3.4 0.9 12.6 5.6

3.0 3.0 0.8 14.2 6.4

3.5 2.6 0.7 16.1 7.1

4.0 2.4 0.0 10.5 0.0

Table applies to all Centryxx series luminaires

Article number Type of installation

Type Luminous flux factor

Lamp/Wattage PZ 50 (.03)

MultiDigit (.04)

DALI (.07)

Rated operat‑ing time

Dimensions

671840.00X.y Ceiling (surface) square 100 % 1 x LED 3 W

with automatic self‑test function, without feedback

3 h L 180, B 180, H 27

671838.00X.y Ceiling (recessed) square 100 % 1 x LED 3 W 3 h L 220, B 220, H 3, DA 185, HE 73

671836.00X.y Ceiling (recessed) round 100 % 1 x LED 3 W 3 h D 200, H 3 DA 185, HE 73

Series: Centryxx

Type of protection: IP 20 (Ceiling (surface)), IP 40 (Ceiling (recessed)) Protection class: I

For escape route illumination

Housing: die‑cast aluminium, powder‑coated; plastic diffuser for ideal light distribution on escape route. Automatic self test in all standard versions.

LED included.

operating mode: non‑maintained power mode (BS)

Ballast mains/emergency: EB

Available colour (X): 2 = white

Planning guide: Escape route illumination in accordance with EN 1838

E = 1 lx along the centre line

HDAL

HE

B

HDAD

HE

B

L H

220 Ø185

220

Ø200 Ø185

Ø5

180

90180

90

51

Ø5

h

d c b

a

Page 78: Emergency Lighting A1

76

EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES

Ceiling (recessed)

Energo TC 175 Type of protection: IP 23

- Design continuity to the general lighting programme. We offer an extensive range of emergency lighting and general lighting systems. As such, we can provide our customers with integrated solutions for all areas of application, depending on their construction projects.

- Housing made of top quality die-cast aluminium

- Wide luminaire spacing for escape route illumination

- Modern design

- Bezel ring made of die-cast aluminium

- Infinitely adjustable spring fastening system

- EBs in separate ballast box

- Modular recessed luminaire with small recessed depth

- Easy to install

- For ceiling thicknesses of 1-40 mm

Page 79: Emergency Lighting A1

77

EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES

For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration

Ceiling (recessed)

Moulded housing981656.000 Moulded housing L 500, B 250, H 160 mm

Spacing table 671873.92X und 671875.92X

Lamp luminous flux:

Mains: 900 lm, Emergency: 162 lm

The following values are indicated in m

h a b c d

2.5 7.7 2.8 7.7 2.8

3.0 8.1 2.9 8.1 2.9

3.5 8.4 2.8 8.4 2.8

4.0 8.3 2.7 8.3 2.7

Spacing table 671874.96X und 671876.96X

Lamp luminous flux:

Mains: 1200 lm, Emergency: 180 lm

The following values are indicated in m

h a b c d

2.5 7.5 2.9 7.5 2.9

3.0 8.1 3.1 8.1 3.1

3.5 8.5 3.0 8.5 3.0

4.0 8.7 3.0 8.7 3.0

Article number Type of installation

Lamps Mains/Emergency

Luminous flux factor

Lamp/Wattage PZ 50 (.03)

MultiDigit (.04)

DALI (.07)

Rated operat‑ing time

Dimensions

671873.92X.y Ceiling (recessed) 1 / 1 18 % 1 x TC‑DEL 13 W • • ‑ 3 h D 188, H 4 DA 175, HE 100

671875.92X.y Ceiling (recessed) 2 / 1 18 % 2 x TC‑DEL 13 W • • ‑ 3 h D 188, H 4 DA 175, HE 100

671874.96X.y Ceiling (recessed) 1 / 1 15 % 1 x TC‑DEL 18 W • • ‑ 3 h D 188, H 4 DA 175, HE 100

671876.96X.y Ceiling (recessed) 2 / 1 15 % 2 x TC‑DEL 18 W • • ‑ 3 h D 188, H 4 DA 175, HE 100

Series: Energo TC 175

Type of protection: IP 23 with bezel ring without safety glass, IP 44 with bezel ring including safety glass Protection class: I Ceiling thickness: 1‑40 mm

For escape route illumination

Modular design: A bezel ring must always be ordered for each basic luminaire!

Recess and bezel ring: die‑cast aluminium, bezel ring with bayonet fixing; bracket: galvanised sheet steel; reflector: aluminium, highly polished anodised finish; installation in ceiling with spring system. EB in separate ballast box with connection cable (L 400 mm) in flexible hose; 5‑pole double terminal for through‑wiring.

operating mode: Can either be connected in non‑maintained power mode (BS) or in maintained power mode (DS).

Ballast mains/emergency: EB

Available colour (X) Basic luminaire: 4 = silver metallic

Panel mounting frame98102.002/176 Panel mounting frame Dimensions 285 x 285 mm

Bezel rings with safety glass, D 194 mm, H 9 mm 981653.002 Safety glass, transparent981653.004 Safety glass, transparent

Bezel rings without safety glass, D 194 mm, H 9 mm981653.102981653.104

Planning guide: Escape route illumination in accordance with EN 1838

E = 1 lx along the centre line

Ø188 Ø175

HDAD

HE

h

d c b

a

Page 80: Emergency Lighting A1

78

EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES

Ceiling (recessed)

Energo TC 210 Type of protection: IP 23

- Design continuity to the general lighting programme. We offer an extensive range of emergency lighting and general lighting systems. As such, we can provide our customers with integrated solutions for all areas of application, depending on their construction projects.

- Housing made of top quality die-cast aluminium

- Wide luminaire spacing for escape route illumination

- Modern design

- Bezel ring made of die-cast aluminium

- Infinitely adjustable spring fastening system

- EBs in separate ballast box

- Modular recessed luminaire with small recessed depth

- Easy to install

- For ceiling thicknesses of 1-40 mm

Page 81: Emergency Lighting A1

79

EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES

For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration

Ceiling (recessed)

Moulded housing981662.000 Moulded housing L 450, B 300, H 200 mm

Spacing table 671881.83X und 671882.83X

Lamp luminous flux:

Mains: 1800 lm, Emergency: 252 lm

The following values are indicated in m

h a b c d

2.5 9.4 3.8 9.4 3.8

3.0 10.3 4.1 10.3 4.1

3.5 11.0 4.1 11.0 4.1

4.0 11.5 4.1 11.5 4.1

Article number Type of installation

Lamps Mains/Emergency

Luminous flux factor

Lamp/Wattage PZ 50 (.03)

MultiDigit (.04)

DALI (.07)

Rated operat‑ing time

Dimensions

671881.83X.y Ceiling (recessed) 1 / 1 14 % 1 x TC‑TEL 32 W • • ‑ 3 h D 220, H 4 DA 210, HE 120

671882.83X.y Ceiling (recessed) 2 / 1 14 % 2 x TC‑TEL 32 W • • ‑ 3 h D 220, H 4 DA 210, HE 120

Series: Energo TC 210

Type of protection: IP 23 with bezel ring without safety glass, IP 44 with bezel ring including safety glass Protection class: I Ceiling thickness: 1‑40 mm

For escape route illumination

Modular design: A bezel ring must always be ordered for each basic luminaire!

Recessed and bezel ring: die‑cast aluminium; bezel ring with bayonet fixing; bracket: galvanised sheet steel; reflector: alumi‑nium, highly polished anodised finish; installation in ceiling with spring system. EB in separate ballast box wit connection cable L 400 mm in flexible hose, 5‑pole double terminal for through‑wiring.

operating mode: Can either be connected in non‑maintained power mode (BS) or in maintained power mode (DS).

Ballast mains/emergency: EB

Available colour (X) Basic luminaire: 4 = silver metallic

Panel mounting frame98102.002/215 Panel mounting frame Dimensions 285 x 285 mm

Bezel rings with decorative attachment, D 250 mm, H 38 mm 981660.002 Decorative glass, transparent981660.004 Decorative glass, transparent

Bezel rings with safety glass, D 227 mm, H 9 mm 981659.002 Safety glass, transparent981659.004 Safety glass, transparent

Planning guide: Escape route illumination in accordance with EN 1838

E = 1 lx along the centre line

Ø220 Ø210

HDAD

HE

h

d c b

a

Page 82: Emergency Lighting A1

80

EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES

Ceiling (surface)

Andho TC Type of protection: IP 23

- Design continuity to the general lighting programme. We offer an extensive range of emergency lighting and general lighting systems. As such, we can provide our customers with integrated solutions for all areas of application, depending on their construction projects.

- Design matches modern architectural styles

- Housing made of top quality die-cast aluminium

- Top quality reflector made of aluminium, highly polished anodised finish

Page 83: Emergency Lighting A1

81

EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES

For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration

Ceiling (surface)

Spacing table 671891.84X und 671892.84X

Lamp luminous flux:

Mains: 1200 lm, Emergency: 168 lm

The following values are indicated in m

h a b c d

2.5 7.7 3.0 7.7 3.0

3.0 8.5 3.3 8.5 3.3

3.5 9.0 3.3 9.0 3.3

4.0 9.3 3.3 9.3 3.3

Article number Type of installation

Lamps Mains/Emergency

Luminous flux factor

Lamp/Wattage PZ 50 (.03)

MultiDigit (.04)

DALI (.07)

Rated operat‑ing time

Dimensions

671891.84X.y Ceiling (surface) 1 / 1 14 % 1 x TC‑TEL 18 W • • ‑ 3 h D 230, H 278

671892.84X.y Ceiling (surface) 2 / 1 14 % 2 x TC‑TEL 18 W • • ‑ 3 h D 230, H 278

Series: Andho TC

Type of protection: IP 23 Protection class: I

For escape route illumination

Housing: aluminium extrusion profile, powder‑coated; bezel ring and ceiling base: die‑cast aluminium, powder‑coated, with bayonet fixing; reflector: aluminium, highly polished anodised finish; EB incorporated, 5 pole double terminal for through‑wiring.

operating mode: Can either be connected in non‑maintained power mode (BS) or in maintained power mode (DS).

Ballast mains/emergency: EB

Available colours (X): 2 = white, 4 = silver metallic

Planning guide: Escape route illumination in accordance with EN 1838

E = 1 lx along the centre line

H

D

178

45178

Ø230

Ø7

h

d c b

a

Page 84: Emergency Lighting A1

82

EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES

Ceiling (surface)

Andho TC IP 65 Type of protection: IP 65

- Design continuity to the general lighting programme. We offer an extensive range of emergency lighting and general lighting systems. As such, we can provide our customers with integrated solutions for all areas of application, depending on their construction projects.

- Design matches modern architectural styles

- Housing made of top quality die-cast aluminium

- Top quality reflector made of aluminium, highly polished anodised finish

Page 85: Emergency Lighting A1

83

EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES

For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration

Ceiling (surface)

Spacing table 671893.84X und 671894.84X

Lamp luminous flux:

Mains: 1200 lm, Emergency: 168 lm

The following values are indicated in m

h a b c d

2.5 7.6 2.9 7.6 2.9

3.0 8.2 3.2 8.2 3.2

3.5 8.7 3.2 8.7 3.2

4.0 9.0 3.2 9.0 3.2

Article number Type of installation

Lamps Mains/Emergency

Luminous flux factor

Lamp/Wattage PZ 50 (.03)

MultiDigit (.04)

DALI (.07)

Rated operat‑ing time

Dimensions

671893.84X.y Ceiling (surface) 1 / 1 14 % 1 x TC‑TEL 18 W • • ‑ 3 h D 230, H 290

671894.84X.y Ceiling (surface) 2 / 1 14 % 2 x TC‑TEL 18 W • • ‑ 3 h D 230, H 290

Series: Andho TC IP 65

Type of protection: IP 65 for indoor use Protection class: I

For escape route illumination

Housing: aluminium extrusion profile, powder‑coated; ceiling base: die‑cast aluminium, powder‑coated, with bayonet fixing; bezel ring: powder‑coated die‑cast aluminium, screwed on the luminaire; safety glass, transparent; reflector: aluminium, highly polished anodised finish; EB incorporated, 5 pole double terminal for through‑wiring.

operating mode: Can either be connected in non‑maintained power mode (BS) or in maintained power mode (DS).

Ballast mains/emergency: EB

Available colours (X): 2 = white, 4 = silver metallic

Planning guide: Escape route illumination in accordance with EN 1838

E = 1 lx along the centre line

H

D

178

45178

Ø230

Ø7

h

d c b

a

Page 86: Emergency Lighting A1

84

EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES

Ceiling (recessed)

Arelo® Type of protection: IP 20

- Design continuity to the general lighting programme. We offer an extensive range of emergency lighting and general lighting systems. As such, we can provide our customers with integrated solutions for all areas of application, depending on their construction projects.

- Recessed ring made of die-cast aluminium

- Top quality reflector made of aluminium, highly polished anodised finish

- Wide beam light distribution

- All versions with EB in separate ballast box

- Simple spring system for installation without tools

Page 87: Emergency Lighting A1

85

EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES

For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration

Ceiling (recessed)

Spacing table 671857.96X und 671859.96X

Lamp luminous flux:

Mains: 1200 lm, Emergency: 180 lm

The following values are indicated in m

h a b c d

2.5 7.6 3.3 8.3 3.5

3.0 8.5 3.4 9.2 3.8

3.5 9.4 3.1 10.0 3.8

4.0 9.5 3.0 10.7 3.0

Spacing table 671858.95X und 671860.95X

Lamp luminous flux:

Mains: 1800 lm, Emergency: 216 lm

The following values are indicated in m

h a b c d

2.5 7.5 3.0 8.1 3.3

3.0 8.2 2.8 8.9 3.3

3.5 8.5 2.5 9.4 2.5

4.0 8.1 2.2 9.0 2.6

Article number Type of installation

Lamps Mains/Emergency

Luminous flux factor

Lamp/Wattage PZ 50 (.03)

MultiDigit (.04)

DALI (.07)

Rated operat‑ing time

Dimensions

671857.96X.y Ceiling (recessed) 1 / 1 15 % 1 x TC‑DEL 18 W • • ‑ 3 h D 218, H 3 DA 200, HE 106

671859.96X.y Ceiling (recessed) 2 / 1 15 % 2 x TC‑DEL 18 W • • ‑ 3 h D 218, H 3 DA 200, HE 106

671858.95X.y Ceiling (recessed) 1 / 1 12 % 1 x TC‑DEL 26 W • • ‑ 3 h D 218, H 3 DA 200, HE 106

671860.95X.y Ceiling (recessed) 2 / 1 12 % 2 x TC‑DEL 26 W • • ‑ 3 h D 218, H 3 DA 200, HE 106

Series: Arelo®

Type of protection: IP 20 Protection class: I Ceiling thickness: 1‑25 mm

For escape route illumination

Recess ring: die‑cast aluminium, powder‑coated; bracket: galvanised sheet steel; reflector: aluminium, highly polished ano‑dised finish; separate ballast box, length of cable between luminaire and ballast box: 400 mm, suitable for through‑wiring

operating mode: Can either be connected in non‑maintained power mode (BS) or in maintained power mode (DS).

Ballast mains/emergency: EB

Available colour (X): 2 = white

Cover screens with spring fastening IP 43981734.000 Safety glass, transparent

Planning guide: Escape route illumination in accordance with EN 1838

E = 1 lx along the centre line

HE

DAD

H

Ø218 Ø200

h

d c b

a

Page 88: Emergency Lighting A1

86

EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES

Mondana Type of protection: IP 65

- Design continuity to the general lighting programme. We offer an extensive range of emergency lighting and general lighting systems. As such, we can provide our customers with integrated solutions for all areas of application, depending on their construction projects.

- Design matches modern architectural styles

- Diffuser: glass or PE sintered glass (polyethylene), shockproof

- IP 65 provides safe protection against humidity - dust and insects cannot penetrate the luminaire

- Gore™ diaphragm valve for pressure equalisation and prevention of condensation

- Easy to install

- Wide range of applications thanks to various types of installation

- Lamp replacement without tools

Surface installation (wall, ceiling) D 500 and D 550

Recessed installation (wall and ceiling) DA 625

Semi‑recessed installation (wall, ceiling) DA 390

Page 89: Emergency Lighting A1

87

EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES

For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration

Accessories | Moulded housing

Moulded housing 981631.002 for Mondana D 500981631.002 for Mondana D 550

Spacing table 671779.86X

Lamp luminous flux:

Mains: 2800 lm, Emergency: 392 lm

The following values are indicated in m

h a b c d

2.5 6.1 2.8 6.0 2.8

3.0 6.3 3.0 6.1 3.0

3.5 8.3 2.9 8.3 2.9

4.0 8.5 2.8 8.5 2.8

Spacing table 671777.86X

Lamp luminous flux:

Mains: 2800 lm, Emergency: 392 lm

The following values are indicated in m

h a b c d

2.5 6.6 2.4 6.6 2.4

3.0 6.8 2.3 6.8 2.3

3.5 6.9 2.1 6.9 2.1

4.0 6.8 1.9 6.8 1.9

Spacing table 671778.00X

Lamp luminous flux:

Mains: 2800 lm, Emergency: 392 lm

The following values are indicated in m

h a b c d

2.5 5.8 2.7 5.6 2.7

3.0 7.6 2.8 7.6 2.8

3.5 7.9 2.7 7.9 2.7

4.0 8.0 2.6 8.0 2.6

Spacing table 671802.00X

Lamp luminous flux:

Mains: 2800 lm, Emergency: 392 lm

The following values are indicated in m

h a b c d

2.5 5.8 2.7 5.6 2.7

3.0 7.6 2.8 7.6 2.8

3.5 7.9 2.7 7.9 2.7

4.0 8.0 2.6 8.0 2.6

Spacing table 671803.00X

Lamp luminous flux:

Mains: 2800 lm, Emergency: 392 lm

The following values are indicated in m

h a b c d

2.5 6.6 2.4 6.6 2.4

3.0 6.8 2.3 6.8 2.3

3.5 6.9 2.1 6.9 2.1

4.0 6.8 1.9 6.8 1.9

Article number Type of installation

Type Luminous flux factor

Lamp/Wattage PZ 50 (.03)

MultiDigit (.04)

DALI (.07)

Rated operat‑ing time

Dimensions

671777.86X.y Wall (surface), Ceiling (surface) Glass 14 % 1 x TC‑F 36 W • • ‑ 3 h D 500, H 128

671778.86X.y Wall (surface), Ceiling (surface) PE 14 % 1 x TC‑F 36 W • • ‑ 3 h D 550, H 135

671803.86X.y Semi‑recessed instal‑lation (wall, ceiling) Glass 14 % 1 x TC‑F 36 W • • ‑ 3 h D 500, H 78

DA 390, HE 100

671802.86X.y Semi‑recessed instal‑lation (wall, ceiling) PE 14 % 1 x TC‑F 36 W • • ‑ 3 h D 550, H 85

DA 390, HE 100

671779.86X.y Wall (recessed), Ceiling (recessed) PE 14 % 1 x TC‑F 36 W • • ‑ 3 h D 650, H 2

DA 625, HE 140

Series: Mondana

Type of protection: IP 65 for indoor use Protection class: I Ceiling thickness: 10‑30 mm

For escape route illumination

Base: plastic (polycarbonate), microstructure coating; diffuser: plastic (polyethylene) or mouth‑blown opal glass, satin finish. Diffuser fastening: screwneck; housing for semi‑recessed installation in walls and ceilings: powder‑coated aluminium. Standard Gore™ Protective Vents diaphragm valve for reduction of condensation.

operating mode: Can either be connected in non‑maintained power mode (BS) or in maintained power mode (DS).

Ballast mains/emergency: EB

Available colour (X): 2 = white

Planning guide: Escape route illumination in accordance with EN 1838

E = 1 lx along the centre line

Surface installation (wall, ceiling) D 500 and D 550

Recessed installation (wall and ceiling) DA 625

Semi‑recessed installation (wall, ceiling) DA 390

D H

D H

HE

DA

D H

HE

DA

Ø625Ø390

140

5242,5

Ø380

Ø5,5

7065

h

d c b

a

Page 90: Emergency Lighting A1

88

EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES

Ceiling (surface), Wall (surface)

8hfor

accomodation facilities, nursing homes and

multi-storey buildings

(only in Germany)

Flat Polymero® Type of protection: IP 40

- Design continuity to the general lighting programme. We offer an extensive range of emergency lighting and general lighting systems. As such, we can provide our customers with integrated solutions for all areas of application, depending on their construction projects.

- Design matches modern architectural styles

- Compact design

- Extremely high Light Output Ratio of up to 81%

- Easy to install

- Low maintenance costs

- Wide range of applications thanks to various types of installation

Page 91: Emergency Lighting A1

89

EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES

For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration

Ceiling (surface), Wall (surface) D 460 Ceiling (surface), Wall (surface) D 515 Ceiling (surface), Wall (surface) D 620

Spacing table 671587.962

Lamp luminous flux:

Mains: 1200 lm, Emergency: 180 lm

The following values are indicated in m

h a b c d

2.5 5.7 2.2 5.7 2.2

3.0 5.9 2.2 5.9 2.2

3.5 6.1 2.0 6.1 2.0

4.0 6.2 1.6 6.2 1.6

Spacing table 671585.862

Lamp luminous flux:

Mains: 2800 lm, Emergency: 392 lm

The following values are indicated in m

h a b c d

2.5 7.6 3.2 7.6 3.2

3.0 8.4 3.4 8.4 3.4

3.5 8.8 3.4 8.8 3.4

4.0 8.9 3.4 8.9 3.4

Spacing table 671911.95X

Lamp luminous flux:

Mains: 1800 lm, Emergency: 1800 lm

The following values are indicated in m

h a b c d

2.5 13.0 5.2 13.0 5.2

3.0 13.1 5.6 13.1 5.6

3.5 14.3 5.8 14.3 5.8

4.0 15.1 6.1 15.1 6.1

Spacing table 671700.34X

Lamp luminous flux:

Mains: 1200 lm, Emergency: 1200 lm

The following values are indicated in m

h a b c d

2.5 10.8 4.6 10.8 4.6

3.0 12.1 4.8 12.1 4.8

3.5 12.8 5.0 12.8 5.0

4.0 12.8 5.2 12.8 5.2

Spacing table 671531.95X.1

Lamp luminous flux:

Mains: 1800 lm, Emergency: 1800 lm

The following values are indicated in m

h a b c d

2.5 13.0 5.2 13.0 5.2

3.0 13.1 5.6 13.1 5.6

3.5 14.3 5.8 14.3 5.8

4.0 15.1 6.1 15.1 6.1

Installation scheme available on request

Article number Type of installation

Lamps Mains/Emergency

Luminous flux factor

Lamp/Wattage PZ 50 (.03)

MultiDigit (.04)

DALI (.07)

Rated operat‑ing time

Dimensions

671587.96X.1.y Ceiling (surface), Wall (surface) 2 / 1 15 % 2 x TC‑DEL 18 W • • ‑ 3 h D 460, H 120

671700.34X.1.y Ceiling (surface), Wall (surface) 2 / 1 15 % 1 x TC‑TEL 18 W +

2 x TC‑TSE 18 W • • ‑ 3 h D 460, H 120

671531.95X.1.y Ceiling (surface), Wall (surface) 2 / 1 15 % 1 x TC‑DEL 26 W +

1 x TC‑DEL 26 W • • ‑ 3 h D 515, H 150

671585.86X.1.y Ceiling (surface), Wall (surface) 2 / 1 15 % 2 x TC‑F 36 W • • ‑ 3 h D 620, H 155

671911.95X.1.y Ceiling (surface), Wall (surface) 2 / 1 15 % 2 x TC‑DEL 26 W • • ‑ 8 h D 620, H 160

Series: Flat Polymero®

Type of protection: IP 40 Protection class: I

For escape route illumination

Base: metal, powder‑coated. Diffuser: plastic (PMMA), opal. Diffuser fastening: patented push lock.

operating mode: Can either be connected in non‑maintained power mode (BS) or in maintained power mode (DS).

Ballast mains/emergency: EB

Available colour (X): 2 = white

Planning guide: Escape route illumination in accordance with EN 1838

E = 1 lx along the centre line

D

H

D

H

D

H

78

30246

Ø460

Ø5

23

142

71

26325

Ø620

Ø5

325

h

d c b

a

Page 92: Emergency Lighting A1

90

EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES

Ceiling (surface), Wall (surface)

Flat Polymero® PC with collar Type of protection: IP 20

- Design continuity to the general lighting programme. We offer an extensive range of emergency lighting and general lighting systems. As such, we can provide our customers with integrated solutions for all areas of application, depending on their construction projects.

- Architecturally attractive design

- Compact design

- Easy to install

- With spring system - for opening the luminaire without tools - for gently detaching and positioning the diffuser

Page 93: Emergency Lighting A1

91

EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES

For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration

Ceiling (surface), Wall (surface) Ceiling (surface), Wall (surface)

Spacing table 671495.962

Lamp luminous flux:

Mains: 1200 lm, Emergency: 180 lm

The following values are indicated in m

h a b c d

2.5 5.2 2.0 5.2 2.0

3.0 5.8 1.9 5.8 1.9

3.5 4.9 1.6 4.9 1.6

4.0 4.8 1.1 4.8 1.1

Spacing table 671496.962

Lamp luminous flux:

Mains: 1800 lm, Emergency: 216 lm

The following values are indicated in m

h a b c d

2.5 5.7 2.2 5.7 2.2

3.0 5.9 2.2 5.9 2.2

3.5 5.6 2.0 5.6 2.0

4.0 5.6 1.7 5.6 1.7

Spacing table 671497.982

Lamp luminous flux:

Mains: 1200 lm, Emergency: 216 lm

The following values are indicated in m

h a b c d

2.5 5.9 2.3 5.9 2.3

3.0 6.1 2.3 6.1 2.3

3.5 5.7 2.1 5.7 2.1

4.0 5.9 1.8 5.9 1.8

Spacing table 671498.862 / 36 W

Lamp luminous flux:

Mains: 2800 lm, Emergency: 392 lm

The following values are indicated in m

h a b c d

2.5 7.6 3.1 7.6 3.1

3.0 8.3 3.2 8.3 3.2

3.5 8.2 3.2 8.2 3.2

4.0 8.3 3.1 8.3 3.1

Collar for general lighting height adjustment: see our latest product selection guide.

Article number Type of installation

Lamps Mains/Emergency

Luminous flux factor

Lamp/Wattage PZ 50 (.03)

MultiDigit (.04)

DALI (.07)

Rated operat‑ing time

Dimensions

671495.96X.y Ceiling (surface), Wall (surface) 1 / 1 15 % 1 x TC‑DEL 18 W • • ‑ 3 h D 310, H 190,

Ø 265

671496.95X.y Ceiling (surface), Wall (surface) 1 / 1 12 % 1 x TC‑DEL 26 W • • ‑ 3 h D 310, H 190,

Ø 265

671498.86X.y Ceiling (surface), Wall (surface) 2 / 1 15 % 2 x TC‑F 36 W • • ‑ 3 h D 420, H 205,

Ø 385

671497.98X.y Ceiling (surface), Wall (surface) 2 / 1 18 % 2 x TC‑L 18 W • • ‑ 3 h D 420, H 205,

Ø 385

Series: Flat Polymero® PC with collar

Type of protection: IP 20 Protection class: I

For escape route illumination

Base: plastic, white, with collar: perforated metal, powder‑coated. Diffuser: plastic (polycarbonate), opal. Diffuser fastening: spring system.

Ballast mains/emergency: EB

Available colour (X): 2 = white

Planning guide: Escape route illumination in accordance with EN 1838

E = 1 lx along the centre line

D

Ø

H

D

Ø

H

90

220266

525

3x120°

Ø6 50

3x120°

384,5335

5,5

h

d c b

a

Page 94: Emergency Lighting A1

92

EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES

Ceiling (surface), Wall (surface)

Flat Basic Type of protection: IP 43

- Design continuity to the general lighting programme. We offer an extensive range of emergency lighting and general lighting systems. As such, we can provide our customers with integrated solutions for all areas of application, depending on their construction projects.

- Architecturally attractive design

- Low maintenance costs

- Compact design

- Easy to install

- With spring system - for opening the luminaire without tools - for gently detaching and positioning the glass

Page 95: Emergency Lighting A1

93

EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES

For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration

Ceiling (surface), Wall (surface)

Spacing table 671423.912

Lamp luminous flux:

Mains: 600 lm, Emergency: 180 lm

The following values are indicated in m

h a b c d

2.5 6.9 2.6 6.9 2.6

3.0 7.0 2.6 7.0 2.6

3.5 7.2 2.5 7.2 2.5

4.0 6.8 2.3 6.8 2.3

Article number Type of installation

Lamps Mains/Emergency

Luminous flux factor

Lamp/Wattage PZ 50 (.03)

MultiDigit (.04)

DALI (.07)

Rated operat‑ing time

Dimensions

671423.91X.y Ceiling (surface), Wall (surface) 2 / 1 30 % 2 x TC‑EL 9 W • • ‑ 3 h D 420, H 124

Series: Flat Basic

Type of protection: IP 43 Protection class: I

For escape route illumination

Base: die‑cast aluminium, powder‑coated. opal glass: mouth‑blown, satin finish. Glass fastening: springs.

operating mode: Can either be connected in non‑maintained power mode (BS) or in maintained power mode (DS).

Ballast mains/emergency: LLB/EB

Available colour (X): 2 = white

Planning guide: Escape route illumination in accordance with EN 1838

E = 1 lx along the centre line

D

H

Ø

21495

50

400

5x8

258

h

d c b

a

Page 96: Emergency Lighting A1

94

EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES

Ceiling (surface), Wall (surface)

Flat Basic with collar Type of protection: IP 20

- Design continuity to the general lighting programme. We offer an extensive range of emergency lighting and general lighting systems. As such, we can provide our customers with integrated solutions for all areas of application, depending on their construction projects.

- Architecturally attractive design

- Low maintenance costs

- Compact design

- Easy to install

- With spring system - for opening the luminaire without tools - for gently detaching and positioning the glass

Page 97: Emergency Lighting A1

95

EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES

For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration

Ceiling (surface), Wall (surface) Ceiling (surface), Wall (surface)

Spacing table 671493.982

Lamp luminous flux:

Mains: 1200 lm, Emergency: 180 lm

The following values are indicated in m

h a b c d

2.5 6.9 2.6 6.9 2.6

3.0 7.0 2.6 7.0 2.6

3.5 7.2 2.5 7.2 2.5

4.0 6.8 2.3 6.8 2.3

Spacing table 671455.962

Lamp luminous flux:

Mains: 1200 lm, Emergency: 180 lm

The following values are indicated in m

h a b c d

2.5 6.9 2.6 6.9 2.6

3.0 7.0 2.6 7.0 2.6

3.5 7.2 2.5 7.2 2.5

4.0 6.8 2.3 6.8 2.3

Spacing table 671456.952

Lamp luminous flux:

Mains: 1800 lm, Emergency: 220 lm

The following values are indicated in m

h a b c d

2.5 7.2 2.9 7.2 2.9

3.0 7.8 2.9 7.8 2.9

3.5 7.5 2.9 7.5 2.9

4.0 8.2 2.8 8.2 2.8

Spacing table 671521.002

Lamp luminous flux:

Mains: 1800 lm, Emergency: 216 lm

The following values are indicated in m

h a b c d

2.5 6.9 2.7 6.9 2.7

3.0 6.9 2.7 6.9 2.7

3.5 7.1 2.6 7.1 2.6

4.0 6.6 2.4 6.6 2.4

Collar for general lighting height adjustment: see our latest product selection guide.

Spacing table 671494.862

Lamp luminous flux:

Mains: 2800 lm, Emergency: 392 lm

The following values are indicated in m

h a b c d

2.5 7.6 3.2 7.6 3.2

3.0 8.4 3.4 8.4 3.4

3.5 8.8 3.4 8.8 3.4

4.0 8.9 3.4 8.9 3.4

Article number Type of installation

Lamps Mains/Emergency

Luminous flux factor

Lamp/Wattage PZ 50 (.03)

MultiDigit (.04)

DALI (.07)

Rated operat‑ing time

Dimensions

671521.00X.y Ceiling (surface), Wall (surface) 2 / 1 12 % 2 x E27 25 W +

1 x TC‑DEL 26 W• • ‑ 3 h D 420, H 200,

Ø 265

671455.96X.y Ceiling (surface), Wall (surface) 2 / 1 15 % 2 x TC‑DEL 18 W • • ‑ 3 h D 420, H 200,

Ø 265

671456.95X.y Ceiling (surface), Wall (surface) 2 / 1 12 % 2 x TC‑DEL 26 W • • ‑ 3 h D 420, H 200,

Ø 265

671493.98X.y Ceiling (surface), Wall (surface) 2 / 1 18 % 2 x TC‑L 18 W • • ‑ 3 h D 500, H 205,

Ø 385

671494.86X.y Ceiling (surface), Wall (surface) 2 / 1 15 % 2 x TC‑F 36 W • • ‑ 3 h D 500, H 205,

Ø 385

Series: Flat Basic with collar

Type of protection: IP 20 Protection class: I

For escape route illumination

Especially for use with movement sensors and automatic staircase switches. Base: plastic with perforated metal collar, powder‑coated. opal glass: mouth‑blown, satin finish. Glass fastening: springs.

operating mode: Can either be connected in non‑maintained power mode (BS) or in maintained power mode (DS).

Ballast mains/emergency: EB

Available colour (X): 2 = white

Planning guide: Escape route illumination in accordance with EN 1838

E = 1 lx along the centre line

D

Ø

H

D

Ø

H

90

220266

525

3x120°

Ø6 50

3x120°

384,5335

5,5

h

d c b

a

Page 98: Emergency Lighting A1

96

EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES

Wall (surface) Ceiling (surface), Wall (surface)

Flat Polymero® Rechteck Type of protection: IP 40

- Design continuity to the general lighting programme. We offer an extensive range of emergency lighting and general lighting systems. As such, we can provide our customers with integrated solutions for all areas of application, depending on their construction projects.

- Design matches modern architectural styles

- Very large viewing distance with motifs

- Flat design

- Luminaire can be opened without tools

Page 99: Emergency Lighting A1

97

EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES

For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration

Wall (surface), Ceiling (surface)

Spacing table 671718.752

Lamp luminous flux:

Mains: 2400 lm, Emergency: 384 lm

The following values are indicated in m

h a b c d

2.5 8.3 3.1 8.3 3.1

3.0 8.7 3.2 8.7 3.2

3.5 9.0 3.1 9.0 3.1

4.0 9.1 3.0 9.1 3.0

Spacing table 671719.752

Lamp luminous flux:

Mains: 3500 lm, Emergency: 332 lm

The following values are indicated in m

h a b c d

2.5 7.7 2.9 7.7 2.9

3.0 8.0 2.9 8.0 2.9

3.5 8.3 2.8 8.3 2.8

4.0 8.3 2.6 8.3 2.6

Article number Type of installation

Viewing distance

Luminous flux factor

Lamp/Wattage PZ 50 (.03)

Multi‑Digit (.04)

DALI (.07)

Rated operat‑ing time

Dimensions

671718.75X.y Wall (surface), Ceiling (surface) 50 m 32 % 2 x T16 (T5) 14 W • • ‑ 3 h L 600, B 320, H 75

671719.75X.y Wall (surface), Ceiling (surface) 50 m 19 % 2 x T16 (T5) 24 W • • ‑ 3 h L 600, B 320, H 75

Series: Flat Polymero® Rechteck

Type of protection: IP 40 Protection class: I Viewing distance: 50 m

For escape route identification (only in case of wall installation) or escape route illumination

Base: metal, powder‑coated. Diffuser: plastic (PMMA), opal. Diffuser fastening: sash lock, plastic.

Please quote symbol number when ordering escape route motifs!

operating mode: Can either be connected in non‑maintained power mode (BS) or in maintained power mode (DS).

Ballast mains/emergency: EB

Mains operation: more than 1lamp Emergency mode: 1 lamp

When used as escape route luminaire, please note luminous flux factors.

Available colour (X): 2 = white

Planning guide: Escape route illumination in accordance with EN 1838

E = 1 lx along the centre line

50 m

L

B H

48 306245320

581

530600

Ø5,5

h

d c b

a

Page 100: Emergency Lighting A1

98

EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES

Ceiling (surface), Wall (surface)

Basic Type of protection: IP 43

- Design continuity to the general lighting programme. We offer an extensive range of emergency lighting and general lighting systems. As such, we can provide our customers with integrated solutions for all areas of application, depending on their construction projects.

- Architecturally attractive design

- Low maintenance costs

- Compact design

- Easy to install

- With spring system - for opening the luminaire without tools - for gently detaching and positioning the glass

Page 101: Emergency Lighting A1

99

EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES

For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration

Ceiling (surface), Wall (surface)

Spacing table 671095.912

Lamp luminous flux:

Mains: 600 lm, Emergency: 180 lm

The following values are indicated in m

h a b c d

2.5 5.8 1.9 5.8 1.9

3.0 5.6 1.7 5.6 1.7

3.5 5.4 1.2 5.4 1.2

4.0 ‑ ‑ ‑ ‑

Spacing table 671112.922

Lamp luminous flux:

Mains: 900 lm, Emergency: 126 lm

The following values are indicated in m

h a b c d

2.5 4.8 1.4 4.8 1.4

3.0 4.6 0.9 4.6 0.9

3.5 ‑ ‑ ‑ ‑

4.0 ‑ ‑ ‑ ‑

Spacing table 671422.912

Lamp luminous flux:

Mains: 600 lm, Emergency: 180 lm

The following values are indicated in m

h a b c d

2.5 5.8 1.9 5.8 1.9

3.0 5.6 1.7 5.6 1.7

3.5 5.4 1.2 5.4 1.2

4.0 ‑ ‑ ‑ ‑

Article number Type of installation

Lamps Mains/Emergency

Luminous flux factor

Lamp/Wattage PZ 50 (.03)

MultiDigit (.04)

DALI (.07)

Rated operat‑ing time

Dimensions

671112.92X.y Ceiling (surface), Wall (surface) 1 / 1 14 % 1 x TC‑DEL 13 W • • ‑ 3 h D 280, H 145

671095.91X.y Ceiling (surface), Wall (surface) 1 / 1 30 % 1 x TC‑EL 9 W • • ‑ 3 h D 280, H 145

671422.91X.y Ceiling (surface), Wall (surface) 2 / 1 30 % 2 x TC‑EL 9 W • • ‑ 3 h D 280, H 145

Series: Basic

Type of protection: IP 43 Protection class: I

For escape route illumination

Base: die‑cast aluminium, powder‑coated. opal glass: mouth‑blown, satin finish. Glass fastening: springs.

operating mode: Can either be connected in non‑maintained power mode (BS) or in maintained power mode (DS).

Ballast mains/emergency: LLB/EB

Available colour (X): 2 = white

Planning guide: Escape route illumination in accordance with EN 1838

E = 1 lx along the centre line

D

H

Ø

21495

50

280

5x8

258

h

d c b

a

Page 102: Emergency Lighting A1

100

EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES

Ceiling (surface), Wall (surface)

Kreis Type of protection: IP 43

- Design continuity to the general lighting programme. We offer an extensive range of emergency lighting and general lighting systems. As such, we can provide our customers with integrated solutions for all areas of application, depending on their construction projects.

- Design matches modern architectural styles

- Low maintenance costs

- Compact design

- Easy to install

- With spring system - for opening the luminaire without tools - for gently detaching and positioning the glass

Page 103: Emergency Lighting A1

101

EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES

For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration

Ceiling (surface), Wall (surface)

Spacing table 671425.912

Lamp luminous flux:

Mains: 600 lm, Emergency: 180 lm

The following values are indicated in m

h a b c d

2.5 5.8 1.9 5.8 1.9

3.0 5.6 1.7 5.6 1.7

3.5 5.4 1.2 5.4 1.2

4.0 ‑ ‑ ‑ ‑

Article number Type of installation

Lamps Mains/Emergency

Luminous flux factor

Lamp/Wattage PZ 50 (.03)

MultiDigit (.04)

DALI (.07)

Rated operat‑ing time

Dimensions

671425.91X.y Ceiling (surface), Wall (surface) 2 / 1 30 % 2 x TC‑EL 9 W • • ‑ 3 h D 280, H 120

Series: Kreis

Type of protection: IP 43 Protection class: I

For escape route illumination

Base: die‑cast aluminium, powder‑coated. opal glass: mouth‑blown, satin finish. Glass fastening: springs.

operating mode: Can either be connected in non‑maintained power mode (BS) or in maintained power mode (DS).

Ballast mains/emergency: LLB/EB

Available colour (X): 2 = white

Planning guide: Escape route illumination in accordance with EN 1838

E = 1 lx along the centre line

D

H

21495

50

280

5x8

258

h

d c b

a

Page 104: Emergency Lighting A1

102

EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES

Ceiling (surface), Wall (surface)

Rondo Type of protection: IP 43

- Design continuity to the general lighting programme. We offer an extensive range of emergency lighting and general lighting systems. As such, we can provide our customers with integrated solutions for all areas of application, depending on their construction projects.

- Design matches modern architectural styles

- Low maintenance costs

- Compact design

- Easy to install

- With spring system - for opening the luminaire without tools - for gently detaching and positioning the glass

Page 105: Emergency Lighting A1

103

EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES

For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration

Ceiling (surface), Wall (surface)

Spacing table 671427.912

Lamp luminous flux:

Mains: 600 lm, Emergency: 180 lm

The following values are indicated in m

h a b c d

2.5 6.6 2.3 6.6 2.3

3.0 6.6 2.1 6.6 2.1

3.5 6.4 1.8 6.4 1.8

4.0 6.2 1.1 6.2 1.1

Article number Type of installation

Lamps Mains/Emergency

Luminous flux factor

Lamp/Wattage PZ 50 (.03)

MultiDigit (.04)

DALI (.07)

Rated operat‑ing time

Dimensions

671427.91X.y Ceiling (surface), Wall (surface) 2 / 1 30 % 2 x TC‑EL 9 W • • ‑ 3 h D 400, H 125

Series: Rondo

Type of protection: IP 43 Protection class: I

For escape route illumination

Base: die‑cast aluminium, powder‑coated. opal glass: mouth‑blown, satin finish. Glass fastening: springs.

operating mode: Can either be connected in non‑maintained power mode (BS) or in maintained power mode (DS).

Ballast mains/emergency: LLB/EB

Available colour (X): 2 = white

Planning guide: Escape route illumination in accordance with EN 1838

E = 1 lx along the centre line

D

H

Ø

21495

50

400

5x8

258

h

d c b

a

Page 106: Emergency Lighting A1

104

EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES

Ceiling (surface), Wall (surface)

Rounded Maxi Type of protection: IP 55

- Design continuity to the general lighting programme. We offer an extensive range of emergency lighting and general lighting systems. As such, we can provide our customers with integrated solutions for all areas of application, depending on their construction projects.

- Design matches modern architectural styles

- Housing made of top quality die-cast aluminium

- Low maintenance costs

- Compact design

- Easy to install

- IP 55 type of protection - dustproof and protected against water jets

Page 107: Emergency Lighting A1

105

EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES

For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration

Ceiling (surface), Wall (surface)

Spacing table 671735.92X

Lamp luminous flux:

Mains: 3600 lm, Emergency: 216 lm

The following values are indicated in m

h a b c d

2.5 6.5 2.1 5.7 1.9

3.0 6.6 2.0 5.8 1.7

3.5 6.5 1.5 5.7 1.3

4.0 6.1 0.2 5.3 0.4

Article number Type of installation

Lamps Mains/Emergency

Luminous flux factor

Lamp/Wattage PZ 50 (.03)

MultiDigit (.04)

DALI (.07)

Rated operat‑ing time

Dimensions

671735.92X.y Ceiling (surface), Wall (surface) 2 / 1 14 % 2 x TC‑DEL 13 W • • ‑ 3 h D 400, H 130

Series: Rounded Maxi

Type of protection: IP 55 for indoor use Protection class: I

For escape route illumination

Mounting support and cover ring: powder‑coated aluminium; diffuser: opal glass, silk finish.

operating mode: Can either be connected in non‑maintained power mode (BS) or in maintained power mode (DS).

Ballast emergency/mains: EB

Available colours (X): 2 = white, 31 = anthracite metallic, 4 = silver metallic

Planning guide: Escape route illumination in accordance with EN 1838

E = 1 lx along the centre line

HD

260280

120Ø380

Ø400

Ø5

h

d c b

a

Page 108: Emergency Lighting A1

106

EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES

Ceiling (surface), Wall (surface) Ceiling (surface), Wall (surface)

Alu-Rund Type of protection: IP 54

- Design continuity to the general lighting programme. We offer an extensive range of emergency lighting and general lighting systems. As such, we can provide our customers with integrated solutions for all areas of application, depending on their construction projects.

- Housing made of sturdy die-cast aluminium

- Low maintenance costs

- Compact design

- Easy to install

- With glass cover

Page 109: Emergency Lighting A1

107

EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES

For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration

Ceiling (surface), Wall (surface) Ceiling (surface), Wall (surface)

Spacing table 671109.91X

Lamp luminous flux:

Mains: 600 lm, Emergency: 180 lm

The following values are indicated in m

h a b c d

2.5 6.7 2.5 6.7 2.5

3.0 6.9 2.3 6.9 2.3

3.5 7.1 1.9 7.1 1.9

4.0 6.3 1.4 6.3 1.4

Spacing table 671107.91X

Lamp luminous flux:

Mains: 600 lm, Emergency: 180 lm

The following values are indicated in m

h a b c d

2.5 6.7 2.5 6.7 2.5

3.0 6.9 2.3 6.9 2.3

3.5 7.1 1.9 7.1 1.9

4.0 6.3 1.4 6.3 1.4

Article number Type of installation

Type Luminous flux factor

Lamp/Wattage PZ 50 (.03)

MultiDigit (.04)

DALI (.07)

Rated operat‑ing time

Dimensions

671107.91X.y Ceiling (surface), Wall (surface)

without guard 30 % 1 x TC‑EL 9 W • • ‑ 3 h D 240, H 130

671109.91X.y Ceiling (surface), Wall (surface)

with guard 30 % 1 x TC‑EL 9 W • • ‑ 3 h D 240, H 130

Series: Alu-Rund

Type of protection: IP 54 for indoor use Protection class: I

For escape route illumination

Base: die‑cast aluminium, powder‑coated. opal glass. Guard: die‑cast aluminium, powder‑coated.

operating mode: Can either be connected in non‑maintained power mode (BS) or in maintained power mode (DS).

Ballast mains/emergency: EB

Available colours (X): 2 = white, 3 = black

Planning guide: Escape route illumination in accordance with EN 1838

E = 1 lx along the centre line

D H D H

62

65

42

240

6074

45

Ø6

62

65

42

240

6074

45

Ø6

h

d c b

a

Page 110: Emergency Lighting A1

108

EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES

Ceiling (surface), Wall (surface)

Weatherproof battens Type of protection: IP 65

- IP 65 type of protection - dustproof and protected against water jets from all directions

- Industrial design

- Lamp replacement without tools

Page 111: Emergency Lighting A1

109

EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES

For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration

Ceiling (surface), Wall (surface) 36 W Ceiling (surface), Wall (surface) 58 W

Spacing table 671093.759

Lamp luminous flux:

Mains: 3350 lm, Emergency: 436 lm

The following values are indicated in m

h a b c d

2.5 8.2 3.3 11.7 4.5

3.0 8.4 3.4 11.7 4.6

3.5 9.0 3.5 12.1 4.7

4.0 9.5 3.5 12.0 4.7

Spacing table 671446.759

Lamp luminous flux:

Mains: 5200 lm, Emergency: 432 lm

The following values are indicated in m

h a b c d

2.5 8.1 3.2 11.6 4.5

3.0 8.4 3.4 11.6 4.6

3.5 9.0 3.5 12.1 4.7

4.0 9.5 3.5 12.0 4.7

Article number Type of installation

Viewing distance

Luminous flux factor

Lamp/Wattage PZ 50 (.03)

MultiDigit (.04)

DALI (.07)

Rated operat‑ing time

Dimensions

671093.75X.y Ceiling (surface), Wall (surface) ‑ 13 % 1 x T26 (T8) 36 W • • ‑ 3 h L 1258, B 62, H 122

671446.75X.y Ceiling (surface), Wall (surface) ‑ 8 % 1 x T26 (T8) 58 W • • ‑ 3 h L 1558, B 62, H 122

Series: Weatherproof battens

Type of protection: IP 65 for indoor use Protection class: I

For escape route illumination

Base: plastic, grey. Lamp: open beam

operating mode: Can either be connected in non‑maintained power mode (BS) or in maintained power mode (DS).

Ballast mains/emergency: EB

Available colour (X): 9 = grey

Planning guide: Escape route illumination in accordance with EN 1838

E = 1 lx along the centre line

Accessories | Protective tubes for weatherproof battens

Replacement diffuser, plastictransparent981441.000 L 1170, D 38 for T26 36 W981442.000 L 1470, D 38 for T26 58 W

H

BL

H

BL

62

740

1258

Ø10

62

1050

1558

Ø10

h

d c b

a

Page 112: Emergency Lighting A1

110

EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES

Hand‑held LED safety spotlight Safety stand spotlight

Hand-held LED safety spotlight Type of protection: IP 54

- LED technology

- Charging level display

- Shockproof plastic housing

- Universal mounting adaptor included

Safety stand spotlight Type of protection: IP 54

- IP 54 type of protection - dustproof and protected against water spray

- Functional design

- Robust materials

- For high rooms

Page 113: Emergency Lighting A1

111

EMERGENCy LIGHTING | SELF‑CoNTAINED EMERGENCy LUMINAIRES

For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration

Hand‑held LED safety spotlight

Hand‑held LED safety spotlight

Safety stand spotlight

Safety stand spotlight

Article number Type of installation

Viewing distance

Luminous flux factor

Lamp/Wattage PZ 50 (.03)

MultiDigit (.04)

DALI (.07)

Rated operat‑ing time

Dimensions

671824.00X.y ‑ ‑ ‑ 1 x LED 3,35 W ‑ ‑ ‑ 4 h L 160, B 155, H 285

Article number Type of installation

Viewing distance

Luminous flux factor

Lamp/Wattage PZ 50 (.03)

Multi‑Digit (.04)

DALI (.07)

Rated operat‑ing time

Dimensions

65940 ‑ ‑ ‑ 2 x QT‑H3 55 W ‑ ‑ ‑ 1 h L 500, B 165, H 500

65942 ‑ ‑ ‑ 2 x QT‑H3 55 W ‑ ‑ ‑ 3 h L 500, B 165, H 500

65936 ‑ ‑ ‑ 2 x QT9 (axial) 20 W ‑ ‑ ‑ 1 h L 318, B 160, H 410

65938 ‑ ‑ ‑ 2 x QT9 (axial) 20 W ‑ ‑ ‑ 3 h L 500, B 165, H 500

Series: Hand-held LED safety spotlight

Type of protection: IP 54 Protection class: II in charging mode; Protection class: III in battery mode

Luminaire housing: plastic, grey. Ergonomically designed one‑hand handle, black. Front frame: plastic, red. Cover: polycarbonate, transparent, with four‑coloured light scatter disk attachment. Universal mounting adaptor: metal, painted. Integrated charger: 230 V at 50/60 Hz. Automatic changeover from quick to trickle charging.Preselec‑tion between static and flashing light mode possible. operation of the LED lamp at 100% or 10% performance. Maintenance‑free NiCd rechargeable battery 6 V / 4.0 Ah, charge status indicator.

Charge in dry rooms only!

operating time in static mode: LED lamp 100% > 4 h, LED lamp 10% > 13.5h

Available colour (X): 9 = grey

Series: Safety stand spotlight

Type of protection: IP 54 Protection class: I

Luminaire housing: metal, grey, powder‑coated. Luminaire tops: swivelling. Safety glass: transparent. Lamps included.

operating mode: Non‑maintained (BS), maintenance‑free Pb storage batteries.

B

L H

H

180

L B

Page 114: Emergency Lighting A1

112

NiCd-Akku

FL

654321

E

ST/AB-Bus

Prüftaster230V 50/60Hz

LEL‘NLPE rot

schwarz+

NiCd-Akku

FL

654321

E

ST/AB-Bus

Prüftaster

230V 50/60HzLEL‘NLPE rot

schwarz+

Lichtschalter

zurAllgemeinbe-

leuchtung

FL

Mit 2 Lampen

Mit 1 LampeKVG/VVG

KVG/VVG

Lichtschalter

zurAllgemeinbe-

leuchtung

S

S

S

(NiMH)

(NiMH)

Page 115: Emergency Lighting A1

113

Self-contained emergency conversion kits

Emergency conversion kits 114 - 116

Power supply units 116 - 117

Emergency power supply units 118

Connecting diagrams 119 - 121

Page 116: Emergency Lighting A1

114

EmErgEnCy Lighting | SELf-ContainEd ConvErSion kitS

Emergency conversion kits

Emergency lighting fitment

Power supply units

Conversion kits

System benefits

- High luminous flux factor reduces number of required luminaires

- Large LED display (5 mm)

- Constant light current control

- Complete series (standard, self-test, MultiDigit®)

- Universally suited for LLB/EB, irrespective of manufacturer

- Conversion kits for DALI available (upon request)

Universal installation kit for luminaires of general purpose lighting

ideally suited for converting general purpose lighting luminaires into self-contained emergency luminaires.

type of protection: iP 20 Protection class: i

Electronic module housing: metal, galvanised. Charging indicator lamp (LEd): standard. niCd high-temperature rechargeable battery and instructions for retrofitting this module into existing luminaires are included.

the modules conform to vdE0108 and En60598, part 2-22.

after conversion the luminaire can be operated in maintained or non-maintained power mode.

this module can be used together with the low-lost ballast (4-pin lamp holder, external starter required) or EB of the luminaire.

the ballast in the luminaire controls operation of the lamp(s) when mains power is applied. Should the mains power supply fail, one lamp is automatically powered by the battery via the emergency conversion kit.

Connecting diagramms: see pages 119 - 120

Please note:

Constant phase = charging phase,

must always be connected to L.

L’ and L must use the same phase.

The circuit must be potential-free.

Self-contained luminaire, maintained (DS)

L' L N PE

General purpose lighting

230 V / 50 Hz

Self-contained luminaire,non-maintained (BS)

L' L N PE

Sub distribution boardGeneral purpose lighting

General purpose lighting

230 V / 50 Hz

Sub distribution boardGeneral purpose lighting

Self-contained luminaire, maintained (DS)

L' L N PE

General purpose lighting

230 V / 50 Hz

Self-contained luminaire,non-maintained (BS)

L' L N PE

Sub distribution boardGeneral purpose lighting

General purpose lighting

230 V / 50 Hz

Sub distribution boardGeneral purpose lighting

Page 117: Emergency Lighting A1

115

EmErgEnCy Lighting | SELf-ContainEd ConvErSion kitS

tender texts available upon request | Specifications subject to alteration

the above indicated luminous flux factors are recommended hypothetical values for ambient temperatures of 25° C. inasmuch as colour rendering and luminous flux in emergency mode are mainly determined by lamp temperature and/or luminaire design and construction, light should be measured at lower temperatures for each type of luminaire. any lamp manufactured with amalgam techno-logy, such as the Philips PL-t toP, shall be excluded and shall be subject to prior testing. only quality products from reputable vendors are to be used. the values in the table above are intended as recommendations only and are subject to change. all applications shall be subject to prior testing. We reserve the right to effect changes in the table above without prior notice.t16/t5 tubes have a so-called “cold spot” at the tip of the tube, usually positioned at that tube tip which bears the lettering. for improved emergency mode, this cold spot or tube tip should be connected to outputs 6 and 8 of the lamp terminal. the luminaire should be marked in such a way as to ensure that the tube is inserted in the right direction.

Standard emergency conversion kits 6 – 80 W (battery included)

Nom. operating time 1h Nom. operating time 3h

Standard module

Catalogue number: 09-6284.000 09-6287.000

Self-test module (version .03)

Catalogue number: 09-6285.000 09-6288.000

MultiDigit® module (version .04)

Catalogue number: 09-6286.000 09-6289.000

Lamp/Wattage Luminous flux factor mains/emergency in %

t16 6 W 50 % 50 %t16 8 W 37 % 37 %t16 13 W 23 % 23 %t16 14 W 21 % 21 %t16 21 W 14 % 14 %t16 24 W 12 % 12 %t16 28 W 10 % 10 %t16 35 W 8 % 8 %t16 39 W 7 % 7 %t16 49 W 6 % 6 %t16 54 W 5 % 5 %t16 80 W 3 % 3 %t26 10 W 30 % 30 %t26 15 W 20 % 20 %t26 16 W 18 % 18 %t26 18 W 16 % 16 %t26 30 W 10 % 10 %t26 36 W 8 % 8 %t26 58 W 5 % 5 %tC-L 18 W 16 % 16 %tC-L 24 W 12 % 12 %tC-L 36 W 8 % 8 %tC-L 40 W 7 % 7 %tC-L 55 W 5 % 5 %tC-EL 5 W 50 % 50 %tC-EL 7 W 42 % 42 %tC-EL 9 W 33 % 33 %tC-EL 11 W 27 % 27 %tC-dEL 10 W 30 % 30 %tC-dEL 13 W 23 % 23 %tC-dEL 18 W 16 % 16 %tC-dEL 26 W 11 % 11 %tC-tEL 18 W 16 % 16 %tC-tEL 26 W 11 % 11 %tC-tEL 32 W 9 % 9 %tC-tEL 42 W - -t16-r 22 W 13 % 13 %t16-r 40 W 7 % 7 %t16-r 55 W 5 % 5 %t16-r 60 W 5 % 5 %t29-r 22 W 13 % 13 %t32-r 32 W 9 % 9 %t32-r 40 W 7 % 7 %

module dimensions 180 x 40 x 28 180 x 40 x 28Battery 4,8 v/1,8 ah 4,8 v/4,5 ahBattery dimensions d 24, L 2 x 88 d 33, L 242

Spare battery Spare battery 67000.0.61 67000.0.62

Emergency conversion kits with high luminous flux factor 14 – 80 W (battery included)

Nom. operating time 1h Nom. operating time 3h

Standard module

Catalogue number: 09-6290.000 09-6293.000

Self-test module (version .03)

Catalogue number: 09-6291.000 09-6294.000

MultiDigit® module (version .04)

Catalogue number: 09-6292.000 09-6295.000

Lamp/Wattage Luminous flux factor mains/emergency in %

t16 6 W - -t16 8 W - -t16 13 W - -t16 14 W 49 % 32 %t16 21 W 32 % 21 %t16 24 W 28 % 18 %t16 28 W 24 % 16 %t16 35 W 19 % 12 %t16 39 W 17 % 11 %t16 49 W 14 % 9 %t16 54 W 12 % 8 %t16 80 W 8 % 5 %t26 10 W 69 % 45 %t26 15 W 46 % 30 %t26 16 W 43 % 28 %t26 18 W 38 % 25 %t26 30 W 23 % 15 %t26 36 W 19 % 12 %t26 58 W 11 % 7 %tC-L 18 W 38 % 25 %tC-L 24 W 28 % 18 %tC-L 36 W 19 % 12 %tC-L 40 W 17 % 11 %tC-L 55 W 12 % 8 %tC-EL 5 W - -tC-EL 7 W - -tC-EL 9 W - -tC-EL 11 W - -tC-dEL 10 W - -tC-dEL 13 W - -tC-dEL 18 W 38 % 25 %tC-dEL 26 W 26 % 17 %tC-tEL 18 W 38 % 25 %tC-tEL 26 W 26 % 17 %tC-tEL 32 W 21 % 14 %tC-tEL 42 W 16 % 10 %t16-r 22 W 31 % 20 %t16-r 40 W 17 % 11 %t16-r 55 W 12 % 8 %t16-r 60 W 11 % 7 %t29-r 22 W 31 % 20 %t32-r 32 W 21 % 14 %t32-r 40 W 17 % 11 %

module dimensions 180 x 40 x 28 180 x 40 x 28Battery 4,8 v/4,5 ah 7,2 v/4,5 ahBattery dimensions d 33, L 242 d 33, L 2 x 182

Spare battery Spare battery 67000.0.62 67000.0.63*

* 2 batteries required

Page 118: Emergency Lighting A1

116

EmErgEnCy Lighting | SELf-ContainEd ConvErSion kitS

tender texts available upon request | Specifications subject to alteration

Emergency conversion kitsPower supply unitsIdeally suited for converting general purpose lighting luminaires into self-contained safety luminaires

type of protection: iP 30 Protection class: i

housing: metal, powder-coated. niCd rechargeable battery included.

the low-loss ballast (4-pin lamp holder, external starter required) or the EB of the luminaire to be converted powers the lamp in mains mode. the emergency light module automatically powers the lamp in emergency mode. Switching mode: either maintained mode or non-maintained mode. Luminaire equipment, power supply units: charging indicator (LEd), standard. maintenance-free niCd rechargeable batteries.

nominal operating time: 1 or 3 hours. max. length of cable between emergency supply unit and lamp: LLB = 2 m, EB = 0.5 m. Permissible ambient temperature: 0 -40° C. Luminous flux factors, see previous page.

available colours: 2 = white, 3 = black

Emergency conversion kit for fluorescent lampsin recessed or surface mounted housingL 390, B 100, H 55981158.003 1h 28 W 2.3 kg981158.003.03 1h 28 W 2.3 kg981158.003.04 1h 28 W 2.3 kg981159.003 3h 28 W 2.3 kg981159.003.03 3h 28 W 2.3 kg981159.003.04 3h 28 W 2.3 kg981160.003 1h 65 W 2.3 kg981160.003.03 1h 65 W 2.3 kg981160.003.04 1h 65 W 2.3 kg981161.003 3h 65 W 2.5 kg981161.003.03 3h 65 W 2.5 kg981161.003.04 3h 65 W 2.5 kg

Emergency conversion kit for fluorescent lampsin surface mounted housing, with luminaire suspension eyeletL 340, B 170, H 75981162.002 1h 28 W 1.7 kg981162.002.03 1h 28 W 1.7 kg981162.002.04 1h 28 W 1.7 kg981163.002 3h 28 W 1.7 kg981163.002.03 3h 28 W 1.7 kg981163.002.04 3h 28 W 1.7 kg981164.002 1h 65 W 1.7 kg981164.002.03 1h 65 W 1.7 kg981164.002.04 1h 65 W 1.7 kg981165.002 3h 65 W 1.9 kg981165.002.03 3h 65 W 1.9 kg981165.002.04 3h 65 W 1.9 kg

L

B

H

L

B

H

Page 119: Emergency Lighting A1

117

EmErgEnCy Lighting | SELf-ContainEd ConvErSion kitS

tender texts available upon request | Specifications subject to alteration

NCH complete conversion kitIdeally suited for converting general purpose lighting luminaires into self-contained emergency luminaires.

for low-voltage halogen lamps of up to 50 W, voltage: 6 v. nominal operating time: 1 or 3 hours.

housing: L 183, B 40, h 32rechargeable battery 6 v/4,0 ah: L 312, B 40, h 32.

09-6019.000 Qt max. 50 W 2 h/100 % 6 v 10 W

1 h/100 % 6 v 20 W

5 h/ 10 % 12 v 10 W

2 h/ 10 % 12 v 20 W

1 h/ 10 % 12 v 35 W

1 h/ 10 % 12 v 50 W

NCH safety conversion kitIdeally suited for converting general purpose lighting luminaires into self-contained safety luminaires

nominal operating time: 1 or 3 hours. max. length of cable between emergency supply unit and lamp: 1m. Luminous flux factors, see table on page 115.

Safety conversion kits for low-voltage halogen lamps in recessed or surface mounted housing (black module)

981127.003 L 390, B 100, h 55

in surface mounted housing, with luminaire suspension eyelet (white module)

981128.002 L 340, B 170, h 75

Luminous flux factors, see nCh complete conversion kit

(wattage/voltage see, nCh complete conversion kit)

L

B

H

L

B

H

L

L

H

B

B

H

Page 120: Emergency Lighting A1

118

EmErgEnCy Lighting | SELf-ContainEd ConvErSion kitS

tender texts available upon request | Specifications subject to alteration

Emergency power supply unit PGVG 200PGVG 200 is a self-contained emergency power supply unit pursuant to DIN EN 60598-2-22 for operating 1 or 2 luminaires over an operating period of 1 or 3 hours.

max. distance between Pgvg and luminaires: 200 m

type of protection: iP 33

Protection class: i

mains supply: 1/n 230 v; max. 0.25 a; 50 hz

output voltage: 230 v / 50 hz (mains) 170 – 225 v (battery)

Permissible ambient temperature: +5 to +25° C.

device is equipped with a protective earth connection.

Electronics

Electronic module with charging device, 2 mains monitors, 2 changeover facilities, dC-dC converter or dC-aC converter, 2 lighting circuits, deep discharge protection disconnection and automatic self-monitoring.

non-maintained or maintained power mode of the luminaires. Separate luminaire inputs and outputs as well as control inputs for switching the luminaires by lighting circuit in mains mode.

the battery is charged via input 1. in the event of a power failure on input 1 and/or input 2, the charging process will be interrupted and output 1 and/or 2 will be powered by the battery. Upon return of the mains power supply, the device switches back from battery to mains operation mode with a delay of 10 seconds.

in mains mode, the luminaires can be individually switched from non-maintained to maintained mode via control input 1 and control input 2.

the device switches off automatically in case of overheat, overload or short circuit during battery mode.

the standard self-monitoring function provides for automatic weekly function tests (charging device, changeover facility and lighting circuits) as well as yearly service life tests (battery capacity). the luminaires will be controlled by a self-adjusting rating monitor. a display and foil button indicate operating states and malfunctions and allow for manual activation of function tests. Collective errors can be forwarded to an external alarm system via an alarm output. Battery device with maintenance-free, sealed Pb battery (service life: 6 – 9 years according to EUroBat). the battery installation must comply with the manufacturer’s instructions. the battery must always be positioned with the pole pointing vertically upwards.

Luminaire 4 can be connected to terminals 5/6.

Mechanics

Battery and electronics are incorporated in separate housings according to din En 50272-2. Battery device with ventilation opening. Screwed housing can be folded open laterally. Wiring through cable ducts.

Similar to illustration

Types

Emergency power supply unit for operating 1 or 2 luminaires fitted with incandescent lamp or low pressure discharge lamp with electronic ballast, complying with self-contained system pursuant to din En 60598-2-22. the indicated wattages refer to the entire device and are divided among 2 outputs. the minimum wattage for lamp control is 13 w per output.

Catalogue no. type dimensions (LxBxh) Wattage981502.000 nvg200-7-dC-g 510 x 200 x 100 29 W/1h 12 W/3h

981504.000 nvg200-12-dC-g 510 x 200 x 170 50 W/1h 21 W/3h

981506.000 nvg200-18-dC-g 510 x 200 x 100 74 W/1h 31 W/3h

981508.000 nvg200-26-dC-g 510 x 200 x 170 106 W/1h 45 W/3h

981510.000 nvg200-45-dC-g 635 x 240 x 190 183 W/1h 78 W/3h

981512.000 nvg200-90-dC-g 950 x 240 x 190 200 W/1h 156 W/3h

N L2 L1

DATAPEL1NPEL2NPE

PE N (L2) L1

DATA

1

Connecting diagramm PGVG 200

256

A1

a1

PE

A2

a2

PE

4

3

L B

H

Page 121: Emergency Lighting A1

119tender texts available upon request | Specifications subject to alteration

EmErgEnCy Lighting | SELf-ContainEd ConvErSion kitS

the diagrams shown below refer to emergency conversion kits with the following article numbers

Standard Self test (.03) MultiDigit (.04)

09-6058.000 09-6042.000 09-6022.00009-6059.000 09-6043.000 09-6023.00009-6083.000 09-6044.000 09-6024.00009-6061.000 09-6045.000 09-6025.000

Attention: Connection diagrams with more than one lamp: one lamp starts in emergency mode.

in case your luminaires/EB are not suitable for these diagrams, please do not hesitate to contact us. We are looking forward to helping you.

Legend:

DA BUS connecting terminal for daLi interface .07

ST BUS connecting terminal for PZ 50, version with self test function .03

AB BUS connecting terminal, version for multidigit® .04

Connecting diagram 2: maintained, with CB/LLB for self-contained emergency conversion kits

Connecting diagram 1: non-maintained

Please note:

Constant phase = charging phase

must always be connected to L.

L’ and L must use the same phase.

The circuit must be potential-free.

Self-contained emergency conversion kits

Connecting diagrams

BUS portMultiDigit .04

PENLL' A B TSL' L N PE

BUS portPZ50 .03

BUS portDALI .07

PENLL' DADA

Page 122: Emergency Lighting A1

120

EmErgEnCy Lighting | SELf-ContainEd ConvErSion kitS

tender texts available upon request | Specifications subject to alteration

Connecting diagram 3: maintained, with EB

Self-contained emergency conversion kits

Connecting diagrams

EB with6 terminals

EB with7 terminals

EB with8 terminals

Page 123: Emergency Lighting A1

121

EmErgEnCy Lighting | SELf-ContainEd ConvErSion kitS

tender texts available upon request | Specifications subject to alteration

Self-contained emergency conversion kits

Connecting diagrams (Turia / Edo)

Turia / Edo: non-maintained, with DALI port

Turia / Edo: non-maintained

Turia / Edo: maintained, with DALI port

Turia / Edo: maintained

NLPE

NiMH-Akku

(NiCd)

+ red- black

230 V / 50/60 Hz

DADA

DALI BUSport

(NiCd)

NLPE

NiMH-Akku

+ red- black

230 V / 50/60 Hz

L'NLPE

NiMH-Akku

+ red- black

test button230 V / 50/60 Hz

light switchDADA

DALI BUSport

(NiCd)

L'NLPE

NiMH-Akku

+ red- black

test button230 V / 50/60 Hz

light switch

(NiCd)

Page 124: Emergency Lighting A1

122

Page 125: Emergency Lighting A1

123

Central battery systems (CPS) 127

RZBbasic central battery system with fused output circuits 128 - 131

LUXIFAIR modular central battery system 132 - 137

(Sub-stations can be connected)

LUXIFAIRlight modular central battery system 138 - 140

(Sub-stations cannot be connected)

Group battery systems (LPS) 141

GV 1500 19“ group battery system 142 - 143

RZBeasy group battery system 144 - 147

Accessories

Monitoring modules, message and switchboards, etc. 148 - 157

Battery cabinets 124 - 125

Page 126: Emergency Lighting A1

124

EMERGEncy LIGhtInG | cEntRAL BAttERy SyStEMS

tender texts available upon request | Specifications subject to alteration

charging

continuous charging

0% 20% 40% 60% 80% 100%

2.40 1.55

2.23 1.45

2.00 1.20

IN

V/Zlead NiCd

Battery cabinetsAll of the housings listed below are powder-coated and enamelled.

housing material: Sheet steel

type of protection: IP 21

colour: housing and doors RAL 7035 (light grey)

type Dimensions catalogue no.

RZB BS0 900 x 600 x 500 mm 985377 RZB BS8.20-3G 1800 x 600 x 600 mm 985238 RZB BS8.21-3G 1800 x 800 x 600 mm 985107

Other battery cabinets available on request.

All doors are right hinged. Free-standing housing doors open to an angle of 180 °. housing bases with a height of 100 or 200 mm are available for adjustment to other housings. All housings are available in other colours at extra cost.

cables can be channelled from below or above (rear) into the free-standing housings, but only from above in case of wall-mounted housings. cable inlets from above (rear) are standard for emergency lighting equipment.

the front and rear panels of all housings can be removed for transportation purposes.

Charging and charge maintenance devicethe charging and charge maintenance device’s functioning is based on the current voltage curve (I-U characteristics).

the charging device is powerful enough to ensure that the battery will be recharged to 80% of its nominal capacity within 12 hours. It can also be used to charge low-maintenance and maintenance-free batteries.

Charging voltage

2.40 V/Z ± 1% wet cell batteries

2.35 V/Z ± 1% maintenance-free batteries

1.55 V/Z ± 1% nicd batteries

Continuous charging voltage

2.23 V/Z ± 1% wet cell batteries

2.3 V/Z ± 1% maintenance-free batteries

1.4 - 1.45 V/Z ± 1% nicd batteries

Batteries- Sealed, rechargeable block batteries

- type: OGiV (other types on request)

- Designlife: 10 years at 20°c ambient temperature

- Extremely low gassing rate

- Low self-discharge

- Various capacities in 12 V blocks

- 100% recyclable

Page 127: Emergency Lighting A1

125

EMERGEncy LIGhtInG | cEntRAL BAttERy SyStEMS

tender texts available upon request | Specifications subject to alteration

Calculating the aeration and ventilation of electr. operation rooms

Larger battery capacities can be achieved by parallel arrangement of identical battery types.

Example:

If a battery capacity of 169 Ah and 216 V is required for 3 hours, 2 x 18 battery blocks, type BtX 12-100, are paralleled. this doubles the battery capacity from 84.60 to 168.20.

this type of arrangement is recommended fort he following battery types:

BtX 12-120 LS BtX 12-134 LS BtX 12-150 LS BtX 12-200 LS

Sta

tiona

ry, s

eale

d m

ain-

tena

nce-

free

lead

bat

tery

(O

GiV

)

Max

. lum

inai

re w

atta

ge

8h

Max

. lum

inai

re w

atta

ge

3 h

Max

. lum

inai

re w

atta

ge

1h

Air

volu

me

flow

Q [m

3 /h]

for

vent

ilatin

g th

e in

stal

latio

n ro

om

Ven

tilat

ion

cros

s se

ctio

ns

per

sup

ply

and

exh

aust

air

open

ing

in th

e in

stal

latio

n ro

om A

[cm

2 ] (n

atur

al

vent

ilatio

n)

Sq

uare

rec

ess

pe

r su

pply

and

exh

aust

air

op

enin

g, la

tera

l len

gth

[cm

]

Pip

epe

r su

pply

and

exh

aust

air

open

ing,

nom

inal

dia

met

er

[mm

]

num

ber

of b

atte

ry c

abin

ets

Bat

tery

cab

inet

sM

inim

um r

equi

rem

ents

for

use

of 1

8 bl

ocks

Dim

ensi

ons

of

batte

ry c

abin

et

[B x

t x

h]

17 Ah 429 W 1074 W 2786 W 0,78 m3/h 21,83 cm2 4,67 cm 52,73 mm 1 Stck BS 8.20 - 3G 600 x 600 x 1800

24 Ah 605 W 1414 W 3618 W 0,99 m3/h 27,80 cm2 5,27 cm 59,51 mm 1 Stck BS 8.20 - 3G 600 x 600 x 1800

28 Ah 761 W 1782 W 4417 W 1,18 m3/h 32,92 cm2 5,74 cm 64,76 mm 1 Stck BS 8.20 - 3G 600 x 600 x 1800

33 Ah 874 W 2030 W 4752 W 1,39 m3/h 39,02 cm2 6,25 cm 70,50 mm 1 Stck BS 8.20 - 3G 600 x 600 x 1800

45 Ah 1166 W 2548 W 5886 W 1,92 m3/h 53,65 cm2 7,32 cm 82,67 mm 1 Stck BS 8.20 - 3G 600 x 600 x 1800

55 Ah 1468 W 3261 W 7668 W 2,14 m3/h 59,99 cm2 7,75 cm 87,42 mm 1 Stck BS 8.20 - 3G 600 x 600 x 1800

75 Ah 2008 W 4179 W 9558 W 3,18 m3/h 89,01 cm2 9,43 cm 106,48 mm 1 Stck BS 8.20 - 3G 600 x 600 x 1800

80 Ah 2170 W 4644 W 10778 W 3,44 m3/h 96,32 cm2 9,81 cm 110,77 mm 1 Stck BS 8.21 - 3G 800 x 600 x 1800

90 Ah 2386 W 5119 W 12312 W 3,88 m3/h 108,52 cm2 10,42 cm 117,57 mm 1 Stck BS 8.21 - 3G 800 x 600 x 1800

100 Ah 2754 W 6145 W 14296 W 4,31 m3/h 120,71 cm2 10,99 cm 124,00 mm 1 Stck BS 8.21 - 3G 800 x 600 x 1800

120 Ah 3315 W 7171 W 17064 W 5,18 m3/h 145,09 cm2 12,05 cm 135,95 mm 2 Stck BS 8.21 - 3G 800 x 600 x 1800

134 Ah 3996 W 8996 W 20628 W 5,37 m3/h 150,46 cm2 12,27 cm 138,44 mm 1 Stck BS 8.21 - 3G 800 x 600 x 1800

150 Ah 4158 W 8888 W 21384 W 6,23 m3/h 174,36 cm2 13,20 cm 149,03 mm 2 Stck BS 8.20 - 3G 600 x 600 x 1800

200 Ah 5572 W 12528 W 28404 W 8,67 m3/h 242,64 cm2 15,58 cm 175,81 mm 2 Stck BS 8.21 - 3G 800 x 600 x 1800

Discharge data refer to 108 cells (18 blocs) at 25°.

Page 128: Emergency Lighting A1
Page 129: Emergency Lighting A1

127

EMERGEncy LIGhtInG | cEntRAL BAttERy SyStEMS

tender texts available upon request | Specifications subject to alteration

Central battery systems (CPS) in comparison

type of system RZBbasic LUXIFAIR LUXIFAIRlight

Modular technology • • •

Free programmable final circuits (maintained, non maintained) – • •

DUO control technology, mixed operati-on mode (maintained, non maintained, switchable mode)

– • •

circuit monitoring optional • •

Single luminaire monitoring (without BUS line) optional • •

with control 1 optional – –

Single control – • •

Duo control – • •

Switches

UE220i (for installation in luminaires)optional optional optional

UE220e (for installation in distribution boards) optional optional optional

Sub distribution board optional optional –

Sub-station (with same changeover and reporting functions as base) optional optional –

Visualisation – optional optional

network connection – • •

Staircase light switching optional • –

Voltage [V] 24/42/60/110/216 216 216

DS = maintained | BS = non-maintained | GDS = switched maintained | TLS = staircase light circuit

Page 130: Emergency Lighting A1

128

EMERGEncy LIGhtInG | cEntRAL BAttERy SyStEMS

RZBbasic

- Fully automated, processor-controlled monitoring system

- Modular structure

- Sheet steel cabinet

- Central monitoring of sub distribution boards

- Free programming of all system and customer data

- Single luminaire monitoring and circuit monitoring, optional

- Basic version with battery voltage 216 V (220 V), other battery voltages (24 V, 42 V, 60 V, 110 V) on request

- E30 or E90 twin cabinets can also be supplied upon request

Central battery system (CPS)

type of protection: IP 21 Protection class: I

RZBbasic is a series of modular systems; the number and the distribution of the circuits are to be determined beforehand. the system can be configured individually.

RZBbasic comes complete with a control unit, plastic foil keyboard and four-line display.

Available colour for housing and doors: RAL 7035 (light grey)

Additional RZBbasic options

Battery cabinet

page 124

Sub distribution boardpage 131

For more RZBbasic options: see page 148 et seqq.

Monitoring module

cOntROL1 for installation in luminaires

UE220i switch

for installation in luminaires

UE220e switch

for installation in distributors

Printer for operating status messages and testing protocols

3-phase network monitoring module

Message and switchboard

Page 131: Emergency Lighting A1

129

EMERGEncy LIGhtInG | cEntRAL BAttERy SyStEMS

tender texts available upon request | Specifications subject to alteration

RZBbasic installation example

Sub distribution board

Fused outlet circuits with circuit or single luminaire monitoring without changeover facility

In case of sub distribution boards with BUS connection, please note: if the sub distribution board is more than 100 m away from the main station, it must be fitted with a BUS amplifier. Max. BUS line length: 1,000 m.

the BUS can be connected in series or star-shaped (max. 6 star points). Each system provides 2 standard BUS terminals.

BU

S li

ne

Lum

inai

re (n

on m

aint

aine

d)

Lum

inai

re (m

aint

aine

d)

circuit 1

circuit 1

circuit 1

circuit 2

circuit 2

circuit 2

circuit 3

circuit 3

circuit 4

circuit 4

housing according to En 50272 and EltBau Vo

500

m

500

m 500 m

500 m

1000 m

Page 132: Emergency Lighting A1

130

EMERGEncy LIGhtInG | cEntRAL BAttERy SyStEMS

tender texts available upon request | Specifications subject to alteration

housing with charging and charge maintenance device

the housing is powder-coated and enameled. All doors are right-hinged. Free-standing housing doors open to an angle of 180 °. housing bases with a height of 100 or 200 mm are available for adjustment to other housings. All housings are available in other colours at additional cost.

Available as a twin cabinet with battery compartment or electronic housing with separate battery cabinet.

Technical specifications

Dimensions: 1800 x 800 x 600 mm, 1200 x 600 x 430 mm

Mains connection: type E – single-phase alternating current 230 V 50 hz

type D – three-phase current 400 V 50 hz

Mains voltage: Un ± 10%

Form factor: three-phase current: approx. 1.1; alternating current: approx. 1.4

Level of radio interference: „n“ according to VDE 0875

housing: Protection type IP 21

Available colour: housing and doors RAL 7035 (light grey)

Protection class: the appliances correspond to protection class I

Operating temperature: 0°c - 40°c at max. installation height of 1,000 m above zero level

Residual ripple: < 5% with parallel arranged battery

RZBbasic

Components

Microprocessor control and monitoring unit (standard)

- Illuminated plain text display: 4 lines with 16 characters each

- Plastic foil keyboard

- Buffer storage for reports and function tests dating back 2 years

- 4 integrated timers for maintained light circuits control

- Simple BUS connection of sub distribution boards

- Potential separation of the processor unit ensures high level of interference immunity

- Serial RS232 interface on the door for connection of a Pc for data collection (standard)

- central control unit interface: all reports with opening and closing contact

- Outgoing circuits can be individually programmed as maintained, non-maintained or switched maintained light

- Simple to service thanks to the plug-in connections on all modules

Microprocessor control and monitoring unit

2-pole fused outgoing circuits

Battery compartment with grid trays. the grid trays provide better ventilation, especially of the middle batteries, which prolongs their service life.

Page 133: Emergency Lighting A1

131

EMERGEncy LIGhtInG | cEntRAL BAttERy SyStEMS

tender texts available upon request | Specifications subject to alteration

Design: steel cabinet

Paint coating: housing and doors RAL 7035 (light grey)

type of protection: IP 21

Fitting: up to 36 x D01/D02 or 26 x circuit breakers

Fire-protected housing also avilable. A BUS interface circuit board can also be installed (necessary for circuit or single monitoring).

type Dimensions max. D01/LSS

E1/UV 600 x 400 x 250 16/14E2/UV 800 x 400 x 250 24/21

RZBbasic

Sub distribution boards

Design: steel cabinet

Paint coating: housing and doors RAL 7035 (light grey)

type of protection: IP 21

Ready for installation of changeover facilities, circuit monitoring or single luminaire monitoring and for BUS connection to the master device. the following must be installed if sub-stations with switching facilities are to be used:

1. control PcB

2. Bus interface PcB

3. network monitoring module for sub distribution board

4. Switching equipment, circuits, monitoring equipment

type Dimensions max. D01/D02/LSS

E3 UV 800 x 600 x 250 24/24/18nL8.21-UV 1800 x 800 x 400 79/79/60

Fire-protected housing E-30

Design: 30 minutes fire-protected housing, tested in line with DIn 4102 Part 12

Attention: Distributors and module cabinets are not equipped.

type Dimensions max. D01/LSS

t1 UV-E30 1000 x 730 x 400 housing for fuses 12/18

t2 UV-E30 1150 x 890 x 400 housing for fuses 30/30

t3 UV-E30 2050 x 730 x 400 Module cabinet 60/72

t4 UV-E30 2050 x 1230 x 400 Module cabinet 120/120

Page 134: Emergency Lighting A1

132

EMERGEncy LIGhtInG | cEntRAL BAttERy SyStEMS

- Fully automated, processor-controlled monitoring system

- Compact design of center board and sub-stations

- Mixed operation mode of all switching modes within one electric circuit

- Free choice of power source (Battery, EPS, second mains power supply)

- Single luminaire monitoring for DC and AC networks

- Integrated freely selectable single luminaire or circuit monitoring

- A PC can be connected for free programming of all system and customer data

- Single-wire technology to sub distribution boards

- Highly secure thanks to intelligent sub-stations with sub-masters for autonomous operation mode

- Integrated test log for function tests and events over a period of more than 4 years

- Remote maintenance via phone or internet

- SD card for programming, display texts, test log, etc.

- Programming software included

type of protection: IP 21 Protection class: I

RZB LUXIFAIR is a series of modular systems that can be configured individually.

Available colour for housing and doors: RAL 7035 (light grey)

For more LUXIFAIR options: see page 148 et seqq.

EcM (electric circuit module)

IO module 24 for potential-free contacts

IO module 230 for direct mains voltage

Single control for single luminaire monitoring

DUO control for single luminaire monitoring and mixed operation mode

Message and switchboard

Printer for operating status messages and testing protocols

Central battery system (CPS)

LUXIFAIR

Additional LUXIFAIR options

Battery cabinet

page 124

Sub distribution boardpage 131

Page 135: Emergency Lighting A1

133

EMERGEncy LIGhtInG | cEntRAL BAttERy SyStEMS

tender texts available upon request | Specifications subject to alteration

installation example

EIB

Sys

tem

Bus

Sec

ure

track

E30 fused junction box

E30 fused junction box

LUXIFAIR

circuit 1

circuit 2

circuit 3circuit 4

circuit 1

circuit 2

circuit 3

circuit 4

circuit 1

circuit 2

circuit 3

circuit 4

circuit 5

housing according to En 50272 and EltBau Vo

Page 136: Emergency Lighting A1

134

EMERGEncy LIGhtInG | cEntRAL BAttERy SyStEMS

tender texts available upon request | Specifications subject to alteration

Similar to illustration

Similar to illustration

Similar to illustration

housing: plastic/metal

connection: plug-in terminals, directly on the module

Available for: surface mounting

Dimensions: L 385 x B 295 x t 110 mm

no. of EcMs: 1

no. of circuits: 4 circuits

Fire-protected: optional (additional cost)

Manufacturer: RZB

type: UV-SK1

housing: plastic/metal

connection: plug-in terminals, directly on the module

Available for: surface mounting

Dimensions: L 385 x B 295 x t 110 mm

no. of EcMs: 2

no. of circuits: 8 circuits

Fire-protected: optional (additional cost)

Manufacturer: RZB

type: UV-SK2

housing: plastic/metal

connection: plug-in terminals, directly on the module

Available for: surface mounting

Dimensions: L 800 x B 600 x t 250 mm

no. of EcMs: 3

no. of circuits: 12 circuits

Fire-protected: optional (additional cost)

Manufacturer: RZB

type: UV-SK3

LUXIFAIR sub distribution board UV-SK1 985288 L 385, B 295, t 110 mm

LUXIFAIR sub distribution board UV-SK2 985289 L 385, B 295, t 110 mm

LUXIFAIR sub distribution board UV-SK3 985290 L 800, B 600, t 250 mm

Sub distribution boards

LUXIFAIR

4

8

12

Page 137: Emergency Lighting A1

135

EMERGEncy LIGhtInG | cEntRAL BAttERy SyStEMS

tender texts available upon request | Specifications subject to alteration

housing: plastic/metal

connection: plug-in terminals, directly on the module

Available for: surface mounting

Dimensions: L 800 x B 600 x t 250 mm

no. of EcMs: 4

no. of circuits: 16 circuits

Fire-protected: optional (additional cost)

Manufacturer: RZB

type: UV-SK4

housing: plastic/metal

connection: block terminals

Available for: surface mounting

Dimensions: L 800 x B 600 x t 250 mm

no. of EcMs: 5

no. of circuits: 20 circuits

Fire-protected: optional (additional cost)

Manufacturer: RZB

type: UV-SK5

housing: plastic/metal

connection: block terminals

Available for: surface mounting

Dimensions: L 800 x B 600 x t 250 mm

no. of EcMs: 6

no. of circuits: 24 circuits

Fire-protected: optional (additional cost)

Manufacturer: RZB

type: UV-SK6

Similar to illustration

Similar to illustration

Similar to illustration

LUXIFAIR sub distribution board UV-SK4 985291 L 800, B 600, t 250 mm

LUXIFAIR sub distribution board UV-SK5 985292 L 800, B 600, t 250 mm

LUXIFAIR sub distribution board UV-SK6 985293 L 800, B 600, t 250 mm

Version with IOM 230 or IOM 24 possible. Sub distribution boards can be configured to customer’s specific requirements.

Fire-protected version (E 30) available upon request.

Sub distribution boards

LUXIFAIR

24

20

16

Page 138: Emergency Lighting A1

136

EMERGEncy LIGhtInG | cEntRAL BAttERy SyStEMS

tender texts available upon request | Specifications subject to alteration

Master

Microprocessor control and monitoring unit

the Master is a freely programmable control unit that also acts as the communication interface. the Master can be supported by further sub-masters, which form their own self-enclosed systems, but are always managed by the Master and communicate with each other via the Master bus or exchange switching commands that apply to both Master and sub-masters. Each master/sub-master forms its own communication bus, thus preventing communication overload on the overall system’s bus systems.

the Master unit provides all of the monitoring functions required by the applicable VDE and En standards and is equipped with the following features:

- Illuminated blue-design-display: 4 lines with 20 characters each

- Plain text display of all reports

- 6 membrane buttons for operating the unit

- Operating states reports via LED

- Buffer storage for reports and function tests dating back more than 4 years

- USB – interface for connecting a Pc

- SD card for programming, display texts, test log etc.

- 3 RS232 interfaces for expansion modules (print box, visualisation, phone line box, etc.)

- Remote maintenance via phone or internet

- Visualisation of the entire system on incorporated or existing Pc (option)

- 8 freely programmable digital inputs

- Windows-compatible embOS (embedded operating system)

- Programmable function keys for rapid access to frequently used functions

- Plain text display of local emergency modes

- Automatic search for specific luminaire addresses

- 8 programmable switching options per electric circuit

LUXIFAIR Master is the system‘s central intelligence. It performs all of the monitoring, log and test functions stipulated in En 50172 and En 50171 and stores them on an SD card.

the emergency lighting system can be programmed using the illuminated display or very conveniently using a laptop/Pc. LUXIFAIR Master, standard version, is equipped with a USB port.

As an option the Master can also be integrated into a safety lighting sub-station.

housing: plastic, grey

Display: 4 x 20 characters

type of installation: top hat rail

Operation: 6 function keys or Pc via USB

Special features: 8 freely programmable inputs

Ports: 1x USB, 3x RS232 via RJ45 jacks

Dimensions: h 90 x L 157 x B 61

Space requirements: 9 module spaces (MS)

LUXIFAIR

Page 139: Emergency Lighting A1

137

EMERGEncy LIGhtInG | cEntRAL BAttERy SyStEMS

tender texts available upon request | Specifications subject to alteration

EC module installation example

Secure track

Note:

Mixed operation possible in each circuit.

Page 140: Emergency Lighting A1

138

EMERGEncy LIGhtInG | cEntRAL BAttERy SyStEMS

- Fully automated, processor-controlled monitoring system

- Battery and electronic housings made of sheet steel: can be set up separately. Dimensions: 900 x 600 x 500 mm, each housing

- Mixed operation mode (DUO Control module required)

- Single changeover of each final circuit; freely programmable for maintained mode, non- maintained mode, switched maintained mode and staircase light circuit

- Integrated freely selectable single luminaire / circuit monitoring

- A PC can be connected for free programming of all system and customer data

- Potential-free outputs for message forwarding

- Single luminaire monitoring with plain text indication of target location

- Illuminated blue-design-display: 4 lines with 20 characters each, on the housing door

- Plain text display of all reports

- 6 membrane buttons for operating the unit

- Buffer storage for reports and function tests dating back more than 4 years

- USB interface for connecting a PC

- Direct connection to ECM (continuous conduction mode)

- Programming software included

type of protection: IP 21 Protection class: I

the LUXIFAIRlight central battery system contains all of the components stipulated in VDE 0108, part 100, VDE 0100, part 718, En 50171 and En 50272.

Available colour for housing and doors: RAL 7035 (light grey)

For more LUXIFAIRlight options: see page 148 et seqq.

EcM (electric circuit module)

Single control for single luminaire monitoring

DUO control for single luminaire monitoring and mixed operation

Message and switchboard

Printer for operating status messages and testing protocols

the LUXIFAIRlight electronics housing and battery cabinet can be set up separately and can be installed wall mounted. the battery can be stored in a battery cabinet or on a support. Battery cabinets: see page 124. Supports are available on request.

Please note: max. battery capacity: 100 Ah!

Batteries are not included in the price.

Central battery system (CPS)

LUXIFAIRlight

Page 141: Emergency Lighting A1

139

EMERGEncy LIGhtInG | cEntRAL BAttERy SyStEMS

tender texts available upon request | Specifications subject to alteration

Battery cabinet and batteries are not included!

Larger battery cabinets are available on request.

installation example LUXIFAIRlight

circuit 1

circuit 2

circuit 3

circuit 4

housing in accordance with En 50272 and EltBauVO

Suitable battery cabinet, up to 45 Ah 900 x 600 x 500 985377

charging current EcM circuits LUXIFAIR Master Dimensions (mm) Article number

LUXIFAIRlight 4 max. 5 A 1 4 • 900 x 600 x 500 985366

LUXIFAIRlight 8 max. 5 A 2 8 • 900 x 600 x 500 985367

LUXIFAIRlight 12 max. 5 A 3 12 • 900 x 600 x 500 985368

LUXIFAIRlight 16 max. 5 A 4 16 • 900 x 600 x 500 985369

LUXIFAIRlight 20 max. 5 A 5 20 • 900 x 600 x 500 985370

LUXIFAIRlight 24 max. 5 A 6 24 • 900 x 600 x 500 985371

LUXIFAIRlight 28 max. 5 A 7 28 • 900 x 600 x 500 985372

LUXIFAIRlight 32 max. 5 A 8 32 • 900 x 600 x 500 985373

LUXIFAIRlight 36 max. 5 A 9 36 • 900 x 600 x 500 985374

LUXIFAIRlight 40 max. 5 A 10 40 • 900 x 600 x 500 985375

Page 142: Emergency Lighting A1

140

EMERGEncy LIGhtInG | cEntRAL BAttERy SyStEMS

tender texts available upon request | Specifications subject to alteration

LUXIFAIRlight

Master

Microprocessor control and monitoring unit

the Master is a freely programmable control unit that also acts as the communication interface. the Master can be supported by further sub-masters, which form their own self-enclosed systems, but are always managed by the Master and communicate with each other via the Master bus or exchange switching commands that apply to both Master and sub-masters. Each master/sub-master forms its own communication bus, thus preventing communication overload on the overall system’s bus systems.

the Master unit provides all of the monitoring functions required by the applicable VDE and En standards and is equipped with the following features:

- Illuminated blue-design-display: 4 lines with 20 characters each

- Plain text display of all reports

- 6 membrane buttons for operating the unit

- Operating states reports via LED

- Buffer storage for reports and function tests dating back more than 4 years

- USB – interface for connecting a Pc

- SD card for programming, display texts, test log etc.

- 3 RS232 interfaces for expansion modules (print box, visualisation, phone line box, etc.)

- Remote maintenance via phone or internet

- Visualisation of the entire system on incorporated or existing Pc (optional)

- 8 freely programmable digital inputs

- Windows-compatible embOS (embedded operating system)

- Programmable function keys for rapid access to frequently used functions

- Plain text display of local emergency modes

- Automatic search for specific luminaire addresses

- 8 programmabl switching options per electric circuit

LUXIFAIR Master is the system‘s central intelligence. It performs all of the monitoring, log and test functions stipulated in En 50172 and En 50171 and stores them on an SD card.

the emergency lighting system can be programmed using the illuminated display or very conveniently using a laptop/Pc. LUXIFAIR Master, standard version, is equipped with a USB port.

As an option the Master can also be integrated into a safety lighting sub-station.

housing: plastic, grey

Display: 4 x 20 characters

type of installation: top hat rail

Operation: 6 function keys or Pc via USB

Special features: 8 freely programmable inputs

Ports: 1x USB, 3x RS232 via RJ45 jacks

Dimensions: h 90 x L 157 x B 61

Space requirements: 9 module spaces (MS)

Page 143: Emergency Lighting A1

141

EMERGEncy LIGhtInG | cEntRAL BAttERy SyStEMS

tender texts available upon request | Specifications subject to alteration

Group battery systems (LPS) in comparison

type of system GV 1500 RZBeasy 202 RZBeasy 204

19” technology • – –

Modular technology • – –

tWIn technology,

mixed operation mode (maintained, non maintained, switchable mode) • • –

circuit monitoring • • •

Single luminaire monitoring

(without BUS wire)

with control 1 • – –

Switches

UE220i (for installation in luminaires) • • •

UE220e (for installation in distribution boards) • • •

number of circuits 4/8/12/16/20 2 4

Visualisation optional optional optional

network connection – optional optional

Voltage [V] Dc 230/216 V 230/220 V 230/220 V

DS = maintained | BS = non-maintained | GDS = switched maintained | TLS = staircase light circuit

Page 144: Emergency Lighting A1

142

EMERGEncy LIGhtInG | cEntRAL BAttERy SyStEMS

- Fully automated, processor-controlled monitoring system

- 19” slide in rack

- Sheet steel cabinet with control panel cover

- Single changeover of each final circuit; freely programmable for maintained mode, non- maintained mode, switched maintained mode and staircase light circuit

- Integrated freely selectable single luminaire or circuit monitoring

- A PC can be connected free programming of all system and customer data

- Single luminaire monitoring with plain text indication of target location

- Twin housing with battery compartment

Group battery system (LPS)

RZB GV 1500

type of protection: IP 21 Protection class: I

the GV 1500 group battery system contains all of the components stipulated in VDE 0108 part 100, VDE 0100 part 718, En 50171, and En50272.

Available colour for housing and doors: RAL 7035 (light grey)

For more group battery system options: see page 148 et seqq.

Monitoring module cOntROL1 for installation in luminaires

UE220i switch for installation in luminaires

UE220e switch for installation in distributors

3-phase network monitoring module

tWIn technology

Message and switchboard

Printer for operating status messages and testing protocols

Page 145: Emergency Lighting A1

143

EMERGEncy LIGhtInG | cEntRAL BAttERy SyStEMS

tender texts available upon request | Specifications subject to alteration

Batteries and connectors are not included.

TWIN control for group battery system (GV 1500)

three circuit modes (non-maintained, maintained and switched maintained) can be simultaneously switched and operated in mixed constellation in one single circuit, thus notably reducing the number of circuits.

tWIn control module for single luminaire monitoring, for installation in luminaires. Module for individually monitoring luminaires fitted with incandescent lamps, fluorescent lamps or LED with EB 2-120 W. Luminaire addresses are set using an externally accessible rotary code switch with integrated changeover switch.

TWIN Control for luminaire wattages of up to max. 500 W 985217

TWIN Control for luminaire wattages of up to max. 1500 W 985 218

Batteries for group battery system (GV 1500) - Sealed, rechargeable block batteries

- type: OGiV

- Designlife: 5 years at 20°c ambient temperature

- Extremely low gassing rate

- Low self-discharge

- 100% recyclable

- 18 batteries are needed

Batteries for group battery system (battery connector included)67000.0.152

type of system GV 1500/4 GV 1500/8 GV 1500/12 GV 1500/16 GV 1500/20

19” technology yes yes yes yes yes

„lightcontrol“ processor unit standard standard standard standard standard

no. of circuits 4 8 12 16 20

Freely programmable final circuit (maintai-ned, non-maintained, switched maintained mode and staircase light circuit)

yes yes yes yes yes

circuit monitoring standard standard standard standard standard

Single luminaire monitoring without bus line, with control 1 standard standard standard standard standard

tWIn control optional optional optional optional optional

Light switch setting sensor module optional optional optional optional optional

Wattage 1h 1500 W 1500 W 1500 W 1500 W 1500 W

Wattage 3h 500 W 500 W 500 W 500 W 500 W

Visualisation optional optional optional optional optional

Voltage 230/216 V 230/216 V 230/216 V 230/216 V 230/216 V

housing

Free-standing cabinet, twin

cabinet (1200 x 600 x 430)

Free-standing cabinet, twin

cabinet (1200 x 600 x 430)

Free-standing cabinet, twin

cabinet (1200 x 600 x 430)

Free-standing cabinet, twin

cabinet (1200 x 600 x 430)

Free-standing cabinet, twin

cabinet (1200 x 600 x 430)

catalogue number 985212 985213 985214 985215 985216

DS = maintained | BS = non-maintained | GDS = switched maintained | TLS = staircase light circuit

Page 146: Emergency Lighting A1

144

EMERGEncy LIGhtInG | cEntRAL BAttERy SyStEMS

- Fully automated, processor-controlled monitoring system

- For decentralized power supply to safety luminaires within one fire compartment

- Sheet steel cabinet

- Single luminaire / circuit monitoring

- TWIN Control (mixed operation mode: maintained and non-maintained within one circuit (RZBeasy 202))

- Easy to set up

- Network connection (optional)

- Twin housing with battery compartment

type of protection: IP 21 Protection class: I

Available colour for housing and doors: RAL 7035 (light grey)

Group battery system (LPS)

RZBeasy 202 / 204 For more group battery system options: see page 148 et seqq.

3-phase network monitoring module

Message and switchboard

Electronic switch for dimming operation UE-DIM

Electronic switch with voltage control

tWIn technology

Page 147: Emergency Lighting A1

145

EMERGEncy LIGhtInG | cEntRAL BAttERy SyStEMS

tender texts available upon request | Specifications subject to alteration

RZBeasy 202 / 204 installation example (Circuit monitoring)

circuit 1

RZBeasy

RZBeasy

RZBeasy

circuit 2

circuit 3

circuit 4

circuit 1

circuit 2

circuit 3

circuit 4

circuit 1

circuit 2

circuit 3

circuit 4

Page 148: Emergency Lighting A1

146

EMERGEncy LIGhtInG | cEntRAL BAttERy SyStEMS

tender texts available upon request | Specifications subject to alteration

RZBeasy 202 / 204 calculation example

Battery included.

Total maximum wattage: 200 W !

type of system RZBeasy 202 RZBeasy 202 RZBeasy 204 RZBeasy 204

Rated operating time 1h 3h 1h 3h

Max. total wattage 200 W 200 W 200 W 200 W

Single luminaire control • • – –

tWIn control • • – –

circuit monitoring • • • •

no. of circuits 2 2 4 4

Max. no. of luminaires 32 32 80 80

Max. wattage per circuit 120 W 120 W 50 W 50 W

Min. wattage per circuit – – 15 W 15 W

Output voltage Ac/Dc 230 V / 220 V 230 V / 220 V 230 V / 220 V 230 V / 220 V

network of up to 25 pcs. optional optional optional optional

housing twin housing twin housing twin housing twin housing

Dimensions (822 x 414 x 220) (822 x 414 x 220) (822 x 414 x 220) (822 x 414 x 220)

catalogue number 985398 985399 985396 985397

RZBeasy 202 RZBeasy 204

P max. P max. P total

circuit 1 circuit 2 circuit 1 circuit 2 circuit 3 circuit 4

120 W 80 W 60 W 60 W 40 W 40 W 200 W

100 W 100 W 50 W 50 W 50 W 50 W 200 W

80 W 120 W 40 W 40 W 60 W 60 W 200 W

Page 149: Emergency Lighting A1

147

123

456

11121314

1516

3132333435363738

3940

4142

21 22 20 23 24 20 25 26 20 27 28 20

F21 F22 F23 F24 F25 F26 F27 F28

F2

F1

F3

F4

F29

EMERGEncy LIGhtInG | cEntRAL BAttERy SyStEMS

tender texts available upon request | Specifications subject to alteration

RZBeasy 202 / 204 connecting diagramcircuit direction

Button LM test

LED LM test

Ec-Interface

Address input

Address

Mains mode signalMP

MP

12 VDc plus12 VDc minus

network monitoring 12 V nWc+nW

Battery mode signal

Message emergency mode disabled

Error message contact - no error

Error message contact - error

Module

Luminaire group 2Output 2a

n /

min

usL

/ pl

usea

rth

Output 2bn

/ m

inus

L /

plus

eart

h

Luminaire group 1Output 1a

Emergency lighting blocking - F

critical circuit / mains monitor

Maintained, group 1

PE (Mains connection)n (Mains connection)L (Mains connection)

Maintained, group 2

Maual control, non-maintained (BS)Fire detection system switch

Emergency lighting blocking - f

n /

min

usL

/ pl

usea

rth

Output 1b

n /

min

usL

/ pl

usea

rth

Page 150: Emergency Lighting A1

148

EMERGEncy LIGhtInG | cEntRAL BAttERy SyStEMS

Accessories

type RZBbasic LUXIFAIR LUXIFAIRlight GV 1500 RZBeasy

3-phase network monitoring module • • • • •

Message and switchboard (surface mounting) • • • • •

Printer for operating status messages and testing protocols • • • • –

UE220i switch for installation in luminaires • • • • •

UE220e switch for installation in distributors • • • • •

Electronic switch for dimming operation • • • • •

Electronic switch with voltage control • • • • •

EcM (electric circuit module) – • • – –

IOM 24 for potential-free contacts – • – – –

IOM 230 for direct power supply voltage – • – – –

SInGLE cOntROL for single luminaire monitoring – • • – –

DUO cOntROL for single luminaire monitorin-gand mixed operation

– • • – –

Monitoring module cOntROL1 optional – – • –

tWIn technology – – – • •

Remote control tableau, type: MtB-BUS – – – • –

Universal changeover unit, type: UUE 4/220 / 4/220-80 – – – • –

Light switch setting sensor modules (LSM)

LSM 24 – – – • –

LSM 230 – – – • –

LSM 24/230 – – – • –

Page 151: Emergency Lighting A1

149

EMERGEncy LIGhtInG | cEntRAL BAttERy SyStEMS

tender texts available upon request | Specifications subject to alteration

3-phase network monitoring module

3-phase network monitoring module for all systems 985147 L 59, B 35, h 59

type of protection: IP 20

Protection class: II

Input voltage: 230/400 V 50/60 hz

Own rating: < 4VA

Min. operating value: 85% of nominal voltage

contact set: 2 change-over relays, potential-free

Installation: c profile track

Display: LED OFF if power fails

Suiteable for installation in systems complying with DIn VDE 0108.

For installation in sub distribution boards for detecting undervoltage and power failures in single-phase or three-phase power systems. construction width: 35 mm.

Printer for RZBbasic, LUXIFAIR, LUXIFAIRlight and GV 1500 985138 L 100, B 100, h 50

Printer for operating status messages and testing protocols

VDE 0108 Part 100 stipulates that emergency lighting operated by central battery system must be function-tested every day of operation and the results be recorded in a protocol. Manual testing and recording in writing can be eliminated by implementation of an automatic testing facility with protocol printer.

All errors and system status changes are recorded with indication of date and time.

the elimination of the faults is indicated with date and time.

Message and switchboard (surface mounting) without battery

for RZBbasic and GV 1500 985256 L 70, B 54, h 135

for LUXIFAIR and LUXIFAIRlight 985364 L 70, B 54, h 135

for RZBeasy 202 / 204 985402 L 150, B 40, h 200

type of protection: IP 32

Protection class: II

In accordance with DIn VDE 0100 part 718

Displays: - Operational readiness of the system

- Battery mode

- collective error

Switches: maintained mode On/OFF

Installation: surface mounting

housing: plastic, grey

terminals: 1.5 mm2

Message and switchboard (surface mounting)

AccESSORIES FOR ALL cPS AnD LPS SyStEMS

B L

H

L

H

B

Page 152: Emergency Lighting A1

150

EMERGEncy LIGhtInG | cEntRAL BAttERy SyStEMS

tender texts available upon request | Specifications subject to alteration

Electronic switch for luminaires with electronic ballasts (EB) and incandescent lamps in emergency lighting systems according to DIN VDE 0108

thanks to the UE220i switch, luminaires can be used both for general and for emergency lighting.

When voltage is present on the emergency power supply, the switch disconnects the luminaire from the general lighting power supply system. the time lag in switching eliminates any spark gaps in the changeover facility (relays), thus ensuring safe disconnection from the power supply.

UE220i is a switch for installation in luminaires; the relevant installation instructions must be followed.

Input voltage: General lighting power supply: 230 V Ac (+/- 10%)

Emergency power supply: 220 V Dc (+/- 20%)

Ambient temperature: -5 to +50 °c

changeover time: 100 ms

Switching power: 250 VA (short circuit proof 20 x Inom)

housing: plastic, black

Suiteable for installation in systems complying with DIn VDE 0108-100 En50172.

UE220i switch for all systems 981352.003 L 130, B 46, h 31

UE220e electronic switch for C and top hat rail (installation in distribution boards)

thanks to the UE220e switch, luminaires can be used simultaneously both for general and for emergency lighting. When voltage is present on the emergency power supply, the switch disconnects the luminaire from the general lighting power supply system.

Input voltage: General lighting power supply: 230 V Ac (+/- 10%)

Emergency power supply: 220 V Dc (+/- 20%)

Ambient temperature: -5 to +50 °c

changeover time: 100 ms

Switching power: 500 VA (short circuit proof 20 x Inom)

housing: plastic, grey

Suiteable for installation in systems complying with DIn VDE 0108-100 En50172.

UE 220e for all systems 981353.009 L 96, B 48, h 50

UE220i switch for installation in luminaires Installation example

UE220e switch for installation in distribution boards

Installation example UE220i (in luminaire)Please note:UE220e can only be installed in a distribution board.

Non-maintained circuit

Mains light switchGeneral lighting

Switching capacity:250VA

EB

Ue220i

LuminaireGroup batteryCentral battery

L+-

NNL+

-

NL

PF

Non-maintained circuit

Mains light switchGeneral lighting

Switching capacity:250VA

EB

Ue220i

LuminaireGroup batteryCentral battery

L+-

NNL+

-

NL

PF

Non-maintained circuit

Mains light switchGeneral lighting

Switching capacity:250VA

EB

Ue220i

LuminaireGroup batteryCentral battery

L+-

NNL+

-

NL

PF

AccESSORIES FOR ALL cPS AnD LPS SyStEMS

B

L

H

H

L

B

Page 153: Emergency Lighting A1

151

EMERGEncy LIGhtInG | cEntRAL BAttERy SyStEMS

tender texts available upon request | Specifications subject to alteration

Switching module for operating dimmable, combined safety luminaires on mains and emergency power supplies

Version for:- Selective changeover from non-maintained to maintained power mode during mains operation, depending on the switching mode of the general lighting- Dimming luminaires in mains mode via a 1-10V interface- Dimming luminaires in emergency mode via integrated potentiometer

Control: - Switched phase on general lighting system

- 1-10V signal from lighting control

Input voltage: General lighting power supply: 230 V Ac (+/- 10%) Emergency power supply: 220 V Dc (+/- 20%)

Ambient temperature: -5 to +50 °c

changeover time: 100 ms

Switching power: 250 VA (short circuit proof 20 x Inom)

housing: plastic, grey

Suiteable for installation in systems complying with DIn VDE 0108-100 En50172.

UE-DIM for all systems 09-6230.000 L 175, B 42, h 32

Electronic switch for dimming operation

Switching module for operating dimmable, combined safety luminaires on mains and emergency power supplies

Version for:- Selective changeover from non-maintained to maintained power mode during mains operation, depending on the switching mode of the general lighting- Selective activation in emergency mode depending on the general lighting power supply

Control: - Switched phase on general lighting system

- non- switched phase on general lighting system

- codable function

Input voltage: General lighting power supply: 230 V Ac (+/- 10%)

Emergency power supply: 220 V Ac/Dc (+/- 20%)

Ambient temperature: -5 to +50 °c

changeover time: 100 ms

Switching power: 250 VA (short circuit proof 20 x Inom)

housing: plastic, black

Suiteable for installation in systems complying with DIn VDE 0108-100 En50172.

TW 200 for all systems 09-6202.009 L 130, B 45, h 32

Electronic switch with voltage control

Non-maintained circuit

Mains light switch

External light control for EB with 1-10 V control

Group batteryCentral battery

Switching capacity:250VA

EBUE-DIM

Luminaire

L+-

NNL+

-

NL

PF

1 2 3

Non-maintained circuit

External light control for EB with 1-10 V control

Group batteryCentral battery

Switching capacity:250VA

EB

SwitchTW 200

Luminaire

Network monitoring

General lightingMains light switch

L

+-

NNL+

-

NL

PF

L inactiv

activ

AccESSORIES FOR ALL cPS AnD LPS SyStEMS

B

L

H

H

L B

Page 154: Emergency Lighting A1

152

EMERGEncy LIGhtInG | cEntRAL BAttERy SyStEMS

tender texts available upon request | Specifications subject to alteration

ECM (electric circuit module)

the Ec module is a bus-controlled electric circuit switching module. Fitted with a range of comfortable features, it offers both superior operational reliability and comprehensive monitoring technology. the safety or escape route luminaires are operated via the Ec module. All 4 output circuits on the module can be used both for circuit-monitored systems and for single luminaire monitoring.

Each module can operate 4 outgoing circuits with up to 20 luminaires each. Each outgoing circuit is protected by a 6.3 A (2-pole) fuse and can be switched individually. Max. voltage per electric circuit: 815 VA.

Each circuit of the lighting circuit assembly can be programmed in maintained power mode, non-maintained power mode, switched maintained power mode or mixed operation. the switching commands are transmitted via the mains power supply cable to the luminaire, without the need for an additional bus line. Single luminaire monitoring is also possible with the use of an nEA or secondary secured power supply as substitute source of power without the need for an additional test battery.

Each circuit can be switched via the IO-module. Status LEDs display the switching states of the outgoing circuits as well as the emergency mode. Error LEDs display fuse failures, luminaire malfunctions and overloads, thus facilitating troubleshooting considerably.

the information button offers the option of multiple error selection. the ES module is suitable for use in the base, in intelligent sub-stations or, as separate entity, for supplying individual fire compartments. It is connected to the master unit via the system bus.

ECM (electric circuit module)

Rating per circuit: 815 VA

Rating per module: 3260 VA

Fuse protection per circuit: 6.15 Ampere, 2-pole

connecting terminals: plug-in terminals, up to 1.5 mm²

circuit monitoring: standard

Addressing: 2 rotary code switches

Dimensions: L 157 x B 61 x h 90

Space requirement: 6 module spaces (MS)

type of installation: top hat rail

housing: plastic, grey

Secure track

max. 20 luminaires or 815 VA

Note:

Mixed operation possible in each circuit.

max. 20 luminaires or 815 VA

max. 20 luminaires or 815 VA

max. 20 luminaires or 815 VA

ECM installation example

ECM for LUXIFAIR and LUXIFAIRlight 985272 L 157, B 61, h 90

EIB System Bus

AccESSORIES FOR LUXIFAIR AnD LUXIFAIRlight

Page 155: Emergency Lighting A1

153

EMERGEncy LIGhtInG | cEntRAL BAttERy SyStEMS

tender texts available upon request | Specifications subject to alteration

IO-Modul Light switch setting sensor modules

these modules allow for final circuit switching in mains mode using the switches or contactors of the mains power supply lighting.

the IO modules are suitable for installation in the base or sub-station. they are connected to the base via the 2-core system bus. the IO modules are programmed via the LUXIFAIR master unit.

IOM 24 for potential-free contacts

the input ports can interrogate a maximum of 16 circuits.

Each input can be assigned to one or several outgoing circuits. Requests are transmitted via potential-free contacts. Each input had a LED status display.

contacts: 16 x 24 V via external potential-free contacts

type of installation: top hat rail

connecting terminals: up to 1.5 mm²

Addressing: 2 rotary code switches

Dimensions: L 105 x B 61 X h 90

Space requirement: 6 module spaces (MS)

housing: plastic, grey

IOM 24 for LUXIFAIR 985273 L 105, B 61 , h 90

IOM 230 for direct power supply voltage

the input ports can interrogate a maximum of 9 circuits.

Each input can be assigned to one or several outgoing circuits. Requests are transmitted via 230 V Ac.

3 LEDs display the status of the power monitoring module. the master unit displays the power failure of the IO module with programmable plain text indication of location.

the IOM 230 can be configured with:

9 x 230 V Ac switch inputs or

6 x 230 V switch inputs + 3ph network monitoring module or

8 x 230 V switch inputs + 1ph network monitoring module

Each input has a LED status display.

type of installation: top hat rail

connecting terminals: up to 1.5 mm²

Addressing: 2 rotary code switches

Dimensions: L 105 x B 61 X h 90

Space requirement: 6 module spaces (MS)

housing: plastic, grey

IOM 230 for LUXIFAIR 985274 L 105, B 61, h 90

AccESSORIES FOR LUXIFAIR AnD LUXIFAIRlight

X1: 1 3 5 7 9 11 13 152 4 6 8 10 12 14 16E1 E2 E3 E4 E5 E6 E7 E8

Digitale Eingänge f.pot.-freie Kontakte

h 17 19 21 23 25 27 29 3118 20 22 24 26 28 30 32E9 E10 E11 E12E13E14E15E16

V

X1: 41 42 43 44

X1: 1n 1L 2n 2L 3n 3L 4n 4L 5n 5L 6n 6L

Digitale Eingänge für 230VAcKontaktbelegung n - L

X1: 41 42 43 44

E1 E2 E3 E4 E5 E6

E9 E8 E7 nL1 L2 L3

Page 156: Emergency Lighting A1

154

EMERGEncy LIGhtInG | cEntRAL BAttERy SyStEMS

tender texts available upon request | Specifications subject to alteration

SINGLE Control for single luminaire monitoring

Module for monitoring single luminaires of 2-120 W. Luminaire addresses are set using an externally accessible rotary code switch.

type of protection: IP 20

Dimensions: L 81 x B 33 x h 24

Input voltage 230 V Ac (+ 10% / - 15%) 230 V Dc (+ 20% / - 20%)

housing: plastic, grey

Single Control for LUXIFAIR and LUXIFAIRlight 985280 L 81, B 33, h 24

DUO Control for single luminaire monitoring and mixed operation mode

Module for monitoring single luminaires of 2-120 W. the use of a DUO control module allows for mixed operation of maintained and non-maintained luminaires within the same circuit. Individual circuits can be switched using the inputs of the IO module. Luminaire addresses can be set manually using an externally accessible rotary code switch.

the DUO control module is also fitted with an invertible switch input.

type of protection: IP 20

Dimensions: L 81 x B 33 x h 24

Input voltage: 230 V Ac (+10% / -15%) 230 V Dc (+20% / -20%)housing: plastic, grey

Duo Control LUXIFAIR and LUXIFAIRlight 985279 L 81, B 33, h 24

LUXIFAIRCentral battery

Output circuits from central battery system

Outputmax. 120W SINGLE

Control

EB

Address allocation module is to be addressed!

Address Single +Tens1 = 0 +110 = 10 +111 = 10 +120 = 20 +0

++

2010

00

Address +20Address +10

2-6 W 8-120W

00

Output max.120 WN-

L+

N-

L+

SINGLE Controlfor EB and incandescent lamps 2-120 W

Please note:+ and - must not be reversed!

LUXIFAIRCentral battery

Output circuits from central battery system

Outputmax. 120W DUO

Control

EB

Address allocation module is to be addressed!

Address Single +Tens1 = 0 +110 = 10 +111 = 10 +120 = 20 +0

++

2010

00

Address +20

Address +10

2-6 W 8-120W

0

0

N-

L+

N-

L+

N-

L+

Network monitoring InputDS BS

DUO Controlfor EB and incandescent lamps 2-120 W

Please note:+ and - must not be reversed!

The following can be connected: Input

Single-phase network monitoring Network monitoring

The connected luminaire switches on in the event of a failure of the impressed phase

or

InputIf the general lighting switch is connected, the luminaire can be swithed via said genral lighting switch.

AccESSORIES FOR LUXIFAIR AnD LUXIFAIRlight

L

B

H

L

B

H

Page 157: Emergency Lighting A1

155

EMERGEncy LIGhtInG | cEntRAL BAttERy SyStEMS

tender texts available upon request | Specifications subject to alteration

Monitoring module CONTROL1

type of protection: IP 20

Dimensions: L 106 x B 36 x h 24

Input voltage: 230 V Ac (+10% / -15%)

230 V Dc (+20% / -20%)

Ambient temperature: -5°c bis 50°c

housing: plastic, white

Module for monitoring single luminaires of 2-120 W. Luminaire addresses are set using an externally accessible rotary code switch.

CONTROL1 for RZBeasy and GV 1500 981348.002 L 106, B 36, h 24 mm

L/+

2-12 W

13-48 W

49-120 W

N/-

Inpu

t

EB

L/+

N/-

L/+ must always be connected

L/L+

N/N-

N/- depending on the performance of the luminaire or EB

Illustration below:

terminals L/L+ and n/n+ (mains side) are the connection to the emergency power unit; the poles must not be switched.

Illustration below:

control voltage for the internal switch

only is connected to terminals L and n.

terminals L/L+ and n/n+ (mains side) are the connection to the emergency power unit; the poles must not be switched.

TWIN technology

three power modes (non-maintained, maintained and switched maintained power mode) can be installed and operated within the same circuit, thus reducing the number of electric circuits.

Single luminaire monitoring module

tWIn control for installation in luminaires

Module for monitoring single luminaires of 2-120 W. Luminaire addresses are set using an externally accessible rotary code switch, with integrated changeover switch.

type of protection: IP 20

Dimensions: L 115 x B 34 x h 23

control voltage for changeover switch: 230 V Ac (+10% / -10%)

Input voltage: 230 V Ac (+10% / -15%) , 220 V Dc (+/- 20%)

Ambient temperature: -5 to + 50°c

housing: plastic, white

Suiteable for installation in systems complying with DIn VDE 0108-100 En50172. Radio interference suppression according to En55015.

TWIN-Control for RZBeasy and GV 1500 981705.002 L 115, B 34, h 23 mm

49-120W13-48W

2-12WL/+

N/-

EB

N/-

L/-

NL{

InputN/N-L/L+

An den Klemmen L und Nwird nur eine Steuerspannung

für die interne Umschaltweicheangelegt.

Die L/L+ und N/N- Klemmen(netzseitig) sind der Anschluss zur

Notstromanlage, die Polarität darf nicht vertauscht werden.

N/- depending on the performance of the luminaire or EB

L/+ must always be connected

AccESSORIES FOR GV 1500 AnD RZBeasy

H

B

L

H

L

B

Page 158: Emergency Lighting A1

156

EMERGEncy LIGhtInG | cEntRAL BAttERy SyStEMS

tender texts available upon request | Specifications subject to alteration

Remote control tableau Type: MTB-BUS

- connection via 3-core bus line

- Surface mounted version with window in the housing

- Illuminated plain text display, 4 lines, 16 characters each

- Membrane keyboard

- Battery voltage display

- charging/discharging current display

- Voltage display of all 3 supply phases

- test log display

- Luminaire error display

- Error display in plain text

- Online

- Failure

- Mains supply mode / battery mode

- Maitained on / non-maintained on

- testing mode

- Switch system on/off

- Switch maintained light on/off

- Start of functions test and capacity test

- Selection of configuration and information menu

the remote control tableau can also be used as a display unit for sub-stations.

Remote control tableau for GV 1500 985021

Bus line 2 x 2 x 0,8

nyM 1 x 3 (for 220V Dc auxiliary voltage)

Universal changeover unit Type: UUE 4/220

All four output circuits of the plug-in units can be used both for circuit-monitored systems and for single luminaire monitoring. Mixed operation of single luminaire and circuit monitoring is also possible. the monitoring function can be subsequently modified from circuit to single luminaire monitoring at any time by means of simple re-configuration, without the need to exchange the hardware.

Each plug-in unit can operate 4 output circuits, with up to 16 luminaires each. Each output circuit is protected by a 6.3 A (1.25 A) (2-pole) fuse and can be switched individually. Each circuit in the lighting circuit assembly can be individually programmed.

the integrated staircase light switch mode allows for time-controlled switching in mains and emergency mode using the lighting power supply buttons (switch-on time 1 – 15 minutes, individually adjustable for each circuit.)

Universal changeover unit, type UUE 4/220 for GV 1500 985019

Universal changeover unit, type UUE 4/220-80 for up to 80 W total for GV 1500985195

AccESSORIES FOR GV 1500

Page 159: Emergency Lighting A1

157

EMERGEncy LIGhtInG | cEntRAL BAttERy SyStEMS

tender texts available upon request | Specifications subject to alteration

Light switch setting sensor module (LSM)

this module allows for final circuit switching in mains mode using the switches or contactors of the mains power supply lighting. the input ports can interrogate a maximum of 16 circuits.

Each input can be programmed as a staircase light switch for time-controlled switching of emergency lighting (1-15 minutes).

Option:

the LSM modules can also be integrated in external distributors.

(Max. length of BUS line: 100 m).

Sensor module LSM 24

Each input can be assigned to one or several output circuits of a plug-in rack for single or group switching. Requests are transmitted via potential-free contacts.

Light switch setting sensor module LSM 24 for GV 1500 985054

Light switch setting sensor module LSM 230

Each input can be assigned to one or several output circuits of a plug-in rack for single or group switching. Requests are transmitted via an external 230 V Ac voltage.

Light switch setting sensor module LSM 230 for GV 1500 985055

Sensor module LSM 24 / 230

Each input can be assigned to one or several output circuits of a plug-in rack for single or group switching. Requests are transmitted via an external 230 V Ac voltage (8 inputs), as well as via potential-free contacts (8 inputs).

Light switch setting sensor module LSM 24/230 for GV 1500 985182

AccESSORIES FOR GV 1500

Page 160: Emergency Lighting A1

158

Page 161: Emergency Lighting A1

159

Luminaires for central emergency power supplyTenuo 160LED Halyxx® 162Ilustris 166Display 168Flat Sign Mini/Midi 170Design 172Rechteck 250 / 360 / 485 176Multivariabel 182Luminaires for sports facilities 184Standardleuchten 184Signcube 186Rechteck (Universal 2) 189Universal 3 190Universal 3 LED 191Universal 4 192Universal 4 LED 193LCS‑Z 194Varioplast I 196Turia 198Edo 200Lucio 202Centryxx 204Solyxx 206Energo TC 175 208Energo TC 210 210Andho TC Flat 212Andho TC Flat IP 65 214Arelo® 216Mondana 218Flat Polymero® 220Flat Polymero® PMMA/PC 222Flat Basic 224Flat Polymero® Rechteck 226Rounded® superflach 228Alu‑Lux oval 230Alu‑Rund 230Light Case 232Safety striplights 234Alu‑Druckguss 236Recessed LED step luminaire for installation in concrete steps 238

162, 164 162, 165 166

182 - 185 186 188, 189

172 - 174 176, 177172 - 174

216

188, 192 194 196

218

202 206204

176, 178

168

160 162 - 163

176, 179

170

198

188, 190 188, 192

208 - 210 212 - 214

200

228

236 238

230

234230

222

232

220

224 226

LED LED LED LED LED

LED

LED LED LED

LED

LED LED LED LED LED

LED LED

LED

Page 162: Emergency Lighting A1

160

EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy

Motifs for escape route identification – Building and workplace legislation Legends in accordance with DIn 4844, UVV BgV A8 and EECR 92/58 Background colour: green

Tenuo Type of protection: IP 40

- The flattest existing emergency luminaire that incorporates the very latest energy saving LED technology

- Ultraflat - (panel 5 mm) frame 8 mm

- Energy efficient (consumption approx. 60% less than 13 W fluorescent lamp technology)

- Top quality LED technology

- Specially calculated thermal management

- The very latest LED technology keeps maintenance costs to a minimum

- LED service life: approx. 50,000 hours

- Exceptionally high luminance of over 900 cd/m2

- Wide range of applications thanks to various types of installation

wall extension wall (semi‑recessed) Ceiling (surface) Ceiling (recessed) Pendant tubeSuspension cable/chain

1003

1113

1114

1004

1115

1116

1005

Page 163: Emergency Lighting A1

161

EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy

For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration

wall (surface) wall extension wall (semi‑recessed) wall (surface) Ceiling (recessed) Pendant tubeSuspension cable/chain

Installation scheme available on request

Installation scheme available on request

Installation scheme available on request

Installation scheme available on request

Installation scheme available on request

Installation scheme available on request

Installation scheme available on request

Article number Type of installation

Viewing distance

Lamp/wattage Control 1 (.71)

TwIn‑Control

(.72)

SIngLE‑Control

(.81)

DUo‑Control

(.82)

Dimensions

671923.00X.y wall (surface) 30 m 1 x LED 2,5 w • • • • L 350, B 33, H 200

671938.00X.y wall extension 30 m 1 x LED 5 w • • • • L 400, B 60, H 200

671922.00X.y wall (semi‑recessed) 30 m 1 x LED 2,5 w • • • • L 350, B 11, H 200, LA 173, BA 173, TE 70

671939.00X.y Ceiling (surface) 30 m 1 x LED 5 w • • • • L 350, B 50, H 240

671940.00X.y Ceiling (recessed) 30 m 1 x LED 5 w • • • • L 420, B 40, H 252, LA 400, BA 40, HE 90

671941.00X.y Pendant tube 30 m 1 x LED 5 w • • • • L 350, B 50, H 200, LP 500

671942.00X.y Suspension cable/chain 30 m 1 x LED 5 w • • • • L 350, B 50, H 200, LP 500

Series: Tenuo

Type of protection: IP 40 Protection class: I Voltage: 220 ‑ 240 V / 0 Hz, 50 ‑ 60 Hz Viewing distance: 30 m

For escape route identification

Housing: aluminium, silver Display panel with patented MicroLens technology.

LED included.

Please indicate symbol number when placing your order!

Ballast: EB

Available colour (X): 4 = aluminium, anodised

30 m30 m

H

L B

H

L B

HA

L TE

H

LA

B

H

L B

H

L

LAB

BA

HE

LP

L B

H

LP

L B

H

Page 164: Emergency Lighting A1

162

EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy

wall (surface) Ceiling (surface) Ceiling (recessed) wall (recessed)

Motifs for escape route identification – Building and workplace legislation Legends in accordance with DIn 4844, UVV BgV A8 and EECR 92/58 Background colour: green

LED Halyxx® Type of protection: IP 40

- High quality aluminium housing

- High quality and elegant design

- Energy efficient (consumption approx. 60% less than 13 W fluorescent lamp technology)

- Specially calculated thermal management

- The very latest LED technology keeps maintenance costs to a minimum

- LED service life: approx. 50,000 hours

- Luminance exceeds 500 cd/m2

- Wide range of applications thanks to various types of installation

- Moulded housing for concrete available

- Easy to install

1003

1113

1114

1004

1115

1116

1005

Page 165: Emergency Lighting A1

163

EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy

For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration

Mounting set for suspension cable/chainViewing distance: 14 m981701.004 L 213, B 33, H 77 for art. 671504.004.y

Moulded housingViewing distance: 14 m981685.000 L 542, B 142, H 143 for art. 671519.004.y

Pendant setsViewing distance: 14 m981639.020 for .82981639.060 for .71/.81

Wall extensionViewing distance: 14 m981581.004 L 258, B 38, H 104 for art. 671504.004.y

Article number Type of installation

Viewing distance

Lamp/wattage Control 1 (.71)

TwIn‑Control

(.72)

SIngLE‑Control

(.81)

DUo‑Control

(.82)

Dimensions

671503.00X.y wall (surface) 14 m 2 x LED 1,1 w • • • • L 233, B 40, H 180

671504.00X.y Ceiling (surface) 14 m 2 x LED 1,1 w • • • • L 233, B 40, H 180

671519.00X.y Ceiling (recessed) 14 m 2 x LED 1,1 w • • • • L 270, B 55, H 100 LA 255 x BA 42, HE 90

671547.12X.y wall (recessed) (cavity wall) 14 m 1 x LED 3,5 w ‑ ‑ ‑ ‑ L 220, B 150, H 2

LA 210 x BA 132, HE 90

671547.00X.y wall (recessed) (solid wall) 14 m 1 x LED 3,5 w ‑ ‑ ‑ ‑ L 220, B 150, H 2

LA 200 x BA 130, HE 80

Series: LED Halyxx®

Type of protection: IP 40 Protection class: I Voltage: 220 ‑ 240 V / 0 Hz, 50 ‑ 60 Hz Viewing distance: 14 m Ceiling thickness: 5‑35 mm wall thickness: 1‑30 mm

For escape route identification

Base: aluminium extrusion profile; display panel: highly transparent plastic, with motifs on one side/both sides.

LED included.

Please specify legend number when ordering!

Ballast: EB

Available colour (X): 4 = aluminium, anodised

Accessories | Pendant set for ceiling luminairesSuspension length 500 mm (other lengths upon request), white plastic canopy, chrome suspension tube, length: 480 mm, can be shortened on site.

wall (surface) Ceiling (surface) Ceiling (recessed) wall (recessed) (cavity wall) wall (recessed) (solid wall)

14 m

H

L B

H

L B

H

LLA

BBA

HE5-

35

3

180

151233

4523Ø4,5

15

15

150233

Ø5

12,550

1640

4255

255270

HA

LHE

1-30

H

LA

BL

HA

HE

LA

B

H

132150

210220

130150

200220

Page 166: Emergency Lighting A1

164

EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy

Ceiling (surface)wall (surface) Ceiling (recessed)

Mounting set for suspension cable/chainViewing distance: 19 m981701.004 L 213, B 33, H 77 for art. 671736.004.y

Moulded housingViewing distance: 19 m981686.000 L 542, B 142, H 143 for art. 671739.004.y

Pendant setsViewing distance: 19 m981639.020 for .82981639.060 for .71/.81

Wall extensionViewing distance: 19 m981581.004 L 258, B 38, H 104 for art. 671738.004.y

Article number Type of installation

Viewing distance

Lamp/wattage Control 1 (.71)

TwIn‑Control

(.72)

SIngLE‑Control

(.81)

DUo‑Control

(.82)

Dimensions

671738.00X.y wall (surface) 19 m 2 x LED 1,1 w • • • • L 235, B 40, H 220

671736.00X.y Ceiling (surface) 19 m 2 x LED 1,1 w • • • • L 235, B 40, H 220

671739.00X.y Ceiling (recessed) 19 m 2 x LED 1,1 w • • • • L 320, B 55, H 140 LA 305 x BA 42, HE 90

For connecting diagrams, see pages 119 ‑ 121 | Article number explanations: see page 276Tender texts available upon request | Specifications subject to alteration

Series: LED Halyxx®

Type of protection: IP 40 Protection class: I Voltage: 220 ‑ 240 V / 0 Hz, 50 ‑ 60 Hz Viewing distance: 19 m Ceiling thickness: 5‑35 mm

For escape route identification

Base: aluminium extrusion profile; display panel: highly transparent plastic, with motifs on one side/both sides.

LED included.

Please specify legend number when ordering!

Ballast: EB

Available colour (X): 4 = aluminium, anodised

Accessories | Pendant set for ceiling luminairesSuspension length 500 mm (other lengths upon request), white plastic canopy, chrome suspension tube, length: 480 mm, can be shortened on site.

19 m

H

L B

H

L B

H

L LA

B BA

HE

5-35

150

233Ø5

12,5

50

1640

3

220

151235

4523

Ø4,5

15

15

4255

305320

Page 167: Emergency Lighting A1

165

EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy

For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration

wall (surface) Ceiling (surface) Ceiling (recessed)

Mounting set for suspension cable/chainViewing distance: 30 m981702.004 L 318, B 33, H 57 for art. 671737.004.y

Moulded housingViewing distance: 30 m981687.000 L 542, B 142, H 143 for art. 671740.004.y

Pendant setsViewing distance: 30 m981647.000 for .71/.81981647.020 for .82

Wall extensionViewing distance: 30 m981640.000 L 363, B 38, H 104 for art. 671722.004.y

Article number Type of installation

Viewing distance

Lamp/wattage Control 1 (.71)

TwIn‑Control

(.72)

SIngLE‑Control

(.81)

DUo‑Control

(.82)

Dimensions

671722.00X.y wall (surface) 30 m 3 x LED 1,1 w • • • • L 340, B 40, H 270

671737.00X.y Ceiling (surface) 30 m 3 x LED 1,1 w • • • • L 340, B 40, H 270

671740.00X.y Ceiling (recessed) 30 m 3 x LED 1,1 w • • • • L 424, B 55, H 190 LA 410 x BA 42, HE 90

Series: LED Halyxx®

Type of protection: IP 40 Protection class: I Voltage: 220 ‑ 240 V / 0 Hz, 50 ‑ 60 Hz Viewing distance: 30 m Ceiling thickness: 5‑35 mm

For escape route identification

Base: aluminium extrusion profile; display panel: highly transparent plastic, with motifs on one side/both sides.

LED included.

Please specify legend number when ordering!

Ballast: EB

Available colour (X): 4 = aluminium, anodised

Accessories | Pendant set for ceiling luminairesSuspension length 500 mm (other lengths upon request), white plastic canopy, chrome suspension tube, length: 480 mm, can be shortened on site.

H

L B

H

L B

H

L LA

B BA

HE

5-35

30 m

3

270

250340

4523

Ø4,5

15

25

40

270340

25

Ø510,5

27,5

4255

410424

Page 168: Emergency Lighting A1

166

EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy

wall (surface) Ceiling (surface)

Ilustris Type of protection: IP 20

- Design matches modern architectural styles

- Energy efficient (consumption approx. 60% less than 13 W fluorescent lamp technology)

- The very latest LED technology keeps maintenance costs to a minimum

- LED service life: approx. 50,000 hours

- Large viewing distance

- Wide range of applications thanks to various types of installation

Page 169: Emergency Lighting A1

167

EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy

For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration

wall (surface) Ceiling (surface)

Pendant tube981777.0131 Pendant lenght 500 mm –981777.0231 Pendant length 500 mm for .82

Suspension cable/chain981776.000 Pendant lenght 1500 mm –

Wall extension981775.0031 L 300, B 150, H 35 –

Article number Type of installation

Viewing distance

Lamp/wattage Control 1 (.71)

TwIn‑Control

(.72)

SIngLE‑Control

(.81)

DUo‑Control

(.82)

Dimensions

671843.00X.y wall (surface) 30 m 1 x LED 3 w ‑ ‑ ‑ • L 368, B 55, H 253

671847.00X.y Ceiling (surface) 30 m 1 x LED 3 w ‑ ‑ ‑ • L 368, B 27, H 263

Series: Ilustris

Type of protection: IP 20 Protection class: I Voltage: 220 ‑ 240 V / 0 Hz, 50 ‑ 60 Hz Viewing distance: 30 m

For escape route identification

Housing: die‑cast aluminium, powder‑coated. 3 foils with escape route motif and 1 white foil included.

LED included.

Ballast: EB

Available colour (X): 31 = anthracite metallic 30 m

H

L B

H

L B

5,5x10

100368

26

Ø5,5

120

150

368

253

35 5522

Page 170: Emergency Lighting A1

168

EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy

Ceiling (surface)wall (surface) Ceiling (recessed)

Motifs for escape route identification – Building and workplace legislation Legends in accordance with DIn 4844, UVV BgV A8 and EECR 92/58 Background colour: green

Display Type of protection: IP 40

- Absolutely uniform illumination of the motifs

- Wide range of applications thanks to various types of installation

- Designed for large viewing distances

- Standard fluorescent lamps can be used

- Specifically calculated reflector inside the luminaire

1003

1113

1114

1004

1115

1116

1005

Page 171: Emergency Lighting A1

169

EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy

For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration

Ceiling (surface)wall (surface) Ceiling (recessed)

Wall extension981489.002

Moulded housing981586.000

Article number Type of installation

Viewing distance

Lamp/wattage Control 1 (.71)

TwIn‑Control

(.72)

SIngLE‑Control

(.81)

DUo‑Control

(.82)

Dimensions

671180.75X.y wall (surface) 32 m 1 x T16 (T5) 8 w • • • • L 332, B 70, H 236

671178.75X.y Ceiling (surface) 32 m 1 x T16 (T5) 8 w • • • • L 332, B 57, H 270

671179.75X.y Ceiling (recessed) 32 m 1 x T16 (T5) 8 w • • • • L 400, B 84, H 180 LA 380 x BA 68, HE 105

Series: Display

Type of protection: IP 40 Protection class: I Voltage: 220 ‑ 240 V / 0 Hz, 50 ‑ 60 Hz Viewing distance: 32 m Ceiling thickness: 1‑40 mm

For escape route identification

Base: powder‑coated metal; plastic display panel wit motifs on one side/both sides. EB incorporated.

Lamp included.

Please specify legend number when ordering!

Ballast: EB

Available colours (X): 2 = white, 4 = silver metallic

Accessories | Wall extensionSteel bracket, white powder‑coated

Accessories | Pendant setSuspension tube, square: 40 x 40 mm, powder‑coated, suspension length 500 mm (other lengths available upon request)

Pendant kit90‑3757.002 Pendant length 500 mm white90‑3757.004 Pendant length 500 mm silver metallic

32 m

H

L B

H

L B

H

HE1-40

L

LA BA

B

5716

9618

332276

5x8

56

236

15

332

27643 18 5x8

84

400

68

380

Page 172: Emergency Lighting A1

170

EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy

Pendant tubewall (surface)

Motifs for escape route identification – Building and workplace legislation Legends in accordance with DIn 4844, UVV BgV A8 and EECR 92/58 Background colour: green

Flat Sign Mini/Midi Type of protection: IP 43

- Exclusive luminaire design

- Energy efficient (consumption approx. 60% less than 13 W fluorescent lamp technology)

- Top quality LED technology

- Uniform light distribution provided by special LED arrangement

- 2 different housing dimensions for different viewing distances

1003

1113

1114

1004

1115

1116

1005

Page 173: Emergency Lighting A1

171

EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy

For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration

Pendant tubewall (surface) Midiwall (surface) Mini

Article number Type of installation

Viewing distance

Type Lamp/wattage Control 1 (.71)

TwIn‑Control

(.72)

SIngLE‑Control

(.81)

DUo‑Control

(.82)

Dimensions

671555.00X.y wall (surface) 21 m Mini 2 x LED 1,1 w • ‑ • • L 237, B 84, H 125

671556.00X.y wall (surface) 32 m Midi 3 x LED 1,1 w • • • • L 348, B 84, H 178

671557.00X.y Pendant tube 21 m Mini 4 x LED 1,1 w • ‑ • • L 237, B 138, H 125, LP 480

671607.00X.y Pendant tube 32 m Midi 6 x LED 1,1 w • • • • L 348, B 138, H 178, LP 480

Series: Flat Sign Mini/Midi

Type of protection: IP 43 Protection class: I Voltage: 220 ‑ 240 V / 0 Hz, 50 ‑ 60 Hz Viewing distance: 21 m, 32 m

For escape route identification

Housing: powder‑coated sheet steel; display panel: plastic, opal, with motifs on one side/both sides.

LED included.

Please specify legend number when ordering!

Ballast: EB

Available colour (X): 2 = white

21 m/32 m

LP

L B

H

H

L B

H

L B

60

10

Ø10

Ø3,530

237

27

348

Ø20

9x5178

120

27

237

Ø20

9x5125

8

Page 174: Emergency Lighting A1

172

EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy

wall extension Ceiling (surface) Pendant tubewall (surface), Ceiling (surface) wall (surface)

Motifs for escape route identification – Building and workplace legislation Legends in accordance with DIn 4844, UVV BgV A8 and EECR 92/58 Background colour: green

Design Type of protection: IP 40

- Flat aluminium housing in elegant design

- Installation-friendly design enables lamp replacement without tools

- Designed for large viewing distances

- Wide range of applications thanks to various types of installation

- Luminaire also available for escape route illumination

1003

1113

1114

1004

1115

1116

1005

Page 175: Emergency Lighting A1

173

EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy

For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration

wall (surface) wall extension Pendant tubeCeiling (surface)

Article number Type of installation

Viewing distance

Lamp/wattage Control 1 (.71)

TwIn‑Control

(.72)

SIngLE‑Control

(.81)

DUo‑Control

(.82)

Dimensions

671597.75X.y wall (surface) 26 m 1 x T16 (T5) 6 w • • • • L 294, B 55, H 190

671599.75X.y wall extension 26 m 1 x T16 (T5) 6 w • • • • L 314, B 55, H 190

671598.75X.y Ceiling (surface) 26 m 1 x T16 (T5) 6 w • • • • L 340, B 55, H 232

671600.75X.y Pendant tube 26 m 1 x T16 (T5) 6 w • • • • L 340, B 55, H 190, LP 524

Series: Design

Type of protection: IP 40 Protection class: I Voltage: 220 ‑ 240 V / 0 Hz, 50 ‑ 60 Hz Viewing distance: 26 m

For escape route identification

Housing: aluminium, powder‑coated; plastic panel: opal, with motifs on one side/on two sides. EB incorporated.

Please indicate symbol number when placing your order!

Ballast: EB

Available colour (X): 2 = white

Accessories | Wire guardBall impact proof in accordance with DIn 18032, Part 3 and DIn VDE 0710, Part 13

wire guard and bracket: steel, white, powder‑coated. wire guard mounted with screws, can be opened for luminaire maintenance.

Wire guard for wall luminaires981167.002 L 380, B 295, H 185

26 m

H

L B

H

B L

90

15

210

294

190

27

19075

55

18

5,5x10

LP

H

L B

H190

L B

6 6340

8260

82Ø6

5542

52,5 52,5

340169,5

5x12

Page 176: Emergency Lighting A1

174

EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy

Wire guard for wall luminaires981168.002 L 540, B 375, H 185

wall (surface) wall extension Pendant tubeCeiling (surface)

Article number Type of installation

Viewing distance

Lamp/wattage Control 1 (.71)

TwIn‑Control

(.72)

SIngLE‑Control

(.81)

DUo‑Control

(.82)

Dimensions

671185.75X.y wall (surface) 33 m 1 x T16 (T5) 8 w • • • • L 370, B 55, H 228

671188.75X.y wall extension 33 m 1 x T16 (T5) 8 w • • • • L 390, B 55, H 228

671186.75X.y Ceiling (surface) 33 m 1 x T16 (T5) 8 w • • • • L 416, B 55, H 270

671312.75X.y Pendant tube 33 m 1 x T16 (T5) 8 w • • • • L 416, B 55, H 228, LP 500

For connecting diagrams, see pages 119 ‑ 121 | Article number explanations: see page 276Tender texts available upon request | Specifications subject to alteration

Series: Design

Type of protection: IP 40 Protection class: I Voltage: 220 ‑ 240 V / 0 Hz, 50 ‑ 60 Hz Viewing distance: 33 m

For escape route identification

Housing: aluminium, powder‑coated; plastic panel: opal, with motifs on one side/on two sides. EB incorporated.

Please indicate symbol number when placing your order!

Ballast: EB

Available colour (X): 2 = white

Accessories | Wire guardBall impact proof in accordance with DIn 18032, Part 3 and DIn VDE 0710, Part 13

wire guard and bracket: steel, white, powder‑coated. wire guard mounted with screws, can be opened for luminaire maintenance.

33 m

H

L B

H

B L

LP

H

L B

H228

L B

117 22847

283

28370

6x16

22890

55

5x10

18

6 6416

8260

82Ø6

5542

53 53

416208

5x12

Page 177: Emergency Lighting A1

175

EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy

For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration

Wire guard for wall luminaires981168.002 L 540, B 375, H 185

Spacing table 671181.752

Lamp luminous flux:

Mains: 450 lm, Emergency: 450 lm

The following values are indicated in m

h a b c d

2.5 8.4 3.5 10.6 4.6

3.0 8.7 3.8 11.8 4.9

3.5 9.7 3.9 12.6 5.1

4.0 10.0 4.0 13.5 5.3

Spacing table 671182.752

Lamp luminous flux:

Mains: 1350 lm, Emergency: 1350 lm

The following values are indicated in m

h a b c d

2.5 10.6 4.7 15.0 6.3

3.0 12.2 5.2 15.8 6.8

3.5 12.5 5.5 16.9 7.3

4.0 14.0 5.9 18.4 7.7

Spacing table 671183.752

Lamp luminous flux:

Mains: 3350 lm, Emergency: 3350 lm

The following values are indicated in m

h a b c d

2.5 13.2 5.8 18.0 8.0

3.0 14.4 6.5 20.4 8.8

3.5 15.9 7.0 21.9 9.4

4.0 16.9 7.5 22.4 10.0

Spacing table 671184.752

Lamp luminous flux:

Mains: 5400 lm, Emergency: 5400 lm

The following values are indicated in m

h a b c d

2.5 14.8 6.4 21.5 9.0

3.0 16.1 7.1 22.5 9.9

3.5 17.6 7.8 24.6 10.7

4.0 18.5 8.5 27.0 11.4

Article number Type of installation

Viewing distance

Lamp/wattage Control 1 (.71)

TwIn‑Control

(.72)

SIngLE‑Control

(.81)

DUo‑Control

(.82)

Dimensions

671181.75X.y wall (surface), Ceiling (surface) ‑ 1 x T16 (T5) 8 w • • • • L 370, B 228, H 55

671182.75X.y wall (surface), Ceiling (surface) ‑ 1 x T26 (T8) 18 w • • • • L 695, B 228, H 55

671183.75X.y wall (surface), Ceiling (surface) ‑ 1 x T26 (T8) 36 w • • • • L 1305, B 228, H 55

671184.75X.y wall (surface), Ceiling (surface) ‑ 1 x T26 (T8) 58 w • • • • L 1605, B 228, H 55

Series: Design

Type of protection: IP 40 Protection class: I Voltage: 220 ‑ 240 V / 0 Hz, 50 ‑ 60 Hz

For escape route illumination

Housing: aluminium, powder‑coated; plastic panel: transparent, prismatic inside; reflector: aluminium, highly polished anodised finish, wide beam. EB incorporated.

Ballast: LLB/EB

Available colour (X): 2 = white

Accessories | Wire guardBall impact proof in accordance with DIn 18032, Part 3 and DIn VDE 0710, Part 13

wire guard and bracket: steel, white, powder‑coated. wire guard mounted with screws, can be opened for luminaire maintenance.

wall (surface), Ceiling (surface) 8 w wall (surface), Ceiling (surface) 18 w wall (surface), Ceiling (surface) 36 w wall (surface), Ceiling (surface) 58 w

Planning guide: Escape route illumination in accordance with EN 1838

E = 1 lx along the centre line

L B

H

L B

H

L B

H

L B

H

117 22864

4444

370

6x16

117 22864

317 4444

1305

6x16

117 22864

313 4444

1605

6x16

120 22852

615

35695

6x16

h

d c b

a

Page 178: Emergency Lighting A1

176

EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy

Ceiling (surface) Suspension cable/chainPendant tubewall (surface) wall extension

Motifs for escape route identification – Building and workplace legislation Legends in accordance with DIn 4844, UVV BgV A8 and EECR 92/58 Background colour: green

Rechteck 250 / 360 / 485 Type of protection: IP 44

- High quality aluminium profile housing

- Installation-friendly conctruction facilitates easy lamp replacement

- Wide range of applications thanks to various types of installation

- Quick and easy to install thanks to the use of a quick-action locking mechanism for the lamp and ballast support

- Available also with exceptionally long service life and energy efficient LED technology

- LED conversion sets are available for existing luminaires

1003

1113

1114

1004

1115

1116

1005

Page 179: Emergency Lighting A1

177

EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy

For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration

Article number Type of installation

Viewing distance

Lamp/wattage Control 1 (.71)

TwIn‑Control

(.72)

SIngLE‑Control

(.81)

DUo‑Control

(.82)

Dimensions

671207.00X.y wall (surface) 21 m 2 x LED 1,1 w • • • • L 250, B 90, H 140

671207.75X.y wall (surface) 21 m 1 x T16 (T5) 6 w • • • • L 250, B 90, H 140

671256.00X.y wall (surface) 21 m 2 x Co26 15 w ‑ ‑ ‑ ‑ L 250, B 90, H 140

671208.00X.y wall extension 21 m 4 x LED 1,1 w • • • • L 250, B 125, H 140

671209.75X.y wall extension 21 m 1 x T16 (T5) 6 w • • • • L 250, B 125, H 140

671258.00X.y wall extension 21 m 1 x E27 25 w ‑ ‑ ‑ ‑ L 250, B 125, H 140

671211.00X.y Ceiling (surface) 21 m 4 x LED 1,1 w • • • • L 250, B 125, H 140

671211.75X.y Ceiling (surface) 21 m 1 x T16 (T5) 6 w • • • • L 250, B 125, H 140

671260.00X.y Ceiling (surface) 21 m 1 x E27 25 w ‑ ‑ ‑ ‑ L 250, B 125, H 140

671213.00X.y Pendant tube 21 m 4 x LED 1,1 w • • • • L 250, B 125, H 140, LP 500

671213.75X.y Pendant tube 21 m 1 x T16 (T5) 6 w • • • • L 250, B 125, H 140, LP 500

671262.00X.y Pendant tube 21 m 1 x E27 25 w ‑ ‑ ‑ ‑ L 250, B 125, H 140, LP 500

671359.00X.y Suspension cable/chain 21 m 4 x LED 1,1 w • • • • L 250, B 125, H 140

671359.75X.y Suspension cable/chain 21 m 1 x T16 (T5) 6 w • • • • L 250, B 125, H 140

671357.00X.y Suspension cable/chain 21 m 1 x E27 25 w ‑ ‑ ‑ ‑ L 250, B 125, H 140

Ceiling (surface)wall (surface) Pendant tube Suspension cable/chainwall extension

Series: Rechteck 250

Type of protection: IP 44 Protection class: I Voltage: 220 ‑ 240 V / 0 Hz, 50 ‑ 60 Hz Viewing distance: 21 m

For escape route identification

Housing: aluminium, with plastic corner connectors. Display panels: plastic, opal, with motif on one side/on both sides.

Lamp included.

Please specify legend number when ordering!

Ballast: EB

Available colours (X): 2 = white, 4 = aluminium, anodised

Accessories | Wire guardBall impact proof in accordance with DIn 18032, Part 3 and DIn VDE 0710, Part 13

wire guard and bracket: steel, white, powder‑coated. wire guard mounted with screws, can be opened for luminaire maintenance.

Wire guard for wall luminaires981167.002 L 380, B 295, H 185

21 m

H

40

BL

40 80

H

L B

LP

H

BL

40 40

40

H

L B

30

80

LB

4080

H

40

3340

140

250

6x1640

40

41

41

18140 80

12580

6x12 5555250

40 1212

80 68 12511

9

Ø 5 6x18 Ø 6

125

70 4x10

85250

60 125

250

50 5030

Page 180: Emergency Lighting A1

178

EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy

Wire guard for wall luminaires981168.002 L 540, B 375, H 185

Article number Type of installation

Viewing distance

Lamp/wattage Control 1 (.71)

TwIn‑Control

(.72)

SIngLE‑Control

(.81)

DUo‑Control

(.82)

Dimensions

671215.00X.y wall (surface) 32 m 3 x LED 1,1 w • • • • L 362, B 90, H 192

671215.75X.y wall (surface) 32 m 1 x T16 (T5) 8 w • • • • L 362, B 90, H 192

671264.00X.y wall (surface) 32 m 2 x IT‑3 30 25 w ‑ ‑ ‑ ‑ L 362, B 90, H 192

671217.00X.y wall extension 32 m 6 x LED 1,1 w • • • • L 362, B 125, H 192

671217.75X.y wall extension 32 m 1 x T16 (T5) 8 w • • • • L 362, B 125, H 192

671266.00X.y wall extension 32 m 2 x E27 25 w ‑ ‑ ‑ ‑ L 362, B 125, H 192

671223.00X.y Ceiling (surface) 32 m 6 x LED 1,1 w • • • • L 362, B 125, H 192

671223.75X.y Ceiling (surface) 32 m 1 x T16 (T5) 8 w • • • • L 362, B 125, H 192

671268.00X.y Ceiling (surface) 32 m 2 x E27 25 w ‑ ‑ ‑ ‑ L 362, B 125, H 192

671227.00X.y Pendant tube 32 m 6 x LED 1,1 w • • • • L 362, B 125, H 192, LP 500

671227.75X.y Pendant tube 32 m 1 x T16 (T5) 8 w • • • • L 362, B 125, H 192, LP 500

671270.00X.y Pendant tube 32 m 2 x E27 25 w ‑ ‑ ‑ ‑ L 362, B 125, H 192, LP 500

671363.00X.y Suspension cable/chain 32 m 6 x LED 1,1 w • • • • L 362, B 125, H 192

671363.75X.y Suspension cable/chain 32 m 1 x T16 (T5) 8 w • • • • L 362, B 125, H 192

671361.00X.y Suspension cable/chain 32 m 2 x E27 25 w ‑ ‑ ‑ ‑ L 362, B 125, H 192

wall (surface) Ceiling (surface) Pendant tube Suspension cable/chainwall extension

For connecting diagrams, see pages 119 ‑ 121 | Article number explanations: see page 276Tender texts available upon request | Specifications subject to alteration

Series: Rechteck 360

Type of protection: IP 44 Protection class: I Voltage: 220 ‑ 240 V / 0 Hz, 50 ‑ 60 Hz Viewing distance: 32 m

For escape route identification

Housing: aluminium, with plastic corner connectors. Display panels: plastic, opal, with motif on one side/on both sides.

Lamp included.

Please specify legend number when ordering!

Ballast: EB

Available colours (X): 2 = white, 4 = aluminium, anodised

Accessories | Wire guardBall impact proof in accordance with DIn 18032, Part 3 and DIn VDE 0710, Part 13

wire guard and bracket: steel, white, powder‑coated. wire guard mounted with screws, can be opened for luminaire maintenance.

32 m

40

3340

192

362

6x1640

40

55

55

192

40

12

12

8068

125119

Ø 5

6x18

Ø 6

5555362

40 1212

80 68 12511

9

Ø 5 6x18 Ø 6

125

70 4x10

85362

60 125

362

50 5030

H

L B

H

40

BL

40 80

LP

H

BL

40 40

40

H

L B

30

40

LB

4080

H

Page 181: Emergency Lighting A1

179

EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy

For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration

Article number Type of installation

Viewing distance

Lamp/wattage Control 1 (.71)

TwIn‑Control

(.72)

SIngLE‑Control

(.81)

DUo‑Control

(.82)

Dimensions

671229.00X.y wall (surface) 43 m 4 x LED 1,1 w • • • • L 485, B 90, H 250

671229.75X.y wall (surface) 43 m 1 x T26 (T8) 15 w • • • • L 485, B 90, H 250

671272.00X.y wall (surface) 43 m 2 x IT‑3 30 40 w ‑ ‑ ‑ ‑ L 485, B 90, H 250

671231.00X.y wall extension 43 m 8 x LED 1,1 w • • • • L 485, B 125, H 250

671231.75X.y wall extension 43 m 1 x T26 (T8) 15 w • • • • L 485, B 125, H 250

671274.00X.y wall extension 43 m 2 x E27 40 w ‑ ‑ ‑ ‑ L 485, B 125, H 250

671233.00X.y Ceiling (surface) 43 m 8 x LED 1,1 w • • • • L 485, B 125, H 250

671233.75X.y Ceiling (surface) 43 m 1 x T26 (T8) 15 w • • • • L 485, B 125, H 250

671276.00X.y Ceiling (surface) 43 m 2 x E27 40 w ‑ ‑ ‑ ‑ L 485, B 125, H 250

671235.00X.y Pendant tube 43 m 8 x LED 1,1 w • • • • L 485, B 125, H 250, LP 500

671235.75X.y Pendant tube 43 m 1 x T26 (T8) 15 w • • • • L 485, B 125, H 250, LP 500

671278.00X.y Pendant tube 43 m 2 x E27 40 w ‑ ‑ ‑ ‑ L 485, B 125, H 250, LP 500

671367.00X.y Suspension cable/chain 43 m 8 x LED 1,1 w • • • • L 485, B 125, H 250

671367.75X.y Suspension cable/chain 43 m 1 x T26 (T8) 15 w • • • • L 485, B 125, H 250

671365.00X.y Suspension cable/chain 43 m 2 x E27 40 w ‑ ‑ ‑ ‑ L 485, B 125, H 250

Ceiling (surface) Suspension cable/chainPendant tubewall (surface) wall extension

Series: Rechteck 485

Type of protection: IP 44 Protection class: I Voltage: 220 ‑ 240 V / 0 Hz, 50 ‑ 60 Hz Viewing distance: 43 m

For escape route identification

Housing: aluminium, with plastic corner connectors. Display panels: plastic, opal, with motif on one side/on both sides.

Lamp included.

Please specify legend number when ordering!

Ballast: EB

Available colours (X): 2 = white, 4 = aluminium, anodised

43 m

H

40

BL

40 80

40

H

L B

30

LP

H

L B

40 40

H

L B

40

LB

4080

H

5555485

40 1212

80 68 12511

9

Ø 5 6x18 Ø 6

125

485

50 5030

125

4x10

4855050

70 85

60

40

3340

250

485

6x1640

40

55

55

250

40

12

12

8068

125119

Ø 5

6x18

Ø 6

Page 182: Emergency Lighting A1

180

EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy

Sets for converting luminaires of series „Rechteck 250“ for LED lamps 981722.002 single sided 2 x LED 1,1 w981722.002.81 single sided 2 x LED 1,1 w981722.002.82 single sided 2 x LED 1,1 w981722.002.71 single sided 2 x LED 1,1 w981722.002.72 single sided 2 x LED 1,1 w981723.002 double sided 4 x LED 1,1 w981723.002.71 double sided 4 x LED 1,1 w981723.002.72 double sided 4 x LED 1,1 w981723.002.81 double sided 4 x LED 1,1 w981723.002.82 double sided 4 x LED 1,1 w

Sets for converting luminaires of series „Rechteck 360“ for LED lamps 981725.002 single sided 3 x LED 1,1 w981725.002.71 single sided 3 x LED 1,1 w981725.002.72 single sided 3 x LED 1,1 w981725.002.81 single sided 3 x LED 1,1 w981725.002.82 single sided 3 x LED 1,1 w981727.002 double sided 6 x LED 1,1 w981727.002.71 double sided 6 x LED 1,1 w981727.002.72 double sided 6 x LED 1,1 w981727.002.81 double sided 6 x LED 1,1 w981727.002.82 double sided 6 x LED 1,1 w

Sets for converting luminaires of series „Rechteck 485“ for LED lamps 981759.002 single sided 4 x LED 1,1 w981759.002.71 single sided 4 x LED 1,1 w981759.002.72 single sided 4 x LED 1,1 w981759.002.81 single sided 4 x LED 1,1 w981759.002.82 single sided 4 x LED 1,1 w981760.002 double sided 8 x LED 1,1 w981760.002.71 double sided 8 x LED 1,1 w981760.002.72 double sided 8 x LED 1,1 w981760.002.81 double sided 8 x LED 1,1 w981760.002.82 double sided 8 x LED 1,1 w

Accessories | Sets for converting luminaires for LED lampsProtection class: I Low‑cost conversion of rectangular luminaires with T16 6 w or common incandescent lamps into luminaires with energy‑efficient, long‑life LEDs. The conversion set can be clicked in any existing housing without needing to use any tool and can be connected to the existing power supply cable.Modules’ plate: powder‑coated aluminium sheet, ballasts and connecting terminal included.

you can start right now to convert existing emergency luminaires of series Rechteck 250, 360 and 485 from incandescent or fluorescent lamp versions to LED versions.

HOW?

It‘s quite simple and easy: just use our LED conversion kits for luminaires for central emergency power supply.

Very easy „press and clip“ mounting. The conversion kit can be inserted in any existing luminaire housing without needing any tool noR screws:

For connecting diagrams, see pages 119 ‑ 121 | Article number explanations: see page 276Tender texts available upon request | Specifications subject to alteration

It’s so easy to save money

LED conversion kits

... press them together and ... ... click them into the luminaire housing.Just take the metal brackets ...

Page 183: Emergency Lighting A1

181

EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy

For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration

LED 4 w

33.29 €

T168 w

232.01 €

The correct arrangement of the LEDs was calculated by our photometry lab, which allows us to minimize the number of LEDs, without impairing the required luminance values laid down in DIn 4844, Part 1 (luminance of more than 500cd/m2 for the contrast colour).

Thanks to a clever heat management, we are able to drastically reduce heat stress fort he LEDs, preventing thus an early LED failure.

Average LED service life: approx. 50,000 hours!

Energy efficiency and costs

= costs for power supply

= costs for lamps

= lamp replacement costs

Costs comparison over a period of 5 years

Rechteck 360 in maintained mode (24h/day) LED Fluorescent lamp Incandescent lamp

Lamp wattage 4 w 8 w 2 x 25 w

Service life in hours 50,000 h 3,000 h 1,000 h

Total consumption in 1 year (8,760 h) in kwh 35.04 kwh 70.08 kwh 438.00 kwh

Power supply costs in 1 year (at 0.19 €/kwh) 6.66 € 13.32 € 83.22 €

Total consumption in 5 years (43,800 h) in kwh 175.20 kwh 350.40 kwh 2,190.00 kwh

Power supply costs in 5 years (at 0.19 €/kWh) 33.29 € 66.58 € 416.10 €

number of lamps needed in 5 years (43,800 h) 0 14 43

Costs for lamps in 5 years 0.00 € 107.10 € 118.68 €

Average time needed for replacing a lamp (minutes) 15 min. 10 min. 10 min.

Costs for replacing lamps (caretaker 25.00 €/h) 0.00 € 58.33 € 179.17 €

Total costs in 5 years (power supply, lamps, lamp replacement) 33.29 € 232.01 € 713.95 €

Incandescent lamps 2 x 25 w713.95 €

Page 184: Emergency Lighting A1

182

EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy

wall (surface), Ceiling (surface) Pendant tube

Spacing table 671373.752

Lamp luminous flux:

Mains: 300 lm, Emergency: 300 lm

The following values are indicated in m

h a b c d

2.5 5.7 2.4 8.4 3.1

3.0 6.3 2.3 8.2 3.1

3.5 5.9 2.2 7.7 2.9

4.0 6.5 1.9 8.0 2.6

Spacing table 671374.912

Lamp luminous flux:

Mains: 600 lm, Emergency: 600 lm

The following values are indicated in m

h a b c d

2.5 8.3 3.2 10.0 4.2

3.0 8.6 3.4 11.2 4.3

3.5 9.1 3.4 11.8 4.4

4.0 8.4 3.4 11.1 4.4

Spacing table 671376.752

Lamp luminous flux:

Mains: 450 lm, Emergency: 450 lm

The following values are indicated in m

h a b c d

2.5 7.2 2.9 9.3 3.8

3.0 7.9 2.9 10.2 3.8

3.5 7.4 2.9 9.7 3.8

4.0 7.2 2.8 10.6 3.6

Spacing table 671377.912

Lamp luminous flux:

Mains: 900 lm, Emergency: 900 lm

The following values are indicated in m

h a b c d

2.5 9.1 3.8 12.2 5.0

3.0 10.0 4.0 12.1 5.2

3.5 9.6 4.1 13.1 5.3

4.0 9.9 4.2 13.7 5.4

Multivariabel Type of protection: IP 54

- Industrial Design

- IP 54 type of protection - dustproof and protected against water spray

- Quick and easy to install thanks to the use of a quick-action locking mechanism for the lamp and ballast support

- Different types of installation for one sole luminaire

- Lamp replacement without tools

- Easy to install

Planning guide: Escape route illumination in accordance with EN 1838

E = 1 lx along the centre line

h

d c b

a

Page 185: Emergency Lighting A1

183

EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy

For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration

wall (surface), Ceiling (surface) Pendant tube

Wire guard for wall luminaires981167.002 L 380, B 295, H 185 for L 275981168.002 L 540, B 375, H 185 for L 370

Article number Type of installation

Viewing distance

Lamp/wattage Control 1 (.71)

TwIn‑Control

(.72)

SIngLE‑Control

(.81)

DUo‑Control

(.82)

Dimensions

671374.91X.y wall (surface), Ceiling (surface) 22 m 1 x TC‑EL 9 w • • • • L 275, B 130, H 130

671377.91X.y wall (surface), Ceiling (surface) 22 m 1 x TC‑EL 11 w • • • • L 370, B 130, H 130

671373.75X.y wall (surface), Ceiling (surface) 22 m 1 x T16 (T5) 6 w • • • • L 275, B 130, H 130

671376.75X.y wall (surface), Ceiling (surface) 22 m 1 x T16 (T5) 8 w • • • • L 370, B 130, H 130

671372.00X.y wall (surface), Ceiling (surface) 22 m 2 x E14 25 w ‑ ‑ ‑ ‑ L 275, B 130, H 130

671375.00X.y wall (surface), Ceiling (surface) 22 m 2 x E14 25 w ‑ ‑ ‑ ‑ L 370, B 130, H 130

671380.91X.y Pendant tube 22 m 1 x TC‑EL 9 w • • • • L 275, B 130, H 130, LP 500

671383.91X.y Pendant tube 22 m 1 x TC‑EL 11 w • • • • L 370, B 130, H 130, LP 500

671379.75X.y Pendant tube 22 m 1 x T16 (T5) 6 w • • • • L 275, B 130, H 130, LP 500

671382.75X.y Pendant tube 22 m 1 x T16 (T5) 8 w • • • • L 370, B 130, H 130, LP 500

671378.00X.y Pendant tube 22 m 2 x E14 25 w ‑ ‑ ‑ ‑ L 275, B 130, H 130, LP 500

671381.00X.y Pendant tube 22 m 2 x E14 25 w ‑ ‑ ‑ ‑ L 370, B 130, H 130, LP 500

Series: Multivariabel

Type of protection: IP 54 Protection class: I Voltage: 220 ‑ 240 V / 0 Hz, 50 ‑ 60 Hz Viewing distance: 22 m

For escape route identification or escape route illumination

Base: aluminium, powder‑coated. Canopy: white. Pendant tube: chrome. Diffuser: plastic, opal, 3 foils for escape route identification included.

Ballast: EB

Available colour (X): 2 = white

Accessories | Wire guardBall impact proof in accordance with DIn 18032, Part 3 and DIn VDE 0710, Part 13

wire guard and bracket: steel, white, powder‑coated. wire guard mounted with screws, can be opened for luminaire maintenance.

22 m

H

L B H

LP

L B

130

370

Ø6

40 4030 30

4520

50

80

4x14

Page 186: Emergency Lighting A1

184

EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy

wall (recessed) wall (surface), Ceiling (surface) Pendant tube

Spacing table 671236.912

Lamp luminous flux:

Mains: 600 lm, Emergency: 600 lm

The following values are indicated in m

h a b c d

2.5 7.5 3.2 10.1 4.2

3.0 8.6 3.4 11.2 4.4

3.5 8.7 3.4 11.5 4.4

4.0 8.5 3.3 11.2 4.4

Spacing table 671237.912

Lamp luminous flux:

Mains: 600 lm, Emergency: 600 lm

The following values are indicated in m

h a b c d

2.5 7.5 3.2 10.1 4.2

3.0 8.6 3.4 11.2 4.4

3.5 8.7 3.4 11.5 4.4

4.0 8.5 3.3 11.2 4.4

Luminaires for sports facilities Type of protection: IP 30

- Compact design

- Available also as ball impact proof version

- Different types of installation for one sole luminaire

- Installation-friendly construction

- Industrial design

- Easy lamp replacement

Planning guide: Escape route illumination in accordance with EN 1838

E = 1 lx along the centre line

h

d c b

a

Page 187: Emergency Lighting A1

185

EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy

For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration

wall (recessed) (solid wall) wall (surface), Ceiling (surface) wall (recessed) (cavity wall) Pendant tube

Article number Type of installation

Viewing distance

ball impact proof

Lamp/wattage Control 1 (.71)

TwIn‑Control

(.72)

SIngLE‑Control

(.81)

DUo‑Control

(.82)

Dimensions

671308.00X.y wall (recessed) (cavity wall) 14 m ‑ 1 x E14,

IT‑2 20 25 w ‑ ‑ ‑ ‑ L 230, B 75, H 5 LA 220 x BA 66, HE 65

671286.00X.y wall (recessed) (solid wall) 14 m ‑ 1 x E14,

IT‑2 20 25 w ‑ ‑ ‑ ‑ L 230, B 75, H 5 LA 220 x BA 66, HE 65

671288.00X.y wall (recessed) (solid wall) 14 m • 1 x E14,

IT‑2 20 25 w ‑ ‑ ‑ ‑ L 230, B 75, H 5 LA 220 x BA 66, HE 65

671309.91X.y wall (recessed) (cavity wall) 14 m ‑ 1 x TC‑EL 9 w • ‑ • • L 230, B 75, H 5

LA 220 x BA 66, HE 65

671287.91X.y wall (recessed) (solid wall) 14 m ‑ 1 x TC‑EL 9 w • ‑ • • L 230, B 75, H 5

LA 220 x BA 66, HE 65

671289.91X.y wall (recessed) (solid wall) 14 m • 1 x TC‑EL 9 w • ‑ • • L 230, B 75, H 5

LA 220 x BA 66, HE 65

671283.00X.y wall (surface), Ceiling (surface) 14 m ‑ 1 x E14,

IT‑2 20 25 w ‑ ‑ ‑ ‑ L 230, B 75, H 76

671284.00X.y wall (surface), Ceiling (surface) 14 m ‑ 1 x E14,

IT‑2 20 25 w ‑ ‑ ‑ ‑ L 230, B 75, H 76

671236.91X.y wall (surface), Ceiling (surface) 14 m ‑ 1 x TC‑EL 9 w • ‑ • • L 230, B 75, H 76

671237.91X.y wall (surface), Ceiling (surface) 14 m • 1 x TC‑EL 9 w • ‑ • • L 230, B 75, H 76

671285.00X.y Pendant tube 14 m ‑ 1 x E14, IT‑2 20 25 w ‑ ‑ ‑ ‑ L 230, B 75, H 76, LP 500

671238.91X.y Pendant tube 14 m ‑ 1 x TC‑EL 9 w • ‑ • • L 230, B 75, H 76, LP 500

Series: Luminaires for sports facilities

Type of protection: IP 30 Protection class: I Voltage: 220 ‑ 240 V / 0 Hz, 50 ‑ 60 Hz Viewing distance: 14 m

For escape route identification or escape route illumination

Base: galvanised sheet steel; diffuser: plastic, opal, 3 foils for escape route identification included. Version with TC‑EL‑Lp: EB incorporated

Ballast: EB

Available colour (X): 2 = white 14 m

B

HE

BA

L

LA

H

B

HE

BA

L

LA

H

H

L B

14

1466

31

65

75

230

220

max. 30

14

1466

31

65

75

90182

230

220

40

Ø575

183

23086

5x1520

LP

BL

H

75

230

60

Page 188: Emergency Lighting A1

186

EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy

Signcube Type of protection: IP 40

- Motifs on four sides

- Plastic cube (PMMA)

- For large viewing distances

- Wide range of applications thanks to various types of installation

- Excellent light distribution on the cube‘s surface

- Suspension can be shortened on side

- Easy to install

- Available with high quality LED technology

wall (surface), Ceiling (surface) Pendant tube Suspension cable/chain

Special motifs in accordance with BgV A8

Page 189: Emergency Lighting A1

187

EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy

For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration

wall (surface), Ceiling (surface) Pendant tube

Article number Type of installation

Viewing distance

Lamp/wattage Control 1 (.71)

TwIn‑Control

(.72)

SIngLE‑Control

(.81)

DUo‑Control

(.82)

Dimensions

671601.00X.y wall (surface), Ceiling (surface) 24 m 8 x LED 1,1 w • • • • L 255, B 255, H 276

671601.92X.y wall (surface), Ceiling (surface) 24 m 1 x TC‑DEL 13 w • • • • L 255, B 255, H 276

671826.00X.y Pendant tube 24 m 8 x LED 1,1 w • • • • L 255, B 255, H 291, LP 510

671602.92X.y Pendant tube 24 m 1 x TC‑DEL 13 w • • • • L 255, B 255, H 291, LP 510

671822.00X.y Suspension cable/chain 24 m 8 x LED 1,1 w • • • • L 255, B 255, H 300

671612.92X.y Suspension cable/chain 24 m 1 x TC‑DEL 13 w • • • • L 255, B 255, H 300

Suspension cable/chain

Series: Signcube

Type of protection: IP 40 Protection class: I Voltage: 220 ‑ 240 V / 0 Hz, 50 ‑ 60 Hz Viewing distance: 24 m

For escape route identification

Base: powder‑coated metal; canopy: plastic, white; pendant tube: metal, chrome (can be shortened on site); diffuser: plastic (PMMA), opal; 3 motif foils for escape route identification included (according to DIn 4844, UVV gBV A8 and EwgR 92/58), EB incorporated.

Ballast: EB

Available colour (X): 2 = white

Replacement foils991116 Motif foil 240 x 240 Motif 2003991117 Motif foil 240 x 240 Motif 2004991118 Motif foil 240 x 240 Motif 2005

Accessories | Legend foils in accordance with UVV BGV A8 and EECR 92/58Viewing distance 48 m

24 m

B

L

H

LP

L

Ø108

B

H

190

38

190

255

255

27

Ø4,5x9

60

10

Ø10

Ø3,530

B

L

H

110

38

107

255

255

28

2003 2004 2005

Page 190: Emergency Lighting A1

188

EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy

wall (surface) Rechteck (Universal 2)

Rechteck (Universal 2) Type of protection: IP 44

- All-plastic luminaire, shockproof

- Classic design

- Installation benefits in case of protection class II

- 3 foils for escape route identification included

- Low-cost installation

Universal 3 / Universal 4 Type of protection: IP 54

- All-plastic luminaire, shockproof

- IP 54 type of protection - dustproof and protected against water spray

- Can be used for all types of installation (with accessories)

- Low power consumption

- 3 foils for escape route identification included

- Low-cost installation

Universal 3 LED / Universal 4 LED Type of protection: IP 54

- All-plastic luminaire, shockproof

- IP 54 type of protection - dustproof and protected against water spray

- Can be used for all types of installation (with accessories)

- Reliable and long-lasting LED technology

- Energy efficient (consumption approx. 60% less than 13 W fluorescent lamp technology)

- LED service life: approx. 50,000 hours

- 3 foils for escape route identification included

- Low-cost installation

wall (surface), Ceiling (surface) Universal 3 / Universal 3 LED

wall (surface), Ceiling (surface) Universal 4 / Universal 4 LED

wall (surface) Universal 4 / Universal 4 LED

Page 191: Emergency Lighting A1

189

EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy

For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration

wall (surface)

Spacing table 671253.00X

Lamp luminous flux:

Mains: 400 lm, Emergency: 400 lm

The following values are indicated in m

h a b c d

2.5 6.1 1.9 6.2 3.6

3.0 5.2 1.5 6.8 3.5

3.5 4.9 0.6 6.5 3.3

4.0 ‑ ‑ ‑ ‑

Spacing table 671254.91X

Lamp luminous flux:

Mains: 400 lm, Emergency: 400 lm

The following values are indicated in m

h a b c d

2.5 6.1 1.9 6.2 3.6

3.0 5.2 1.5 6.8 3.5

3.5 4.9 0.6 6.5 3.3

4.0 ‑ ‑ ‑ ‑

Article number Type of installation

Viewing distance

Lamp/wattage Control 1 (.71)

TwIn‑Control

(.72)

SIngLE‑Control

(.81)

DUo‑Control

(.82)

Dimensions

671253.00X.y wall (surface) 19 m 1 x E27 25 w ‑ ‑ ‑ ‑ L 215, B 115, H 110

671254.91X.y wall (surface) 19 m 1 x TC‑EL 7 w ‑ ‑ ‑ ‑ L 215, B 115, H 110

Series: Rechteck (Universal 2)

Type of protection: IP 44 Protection class: II Voltage: 220 ‑ 240 V / 0 Hz, 50 ‑ 60 Hz Viewing distance: 19 m

For escape route identification or escape route illumination

Base: plastic. Diffuser: plastic, opal. 3 foils for escape route identification included. Integrated EB (where necessary).

Ballast: EB

Available colours (X): 2 = white, 3 = black

Accessories | Wire guardBall impact proof in accordance with DIn 18032, Part 3 and DIn VDE 0710, Part 13

wire guard and bracket: steel, white, powder‑coated. wire guard mounted with screws, can be opened for luminaire maintenance.

Wire guard for wall luminaires981167.002 L 380, B 295, H 185

Planning guide: Escape route illumination in accordance with EN 1838

E = 1 lx along the centre line

19 m

H

B

L

25

25114

85 85

214

6x10

h

d c b

a

Page 192: Emergency Lighting A1

190

EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy

Spacing table 671386.912

Lamp luminous flux:

Mains: 400 lm, Emergency: 400 lm

The following values are indicated in m

h a b c d

2.5 6.6 2.5 8.2 3.3

3.0 6.8 2.5 8.5 3.2

3.5 7.1 2.4 8.1 3.1

4.0 6.7 2.1 8.7 2.8

Spacing table 671387.912

Lamp luminous flux:

Mains: 600 lm, Emergency: 600 lm

The following values are indicated in m

h a b c d

2.5 7.6 3.3 9.7 3.9

3.0 8.0 3.1 9.6 4.0

3.5 7.8 3.1 10.1 3.9

4.0 8.3 3.0 11.0 3.8

Article number Type of installation

Luminous flux factor

Type Lamp/wattage Control 1 (.71)

TwIn‑Control

(.72)

SIngLE‑Control

(.81)

DUo‑Control

(.82)

Dimensions

671384.00X.y wall (surface), Ceiling (surface) 21 m high hood 1 x E27 60 w ‑ ‑ ‑ ‑ L 240, B 126, H 145

671387.92X.y wall (surface), Ceiling (surface) 21 m high hood 1 x TC‑DEL 10 w • • • • L 240, B 126, H 145

671386.91X.y wall (surface), Ceiling (surface) 21 m high hood 1 x TC‑EL 7 w • • • • L 240, B 126, H 145

For connecting diagrams, see pages 119 ‑ 121 | Article number explanations: see page 276Tender texts available upon request | Specifications subject to alteration

Series: Universal 3

Type of protection: IP 54 Protection class: I Voltage: 220 ‑ 240 V / 0 Hz, 50 ‑ 60 Hz Viewing distance: 21 m

For escape route identification or escape route illumination

Base: plastic. Diffuser: plastic, opal. Foil with escape route motif included.

Ballast: EB

Available colour (X): 2 = white

Accessories | Wire guardBall impact proof in accordance with DIn 18032, Part 3 and DIn VDE 0710, Part 13

wire guard and bracket: steel, white, powder‑coated. wire guard mounted with screws, can be opened for luminaire maintenance.

Wire guard for wall luminaires981167.002 L 380, B 295, H 185

Accessories | Pendant tubeSuspension tube Ø 10 mm, chrome, with canopy: white, powder‑coated and mounting material, with cable hanger, power supply cable for luminaire integrated in the tube.

Pendant tube90‑4164.002 LP 500 mm

Accessories | Wall extensionSteel, white powder‑coated

Wall extension981144.002 L 251, B 131, H 60

wall (surface), Ceiling (surface) (high hood)

Planning guide: Escape route illumination in accordance with EN 1838

E = 1 lx along the centre line

h

d c b

a

21 m

H

L B

13

13100

80 100240

70

126

5x11

Page 193: Emergency Lighting A1

191

EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy

For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration

Article number Type of installation

Viewing distance

Type Lamp/wattage Control 1 (.71)

TwIn‑Control

(.72)

SIngLE‑Control

(.81)

DUo‑Control

(.82)

Dimensions

671775.00X.y wall (surface) 21 m flat hood 1 x LED 2,1 w • • • • L 240, B 126, H 78

671782.00X.y wall (surface), Ceiling (surface) 21 m high hood 1 x LED 2,1 w • • • • L 240, B 126, H 145

Accessories | Wire guardBall impact proof in accordance with DIn 18032, Part 3 and DIn VDE 0710, Part 13

wire guard and bracket: steel, white, powder‑coated. wire guard mounted with screws, can be opened for luminaire maintenance.

Wire guard for wall luminaires981167.002 L 380, B 295, H 185

Accessories | Pendant tubeSuspension tube Ø 10 mm, chrome, with canopy: white, powder‑coated and mounting material, with cable hanger, power supply cable for luminaire integrated in the tube.

Pendant tube90‑4164.002 LP 500 mm

Accessories | Wall extensionSteel, white powder‑coated

Wall extension981144.002 L 251, B 131, H 60

Series: Universal 3 LED

Type of protection: IP 54 Protection class: II Voltage: 220 ‑ 240 V / 0 Hz, 50 ‑ 60 Hz Viewing distance: 21 m

For escape route identification

Base: plastic. Diffuser: plastic, opal. Foil with escape route motif included.

LED included.

Ballast: EB

Available colour (X): 2 = white

wall (surface), Ceiling (surface) (high hood)

wall (surface), Ceiling (surface) (flat hood)

21 m

H

L B

H

L B

13

13100

80 100240

70

126

5x11

13

13100

80 100240

70

126

5x11

Page 194: Emergency Lighting A1

192

EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy

Spacing table 671630.752

Lamp luminous flux:

Mains: 450 lm, Emergency: 450 lm

The following values are indicated in m

h a b c d

2.5 8.0 3.3 10.0 4.2

3.0 8.9 3.3 11.1 4.3

3.5 9.0 3.3 11.7 4.3

4.0 8.9 3.3 11.1 4.2

Spacing table 671629.752

Lamp luminous flux:

Mains: 450 lm, Emergency: 450 lm

The following values are indicated in m

h a b c d

2.5 8.7 3.8 10.8 4.3

3.0 9.0 4.0 10.7 4.4

3.5 10.2 4.0 11.2 4.5

4.0 10.1 4.0 11.8 4.4

Wire guard for wall luminaires981168.002 L 540, B 375, H 185

Article number Type of installation

Luminous flux factor

Type Lamp/wattage Control 1 (.71)

TwIn‑Control

(.72)

SIngLE‑Control

(.81)

DUo‑Control

(.82)

Dimensions

671629.75X.y wall (surface), Ceiling (surface) 25 m flat hood 1 x T16 (T5) 8 w • • • • L 344, B 144, H 78

671630.75X.y wall (surface), Ceiling (surface) 21 m high hood 1 x T16 (T5) 8 w • • • • L 344, B 144, H 148

For connecting diagrams, see pages 119 ‑ 121 | Article number explanations: see page 276Tender texts available upon request | Specifications subject to alteration

Series: Universal 4

Type of protection: IP 54 Protection class: II Voltage: 220 ‑ 240 V / 0 Hz, 50 ‑ 60 Hz Viewing distance: 21 m, 25 m

For escape route identification (only wall installation) or escape route illumination

Base: plastic (polycarbonate), diffuser: plastic (polycarbonate), opal, or refractor, plastic (polycarbonate) transparent, prismatic, motif foil included, EB incorporated.

Ballast: EB

Available colour (X): 2 = white

Mounting kit for chains/cable suspensions981583.002

Accessories | Pendant tubeSuspension tube Ø 10 mm, chrome, with canopy: white, powder‑coated and mounting material, with cable hanger, power supply cable for luminaire integrated in the tube.

Pendant tube90‑4164.002 LP 500 mm

Accessories | Wall extensionSteel bracket, white powder‑coated

Wall extension981485.002 L 374, B 147, H 75

Accessories | Wire guardBall impact proof in accordance with DIn 18032, Part 3 and DIn VDE 0710, Part 13

wire guard and bracket: steel, white, powder‑coated. wire guard mounted with screws, can be opened for luminaire maintenance.

wall (surface), Ceiling (surface) (high hood) opal

wall (surface), Ceiling (surface) (flat hood) transparent, prismatic

Planning guide: Escape route illumination in accordance with EN 1838

E = 1 lx along the centre line

h

d c b

a

H

L B

H

BL

50

250

15 110148,5

344

112,5 144

5x11

50

250

15 110148,5

344

112,5 144

5x11

21 m/25 m

Page 195: Emergency Lighting A1

193

EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy

For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration

Wire guard for wall luminaires981168.002 L 540, B 375, H 185

Article number Type of installation

Viewing distance

Type Lamp/wattage Control 1 (.71)

TwIn‑Control

(.72)

Single‑Control

(.81)

Duo‑Control

(.82)

Dimensions

671793.00X.y wall (surface) 25 m flat hood 1 x LED 4,5 w • • • • L 344, B 144, H 78

671820.00X.y wall (surface), Ceiling (surface) 21 m high hood 1 x LED 4,5 w • • • • L 344, B 144, H 148

Mounting kit for chains/cable suspensions981583.002

Accessories | Pendant tubeSuspension tube Ø 10 mm, chrome, with canopy: white, powder‑coated and mounting material, with cable hanger, power supply cable for luminaire integrated in the tube.

Pendant tube90‑4164.002 LP 500 mm

Accessories | Wall extensionSteel bracket, white powder‑coated

Wall extension981485.002 L 374, B 147, H 75

Accessories | Wire guardBall impact proof in accordance with DIn 18032, Part 3 and DIn VDE 0710, Part 13

wire guard and bracket: steel, white, powder‑coated. wire guard mounted with screws, can be opened for luminaire maintenance.

Series: Universal 4 LED

Type of protection: IP 54 Protection class: II Voltage: 220 ‑ 240 V / 0 Hz, 50 ‑ 60 Hz Viewing distance: 21 m, 25 m

For escape route identification

Base: plastic (polycarbonate); diffuser: plastic (polycarbonate), opal, or refractor: plastic (polycarbonate) transparent, prismatic, motif foil included.

LED included.

Ballast: EB

Available colour (X): 2 = white

wall (surface), Ceiling (surface) (high hood) opal

wall (surface), Ceiling (surface) (flat hood) tranparent, prismatic

H

L B

H

BL

50

250

15 110148,5

344

112,5 144

5x11

50

250

15 110148,5

344

112,5 144

5x11

21 m/25 m

Page 196: Emergency Lighting A1

194

EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy

wall (surface), Ceiling (surface) wall (surface)

LCS-Z Type of protection: IP 40

- Extremely flat housing, architecturally attractive design

- Reflector inside

- Lamp replacement without tools

- Easy to install

- Large viewing distance

- Easy to install

Page 197: Emergency Lighting A1

195

EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy

For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration

wall (surface) wall (surface)

Spacing table 671776.752

Lamp luminous flux:

Mains: 400 lm, Emergency: 400 lm

The following values are indicated in m

h a b c d

2.5 11.1 4.5 9.7 4.5

3.0 12.1 4.6 10.4 4.6

3.5 12.8 4.8 10.9 4.8

4.0 13.2 4.6 11.2 4.6

Article number Type of installation

Viewing distance

Lamp/wattage Control 1 (.71)

TwIn‑Control

(.72)

SIngLE‑Control

(.81)

DUo‑Control

(.82)

Dimensions

671774.75X.y wall (surface) 35 m 1 x T16 (T5) 8 w • • • • L 398, B 62, H 202

671776.75X.y wall (surface), Ceiling (surface) ‑ 1 x T16 (T5) 8 w • • • • L 398, B 62, H 202

Series: LCS‑Z

Type of protection: IP 40 Protection class: II Voltage: 220 ‑ 240 V / 0 Hz, 50 ‑ 60 Hz Viewing distance: 35 m

For escape route identification (only wall installation) or escape route illumination

Base and reflector: plastic (polycarbonate); refractor: plastic (PMMA) transparent, 3 foils for escape route identification included.

Ballast: EB

Available colour (X): 2 = white

Planning guide: Escape route illumination in accordance with EN 1838

E = 1 lx along the centre line

35 m

H

L B

H

L B

174202

250371

398

8016

18

Ø5

174202

250371

398

8016

18

Ø5

h

d c b

a

Page 198: Emergency Lighting A1

196

EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy

wall (surface), Ceiling (surface) wall (surface)

Varioplast I Type of protection: IP 54

- Ultraflat design

- IP 54 type of protection - dustproof and protected against water spray

- Installation-friendly construction: folding mounting plate with lampholder and ballast

- Shockproof verison

- Compact design

- Multi-purpose applications

Page 199: Emergency Lighting A1

197

EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy

For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration

wall (surface) Ceiling (surface)

Article number Type of installation

Viewing distance

Lamp/wattage Control 1 (.71)

TwIn‑Control

(.72)

SIngLE‑Control

(.81)

DUo‑Control

(.82)

Dimensions

671248.91X.y wall (surface) 24 m 1 x TC‑EL 11 w • • • • L 320, B 80, H 186

671291.75X.y wall (surface) 24 m 1 x T16 (T5) 6 w • • • • L 320, B 80, H 186

671247.91X.y wall (surface), Ceiling (surface) ‑ 1 x TC‑EL 11 w • • • • L 320, B 80, H 186

671290.75X.y wall (surface), Ceiling (surface) ‑ 1 x T16 (T5) 6 w • • • • L 320, B 80, H 186

Spacing table 671247.91X

Lamp luminous flux:

Mains: 900 lm, Emergency: 900 lm

The following values are indicated in m

h a b c d

2.5 10.8 4.6 13.0 5.4

3.0 11.9 4.9 13.8 5.8

3.5 12.9 5.2 14.5 6.0

4.0 13.5 5.4 14.3 6.2

Spacing table 671290.75X

Lamp luminous flux:

Mains: 300 lm, Emergency: 300 lm

The following values are indicated in m

h a b c d

2.5 7.5 3.2 8.7 3.6

3.0 8.2 3.3 9.5 3.7

3.5 8.8 3.4 10.2 3.7

4.0 8.7 3.4 9.5 3.7

Series: Varioplast I

Type of protection: IP 54 Protection class: I Voltage: 220 ‑ 240 V / 0 Hz, 50 ‑ 60 Hz Viewing distance: 24 m

For escape route identification (only in case of wall installation) or escape route illumination

Base: plastic (polycarbonate); refractor: plastic (polycarbonate) transparent, prismatic, 3 foils for escape route identification included.

Ballast: EB

Available colours (X): 2 = white, 3 = black

Accessories | Wire guardBall impact proof in accordance with DIn 18032, Part 3 and DIn VDE 0710, Part 13

wire guard and bracket: steel, white, powder‑coated. wire guard mounted with screws, can be opened for luminaire maintenance.

Wire guard for wall luminaires981168.002 L 540, B 375, H 185

Accessories | Set of screws with special anti‑theft key90‑4013.002 white90‑4013.003 black

Accessories | Wire guard, varnished22125.002 L 314, B 180, H 49 white22125.003 L 314, B 180, H 49 black

Planning guide: Escape route illumination in accordance with EN 1838

E = 1 lx along the centre line

24 m

H

B

L

H

B

L

6

27148

16

115

288320

15430

116 186

8016

5x8

6

27148

16

115

288320

15430

116 186

8016

5x8

h

d c b

a

Page 200: Emergency Lighting A1

198

EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy

Ceiling (recessed)

Turia Z Type of protection: IP 30

- Wide luminaire spacing for escape route illumination

- Energy efficient (consumption approx. 90% less than 13 W fluorescent lamp technology)

- Top quality LED technology

- Specially calculated thermal management

- Very low maintenance costs

- LED service life: approx. 50,000 hours

- Easy to install

- Compact design

- Inconspicuous design

- The self-contained module containing the battery can easily be installed and removed through the ceiling cutout

Page 201: Emergency Lighting A1

199

EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy

For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration

Ceiling (recessed)

Spacing table 671919.002

Lamp luminous flux:

Mains: 148 lm, Emergency: 148 lm

The following values are indicated in m

h a b c d

2.5 7.3 3.0 7.3 3.0

3.0 8.2 3.4 8.2 3.4

3.5 8.9 3.6 8.9 3.6

4.0 9.5 3.7 9.5 3.7

Step 1 Step 2

Step 3 Step 4

Article number Type of installation

Lamp/wattage Control 1 (.71)

TwIn‑Control

(.72)

SIngLE‑Control

(.81)

DUo‑Control

(.82)

Dimensions

671919.00X.y Ceiling (recessed) 1 x LED 2 w • • • • D 50, H 2, DA 42, HE 45

Series: Turia Z

Type of protection: IP 30 Protection class: I with .y, II without .y Voltage: 220 ‑ 240 V / 0 Hz, 50 ‑ 60 Hz Ceiling thickness: 15‑35 mm

For escape route illumination

Housing: die‑cast aluminium: cover ring: plastic; EB in separate ballast box with connection cable.

LED included.

Ballast: EB

Available colour (X): 2 = white

Planning guide: Escape route illumination in accordance with EN 1838

E = 1 lx along the centre line

HDAD

HE

Ø50 Ø42

h

d c b

a

Page 202: Emergency Lighting A1

200

EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy

Example

Edo Type of protection: IP 20

- Wide luminaire spacing for escape route illumination

- Energy efficient (consumption approx. 80% less than 13 W fluorescent lamp technology)

- Top quality LED technology

- Specially calculated thermal management

- Very low maintenance costs

- LED service life: approx. 50,000 hours

- Easy to install

- Compact design

- Inconspicuous design

Edo 1 Installation in existing luminiares

Edo 2 Installation in metal ceilings

Edo 4 Edo 5

+

+

=

Page 203: Emergency Lighting A1

201

EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy

For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration

Edo 1 Retrofitting kit Edo 2 Retrofitting kit Ceiling (recessed) Edo 4 Ceiling (recessed) Edo 5

Accessories | Fixing bracket for Edo 1Bracket for fixing Edo 1 into recessed luminiares such as downlights or louvre luminaires. Bracket is to be installed in existing reflector or louvre.

Fixing bracket for Edo 1981778.000

Spacing table 671950.00X

Lamp luminous flux:

Mains: 109 lm, Emergency: 109 lm

The following values are indicated in m

h a b c d

2.5 7.7 3.0 7.7 3.0

3.0 8.5 3.2 8.5 3.2

3.5 8.9 3.2 8.9 3.2

4.0 9.1 3.2 9.1 3.2

Edo 1

Edo 2

Article number Type of installation

Type Lamp/wattage Control 1 (.71)

TwIn‑Control

(.72)

SIngLE‑Control

(.81)

DUo‑Control

(.82)

Dimensions

671950.00X.y Retrofitting kit Edo 1 1 x LED 2 w • • • • D 22, H 8, DA 10.5, HE 15

671951.00X.y Installation in metal ceilings Edo 2 1 x LED 2 w • • • • D 27, H 1, DA 22, HE 23

671936.00X Ceiling (recessed) Edo 4 1 x LED 2 w • • • • D 50, H 3, DA 40, HE 45

671937.00X Ceiling (recessed) Edo 5 1 x LED 2 w • • • • L 50, B 50, H 3, DA 40, HE 45

Series: Edo

Type of protection: IP 30 Protection class: I with .y, II without .y Voltage: 220 ‑ 240 V / 0 Hz, 50 ‑ 60 Hz Ceiling thickness: 1‑8 mm (Edo 1 and Edo 2) Ceiling thickness: 15‑35 mm (Edo 4 and Edo 5)

For escape route illumination

Housing: die‑cast aluminium; cover ring: plastic (only Edo 4 + 5), separate ballast box with connecting cable.

LED included.

Ballast: EB

Available colour (X): 2 = white (Edo 4 and Edo 5) 4 = aluminium (Edo 1 and Edo 2)

Table applies to all Edo series luminaires

Planning guide: Escape route illumination in accordance with EN 1838

E = 1 lx along the centre line

H

DA

HE

D

DA

D

H

HE

HDAD

HE

Ø50 Ø40 Ø50 Ø40

HBAB

HE

LA L

h

d c b

a

Page 204: Emergency Lighting A1

202

EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy

Ceiling (surface) Ceiling (recessed)

Lucio Type of protection: IP 40

- Wide luminaire spacing for escape route illumination

- Energy efficient (consumption approx. 90% less than 13 W fluorescent lamp technology)

- Top quality LED technology

- Specially calculated thermal management

- Very low maintenance costs

- LED service life: approx. 50,000 hours

- Compact design

- Easy to install

- Multi-purpose applications, either as recessed or surface mounted ceiling luminaire

Page 205: Emergency Lighting A1

203

EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy

For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration

Ceiling (surface) Ceiling (recessed)

Spacing table 671916.002

Lamp luminous flux:

Mains: 56 lm, Emergency: 56 lm

The following values are indicated in m

h a b c d

2.5 5.2 2.1 5.2 2.1

3.0 5.7 2.0 5.7 2.0

3.5 6.0 1.7 6.0 1.7

4.0 5.9 1.0 5.9 1.0

Article number Type of installation

Lamp/wattage Control 1 (.71)

TwIn‑Control

(.72)

SIngLE‑Control

(.81)

DUo‑Control

(.82)

Dimensions

671916.00X.y Ceiling (surface), Ceiling (recessed) 1 x LED 3 w ‑ ‑ ‑ ‑

Surface installation: D 120, H 45

Recessed installation: D 120, H 3, DA 105, HE 42

Series: Lucio

Type of protection: IP 40 Protection class: II Voltage: 220 ‑ 240 V / 0 Hz, 50 ‑ 60 Hz Ceiling thickness: 5‑25 mm

For escape route illumination

Housing: plastic. Accessories for recessed and surface ceiling installation included.

LED included.

Ballast: EB

Available colour (X): 2 = white

Planning guide: Escape route illumination in accordance with EN 1838

E = 1 lx along the centre line

H

D

104

HDAD

HE

51

25(78)

Ø4,2

Ø16

Ø12059

73,5Ø4,2

Ø120 Ø105

h

d c b

a

Page 206: Emergency Lighting A1

204

EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy

Centryxx Type of protection: IP 40

- Wide luminaire spacing for escape route illumination

- Design matches modern architectural styles

- Energy efficient (consumption approx. 90% less than 13 W fluorescent lamp technology)

- Top quality LED technology

- Specially calculated thermal management

- Very low maintenance costs

- LED service life: approx. 50,000 hours

- Easy to install

Ceiling (recessed), squareCeiling (surface) Ceiling (recessed), round

Page 207: Emergency Lighting A1

205

EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy

For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration

Spacing table 671841.002

Lamp luminous flux:

Mains: 180 lm, Emergency: 180 lm

The following values are indicated in m

h a b c d

2.5 3.4 0.9 12.6 5.6

3.0 3.0 0.8 14.2 6.4

3.5 2.6 0.7 16.1 7.1

4.0 2.4 0.0 10.5 0.0

Article number Type of installation

Type Lamp/wattage Control 1 (.71)

TwIn‑Control

(.72)

SIngLE‑Control

(.81)

DUo‑Control

(.82)

Dimensions

671841.00X.y Ceiling (surface) square 1 x LED 3 w ‑ ‑ ‑ • L 180, B 180, H 27

671839.00X.y Ceiling (recessed) square 1 x LED 3 w ‑ ‑ ‑ • L 220, B 220, H 3 DA 185, HE 73

671837.00X.y Ceiling (recessed) round 1 x LED 3 w ‑ ‑ ‑ • D 200, H 3 DA 185, HE 73

Series: Centryxx

Type of protection: IP 20 (wall (surface)), IP 40 (Ceiling (recessed)) Protection class: I Voltage: 220 ‑ 240 V / 0 Hz, 50 ‑ 60 Hz

For escape route illumination

Housing: die‑cast aluminium, powder‑coated; transparent plastic diffuser for optimum illumination of escape route.

Ballast: EB

Available colour (X): 2 = white

Ceiling (recessed), square Ceiling (recessed), roundCeiling (surface)

Table applies to all Centryxx series luminaires

Planning guide: Escape route illumination in accordance with EN 1838

E = 1 lx along the centre line

HDAL

HE

B

HDAD

HE

B

L H

Ø200 Ø185 Ø200 Ø185

Ø5

180

90180

90

51

Ø5

h

d c b

a

Page 208: Emergency Lighting A1

206

EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy

Ceiling (surface) Ceiling (recessed)

Solyxx Type of protection: IP 20

- Wide luminaire spacing for escape route illumination

- Subdued design

- Energy efficient (consumption approx. 90% less than 13 W fluorescent lamp technology)

- Top quality LED technology

- Specially calculated thermal management

- Very low maintenance costs

- LED service life: approx. 50,000 hours

- Easy to install

Page 209: Emergency Lighting A1

207

EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy

For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration

Ceiling (surface) Ceiling (recessed)

Spacing table 671854.002 und 671835.002

Lamp luminous flux:

Mains: 178 lm, Emergency: 178 lm

The following values are indicated in m

h a b c d

2.5 8.6 3.7 5.2 2.1

3.0 9.6 3.9 5.6 2.1

3.5 10.5 4.3 5.9 2.1

4.0 11.2 4.6 6.2 2.2

Article number Type of installation

Lamp/wattage Control 1 (.71)

TwIn‑Control

(.72)

SIngLE‑Control

(.81)

DUo‑Control

(.82)

Dimensions

671854.00X.y Ceiling (surface) 1 x LED 3 w ‑ ‑ • ‑ L 118, B 118, H 58

671835.00X.y Ceiling (recessed) 1 x LED 3 w ‑ ‑ • • L 120, B 120, H 5 LA 108 x BA 108, HE 80

Series: Solyxx

Type of protection: IP 20 Protection class: I Voltage: 220 ‑ 240 V / 0 Hz, 50 ‑ 60 Hz Ceiling thickness: 1‑25 mm

For escape route illumination

Housing and anti‑glare shield: aluminium, white; for surface installation: white plastic housing; plastic diffuser: prismatic.

Ballast: EB

Available colour (X): 2 = white

Planning guide: Escape route illumination in accordance with EN 1838

E = 1 lx along the centre line

L

B

H

Ø6

93118

18

70 25 94 118

15

108120

108120

HBAB

HE

LA L

h

d c b

a

Page 210: Emergency Lighting A1

208

EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy

Ceiling (recessed)

Energo TC 175 Type of protection: IP 23

- Design continuity to the general lighting programme. We offer an extensive range of emergency lighting and general lighting systems. As such, we can provide our customers with integrated solutions for all areas of application, depending on their construction projects.

- Housing made of top quality die-cast aluminium

- Wide luminaire spacing for escape route illumination

- Modern design

- Bezel ring made of die-cast aluminium

- Infinitely adjustable spring fastening system

- EBs in separate ballast box

- Modular recessed luminaire with small recessed depth

- Easy to install

- For ceiling thicknesses of 1-40 mm

Page 211: Emergency Lighting A1

209

EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy

For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration

Ceiling (recessed)

Spacing table 671877.92X und 671879.92X

Lamp luminous flux:

Mains: 900 lm, Emergency: 900 lm

The following values are indicated in m

h a b c d

2.5 7.7 2.8 7.7 2.8

3.0 8.1 2.9 8.1 2.9

3.5 8.4 2.8 8.4 2.8

4.0 8.3 2.7 8.3 2.7

Spacing table 671878.96X und 671880.96X

Lamp luminous flux:

Mains: 1200 lm, Emergency: 1200 lm

The following values are indicated in m

h a b c d

2.5 7.5 2.9 7.5 2.9

3.0 8.1 3.1 8.1 3.1

3.5 8.5 3.0 8.5 3.0

4.0 8.7 3.0 8.7 3.0

Article number Type of installation

Lamps Mains/

Emergency

Lamp/wattage Control 1 (.71)

TwIn‑Control

(.72)

SIngLE‑Control

(.81)

DUo‑Control

(.82)

Dimensions

671877.92X.y Ceiling (recessed) 1 / 1 1 x TC‑DEL 13 w • • • • D 188, H 4, DA 175, HE 100

671879.92X.y Ceiling (recessed) 2 / 1 2 x TC‑DEL 13 w • • • • D 188, H 4, DA 175, HE 100

671878.96X.y Ceiling (recessed) 1 / 1 1 x TC‑DEL 18 w • • • • D 188, H 4, DA 175, HE 100

671880.96X.y Ceiling (recessed) 2 / 1 2 x TC‑DEL 18 w • • • • D 188, H 4, DA 175, HE 100

Series: Energo TC 175

Type of protection: IP 23 with bezel ring without safety glass, IP 44 with bezel ring including safety glass Protection class: I Voltage: 220 ‑ 240 V / 0 Hz, 50 ‑ 60 Hz Ceiling thickness: 1‑40 mm

For escape route illumination

Modular design: A bezel ring must always be ordered for each basic luminaire!

Recess and bezel ring: die‑cast aluminium, bezel ring with bayonet fixing; bracket: galvanised sheet steel; reflector: alumi‑nium, highly polished anodised finish; ceiling installation with spring system. EB in separate ballast box with connecting cable L 400 mm in flexible hose, 5‑pole double terminal for through‑wiring.

Ballast: EB

Available colour (X) Basic luminaire: 4 = silver metallic

Moulded housing981656.000 Moulded housing L 500, B 250, H 160 mm

Panel mounting frame98102.002/176 Panel mounting frame Dimensions 285 x 285 mm

Bezel rings with safety glass, D 194 mm, H 9 mm 981653.002 Safety glass, transparent981653.004 Safety glass, transparent

Bezel rings without safety glass, D 194 mm, H 9 mm981653.102981653.104

Planning guide: Escape route illumination in accordance with EN 1838

E = 1 lx along the centre line

Ø188 Ø175

HDAD

HE

h

d c b

a

Page 212: Emergency Lighting A1

210

EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy

Ceiling (recessed)

Energo TC 210 Type of protection: IP 23

- Design continuity to the general lighting programme. We offer an extensive range of emergency lighting and general lighting systems. As such, we can provide our customers with integrated solutions for all areas of application, depending on their construction projects.

- Housing made of top quality die-cast aluminium

- Wide luminaire spacing for escape route illumination

- Modern design

- Bezel ring made of die-cast aluminium

- Infinitely adjustable spring fastening system

- EBs in separate ballast box

- Modular recessed luminaire with small recessed depth

- Easy to install

- For ceiling thicknesses of 1-40 mm

Page 213: Emergency Lighting A1

211

EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy

For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration

Ceiling (recessed)

Spacing table 671883.83X und 671884.83X

Lamp luminous flux:

Mains: 1800 lm, Emergency: 1800 lm

The following values are indicated in m

h a b c d

2.5 9.4 3.8 9.4 3.8

3.0 10.3 4.1 10.3 4.1

3.5 11.0 4.1 11.0 4.1

4.0 11.5 4.1 11.5 4.1

Article number Type of installation

Lamps Mains/

Emergency

Lamp/wattage Control 1 (.71)

TwIn‑Control

(.72)

SIngLE‑Control

(.81)

DUo‑Control

(.82)

Dimensions

671883.83X.y Ceiling (recessed) 1 / 1 1 x TC‑TEL 32 w • • • • D 220, H 4, DA 210, HE 120

671884.83X.y Ceiling (recessed) 2 / 1 2 x TC‑TEL 32 w • • • • D 220, H 4, DA 210, HE 120

Series: Energo TC 210

Type of protection: IP 23 with bezel ring without safety glass, IP 44 with bezel ring including safety glass Protection class: I Voltage: 220 ‑ 240 V / 0 Hz, 50 ‑ 60 Hz Ceiling thickness: 1‑40 mm

For escape route illumination

Modular design: A bezel ring must always be ordered for each basic luminaire!

Recess and bezel ring: die‑cast aluminium, bezel ring with bayonet fixing; bracket: galvanised sheet steel; reflector: alumi‑nium, highly polished anodised finish; ceiling installation with spring system. EB in separate ballast box with connecting cable L 400 mm in flexible hose, 5‑pole double terminal for through‑wiring.

Ballast: EB

Available colour (X) Basic luminaire: 4 = silver metallic

Moulded housing981662.000 Moulded housing L 450, B 300, H 200 mm

Panel mounting frame98102.002/215 Panel mounting frame Dimensions 285 x 285 mm

Bezel rings with decorative attachment, D 250 mm, H 38 mm 981660.002 Decorative glass, transparent981660.004 Decorative glass, transparent

Bezel rings with safety glass, D 227 mm, H 9 mm 981659.002 Safety glass, transparent981659.004 Safety glass, transparent

Planning guide: Escape route illumination in accordance with EN 1838

E = 1 lx along the centre line

Ø220 Ø210

HDAD

HE

h

d c b

a

Page 214: Emergency Lighting A1

212

EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy

Ceiling (surface)

Andho TC Flat Type of protection: IP 23

- Design continuity to the general lighting programme. We offer an extensive range of emergency lighting and general lighting systems. As such, we can provide our customers with integrated solutions for all areas of application, depending on their construction projects.

- Design matches modern architectural styles

- Housing made of top quality die-cast aluminium

- Top quality reflector made of aluminium, highly polished anodised finish

Page 215: Emergency Lighting A1

213

EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy

For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration

Ceiling (surface)

Accessories981678.002 Suspension cable (2m) with 5‑pole power supply cable (IP 23)981678.004 Suspension cable (2m) with 5‑pole power supply cable (IP 23)

Spacing table 671886.84X

Luminaire luminous flux:

Mains: 2400 lm, Emergency: 2400 lm

The following values are indicated in m

h a b c d

2.5 10.5 4.7 10.2 4.5

3.0 12.7 5.6 12.3 5.4

3.5 14.8 6.3 14.2 6.0

4.0 16.1 6.9 15.4 6.4

Spacing table 671885.82X

Luminaire luminous flux:

Mains: 1800 lm, Emergency: 1800 lm

The following values are indicated in m

h a b c d

2.5 10.5 4.7 10.2 4.5

3.0 12.7 5.4 12.2 5.2

3.5 14.1 5.8 13.4 5.6

4.0 15.2 6.4 14.4 6.1

Spacing table 671887.83X

Luminaire luminous flux:

Mains: 3600 lm, Emergency: 3600 lm

The following values are indicated in m

h a b c d

2.5 10.5 4.7 10.2 4.5

3.0 12.7 5.6 12.3 5.4

3.5 14.8 6.5 14.3 6.3

4.0 16.9 7.5 16.4 7.2

Article number Type of installation

Lamps Mains/

Emergency

Lamp/wattage Control 1 (.71)

TwIn‑Control

(.72)

SIngLE‑Control

(.81)

DUo‑Control

(.82)

Dimensions

671885.82X.y Ceiling (surface) 2 / 2 2 x TC‑TEL 13 w • • • • D 230, H 140

671886.84X.y Ceiling (surface) 2 / 2 2 x TC‑TEL 18 w • • • • D 230, H 140

671887.83X.y Ceiling (surface) 2 / 2 2 x TC‑TEL 26 w • • • • D 230, H 140

Series: Andho TC Flat

Type of protection: IP 23 Protection class: I Voltage: 220 ‑ 240 V / 0 Hz, 50 ‑ 60 Hz

For escape route illumination

Housing: aluminium extrusion profile, powder‑coated; cover ring and ceiling base: die‑cast aluminium, powder‑coated, with bayonet fixing; reflector: aluminium, highly polished anodised finish; EB incorporated, 5‑pole double terminal for through‑wiring.

Ballast: EB

Available colours (X): 2 = white, 4 = silver metallic

Planning guide: Escape route illumination in accordance with EN 1838

E = 1 lx along the centre line

H

D

178

45178

Ø230

Ø7

h

d c b

a

Page 216: Emergency Lighting A1

214

EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy

Ceiling (surface)

Andho TC Flat IP 65 Type of protection: IP 65

- Design continuity to the general lighting programme. We offer an extensive range of emergency lighting and general lighting systems. As such, we can provide our customers with integrated solutions for all areas of application, depending on their construction projects.

- Design matches modern architectural styles

- Housing made of top quality die-cast aluminium

- Top quality reflector made of aluminium, highly polished anodised finish

Page 217: Emergency Lighting A1

215

EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy

For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration

Ceiling (surface)

Accessories981678.002 Suspension cable (2m) with 5‑pole power supply cable (IP 23)981678.004 Suspension cable (2m) with 5‑pole power supply cable (IP 23)

Spacing table 671888.82X

Luminaire luminous flux:

Mains: 1800 lm, Emergency: 1800 lm

The following values are indicated in m

h a b c d

2.5 9.9 4.5 9.4 4.1

3.0 11.6 4.9 11.0 4.8

3.5 12.7 5.3 12.1 5.1

4.0 13.8 5.9 13.2 5.7

Spacing table 671889.84X

Luminaire luminous flux:

Mains: 2400 lm, Emergency: 2400 lm

The following values are indicated in m

h a b c d

2.5 9.9 4.5 9.4 4.1

3.0 11.9 5.2 11.3 4.9

3.5 13.5 5.8 12.8 5.6

4.0 14.6 6.4 13.8 5.9

Spacing table 671890.83X

Luminaire luminous flux:

Mains: 3600 lm, Emergency: 3600 lm

The following values are indicated in m

h a b c d

2.5 9.9 4.5 9.4 4.1

3.0 11.9 5.4 11.3 4.9

3.5 13.9 6.3 13.2 5.8

4.0 15.8 6.6 15.0 6.4

Article number Type of installation

Lamps Mains/

Emergency

Lamp/wattage Control 1 (.71)

TwIn‑Control

(.72)

SIngLE‑Control

(.81)

DUo‑Control

(.82)

Dimensions

671888.82X.y Ceiling (surface) 2 / 2 2 x TC‑TEL 13 w • • • • D 230, H 148

671889.84X.y Ceiling (surface) 2 / 2 2 x TC‑TEL 18 w • • • • D 230, H 148

671890.83X.y Ceiling (surface) 2 / 2 2 x TC‑TEL 26 w • • • • D 230, H 148

Series: Andho TC Flat IP 65

Type of protection: IP 65 Protection class: I Voltage: 220 ‑ 240 V / 0 Hz, 50 ‑ 60 Hz

For escape route illumination

Housing: aluminium extrusion profile, powder‑coated; ceiling base: die‑cast aluminium, powder‑coated, with bayonet fixing; cover ring: die‑cast aluminium, powder‑coated, screwed on the luminaire; safety glass, transparent; reflector: aluminium, highly polished anodised finish; EB incorporated, 5‑pole double terminal for through‑wiring.

Ballast: EB

Available colours (X): 2 = white, 4 = silver metallic

Planning guide: Escape route illumination in accordance with EN 1838

E = 1 lx along the centre line

H

D

178

45178

Ø230

Ø7

h

d c b

a

Page 218: Emergency Lighting A1

216

EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy

Ceiling (recessed)

Arelo® Type of protection: IP 20

- Design continuity to the general lighting programme. We offer an extensive range of emergency lighting and general lighting systems. As such, we can provide our customers with integrated solutions for all areas of application, depending on their construction projects.

- Recessed ring made of die-cast aluminium

- Top quality reflector made of aluminium, highly polished anodised finish

- Wide beam light distribution

- All versions with EB in separate ballast box

- Simple spring system for installation without tools

Page 219: Emergency Lighting A1

217

EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy

For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration

Ceiling (recessed)

Cover screens with spring fastening IP 43981734.000 Safety glass, transparent

Spacing table 671871.962

Luminaire luminous flux:

Mains: 2400 lm, Emergency: 2400 lm

The following values are indicated in m

h a b c d

2.5 10.3 4.7 10.6 4.9

3.0 12.3 5.4 12.7 5.8

3.5 13.7 6.0 14.8 6.5

4.0 15.0 6.6 16.2 7.2

Spacing table 671869.962

Lamp luminous flux:

Mains: 1200 lm, Emergency: 1200 lm

The following values are indicated in m

h a b c d

2.5 10.4 4.5 10.8 4.9

3.0 11.8 4.9 12.4 5.4

3.5 13.0 5.3 13.8 6.0

4.0 14.0 5.9 15.1 6.4

Spacing table 671870.952

Lamp luminous flux:

Mains: 1800 lm, Emergency: 1800 lm

The following values are indicated in m

h a b c d

2.5 11.6 4.9 11.3 5.1

3.0 12.8 5.6 13.1 5.8

3.5 14.2 6.0 14.6 6.5

4.0 15.5 6.4 16.0 6.9

Spacing table 671872.952

Luminaire luminous flux:

Mains: 3600 lm, Emergency: 3600 lm

The following values are indicated in m

h a b c d

2.5 10.4 4.7 10.6 4.9

3.0 12.4 5.6 12.7 5.8

3.5 14.4 6.3 14.8 6.8

4.0 15.8 6.9 16.9 7.5

Article number Type of installation

Lamps Mains/

Emergency

Lamp/wattage Control 1 (.71)

TwIn‑Control

(.72)

SIngLE‑Control

(.81)

DUo‑Control

(.82)

Dimensions

671869.96X.y Ceiling (recessed) 1 / 1 1 x TC‑DEL 18 w • • • • D 218, H 3, DA 200, HE 106

671871.96X.y Ceiling (recessed) 2 / 2 2 x TC‑DEL 18 w • • • • D 218, H 3, DA 200, HE 106

671870.95X.y Ceiling (recessed) 1 / 1 1 x TC‑DEL 26 w • • • • D 218, H 3, DA 200, HE 106

671872.95X.y Ceiling (recessed) 2 / 2 2 x TC‑DEL 26 w • • • • D 218, H 3, DA 200, HE 106

Series: Arelo®

Type of protection: IP 20 Protection class: I Voltage: 220 ‑ 240 V / 0 Hz, 50 ‑ 60 Hz Ceiling thickness: 1‑25 mm

For escape route illumination

Mounting frame: die‑cast aluminium, powder‑coated; bracket: galvanised sheet steel; reflector: aluminium, highly polished anodised finish, separate ballast box; length of cable between luminaire and ballast box: 400 mm; suitable for through‑wiring.

Ballast: EB

Available colour (X): 2 = white

Planning guide: Escape route illumination in accordance with EN 1838

E = 1 lx along the centre line

HE

DAD

H

Ø218 Ø200

h

d c b

a

Page 220: Emergency Lighting A1

218

EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy

wall (surface), Ceiling (surface)Semi‑recessed installation (wall, ceiling)

Mondana Type of protection: IP 65

- Design continuity to the general lighting programme. We offer an extensive range of emergency lighting and general lighting systems. As such, we can provide our customers with integrated solutions for all areas of application, depending on their construction projects.

- Design matches modern architectural styles

- Diffuser: glass or PE sintered glass (polyethylene), shockproof

- IP 65 provides safe protection against humidity - dust and insects cannot penetrate the luminaire

- Gore™ diaphragm valve for pressure equalisation and prevention of condensation

- Easy to install

- Wide range of applications thanks to various types of installation

- Lamp replacement without tools

Page 221: Emergency Lighting A1

219

EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy

For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration

wall (surface), Ceiling (surface) D 500 and D 550

Semi‑recessed installation (wall, ceiling) DA 310

wall (surface), Ceiling (surface) D 390

Semi‑recessed installation (wall, ceiling) DA 390

Spacing table 671801.00X und 671981.00X

Lamp luminous flux:

Mains: 1800 lm, Emergency: 1800 lm

The following values are indicated in m

h a b c d

2.5 11.9 4.7 11.9 4.7

3.0 12.7 4.9 12.7 4.9

3.5 13.4 5.1 13.4 5.1

4.0 14.0 5.3 14.0 5.3

Spacing table 671800.80X

Luminaire luminous flux:

Mains: 5000 lm, Emergency: 5000 lm

The following values are indicated in m

h a b c d

2.5 14.5 5.8 14.5 5.8

3.0 17.4 7.0 17.4 7.0

3.5 18.6 7.5 18.6 7.5

4.0 19.6 7.8 19.6 7.8

Spacing table 671790.80X

Luminaire luminous flux:

Mains: 5000 lm, Emergency: 5000 lm

The following values are indicated in m

h a b c d

2.5 14.5 5.8 14.5 5.8

3.0 17.4 7.0 17.4 7.0

3.5 18.6 7.5 18.6 7.5

4.0 19.6 7.8 19.6 7.8

Spacing table 671799.80X

Luminaire luminous flux:

Mains: 5000 lm, Emergency: 5000 lm

The following values are indicated in m

h a b c d

2.5 14.5 5.8 14.5 5.8

3.0 17.4 7.0 17.4 7.0

3.5 18.6 7.5 18.6 7.5

4.0 19.6 7.8 19.6 7.8

Spacing table 671791.80X

Luminaire luminous flux:

Mains: 5000 lm, Emergency: 5000 lm

The following values are indicated in m

h a b c d

2.5 11.6 5.8 11.5 5.8

3.0 16.9 7.0 16.9 7.0

3.5 19.5 7.8 19.5 7.8

4.0 20.5 8.2 20.5 8.2

Accessories | Moulded housing

Moulded housing 981630.002 for Mondana D 390981631.002 for Mondana D 500981631.002 for Mondana D 550

Article number Type of installation

Type Lamps Mains/

Emergency

Lamp/wattage Control 1 (.71)

TwIn‑Control

(.72)

SIngLE‑Control

(.81)

DUo‑Control

(.82)

Dimensions

671801.00X.y Semi‑recessed instal‑lation (wall, ceiling) glass 1 / 1 1 x T16‑R 22 w • • • • D 390, H 57

DA 310, HE 96

671800.80X.y Semi‑recessed instal‑lation (wall, ceiling) glass 2 / 2 1 x T16‑R 22 w +

1 x T16‑R 40 w • • • • D 500, H 78 DA 390, HE 100

671799.80X.y Semi‑recessed instal‑lation (wall, ceiling) PE 2 / 2 1 x T16‑R 22 w +

1 x T16‑R 40 w • • • • D 550, H 85 DA 390, HE 100

671781.00X.y wall (surface), Ceiling (surface) glass 1 / 1 1 x T16‑R 22 w • • • • D 390, H 101

671790.80X.y wall (surface), Ceiling (surface) glass 2 / 2 1 x T16‑R 22 w +

1 x T16‑R 40 w • • • • D 500, H 128

671791.80X.y wall (surface), Ceiling (surface) PE 2 / 2 1 x T16‑R 22 w +

1 x T16‑R 40 w • • • • D 550, H 135

Series: Mondana

Type of protection: IP 65 Protection class: I Voltage: 220 ‑ 240 V / 0 Hz, 50 ‑ 60 Hz Ceiling thickness: 10‑30 mm

For escape route illumination

Base: plastic (polycarbonate), microstructure coating; diffuser: plastic (polyethylene) or mouth‑blown opal glass, satin finish; diffuser fastening: screwneck; housing for semi‑recessed installation in walls and ceilings: powder‑coated aluminium. Standard gore™ Protective Vents diaphragm valve for reduction of condensation.

Ballast: EB

Available colours (X): 2 = white, 4 = silver metallic

Planning guide: Escape route illumination in accordance with EN 1838

E = 1 lx along the centre line

D H

D H

HE

DA

D H

D H

HE

DA

Ø310

13170

Ø300

Ø5,5

70Ø390

140

5242,5

Ø380

Ø5,5

7065

h

d c b

a

Page 222: Emergency Lighting A1

220

EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy

Flat Polymero® Type of protection: IP 40

- Design continuity to the general lighting programme. We offer an extensive range of emergency lighting and general lighting systems. As such, we can provide our customers with integrated solutions for all areas of application, depending on their construction projects.

- Design matches modern architectural styles

- Compact design

- Extremely high Light Output Ratio of up to 81%

- Easy to install

- Low maintenance costs

- Wide range of applications thanks to various types of installation

wall (surface), Ceiling (surface)

Page 223: Emergency Lighting A1

221

EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy

For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration

Serie: Flat Polymero®

Type of protection: IP 40 Protection class: I Voltage: 220 ‑ 240 V / 0 Hz, 50 ‑ 60 Hz

For escape route illumination

Base: powder‑coated metal; diffuser: plastic (PMMA), opal, or plastic (polycarbonate), shockproof. Diffuser fastening with patented system (push system).

Ballast: EB

Available colour (X): 2 = white

wall (surface), Ceiling (surface)

Spacing table 671952.002.1 und 671952.002.2

Lamp luminous flux:

Mains: 1800 lm, Emergency: 1800 lm

The following values are indicated in m

h a b c d

2.5 13.9 5.3 13.9 5.3

3.0 14.8 5.8 14.8 5.8

3.5 15.7 6.0 15.7 6.0

4.0 16.4 6.4 16.4 6.4

Article number Type of installation

Type Lamp/wattage Control 1 (.71)

TwIn‑Control

(.72)

SIngLE‑Control

(.81)

DUo‑Control

(.82)

Dimensions

671952.00X.1.y wall (surface), Ceiling (surface) PMMA 1 x T16‑R 22 w • • • • D 360, H 100

671952.00X.2.y wall (surface), Ceiling (surface) PC 1 x T16‑R 22 w • • • • D 360, H 100

Planning guide: Escape route illumination in accordance with EN 1838

E = 1 lx along the centre line

D

H

100

173

Ø324

Ø5,5

5030

25

h

d c b

a

Page 224: Emergency Lighting A1

222

EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy

Flat Polymero® PMMA

Flat Polymero® PC

Type of protection: IP 43 (Ceiling (surface)), IP 44 (Wall (surface))

- Design continuity to the general lighting programme. We offer an extensive range of emergency lighting and general lighting systems. As such, we can provide our customers with integrated solutions for all areas of application, depending on their construction projects.

- Architecturally attractive design

- Compact design

- Easy to install

- With spring system - for opening the luminaire without tools - for gently detaching and positioning the diffuser

wall (surface), Ceiling (surface)

Page 225: Emergency Lighting A1

223

EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy

For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration

wall (surface), Ceiling (surface)

Accessories | Decorative rings, metal, for series: Flat Polymero® PMMA and PCAvailable colours: Decorative ring, painted (Z): 2 = white, 61 = ultramarine blue, 76 = rape yellow, 82 = ruby red, 9 = light grey. other RAL colours available on request

Available colours: Decorative ring, metallised (Z): 4 = chrome, 42 = nickel, matt, 5 = brass

Decorative rings, metalDecorative ring D 325 mm, for diffuser D 305 mm981224.00Z D 325, H 10

Spacing table 671959.952.2

Lamp luminous flux:

Mains: 1800 lm, Emergency: 1800 lm

The following values are indicated in m

h a b c d

2.5 13.0 5.2 13.0 5.2

3.0 13.1 5.6 13.1 5.6

3.5 14.3 5.8 14.3 5.8

4.0 15.1 6.1 15.1 6.1

Spacing table 671958.962.1

Lamp luminous flux:

Mains: 1200 lm, Emergency: 1200 lm

The following values are indicated in m

h a b c d

2.5 10.8 4.6 10.8 4.6

3.0 12.1 4.8 12.1 4.8

3.5 12.8 5.0 12.8 5.0

4.0 12.8 5.2 12.8 5.2

Spacing table 671959.952.1

Lamp luminous flux:

Mains: 1800 lm, Emergency: 1800 lm

The following values are indicated in m

h a b c d

2.5 13.0 5.2 13.0 5.2

3.0 13.1 5.6 13.1 5.6

3.5 14.3 5.8 14.3 5.8

4.0 15.1 6.1 15.1 6.1

Spacing table 671958.962.2

Lamp luminous flux:

Mains: 1200 lm, Emergency: 1200 lm

The following values are indicated in m

h a b c d

2.5 10.8 4.6 10.8 4.6

3.0 12.1 4.8 12.1 4.8

3.5 12.8 5.0 12.8 5.0

4.0 12.8 5.2 12.8 5.2

Article number Type of installation

Type Lamp/wattage Control 1 (.71)

TwIn‑Control

(.72)

SIngLE‑Control

(.81)

DUo‑Control

(.82)

Dimensions

671958.96X.1.y wall (surface), Ceiling (surface) PMMA 1 x TC‑DEL 18 w • • • • D 305, H 115

671958.96X.2.y wall (surface), Ceiling (surface) PC 1 x TC‑DEL 18 w • • • • D 305, H 115

671959.95X.1.y wall (surface), Ceiling (surface) PMMA 1 x TC‑DEL 26 w • • • • D 305, H 115

671959.95X.2.y wall (surface), Ceiling (surface) PC 1 x TC‑DEL 26 w • • • • D 305, H 115

Series: Flat Polymero® PMMA and PC

Type of protection: IP 43 Ceiling (surface), IP 44 wall (surface) Protection class: I Voltage: 220 ‑ 240 V / 0 Hz, 50 ‑ 60 Hz

For escape route illumination

Base: plastic; diffuser: plastic (PMMA) or plastic (polycarbonate), opal; diffuser fastening: spring system.

Ballast: EB

Available colour (X): 2 = white

Planning guide: Escape route illumination in accordance with EN 1838

E = 1 lx along the centre line

D

H

Ø

100

50205

Ø305Ø262

Ø5

h

d c b

a

Page 226: Emergency Lighting A1

224

EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy

wall (surface), Ceiling (surface)

Flat Basic Type of protection: IP 43 (Ceiling (surface)), IP 44 (Wall (surface))

- Design continuity to the general lighting programme. We offer an extensive range of emergency lighting and general lighting systems. As such, we can provide our customers with integrated solutions for all areas of application, depending on their construction projects.

- A design that fits well with modern architecture

- Low maintenance costs

- Compact design

- Easy to install

- Spring system or bayonet fixing allow for smooth attachment and removal of diffuser - without tools

Page 227: Emergency Lighting A1

225

EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy

For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration

wall (surface), Ceiling (surface) D 300 wall (surface), Ceiling (surface) D 370 wall (surface), Ceiling (surface) D 420 wall (surface), Ceiling (surface) D 500

Accessories | Decorative rings, metal, for series: Flat BasicAvailable colours decorative ring, painted (Z): 2 = white, 61 = ultramarine blue, 76 = rape yellow, 82 = ruby red, 9 = light grey. other RAL colours available on request

Available colours: Decorative ring, metallised (Z): 4 = chrome, 42 = nickel, matt, 5 = brass

Decorative rings, metalDecorative ring D 320 mm, for glass D 300 mm981098.00Z D 320, H 10Decorative ring D 390 mm, for glass D 370 mm981129.00Z D 390, H 10Decorative ring D 440 mm, for glass D 420 mm981100.00Z D 440, H 10

Spacing table 671954.842

Lamp luminous flux:

Mains: 1200 lm, Emergency: 1200 lm

The following values are indicated in m

h a b c d

2.5 12.7 5.4 12.7 5.4

3.0 13.4 5.7 13.4 5.7

3.5 14.5 6.1 14.5 6.1

4.0 15.6 6.3 15.6 6.3

Spacing table 671956.952

Lamp luminous flux:

Mains: 1800 lm, Emergency: 1800 lm

The following values are indicated in m

h a b c d

2.5 14.3 6.1 14.3 6.1

3.0 15.4 6.5 15.4 6.5

3.5 16.0 6.9 16.0 6.9

4.0 17.0 7.3 17.0 7.3

Spacing table 671957.002

Lamp luminous flux:

Mains: 4400 lm, Emergency: 4400 lm

The following values are indicated in m

h a b c d

2.5 16.5 7.3 16.5 7.3

3.0 19.2 7.9 19.2 7.9

3.5 20.2 8.4 20.2 8.4

4.0 20.7 8.8 20.7 8.8

Spacing table 671953.922

Lamp luminous flux:

Mains: 900 lm, Emergency: 900 lm

The following values are indicated in m

h a b c d

2.5 11.4 4.9 11.4 4.9

3.0 12.5 5.2 12.5 5.2

3.5 13.7 5.5 13.7 5.5

4.0 14.5 5.7 14.5 5.7

Spacing table 671955.952

Lamp luminous flux:

Mains: 1800 lm, Emergency: 1800 lm

The following values are indicated in m

h a b c d

2.5 14.3 6.1 14.3 6.1

3.0 15.4 6.5 15.4 6.5

3.5 16.0 6.9 16.0 6.9

4.0 17.0 7.3 17.0 7.3

Article number Type of installation

Lamp/wattage Control 1 (.71)

TwIn‑Control

(.72)

SIngLE‑Control

(.81)

DUo‑Control

(.82)

Dimensions

671953.92X.y wall (surface), Ceiling (surface) 1 x TC‑DEL 13 w – – – – D 300, H 106

671955.95X.y wall (surface), Ceiling (surface) 1 x TC‑DEL 26 w • • • • D 370, H 118

671956.95X.y wall (surface), Ceiling (surface) 1 x TC‑DEL 26 w • • • • D 420, H 124

671954.84X.y wall (surface), Ceiling (surface) 1 x TC‑TEL 18 w – – – – D 300, H 106

671957.00X.y wall (surface), Ceiling (surface) 1 x T16‑R 55 w • • • • D 500, H 150

Series: Flat Basic

Type of protection: IP 43 Ceiling (surface), IP 44 wall (surface) Protection class: I Voltage: 220 ‑ 240 V / 0 Hz, 50 ‑ 60 Hz

For escape route illumination

Base: plastic, white; diffuser: mouth‑blown opal glass, satin finish; glass fastening: spring system or bayonet fixing.

Ballast: EB

Available colour (X): 2 = white

Planning guide: Escape route illumination in accordance with EN 1838

E = 1 lx along the centre line

D

H

Ø

D

H

Ø

D

H

Ø

D

H

Ø

170

Ø201300

26Ø5

R76

100

50205

Ø262370

Ø5

100

50205

Ø262420

Ø5

52Ø280

Ø38058

Ø5

Ø50048

1

2

3x120°

h

d c b

a

Page 228: Emergency Lighting A1

226

EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy

Flat Polymero® Rechteck Type of protection: IP 40

- Design continuity to the general lighting programme. We offer an extensive range of emergency lighting and general lighting systems. As such, we can provide our customers with integrated solutions for all areas of application, depending on their construction projects.

- Design matches modern architectural styles

- Very large viewing distance with motifs

- Flat design

- Luminaire can be opened without tools

wall (surface) wall (surface), Ceiling (surface)

Page 229: Emergency Lighting A1

227

EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy

For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration

wall (surface), Ceiling (surface)

Spacing table 671979.752

Lamp luminous flux:

Mains: 2000 lm, Emergency: 2000 lm

The following values are indicated in m

h a b c d

2.5 13.6 5.6 13.6 5.6

3.0 13.7 6.0 13.7 6.0

3.5 14.9 6.3 14.9 6.3

4.0 16.0 6.5 16.0 6.5

Spacing table 671978.752

Lamp luminous flux:

Mains: 1350 lm, Emergency: 1350 lm

The following values are indicated in m

h a b c d

2.5 11.4 4.9 11.4 4.9

3.0 12.5 5.2 12.5 5.2

3.5 13.7 5.5 13.7 5.5

4.0 14.5 5.7 14.5 5.7

Article number Type of installation

Luminous flux factor

Lamps Mains/

Emergency

Lamp/wattage Control 1 (.71)

TwIn‑Control

(.72)

SIngLE‑Control

(.81)

DUo‑Control

(.82)

Dimensions

671978.75X.y wall (surface), Ceiling (surface) 50 m 2 / 1 2 x T16 (T5) 14 w • • • • L 600, B 320, H 75

671979.75X.y wall (surface), Ceiling (surface) 50 m 2 / 1 2 x T16 (T5) 24 w • • • • L 600, B 320, H 75

Series: Flat Polymero® Rechteck

Type of protection: IP 40 Protection class: I Voltage: 220 ‑ 240 V / 0 Hz, 50 ‑ 60 Hz Viewing distance: 50 m

For escape route identification (only in case of wall installation) or escape route illumination.

Base: metal, powder‑coated. Diffuser: plastic (PMMA), opal. Diffuser fastening: sash lock, plastic.

Please quote symbol number when ordering escape route motifs!

Ballast: EB

Available colour (X): 2 = white

Planning guide: Escape route illumination in accordance with EN 1838

E = 1 lx along the centre line

50 m

L

B H

48 306245320

581

530600

Ø5,5

h

d c b

a

Page 230: Emergency Lighting A1

228

EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy

Rounded® extra flat Type of protection: IP 54

- Design continuity to the general lighting programme. We offer an extensive range of emergency lighting and general lighting systems. As such, we can provide our customers with integrated solutions for all areas of application, depending on their construction projects.

- Fits well with modern architecture

- Housing made of top quality die-cast aluminium

- Low maintenance costs

- Compact design

- Easy to install

- Flat design

- IP 54 type of protection - dustproof and protected against water spray

wall (surface), Ceiling (surface) wall (semi‑recessed)

Page 231: Emergency Lighting A1

229

EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy

For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration

Series: Rounded® extra flat

Type of protection: IP 54 Protection class: I Voltage: 220 ‑ 240 V / 0 Hz, 50 ‑ 60 Hz

For escape route illumination

Base: die‑cast aluminium, powder‑coated. Diffuser: glass, opal, mouth‑blown, satin finish, or plastic (polycarbonate), opal.

Ballast: EB

Available colours (X): 2 = white, 31 = anthracite metallic, 4 = silver metallic

wall (surface), Ceiling (surface) wall (semi‑recessed)

Plastic moulded housing981095.000

Spacing table 671965.95X, 671967.95X und 671971.95X

Lamp luminous flux:

Mains: 1800 lm, Emergency: 1800 lm

The following values are indicated in m

h a b c d

2.5 12.2 5.2 12.2 5.2

3.0 12.9 5.5 12.9 5.5

3.5 13.9 5.8 13.9 5.8

4.0 15.0 6.1 15.0 6.1

Spacing table 671964.96X und 671966.96X

Lamp luminous flux:

Mains: 1200 lm, Emergency: 1200 lm

The following values are indicated in m

h a b c d

2.5 10.6 4.5 10.6 4.5

3.0 11.7 4.8 11.7 4.8

3.5 12.8 5.1 12.8 5.1

4.0 12.4 5.2 12.4 5.2

Spacing table 671968.96X und 671970.96X

Lamp luminous flux:

Mains: 1200 lm, Emergency: 1200 lm

The following values are indicated in m

h a b c d

2.5 10.6 4.5 10.6 4.5

3.0 11.7 4.8 11.7 4.8

3.5 12.8 5.1 12.8 5.1

4.0 12.4 5.2 12.4 5.2

Article number Type of installation

Viewing distance

Type Lamp/wattage Control 1 (.71)

TwIn‑Control

(.72)

SIngLE‑Control

(.81)

DUo‑Control

(.82)

Dimensions

671968.96X wall (surface), Ceiling (surface) ‑ glass 1 x TC‑DEL 18 w ‑ ‑ ‑ ‑ D 270, H 110

671970.96X wall (surface), Ceiling (surface) ‑ PC 1 x TC‑DEL 18 w ‑ ‑ ‑ ‑ D 270, H 110

671969.95X wall (surface), Ceiling (surface) ‑ glass 1 x TC‑DEL 26 w ‑ ‑ ‑ ‑ D 270, H 110

671971.95X wall (surface), Ceiling (surface) ‑ PC 1 x TC‑DEL 26 w ‑ ‑ ‑ ‑ D 270, H 110

671964.96X wall (semi‑recessed) ‑ glass 1 x TC‑DEL 18 w ‑ ‑ ‑ ‑ D 270, H 80, HE 22

671966.96X wall (semi‑recessed) ‑ PC 1 x TC‑DEL 18 w ‑ ‑ ‑ ‑ D 270, H 80, HE 22

671965.95X wall (semi‑recessed) ‑ glass 1 x TC‑DEL 26 w ‑ ‑ ‑ ‑ D 270, H 80, HE 22

671967.95X wall (semi‑recessed) ‑ PC 1 x TC‑DEL 26 w ‑ ‑ ‑ ‑ D 270, H 80, HE 22

Planning guide: Escape route illumination in accordance with EN 1838

E = 1 lx along the centre line

D H

Ø237

HE

D H

Ø258

80

75

170

Ø270

Ø6

22Ø258

80

75

170

Ø270

Ø235Ø6

h

d c b

a

Page 232: Emergency Lighting A1

230

EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy

Alu-Lux oval

Alu-Rund

Type of protection: IP 54

- Design continuity to the general lighting programme. We offer an extensive range of emergency lighting and general lighting systems. As such, we can provide our customers with integrated solutions for all areas of application, depending on their construction projects.

- Modern design

- Housing made of sturdy die-cast aluminium

- Low maintenance costs

- Compact design

- Easy to install

- With glass cover

wall (surface), Ceiling (surface) wall (surface), Ceiling (surface)

Page 233: Emergency Lighting A1

231

EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy

For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration

Series: Alu‑Lux oval

Type of protection: IP 54 Protection class: I Voltage: 220 ‑ 240 V / 0 Hz, 50 ‑ 60 Hz

For escape route illumination

Base: die‑cast aluminium, powder‑coated. glass: frosted inside.

Ballast: EB

Available colours (X): 2 = white, 3 = black

wall (surface), Ceiling (surface) wall (surface), Ceiling (surface)

Series: Alu‑Rund

Type of protection: IP 54 Protection class: I Voltage: 220 ‑ 240 V / 0 Hz, 50 ‑ 60 Hz

For escape route illumination

Base: die‑cast aluminium, powder‑coated. glass: frosted inside.

Ballast: EB

Available colours (X): 2 = white, 3 = black

Spacing table 671963.96X

Lamp luminous flux:

Mains: 1200 lm, Emergency: 1200 lm

The following values are indicated in m

h a b c d

2.5 12.9 5.5 12.7 5.5

3.0 13.1 5.9 14.8 5.8

3.5 14.0 6.1 14.2 6.0

4.0 15.2 6.3 15.1 6.1

Spacing table 671972.92X

Lamp luminous flux:

Mains: 900 lm, Emergency: 900 lm

The following values are indicated in m

h a b c d

2.5 12.3 5.2 12.3 5.2

3.0 13.7 5.4 13.7 5.4

3.5 13.3 5.6 13.3 5.6

4.0 14.5 5.7 14.5 5.7

Spacing table 671973.96X

Lamp luminous flux:

Mains: 1200 lm, Emergency: 1200 lm

The following values are indicated in m

h a b c d

2.5 14.2 5.7 14.2 5.7

3.0 14.3 6.0 14.3 6.0

3.5 15.9 6.3 15.9 6.3

4.0 15.2 6.5 15.2 6.5

Article number Type of installation

Type Lamp/wattage Control 1 (.71)

TwIn‑Control

(.72)

SIngLE‑Control

(.81)

DUo‑Control

(.82)

Dimensions

671963.96X wall (surface), Ceiling (surface) Alu‑Lux oval 1 x TC‑DEL 18 w ‑ ‑ ‑ ‑ L 280, B 160, H 140

671972.92X wall (surface), Ceiling (surface) Alu‑Rund 1 x TC‑DEL 13 w ‑ ‑ ‑ ‑ D 240, H 130

671973.96X wall (surface), Ceiling (surface) Alu‑Rund 1 x TC‑DEL 18 w ‑ ‑ ‑ ‑ D 240, H 130

Planning guide: Escape route illumination in accordance with EN 1838

E = 1 lx along the centre line

L

H

B

45

30

175285

30

Ø5

165

D H

4530

1565

40

Ø240

Ø5

h

d c b

a

Page 234: Emergency Lighting A1

232

EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy

wall (surface)

Light Case Type of protection: IP 54

- Design continuity to the general lighting programme. We offer an extensive range of emergency lighting and general lighting systems. As such, we can provide our customers with integrated solutions for all areas of application, depending on their construction projects.

- Modern design

- Low maintenance costs

- Ball impact protection in acc. with DIN 18032

- Easy to install

- Ballasts incorporated

Page 235: Emergency Lighting A1

233

EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy

For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration

wall (surface)

Spacing table 671974.813

Lamp luminous flux:

Mains: 2400 lm, Emergency: 2400 lm

The following values are indicated in m

h a b c d

2.5 7.7 3.5 10.5 4.9

3.0 9.0 3.9 12.5 5.6

3.5 10.0 4.4 13.9 6.0

4.0 11.0 4.7 15.3 6.6

Article number Type of installation

Lamp/wattage Control 1 (.71)

TwIn‑Control

(.72)

SIngLE‑Control

(.81)

DUo‑Control

(.82)

Dimensions

671974.81X.y wall (surface) 1 x TC‑TEL 32 w • • • • L 230, B 230, H 150

Series: Light Case

Type of protection: IP 54 Protection class: I Voltage: 220 ‑ 240 V / 0 Hz, 50 ‑ 60 Hz

For escape route illumination

Housing: sheet steel, powder‑coated. Removable frame: aluminium, powder‑coated. Safety glass: transparent. Hinges: stain‑less steel. Two cable inlets for through‑wiring, cable diameter 7‑10 mm. Luminaire equipment installed. Ball impact protected in accordance with DIn 18032.

Ballast: EB

Available colour (X): 3 = black

Planning guide: Escape route illumination in accordance with EN 1838

E = 1 lx along the centre line

B

H

L

230

47

230

60

130

130

Ø6

h

d c b

a

Page 236: Emergency Lighting A1

234

EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy

wall (surface), Ceiling (surface)

Weatherproof battens Type of protection: IP 65

- IP 65 type of protection - dustproof and protected against water jets from all directions

- Industrial design

- Lamp replacement without tools

Page 237: Emergency Lighting A1

235

EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy

For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration

Accessories | Protective tubes for weatherproof battens

Replacement diffuser, plastictransparent981441.000 L 1170, D 38 for T26 36 w981442.000 L 1470, D 38 for T26 58 w

Spacing table 671616.759

Lamp luminous flux:

Mains: 3350 lm, Emergency: 3350 lm

The following values are indicated in m

h a b c d

2.5 13.9 6.0 23.0 9.5

3.0 15.6 6.6 23.5 10.0

3.5 16.3 7.0 25.9 10.5

4.0 17.9 7.4 27.4 10.9

Spacing table 671617.759

Lamp luminous flux:

Mains: 5400 lm, Emergency: 5400 lm

The following values are indicated in m

h a b c d

2.5 15.7 6.8 26.3 11.1

3.0 17.3 7.4 28.3 11.8

3.5 18.9 8.0 31.4 12.4

4.0 20.3 8.5 32.2 13.0

Article number Type of installation

Lamp/wattage Control 1 (.71)

TwIn‑Control

(.72)

SIngLE‑Control

(.81)

DUo‑Control

(.82)

Dimensions

671616.75X.y wall (surface), Ceiling (surface) 1 x T26 (T8) 36 w • • • • L 1258, B 56, H 122

671617.75X.y wall (surface), Ceiling (surface) 1 x T26 (T8) 58 w • • • • L 1558, B 56, H 122

Series: Weatherproof battens

Type of protection: IP 65 Protection class: I, II Voltage: 220 ‑ 240 V / 0 Hz, 50 ‑ 60 Hz

For escape route illumination

Housing: plastic, grey. Lamp: open beam. Integrated EB.

Ballast: EB

Available colour (X): 9 = grey

wall (surface), Ceiling (surface) 36 w wall (surface), Ceiling (surface) 58 w

Planning guide: Escape route illumination in accordance with EN 1838

E = 1 lx along the centre line

H

BL

H

BL

62

740

1258

Ø10

62

1050

1558

Ø10

h

d c b

a

Page 238: Emergency Lighting A1

236

EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy

Alu-Druckguss (die-cast aluminium) Type of protection: IP 66

- Design continuity to the general lighting programme. We offer an extensive range of emergency lighting and general lighting systems. As such, we can provide our customers with integrated solutions for all areas of application, depending on their construction projects.

- Modern design

- Housing made of top quality die-cast aluminium

- Low maintenance costs

- Compact design

- Easy to install

Recessed wall installation, antiglare Recessed wall installation, with diffuser

Page 239: Emergency Lighting A1

237

EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy

For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration

Series: Alu‑Druckguss (die‑cast aluminium)

Type of protection: IP 66 Protection class: I Voltage: 220 ‑ 240 V / 0 Hz, 50 ‑ 60 Hz

For escape route illumination

Housing and frame: die‑cast alumi‑nium, powder‑coated. Cover: plastic, opal, shockproof.

Ballast: EB

Available colours (X): 2 = white, 3 = black, 9 = grey

Series: Alu‑Druckguss (die‑cast aluminium)

Type of protection: IP 66 Protection class: I Voltage: 220 ‑ 240 V / 0 Hz, 50 ‑ 60 Hz

For escape route illumination

Housing and frame: die‑cast alumi‑nium, powder‑coated. Cover: plastic, opal, shockproof.

Ballast: EB

Available colours (X): 2 = white, 3 = black, 9 = grey

Recessed wall installation Recessed wall installation

Housing for recessed wall and step luminaires Recess opening: LA 232 x BA 92 mm, max. wall thickness: 20 mm90‑2780

Moulded housing for installation in concrete walls 64253.000

Article number Type of installation

Type Lamp/wattage Control 1 (.71)

TwIn‑Control

(.72)

SIngLE‑Control

(.81)

DUo‑Control

(.82)

Dimensions

671975.91X Recessed wall installation antiglare 1 x TC‑EL 9 w ‑ ‑ ‑ ‑ L 236, B 100, H 5

LA 228 x BA 85, HE 70

671976.91X Recessed wall installation with diffuser 1 x TC‑EL 9 w ‑ ‑ ‑ ‑ L 236, B 100, H 5

LA 228 x BA 85, HE 70

BBA

L

LA

HE

H

B

L

LA

BA

HE

H

85

228236

100 85

228236

100

Page 240: Emergency Lighting A1

238

EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy

wall (recessed) (solid wall)

Recessed LED step luminaire for installation in concrete steps Type of protection: IP 66

- Design continuity to the general lighting programme. We offer an extensive range of emergency lighting and general lighting systems. As such, we can provide our customers with integrated solutions for all areas of application, depending on their construction projects.

- Modern design

- Housing made of top quality die-cast aluminium

- Low maintenance costs

- Compact design

- Easy to install

Page 241: Emergency Lighting A1

239

EMERgEnCy LIgHTIng | LUMInAIRES FoR CEnTRAL EMERgEnCy PowER SUPPLy

For connecting diagrams, see pages 119 ‑ 121 | Catalogue number explanations: see page 276Tender texts available upon request | Specifications subject to alteration

wall (recessed) (solid wall)

Series: Recessed LED step luminaire for installation in concrete steps

Type of protection: IP 66 Protection class: I with EB, III without EB Voltage: 220 ‑ 240 V / 0 Hz, 50 ‑ 60 Hz

For escape route illumination

Housing: sheet steel, galvanised. Cover: polycarbonate, transparent. Lamellar cover: die‑cast zinc, powder‑coated. The luminaire housing is used as the moulded housing. During installation, the LED module must be removed from the luminaire housing.Two cable inlets with sleeves for M32 armoured cable (outer sleeve Ø: 24.5 mm, inner Ø: 21 mm).

LED module with electronic ballast (connected load: 10 w). The max. connected load of the EB must not be exceeded!

Prepared for through‑wiring.

Ballast: EB

Available colours (X): 31 = anthracite metallic, 4 = silver metallic

Article number Type of installation

Type Lamp/wattage Control 1 (.71)

TwIn‑Control

(.72)

SIngLE‑Control

(.81)

DUo‑Control

(.82)

Dimensions

671977.00X wall (recessed) (solid wall) with EB 1 x LED 1,92 w ‑ ‑ ‑ ‑ L 210, B 90, H 5

LA 190 x BA 70, HE 110

671980.00X wall (recessed) (solid wall ) without EB 1 x LED 1,92 w ‑ ‑ ‑ ‑ L 210, B 90, H 5

LA 190 x BA 70, HE 110

B

LAL

BA

HE

H

70

25

190

122,5

110

Page 242: Emergency Lighting A1

240

Page 243: Emergency Lighting A1

241

Standards and regulations

European and international regulations

EN 1838 Emergency lighting 242 - 243

EN 50172 Emergency escape lighting systems 244

EN 50171 Central power supply systems 245

EN 50272-2 Stationary batteries 245

EN 60598-2-22 Particular requirements 246 Luminaires for emergency lighting

German regulations

VDE 0108, Part 100, Emergency lighting 246

DIN 4844 -1 Safety signs 262 Viewing distances

DIN 4844 -2 Safety signs 262 Sign design

VDE 0100, Part 560, Systems with nominal voltages of 263 up to 1,000 V

VDE 0100, Part 718, Buildings for gatherings of people 263

(M)LAR (Model) Wiring systems directive 264

Special building directives 264

ASR Workplace directives 265

BGV Safe working practices regulations 262

Planning 268 - 269

Exclusion of liability

RZB shall not be liable for any loss or damage attributable to any application of, or failure to apply, any information supplied herein. Excerpts from the aforementioned standards and regulations are provided for information purposes only. Other local building regulations may apply.

Inasmuch as the applicable requirements, standards and regulations are subject to change, the relevant original versions of such standards and regulations must be applied in each case.

Page 244: Emergency Lighting A1

242

p

d

EuROPEAN AND INtERNAtIONAL REGuLAtIONS

Specifications subject to alteration

Definition of “emergency lighting”

Viewing distances Legend

Safety signs for escape routes must comply with the following requirements:

• Viewing distance (d): formula: d= s x p

p = sign height

s = distance factor 100 (externally illuminated signs) and distance factor 200 (internally lit signs)

Safety signs for escape routes must comply with the following requirements:

the ratio of white colour to green colour luminance must be between 5:1 and 15:1.

the ratio of maximum to minimum luminance shall be less than 10:1 for each colour.

Luminance:

the minimum luminance of any green area (safety colour) on the sign must be greater than 2 cd/square meters.

Example:

Calculation of an internally lit sign’s height for a required viewing distance of 30 m (d = 30)

Applicable equation:

d = s x p p = d / s

p = 30 / 200 = 0.15 m (sign height)

Emergency lighting

Emergency escape lighting Standby lighting

Escape route lighting Anti-panic lighting (Open area lighting)

High risk task area lighting

Contrast colourSafety colour

EN 1838 – EMERGENCY LIGHtING

Page 245: Emergency Lighting A1

243

EuROPEAN AND INtERNAtIONAL REGuLAtIONS

Specifications subject to alteration

Specific locations where a luminaire must be provided

at each mandatory exit door

near* stairs so that each staircase step receives direct light

near* any other change of floor level

near* each mandatory safety sign

at each change of direction

at each intersection of corridors

outside and near* each final exit

near* each first aid post

near* each piece of fire fighting equipment and call point

*Note:the term “near” means within 2 meters.First aid posts, fire fighting equipment and call points that are located outside the escape route must be illuminated with a minimum of 5 lux.

EN 1838 – EMERGENCY LIGHtING

Page 246: Emergency Lighting A1

244

EuROPEAN AND INtERNAtIONAL REGuLAtIONS

Specifications subject to alteration

General

the purpose of emergency escape lighting is to ensure that lighting is provided promptly, automatically and for a suitable time in a specific area during a power failure.

the installation is to be realized in such a way that emergency escape lighting accomplishes the following (among other things):

- illuminates escape route signs;

- illuminates escape routes leading to emergency exits;

- ensures that fire alarm call points and fire equipment provided along escape routes can be readily located and used (if required);

- etc.

Emergency escape lighting is to be activated not only on complete failure of the supply to the general lighting but also in the event of a final-circuit failure.

Emergency escape lighting is not designed to enable normal work to be continued on the premises in the event of failure of normal or standby lighting.

For details concerning illuminance levels and measurement, see EN 1838.

Visibility

In locations where building occupants (a) do not have a clear and unobstructed view of an exit sign and/or (b) may have doubts as to the location of an emergency exit, a directional sign (or series of signs) is to be provided in such a way that a person moving toward such sign will be directed to an emergency exit.

An exit or directional sign is to be clearly visible at all points along the escape route.

All signs marking exits and / or escape routes are to be uniform in colour and format, and their luminance is to comply with EN 1838.

Maintained exit signs must be installed for applications where occupants may be unfamiliar with the building.

Anti-panic lighting (Open area lighting)

the purpose of open area (anti-panic) lighting is to reduce the likelihood of panic and to enable safe movement of occupants toward escape routes.

Such lighting is used in areas with undefined escape routes. Such areas may include halls or premises exceeding 60 square meters in size, or smaller areas if there is an additional hazard such as use by a large number of people.

Log book

A log book is to be kept on the premises in the care of a responsible person appointed by the occupant/owner and is to be readily available for examination by any duly authorized person.

the log book is to be used to record the following information:

- date of commissioning of the system including any certificate relating to changes;

- date of each periodic inspection and test;

- dates and brief details of any maintenance, inspection and test;

- dates and brief details of any defects and of remedial action taken;

- date and brief details of any change in the emergency lighting installation;

- if any automatic testing device is employed, the main characteristics and mode of operation of that device are to be described.

Maintenance and testing

Daily:

Indicators of the central power supply are to be visually inspected for correct operation.

Monthly:

If automatic testing devices are used, the results of the function tests are to be recorded.

Monthly tests are to be carried out as follows:

- a) Switch on in the emergency mode each luminaire and each internally illuminated exit sign via its battery by simulation of a failure of the supply to the general lighting for a period sufficient to ensure that each lamp is illuminated.

- During this period, all luminaires and signs are to be checked to ensure that they are present, clean and functioning correctly.

- At the end of this test period, the power supply to the general lighting is to be restored and any indicator lamp or device is to be checked to ensure that it shows that the normal supply has been restored.

In addition to a), for central battery systems, the correct operation of system monitors is to be checked.

Annually:

If automatic testing devices are used, the results of the full rated duration test are to be recorded.

A monthly inspection is be carried out for all other systems, whereby the following additional tests are to be carried out:

- each luminaire and internally illuminated sign is to be tested for its full rated duration in accordance with the manufacturer‘s recommendations;

- the power supply for general lighting is to be restored and any indicator lamp or device is to be checked to ensure that it is showing that normal supply has been restored. the charging arrangements should be checked for proper functioning;

- the date of the test and its results are to be recorded in the system log book.

EN 50172 – EMERGENCY ESCAPE LIGHtING SYStEMS

Page 247: Emergency Lighting A1

245

EuROPEAN AND INtERNAtIONAL REGuLAtIONS

Specifications subject to alteration

Battery chargers must be capable of automatically charging the associated battery that has been discharged so that it can perform at least 80% of the specified duration at the rated load within 12 h.

Central Power Supply (CPS)

Central power supply without any restriction in respect to rated output power.

Ventilation

Batteries are to be installed in well ventilated rooms and cabinets. the minimum cross section of the ventilation opening is to correspond to battery capacity.

Such openings need to be adequately positioned to allow for optimum air exchange (e.g. in opposite walls).

Batteries are to be located at least 2 m from wall openings.

Exhaust air must be discharged outside the building.

Location

Batteries are to be installed in protected rooms, if required, electrical or closed electrical operating rooms are to be provided.

the batteries may be kept:

- in special rooms on the premises

- in specific separate areas on the premises

- in enclosures or cabinets on or off the premises

- in battery compartments that are integrated into devices (twin housing)

Specific requirements for battery rooms

the floor must be rated for the battery weight, and allowance is to be made for the possibility that additional batteries (and hence weight) will be installed down the line.

If only authorized personnel are allowed to access to battery rooms, the doors are to be equipped with anti-panic locks.

the floors used for sealed batteries are to be electrolyte resistant. If this is not the case, the batteries are to be placed in acid drip pans.

the floor area for a person standing within arm’s reach of the battery is to be electrostatic dissipative in order to prevent electrostatic charge generation.

Ventilation must comply with EN 50272 and the exhaust air must be discharged outside the building.

Low Power Supply (LPS)

Central power supply with a limited rated output power:

- 3 h = 500 W

- 1h = 1, 500 W

Information and warning signs

Appropriate information and warning signs (pursuant to EN 50272 section 12.1) need to be posted in battery rooms.

Documentation

Documentation containing the following information must be available near the battery:

- Name of manufacturer or vendor

- Name of installer

- Date of commissioning

- Manufacturer’s or vendor’s type designation

- Nominated voltage of battery

- Nominal capacity with indication of discharge time

- Safety recommendations

- Recommendations for operating and maintenance

- Information regarding disposal and recycling

Such documentation must be at all maintenance and operating personnel’s disposal.

Inspections

Batteries and their operation conditions have to be checked at regular intervals for correct operation and safety.

During such inspections and controls it must be verified whether the following items conform with the manufacturer’s specifications:

- Voltage set for the battery charger

- Voltage of battery cells/blocks

- Electrolyte density and level (if applicable)

- Cleanliness

- tightness

- Battery connector position (if required)

- Ventilation

- Plugs and valves

- Battery temperature

EN 50171 – CENtRAL POWER SuPPLY SYStEMS

EN 50272 – StAtIONARY BAttERIES

Page 248: Emergency Lighting A1

246

EuROPEAN AND INtERNAtIONAL REGuLAtIONS

Specifications subject to alteration

In emergency luminaires, fluorescent lamps used to provide emergency lighting are to come on without the aid of glow starters. Such starters are not to be in circuit during emergency mode operation. Emergency lighting shall not be provided by means of fluorescent lamps with built-in glow starters.

Self-contained luminaires must be recharged within 24 hours following discharge.

the ambient temperature of the battery cells should be at least 5°C; however, an occasional temperature drop to 0°C is admissible.

* in accordance with BGV A8

Daily testIndicators for the central power supply are to be visually inspected for correct operation.

Weekly testFunction of emergency lighting is to be checked at least once a week.Connection of the power source for safety purposes is required for battery-powered systems.

Monthly testIf automatic testing devices are used, the results of the function tests are to be recorded.

tests are to be carried out by simulating a general lighting power supply failure.

Yearly testIf automatic testing devices are used, the results of the function tests are to be recorded.the yearly test is not to be activated automatically.

Test at 3 year intervalEvery three years (at the most) emergency lighting illuminance is to be measured as provided in DIN EN 1838.

EN 60598-2-22 – PARtICuLAR REQuIREMENtS / LuMINAIRES FOR EMERGENCY LIGHtING

VDE 0108, PARt 100 – EMERGENCY LIGHtINGIllu

min

ance

Sw

itchi

ng ti

me

Rat

ed d

urat

ion

of p

ower

sou

rce

for s

afet

y pu

rpos

es

Illum

inat

ion

of e

scap

e ro

ute

lum

inai

res,

mai

ntai

ned

Cen

tral b

atte

ry s

yste

m

Gro

up b

atte

ry s

yste

m

Sel

f-co

ntai

ned

lum

inai

res

(as

of

08/2

010)

Pow

er g

ener

atio

n un

it

(with

out i

nter

rupt

ion)

Pow

er g

ener

atio

n un

it (s

witc

hing

tim

e <

0.5

s)

Pow

er g

ener

atio

n un

it (s

witc

hing

tim

e 15

s)

Part

icul

arly

saf

e ne

twor

k

Places of assembly (temporary buildings excluded), theatres, cinemas 1 lx 1s 3 h • • • • • • – –

temporary buildings, used for exhibitions 1 lx 1 s 3 h • • • • • • – –

Exhibition halls 1 lx 1 s 3 h • • • • • • – –

Shops 1 lx 1 s 3 h • • • • • • – –

Restaurants 1 lx 1 s 3h • • • • • • – –

Accomodation facilities, nursing homes

1 lx1 s - 15 s

depending on risk level

8 h (3 h are sufficient, if buttons in accordance with VDE 0108,

part 100, section 4.4.8, are available)

• • • • • • • –

Schools 1 lx1 s - 15 s

depending on risk level

3 h • • • • • • • –

Car-parks, underground parking garages 1 lx 15 s 1 h • • • • • • • –

Airports, railway stations 1 lx 1 s

3 h (depending on the evacuation concept, for above-ground railway station areas 1 h

may be admissible)

• • • • • • – –

Multi-storey buildings 1 lx1 s - 15 s

depending on risk level

3 h ( 8 h for multi-storey residential buildings, if buttons in accordance with VDE 0108, part 100, section

4.4.8, are not available)

• • • • • • • –

Escape routes at workplaces 1 lx 15 s 1 h –* • • • • • • •

High-risk workplaces 15 lx 0.5 s Duration of risk for building occupants • • • • • • – •

Stages 3 lx 1 s 3 h • • • • • • – –

Page 249: Emergency Lighting A1

247

EB NEA < 0,5 sec

1,0 lx

BS

CPS

3,0 lx

LPS

En50%5 sec

60 sec100%

DS3h≤ 1,0 sec

GERMAN REGuLAtIONS

Specifications subject to alteration

Places of assembly, theatres and cinemas (excluding temporary buildings)

Model regulation for places of assembly, June 2005 version

- Places of assembly with assembly rooms, used for the gathering together of 200 or more persons

- Outdoor places of assembly (including performance areas) with capacity for 1,000 or more persons

- Sports stadiums with capacity exceeding 5,000 persons

Please note:

the number of persons is to be calculated as follows:

- for table seating: 1 person per square meter of room floorspace

- for seats arranged in rows and for standing room: 2 persons per square meter of room floorspace

- for standing room on bleachers: 2 persons per running meter

- for exhibition rooms: 1 person per square meter of room floorspace

Exceptions:this regulations does not apply to the following:

- rooms used for religious gatherings; school classrooms and exhibition rooms in museums.

Definition:

In places of assembly an emergency escape lighting system must be installed that allows for safe termination of operations on stages and in performance areas, and safe escape of members of the public and staff, even in case of total failure of general lighting.

Emergency escape lighting must be provided:

- for staircases, landings, exits and essential corridors

- in assembly rooms as well as in any rooms/areas that are used by visitors such as foyers, cloakrooms, and lavatories

- for stages and performance areas

- in staff rooms larger than 20 square meters of floorspace, office rooms excluded

- in rooms that accommodate electrical equipment or technical building systems, as well as in spotlight and projector rooms

- for outdoor places of assembly and sports stadiums that are used after dark

- for safety signs of exits and escape routes

- for illumination of steps

In assembly rooms that are darkened for operation, on stages and performance areas, non-maintained safety lighting must be installed. Exits, corridors and stairs in these assembly rooms must be recognizable while these rooms are darkened, irrespective of the remaining emergency lighting. An illumination of stairs is not required for the corridors of assembly rooms containing mobile chairs, as well as for sports stadiums with emergency lighting.

Places of assembly, VDE 0108, Part Teil 100

EN 1838

Stages, VDE 0108, Part 100

Important note:

the above are model regulations only. Regional building code regulations may also apply in certain cases.

MODEL BuILDING CODE REGuLAtIONS VDE 0108, PARt 100 – EMERGENCY LIGHtING

See page 260 for symbol legend

Page 250: Emergency Lighting A1

248

EB NEA < 0,5 sec

BS

CPS LPS

DS3h≤ 1,0 sec

1,0 lxEn50%5 sec

60 sec100%

GERMAN REGuLAtIONS

Specifications subject to alteration

Temporary buildings

Model directive concerning the construction, operation and maintenance of temporary buildings (M-FlBauR), May 2007 version

Scope: this directive applies to temporary buildings pursuant to article 76, section 1 of the Model Building Code (MBO).

the provisions of this directive regarding rooms in tents apply also to rooms of similar size that are used for similar purposes in other temporary buildings with more than 200 square meters of floorspace.

Please note:

the number of persons is to be calculated as follows:

- for table seating: 1 person per square meter of room floorspace

- for seats arranged in rows and for standing room: 2 persons per square meter of room floorspace

Exceptions:this directive does not apply to tents used for camping or medical services or for tents with less than 75 square meters of floorspace.

Definition:

Lighting

tents and similar rooms that are used after dark and have more than 200 square meters of floorspace are to be equipped with emergency lighting that conforms with the relevant technical regulations.

the emergency lighting for such rooms is to be illuminated whenever the main lighting is illuminated.

the lighting system is to be powered by the building grid; battery powered luminaires are admissible only if securely installed.

In the event of a general power failure, battery powered luminaires are to be on hand.

Temporary buildings, VDE 0108, Part 100

EN 1838

Important note:

the above are model regulations only. Regional building code regulations may also apply in certain cases.

VDE 0108, PARt 100 – EMERGENCY LIGHtING MODEL BuILDING CODE REGuLAtIONS

See page 260 for symbol legend

Page 251: Emergency Lighting A1

249

EB NEA < 0,5 sec

BS

CPS LPS

DS3h≤ 1,0 sec

1,0 lxEn50%5 sec

60 sec100%

GERMAN REGuLAtIONS

Specifications subject to alteration

Pubs and restaurants

Model regulation for places of assembly (MVStättV), June 2005 version

MVStättV applies to the following: Restaurants whose dining area floorspace exceeds 200 square meters; and pubs and discotheques that have standing room and more than 100 square meters of floorspace.

Please note:

the number of persons is to be calculated as follows:

- for table seating: 1 person per square meter of room floorspace

- for seats arranged in rows and for standing room: 2 persons per square meter of room floorspaces

Exceptions:

none

Definition:

In places of assembly an emergency escape lighting system must be installed that allows for safe termination of operations on stages and in performance areas, and safe escape of members of the public and staff, even in case of total failure of general lighting.

Emergency lighting must be provided:

- for staircases, landings, exits and essential corridors

- in assembly rooms as well as in any rooms/areas that are used by visitors such as foyers, cloakrooms, and lavatories

- for stages and performance areas

- in staff rooms larger than 20 square meters of floorspace, office rooms excluded

- in rooms that accommodate electrical equipment or technical building systems, as well as in spotlight and projector rooms

- for outdoor places of assembly and sports stadiums that are used after dark

- for safety signs of exits and escape routes

- for illumination of steps

In assembly rooms that are darkened for operation, on stages and performance areas, non-maintained safety lighting must be installed. Exits, corridors and stairs in these assembly rooms must be recognizable while these rooms are darkened, irrespective of the remaining emergency lighting. An illumination of stairs is not required for the corridors of assembly rooms containing mobile chairs, as well as for sports stadiums with emergency lighting.

Restaurants, VDE 0108, Part 100

EN 1838

Important note:

the above are model regulations only. Regional building code regulations may also apply in certain cases.

MODEL BuILDING CODE REGuLAtIONS VDE 0108, PARt 100 – EMERGENCY LIGHtING

See page 260 for symbol legend

Page 252: Emergency Lighting A1

250

EB NEA < 15 sec

1,0 lx

BS

CPS LPS

En50%5 sec

60 sec100%

DS8hje nach Panikrisiko oder Gefährdungsbeurteilung

1 - 15 sec

GERMAN REGuLAtIONS

Specifications subject to alteration

Multi-storey buildings

Model Directive concerning the construction, operation and maintenance of multi-storey buildings (M-HHR), April 2008 version

Special requirements and variances pursuant to article 51, section 1 of the Model Building Code (MBO) for the construction and operation of multi-storey buildings (paragraph 2, section 4, no. 1 of MBO) are provided herein.

Multi-storey buildings are buildings whose height exceeds 22 meters.

Exceptions:

Emergency escape lighting time can be reduced to 3 hours if the lighting is timer-controlled and switched via master lighting switches.

Definition:

Emergency escape lighting

the emergency escape lighting system in multi-storey buildings must automatically switch on in the event of a general lighting failure.

Emergency escape lighting must be provided:

- on escape routes

- in front of lifts

- for safety signs on escape routes

Multi-storey building, VDE 0108, Part 100

EN 1838

Important note:

the above are model regulations only. Regional building code regulations may also apply in certain cases.

VDE 0108, PARt 100 – EMERGENCY LIGHtING MODEL BuILDING CODE REGuLAtIONS

See page 260 for symbol legend

Page 253: Emergency Lighting A1

251

EB NEA < 15 sec

1,0 lx

BS

CPS LPS

En50%5 sec

60 sec100%

DS8hje nach Panikrisiko oder Gefährdungsbeurteilung

1 - 15 sec

GERMAN REGuLAtIONS

Specifications subject to alteration

Accomodation facilities and nursing homes

Model regulation regarding the construction, operation and maintenance of accomodation facilities (MBeVO).

the provisions of this regulation apply to accomodation facilities with more than 12 guest beds.

Please note:

Emergency escape lighting time can be reduced to 3 hours if the lighting is timer-controlled and switched via master lighting switches.

Exceptions:

this regulation does not apply to holiday apartments.

Definition:

In accommodation facilities emergency escape lighting must be provided:

- in all essential corridors and staircases

- in rooms and landings between essential staircases and exits

- for safety exit signs

- for steps in essential corridors

Accomodation facilities, VDE 0108, Part 100

EN 1838

Important note:

the above are model regulations only. Regional building code regulations may also apply in certain cases.

MODEL BuILDING CODE REGuLAtIONS VDE 0108, PARt 100 – EMERGENCY LIGHtING

See page 260 for symbol legend

Page 254: Emergency Lighting A1

252

EB NEA < 15 sec

BS

CPS LPS

DS3hje nach Panikrisiko oder Gefährdungsbeurteilung

1 - 15 sec

1,0 lxEn50%5 sec

60 sec100%

GERMAN REGuLAtIONS

Specifications subject to alteration

Schools

Model directive regarding building code regulations for schools (MSchulbauR), April 2009 version

this directive applies to requirements pursuant to paragraph 51, section 1 of the Model Building Code (MBO) for general education and vocational schools that are not used solely for adult education classes.

Please note:

Insofar as not otherwise provided by the MSchulbauR directive, the provisions of the MBO building code shall apply. Any workplace safety regulations issued by insurers, trade associations and so on, as well as workplace regulations or regional laws that apply to schools apply.

Exceptions:

this directive does not apply to colleges, universities, academies, adult education centres, music schools, dance schools, driving schools and the like.

Definition:

Emergency escape lighting must be provided in halls that are intersected by escape routes, in essential corridors and staircases as well as in windowless common rooms.

Schools, VDE 0108, Part 100

EN 1838

Important note:

the above are model regulations only. Regional building code regulations may also apply in certain cases.

VDE 0108, PARt 100 – EMERGENCY LIGHtING MODEL BuILDING CODE REGuLAtIONS

See page 260 for symbol legend

Page 255: Emergency Lighting A1

253

EB NEA < 15 sec

BS

CPS LPS

DS1h≤ 15 sec

1,0 lxEn50%5 sec

60 sec100%

GERMAN REGuLAtIONS

Specifications subject to alteration

Car-parks

Regulation regarding the construction, operation and maintenance of car-parks (M-GarVO), May 1993 version (as amended by the resolution of 30 May 2008)

An emergency escape lighting system for the illumination of escape routes must be installed in large enclosed car-parks (excluding large single-level car-parks with regular users).

Large car-parks are car-parks with net floorspace exceeding 1,000 square meters.

Exceptions:

none

Definition:

Open car-parks are car-parks (a) with non-closeable openings that (i) lead directly outside and (ii) whose surface accounts for at least one third of the total surface of the facility’s exterior walls; (b) at least two of whose opposing enclosing walls containing such openings are not more than 70 meters apart; and (d) with continuous cross ventilation.

Small open car-parks are small car-parks with non-closeable openings that (i) lead directly outside and (ii) whose surface accounts for at least one third of the total surface of the facility’s exterior walls.

Closed car-parks are car-parks that do not meet the above criteria.

Car-parks, VDE 0108, Part 100

EN 1838

Important note:

the above are model regulations only. Regional building code regulations may also apply in certain cases.

MODEL BuILDING CODE REGuLAtIONS VDE 0108, PARt 100 – EMERGENCY LIGHtING

See page 260 for symbol legend

Page 256: Emergency Lighting A1

254

EB NEA < 0,5 sec

BS

CPS LPS

DS3h≤ 1,0 sec

1,0 lxEn50%5 sec

60 sec100%

GERMAN REGuLAtIONS

Specifications subject to alteration

Exhibition places

Model regulation for places of assembly (MVStättV), June 2005 version

Places of assembly with assembly rooms, used for the gathering together of 200 or more persons.

Please note:

the number of persons is to be calculated as follows:

- for table seating: 1 person per square meter of room floorspace

- for seats arranged in rows and for standing room: 2 persons per square meter of room floorspace

Exceptions:

Pursuant to number 3 of the MVStättV (places of assembly regulation), only exhibition rooms of museums are excluded from the scope of application.

the above regulation applies, however, to museums with other rooms of assembly pursuant to article 2, no. 3 (i.g. foyer, discussion rooms, cafeteria or the like) which fall within the scope of article 1.

Definition:

In places of assembly an emergency escape lighting system must be installed that allows for safe termination of operations on stages and in performance areas, and safe escape of members of the public and staff, even in case of total failure of general lighting.

Emergency escape lighting must be provided:

- for staircases, landings, exits and essential corridors

- in assembly rooms as well as in any rooms/areas that are used by visitors such as foyers, cloakrooms, and lavatories

- for stages and performance areas

- in staff rooms larger than 20 square meters of floorspace, office rooms excluded

- in rooms that accommodate electrical equipment or technical building systems, as well as in spotlight and projector rooms

- for outdoor places of assembly and sports stadiums that are used after dark

- for safety signs of exits and escape routes

- for illumination of steps

In assembly rooms that are darkened for operation, on stages and performance areas, non-maintained safety lighting must be installed. Exits, corridors and stairs in these assembly rooms must be recognizable while these rooms are darkened, irrespective of the remaining emergency lighting. An illumination of stairs is not required for the corridors of assembly rooms containing mobile chairs, as well as for sports stadiums with emergency lighting.

Exhibition places, VDE 0108, Part 100

EN 1838

Important note:

the above are model regulations only. Regional building code regulations may also apply in certain cases.

VDE 0108, PARt 100 – EMERGENCY LIGHtING MODEL BuILDING CODE REGuLAtIONS

See page 260 for symbol legend

Page 257: Emergency Lighting A1

255

EB NEA < 0,5 sec

BS

CPS LPS

DS3h≤ 1,0 sec

1,0 lxEn50%5 sec

60 sec100%

3,0 lx

GERMAN REGuLAtIONS

Specifications subject to alteration

Stages

Model regulation for places of assembly (MVStättV), June 2005 version)

Places of assembly with assembly rooms, used for the gathering together of 200 or more persons.

Exceptions:

Performance spaces with less than 20 square meters of floorspace are not classified as performance areas.

Definition:

In places of assembly an emergency escape lighting system must be installed that allows for safe termination of operations on stages and in performance areas, and safe escape of members of the public and staff, even in case of total failure of general lighting.

Emergency escape lighting must be provided:

- for staircases, landings, exits and essential corridors

- in assembly rooms as well as in any rooms/areas that are used by visitors such as foyers, cloakrooms, and lavatories

- for stages and performance areas

- in staff rooms larger than 20 square meters of floorspace, office rooms excluded

- in rooms that accommodate electrical equipment or technical building systems, as well as in spotlight and projector rooms

- for outdoor places of assembly and sports stadiums that are used after dark

- for safety signs of exits and escape routes

- for illumination of steps

In assembly rooms that are darkened for operation, on stages and performance areas, non-maintained safety lighting must be installed. Exits, corridors and stairs in these assembly rooms must be recognizable while these rooms are darkened, irrespective of the remaining emergency lighting. An illumination of stairs is not required for the corridors of assembly rooms containing mobile chairs, as well as for sports stadiums with emergency lighting.

Stages, VDE 0108, Part 100

EN 1838

Bühnen VDE 0108 Teil 100

Important note:

the above are model regulations only. Regional building code regulations may also apply in certain cases.

MODEL BuILDING CODE REGuLAtIONS VDE 0108, PARt 100 – EMERGENCY LIGHtING

See page 260 for symbol legend

Page 258: Emergency Lighting A1

256

EB NEA < 0,5 sec

1,0 lx

BS

CPS LPS

En50%5 sec

60 sec100%

DS3h≤ 1,0 sec

GERMAN REGuLAtIONS

Specifications subject to alteration

Points of sale

Model regulation regarding the construction, operation and maintenance of retail outlets (MVkVO)

Shops and shopping malls with more than 2,000 square meters of floorspace

Exceptions:

none

Definition:

In retail outlets, emergency escape lighting must be provided:

- inside shops

- in staircases, landings and shopping streets

- in corridors that are essential for customers

- in staff rooms

- in lavatories with more than 50 square meters of floorspace

- in rooms that accommodate electrical equipment or technical building systems

- for safety exit signs and illumination of steps.

Points of sale, VDE 0108, Part 100

EN 1838

Important note:

the above are model regulations only. Regional building code regulations may also apply in certain cases.

VDE 0108, PARt 100 – EMERGENCY LIGHtING MODEL BuILDING CODE REGuLAtIONS

See page 260 for symbol legend

Page 259: Emergency Lighting A1

257

EB ≤ 15 sec

1,0 lx

BS

CPS LPS

En50%5 sec

60 sec100%

BS1h≤ 15 sec

GERMAN REGuLAtIONS

Specifications subject to alteration

Workplaces

Workplace directive concerning emergency escape lighting (ASR 7/4)

- Escape routes in working areas and storerooms with more than 2,000 square meters of floorspace

- Escape routes in working areas and staff rooms whose floors are more then 22 meters above the ground

- Escape routes located in the following types of areas with more than 100 square meters of floorspace: working areas without windows, skylight or the like; rooms that are kept dark for operational purposes

- Escape routes located in the following types of areas with more than 30 but less than 100 square meters of floorspace: in working areas without windows, skylight or the like; rooms that are kept dark for operational purposes. For such escape routes, luminaires that can be seen from any point are to be installed at all exits.

- Escape routes in potentially explosive or toxic workplaces, as well as in workplaces in which non-sealed radioactive materials are handled, with more than 100 square meters of floorspace

- Escape routes in potentially explosive or toxic working places, as well as in workplaces in which non-sealed radioactive materials are handled, with more than 30 and less than 100 square meters of floorspace. For such escape routes, luminaires that can be seen from any point are to be installed at all exits.

- For escape routes in laboratories with more than 600 square meters of floorspace and where workers are exposed to specific hazards

- For escape routes in laboratories with more than 30 and less than 600 square meters of floorspace and where workers are exposed to specific hazards. For such escape routes, luminaires that can be seen from any point are to be installed at all exits.

Exceptions:

none

Definition:

Escape route lighting

Escape route lighting must allow for safe evacuation by providing sufficient illumination for escape routes and signs.

Illuminance

Escape routes must be lit with a minimum of 1 lux. this value is that measured at the end of the luminaire’s operating time on the horizontal plane located 0.2 meters above floor level or the stairs.

Minimum operating time: 1 hour.

Workplaces, VDE 0108, Part 100

EN 1838

Important note:

the above are model regulations only. Regional building code regulations may also apply in certain cases.

MODEL BuILDING CODE REGuLAtIONS VDE 0108, PARt 100 – EMERGENCY LIGHtING

See page 260 for symbol legend

Page 260: Emergency Lighting A1

258

EB NEA < 0,5 sec

E = 0,1 x Enmindestens aber 15 lx

BS

CPS LPS

En50%5 sec

60 sec100%

DSZeitraum der Gefährdung

≤ 0,5 sec

GERMAN REGuLAtIONS

Specifications subject to alteration

High risk task areas

Workplace directive concerning emergency escape lighting (ASR 7/4)

High risk task area lighting must be provided in places where staff or third parties are exposed to specific hazards, or where accidents are very likely to occur in the event of a general lighting failure.

Please note:

the emergency escape luminaires for particularly hazardous workplaces have to be installed in such a way that the required illuminance values are achieved within the entire area of hazardous risk.

Definition:

General

the technical specifications for high risk task area lighting are determined by the type of activity and room involved.

Illuminance

the illuminance values of high risk task area lighting are determined by nominal illuminance (En) pursuant to workplace directive “ASR 7/3: Artificial lighting” for each type of activity and room.

The illuminance of high risk task area lighting must be E = 0.1 x En, however not less than 15 lux.

this illuminance must continue for the duration of the risk, subject to a one hour minimum.

Delay on startup

the maximum delay on startup for high risk task area lighting is 0.5 seconds.

High-risk workplaces, VDE 0108, Part 100

EN 1838

Important note:

the above are model regulations only. Regional building code regulations may also apply in certain cases.

VDE 0108, PARt 100 – EMERGENCY LIGHtING MODEL BuILDING CODE REGuLAtIONS

See page 260 for symbol legend

Page 261: Emergency Lighting A1

259

EB NEA < 0,5 sec

1,0 lx

BS

CPS LPS

En50%5 sec

60 sec100%

DS3h≤ 1,0 sec

GERMAN REGuLAtIONS

Specifications subject to alteration

Airports / railway stations

Please note:

For above-ground railway station areas a rated duration of 1 hour may be admissible, depending on the evacuation plan.

Exceptions:

none

Definition:

none

Airports / railway stations, VDE 0108, Part 100

EN 1838

Important note:

the above are model regulations only. Regional building code regulations may also apply in certain cases.

MODEL BuILDING CODE REGuLAtIONS VDE 0108, PARt 100 – EMERGENCY LIGHtING

See page 260 for symbol legend

Page 262: Emergency Lighting A1

260

GBS

BS

1h

DS

≤ 0,5 sec

3h

8h

≤ 1,0 sec

Zeitraum der Gefährdung

BS

≤ 15 sec

je nach Panikrisiko oder Gefährdungsbeurteilung

1 - 15 secEB

0,5 lx

NEA < 0,5 sec

1,0 lx

NEA < 0 sec

CPS

GDS

3,0 lx

NEA < 15 sec

LPS

En50%5 sec

60 sec100%

E = 0,1 x Enmindestens aber 15 lx

GERMAN REGuLAtIONS

Specifications subject to alteration

SYMBOL LEGEND VDE 0108, PARt 100

Switching time ≤ 0.5 sec

Switching time ≤ 1.0 sec

Switching time ≤ 15 sec

Switching time 1 - 15 sec (depending on panic risk or danger level)

Rated duration: 1 hour

Rated duration: 3 hours

Rated duration: 8 hours

Rated duration: (duration of danger)

Escape route sign, non-maintained

Escape route sign, maintained

Emergency escape luminaire, non-maintained

Switched non-maintained

Switched maintained

Central battery systems

Group battery systems

Single battery systems

Emergency power supply system < 0.5 sec

Emergency power supply system < 0 sec

Emergency power supply system < 15 sec

Nominal illuminance 0.5 lx

Nominal illuminance 1.0 lx

Nominal illuminance 3.0 lx

Nominal illuminance 50% Nominal illuminance 100%

> 10% of nominal illuminance min. E > 15 lx

Page 263: Emergency Lighting A1

261

GERMAN REGuLAtIONS

Specifications subject to alteration

Costs for weekly tests

LuminairesBattery/Batteries

Systems

During the planning phase, cost optimization proce-dures can be applied to

system purchases.

Luminaire installationSet-up

(CPS/LPS)

Purchase of easy to install luminaires

Mixed operation techno-logy obviates the need for

cabling

Power supplyMaintenanceSpare parts

State of the art LED techno-logy reduces energy costs

and battery capacities

use of lamps with a long service life reduces repair

and spare parts costs

Automatic testing systemsreduce labour costs

SAFETY LIGHTING COSTS

COST SAVINGS OPTIONS

Purchase costs

Purchase costs

Installation costs

Installation costs

Operating costs

Operating costs

Luminaires with a test button

Luminaires with an automatic self-test function

Luminaires with an automatic self-test function

and testing system (DALI, MWEBplus, MultiDigit®)

tasks Employee must test all luminaires once a week, which requires a lot of time. Ceiling mounted luminaires can be tested only using a ladder.

Employee must only control all luminaires once a week.

Employee receives testing results at a central workstation or via e-mail.

time required 7 minutes per luminaire 3 minutes per luminaire total of 5 minutes

Hourly labour costs 10.00 € 10.00 € 10.00 €

System with: 30 luminaires 30 luminaires 30 luminaires

time required for weekly function test

210 min. 90 min. 5 min.

Costs for weekly function test 35.00 € 15.00 € 0.83 €

Annual costs 1,820.00 € 780.00 € 43.33 €

Page 264: Emergency Lighting A1

262

ga

a

gb

a

GERMAN REGuLAtIONS

Specifications subject to alteration

Design of escape signs

square rectangular b = 2 x a

Contrast colour (white)Safety colour (green)

Luminance

Luminance during mains-power operation in accordance with DIN 4844-Part 1 (05/2005): average luminance of contrast colour: min. 500 cd/square meter

Escape route / Emergency exitDirectional arrow

Design of escape signs

Escape signs are always to be composed of a directional arrow and the escape route/ exit symbol.

Safety and health signs

1. Scope of application

these safety provisions apply to safety and health signs at work.

2. Definitions

Escape sign

means a safety sign indicating an escape route, emergency exit, first-aid station, or the route to such facilities.

3. Escape routes

Escape routes are clearly marked routes that allow (a) employees to evacuate a facility; and (b) rescue and evacuation of injured employees or employees exposed to hazards.

4. Visibility

- Safety signs must be installed in such a way that they are clearly visible and securely attached at all times. they must be made of materials that are resistant to the environmental factors.

- If a safety sign is installed at a location with inadequate natural light, the sign’s visibility is to be ensured via artificial lighting.

5. Maintenance

the employer is responsible for maintenance of workplace health and safety signs.

6. Testing

- the employer is to ensure that all health and safety signs are inspected at two years intervals at a minimum.

- the employer is to ensure that all technical elements (such as luminaires) are tested at least once a year by an experienced technician.

Directional arrow Escape route / Emergency exit

Emergency exit

DIN 4844, PARt 1 AND PARt 2 BGV A 8

Page 265: Emergency Lighting A1

263

GERMAN REGuLAtIONS

Specifications subject to alteration

Scope

this standard applies to, among others, the installation of electrical and safety systems in the following types of structures that are used for gatherings of people:

- Places of assembly

- Exhibition halls

- theatres and cinemas

- Sports stadiums

- Points of sale

- Restaurants

- Nursing homes

- Accomodation facilities

- Schools

- Car-parks

- underground car-parks

- Swimming pools

- Airports

- Railway stations

- Multi-storey buildings

- Workplaces

Power sources

DC circuits must be protected against overload by a 2-pole fuse

Connecting diagrams

A detailed connecting diagram for the electric system must be available near the main distribution board of the backup power supply and is to indicate the following:

- Safety circuits (including monitoring systems)

- type and number of loads per circuit

- Load of each single circuit

- total system load

Site plans and information concerning each single electric load as well as its location are also to be available. Such plans are to indicate the following:

- Exact position of all electrical operating locations

- Exact position of distributors, cables and routes (except for final circuits)

- All safety related electrical loads and circuit names

- Safety related control and monitoring units

Cross sections

Final circuits must have a cross section of min. 1.5 mm².

Displayed information for safety monitoring purposes

For reasons of safety, system operation is to be monitored and the following information is to be displayed:

- System ready for operation

- Battery mode

- System error

Test logs

the facility vendor is to provide the facility operator with log books where all test results are to be recorded and stored for a period of 4 years.

Electronic log books from a DIN EN 62034 conformant automatic testing system are also regarded as valid log books if the test results can be archived for a period of 4 years and displayed or printed out.

Electric circuits

Safety circuits must be physically isolated from other cable routes and may pass through fire risk areas – but not explosion risk areas - if they are fire resistant.

However, conducting safety circuits through fire risk areas should be avoided wherever possible.

Power sources

If only one backup power source is available it is not to be used for any other purpose.

Absence of feedback

Errors and failures in any safety system are not to affect the loads of any other system.

VDE 0100, PARt 718 – BuILDINGS FOR GAtHERINGS OF PEOPLE

VDE 0100, PARt 560 – SYStEMS WItH NOMINAL VOLtAGES OF uP tO 1 000 V

Page 266: Emergency Lighting A1

264

GERMAN REGuLAtIONS

Specifications subject to alteration

Regional German building codes

Landesbauordnung (MBO)

- (Model) School building directive 07/1998

- (Model) Places of assembly regulation 06/2005

- (Model) Points of sale regulation 09/1995

- (Model) Directive for multi-storey buildings 04/2008

- (Model) Car-parks regulation 07/1997

- (Model) Accomodation facilities regulation 12/2000

- (Model) Directive concerning temporary buildings 05/2007

- ...

Workplace health and safety regulations

Workplace regulation

Workplace directive

Trade and Industry Regulation

Regulations for the prevention of accidents (BGV A8, BGR 216, BGR 131 etc)

1. Scope

this directive applies to

- Wiring systems in the following locations: essential stairwells; landings and spaces that connect essential stairwells and exits; essential corridors, excluding open corridors in front of external walls,

- Passing cables through walls, ceilings and the like,

- Fire protection for electrical wiring systems.

2. Definitions

Wiring systems are composed of electric cables and/or conduits and the relevant fittings, connections, monitoring and control systems, power supplies, distributors and insulating material for cables, including the attachment hardware and coatings used for the wires/conduits.

Fiberoptic cables and electric cables are classified as electric wires.

3. Fire resistance

Fire-protected distributors for electrical wiring systems pursuant to section 5.3 of directive (M)LAR must:

- be located in suitable spaces that are not used for other purposes and that are separated from other rooms by walls, ceilings or doors that are adequately fire-protected and – apart from the doors – made of incombustible materials

- be kept in separate housings with a certified fire-resistance duration rating; or

- be enclosed in components (including the enclosures) that exhibit adequate fire resistance duration and that are composed of incombustible materials (excluding the enclosures); operability of the distributor’s electric components must be ensured in the event of fire for the entire fire resistance duration.

the fire resistance duration must be no less than 30 minutes for:

- Emergency escape lighting systems, to the exclusion of wiring systems that supply power to emergency escape lighting within only one fire compartment of one storey or within one stairwell; maximum floorspace per fire compartment: 1,600 square meters.

BuILDING CODE

WIRING SYStEMS DIRECtIVE ((M) LAR) (11/2005)

REQUIREMENT

Compliance with generally accepted standards is required

Building permit

Page 267: Emergency Lighting A1

265

GERMAN REGuLAtIONS

Specifications subject to alteration

New „Technical rules for workplaces“

ASR A1.3 Safety and health signs (04/2007)

ASR A2.3 Escape routes, emergency exits, escape and rescue plan (08/2007)

ASR A3.4/3 Emergency escape lighting, optical safety guidance systems (05/2009)

the regulation titled BGR 216: Optische Sicherheitsleitsysteme (einschließlich Sicherheitsbeleuchtung) (optical safety guidance systems (including safety lighting)), will remain in force until 31 August, 2010, along with the regulation titled ASR A3.4/3. In May 2009, the old workplace directive titled ASR 7/4: Sicherheitsbeleuchtung (emergency escape lighting) was superseded by the regulation titled ASR A3.4/3.

ASR A1.3

Contents

1. Objectives

2. Scope

3. Definitions

4. General

5. Signs

6. Escape and rescue plans

7. Labelling of containers and conduits containing dangerous substances Annex(es)

Objectives

this directive ASR A1.3 lays down the requirements for safety and health signs at workplaces. Pursuant to article 3 of the workplace regulation titled Arbeitsstättenverordnung and section 1.3 of the appendix thereof, safety and health signs are to be used in order to avert workplace safety and health risks.

Scope

the workplace regulation Arbeitsstättenverordnung implements Eu Directive 92/58/EEC on the minimum requirements for the provision of safety and/or health signs at work.

Escape and rescue route plan

Directional arrow Escape route / Emergency exit

WORKPLACE DIRECtIVES

Page 268: Emergency Lighting A1

266

GERMAN REGuLAtIONS

Specifications subject to alteration

ASR 2.3 Escape routes, emergency exits, escape and rescue plan

Contents

1. Objectives

2. Scope

3. Definitions

4. General

5. Design, dimensions

6. Application

7. Signs

8. Emergency escape lighting

9. Escape and rescue plan

Objectives

this workplace directive lays down the requirements (pursuant to article 4, paragraph 4, and item 2.3 of the appendix to the workplace regulation titled Arbeitsstättenverordnung) concerning (a) the installation and maintenance of escape routes and emergency exits; and (b) escape and rescue plans, with a view to ensuring safe workplace evacuation in the event of danger.

Scope

this workplace directive applies to the installation and maintenance of escape routes and emergency exits in buildings and similar structures to which employees have access during work, as well as to the elaboration of escape and rescue plans and related exercises. Such routes and plans are to be elaborated in a manner that allows for the possibility that outside parties may be present during an emergency.

This workplace rule does not apply

- to installation and maintenance of the following:

a) outdoor workplaces that are not enclosed on all sides

b) building construction sites

c) areas in any structures that are occupied solely for maintenance and inspection purposes

d) areas in any structure where handicapped people are employed

- to leaving work equipment behind in the event of danger within the meaning of article 2, paragraph 1, of the Industrial Safety and health regulation (Betriebssicherheitsverordnung).

In comparable situations, this directive may be applied to any excluded areas. If not, specific measures have to be taken to ensure employee safety in the event of danger.

Signs

Escape routes, emergency exit and door signs are to conform with the directive titled ASR A1.3.

Emergency escape lighting

Section 8 of the directive titled ASR A2.3 (concerning escape routes, emergency exits, escape and rescue plans) defines the conditions under which emergency escape lighting is required for escape routes.

In the scenarios described in the said section 8, the primary and possibly also the secondary escape route are to be equipped with emergency escape lighting.

Escape routes are to be equipped with emergency escape lighting insofar as safe evacuation of the workplace in the event of a general lighting failure cannot be guaranteed.

Emergency escape lighting may be required for example in workplaces that exhibit the following characteristics (among others):

- Workplaces with a large number of employees or that are located in tall buildings; workplaces with high risk areas or unclear escape routes

- Workplaces used by persons who are unfamiliar with the place

- Workplaces where large spaces such as open-plan offices or retail spaces must be traversed during an evacuation

- Workplaces with no natural light, such as basement rooms.

Escape and rescue plan

the employer is to devise a suitable escape and rescue plan for those areas of the workplace whose location, dimensions and/or type necessitate the use of such a plan.

Escape and rescue plans must be up to date, easy to understand and read, and must be elaborated using standard safety colours and symbols.

For requirements concerning escape and rescue plans, see the regulation titled ASR A1.3.

Escape and rescue plans are to incorporate graphic elements indicating the following:

- Site plan or parts thereof

- Escape and rescue routes

- First-aid posts

- Fire fighting equipment

- Assembly point location

- Point of location of the user (“you are here” indication)

the escape and rescue plans is to be displayed in sufficient number in suitable areas of the workplace.

WORKPLACE DIRECtIVES

Page 269: Emergency Lighting A1

267

GERMAN REGuLAtIONS

Specifications subject to alteration

ASR 2.3 Escape routes, emergency exits, escape and rescue plan

Section 8 of the directive titled ASR A2.3 defines the conditions under which emergency escape lighting is required for escape routes.

In the scenarios described in this section of the directive, the primary and possibly also the secondary escape route are to be equipped with emergency escape lighting.

ASR A3.4/3 Emergency escape lighting, optical safety guidance systems

Contents

1. Objectives

2. Scope

3. Definitions

4. Emergency escape lighting

5. Optical safety guidance systems

6. Operation, maintenance and testing

7. Supplementary requirements for building sites

Objectives

this workplace directive specifies the requirements concerning the installation and maintenance of emergency escape lighting and optical safety guidance systems pursuant to article 3, paragraph 1, and article 4, paragraphs 3 and 4, and notably item 2.3 paragraph 1 and item 3.4 paragraph 3 of the appendix to the workplace regulation titled Arbeitsstättenverordnung.

Scope

this workplace directive (a) applies to the installation and maintenance of emergency escape lighting and optical safety guidance systems in workplaces; (b) cites examples of types of workplaces which may require emergency escape lighting or optical safety guidance systems: and (c) lays down technical specifications for emergency escape lighting and optical safety guidance systems and the use thereof.

Emergency escape lighting

4.1 Escape route lighting

Section 8 of the directive titled ASR A2.3 defines the conditions under which emergency escape lighting is required for escape routes.

In the scenarios described in this section of the directive, the primary and possibly also the secondary escape route are to be equipped with emergency escape lighting.

4.2 High risk task area lighting

In workplaces where accidents are likely to occur in the event of a general lighting failure, the required illuminace of the emergency escape lighting is to be reached within 0.5 seconds and must continue at least for the duration of the risk.

Escape routes are to be equipped with emergency escape lighting insofar as safe evacuation of the workplace in the event of a general lighting failure cannot be guaranteed.

(ASR A2.3 Paragraph. 8).

Workplaces where employee health and safety are at risk in the event of a general lighting failure and where emergency escape lighting is required include the following among others:

High-risk workplaces:

- Laboratories

- Rooms that are darkened for operation

- Rooms that accommodate electrical equipment or technical building systems

- Workplaces with a large number of employees

- Workplaces that are located in tall buildings

- Workplaces with high-risk areas

- Workplaces with unclear escape routes

- Rooms or areas used by persons who are unfamiliar with the place

- Workplaces where large spaces such as open-plan offices must be traversed during an evacuation

- Rooms with no natural light

- Working areas where long trailing equipment or machines are used

- Areas containing control units for systems that are subject to continuous monitoring (e.g. control rooms)

- Workplaces with immersion baths containing heated liquids, casting pits or acid baths

- Building construction sites

Directive ASR A3.4/3 applies in many cases to building construction sites because of the high risk for persons.

Emergency escape lighting is essential in cases where there is not sufficient natural light to light escape routes so as to allow for safe workplace evacuation.

Building construction sites used after dark

the illuminance of emergency escape lighting for escape routes must be at least 1 lux, with a uniformity of less than 40:1.

Escape route illumination

Identification of escape routes via the relevant signs

WORKPLACE DIRECtIVES

Page 270: Emergency Lighting A1

268 Specifications subject to alteration

ESCAPE LIGHtING PLANNING

Power supply cable

max. 20 luminaires or 815 VAmax. 20 luminaires or 815 VAmax. 20 luminaires or 815 VAmax. 20 luminaires or 815 VA

PLANNING

Important issues:

1. Is safety lighting required? Building permit, building codes and regulations, work safety laws, workplace regulations, etc.

2. Wich type of self-contained or central battery system (CPS / LPS) is to be used?

See VDE 0108, Part 100, table A1 (see table on page 246)

3. Which is the required nominal operating time?

See VDE 0108, Part 100, table A1 (see table on page 246)

4. Escape and rescue routes plan the escape and rescue route plan indicates all mandatory escape routes and emergency exits (in the absence of such a plan, escape routes and emergency exits are to be indicated by the plannner or architect).

5. LuminairesSee EN 1838 for detailed information concerning the installation of safety signs. the number of emergency escape luminaires is to be determined using the spacing table (Leuchtenabstandstabelle) or a lighting calculation formula.

The above ALSO applies to the planning process for a single-battery system!

Potencia y circuitos

6. Capacity of all luminaires = total capacity the battery aging factor must be factored in. We recommend that a 25% aging factor be applied.

7. Total capacity, including the aging factor (loss in capacity) = battery capacity

See table on page 125, where ventilation cross sections are indicated as well.

8. Number of fire compartmentsConsult your planner or architect.Fire compartment dimensions in accordance with directive MLAR (exceptions are allowed in some regions).

9. Number of circuits per fire compartment=> mixed operation => 2 circuits per fire compartment at a minimum => standard operation => 4 circuits per fire compartment at a minimum Important note: Maximum no. of luminaires per circuit: 20, Maximum circuit load: 815 VA !

10. Number of circuits divided by 4 = number of circuit modules

11. Sub-stationsFor calculating the number of circuits and modules per sub-station, the same calculation system that is used for central battery systems circuits calculation is to be applied.

Page 271: Emergency Lighting A1

269Specifications subject to alteration

ESCAPE LIGHtING PLANNING

PLANNING

Fire compartment 1 max. 1,600 square meters

Fire compartment 1 max. 1,600 square meters

Fire compartment 2 max. 1,600 square meters

Fire compartment 2 max. 1,600 square meters

E 30 Junction box

E 30

EIB BuS

F 90

E 30 Junction box

NYM to distributor in accordance with LAR

E 30 Power supply cable E 30

fused junction box

Fire compartment 3 max. 1,600 square meters

Fire compartment 3 max. 1,600 square meters

E 30

EIB BuS

F 90

For sub-stations planning, please note:

Active star network

Please note that for this type of network an output in the CPU must be provided for each sub-station.

Linear network

Please note that for this type of network E30 junction boxes are to be provided for each fire compartment.

E 30 junction box

Installation example

Page 272: Emergency Lighting A1

270

Exhibition stand emergency lighting light+building 2010

Page 273: Emergency Lighting A1

271

Appendix

Service 272 - 273

EVG symbol 274

LED symbol 275

Catalogue number codes 276

Motifs and lettering for emergency luminaires 277

Motifs and lettering for luminaire signs 278 - 279

Lamps 280

Terms of conditions of sale and delivery 281

Catalogue number index 282 - 286

Alphabetical index 287 - 288

Technical support 289

After Sales Service 289

Contact for emergency lighting 289

Page 274: Emergency Lighting A1

272

SErViCE

Specifications subject to alteration

Abbreviations

L Lengh

B Width

H Height

D Diameter

LP Pendant length

AL Extension

DA recess opening (width x length or Ø)

HE Luminaire installation height

Luminaire with Edison lampholder

EVG electronic ballast

BS non-maintained

DS maintained

GDS switched maintained

TLS staircase light circuit

LPS Low Power Supply

CPS Central Power Supply

NEA Emergency power supply system

EPS Emergency power supply system

SK Electric circuit

IOM in/Out module

Protection classes

Protection class I

Luminaires for connection to a protective conductor provided on site. The protective conductor terminal is marked . in case of malfunction: Protection through power supply switch-off by overcurrent protection device.

Protection class II

Base insulation protects against direct contact. in case of mal-function: Additional or reinforced insulation protects against indirect contact.Many protection class i luminaires are also available with pro-tection class ii on request.

Protection class III

Luminaires for connection to safety extra-low voltage (SELV, max. 50 V AC), e.g. using safety transformers or other sources of voltage with comparable safety features. in case of malfunction: Protection through effectively harmless volt-age. Mains connection via luminaire equipment with dual or reinforced insulation on the mains side.

The information relating to the resistance of our luminaires to solid objects and water is based on EN 60598/VDE 0711.

Specifications subject to alteration.

Types of protection according to EN 60598/VDE 0711

1st digit: Protection against solid objects

iP 2X Protection against penetration of solid objects

> 12.5 mm

iP 3X Protection against penetration of solid objects

> 2.5 mm

iP 4X Protection against penetration of solid objects

> 1 mm

iP 5X Protection against dust penetration

iP 6X Dust-proof

2nd digit: Protection against water

iP X1 Luminaires are protected against water drops

(vertically falling drops of water)

iP X2 Luminaires are protected against water drops

(drops of water up to 15° from the vertical)

iP X3 Luminaires are protected against rain

iP X4 Luminaires are protected against water sprays

iP X5 Luminaires are protected against water jets

iP X6 Luminaires are protected against rough sea or

heavy jets of water

iP X7 Protection against temporary immersion

iP X8 Protection against continuous immersion

The type of protection indicated for surface mounted, recessed,

pole or pendant luminaires only applies for the defined and/or

permitted type of luminaire installation.

_ _ m

Electric circuit identification labels | VDE 0108/DIN 56932A sheet of circuit identification labels in accordance with DiN 56932; self-adhesive white plastic foils with red silk screen printing for application on plain surfaces. One sheet contains 12 circuit identification labels; circuit numbers 001 to 150 are available from stock. Please indicate circuit numbers when placing your order, e.g. 99350/017!

Article number99350

Electric circuit identification labels | VDE 0108/DIN 56932Light plastic plate for application on roughcast or any other irregular surfaces to be used as support for circuit identification labels 99350.

Article number99351

Circuit identification labels, blank A sheet of circuit identification labels in accordance with DiN 56932; self-adhesive white plastic foils with red silk screen printing for application on plain surfaces. One sheet contains 12 circuit identification labels for application of personalized lettering;

Article number99350.1

Page 275: Emergency Lighting A1

273

SErViCE

Specifications subject to alteration

Ballast

Our luminaires are mainly fitted with low-loss ballast. They are designed for 230 V/50 Hz (equipment with other specifications is available on request).

Luminaires with electronic ballast are indicated by the code at the end of the catalogue number, e.g. .79 or have their own separate order number with explanatory text.

Electrotechnical variants and additionsCodes are marked by a two-digit suffix separated by a point at the end of

the catalogue number.

Code .03

Version with automatic self-test function and feedback to PZ 50

Code .04

Version with automatic self-test function and feedback to MultiDigit® and MWEBplus

DALI Code .07

Version with automatic self-test function and feedback to DALi unit

EVG Code .79

Versions with electronic ballast

Control 1 Code .71

Monitoring module for GV 1500 and rZBbasic

TWIN-Control Code .72

Monitoring module for mixed operation via switch for GV 1500 and rZBeasy 202. 3 different switching types can be switched and operated contemporaneously in one circuit.

SINGLE-Control Code .81

Monitoring module for LUXiFAir and LUXiFAirlight

DUO-Control Code .82

Monitoring module for mixed operation via switch for LUXiFAir and LUXiFAirlight

General information

Use of emergency lighting modules

The distances between EB and emergency lighting module must be observed

as longer cable lengths might impair the function.

We recommend:

Distance EB <-> Emergency lighting module: 0.5 m

Distance LLB <-> Emergency lighting module: 2.0 m

Electrotechnical safetyWe guarantee that we have manufactured and tested all of the luminaires in this catalogue carefully in accordance with international standard EN 60598 (VDE 0711).Special luminaires are manufactured in accordance with this standard.

Safety marks

The ENEC mark is a European test and certification mark for luminaires and electrical luminaire components.

Luminaires bearing this mark can be mounted directly onto normally inflammable surfaces (in accordance with EN 60598-1).

Luminaires bearing this mark have a limited surface temperature and are suitable for premises where dust or fibres can create a fire risk.

Luminaires bearing this mark are suitable for mounting on or in furniture made of materials with unknown properties; this applies, in particular to flammability.

Luminaires marked with the “ball impact protection” symbol are suitable for use in sports facilities. They are manufactured in accordance with the test conditions defined in VDE 0710.

Luminaires marked “ta 15°C” are designed for ambient temperatures of 15°C and are also suitable for use outdoors.

The CE mark is not a safety mark. it indicates that the product complies with European Union directives.

Symbol explanations

Luminaires for escape route identification

Luminaires for escape route illumination

Sign for luminaires with Edison lampholder

ta

Page 276: Emergency Lighting A1

274

SErViCE

Specifications subject to alteration

LuminAirES for fLuorEScEnt LAmPS with

ELECTrONIC BALLAST

EBs enhance the lighting quality

Quick, silent and flicker-free start

Constant, steady light

No flickering electrodes

No stroboscope effects

Dimmable (dimmable EB)

Controllability, option for integration into control systems

Automatic shutoff of defective lamps (no flickering)

Automatic restart following lamp change

EBs save energy and costs

Low loss performance by EBs

Low system power intake

High system light yield

Longer (30-50%) service life of lamps

Longer lamp replacement intervals

Elimination of starters and capacitors

Low heat generation

Gentle warm start and high switching capacity of lamps

Suitable as emergency lighting

The „lamp plus EB“ system has a considerably reduced power intake and generates significantly less heat. EBs themselves generate little heat, thus reducing climate control measures – resulting in reduced operating costs for the air conditioning system.

The service life of EB-operated lamps increases by 30-50 percent as a result of the reduced load on the lamp and electrodes. A three-band fluorescent lamp burns for 8,000 hours on an LLB compared to 14,500 operating hours on an EB.

in addition to limiting the current, EBs also perform the task of starting and act as compensation condensers. Defective lamps are switched off auto-matically and do not flicker. Lamps are re-started automatically following replacement.

EBs start the lamps quickly, silently and without any flickering.

A warm start (pre-heated electrodes) protects the lamp and prolongs its serv-ice life. EBs developed specially for three-band, 16 mm diameter fluorescent lamps are equipped with cut-off technology that switches the coil heater off if permitted by the lamp operation. This increases the service life of the lamp by another 20 percent.

in HF operation, the lamp voltage is smoother. Lamps operated on EBs therefore produce constant and steady light, with no flickering electrodes or stroboscope effects generated by moving parts.

EBs are largely immune to voltage and frequency fluctuations. in addition, since most of them run on direct current, they can be switched to battery operation in the event of a power failure and used as emergency lights.

if the EB malfunctions, it automatically disconnects itself from the mains.

ENErGY EFFICIENCY

energy savings (25-30%)longer lamp life (approx. +50%)

ENVIrONMENT

reduced energy consumption (25-30%)

longer lamp life (approx. 50%)less lamp waste (approx. 30%)

SYSTEM

Most EB luminaires are suitable for direct current operation. They

can be connected to the emergency lighting’s group and

central battery systems.

Page 277: Emergency Lighting A1

275

SErViCE

Specifications subject to alteration

LED stands for light emitting diode, an electronic semi-conductor component.

LEDs supply constant full-beam immediate light. Unlike incandescent lamps, LEDs do not radiate temperature. They emit light in a narrow spectral range and do not emit any infrared or ultraviolet radiation.

LEDs have a high switching speed.

The luminous flux is determined by the electrical current. As such, we rec-ommend the use of a constant source of current. At the current state of development, the service life exceeds 50,000 hours and is dependent on various factors.

Thanks to LED technology, the luminaire industry can design virtually main-tenance-free luminaires.

in summary, it is safe to say that LEDs will supersede incandescent lamps: Compared with conventional lamps, they consume less energy, generate less heat, are insensitive to shock, have considerably shorter switching times and a long service life.

LuminAirES with

LiGht EmittinG DiodES

ENErGY EFFICIENCY

low power intake

long service life ≥ 50,000 hours

FUTUrE

LEDs are the lamps of the futu-re. Thanks to the numerous

benefits, LED development is progressing at a phenomenal

speed.

rZB offers luminaires fitted with LED lamps for selected areas of

application.

These products can be identified by the symbol:

Page 278: Emergency Lighting A1

276 Specifications subject to alteration

EMErGENCy LiGHTiNG | ArTiCLE NUMBEr CODiNG

replace the X of the catalogue number with the desired colour.Example:Article number Article number with with X indication of colour671501.00X 671501.004

within the table• luminaire available with this module– luminaire not available with this module

Please add to the catalogue no., includ-ing the colour code, the code for any optional article (separated by a dot)

.03 for PZ 50

.04 for MultiDigit®

.07 for DALi

Article number Article number with with indication indication of colour of colour + y and indication of optional article671501.004.Y 671501.004.03

H

L B

H

L B

H

LLA

BBA

HE

5-35

3

180

151233

4523Ø4,5

15

15

150

233Ø5

12,5

50

1640

4255

255270

HA

LHE

1-30

H

LA

BL

HA

HE

LA

B

H

132150

210220

130150

200220

Article number Type of installation

Viewing distance

Luminous flux factor

Lamp/Wattage PZ 50 (.03)

MultiDigit (.04)

DALi (.07)

rated operat-ing time

Dimensions

671501.00X.y Wall (surface) 14 m - 4 x LED 1 W • • - 3 h L 233, B 40, H 180

671502.00X.y Ceiling (surface) 14 m - 4 x LED 1 W • • - 3 h L 233, B 40, H 184

671518.00X.y Ceiling (recessed) 14 m - 4 x LED 1 W • • - 3 hL 270, B 55, H 100 LA 255 x BA 42, HE 90

671546.12X.y Wall (recessed) (cavity wall) 14 m - 1 x LED 4 W • • - 3 h

L 220, B 2, H 150 LA 210 x BA 132, HE 90

671546.00X.y Wall (recessed) (solid wall) 14 m - 1 x LED 4 W • • - 3 h

L 220, B 2, H 150 LA 200 x BA 130, HE 80

Wall (surface) Ceiling (surface) Ceiling (recessed) Wall (recessed) (cavity wall) Wall (recessed) (solid wall)

Series: LED Halyxx®

Type of protection: IP 40 Protection class: i Viewing distance: 14 m Ceiling thickness: 5-35 mm Wall thickness: 1-30 mm

For escape route identification

Base: aluminium extrusion profile; display panel: highly transparent panel with motifs on one side/both sides.

LED included.

Please specify legend number when ordering!

Operating mode: Can either be connected in non-maintained power mode (BS) or in maintained power mode (DS).

Ballast mains/emergency: EB

Available colours (X): 2 = white (only wall installation) 4 = aluminium, anodised (all variants)

H

L B

H

L B

H

LLA

BBA

HE

5-35

3

180

151233

4523Ø4,5

15

15

150233

Ø5

12,550

1640

4255

255270

HA

LHE

1-30

H

LA

BL

HA

HE

LA

B

H

132150

210220

130150

200220

14 m

Page 279: Emergency Lighting A1

277Specifications subject to alteration

Motifs for escape route identification –worKPLAcE LEGiSLAtion

Legends in accordance with UVV BGV A8 and EECr 92/58

Background colour: green

1000 Escape route to the right

1117 Escape route to the upper right

1118 Escape route to the lower right

1001 Escape route to the left

1119 Escape route to the upper left

1120 Escape route to the lower left

1002 Emergency exit, arrow pointing down

1051 Meeting point

1166 Emergency exit, arrow pointing down

1003 Escape route to the right

1113 Escape route to the upper right

1114 Escape route to the lower right

1004 Escape route to the left

1115 Escape route to the upper left

1116 Escape route to the lower left

1005 Emergency exit, arrow pointing down

Motifs for escape route identification –BuiLdinG And worKPLAcE LEGiSLAtion

Legends in accordance with DiN 4844, UVV BGV A8 and EECr 92/58

Background colour: green

2003 Escape route to the right

2113 Escape route to the upper right

2114 Escape route to the lower right

2004 Escape route to the left

2115 Escape route to the upper left

2116 Escape route to the lower left

2005 Emergency exit, arrow pointing down

2006 Emergency exit, arrow pointing up

1051 Meeting point

Please quote the motif numbers when ordering safety luminaires with legends.The size of the legend will be matched to the luminaire that you order.

Luminaires with enclosed escape route motifs are supplied in accordance with DIN 4844, UVV BGV A8 and EECr 92/58 (approved by building and workplace legislation). Please indicate the appropriate symbol numbers if you require delivery of other legends.

The aspect ratios of the symbols for escape route identification comply with DiN 4844 and UVV BGV A8, i.e. square-shaped symbols have an aspect ratio of 1:1 and rectangular symbols of 2:1. in the case of luminaires with different dimensions, the remaining illuminated surfaces will be filled with opal.

EMErGENCy LiGHTiNG | MOTiFS AND LETTEriNG

Page 280: Emergency Lighting A1

278 Specifications subject to alteration

LUMiNAirE SiGNS | MOTiFS AND LETTEriNGS

Notes for ordering legends and inscriptions

Please always indicate the motif number or text when ordering luminaire signs with legends or inscriptions. The size of the legend or inscription will be matched to the luminaire that you order.

Motifs

Please indicate motif number, e.g. 1019

Motif combinationsindicate the motif numbers from left to right, separated by a forward slash, e.g. 1019/1013

Letteringirrespective of their syntax, letterings are set in upper case, font: Helvetica regular, e.g. EXIT.

Please clearly order lower case if required, e.g. Lower case: Exit

Other standard fonts: Helvetica Medium and Helvetica Bold. Other fonts are available at extra cost. e.g. Helvetica Medium: Exit, Helvetica Bold: Exit

Lettering comprising several linesPlease specify the number of lines,e.g. two lines: CONGrESS CENTEr

Negative imaging of motifs and letteringQuote the motif number (text or digits) and specify “inverse”, e.g. 1019/inverse

Single coloured motifsAll motifs and lettering are mounted on a standard blue background. Other standard colours available at no extra cost: light blue, green, yellow, orange, red, grey Cover colours: silver, blackBackground colour: white/opalQuote the motif number (text or digits) and required colour(s), e.g. 1019/light blue / 1019/light blue/inverse

Numbersinclude the catalogue number 0001-0999e.g. 0692 / 0003

Motifs for numbers

Background colour: blue (standard)

0001-0999 Numbers

Motifs for direction indicators

Background colour: blue (standard)

1013 Arrow pointing right

1014 Arrow pointing left

1015 Arrow pointing down

1016 Arrow pointing up

1175 Arrow pointing left and up

1176 Arrow pointing left and down

1177 Arrow pointing right and up

1178 Arrow pointing right and down

1163 Angled arrow pointing left and up

1164 Angled arrow pointing right and up

Motifs for general signs

Background colour: blue (standard)

1017 Men‘s toilet

1018 Ladies‘ toilet

1019 Men‘s and Ladies‘ toilet

1021 Disabled toilet

1072 restaurant

1073 Cafeteria

1085 Hotel

1030 Cloakroom

1037 Stairway, up

1038 Stairway, down

1074 Lift

1033 Telephone

Motif No. Description

Special colours and fontsMulticoloured motifs or lettering, customised motifs and special colours or motif/text/number combinations are available at extra cost.

Please do not hesitate to forward your request to our sales team. Provide them with details or even a drawing of the sign. We require a template in either .TiFF or .EPS format (or a hand drawing) in order to manufacture custom motifs.

EXit

Exit

EXIT

EXIT

conGrESScEntEr

692

3

Page 281: Emergency Lighting A1

279Specifications subject to alteration

LUMiNAirE SiGNS | MOTiFS AND LETTEriNGS

1026 information

1086 Arrivals

1087 Departures

1088 Baggage drop

1089 Baggage collection

1090 Luggage lockers

1091 Taxi

1184 railway station

1185 Tickets / reservations

1186 Exchange/Bank/Cash dispenser

1187 Customs / Baggage control

1092 Car park

1024 Meeting point

1032 No smoking area

Other motifs or customised designs are available on request. There may be an additional cost.

Motifs for sport facilities

Background colour: blue (standard)

1075 Football

1093 Handball

1094 Volleyball

1095 Bowling

1079 ice hockey

1078 Golf course

1077 Swimming

1076 Gymnastics

1080 Athletics

1096 Ballet

1097 riding

The aspect ratios of the symbols (fire protection and first aid, etc.) comply with the regulations specified in the European Directive (92/58/EEC) „Minimum requirements for the provision of safety and/or health signs at work“, i.e. square-shaped symbols 1:1 and rectangular symbols 2:1. in the case of luminaires with different dimensions, the left and right borders are filled in opal.

Motifs for fire protection facilities

Legends in accordance with DiN 4844 and EECr 92/58Background colour: red

1057 Fire hose

1059 Fire extinguisher

1060 Fire alarm

1061 Direction indicator, right 1062 Direction indicator, left

1063 Direction indicator, straight ahead

Direction indicators only in combination with a symbol for a fire protection facility. Other motifs or custom-ised designs are available on request. There may be an additional cost.

Motifs for first aid facilities

Legends in accordance with DiN 4844 and EECr 92/58Background colour: green

1034 First aid station

1052 Stretcher

1053 Doctor

1054 Emergency telephone

1055 Eye-rinsing facility

1084 Emergency shower

1009 Direction indicator, right 1010 Direction indicator, left

1056 Direction indicator, straight ahead

Direction indicators only in combination with a sym-bol for a first aid facility. Other motifs or customised designs are available on request. There may be an additional cost.

Motifs for prohibition signs

Legends in accordance with DiN 4844 and EECr 92/58 Background colour: white; Symbol: black; Prohibition colour: red

1064 Smoking prohibited

1065 Fire, open flames and smoking prohibited

1179 restricted entry

Other motifs or customised designs are available on request. There may be an additional cost.

Motifs for mandatory signs

Legends in accordance with DiN 4844 and EECr 92/58

Background colour: light blue

1067 Eye protection mandatory

1068 Helmet mandatory

1069 Ear protection mandatory

1070 Protective gloves mandatory

Other motifs or customised designs are available on request. There may be an additional cost.

Legends in accordance with EECr 92/58, and/or DiN

40008 and DiN 25430. Background colour: yellow;

Symbol: black

1162 radioactive materials, ionising radiation

1172 Laser beams

1173 Explosive gases

Other motifs or customised designs are available on request. There may be an additional cost.

Motif No. Description Motif No. Description Motif No. Description

Any escape sign luminaire for central emergency power supply can also be ordered as luminaire sign. Plese see the section on luminiare signs of our current product selection guide.

Page 282: Emergency Lighting A1

280 Specifications subject to alteration

LAMPS

Design- ZVEi- iLCOS- Nominal Nominal Max. luminous Beam Base nation/ abbre- abbre- wattage luminous flux intensitiy angle Symbol viation viation [W] Φ [lm] l [cd] [°]

Design- ZVEi- iLCOS- Nominal Nominal Max. luminous Beam Base nation/ abbre- abbre- wattage luminous flux intensitiy angle Symbol viation viation [W] Φ [lm] l [cd] [°]

Incandescent lamp

A60 iAA 15 90 E27

25 220 E27

40 415 E27

60 710 E27

75 935 E27

A

The specifications for the lamps used in the rZB catalogue are listed as neutrally as possible below. The lamp abbreviations are indicated in iLCOS and ZVEi LBS.The photometric values and bases for the lamps must be compared with the actual manufacturer’s specifications prior to incorporation in any light calculations or plan-ning. The table lists the maximum values (luminous flux Φ and luminous intensity i) for many of the lamps. in the case of lamps for which just one manufacturer is known at present, the manufacturer is indicated as a footnote.Manufacturer codes: 1) Philips 2) Sylvania 3) Osram 4) GE 5) rZB 6) Venture Lighting 7) Narva 8) Megaman

Compact fluorescent lamp, single tube

TC FSD 5 250 G23

7 400 G23

9 600 G23

11 900 G23

TC-EL FSD 5 250 2G7

7 400 2G7

9 600 2G7

11 900 2G7

TC

Compact fluorescent lamp, quadruple tube

TC-QEL FSMH 4)57 4300 GX24q-5

4)70 5200 GX24q-6

TC-QEL

Compact fluorescent lamp, triple tube

TC-T FSM 13 900 GX24 d-1

18 1200 GX24 d-2

26 1800 GX24 d-3

TC-TEL FSMH 13 900 GX24 q-1

18 1200 GX24 q-2

26 1800 GX24 q-3

32 2400 GX24 q-3

42 3200 GX24 q-4

57 4300 GX24 q-5

70 5200 GX24 q-6

TC-TEL FSMH 1)60 4000 2G8

1)85 6000 2G8

1)120 9000 2G8

TC-T

TC-TEL

Compact fluorescent lamp, double tube

TC-D FSQ 10 600 G24 d-1

13 900 G24 d-1

18 1200 G24 d-2

26 1800 G24 d-3

TC-DEL FSQH 10 600 G24 q-1

13 900 G24 q-1

18 1200 G24 q-2

26 1800 G24 q-3

TC-D

Fluorescent lamp

T7 FD-Ø7 6 330 W4.3

8 540 W4.3

11 750 W4.3

13 930 W4.3

T16 FD-Ø16 4 140 G5

6 270 G5

8 450 G5

13 1 000 G5

FDH-Ø16 14 1 200 G5

21 1 900 G5

24 1 750 G5

28 2 600 G5

35 3 300 G5

39 3 100 G5

49 4 300 G5

54 4 450 G5

80 6 150 G5

T26 FD-Ø26 10 650 G13

15 950 G13

16 1 250 G13

18 1 350 G13

30 2 400 G13

T26-1m FD-Ø26-1m 36 3 100 G13

FD-Ø26 36 3 350 G13

38 3 300 G13

58 5 200 G13

T16/T26

Compact fluorescent lamp, square curved

TC-DD FSS 16 1 050 Gr8 2p

16 1 050 Gr10q 4p

4)21 1 375 Gr10q 4p

28 2 050 Gr8 2p

28 2 050 Gr10q 4p

38 2 700 Gr10q 4p

4)55 3 900 Gr10q-3 4p

TC-DD

Compact fluorescent lamp, flat

TC-F FSS 18 1 100 2G10

24 1 700 2G10

36 2 800 2G10TC-F

Compact fluorescent lamp, Mikro-Lynx

TC-FSE FBC 2)6 220 GX53

8)7 220 GX53

8)9 360 GX53

8)13 520 GX53TC-FSE

Compact fluorescent lamp, long

TC-L FSD 18 1 200 2G11

24 1 800 2G11

36 2 900 2G11

40 3 500 2G11

55 4 800 2G11

80 6 000 2G11

28 2 800 2GX11

TC-L

T16-r

Fluorescent lamp, ring-shaped

T16-r FC-Ø16 22 1 800 2GX13

40 3 200 2GX13

55 4 200 2GX13

1)60 5 000 2GX13

T32-r

Fluorescent lamp, ring-shaped

T29-r FC-Ø29 22 1 250 G10q

T32-r FC-Ø52 32 2 100 G10q

40 2 800 G10q

Page 283: Emergency Lighting A1

281Specifications subject to alteration

CONDiTiONS OF SALE AND DELiVEry

General: Unless explicitly agreed otherwise in writing, the following terms and conditions of sale apply, based on the „General Terms and Conditions of Supply“ for products and services supplied by the electrical industry. Special terms and conditions relate, above all, to export sales, which are based on the respective export terms as commonly applied. Our terms and conditions of delivery apply even if purchasers exclude the validity of the supplier’s terms and conditions of sale in their terms and conditions of purchase and we do not explicitly refute these. Verbal and/or special agreements are only binding if confirmed in writing by ourselves.

Prices: The prices indicated in the price list are gross per unit ex factory, excluding value added tax, and are non-binding. The applicable prices on the day the order is received are used as the basis for calculation unless the order in question has, exceptionally, been explicitly confirmed at fixed prices. Value added tax will be charged separately at the applicable rate.

Packaging: Packaging is charged at cost price. 2/3 of the calculated value of reusable packaging will be credited in the event of carriage paid returns. The same applies to container rent in the case of container shipment.

Delivery: Prices are gross ex factory, excluding packaging, which will be invoiced at cost price. Orders for immediate delivery with a value of more than Euro 500 will be shipped carriage paid to the recipient’s railway sta-tion in Germany, excluding packaging; orders valued at EUr 1,000 net or more will be shipped carriage paid to the recipient’s railway station in Germany including packaging. Deliveries are shipped on the basis of freight collect; freight costs will be deducted from the invoice. if the value of an order entitles the purchaser to carriage paid shipment or carriage paid shipment including packaging, we reserve the right to ship parts of the order at a later date ex factory and excluding packaging if production-related issues prevent us from delivering these items immediately.

Delivery times: Delivery times indicated in the order confirmations are largely adhered to; they are, however, not binding. We reserve the right to ship orders in parts. Any claims asserted on the grounds of delayed deliveries will not be admitted.

Transfer of risk: The risk is transferred to the purchaser as soon as the shipment leaves our factory. The recipient bears the risk of transportation. Goods damaged in transit will not be reimbursed if breakage insurance of 1% of the net invoice amount is refused.

retention of title: Shipped goods remain our property until all outstand-ing claims against the purchaser have been met in full. The purchaser may use the goods that are subject to retention of title in the course of normal business operations. The purchaser is not permitted to pledge or transfer the goods by way of security or to assign them by any other means; we must be notified immediately of any seizures by third parties or other impairments of goods that are subject to retention of title. The purchaser already consents to assign any claims arising from the resale of goods subject to retention of title to the vendor and authorises the vendor to col-lect said claims. in spite of the aforementioned agreement, the purchaser remains authorised to collect any claims until we revoke such authorisation in writing. Upon our request, the purchaser must notify the debtor of the assignment of the claim. The vendor is entitled to give notice of this assign-ment. The reten-tion of title also extends to the full value of any products created by processing, blending or combining our goods. in this respect, we are deemed to be the manufacturer, and the purchaser shall exempt us from any obligations arising therefrom. in the event that third parties retain a right of title to goods used in the processing, blending or combination with our goods, we acquire co-title to the newly created products in the ratio of the invoice values of the processed goods. We are authorised to access the purchaser’s warehouse or to commission an agent to access the purchaser’s warehouse for the purpose of inspecting the goods that are subject to retention of title. We undertake to release the retention of title at our discretion if the value of the same exceeds the claims to be secured by 20%.

Notification of defects: Complaints relating to shipped goods will only be considered if submitted within 8 days from receipt of the goods. The purchaser must provide proof to substantiate any complaint. in the event that we acknowledge the defect, we reserve the right to decide whether to accept the return of the defective merchandise in return for the revocation of the purchase contract or to replace it free of charge within a reasonable period or to credit the reduction in the value of the goods. Warranties for defects can only be accepted if such defects have demonstrably been caused by circumstances occurring prior to the transfer of risk. The war-ranty period is limited to a maximum of 12 months following the transfer of risk. We must be notified of any defects in writing as soon as they are detected. returns will only be accepted if agreed in advance.Claims for damages asserted by the purchaser are excluded, irrespective of the legal grounds on which they are asserted and in particular in respect of any violations of contractual obligations and impermissible actions. This does not apply to statutory liability obligations, e.g. pursuant to the Product Liability Act, in cases of premeditation or gross negligence, if life, limb or health are threatened or material contractual obligations violated. Compensation for violations of material contractual obligations is, however, limited to the contract-specific, foreseeable damage unless such dam-age is caused by premeditation or gross negligence or liability must be assumed for injury to life, limb or health. The aforementioned regulations do not constitute a reversal of the burden of proof to the disadvantage of the purchaser.

returns: Purchasers may only cancel an order in part or whole with our prior consent. in such cases, we reserve the right to charge 30% of the value of the goods as partial reimbursement of our costs. Goods that have already been delivered may only be returned – if at all – in a re-sellable con-dition and in their original packaging. Custom-made products, luminaire signs and safety luminaires, merchandise procured at the request of the customer, incandescent and fluorescent lamps and electronic switching equipment may not be returned. in the event that we consent to the return, we will issue a return slip which must be included with the return. Standard and undamaged goods in original packaging will be credited at a maximum of 70% of the invoiced price. All reconditioning, freight and packaging costs must, moreover, be borne by the purchaser. returns are always shipped at the risk of the customer returning the merchandise. No credit will be issued for goods returned without a written declaration of consent by rZB. Such goods may be disposed of at the sender’s expense.

Weights, dimensions, technical specifications and illustrations have been prepared with all due care (E&OE) but are not binding since the construction, design and technical specifications of our products are con-stantly changing to keep pace with technical progress.

Payment terms: invoices are payable net and without any deductions within 30 days from invoice date. We grant a 2% discount on the net value of the merchandise if invoices are paid in advance or within 8 days from invoice date. in the event of delayed payment, we reserve the right to charge default interest at a rate of 5% above the applicable base rate pursuant to Section 1 Discount rate Transition Act. A processing sur-charge of Euro 10 will be levied on orders with a value of Euro 50 or less. in the event of default, the entire amounts receivable by us become due for payment immediately.

Disposal: Non-private purchasers undertake to ensure the disposal of the purchased products in accordance with the provisions of the German Electrical and Electronic Equipment Act (ElektroG). in the event of resale, the purchaser transfers this obligation to their contractual partner. EU customers not resident in Germany: Please note the implementation of the WEEE Directive in national legislation.

Place of performance and general court of jurisdiction for deliver-ies and payments and for all other obligations is, without exception, Bamberg. The General Terms and Conditions of Supply for products and services supplied by the electrical industry apply. Please do not hesitate to contact us if you require a copy.

Page 284: Emergency Lighting A1

282

No. Page No. Page No. Page No. Page No. PageNo. Page

ArTiCLE NUMBEr iNDEX

671207.004.72 177671207.004.81 177671207.004.82 177671207.752 177671207.752.71 177671207.752.72 177671207.752.81 177671207.752.82 177671207.754 177671207.754.71 177671207.754.72 177671207.754.81 177671207.754.82 177671208.002 177671208.002.71 177671208.002.72 177671208.002.81 177671208.002.82 177671208.004 177671208.004.71 177671208.004.72 177671208.004.81 177671208.004.82 177671209.752 177671209.752.71 177671209.752.72 177671209.752.81 177671209.752.82 177671209.754 177671209.754.71 177671209.754.72 177671209.754.81 177671209.754.82 177671211.002 177671211.002.71 177671211.002.72 177671211.002.81 177671211.002.82 177671211.004 177671211.004.71 177671211.004.72 177671211.004.81 177671211.004.82 177671211.752 177671211.752.71 177671211.752.72 177671211.752.81 177671211.752.82 177671211.754 177671211.754.71 177671211.754.72 177671211.754.81 177671211.754.82 177671213.002 177671213.002.71 177671213.002.72 177671213.002.81 177671213.002.82 177671213.004 177671213.004.71 177671213.004.72 177671213.004.81 177671213.004.82 177

09-6019.000 11709-6202.009 15109-6230.000 15109-6284.000 11509-6285.000 11509-6286.000 11509-6287.000 11509-6288.000 11509-6289.000 11509-6290.000 11509-6291.000 11509-6292.000 11509-6293.000 11509-6294.000 11509-6295.000 115

22125.002 63, 19722125.003 63, 197

65133 5565936 11165938 11165940 11165942 111

67000.0.152 14367004.009 6767005.009 6767006.009 67

671001.752 37671001.752.03 37671001.752.04 37671001.754 37671001.754.03 37671001.754.04 37671003.752 37671003.752.03 37671003.752.04 37671003.754 37671003.754.03 37671003.754.04 37671005.752 37671005.752.03 37671005.752.04 37671005.754 37671005.754.03 37671005.754.04 37671009.752 43671009.752.03 43671009.752.04 43671011.752 43671011.752.03 43671011.752.04 43671013.752 43671013.752.03 43671013.752.04 43671017.752 42671017.752.03 42671017.752.04 42671023.752 42671023.752.03 42671023.752.04 42671045.002 45

671045.002.03 45671045.002.04 45671045.004 45671045.004.03 45671045.004.04 45671045.752 45671045.752.03 45671045.752.04 45671045.754 45671045.754.03 45671045.754.04 45671049.002 45671049.002.03 45671049.002.04 45671049.004 45671049.004.03 45671049.004.04 45671049.752 45671049.752.03 45671049.752.04 45671049.754 45671049.754.03 45671049.754.04 45671053.002 45671053.002.03 45671053.002.04 45671053.004 45671053.004.03 45671053.004.04 45671053.752 45671053.752.03 45671053.752.04 45671053.754 45671053.754.03 45671053.754.04 45671057.002 45671057.002.03 45671057.002.04 45671057.004 45671057.004.03 45671057.004.04 45671057.752 45671057.752.03 45671057.752.04 45671057.754 45671057.754.03 45671057.754.04 45671061.002 46671061.002.03 46671061.002.04 46671061.004 46671061.004.03 46671061.004.04 46671061.752 46671061.752.03 46671061.752.04 46671061.754 46671061.754.03 46671061.754.04 46671065.002 46671065.002.03 46671065.002.04 46671065.004 46

671065.004.03 46671065.004.04 46671065.752 46671065.752.03 46671065.752.04 46671065.754 46671065.754.03 46671065.754.04 46671069.002 46671069.002.03 46671069.002.04 46671069.004 46671069.004.03 46671069.004.04 46671069.752 46671069.752.03 46671069.752.04 46671069.754 46671069.754.03 46671069.754.04 46671073.002 46671073.002.03 46671073.002.04 46671073.004 46671073.004.03 46671073.004.04 46671073.752 46671073.752.03 46671073.752.04 46671073.754 46671073.754.03 46671073.754.04 46671077.002 47671077.002.03 47671077.002.04 47671077.004 47671077.004.03 47671077.004.04 47671077.752 47671077.752.03 47671077.752.04 47671077.754 47671077.754.03 47671077.754.04 47671081.002 47671081.002.03 47671081.002.04 47671081.004 47671081.004.03 47671081.004.04 47671081.752 47671081.752.03 47671081.752.04 47671081.754 47671081.754.03 47671081.754.04 47671085.002 47671085.002.03 47671085.002.04 47671085.004 47671085.004.03 47671085.004.04 47671085.752 47

671085.752.03 47671085.752.04 47671085.754 47671085.754.03 47671085.754.04 47671089.002 47671089.002.03 47671089.002.04 47671089.004 47671089.004.03 47671089.004.04 47671089.752 47671089.752.03 47671089.752.04 47671089.754 47671089.754.03 47671089.754.04 47671093.752 109671093.752.03 109671093.752.04 109671095.912 99671095.912.03 99671095.912.04 99

671107.912 107671107.912.03 107671107.912.04 107671107.913 107671107.913.03 107671107.913.04 107671109.912 107671109.912.03 107671109.912.04 107671109.913 107671109.913.03 107671109.913.04 107671111.752 63671111.752.03 63671111.752.04 63671111.753 63671111.753.03 63671111.753.04 63671112.922 99671112.922.03 99671112.922.04 99671113.752 63671113.752.03 63671113.752.04 63671113.753 63671113.753.03 63671113.753.04 63671116.750 67671148.000 16671178.752 169671178.752.71 169671178.752.72 169671178.752.81 169671178.752.82 169671178.754 169671178.754.71 169671178.754.72 169671178.754.81 169671178.754.82 169

671179.752 169671179.752.71 169671179.752.72 169671179.752.81 169671179.752.82 169671179.754 169671179.754.71 169671179.754.72 169671179.754.81 169671179.754.82 169671180.752 169671180.752.71 169671180.752.72 169671180.752.81 169671180.752.82 169671180.754 169671180.754.71 169671180.754.72 169671180.754.81 169671180.754.82 169671181.752 175671181.752.71 175671181.752.72 175671181.752.81 175671181.752.82 175671182.752 175671182.752.71 175671182.752.72 175671182.752.81 175671182.752.82 175671183.752 175671183.752.71 175671183.752.72 175671183.752.81 175671183.752.82 175671184.752 175671184.752.71 175671184.752.72 175671184.752.81 175671184.752.82 175671185.752 174671185.752.71 174671185.752.72 174671185.752.81 174671185.752.82 174671186.752 174671186.752.71 174671186.752.72 174671186.752.81 174671186.752.82 174671188.752 174671188.752.71 174671188.752.72 174671188.752.81 174671188.752.82 174

671207.002 177671207.002.71 177671207.002.72 177671207.002.81 177671207.002.82 177671207.004 177671207.004.71 177

Page 285: Emergency Lighting A1

283

No. PageNo. Page No. Page No. Page No. PageNo. Page

ArTiCLE NUMBEr iNDEX

671351.752.04 47671351.754 47671351.754.03 47671351.754.04 47671357.002 177671357.004 177671359.002 177671359.002.71 177671359.002.72 177671359.002.81 177671359.002.82 177671359.004 177671359.004.71 177671359.004.72 177671359.004.81 177671359.004.82 177671359.752 177671359.752.71 177671359.752.72 177671359.752.81 177671359.752.82 177671359.754 177671359.754.71 177671359.754.72 177671359.754.81 177671359.754.82 177671361.002 178671361.004 178671363.002 178671363.002.71 178671363.002.72 178671363.002.81 178671363.002.82 178671363.004 178671363.004.71 178671363.004.72 178671363.004.81 178671363.004.82 178671363.752 178671363.752.71 178671363.752.72 178671363.752.81 178671363.752.82 178671363.754 178671363.754.71 178671363.754.72 178671363.754.81 178671363.754.82 178671365.002 179671365.004 179671367.002 179671367.002.71 179671367.002.72 179671367.002.81 179671367.002.82 179671367.004 179671367.004.71 179671367.004.72 179671367.004.81 179671367.004.82 179671367.752 179671367.752.71 179671367.752.72 179

671223.752.71 178671223.752.72 178671223.752.81 178671223.752.82 178671223.754 178671223.754.71 178671223.754.72 178671223.754.81 178671223.754.82 178671227.002 178671227.002.71 178671227.002.72 178671227.002.81 178671227.002.82 178671227.004 178671227.004.71 178671227.004.72 178671227.004.81 178671227.004.82 178671227.752 178671227.752.71 178671227.752.72 178671227.752.81 178671227.752.82 178671227.754 178671227.754.71 178671227.754.72 178671227.754.81 178671227.754.82 178671229.002 179671229.002.71 179671229.002.72 179671229.002.81 179671229.002.82 179671229.004 179671229.004.71 179671229.004.72 179671229.004.81 179671229.004.82 179671229.752 179671229.752.71 179671229.752.72 179671229.752.81 179671229.752.82 179671229.754 179671229.754.71 179671229.754.72 179671229.754.81 179671229.754.82 179671231.002 179671231.002.71 179671231.002.72 179671231.002.81 179671231.002.82 179671231.004 179671231.004.71 179671231.004.72 179671231.004.81 179671231.004.82 179671231.752 179671231.752.71 179671231.752.72 179671231.752.81 179

671231.752.82 179671231.754 179671231.754.71 179671231.754.72 179671231.754.81 179671231.754.82 179671233.002 179671233.002.71 179671233.002.72 179671233.002.81 179671233.002.82 179671233.004 179671233.004.71 179671233.004.72 179671233.004.81 179671233.004.82 179671233.752 179671233.752.71 179671233.752.72 179671233.752.81 179671233.752.82 179671233.754 179671233.754.71 179671233.754.72 179671233.754.81 179671233.754.82 179671235.002 179671235.002.71 179671235.002.72 179671235.002.81 179671235.002.82 179671235.004 179671235.004.71 179671235.004.72 179671235.004.81 179671235.004.82 179671235.752 179671235.752.71 179671235.752.72 179671235.752.81 179671235.752.82 179671235.754 179671235.754.71 179671235.754.72 179671235.754.81 179671235.754.82 179671236.912 185671236.912.71 185671236.912.81 185671236.912.82 185671237.912 185671237.912.71 185671237.912.81 185671237.912.82 185671238.912 185671238.912.71 185671238.912.81 185671238.912.82 185671247.912 197671247.912.71 197671247.912.72 197671247.912.81 197671247.912.82 197

671213.752 177671213.752.71 177671213.752.72 177671213.752.81 177671213.752.82 177671213.754 177671213.754.71 177671213.754.72 177671213.754.81 177671213.754.82 177671215.002 178671215.002.71 178671215.002.72 178671215.002.81 178671215.002.82 178671215.004 178671215.004.71 178671215.004.72 178671215.004.81 178671215.004.82 178671215.752 178671215.752.71 178671215.752.72 178671215.752.81 178671215.752.82 178671215.754 178671215.754.71 178671215.754.72 178671215.754.81 178671215.754.82 178671217.002 178671217.002.71 178671217.002.72 178671217.002.81 178671217.002.82 178671217.004 178671217.004.71 178671217.004.72 178671217.004.81 178671217.004.82 178671217.752 178671217.752.71 178671217.752.72 178671217.752.81 178671217.752.82 178671217.754 178671217.754.71 178671217.754.72 178671217.754.81 178671219.752 42671219.752.03 42671219.752.04 42671223.002 178671223.002.71 178671223.002.72 178671223.002.81 178671223.002.82 178671223.004 178671223.004.71 178671223.004.72 178671223.004.81 178671223.004.82 178671223.752 178

671247.913 197671247.913.71 197671247.913.72 197671247.913.81 197671247.913.82 197671248.912 197671248.912.71 197671248.912.72 197671248.912.81 197671248.912.82 197671248.913 197671248.913.71 197671248.913.72 197671248.913.81 197671248.913.82 197671253.002 189671253.003 189671254.912 189671254.913 189671256.002 177671256.004 177671258.002 177671258.004 177671260.002 177671260.004 177671262.002 177671262.004 177671264.002 178671264.004 178671266.002 178671266.004 178671268.002 178671268.004 178671270.002 178671270.004 178671272.002 179671272.004 179671274.002 179671274.004 179671276.002 179671276.004 179671278.002 179671278.004 179671283.002 185671284.002 185671285.002 185671286.002 185671287.912 185671287.912.71 185671287.912.81 185671287.912.82 185671288.002 185671289.912 185671289.912.71 185671289.912.81 185671289.912.82 185671290.752 197671290.752.71 197671290.752.72 197671290.752.81 197671290.752.82 197671290.753 197671290.753.71 197

671290.753.72 197671290.753.81 197671290.753.82 197671291.752 197671291.752.71 197671291.752.72 197671291.752.81 197671291.752.82 197671291.753 197671291.753.71 197671291.753.72 197671291.753.81 197671291.753.82 197

671308.002 185671309.912 185671309.912.71 185671309.912.81 185671309.912.82 185671311.752 42671311.752.03 42671311.752.04 42671312.752 174671312.752.71 174671312.752.72 174671312.752.81 174671312.752.82 174671315.000 16671321.752 56671321.752.03 56671321.752.04 56671343.002 45671343.002.03 45671343.002.04 45671343.004 45671343.004.03 45671343.004.04 45671343.752 45671343.752.03 45671343.752.04 45671343.754 45671343.754.03 45671343.754.04 45671347.002 46671347.002.03 46671347.002.04 46671347.004 46671347.004.03 46671347.004.04 46671347.752 46671347.752.03 46671347.752.04 46671347.754 46671347.754.03 46671347.754.04 46671351.002 47671351.002.03 47671351.002.04 47671351.004 47671351.004.03 47671351.004.04 47671351.752 47671351.752.03 47

Page 286: Emergency Lighting A1

284

No. Page No. Page No. Page No. Page No. PageNo. Page

ArTiCLE NUMBEr iNDEX

671717.752.04 42671718.752 97671718.752.03 97671718.752.04 97671719.752 97671719.752.03 97671719.752.04 97671722.004 165671722.004.71 165671722.004.72 165671722.004.81 165671722.004.82 165671735.922 105671735.922.03 105671735.922.04 105671735.9231 105671735.9231.03 105671735.9231.04 105671735.924 105671735.924.03 105671735.924.04 105671736.004 164671736.004.71 164671736.004.72 164671736.004.81 164671736.004.82 164671737.004 165671737.004.71 165671737.004.72 165671737.004.81 165671737.004.82 165671738.004 164671738.004.71 164671738.004.72 164671738.004.81 164671738.004.82 164671739.004 164671739.004.71 164671739.004.72 164671739.004.81 164671739.004.82 164671740.004 165671740.004.71 165671740.004.72 165671740.004.81 165671740.004.82 165671742.004 30671742.004.03 30671742.004.04 30671744.004 31671744.004.03 31671744.004.04 31671746.004 30671746.004.03 30671746.004.04 30671748.004 31671748.004.03 31671748.004.04 31671750.004 30671750.004.03 30671750.004.04 30671752.004 31671752.004.03 31

671560.002.04 39671574.752 56671574.752.03 56671574.752.04 56671585.862.1 89671585.862.1.03 89671585.862.1.04 89671586.752 43671586.752.03 43671586.752.04 43671587.962.1 89671587.962.1.03 89671587.962.1.04 89671588.752 42671588.752.03 42671588.752.04 42671590.752 41671590.752.03 41671590.752.04 41671592.752 41671592.752.03 41671592.752.04 41671594.752 41671594.752.03 41671594.752.04 41671596.752 41671596.752.03 41671596.752.04 41671597.752 173671597.752.71 173671597.752.72 173671597.752.81 173671597.752.82 173671598.752 173671598.752.71 173671598.752.72 173671598.752.81 173671598.752.82 173671599.752 173671599.752.71 173671599.752.72 173671599.752.81 173671599.752.82 173

671600.752 173671600.752.71 173671600.752.72 173671600.752.81 173671600.752.82 173671601.002 187671601.002.81 187671601.002.82 187671601.922 187671601.922.71 187671601.922.72 187671601.922.81 187671602.922 187671602.922.71 187671602.922.72 187671602.922.81 187671602.922.82 187671605.922 53671605.922.03 53

671367.752.81 179671367.752.82 179671367.754 179671367.754.71 179671367.754.72 179671367.754.81 179671367.754.82 179671368.752 51671368.752.03 51671368.752.04 51671370.752 51671370.752.03 51671370.752.04 51671372.002 183671373.752 183671373.752.71 183671373.752.72 183671373.752.81 183671373.752.82 183671374.912 183671374.912.71 183671374.912.72 183671374.912.81 183671374.912.82 183671375.002 183671376.752 183671376.752.71 183671376.752.72 183671376.752.81 183671376.752.82 183671377.912 183671377.912.71 183671377.912.72 183671377.912.81 183671377.912.82 183671378.002 183671379.752 183671379.752.71 183671379.752.72 183671379.752.81 183671379.752.82 183671380.912 183671380.912.71 183671380.912.72 183671380.912.81 183671380.912.82 183671381.002 183671382.752 183671382.752.71 183671382.752.72 183671382.752.81 183671382.752.82 183671383.912 183671383.912.71 183671383.912.72 183671383.912.81 183671383.912.82 183671384.002 190671386.912 190671386.912.71 190671386.912.72 190671386.912.81 190671386.912.82 190

671387.922 190671387.922.71 190671387.922.72 190671387.922.81 190671387.922.82 190

671422.912 99671422.912.03 99671422.912.04 99671423.912 93671423.912.03 93671423.912.04 93671425.912 101671425.912.03 101671425.912.04 101671427.912 103671427.912.03 103671427.912.04 103671446.752 109671446.752.03 109671446.752.04 109671447.752 43671447.752.03 43671447.752.04 43671455.962 95671455.962.03 95671455.962.04 95671456.952 95671456.952.03 95671456.952.04 95671466.009 23671467.752 51671467.752.03 51671467.752.04 51671493.982 95671493.982.03 95671493.982.04 95671494.862 95671494.862.03 95671494.862.04 95671495.962 91671495.962.03 91671495.962.04 91671496.952 91671496.952.03 91671496.952.04 91671497.982 91671497.982.03 91671497.982.04 91671498.862 91671498.862.03 91671498.862.04 91

671501.004 29671501.004.03 29671501.004.04 29671502.004 29671502.004.03 29671502.004.04 29671503.004 163671503.004.71 163671503.004.72 163671503.004.81 163671503.004.82 163

671504.004 163671504.004.71 163671504.004.72 163671504.004.81 163671504.004.82 163671515.752 58671515.752.03 58671515.752.04 58671517.752 58671517.752.03 58671517.752.04 58671518.004 29671518.004.03 29671518.004.04 29671519.004 163671519.004.71 163671519.004.72 163671519.004.81 163671519.004.82 163671520.002 56671521.002 95671521.002.03 95671521.002.04 95671531.952.1 89671531.952.1.03 89671531.952.1.04 89671546.002 29671546.002.03 29671546.002.04 29671546.004 29671546.004.03 29671546.004.04 29671546.122 29671546.122.03 29671546.122.04 29671546.124 29671546.124.03 29671546.124.04 29671547.002 163671547.004 163671547.122 163671547.124 163671555.002 171671555.002.71 171671555.002.81 171671555.002.82 171671556.002 171671556.002.71 171671556.002.72 171671556.002.81 171671556.002.82 171671557.002 171671557.002.71 171671557.002.81 171671557.002.82 171671558.002 39671558.002.03 39671558.002.04 39671559.002 39671559.002.03 39671559.002.04 39671560.002 39671560.002.03 39

671605.922.04 53671606.922 53671606.922.03 53671606.922.04 53671607.002 171671607.002.71 171671607.002.72 171671607.002.81 171671607.002.82 171671608.752 61671609.752 61671609.752.03 61671609.752.04 61671611.000 16671612.922 187671612.922 187671612.922.71 187671612.922.71 187671612.922.72 187671612.922.72 187671612.922.81 187671612.922.81 187671612.922.82 187671612.922.82 187671614.922 53671614.922.03 53671614.922.04 53671615.002 39671615.002.03 39671615.002.04 39671616.759 235671616.759.71 235671616.759.72 235671616.759.81 235671616.759.82 235671617.759 235671617.759.71 235671617.759.72 235671617.759.81 235671617.759.82 235671618.752 56671619.752 58671620.752 58671629.752 192671629.752.71 192671629.752.72 192671629.752.81 192671629.752.82 192671630.752 192671630.752.71 192671630.752.72 192671630.752.81 192671630.752.82 192671639.752 56

671700.342.1 89671700.342.1.03 89671700.342.1.04 89671707.002 57671707.002.03 57671707.002.04 57671717.752 42671717.752.03 42

Page 287: Emergency Lighting A1

285

No. PageNo. Page No. Page No. Page No. PageNo. Page

ArTiCLE NUMBEr iNDEX

671907.002.03 59671907.002.04 59671908.002 57671908.002.04 57671909.002 57671909.002.04 57671911.952.1 89671911.952.1.03 89671911.952.1.04 89671912.004.03 31671912.004.04 31671913.004 31671913.004.03 31671913.004.04 31671914.004 31671914.004.03 31671914.004.04 31671915.004 33671916.002 203671917.002 73671917.002.07 73671918.002 73671918.002.07 73671919.002 199671919.002.71 199671919.002.72 199671919.002.81 199671919.002.82 199671920.002 69671920.002.07 69671921.002 69671921.002.07 69671922.004 161671922.004.71 161671922.004.72 161671922.004.81 161671922.004.82 161671923.004 161671923.004.71 161671923.004.72 161671923.004.81 161671923.004.82 161671927.002 71671927.002.07 71671928.002 71671928.002.07 71671929.002 71671929.002.07 71671930.002 71671930.002.07 71671931.002 71671931.002.07 71671932.002 71671932.002.07 71671933.002 71671933.002.07 71671934.002 71671934.002.07 71671936.002 201671938.004 161671938.004.71 161671938.004.72 161671938.004.81 161

671792.002 59671792.002.03 59671792.002.04 59671793.002 193671793.002.71 193671793.002.72 193671793.002.81 193671793.002.82 193671799.802 219671799.802.71 219671799.802.72 219671799.802.81 219671799.802.82 219

671800.802 219671800.802.71 219671800.802.72 219671800.802.81 219671800.802.82 219671801.002 219671801.002.71 219671801.002.72 219671801.002.81 219671801.002.82 219671802.862 87671802.862.03 87671802.862.04 87671803.862 87671803.862.03 87671803.862.04 87671817.009 55671819.002 59671819.002.03 59671819.002.04 59671820.002 193671820.002.71 193671820.002.72 193671820.002.81 193671820.002.82 193671822.002 187671822.002.71 187671822.002.71 187671822.002.72 187671822.002.81 187671822.002.81 187671822.002.82 187671823.000 19671824.009 111671826.002 187671826.002.71 187671826.002.72 187671826.002.81 187671826.002.82 187671835.002 207671835.002.81 207671835.002.82 207671836.002 75671837.002 205671837.002.82 205671838.002 75671839.002 205671839.002.82 205671840.002 75

671841.002 205671841.002.82 205671842.0031 35671843.0031 167671843.0031.82 167671846.0031 35671847.0031 167671847.0031.82 167671854.002 207671854.002.81 207671854.002.82 207671857.962 85671857.962.03 85671857.962.04 85671858.952 85671858.952.03 85671858.952.04 85671859.962 85671859.962.03 85671859.962.04 85671860.952 85671860.952.03 85671860.952.04 85671869.962 217671869.962.71 217671869.962.72 217671869.962.81 217671869.962.82 217671870.952 217671870.952.71 217671870.952.72 217671870.952.81 217671870.952.82 217671871.962 217671871.962.71 217671871.962.72 217671871.962.81 217671871.962.82 217671872.952 217671872.952.71 217671872.952.72 217671872.952.81 217671872.952.82 217671873.924 77671873.924.03 77671873.924.04 77671874.964 77671874.964.03 77671874.964.04 77671875.924 77671875.924.03 77671875.924.04 77671876.964 77671876.964.03 77671876.964.04 77671877.924 209671877.924.71 209671877.924.72 209671877.924.81 209671877.924.82 209671878.964 209671878.964.71 209671878.964.72 209

671752.004.04 31671774.752 195671774.752.71 195671774.752.72 195671774.752.81 195671774.752.82 195671775.002 191671775.002.71 191671775.002.72 191671775.002.81 191671775.002.82 191671776.752 195671776.752.71 195671776.752.72 195671776.752.81 195671776.752.82 195671777.862 87671777.862.03 87671777.862.04 87671778.862 87671778.862.03 87671778.862.04 87671779.862 87671779.862.03 87671779.862.04 87671780.002 57671780.002.03 57671780.002.04 57671781.002 219671781.002.71 219671781.002.72 219671781.002.81 219671781.002.82 219671781.004 219671781.004.71 219671781.004.72 219671781.004.81 219671781.004.82 219671782.002 191671782.002.71 191671782.002.72 191671782.002.81 191671782.002.82 191671790.802 219671790.802.71 219671790.802.72 219671790.802.81 219671790.802.82 219671790.804 219671790.804.71 219671790.804.72 219671790.804.81 219671790.804.82 219671791.802 219671791.802.71 219671791.802.72 219671791.802.81 219671791.802.82 219671791.804 219671791.804.71 219671791.804.72 219671791.804.81 219671791.804.82 219

671878.964.81 209671878.964.82 209671879.924 209671879.924.71 209671879.924.72 209671879.924.81 209671879.924.82 209671880.964 209671880.964.71 209671880.964.72 209671880.964.81 209671880.964.82 209671881.834 79671881.834.03 79671881.834.04 79671882.834 79671882.834.03 79671882.834.04 79671883.834 211671883.834.71 211671883.834.72 211671883.834.81 211671883.834.82 211671884.834 211671884.834.71 211671884.834.72 211671884.834.81 211671884.834.82 211671885.822 213671885.822.71 213671885.822.72 213671885.822.81 213671885.822.82 213671885.824 213671885.824.71 213671885.824.72 213671885.824.81 213671885.824.82 213671886.842 213671886.842.71 213671886.842.72 213671886.842.81 213671886.842.82 213671886.844 213671886.844.71 213671886.844.72 213671886.844.81 213671886.844.82 213671887.832 213671887.832.71 213671887.832.72 213671887.832.81 213671887.832.82 213671887.834 213671887.834.71 213671887.834.72 213671887.834.81 213671887.834.82 213671888.822 215671888.822.71 215671888.822.72 215671888.822.81 215671888.822.82 215

671888.824 215671888.824.71 215671888.824.72 215671888.824.81 215671888.824.82 215671889.842 215671889.842.71 215671889.842.72 215671889.842.81 215671889.842.82 215671889.844 215671889.844.71 215671889.844.72 215671889.844.81 215671889.844.82 215671890.832 215671890.832.71 215671890.832.72 215671890.832.81 215671890.832.82 215671890.834 215671890.834.71 215671890.834.72 215671890.834.81 215671890.834.82 215671891.842 81671891.842.03 81671891.842.04 81671891.844 81671891.844.03 81671891.844.04 81671892.842 81671892.842.03 81671892.842.04 81671892.844 81671892.844.03 81671892.844.04 81671893.842 83671893.842.03 83671893.842.04 83671893.844 83671893.844.03 83671893.844.04 83671894.842 83671894.842.03 83671894.842.04 83671894.844 83671894.844.03 83671894.844.04 83671895.004 30671895.004.03 30671895.004.04 30671896.004 30671896.004.03 30671896.004.04 30671897.004 30671897.004.03 30671897.004.04 30

671906.002 59671906.002.03 59671906.002.04 59671907.002 59

Page 288: Emergency Lighting A1

286

No. Page No. Page No. Page No. Page No. PageNo. Page

ArTiCLE NUMBEr iNDEX

985021 156985054 157985055 157985107 124985138 149985147 149985182 157985195 156985212 143985213 143985214 143985215 143985216 143985217 143985218 143985238 124985256 149985272 152985273 153985274 153985279 154985280 154985288 134985289 134985290 134985291 135985292 135985293 135985364 149985366 139985367 139985368 139985369 139985370 139985371 139985372 139985373 139985374 139985375 139985377 139985405 11985406 11

991112 61991116 53991117 53991118 53

99350 27299350.1 27299351 272

981144.002 56981158.003 116981158.003.03 116981158.003.04 116981159.003 116981159.003.03 116981159.003.04 116981160.003 116981160.003.03 116981160.003.04 116981161.003 116981161.003.03 116981161.003.04 116981162.002 116981162.002.03 116981162.002.04 116981163.002 116981163.002.03 116981163.002.04 116981164.002 116981164.002.03 116981164.002.04 116981165.002 116981165.002.03 116981165.002.04 116981167.002 41981168.002 37

981348.002 155981352.003 150981353.009 150

981485.002 58981489.002 37

981502.000 118981504.000 118981506.000 118981508.000 118981510.000 118981512.000 118981581.004 29981583.002 58981586.002 169

981639.010 29981639.020 163981639.030 29981639.040 29981639.060 163981640.000 31981647.000 165981647.010 31981647.020 165981647.030 31981647.040 31981653.002 77981653.004 77981653.102 77981653.104 77981656.000 77981659.002 79981659.004 79981660.002 79981660.004 79

671938.004.82 161671939.004 161671939.004.71 161671939.004.72 161671939.004.81 161671939.004.82 161671940.004 161671940.004.71 161671940.004.72 161671940.004.81 161671940.004.82 161671941.004 161671941.004.71 161671941.004.72 161671941.004.81 161671941.004.82 161671942.004 161671942.004.71 161671942.004.72 161671942.004.81 161671942.004.82 161671943.004 27671943.004.04 27671943.004.07 27671944.004 27671944.004.04 27671944.004.07 27671945.004 27671945.004.04 27671945.004.07 27671946.004 27671946.004.04 27671946.004.07 27671947.004 27671947.004.04 27671947.004.07 27671948.004 27671948.004.04 27671948.004.07 27671949.004 27671949.004.04 27671949.004.07 27671950.002 201671950.002.71 201671950.002.72 201671950.002.81 201671950.002.82 201671951.002 201671951.002.71 201671951.002.72 201671951.002.81 201671951.002.82 201671952.002.1 221671952.002.1.71 221671952.002.1.72 221671952.002.1.81 221671952.002.1.82 221671952.002.2 221671952.002.2.71 221671952.002.2.72 221671952.002.2.81 221671952.002.2.82 221671953.922 225

671953.922.71 225671953.922.72 225671953.922.81 225671953.922.82 225671954.842 225671954.842.71 225671954.842.72 225671954.842.81 225671954.842.82 225671955.952 225671955.952.71 225671955.952.72 225671955.952.81 225671955.952.82 225671956.952 225671956.952.71 225671956.952.72 225671956.952.81 225671956.952.82 225671957.002 225671957.002.71 225671957.002.72 225671957.002.81 225671957.002.82 225671958.962.1 223671958.962.1.71 223671958.962.1.72 223671958.962.1.81 223671958.962.1.82 223671958.962.2 223671958.962.2.71 223671958.962.2.72 223671958.962.2.81 223671958.962.2.82 223671959.952.1 223671959.952.1.71 223671959.952.1.72 223671959.952.1.81 223671959.952.1.82 223671959.952.2 223671959.952.2.71 223671959.952.2.72 223671959.952.2.81 223671959.952.2.82 223671963.962 231671963.963 231671964.962 229671964.9631 229671964.964 229671965.952 229671965.9531 229671965.954 229671966.962 229671966.9631 229671966.964 229671967.952 229671967.9531 229671967.954 229671968.962 229671968.9631 229671968.964 229671969.952 229671969.9531 229

671969.954 229671970.962 229671970.9631 229671970.964 229671971.952 229671971.9531 229671971.954 229671972.922 231671972.923 231671973.962 231671973.963 231671974.813 233671974.813.71 233671974.813.72 233671974.813.81 233671974.813.82 233671975.912 237671975.913 237671975.919 237671976.912 237671976.913 237671976.919 237671977.0031 239671977.004 239

67923.750 6567924.750 65

90-3757.002 3790-3757.004 3790-4013.002 6390-4013.003 6390-4164.002 56

98102.002/176 7798102.002/215 79981095.000 229981098.002 225981098.004 225981098.0042 225981098.005 225981098.0061 225981098.0076 225981098.0082 225981098.009 225

981100.002 225981100.004 225981100.0042 225981100.005 225981100.0061 225981100.0076 225981100.0082 225981100.009 225981127.003 117981128.002 117981129.002 225981129.004 225981129.0042 225981129.005 225981129.0061 225981129.0076 225981129.0082 225981129.009 225

981662.000 79981678.002 213981678.004 213981685.000 29981686.000 30981687.000 31

981701.004 29981702.004 31981771.000 58981781.000 56981722.002 180981722.002.71 180981722.002.72 180981722.002.81 180981722.002.82 180981723.002 180981723.002.71 180981723.002.72 180981723.002.81 180981723.002.82 180981724.002 48981724.002.03 48981724.002.04 48981725.002 180981725.002.71 180981725.002.72 180981725.002.81 180981725.002.82 180981726.002 48981726.002.03 48981726.002.04 48981727.002 180981727.002.71 180981727.002.72 180981727.002.81 180981727.002.82 180981728.002 48981728.002.03 48981728.002.04 48981734.000 85981759.002 180981759.002.71 180981759.002.72 180981759.002.81 180981759.002.82 180981760.002 180981760.002.71 180981760.002.72 180981760.002.81 180981760.002.82 180981773.002 48981773.002.03 48981773.002.04 48981774.002 48981774.002.03 48981774.002.04 48981775.0031 35,167981776.000 35,167981777.0031 35981777.0131 167981777.0231 167

985019 156

Page 289: Emergency Lighting A1

287

No. PageNo. Page No. Page No. Page No. PageNo. Page

ALPHABETiCAL iNDEX

A

Abbreviations 272

Absence of feedback 263

Accessories (overview) 148

all CPS and LPS

systems 149-151

GV 1500 155-157

rZBeasy 155

LUXiFAir 152-154

LUXiFAirlight 152-154

Active star network 269

After sales service 289

Alphabetical index 287

Alu-Lux oval 230

Alu-rund

SC 106

CE 230

Andho (SC)

TC 80

TC iP 65 82

Andho (CE)

TC Flat 212

TC Flat iP 65 214

Anti-panic lighting 244

Arelo®

recessed downlight (SC) 84

recessed downlight (CE) 216

Article number codes

(explanation) 276

Article number index 282

B

Ballasts 273

Basic 98

Batteries 124

Batteries for group battery

system (GV 1500) 143

Battery cabinets 124

Building permit 264

Building code 264

C

Calculating the aeration

and ventilation of electrical

operation rooms 125

Centryxx

SC 74

CE 204

Central battery systems (CPS) Comparison 127

rZBbasic 128 LUXiFAir 132 LUXiFAirlight 138

Charging and charge maintenance device 124

Circuit identification signs 272

Connecting diagrams 119-121

Connecting diagrams 263

Connecting diagram for rZBeasy 202 / 204 147

Contact 289

Costs for weekly tests 261

D

DALi interface 10-13

Definition Viewing distance 242 Emergency lighting 242 Legend (pictogram) 242

Design SC 40-43 CE 172-175

Design of escape signs 262

Display SC 36 CE 168

DUO Control 154

Die-cast aluminium (Alu-Druckguss) 236

E

E 30 junction box 269

ECM module 152 (electric circuit module) 152

Edo SC 70 CE 200

Electric circuits 263

Electronic switches UE220e 150 UE220i 150 Dimming mode 151 Voltage control 151

Electrotechnical safety 273

Electrotechnical variants and additions 273

Emergency conversion kits 116

Emergency power supply unit PGVG 200 118

Energo TC 175 recessed downlight (SC) 76 recessed downlight (CE) 208

Energo TC 210

recessed downlight (SC) 78

recessed downlight (CE) 210

Escape and rescue

routes plan 265

European and international

regulations 242-246

EN 1838 242-243

EN 50171 245

EN 50172 244

EN 50272-2 245

EN 60598-2-22 246

EB 274

EVG 274

Explanation of catalogue

numbers 276

F

Flat Basic

SC 92

CE 224

Flat Basic with collar 94

Flat Polymero®

SC 88

CE 220

Flat Polymero® PC

with collar 90

Flat Polymero® PMMA 222

Flat Polymero® PC 222

Flat Polymero® rechteck

SC 96

CE 226

Flat Sign Mini/Midi

SC 38

CE 170

G

General 244

General information 273

German regulations 246-269

ASr (workplace

regulation) 265-266

BGV A8 (safe working

practices regulations) 262

DiN VDE 0100, Part 560 263

DiN VDE 0100, Part 718 263

DiN VDE 0108, Part 100 246

DiN 4844, Part 1 / Part 2 262

(M) LAr - (Model) wiring

systems directive 264

Group battery systems (LPS)

Comparison 141

rZB GV 1500 142

rZBeasy 202 / 204 144

GSUN® 2 55

GSUN® 2 LED 55

GSUN® 3 56

GSUN® 3 LED 57

GSUN® 4 58

GSUN® 4 LED 59

GSUN® S 32

H

Halyxx®

SC 28-31

CE 162-165

Hand-held LED

safety spotlight 110

Housing, fire-protected (E-30) 131

Housing with charging and

charge maintenance device 130

I

ilustris

SC 34

CE 166

information 273

information and warning

signs 245

inspections and controls

(of batteries) 245

installation example for

LUXiFAir 133

LUXiFAirlight 139

rZBbasic 129

rZBeasy 202 / 204 145

EC module 137, 152

installation example for

rZBeasy 202 / 204 146

iO Module, Light switch

setting sensor modules 153

iOM 230 for direct power

supply voltage 153

iOM 24 for potential-free

contacts 153

K

Kreis 100

L

Lamps 280

LCS-Z 194

LCS1 61

LCS3 61

SC = Self-contained safety luminaires | CE = Luminaires for central emergency power supply

Page 290: Emergency Lighting A1

288

iNDEX

LED 275

LED Halyxx®

SC 28-31

CE 162-165

Legends (pictograms)

Luminaire signs 278

Emergency escape

luminaires 277

Legends for emergency

luminaires 277

Legends for emergency escape

lighting 277

Light Case 232

Light switch setting sensor

module (LSM) 157

Linear network 269

Luminance (of safety signs) 262

Light Case 232

Lucio

SC 72

CE 202

Luminaires for

sports facilities 184

Luminaire signs

Legends (pictograms) 278

LUXiFAir 132

LUXiFAir Master 136

LUXiFAir sub distribution

board 134

LUXiFAirlight 138

LUXiFAirlight Master 140

Log book 244

M

Message and switchboard

(surface mounting) 149

Microprocessor control

and monitoring unit 130, 140

Mondana

SC 86

CE 218

Monitoring module

CONTrOL1 155

Monitoring via

DALi interface 11-13

Motifs and letterings for

luminaire signs 278-279

emergengy luminaires 277

MultiDigit® 14-16

Multivariabel

SC 50

CE 182

MWEB

monitoring module 16-18

MWEBplus 18

N

NCH complete

conversion kit 117

NCH module 117

NCH safety conversion kit 117

P

PGVG 200 118

Planning issues 268

Printer 149

Protection types 272

Protection classes 272

Power supply units 116

Power sources 263

PZ 50 22-23

r

rechteck (Universal 2) 188

rechteck 250 / 360 / 485

SC-overview 44

rechteck 250 45

rechteck 360 46

rechteck 485 47

rechteck 250 / 360 / 485

CE-overview 176

rechteck 250 177

rechteck 360 178

rechteck 485 179

remote control tableau,

type: MTB-BUS 156

rondo 102

rounded Maxi 104

rounded® extra flat 228

rZBbasic 128

rZBbasic sub distribution

board 131

rZBbasic components 130

rZBeasy 202 / 204 144

S

Safety and health signs 262

Safety-Spotlights 110

Safety marks 273

Servicing and testing 244

Signal amplifier 16

Signcube

SC 52

CE 186

SiNGLE Control 154

Symbol explanations 273

Signcube

SC 52

CE 186

SiNGLE Control 154

Solyxx 206

Space 64

Starter set 16

Special requirements for

battery rooms 245

T

Technical support 289

Tenuo

SC 26

CE 160

Test logs 263

Turia 68

Turia Z 198

TWiN control for group battery

system (GV 1500) 143

TWiN technology 155

U

Universal 2 188, 189

Universal 3 188, 190

Universal 3 LED 188, 191

Universal 4 188, 192

Universal 4 LED 188, 193

Universal changeover unit,

type: UUE 4/220 156

Universum 66

V

Varioplast i

SC 62

CE 196

Ventilation

(concerning batteries) 245

Visibility 244

W

Weatherproof battens

SC 108

CE 234

3

3-phase network monitoring

module 149

SC = Self-contained safety luminaires | CE = Luminaires for central emergency power supply

Page 291: Emergency Lighting A1

www.rzb-lighting.com

RZB Rudolf Zimmermann, Bamberg GmbH

Rheinstrasse 16, D-96052 Bamberg, Germany P.O. Box 29 40, D-96020 Bamberg, Germany

Telephone +49 951/79 09-374 Fax +49 951/79 09-212

[email protected]

www.rzb-lighting.com

CUSTOMERCONTACT

289

Page 292: Emergency Lighting A1

RZB Rudolf Zimmermann, Bamberg GmbH

Rheinstrasse 16 D-96052 Bamberg Germany

Telephone +49 951/79 09-374Fax +49 951/79 09-212

www.rzb.eu [email protected]

KAT3

9EN

emeRGency liGhTinGem

erg

ency

lig

hti

ng

A1