Upload
lamthuan
View
218
Download
0
Embed Size (px)
Citation preview
EMC Research Institute File No. FCC07-00510628
Page 2 of 18
E R I, 66-6, Jeil-Ri, Yangji-Myun, Cheoin –Gu, Yongin-Si, Gyeonggi-Do, Korea
Tel: +82-31-679-9600 Fax: +82-31-336-1184 ERI-WI-ETRF001-06 Rev.No.2
CONTENTS
1. CLIENT INFORMATION
2. LABORATORY INFORMATION
3. EQUIPMENT UNDER TEST INFORMATION (EUT)
4. TEST SPECIFICATIONS
5. TEST RESULTS SUMMARY
5.1 TEST RESULT
5.2 GERNERAL PERFORMANCE CRITERIA
5.3 CONTINUOUS DISTURBANCE VOLTAGE AT MAIN TERMINALS 5.4 RADIATED DISTURBANCE
6. PRODURCT PHOTOGRAPHS
EMC Research Institute File No. FCC07-00510628
Page 3 of 18
E R I, 66-6, Jeil-Ri, Yangji-Myun, Cheoin –Gu, Yongin-Si, Gyeonggi-Do, Korea
Tel: +82-31-679-9600 Fax: +82-31-336-1184 ERI-WI-ETRF001-06 Rev.No.2
1. CLIENT INFORMATION
The EUT has been tested by request of : Company : JEC KOREA, Ault Korea Corporation, Wendeng Jeil Electronics. Address : 26-6 Wau-Ri, BongDam-Eup, HwaSeong-Si, Kyonggi-Do, Korea. Address : Dong Shou GuangZhou Lu KaiF-aQu Wendeng-Shi ShanDong Province China. Name of contact : Jeon, Jong-nam
Telephone : +82-31-299-1281 Facsimile : +82-31-225-8502
2 LABORATORY INFORMATION
The 10 m Semi-anechoic chamber and/or EMC facilities are used for these testing. These facilities were accredited by KOLAS, EK, MIC of Korea and FCC of USA, and VCCI of Japan Address EMC RESEARCH INSTITUTE. 66-6, Jeil-Ri, Yangji-Myun, Cheoin-Gu, Yongin-Si, Gyeonggi-Do, Korea
Telephone No. : + 82-31-679-9600
Facsimile No. : + 82-31-336-1184
Registered No.
KOLAS : 111
EK : J
MIC, FCC(DoC) : KR0030
FCC Filing No. : 302567 VCCI Reg. No. : C-2363, R-2183 3 EQUIPMENT UNDER TEST INFORMATION(EUT) 3.1. Identification of the EUT
Type of equipment : AC/DC Adaptor Model name : JPOE130x48xxFxx Company : JEC KOREA, Ault Korea Corporation, Wendeng Jeil Electronics. Address : 26-6 Wau-Ri, BongDam-Eup, HwaSeong-Si, Kyonggi-Do, Korea. Address : Dong Shou GuangZhou Lu KaiF-aQu Wendeng-Shi ShanDong Province China. Name of contact : Jeon, Jong-nam
Telephone : +82-31-299-1281 Facsimile : +82-31-225-8502 Country of origin : KOREA
EMC Research Institute File No. FCC07-00510628
Page 4 of 18
E R I, 66-6, Jeil-Ri, Yangji-Myun, Cheoin –Gu, Yongin-Si, Gyeonggi-Do, Korea
Tel: +82-31-679-9600 Fax: +82-31-336-1184 ERI-WI-ETRF001-06 Rev.No.2
INPUT
* Voltage AC 100 V to 250V +/-10 %
* Line Frequency Range 47 Hz – 63 Hz
* Current 0.5 A Max. at 90 V AC input
* Protection Internal primary current fuse (1.0 A)
Inrush limiting
* Configuration IEC320-C14 Inlet, Desk Top Type
OUTPUT
* Voltage +48 V dc
The voltage potential shall be measured between any conductor
of one power pair and any conductor of the other power pair.
* Load regulation +/- 4 %
* Load condition max 0.4 A
min 0 A
* Ripple and Noise Power feeding ripple and noise: (IEEE 802.3af 33.2.8.3)
f < 500 kHz 500 mV p-p
500 Hz to 150 kHz 200 mV p-p
150 kHz to 500 kHz 150 mV p-p
500 kHz to 1 MHz 100 mV p-p
* Transient response 0.5 ms for 50 % load change typical
* Hold-up time 16 ms min @ 110 V AC / 60 Hz
* PI Pin Assignment
EMC Research Institute File No. FCC07-00510628
Page 5 of 18
E R I, 66-6, Jeil-Ri, Yangji-Myun, Cheoin –Gu, Yongin-Si, Gyeonggi-Do, Korea
Tel: +82-31-679-9600 Fax: +82-31-336-1184 ERI-WI-ETRF001-06 Rev.No.2
SAFETY APPROVALS
* Agency Listings UL60950-1, TUV/IEC EN60950-1
EMC : EN55022 / EN 55024 / EN 61000
ELECTRICAL
* Topology Switching - Fixed Frequency Flyback
* Dielectric Withstand
Hi-Pot 3,000VAC or 4,250VDC (Tied Live and Neutral) AND (Tied DC Output and Ground)
Cut-off current 10 mA. 60 s
* Spacing More than 6.4 mm Primary-Secondary
* Leakage current Less than 0.75 mA at 265 V AC 50 Hz
* Efficiency 65 % minimum
* EMI Complies with EMC Directive
* CE CE Compliant
ENVIRONMENTAL
* Operating Temperature 0 ℃ to 40 ℃ with no derating
* Storage temperature -30 ℃ to +85 ℃
* Relative humidity 5 % to 95 % non-condensing
* Altitude 0 – 10 000 feet
* Cooling Convectional - non vented case
MECHANICAL
* Case and Dimensions 107.9 mm (L) x 66.5 mm (W) x 38.6 mm (H)
* Case Material Black 95 V-0 Polycarbonate
* Cords and Connectors Dual RJ45 Jacks built into the enclosure
EMC Research Institute File No. FCC07-00510628
Page 6 of 18
E R I, 66-6, Jeil-Ri, Yangji-Myun, Cheoin –Gu, Yongin-Si, Gyeonggi-Do, Korea
Tel: +82-31-679-9600 Fax: +82-31-336-1184 ERI-WI-ETRF001-06 Rev.No.2
3.2 Additional information about the EUT
Class B, Family Models List
Sample Model Variant Model Differential point
JPOE130x48xxFxx PW180x48xxFxx Refer to the below.
Standard Model Configuration
JPOE 130 A 48 00 F K 01
1 2 3 4 5 6 7
1. Family Related Designs
2. Design Revision Changes
A to Z (Standard)
3. Output Voltage
48 V
4. Standards Output Cord Options
Number : 00-99
5. Standard Input Cord Options
F : (CLASS Ⅰ= IEC320-14)
6. Manufacturing Location
J : JEC Korea K : AULT Korea C : Wendeng Jeil Electronics
7. Custom Options (Marking, Cord etc.)
Number : 00-99
8. Family Related Designs
EMC Research Institute File No. FCC07-00510628
Page 7 of 18
E R I, 66-6, Jeil-Ri, Yangji-Myun, Cheoin –Gu, Yongin-Si, Gyeonggi-Do, Korea
Tel: +82-31-679-9600 Fax: +82-31-336-1184 ERI-WI-ETRF001-06 Rev.No.2
PUPT-130 A 01
1 2 3 1. Family Related Designs
2. Design Revision Changes A to Z(Standard)
3. Custom Options (Marking, Cord etc.)
Number : 00-99 Derivative Model Configuration (Describe the difference from the Standard Model)
PW 180 K A 48 00 F 01
1 2 3 4 5 6 7
1. Family Related Designs
2. Design Revision Changes
A to Z (Standard)
3. Output Voltage
48 V
4. Standards Output Cord Options
Number : 00-99
5. Standard Input Cord Options
F : (CLASS Ⅰ= IEC320-14)
6. Manufacturing Location
J : JEC Korea K : AULT Korea C : Wendeng Jeil Electronics
7. Custom Options (Marking, Cord etc.)
Number : 00-99 3.3 Peripheral equipment
Equipment needed for correct operation of the EUT is defined as.
Description Model No. Serial No. Manufacture
AC·DC Adaptor JPOE130x48xxFxx - JEC KOREA,
Ault Korea Corporation Wendeng Jeil Electronics
Dummy Load - - -
EMC Research Institute File No. FCC07-00510628
Page 8 of 18
E R I, 66-6, Jeil-Ri, Yangji-Myun, Cheoin –Gu, Yongin-Si, Gyeonggi-Do, Korea
Tel: +82-31-679-9600 Fax: +82-31-336-1184 ERI-WI-ETRF001-06 Rev.No.2
4 TEST SPECIFICATIONS 4.1. Standards
The standards on the EUT are given below: FCC Part 15 subpart B (class B) / Other class B digital devices & peripherals 5 TEST RESULTS SUMMARY 5.1 Test result The results in this report apply only to sample tested:
Standards Test items / Frequency Result
ANSI 63.4: 2003
1. Main Terminal disturbance voltage(150 kHz – 30 MHz) Pass
2. Radiated disturbance(30 MHz – 1 000 MHz) Pass
EMC Research Institute File No. FCC07-00510628
Page 9 of 18
E R I, 66-6, Jeil-Ri, Yangji-Myun, Cheoin –Gu, Yongin-Si, Gyeonggi-Do, Korea
Tel: +82-31-679-9600 Fax: +82-31-336-1184 ERI-WI-ETRF001-06 Rev.No.2
5.3 CONTINUOUS DISTURBANCE VOLTAGE AT MAIN TERMINALS
: Frequency range 0.15 MHz to 30 MHz
5.3.1 Operating Condition - The dummy load was supplied by the DC mains of The EUT fed by the AC mains
5.3.2 Test set-up and test procedures
AC Main
LISN
EUT R-LOAD
EMC Research Institute File No. FCC07-00510628
Page 10 of 18
E R I, 66-6, Jeil-Ri, Yangji-Myun, Cheoin –Gu, Yongin-Si, Gyeonggi-Do, Korea
Tel: +82-31-679-9600 Fax: +82-31-336-1184 ERI-WI-ETRF001-06 Rev.No.2
The conducted disturbance at mains terminals was measured with the equipment under Test(EUT) in a shield room. The EUT was connected to an artificial mains Network(LISN) placed on the floor. The EUT was placed on non-metallic table 0.8 m above the metallic, grounded floor. The distance to other metallic surface was at least 0.8 m. Amplitude measurements were performed with a quasi-peak detector and an average detector.
5.3.3 Test instrument
Instrument Model No Serial No. Makers Range (MHz) Used
Test receiver ESCS30 100021 R&S 0.009 – 2 750 O
L.I.S.N. ESH3-Z5 100030 R&S 0.009 – 30 O
ESH3-Z5 100031 R&S 0.009 – 30
Shield room 8 m/L × 6 m/W × 3.3 m/H - - - O
5.3.4 Test results
Date of test : 2007. 10. 24 An overview sweep performed with peak detector & average detectors are included in the report as test reports.
Result: Pass The measured emissions level of the EUT have found the below of the specified limit
EMC Research Institute File No. FCC07-00510628
Page 11 of 18
E R I, 66-6, Jeil-Ri, Yangji-Myun, Cheoin –Gu, Yongin-Si, Gyeonggi-Do, Korea
Tel: +82-31-679-9600 Fax: +82-31-336-1184 ERI-WI-ETRF001-06 Rev.No.2
MEASUREMNT GRAPH
EMC Research Institute File No. FCC07-00510628
Page 12 of 18
E R I, 66-6, Jeil-Ri, Yangji-Myun, Cheoin –Gu, Yongin-Si, Gyeonggi-Do, Korea
Tel: +82-31-679-9600 Fax: +82-31-336-1184 ERI-WI-ETRF001-06 Rev.No.2
EMC Research Institute File No. FCC07-00510628
Page 13 of 18
E R I, 66-6, Jeil-Ri, Yangji-Myun, Cheoin –Gu, Yongin-Si, Gyeonggi-Do, Korea
Tel: +82-31-679-9600 Fax: +82-31-336-1184 ERI-WI-ETRF001-06 Rev.No.2
EMC Research Institute File No. FCC07-00510628
Page 14 of 18
E R I, 66-6, Jeil-Ri, Yangji-Myun, Cheoin –Gu, Yongin-Si, Gyeonggi-Do, Korea
Tel: +82-31-679-9600 Fax: +82-31-336-1184 ERI-WI-ETRF001-06 Rev.No.2
EMC Research Institute File No. FCC07-00510628
Page 15 of 18
E R I, 66-6, Jeil-Ri, Yangji-Myun, Cheoin –Gu, Yongin-Si, Gyeonggi-Do, Korea
Tel: +82-31-679-9600 Fax: +82-31-336-1184 ERI-WI-ETRF001-06 Rev.No.2
5.4 RADIATED DISTURBANCE 5.4.1 Operation Condition - The dummy load was supplied by the DC mains of The EUT fed by the AC mains
5.4.2 Test set-up All readings are quasi-peak unless stated otherwise. The half-wave dipole antenna was tuned to the frequency found during Preliminary radiated measurements. The EUT, support equipment and Interconnecting cables were re-configured to the set-up to produce the Maximum emission for the frequency and were placed on top of a 0.8 m High non-metallic 1 m x 1.5 m table. The EUT, support equipment, and interconnecting cables were re-arranged and manipulated to maximize each radiated emission. The turntable containing the system was rotated the antenna height was varied 1 m - 4 m and stopped at the azimuth or height producing the maximum emission. And this device(EUT) was tested in 3 orthogonal planes. The antenna measured both horizontal and vertical polarization.
<General test set-up for radiated emissions>
0.8 m
10 m
10 m semi-anechoic chamber
EMC Research Institute File No. FCC07-00510628
Page 16 of 18
E R I, 66-6, Jeil-Ri, Yangji-Myun, Cheoin –Gu, Yongin-Si, Gyeonggi-Do, Korea
Tel: +82-31-679-9600 Fax: +82-31-336-1184 ERI-WI-ETRF001-06 Rev.No.2
5.4.3 Test instrument
Instrument Model No. Serial No. Makers Used Test receiver ESCS30 830986/015 R&S O
EMC ANALYZER E7405A US39430154 Agilent O
L.I.S.N. ESH3-Z5 827246/008 R&S - ESH3-Z6 825993/010 R&S -
Biconical Antenna VHA9103 91031951 Schwarzbeck - Log-Periodic Antenna UHALP9108A 0393 Schwarzbeck -
Bi-Log antenna VULB9165 2041 Schwarzbeck O Pre-Amp 8447D 2944A09757 Agilent -
Antenna Mast MA240 N/A HD O Turn Table DT430S N/A HD O
5.4.4 Test results
Date of test : 2007. 10. 24
Freq Reading Ant Pol.
AF CL Result Limit Margin (MHz) (dBµV) (dB/m) (dB) (dBµV/m) (dBµV/m) (dB) 175.50 10.7 V 10.75 2.18 23.6 30 6.40 185.20 10.2 H 10.29 2.23 22.7 30 7.28 379.20 5.5 H 14.62 3.22 23.3 37 13.70 403.50 3.5 H 15.03 3.32 21.8 37 15.20
* Results: Include Antenna Factor and cable loss * Margins : [Limits – Result Reading] * Receiving Antenna Mode: Horizontal, Vertical
Result: Pass The measured emissions level of the EUT have found the below of the specified limit.
EMC Research Institute File No. FCC07-00510628
Page 17 of 18
E R I, 66-6, Jeil-Ri, Yangji-Myun, Cheoin –Gu, Yongin-Si, Gyeonggi-Do, Korea
Tel: +82-31-679-9600 Fax: +82-31-336-1184 ERI-WI-ETRF001-06 Rev.No.2
MEASURMENT GRAPH
<Frequency rage: 30 MHz - 1 000 MHz, Antenna Polarity: Vertical>
<Frequency rage: 30 MHz - 1 000 MHz, Antenna Polarity: Horizontal>