Report No.: TR-W1811-015 ENG Co., Ltd. 135-60 Gyeongchung-daero, Gonjiam-eup, Gwangju-si, Gyeonggi-do, Korea 464-942 Report Form_01 (Rev.0) EMC DIRECTIVE 2014/30/EU VERIFICATION COMPLIANCE STATEMENT For the Product : 3D Printer Model : A1+ Multiple Model : A1 Applicant : Sindoh Co., Ltd. Standards : EN 55032, EN 55024, EN 301 489-1/-17 EN 61000-3-2, and EN 61000-3-3 We hereby certify that the above product has been tested by us with the listed standards and found in compliance with the EMC Directive. The test data and results are issued on the test report no. TR-W1811-015 Signature Choi, Young-min / Technical Manager Date: 2018-11-28 Test Laboratory: ENG Co., Ltd. It shall not be reproduced except in full, without the written approval of the ENG Co., Ltd. This document may be altered or revised by the ENG Co., Ltd. Personnel only, and shall be noted in the revision section of the document. The test results in the report only apply to the tested sample.

EMC DIRECTIVE 2014/30/EU

  • Upload
    others

  • View
    10

  • Download
    0

Embed Size (px)

Citation preview

Report No.: TR-W1811-015

ENG Co., Ltd. 135-60 Gyeongchung-daero, Gonjiam-eup, Gwangju-si, Gyeonggi-do, Korea 464-942 Report Form_01 (Rev.0)

EMC DIRECTIVE 2014/30/EU VERIFICATION COMPLIANCE STATEMENT

For the Product : 3D Printer

Model : A1+

Multiple Model : A1

Applicant : Sindoh Co., Ltd.

Standards

: EN 55032, EN 55024, EN 301 489-1/-17 EN 61000-3-2, and EN 61000-3-3

We hereby certify that the above product has been tested by us with the listed standards and found in compliance with the EMC Directive. The test data and results are issued on the test report no. TR-W1811-015

Signature

Choi, Young-min / Technical Manager

Date: 2018-11-28 Test Laboratory: ENG Co., Ltd.

It shall not be reproduced except in full, without the written approval of the ENG Co., Ltd. This document may be altered or revised by the ENG Co., Ltd. Personnel only, and shall be noted in the revision section of the document. The test results in the report only apply to the tested sample.

Report No.: TR-W1811-015 Page 1 of 101

ENG Co., Ltd. 135-60 Gyeongchung-daero, Gonjiam-eup, Gwangju-si, Gyeonggi-do, Korea 464-942 Report Form_01 (Rev.0)

TEL: +82-31-727-8300 FAX: +82-31-746-0800 http://www.the-eng.co.kr

CE EMC TEST REPORT

Project Number : EA1810C-142

Test Report Number : TR-W1811-015

Type of Equipment : 3D Printer

Model Name : A1+

Multiple Model Name : A1

Applicant : Sindoh Co., Ltd.

Address : 3, Seongsuiro24 (isipsa)-gil, Seongdong-gu,Seoul 04797, Republic of Korea

Manufacturer : Sindoh Co., Ltd.

Address : 3, Seongsuiro24 (isipsa)-gil, Seongdong-gu,Seoul 04797, Republic of Korea

Factory 1 : SINDOH (QINGDAO) CO., LTD.

Address : 1008 Emeisan-road, Qingdao Economics & Technology

Development Zone, 266555 Qingdao, Shandong, PEOPLE'S REPUBLIC OF CHINA

Factory 2 : Sindoh Co., Ltd.

Address : 1138, Suncheonhyang-ro, Baebang-eup, Asan-si,

Chungcheongnam-do 31479, REPUBLIC OF KOREA

Product Standard : EN 55032: 2012/AC: 2013, 55024:2010,

EN 301 489-1 V2.2.0 and EN 301 489-17 V3.2.0 EN 61000-3-2: 2014, and EN 61000-3-3: 2013

Total page of Report : 101 pages

Date of Receipt : 2018-10-31

Date of Issue : 2018-11-28

Test Result : PASS

This test report only contains the result of a single test of the sample supplied for the examination.

It is not a generally valid assessment of the features of the respective products of the mass-production.

Prepared by Chu, Woo-Sik / Senior Engineer 2018-11-28 Signature Date

Reviewed by Choi, Young-min / Technical Manager 2018-11-28 Signature Date

Report No.: TR-W1811-015 Page 2 of 101

ENG Co., Ltd. 135-60 Gyeongchung-daero, Gonjiam-eup, Gwangju-si, Gyeonggi-do, Korea 464-942 Report Form_01 (Rev.0)

TEL: +82-31-727-8300 FAX: +82-31-746-0800 http://www.the-eng.co.kr

CONTENTS Page

1. TEST SUMMARY .............................................................................................................................. 5

2. EUT (EQUIPMENT UNDER TEST) INFORMATION ......................................................................... 7

3. TEST CONDITION ........................................................................................................................... 10

4. EVALUATION DURING IMMUNITY TESTS ................................................................................... 13

5. MEASUREMENT UNCERTAINTY .................................................................................................. 15

6. EMISSION TESTS ........................................................................................................................... 16

6.1 MAIN TERMINAL CONTINUOUS DISTURBANCE VOLTAGE .................................................... 16

6.2 CONDUCTED COMMON MODE DISTURBANCE AT TELECOMMUNICATION PORTS ........... 35

6.3 RADIATED ELECTROMAGNETIC FIELD .................................................................................... 38

6.4 HARMONIC CURRENT EMISSIONS ............................................................................................ 57

6.5 VOLTAGE CHANGES, VOLTAGE FLUCTUATIONS AND FLICKER ......................................... 66

7. IMMUNITY TESTS ........................................................................................................................... 71

7.1 ELECTROSTATIC DISCHARGES IMMUNITY TEST ................................................................... 71

7.2 RF ELECTROMAGNETIC FIELD IMMUNITY TEST..................................................................... 74

7.3 ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST ...................................................... 76

7.4 SURGE IMMUNITY TEST ............................................................................................................. 78

7.5 RF CONTINUOUS CONDUCTED IMMUNITY TEST .................................................................... 80

7.6 POWER FREQUENCY MAGNETIC FIELD IMMUNITY TEST ..................................................... 81

7.7 VOLTAGE DIPS AND SHORT INTERRUPTIONS IMMUNITY TEST ........................................... 82

APPENDIX I - TEST SETUP PHOTO: MAIN TERMINAL CONTINUOUS DISTURBANCE

VOLTAGE TEST ................................................................................................................................. 84

APPENDIX II - TEST SETUP PHOTO: CONDUCTED COMMON MODE DISTURBANCE AT

TELECOMMUNICATION PORTS ....................................................................................................... 86

APPENDIX III - TEST SETUP PHOTO: RADIATED ELECTROMAGNETIC FIELD TEST ................ 87

APPENDIX IV – TEST SETUP PHOTO: HARMONIC CURRENTS & FLICKER TEST ..................... 91

APPENDIX V - TEST SETUP PHOTO: ELECTROSTATIC DISCHARGE TEST ............................... 92

Report No.: TR-W1811-015 Page 3 of 101

ENG Co., Ltd. 135-60 Gyeongchung-daero, Gonjiam-eup, Gwangju-si, Gyeonggi-do, Korea 464-942 Report Form_01 (Rev.0)

TEL: +82-31-727-8300 FAX: +82-31-746-0800 http://www.the-eng.co.kr

APPENDIX VI - TEST SETUP PHOTO: RADIO FREQUENCY ELECTROMAGNETIC FIELD TEST93

APPENDIX VII - TEST SETUP PHOTO: EFT/BURST TEST.............................................................. 95

APPENDIX VIII - TEST SETUP PHOTO: SURGE TEST .................................................................... 96

APPENDIX IX - TEST SETUP PHOTO: CONDUCTED RF FIELD TEST ........................................... 97

APPENDIX X - TEST SETUP PHOTO: POWER FREQUENCY MAGNETIC FIELD TEST ............... 98

APPENDIX XI - TEST SETUP PHOTO: VOLTAGE DIPS & INTERRUPTION TEST ........................ 99

APPENDIX XII - TEST INSTRUMENTATION ................................................................................... 100

Report No.: TR-W1811-015 Page 4 of 101

ENG Co., Ltd. 135-60 Gyeongchung-daero, Gonjiam-eup, Gwangju-si, Gyeonggi-do, Korea 464-942 Report Form_01 (Rev.0)

TEL: +82-31-727-8300 FAX: +82-31-746-0800 http://www.the-eng.co.kr

Release Control Record

Issue Report No. Issued Date Details/Revisions

TR-W1811-015 2018-11-28 Initial Release

Report No.: TR-W1811-015 Page 5 of 101

ENG Co., Ltd. 135-60 Gyeongchung-daero, Gonjiam-eup, Gwangju-si, Gyeonggi-do, Korea 464-942 Report Form_01 (Rev.0)

TEL: +82-31-727-8300 FAX: +82-31-746-0800 http://www.the-eng.co.kr

1. TEST SUMMARY

1.1 Test standards and results

The sample submitted for evaluation (hereafter refer to as the EUT) has been tested in accordance with the

following standards.

EMISSION

STANDARDS TEST NAME P F N.T. Note

EN 55032: 2012/

AC: 2013, Class A

EN 301 489-1/-17

Clause 7.1

Conducted emission on AC mains input port P Note 1

Conducted emission on telecommunication port P

Radiated emission P Note 2

EN 61000-3-2: 2014 Harmonic current emission P

EN 61000-3-3: 2013 Voltage changes, voltage fluctuations and flicker P

IMMUNITY

STANDARDS TEST NAME P F N.T. Note

EN 55024: 2010

EN 301 489-1/-17

Clause 7.2

Electrostatic Discharge P

RF Electromagnetic Field P

Electrical Fast Transient/Burst P

Surges P

RF Continuous Conducted P

Power-Frequency Magnetic Field P

Voltage Dips, Interruptions P

Remark:

P means Passed F means Failed N.T. means Not Tested

Note 1. The EUT does meet Class B Limits acc. to EN 301 489-1/-17

Note 2. This test is applicable for ancillary equipment acc. to the standard, EN 301 489-1/-17, but test was

performed for reporting purpose only.

1.2 Purpose of the test

To determine whether the equipment under test fulfills the EMC requirements of the standards stated in section

1.1 acc. to the applicant's requirement.

1.3 Additions, deviations, exclusions from standards

No additions, deviations or exclusions have been made from standard.

Report No.: TR-W1811-015 Page 6 of 101

ENG Co., Ltd. 135-60 Gyeongchung-daero, Gonjiam-eup, Gwangju-si, Gyeonggi-do, Korea 464-942 Report Form_01 (Rev.0)

TEL: +82-31-727-8300 FAX: +82-31-746-0800 http://www.the-eng.co.kr

1.4 Test Facility

The measurement facilities are located at 135-60 Gyeongchung-daero, Gonjiam-eup, Gwangju-si, Gyeonggi-do

12813, Korea. Description details of test facilities were submitted to the ISED, Canada, accredited as a

Conformity Assessment Body (CAB) by the FCC, designated by the RRA (Radio Research Agency), and

accredited by KOLAS (Korea Laboratory Accreditation Scheme) in Korea and approved by TUV Rheinland and

TUV SÜD according to the requirement of ISO 17025.

Laboratory Qualification Registration No. Mark

FCC KR0160

ISED (Canada) IC 12721A-1

RRA KR0160

TUV Rheinland UA 50314109-0002

TUV SÜD CARAT 18 03 94465 003

Korean Agency for Technology and

Standards KT733

Report No.: TR-W1811-015 Page 7 of 101

ENG Co., Ltd. 135-60 Gyeongchung-daero, Gonjiam-eup, Gwangju-si, Gyeonggi-do, Korea 464-942 Report Form_01 (Rev.0)

TEL: +82-31-727-8300 FAX: +82-31-746-0800 http://www.the-eng.co.kr

2. EUT (Equipment Under Test) INFORMATION

2.1 Photo of the EUT

Report No.: TR-W1811-015 Page 8 of 101

ENG Co., Ltd. 135-60 Gyeongchung-daero, Gonjiam-eup, Gwangju-si, Gyeonggi-do, Korea 464-942 Report Form_01 (Rev.0)

TEL: +82-31-727-8300 FAX: +82-31-746-0800 http://www.the-eng.co.kr

2.2 Equipment ID Label

Report No.: TR-W1811-015 Page 9 of 101

ENG Co., Ltd. 135-60 Gyeongchung-daero, Gonjiam-eup, Gwangju-si, Gyeonggi-do, Korea 464-942 Report Form_01 (Rev.0)

TEL: +82-31-727-8300 FAX: +82-31-746-0800 http://www.the-eng.co.kr

2.3 General Description The Sindoh Co., Ltd., Model A1+ (referred to as the EUT in this report) is a 3D Printer. The product specification described herein was obtained from product data sheet or user’s manual.

Printing Method SLA (Stereo Lithography Appratus)

Max. Print Length(mm) W(max):200, D(max):200, H(max):180

Layer Thickness Setting 0.025~0.100mm

Laser Wavelength 405nm

Laser Power 600mW

Resin Acrylic, ABS-Like

Temperature Management Fan Heater Type

Bed Leveling Manual, Semi-Auto

Resin Supply Air-Pump Type Automatic Supply with Level Sensor

Power 250W

Dimensions (mm) 449 x 501 x 600 (W x D x H)

Weight 44.3 Kg (excluding resin cartridge)

Ports USB Device, USB Host, Wifi, Ethernet

Contained RF Module

Model: TWFM-M311D

Manufacturer: LG Innotek Co., Ltd.

CE Marked acc. to Radio Equipment Directive, 2014/53/EU

2.4 Additional Model

Model Name Model Difference

A1+ Basic Model

A1 Identical to the basic model except for the model designation, optional parts, such as

Internal Camera, Playback, WiFi module and SSD.

Note: The manufacturer has declared to all the additional model names into basic model name without any

further evaluation by ENG Co., Ltd.

Report No.: TR-W1811-015 Page 10 of 101

ENG Co., Ltd. 135-60 Gyeongchung-daero, Gonjiam-eup, Gwangju-si, Gyeonggi-do, Korea 464-942 Report Form_01 (Rev.0)

TEL: +82-31-727-8300 FAX: +82-31-746-0800 http://www.the-eng.co.kr

3. TEST CONDITION

3.1 Equipment Used During Test

The following peripheral devices and/or interface cables were connected during the measurement:

Description Model No. Serial No. Manufacturer.

3D Printer (EUT) A1+ N/A Sindoh Co., Ltd.

Notebook PC TRN-C125 N/A HP

Adapter for Notebook PC HSTNN-CA40 N/A CHICONY Power Technology

Mouse M-U0026 N/A Logitech

Access Point (AP) AW-A1 ABRE400975NT Unicorn Information System

Adapter for AP K02-1201000 N/A Shenzhen KeYu Power Supply

Technology Co., Ltd.

USB Memory Stick 8GB-WJ004 N/A SHENZHEN CHENGE

ELECTRONICS CO., LTD.

3.2 Cable Description

Test

Mode Ports Name

Shielded

(Y/N)

Ferrite Bead

(Y/N)

Length

(m) Connected to

Mode #1 - #5

AC IN N N 1.8 AC Mains

LAN N N 3.0 Notebook PC

USB Y N 1.5

USB - - - USB Memory Stick

Mode #6 - #9

AC IN N N 1.8 AC Mains

LAN N N 3.0 Line terminated

USB Y N 1.5 Notebook PC

USB - - - USB Memory Stick

Report No.: TR-W1811-015 Page 11 of 101

ENG Co., Ltd. 135-60 Gyeongchung-daero, Gonjiam-eup, Gwangju-si, Gyeonggi-do, Korea 464-942 Report Form_01 (Rev.0)

TEL: +82-31-727-8300 FAX: +82-31-746-0800 http://www.the-eng.co.kr

USB Memory Stick

3.3 Mode of operation during the test

Test Mode Description

# 1 The EUT was operated in standby mode

# 2 Printing mode using USB cable between the EUT and a Notebook PC

# 3 Printing mode using USB memory stick

# 4 Printing mode using Ethernet speed, 100 Mbps

# 5 Printing mode using Ethernet speed, 1 000 Mbps

# 6 Printing mode using Wi-Fi function, 802.11b

# 7 Printing mode using Wi-Fi function, 802.11g

# 8 Printing mode using Wi-Fi function, 802.11n HT20

# 9 Printing mode using Wi-Fi function, 802.11n HT40

3.4 Test Setup Drawing

[Mode #1 ~ #5]

AC mains

A1+

(EUT)

Notebook PC

Adapter

Mouse

LAN Cable

USB Cable

Report No.: TR-W1811-015 Page 12 of 101

ENG Co., Ltd. 135-60 Gyeongchung-daero, Gonjiam-eup, Gwangju-si, Gyeonggi-do, Korea 464-942 Report Form_01 (Rev.0)

TEL: +82-31-727-8300 FAX: +82-31-746-0800 http://www.the-eng.co.kr

USB Memory Stick

[Mode #6 ~ #9]

3.5 EUT Modifications

- No EMC Relevant Modifications were performed by this test laboratory.

AC mains

A1+

(EUT)

Notebook PC

Adapter

Mouse

AP

Adapter

Line terminated -LAN

USB Cable

WiFi Communication

Report No.: TR-W1811-015 Page 13 of 101

ENG Co., Ltd. 135-60 Gyeongchung-daero, Gonjiam-eup, Gwangju-si, Gyeonggi-do, Korea 464-942 Report Form_01 (Rev.0)

TEL: +82-31-727-8300 FAX: +82-31-746-0800 http://www.the-eng.co.kr

4. Evaluation during Immunity Tests

4.1 Function Test

Verification of correct function was carried out before and after each immunity tests.

4.2 Criteria of acceptance

4.2.1 Performance Criteria of the standard, EN 55024

Criteria Description

A

The EUT shall continue to operate as intended without operator intervention. No degradation of

performance or loss of function is allowed below a performance level specified by the

manufacturer, when the EUT is used as intended. The performance level may be replaced by a

permissible loss of performance. If the minimum performance level or the permissible

performance loss is not specified by the manufacturer, then either of these may be derived from

the product description and documentation, and by what the user may reasonably expect from

the EUT if used as intended.

B

After test, the EUT shall continue to operate as intended without operator intervention. No

degradation of performance or loss of function is allowed after the application of the

phenomena below a performance level specified by the manufacturer, when the EUT is used as

intended. The performance level may be replaced by a permissible loss of performance. During

the test, degradation of performance is allowed. However, no change of actual operating state

or stored data is allowed to persist after test.

If the minimum performance level or the permissible performance loss is not specified by the

manufacturer, then either of these may be derived from the product description and

documentation, and by what the user may reasonably expect from the EUT if used as intended.

C

Loss of function is allowed, provided the function is self recoverable or can be restored by the

operation of the controls by the user in accordance with the manufacturer's instructions.

Functions, and/or information stored in non-volatile memory, or protected by a battery backup,

shall not be lost.

4.2.2 Particular Performance Criteria of the standard, EN 55024

Criteria Description

A The EUT shall maintain the specified printing quality and normal operation

B No degradation of the printing quality beyond the manufacturer's specification (such as

distortion of character(s) or mission pixels) is permissible.

C Printing errors or omission of character(s) which require reprinting are permissible. Input/output

failure which can be recovered to normal operation by reset or reboot are also permissible.

Report No.: TR-W1811-015 Page 14 of 101

ENG Co., Ltd. 135-60 Gyeongchung-daero, Gonjiam-eup, Gwangju-si, Gyeonggi-do, Korea 464-942 Report Form_01 (Rev.0)

TEL: +82-31-727-8300 FAX: +82-31-746-0800 http://www.the-eng.co.kr

4.2.3 Performance Criteria of the standard, EN 301 489-1/-17

Criteria Description

During test After test

A

Shall operate as intended. (see note 1).

Shall be no loss of function.

Shall be no unintentional transmissions

Shall operate as intended.

Shall be no degradation of performance (see note 3).

Shall be no loss of function.

Shall be no loss of stored data or user programmable

functions.

B

May show loss of function (one or

more).

May show degradation of performance

(see note 2).

Shall be no unintentional transmissions.

Functions shall be self-recoverable.

Shall operate as intended after recovering.

Shall be no degradation of performance (see note 3).

Shall be no loss of stored data or user programmable

functions.

C

May be loss of function (one or more). Functions shall be recoverable by the operator.

Shall operate as intended after recovering.

Shall be no degradation of performance (see note 3). NOTE 1: Operate as intended during the test allows a level of degradation not below a minimum performancelevel specified by the manufacturer for the use of the apparatus as intended. In some cases the specified minimum performance level may be replaced by a permissible degradation of performance. If the minimum performance level or the permissible performance degradation is not specified by the manufacturer then either of these may be derived from the product description and documentation (including leaflets and advertising) and what the user may reasonably expect from the apparatus if used as intended. NOTE 2: Degradation of performance during the test is understood as a degradation to a level not below a minimum performance level specified by the manufacturer for the use of the apparatus as intended. In some cases the specified minimum performance level may be replaced by a permissible degradation of performance. If the minimum performance level or the permissible performance degradation is not specified by the manufacturer then either of these may be derived from the product description and documentation (including leaflets and advertising) and what the user may reasonably expect from the apparatus if used as intended. NOTE 3: No degradation of performance after the test is understood as no degradation below a minimum performance level specified by the manufacturer for the use of the apparatus as intended. In some cases the specified minimum performance level may be replaced by a permissible degradation of performance. After the test no change of actual operating data or user retrievable data is allowed. If the minimum performance level or the permissible performance degradation is not specified by the manufacturer then either of these may be derived from the product description and documentation (including leaflets and advertising) and what the user may reasonably expect from the apparatus if used as intended.

Report No.: TR-W1811-015 Page 15 of 101

ENG Co., Ltd. 135-60 Gyeongchung-daero, Gonjiam-eup, Gwangju-si, Gyeonggi-do, Korea 464-942 Report Form_01 (Rev.0)

TEL: +82-31-727-8300 FAX: +82-31-746-0800 http://www.the-eng.co.kr

4.3 EUT Specific Performance Criteria

No specific performance criteria was provided by the manufacturer.

4.4 Functions Monitored During and After Immunity Test

Test Mode Description

# 1 Observed whether stand-by status was changed or not during the test.

# 2 ~ # 5 Observed whether printed object and operating status were changed or not during the test at

each mode.

# 6 ~ # 9 Observed whether printed object and operating status were changed or not and

communication link status was maintained during the test.

5. Measurement uncertainty

5.1 Emission:

Test Items Frequency range Uncertainty

Continuous Disturbance Voltage 150 kHz ~ 30 MHz 2.03 dB

Disturbance Power 30 MHz ~ 300 MHz 2.39 dB

Radiated electromagnetic field 30 MHz ~ 1 000 MHz 4.80 dB

1 000 MHz ~ 18 000 MHz 4.79 dB

Harmonic Current 50 Hz ~ 2 kHz 0.2 %

Voltage Fluctuation and Flicker N/A 5.0 %

The measurement uncertainties are given with at least 95 % confidence.

5.2 Immunity:

Test Items Frequency range Uncertainty

Electrostatic Discharge N/A Met the specified requirements in the standard

RF Electromagnetic Field 80 MHz ~ 3 GHz 1 V/m: 0.21 V/m, 3 V/m: 0.62 V/m,

10 V/m: 2.08 V/m

Electrical Fast Transient/Burst N/A Met the specified requirements in the standard

Surge N/A

Conducted RF Field 150 kHz ~ 80 MHz 1 V: 0.31 V, 3 V: 0.93 V, 10 V: 3.10 V

Power Frequency Magnetic Field N/A Met the specified requirements in the standard

Voltage dips and Short Interruptions N/A

The measurement uncertainties are given with at least 95 % confidence.

Report No.: TR-W1811-015 Page 16 of 101

ENG Co., Ltd. 135-60 Gyeongchung-daero, Gonjiam-eup, Gwangju-si, Gyeonggi-do, Korea 464-942 Report Form_01 (Rev.0)

TEL: +82-31-727-8300 FAX: +82-31-746-0800 http://www.the-eng.co.kr

6. EMISSION TESTS

6.1 MAIN TERMINAL CONTINUOUS DISTURBANCE VOLTAGE

6.1.1 Test setup

The EUT was placed on the floor as typical applications. Power was fed to the EUT through a 50 Ω /

50 μH + 5 Ω Artificial Mains Network (AMN). The ground plane was electrically bonded to the referenc

e ground system and all power lines were filtered from ambient.

The test set-up photos are included in appendix I.

Used Software for measurement is EMC 32 supplied by Rohde & Schwarz.

6.1.2 Test Result

Date of Test 2018-11-06 Temperature (17.0 ~ 21.2) °C

Test Mode Mode #1 ~ #9 Relative humidity (47.8 ~ 49.5) % R.H.

Frequency range 0.15 MHz ~ 30 MHz Resolution bandwidth 9 kHz

Test Result Pass Tested By Im, Jin-young

6.1.3 Sample Calculated Example

At 3.638 MHz CAV Limit = 60.0 dBµV

Correction Factor (C. Factor) of LISN, Pulse Limiter and cable loss at 3.638 MHz = 10.3 dB

CAV Reading from the Test receiver = 43.5 dBµV

(Calculated value for system losses by software EMC32 manufactured by Rohde & Schwarz)

Therefore CAV Margin = 60 - 43.5 = 16.5 so the EUT has 16.5 dB margin at 3.638 MHz

Report No.: TR-W1811-015 Page 17 of 101

ENG Co., Ltd. 135-60 Gyeongchung-daero, Gonjiam-eup, Gwangju-si, Gyeonggi-do, Korea 464-942 Report Form_01 (Rev.0)

TEL: +82-31-727-8300 FAX: +82-31-746-0800 http://www.the-eng.co.kr

6.1.4 Test data Mode #1 HOT LINE

Report No.: TR-W1811-015 Page 18 of 101

ENG Co., Ltd. 135-60 Gyeongchung-daero, Gonjiam-eup, Gwangju-si, Gyeonggi-do, Korea 464-942 Report Form_01 (Rev.0)

TEL: +82-31-727-8300 FAX: +82-31-746-0800 http://www.the-eng.co.kr

Mode #1 NEUTRAL LINE

Report No.: TR-W1811-015 Page 19 of 101

ENG Co., Ltd. 135-60 Gyeongchung-daero, Gonjiam-eup, Gwangju-si, Gyeonggi-do, Korea 464-942 Report Form_01 (Rev.0)

TEL: +82-31-727-8300 FAX: +82-31-746-0800 http://www.the-eng.co.kr

Mode #2 HOT LINE

Report No.: TR-W1811-015 Page 20 of 101

ENG Co., Ltd. 135-60 Gyeongchung-daero, Gonjiam-eup, Gwangju-si, Gyeonggi-do, Korea 464-942 Report Form_01 (Rev.0)

TEL: +82-31-727-8300 FAX: +82-31-746-0800 http://www.the-eng.co.kr

Mode #2 NEUTRAL LINE

Report No.: TR-W1811-015 Page 21 of 101

ENG Co., Ltd. 135-60 Gyeongchung-daero, Gonjiam-eup, Gwangju-si, Gyeonggi-do, Korea 464-942 Report Form_01 (Rev.0)

TEL: +82-31-727-8300 FAX: +82-31-746-0800 http://www.the-eng.co.kr

Mode #3 HOT LINE

Report No.: TR-W1811-015 Page 22 of 101

ENG Co., Ltd. 135-60 Gyeongchung-daero, Gonjiam-eup, Gwangju-si, Gyeonggi-do, Korea 464-942 Report Form_01 (Rev.0)

TEL: +82-31-727-8300 FAX: +82-31-746-0800 http://www.the-eng.co.kr

Mode #3 NEUTRAL LINE

Report No.: TR-W1811-015 Page 23 of 101

ENG Co., Ltd. 135-60 Gyeongchung-daero, Gonjiam-eup, Gwangju-si, Gyeonggi-do, Korea 464-942 Report Form_01 (Rev.0)

TEL: +82-31-727-8300 FAX: +82-31-746-0800 http://www.the-eng.co.kr

Mode #4 HOT LINE

Report No.: TR-W1811-015 Page 24 of 101

ENG Co., Ltd. 135-60 Gyeongchung-daero, Gonjiam-eup, Gwangju-si, Gyeonggi-do, Korea 464-942 Report Form_01 (Rev.0)

TEL: +82-31-727-8300 FAX: +82-31-746-0800 http://www.the-eng.co.kr

Mode #4 NEUTRAL LINE

Report No.: TR-W1811-015 Page 25 of 101

ENG Co., Ltd. 135-60 Gyeongchung-daero, Gonjiam-eup, Gwangju-si, Gyeonggi-do, Korea 464-942 Report Form_01 (Rev.0)

TEL: +82-31-727-8300 FAX: +82-31-746-0800 http://www.the-eng.co.kr

Mode #5 HOT LINE

Report No.: TR-W1811-015 Page 26 of 101

ENG Co., Ltd. 135-60 Gyeongchung-daero, Gonjiam-eup, Gwangju-si, Gyeonggi-do, Korea 464-942 Report Form_01 (Rev.0)

TEL: +82-31-727-8300 FAX: +82-31-746-0800 http://www.the-eng.co.kr

Mode #5 NEUTRAL LINE

Report No.: TR-W1811-015 Page 27 of 101

ENG Co., Ltd. 135-60 Gyeongchung-daero, Gonjiam-eup, Gwangju-si, Gyeonggi-do, Korea 464-942 Report Form_01 (Rev.0)

TEL: +82-31-727-8300 FAX: +82-31-746-0800 http://www.the-eng.co.kr

Mode #6 HOT LINE

Report No.: TR-W1811-015 Page 28 of 101

ENG Co., Ltd. 135-60 Gyeongchung-daero, Gonjiam-eup, Gwangju-si, Gyeonggi-do, Korea 464-942 Report Form_01 (Rev.0)

TEL: +82-31-727-8300 FAX: +82-31-746-0800 http://www.the-eng.co.kr

Mode #6 NEUTRAL LINE

Report No.: TR-W1811-015 Page 29 of 101

ENG Co., Ltd. 135-60 Gyeongchung-daero, Gonjiam-eup, Gwangju-si, Gyeonggi-do, Korea 464-942 Report Form_01 (Rev.0)

TEL: +82-31-727-8300 FAX: +82-31-746-0800 http://www.the-eng.co.kr

Mode #7 HOT LINE

Report No.: TR-W1811-015 Page 30 of 101

ENG Co., Ltd. 135-60 Gyeongchung-daero, Gonjiam-eup, Gwangju-si, Gyeonggi-do, Korea 464-942 Report Form_01 (Rev.0)

TEL: +82-31-727-8300 FAX: +82-31-746-0800 http://www.the-eng.co.kr

Mode #7 NEUTRAL LINE

Report No.: TR-W1811-015 Page 31 of 101

ENG Co., Ltd. 135-60 Gyeongchung-daero, Gonjiam-eup, Gwangju-si, Gyeonggi-do, Korea 464-942 Report Form_01 (Rev.0)

TEL: +82-31-727-8300 FAX: +82-31-746-0800 http://www.the-eng.co.kr

Mode #8 HOT LINE

Report No.: TR-W1811-015 Page 32 of 101

ENG Co., Ltd. 135-60 Gyeongchung-daero, Gonjiam-eup, Gwangju-si, Gyeonggi-do, Korea 464-942 Report Form_01 (Rev.0)

TEL: +82-31-727-8300 FAX: +82-31-746-0800 http://www.the-eng.co.kr

Mode #8 NEUTRAL LINE

Report No.: TR-W1811-015 Page 33 of 101

ENG Co., Ltd. 135-60 Gyeongchung-daero, Gonjiam-eup, Gwangju-si, Gyeonggi-do, Korea 464-942 Report Form_01 (Rev.0)

TEL: +82-31-727-8300 FAX: +82-31-746-0800 http://www.the-eng.co.kr

Mode #9 HOT LINE

Report No.: TR-W1811-015 Page 34 of 101

ENG Co., Ltd. 135-60 Gyeongchung-daero, Gonjiam-eup, Gwangju-si, Gyeonggi-do, Korea 464-942 Report Form_01 (Rev.0)

TEL: +82-31-727-8300 FAX: +82-31-746-0800 http://www.the-eng.co.kr

Mode #9 NEUTRAL LINE

Report No.: TR-W1811-015 Page 35 of 101

ENG Co., Ltd. 135-60 Gyeongchung-daero, Gonjiam-eup, Gwangju-si, Gyeonggi-do, Korea 464-942 Report Form_01 (Rev.0)

TEL: +82-31-727-8300 FAX: +82-31-746-0800 http://www.the-eng.co.kr

6.2 CONDUCTED COMMON MODE DISTURBANCE AT TELECOMMUNICATION PORTS

6.2.1 Test setup

The EUT was placed on the floor as typical applications. Power was fed to the EUT through a 50 Ω /

50 μH + 5 Ω Artificial Mains Network (AMN). Telecommunication line for the EUT connected to associat

e equipment through an Impedance Stabilization Network (ISN) which has a common mode termination

impedance of 150 ohms to the telecommunication port under test. The ground plane was electrically bo

nded to the reference ground system and all power lines were filtered from ambient.

The test set-up photos are included in appendix II.

Used Software for measurement is EMC 32 supplied by Rohde & Schwarz.

6.2.2 Test Result

Date of Test 2018-11-06 Temperature 21.2 °C

Test Mode Mode #4, and Mode #5 Relative humidity 49.5 % R.H.

Frequency range 0.15 MHz ~ 30 MHz Resolution bandwidth 9 kHz

Test Result Pass Tested By Im, Jin-young

6.2.3 Sample Calculated Example

At 1.794 MHz CAV Limit = 64.0 dBµV

Correction Factor (C. Factor) of LISN, Pulse Limiter and cable loss at 3.122 MHz = 9.3 dB

CAV Reading from the Test receiver = 25.3 dBµV

(Calculated value for system losses by software EMC32 manufactured by Rohde & Schwarz)

Therefore Q.P Margin = 64.0 – 25.3 = 38.7 so the EUT has 38.7 dB margin at 1.794 MHz

Report No.: TR-W1811-015 Page 36 of 101

ENG Co., Ltd. 135-60 Gyeongchung-daero, Gonjiam-eup, Gwangju-si, Gyeonggi-do, Korea 464-942 Report Form_01 (Rev.0)

TEL: +82-31-727-8300 FAX: +82-31-746-0800 http://www.the-eng.co.kr

6.2.4 Test data

Mode #4 CAT 5 (100 Mbps)

Report No.: TR-W1811-015 Page 37 of 101

ENG Co., Ltd. 135-60 Gyeongchung-daero, Gonjiam-eup, Gwangju-si, Gyeonggi-do, Korea 464-942 Report Form_01 (Rev.0)

TEL: +82-31-727-8300 FAX: +82-31-746-0800 http://www.the-eng.co.kr

Mode #5 CAT 6 (1 000 Mbps)

Report No.: TR-W1811-015 Page 38 of 101

ENG Co., Ltd. 135-60 Gyeongchung-daero, Gonjiam-eup, Gwangju-si, Gyeonggi-do, Korea 464-942 Report Form_01 (Rev.0)

TEL: +82-31-727-8300 FAX: +82-31-746-0800 http://www.the-eng.co.kr

6.3 RADIATED ELECTROMAGNETIC FIELD

6.3.1 Test setup

The radiated emissions measurements were on the 10 m, semi anechoic chamber. The EUT and all local

support equipments were placed on a non-conductive turntable approximately 0.1 m above the ground plane.

The frequency spectrum from 30 MHz to 1 000 MHz was scanned and emission levels maximized at each

frequency recorded. The system was rotated 360°, and the antenna was varied in height between 1.0 m and

4.0 m in order to determine the maximum emission levels. This procedure was performed for both horizontal

and vertical polarization of the receiving antenna.

The test set-up photos are included in appendix III.

Used Software for measurement is manufactured by TSJ.

6.3.2 Test result

Date of Test 2018-11-05 Test Mode Mode #1 ~ #9

Temperature (17.4 ~ 20.8) °C Relative humidity (46.5 ~ 51.2) %R.H.

Frequency range 30 MHz ~ 1 000 MHz Resolution bandwidth 120 kHz

Measurement distance 10 m Test Result Pass

Temperature (21.0 ~ 22.3) °C Relative humidity (47.2 ~ 50.8) %R.H.

Frequency range 1 000 MHz ~ 6 000 MHz Resolution bandwidth 1 MHz

Test Result Pass Tested By Im, Jin-young

6.3.3 Sample Calculated Example

At 120.210 MHz Limit = 40.0 dBµV/m

Result =Receiver reading value + Antenna Factor + Cable Loss - Pre-amplifier gain = 32.7 dBµV/m

Margin = Limit - Result =40.0 – 32.7 = 7.3 so the EUT has 7.3 dB margin at 120.210 MHz

Report No.: TR-W1811-015 Page 39 of 101

ENG Co., Ltd. 135-60 Gyeongchung-daero, Gonjiam-eup, Gwangju-si, Gyeonggi-do, Korea 464-942 Report Form_01 (Rev.0)

TEL: +82-31-727-8300 FAX: +82-31-746-0800 http://www.the-eng.co.kr

6.3.4 Test data

Mode #1 Frequency range_30 MHz ~ 1 000 MHz

NOTE: Quasi-Peak was not measured, because Peak values met Quasi-Peak limit.

Report No.: TR-W1811-015 Page 40 of 101

ENG Co., Ltd. 135-60 Gyeongchung-daero, Gonjiam-eup, Gwangju-si, Gyeonggi-do, Korea 464-942 Report Form_01 (Rev.0)

TEL: +82-31-727-8300 FAX: +82-31-746-0800 http://www.the-eng.co.kr

Mode #1 Frequency range_1 000 MHz ~ 6 000 MHz [Peak Data]

NOTE: Average mode was not measured, because Peak values were under the Average limit.

Report No.: TR-W1811-015 Page 41 of 101

ENG Co., Ltd. 135-60 Gyeongchung-daero, Gonjiam-eup, Gwangju-si, Gyeonggi-do, Korea 464-942 Report Form_01 (Rev.0)

TEL: +82-31-727-8300 FAX: +82-31-746-0800 http://www.the-eng.co.kr

Mode #2 Frequency range_30 MHz ~ 1 000 MHz

Report No.: TR-W1811-015 Page 42 of 101

ENG Co., Ltd. 135-60 Gyeongchung-daero, Gonjiam-eup, Gwangju-si, Gyeonggi-do, Korea 464-942 Report Form_01 (Rev.0)

TEL: +82-31-727-8300 FAX: +82-31-746-0800 http://www.the-eng.co.kr

Mode #2 Frequency range_1 000 MHz ~ 6 000 MHz [Peak Data]

NOTE: Average mode was not measured, because Peak values were under the Average limit.

Report No.: TR-W1811-015 Page 43 of 101

ENG Co., Ltd. 135-60 Gyeongchung-daero, Gonjiam-eup, Gwangju-si, Gyeonggi-do, Korea 464-942 Report Form_01 (Rev.0)

TEL: +82-31-727-8300 FAX: +82-31-746-0800 http://www.the-eng.co.kr

Mode #3 Frequency range_30 MHz ~ 1 000 MHz

Report No.: TR-W1811-015 Page 44 of 101

ENG Co., Ltd. 135-60 Gyeongchung-daero, Gonjiam-eup, Gwangju-si, Gyeonggi-do, Korea 464-942 Report Form_01 (Rev.0)

TEL: +82-31-727-8300 FAX: +82-31-746-0800 http://www.the-eng.co.kr

Mode #3 Frequency range_1 000 MHz ~ 6 000 MHz [Peak Data]

NOTE: Average mode was not measured, because Peak values were under the Average limit.

Report No.: TR-W1811-015 Page 45 of 101

ENG Co., Ltd. 135-60 Gyeongchung-daero, Gonjiam-eup, Gwangju-si, Gyeonggi-do, Korea 464-942 Report Form_01 (Rev.0)

TEL: +82-31-727-8300 FAX: +82-31-746-0800 http://www.the-eng.co.kr

Mode #4 Frequency range_30 MHz ~ 1 000 MHz

Report No.: TR-W1811-015 Page 46 of 101

ENG Co., Ltd. 135-60 Gyeongchung-daero, Gonjiam-eup, Gwangju-si, Gyeonggi-do, Korea 464-942 Report Form_01 (Rev.0)

TEL: +82-31-727-8300 FAX: +82-31-746-0800 http://www.the-eng.co.kr

Mode #4 Frequency range_1 000 MHz ~ 6 000 MHz [Peak Data]

NOTE: Average mode was not measured, because Peak values were under the Average limit.

Report No.: TR-W1811-015 Page 47 of 101

ENG Co., Ltd. 135-60 Gyeongchung-daero, Gonjiam-eup, Gwangju-si, Gyeonggi-do, Korea 464-942 Report Form_01 (Rev.0)

TEL: +82-31-727-8300 FAX: +82-31-746-0800 http://www.the-eng.co.kr

Mode #5 Frequency range_30 MHz ~ 1 000 MHz

Report No.: TR-W1811-015 Page 48 of 101

ENG Co., Ltd. 135-60 Gyeongchung-daero, Gonjiam-eup, Gwangju-si, Gyeonggi-do, Korea 464-942 Report Form_01 (Rev.0)

TEL: +82-31-727-8300 FAX: +82-31-746-0800 http://www.the-eng.co.kr

Mode #5 Frequency range_1 000 MHz ~ 6 000 MHz [Peak Data]

NOTE: Average mode was not measured, because Peak values were under the Average limit.

Report No.: TR-W1811-015 Page 49 of 101

ENG Co., Ltd. 135-60 Gyeongchung-daero, Gonjiam-eup, Gwangju-si, Gyeonggi-do, Korea 464-942 Report Form_01 (Rev.0)

TEL: +82-31-727-8300 FAX: +82-31-746-0800 http://www.the-eng.co.kr

Mode #6 Frequency range_30 MHz ~ 1 000 MHz

Note: This test result is for reporting purpose only.

Report No.: TR-W1811-015 Page 50 of 101

ENG Co., Ltd. 135-60 Gyeongchung-daero, Gonjiam-eup, Gwangju-si, Gyeonggi-do, Korea 464-942 Report Form_01 (Rev.0)

TEL: +82-31-727-8300 FAX: +82-31-746-0800 http://www.the-eng.co.kr

Mode #6 Frequency range_1 000 MHz ~ 6 000 MHz [Peak Data]

NOTE: Average mode was not measured, because Peak values were under the Average limit.

WiFi Carrier Frequency

Report No.: TR-W1811-015 Page 51 of 101

ENG Co., Ltd. 135-60 Gyeongchung-daero, Gonjiam-eup, Gwangju-si, Gyeonggi-do, Korea 464-942 Report Form_01 (Rev.0)

TEL: +82-31-727-8300 FAX: +82-31-746-0800 http://www.the-eng.co.kr

Mode #7 Frequency range_30 MHz ~ 1 000 MHz

Note: This test result is for reporting purpose only.

Report No.: TR-W1811-015 Page 52 of 101

ENG Co., Ltd. 135-60 Gyeongchung-daero, Gonjiam-eup, Gwangju-si, Gyeonggi-do, Korea 464-942 Report Form_01 (Rev.0)

TEL: +82-31-727-8300 FAX: +82-31-746-0800 http://www.the-eng.co.kr

Mode #7 Frequency range_1 000 MHz ~ 6 000 MHz [Peak Data]

NOTE: Average mode was not measured, because Peak values were under the Average limit.

WiFi Carrier Frequency

Report No.: TR-W1811-015 Page 53 of 101

ENG Co., Ltd. 135-60 Gyeongchung-daero, Gonjiam-eup, Gwangju-si, Gyeonggi-do, Korea 464-942 Report Form_01 (Rev.0)

TEL: +82-31-727-8300 FAX: +82-31-746-0800 http://www.the-eng.co.kr

Mode #8 Frequency range_30 MHz ~ 1 000 MHz

Note: This test result is for reporting purpose only.

Report No.: TR-W1811-015 Page 54 of 101

ENG Co., Ltd. 135-60 Gyeongchung-daero, Gonjiam-eup, Gwangju-si, Gyeonggi-do, Korea 464-942 Report Form_01 (Rev.0)

TEL: +82-31-727-8300 FAX: +82-31-746-0800 http://www.the-eng.co.kr

Mode #8 Frequency range_1 000 MHz ~ 6 000 MHz [Peak Data]

NOTE: Average mode was not measured, because Peak values were under the Average limit.

WiFi Carrier Frequency

Report No.: TR-W1811-015 Page 55 of 101

ENG Co., Ltd. 135-60 Gyeongchung-daero, Gonjiam-eup, Gwangju-si, Gyeonggi-do, Korea 464-942 Report Form_01 (Rev.0)

TEL: +82-31-727-8300 FAX: +82-31-746-0800 http://www.the-eng.co.kr

Mode #9 Frequency range_30 MHz ~ 1 000 MHz

Note: This test result is for reporting purpose only.

Report No.: TR-W1811-015 Page 56 of 101

ENG Co., Ltd. 135-60 Gyeongchung-daero, Gonjiam-eup, Gwangju-si, Gyeonggi-do, Korea 464-942 Report Form_01 (Rev.0)

TEL: +82-31-727-8300 FAX: +82-31-746-0800 http://www.the-eng.co.kr

Mode #9 Frequency range_1 000 MHz ~ 6 000 MHz [Peak Data]

NOTE: Average mode was not measured, because Peak values were under the Average limit.

WiFi Carrier Frequency

Report No.: TR-W1811-015 Page 57 of 101

ENG Co., Ltd. 135-60 Gyeongchung-daero, Gonjiam-eup, Gwangju-si, Gyeonggi-do, Korea 464-942 Report Form_01 (Rev.0)

TEL: +82-31-727-8300 FAX: +82-31-746-0800 http://www.the-eng.co.kr

6.4 HARMONIC CURRENT EMISSIONS

6.4.1 Test setup

Harmonics of the fundamental current were measured up to 2 kHz using a universal power analyzer. The

measurements were carried out under steady conditions and using average.

Before making measurements, it is necessary for the EUT to decide which class the EUT fulfills into; A, B, C or

D.

The test set-up photo is included in appendix IV.

6.4.2 Test result

Date of Test 2018-11-12 Temperature 18.4 °C

Test Mode Mode #5, #9 Relative humidity 51.3 % R.H.

Test Result Pass Tested By Im, Jin-young

Note: See next page for Harmonic Current on AC mains test data.

Report No.: TR-W1811-015 Page 58 of 101

ENG Co., Ltd. 135-60 Gyeongchung-daero, Gonjiam-eup, Gwangju-si, Gyeonggi-do, Korea 464-942 Report Form_01 (Rev.0)

TEL: +82-31-727-8300 FAX: +82-31-746-0800 http://www.the-eng.co.kr

6.4.3 Test data

6.4.3.1 Test mode: Mode #5

Report No.: TR-W1811-015 Page 59 of 101

ENG Co., Ltd. 135-60 Gyeongchung-daero, Gonjiam-eup, Gwangju-si, Gyeonggi-do, Korea 464-942 Report Form_01 (Rev.0)

TEL: +82-31-727-8300 FAX: +82-31-746-0800 http://www.the-eng.co.kr

Report No.: TR-W1811-015 Page 60 of 101

ENG Co., Ltd. 135-60 Gyeongchung-daero, Gonjiam-eup, Gwangju-si, Gyeonggi-do, Korea 464-942 Report Form_01 (Rev.0)

TEL: +82-31-727-8300 FAX: +82-31-746-0800 http://www.the-eng.co.kr

Report No.: TR-W1811-015 Page 61 of 101

ENG Co., Ltd. 135-60 Gyeongchung-daero, Gonjiam-eup, Gwangju-si, Gyeonggi-do, Korea 464-942 Report Form_01 (Rev.0)

TEL: +82-31-727-8300 FAX: +82-31-746-0800 http://www.the-eng.co.kr

Report No.: TR-W1811-015 Page 62 of 101

ENG Co., Ltd. 135-60 Gyeongchung-daero, Gonjiam-eup, Gwangju-si, Gyeonggi-do, Korea 464-942 Report Form_01 (Rev.0)

TEL: +82-31-727-8300 FAX: +82-31-746-0800 http://www.the-eng.co.kr

6.4.3.2 Test mode: Mode #9

Report No.: TR-W1811-015 Page 63 of 101

ENG Co., Ltd. 135-60 Gyeongchung-daero, Gonjiam-eup, Gwangju-si, Gyeonggi-do, Korea 464-942 Report Form_01 (Rev.0)

TEL: +82-31-727-8300 FAX: +82-31-746-0800 http://www.the-eng.co.kr

Report No.: TR-W1811-015 Page 64 of 101

ENG Co., Ltd. 135-60 Gyeongchung-daero, Gonjiam-eup, Gwangju-si, Gyeonggi-do, Korea 464-942 Report Form_01 (Rev.0)

TEL: +82-31-727-8300 FAX: +82-31-746-0800 http://www.the-eng.co.kr

Report No.: TR-W1811-015 Page 65 of 101

ENG Co., Ltd. 135-60 Gyeongchung-daero, Gonjiam-eup, Gwangju-si, Gyeonggi-do, Korea 464-942 Report Form_01 (Rev.0)

TEL: +82-31-727-8300 FAX: +82-31-746-0800 http://www.the-eng.co.kr

Report No.: TR-W1811-015 Page 66 of 101

ENG Co., Ltd. 135-60 Gyeongchung-daero, Gonjiam-eup, Gwangju-si, Gyeonggi-do, Korea 464-942 Report Form_01 (Rev.0)

TEL: +82-31-727-8300 FAX: +82-31-746-0800 http://www.the-eng.co.kr

6.5 VOLTAGE CHANGES, VOLTAGE FLUCTUATIONS AND FLICKER

6.5.1 Test setup

The voltage changes at the supply terminals were measured across the complex reference impedance Z = (0.4

+ j0.25) Ω.

The short-term flicker values are measured during a time interval of 10 min. Dc = relative voltage change

between two steady states and Dmax = maximum single voltage change, are measured over the reference

impedance. Long-term flicker values were measured during 120 minutes.

The test set-up photo is included in appendix IV.

6.5.2 Test result

6.5.2.1 Test mode: Mode #5

Date of Test 2018-11-12 Temperature 18.4 °C

Test Mode Mode #5 Relative humidity 51.3 % R.H.

Test Result Pass Tested By Im, Jin-young

Report No.: TR-W1811-015 Page 67 of 101

ENG Co., Ltd. 135-60 Gyeongchung-daero, Gonjiam-eup, Gwangju-si, Gyeonggi-do, Korea 464-942 Report Form_01 (Rev.0)

TEL: +82-31-727-8300 FAX: +82-31-746-0800 http://www.the-eng.co.kr

6.5.2.2 Test mode: Mode #9

Date of Test 2018-11-12 Temperature 18.4 °C

Test Mode Mode #9 Relative humidity 51.3 % R.H.

Test Result Pass Tested By Im, Jin-young

Report No.: TR-W1811-015 Page 68 of 101

ENG Co., Ltd. 135-60 Gyeongchung-daero, Gonjiam-eup, Gwangju-si, Gyeonggi-do, Korea 464-942 Report Form_01 (Rev.0)

TEL: +82-31-727-8300 FAX: +82-31-746-0800 http://www.the-eng.co.kr

6.5.2.3 Test mode: Mode #1, Standby mode

Date of Test 2018-11-12 Temperature 18.4 °C

Test Mode Mode #1 Relative humidity 51.3 % R.H.

Test Result Pass Tested By Im, Jin-young

Report No.: TR-W1811-015 Page 69 of 101

ENG Co., Ltd. 135-60 Gyeongchung-daero, Gonjiam-eup, Gwangju-si, Gyeonggi-do, Korea 464-942 Report Form_01 (Rev.0)

TEL: +82-31-727-8300 FAX: +82-31-746-0800 http://www.the-eng.co.kr

Report No.: TR-W1811-015 Page 70 of 101

ENG Co., Ltd. 135-60 Gyeongchung-daero, Gonjiam-eup, Gwangju-si, Gyeonggi-do, Korea 464-942 Report Form_01 (Rev.0)

TEL: +82-31-727-8300 FAX: +82-31-746-0800 http://www.the-eng.co.kr

Report No.: TR-W1811-015 Page 71 of 101

ENG Co., Ltd. 135-60 Gyeongchung-daero, Gonjiam-eup, Gwangju-si, Gyeonggi-do, Korea 464-942 Report Form_01 (Rev.0)

TEL: +82-31-727-8300 FAX: +82-31-746-0800 http://www.the-eng.co.kr

7. IMMUNITY TESTS

7.1 ELECTROSTATIC DISCHARGES IMMUNITY TEST

7.1.1 Test specification

Discharge Voltage Air Discharge: 2, 4, 8 kV Contact Discharge: 4 kV

Polarity Positive / Negative

Number of Discharge

Max. repetition rate

Minimum 10 single air discharge at a point

Minimum 25 single contact discharge at a point

One discharge per second

EUT-position Table top

7.1.2 Test setup

The EUT and all local support equipment were placed on non-metallic support 0.8 m above a reference

ground plane (RGP) and the minimum distance between the EUT and any laboratory walls or any oth

er metallic surfaces shall be at least 1 meter and were put into operation according to the specified op

erating mode.

Air discharges were applied to non-metallic parts of the EUT and Contact discharges were applied to al

l accessible metallic parts. Discharges were also applied to the Vertical Coupling Plane, where applicabl

e. The test set-up photos are included in appendix V.

7.1.3 Test result

Date of Test 2018-11-15 Temperature 16.8 °C

Test Location Shielded Room Relative humidity 51.4 % R.H.

Test Mode Mode #1 ~ #9 Atmospheric pressure 100.4 kPa

Required Criteria B Test Result PASS

Tested By Im, Jin-young

Report No.: TR-W1811-015 Page 72 of 101

ENG Co., Ltd. 135-60 Gyeongchung-daero, Gonjiam-eup, Gwangju-si, Gyeonggi-do, Korea 464-942 Report Form_01 (Rev.0)

TEL: +82-31-727-8300 FAX: +82-31-746-0800 http://www.the-eng.co.kr

Test Data For Mode #1 ~ Mode #9

Discharge

Level (± kV) ESD Points

No. of

DischargeResult Description

4 (Contact) (1) Enclosure (Metal Part),

Screws 25/Pol. A There was no deviation from normal

operating condition. 2/4/8 (Air) (2) Enclosure (Plastic Part) 10/Pol. A

4 (Contact) (3) USB Port

(Front, Back side) 25/Pol. B

The text on display panel was flickered,

but return to normal operation after

completing the test.

4 (Contact) (4) LAN Port 25/Pol. A There was no deviation from normal

operating condition. 2/4/8 (Air) (5) AC IN Port 10/Pol. A

2/4/8 (Air) (6) Display Panel,

Power Button Switch 10/Pol B

The text on display panel was flickered,

but return to normal operation after

completing the test.

4 (Indirect) HCP/VCP 25/Pol. A There was no deviation from normal

operating condition.

Note. The test points of the EUT are each location on the surface touchable by hand (see test point in next

page)

Report No.: TR-W1811-015 Page 73 of 101

ENG Co., Ltd. 135-60 Gyeongchung-daero, Gonjiam-eup, Gwangju-si, Gyeonggi-do, Korea 464-942 Report Form_01 (Rev.0)

TEL: +82-31-727-8300 FAX: +82-31-746-0800 http://www.the-eng.co.kr

7.1.4 Test Points

Air-Direct

Contact-Direct

2

3

1

3

6

5

4

1

1

Report No.: TR-W1811-015 Page 74 of 101

ENG Co., Ltd. 135-60 Gyeongchung-daero, Gonjiam-eup, Gwangju-si, Gyeonggi-do, Korea 464-942 Report Form_01 (Rev.0)

TEL: +82-31-727-8300 FAX: +82-31-746-0800 http://www.the-eng.co.kr

7.2 RF ELECTROMAGNETIC FIELD IMMUNITY TEST

7.2.1 Test specification

Frequency range & Test Level (80 ~ 6 000) MHz (3 V/m)

Modulation AM 80 %, 1 kHz

Frequency step 1 %

Dwell time at each frequency 3 s

Exposed side Front / Back / Left / Right

Polarization of antenna Horizontal / Vertical

EUT-position Table top

Distance of antenna – EUT 3 m

7.2.2 Test setup

The EUT and all local support equipment were placed on a non-metallic support 0.8 m above a referen

ce ground plane (RGP) in a fully anechoic chamber and were put into operation according to the specif

ied operating mode. The test set-up photos are included in appendix VI.

7.2.3 Test result

Date of Test 2018-11-08 ~ 11-13 Temperature (16.6 ~ 20.8) °C

Test Location Anechoic Chamber Relative humidity (48.6 ~ 51.9) % R.H.

Test Mode Mode #1 ~ #9 Atmospheric pressure (100.8 ~ 100.9) kPa

Required Criteria A Test Result PASS

Tested By Im, Jin-young

Report No.: TR-W1811-015 Page 75 of 101

ENG Co., Ltd. 135-60 Gyeongchung-daero, Gonjiam-eup, Gwangju-si, Gyeonggi-do, Korea 464-942 Report Form_01 (Rev.0)

TEL: +82-31-727-8300 FAX: +82-31-746-0800 http://www.the-eng.co.kr

Test Data For Mode #1 ~ #5 acc. to EN 55 024

Freq. Range [MHz] Pol.

V/H Exposed side Result Description

80 ~ 1 000

V/H Front A

There was no deviation from normal

operating condition.

V/H Back A

V/H Left A

V/H Right A

Test Data For Mode #6 ~ #9 acc. to EN 301 489-1/-17

Freq. Range [MHz] Pol.

V/H Exposed side Result Description

80 ~ 6 000

V/H Front A

There was no deviation from normal

operating condition.

V/H Back A

V/H Left A

V/H Right A

*Note: The exclusion band (: 2 280 MHz ~ 2 607.675 MHz) was applied during the test.

Report No.: TR-W1811-015 Page 76 of 101

ENG Co., Ltd. 135-60 Gyeongchung-daero, Gonjiam-eup, Gwangju-si, Gyeonggi-do, Korea 464-942 Report Form_01 (Rev.0)

TEL: +82-31-727-8300 FAX: +82-31-746-0800 http://www.the-eng.co.kr

7.3 ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST

7.3.1 Test specification

Test level 1 kV (AC Input), 0.5 kV(Signal line)

Burst frequency 5 kHz

Polarity Positive / Negative

Coupling time 60 s

Coupling methods

AC/DC mains – Coupling Decoupling Network (CDN)

Signal lines–Capacitive Coupling Clamp(CCC)

Lines for test AC mains of the EUT

Type of line Unshielded, AC/DC Adapter input line

EUT-position Table top

7.3.2 Test setup

The EUT and all cables to the EUT were placed on non-metallic support 0.1 m above a reference grou

nd plane (RGP) and were put into operation according to the specified operating mode.

The minimum distance between the EUT and all other conductive structures (e.g. the walls of a shielde

d room), except the ground reference plane shall be more than 0.5 m. Unless otherwise specified in th

e product standard or the product family standard, the length of the signal and power lines between th

e coupling device and the EUT shall be 0.5 m ± 0.05 m. If the manufacturer provides a non-detachabl

e supply cable more than 0.5 m ± 0.05 m long with the equipment, the excess length of this cable sh

all be folded to avoid a flat coil and situated at a distance of 0.1 m above the ground reference plane.

The test set-up photos are included in appendix VII.

Report No.: TR-W1811-015 Page 77 of 101

ENG Co., Ltd. 135-60 Gyeongchung-daero, Gonjiam-eup, Gwangju-si, Gyeonggi-do, Korea 464-942 Report Form_01 (Rev.0)

TEL: +82-31-727-8300 FAX: +82-31-746-0800 http://www.the-eng.co.kr

7.3.3 Test result

Date of Test 2018-11-16 Temperature 19.2 °C

Test Location Shielded Room Relative humidity 49.9 % R.H.

Test Mode Mode #1 ~ #9 Atmospheric pressure 100.6 kPa

Required Criteria B Test Result PASS

Tested By Im, Jin-young

Test Data

Line for test Coupling Method

Test level[± kV]

Result Description

AC-mains

L CDN 1 A

There was no deviation from

normal operating condition.

N CDN 1 A

PE CDN 1 A

L+N CDN 1 A

L+PE CDN 1 A

N+PE CDN 1 A

L+N+PE CDN 1 A

Signal lines LAN Cable CCC 0.5 A There was no deviation from

normal operating condition.

Report No.: TR-W1811-015 Page 78 of 101

ENG Co., Ltd. 135-60 Gyeongchung-daero, Gonjiam-eup, Gwangju-si, Gyeonggi-do, Korea 464-942 Report Form_01 (Rev.0)

TEL: +82-31-727-8300 FAX: +82-31-746-0800 http://www.the-eng.co.kr

7.4 SURGE IMMUNITY TEST

7.4.1 Test specification

Test level 0.5 kV, 1 kV (Line-to-Line),

0.5 kV, 1 kV , 2 kV (Lint-to-Ground)

Number of surge 5 surges / polarity

Polarity Positive / Negative

Angle 0° / 90° / 180° / 270°

Repetition rate 60 s

Coupling methods

AC mains – Coupling Decoupling Network (CDN)

DC-Input port – Coupling/Decoupling Network (CDN)

Lines for test AC mains of the EUT

Type of line Unshielded, AC/DC Adapter input line

EUT-position Table top

7.4.2 Test setup

The EUT and all local support equipment were placed on a non-metallic support 0.8 m above a referen

ce ground plane (RGP) and were put into operation according to the specified operating mode.

The test set-up photos are included in appendix VIII.

7.4.3 Test result

Date of Test 2018-11-13 ~ 11-14 Temperature (18.3 ~ 21.3) °C

Test Location Shielded Room Relative humidity (47.5 ~ 50.2) % R.H.

Test Mode Mode #1 ~ #9 Atmospheric pressure (100.2 ~ 100.4) kPa

Required Criteria B Test Result PASS

Tested By Im, Jin-young

Report No.: TR-W1811-015 Page 79 of 101

ENG Co., Ltd. 135-60 Gyeongchung-daero, Gonjiam-eup, Gwangju-si, Gyeonggi-do, Korea 464-942 Report Form_01 (Rev.0)

TEL: +82-31-727-8300 FAX: +82-31-746-0800 http://www.the-eng.co.kr

Test Data

Line for test Coupling Method

Test level[± kV]

Result Description

AC-mains

L+ N CDN 0.5 A There was no deviation from normal

operating condition. 1 A

L + PE CDN

0.5 A There was no deviation from normal

operating condition. 1 A

2 A

N + PE CDN

0.5 A There was no deviation from normal

operating condition. 1 A

2 A

Report No.: TR-W1811-015 Page 80 of 101

ENG Co., Ltd. 135-60 Gyeongchung-daero, Gonjiam-eup, Gwangju-si, Gyeonggi-do, Korea 464-942 Report Form_01 (Rev.0)

TEL: +82-31-727-8300 FAX: +82-31-746-0800 http://www.the-eng.co.kr

7.5 RF CONTINUOUS CONDUCTED IMMUNITY TEST

7.5.1 Test specification

Test level 3 V (AM 80 %, 1 kHz)

Frequency range 0.15 MHz ~ 80 MHz

Frequency step 1 %

Dwell time at each frequency 3 s

Coupling methods AC input– CDN

Signal line–EM clamp

Lines for test AC mains of the EUT

Signal lines of the EUT

Type of line Unshielded

EUT-position Table top

7.5.2 Test setup

The EUT and all local support equipment were placed on a non-metallic support 0.1 m above a referen

ce ground plane (RGP) and were put into operation according to the specified operating mode.

The test set-up photos are included in appendix IX.

7.5.3 Test result

Date of Test 2018-11-14 ~ 11-15 Temperature (19.4 ~ 21.7) °C

Test Location Shielded Room Relative humidity (47.9 ~ 51.1) % R.H.

Test Mode Mode #1 ~ #9 Atmospheric pressure (100.5 ~ 100.7) kPa

Required Criteria A Test Result PASS

Tested By Im, Jin-young

Test Data

Line for Test Coupling Method

Result Description

AC-mains CDN A There was no deviation from normal operating

condition Signal lines LAN Cable EM Clamp A

Report No.: TR-W1811-015 Page 81 of 101

ENG Co., Ltd. 135-60 Gyeongchung-daero, Gonjiam-eup, Gwangju-si, Gyeonggi-do, Korea 464-942 Report Form_01 (Rev.0)

TEL: +82-31-727-8300 FAX: +82-31-746-0800 http://www.the-eng.co.kr

7.6 POWER FREQUENCY MAGNETIC FIELD IMMUNITY TEST

7.6.1 Test specification

Test level 1 A/m

Frequency range 50 Hz

Duration 120 s

Axis of Orientation X/Y/Z axis

EUT-position Table top

7.6.2 Test setup

The EUT and all local support equipment were placed on a non-metallic support 0.1 m above a referen

ce ground plane (RGP) and were put into operation according to the specified operating mode.

The test set-up photo is included in appendix X.

7.6.3 Test result

Date of Test 2018-11-15 Temperature 21.0 °C

Test Location Shielded Room Relative humidity 48.9 % R.H.

Test Mode Mode #1 ~ #5 Atmospheric pressure 100.8 kPa

Required Criteria A Test Result PASS

Tested By Im, Jin-young

Test Data

Frequency [Hz] Axis Test Level [A/m] Result Description

50 X 1 A There was no deviation from normal

operation condition. 50 Y 1 A

50 Z 1 A

Report No.: TR-W1811-015 Page 82 of 101

ENG Co., Ltd. 135-60 Gyeongchung-daero, Gonjiam-eup, Gwangju-si, Gyeonggi-do, Korea 464-942 Report Form_01 (Rev.0)

TEL: +82-31-727-8300 FAX: +82-31-746-0800 http://www.the-eng.co.kr

7.7 VOLTAGE DIPS AND SHORT INTERRUPTIONS IMMUNITY TEST

7.7.1 Test specification

Nominal Mains Voltage (VNOM) 230 V~

Level of Reduction dip acc. to EN 55 024 500 ms at 30 % of VNOM, 10 ms at >95 % of VNOM

Level of Interruptions acc. to EN 55 024 5 s at > 95 % of VNOM

Level of Reduction dip acc. to EN 301 489-1/-17

500 ms at 30 % of VNOM,

10 ms and 20 ms at 100 % of VNOM

Level of Interruptions acc. to EN 301 489-1/-17 5 s at 100 % of VNOM

No. of dips/interruption 3

Interval 10 s

Lines for test

Type of line & length

EUT-position

AC mains of the EUT

Unshielded, 1.8 m

Table top

7.7.2 Test setup

The EUT and all local support equipment were placed on a non-metallic support 0.8 m above a referen

ce ground plane (RGP) and were put into operation according to the specified operating mode.

The test set-up photos are included in appendix XI.

7.7.3 Test result

Date of Test 2018-11-16 Temperature 21.1 °C

Test Location Shielded Room Relative humidity 49.5 % R.H.

Test Mode Mode #1 ~ #9 Atmospheric pressure 100.5 kPa

Required Criteria B (30 % dip, > 95 % dip)

C (> 95 % interruption) Test Result PASS

Tested By Im, Jin-young

Report No.: TR-W1811-015 Page 83 of 101

ENG Co., Ltd. 135-60 Gyeongchung-daero, Gonjiam-eup, Gwangju-si, Gyeonggi-do, Korea 464-942 Report Form_01 (Rev.0)

TEL: +82-31-727-8300 FAX: +82-31-746-0800 http://www.the-eng.co.kr

Test Data For Mode #1 ~ #5 acc. to EN 55 024

Test Reduction (% of VNOM)

Duration intime (ms)

Result Description

Voltage dips 30 500 A

There is no deviation from normal operating condition. > 95 10 A

Voltage

Interruptions > 95 5 000 C

The power of EUT was turned off during the test, but

returned to normal operation condition after the test.

Test Data For Mode #6 ~ #9 acc. to EN 301 489-1/-17

Test Reduction (% of VNOM)

Duration intime (ms)

Result Description

Voltage dips

30 500 A There is no deviation from normal operating condition.

100 10 A

100 20 A There is no deviation from normal operating condition.

Voltage

Interruptions 100 5 000 C

The power of EUT was turned off during the test, but

returned to normal operation condition after the test.

Report No.: TR-W1811-015 Page 84 of 101

ENG Co., Ltd. 135-60 Gyeongchung-daero, Gonjiam-eup, Gwangju-si, Gyeonggi-do, Korea 464-942 Report Form_01 (Rev.0)

TEL: +82-31-727-8300 FAX: +82-31-746-0800 http://www.the-eng.co.kr

Appendix I - Test Setup Photo: Main Terminal Continuous Disturbance Voltage Test

Mode #1 ~ #5

Report No.: TR-W1811-015 Page 85 of 101

ENG Co., Ltd. 135-60 Gyeongchung-daero, Gonjiam-eup, Gwangju-si, Gyeonggi-do, Korea 464-942 Report Form_01 (Rev.0)

TEL: +82-31-727-8300 FAX: +82-31-746-0800 http://www.the-eng.co.kr

Mode #6 ~ #9

Report No.: TR-W1811-015 Page 86 of 101

ENG Co., Ltd. 135-60 Gyeongchung-daero, Gonjiam-eup, Gwangju-si, Gyeonggi-do, Korea 464-942 Report Form_01 (Rev.0)

TEL: +82-31-727-8300 FAX: +82-31-746-0800 http://www.the-eng.co.kr

Appendix II - Test Setup Photo: Conducted Common Mode Disturbance at

Telecommunication Ports

Mode #4 ~ #5

Report No.: TR-W1811-015 Page 87 of 101

ENG Co., Ltd. 135-60 Gyeongchung-daero, Gonjiam-eup, Gwangju-si, Gyeonggi-do, Korea 464-942 Report Form_01 (Rev.0)

TEL: +82-31-727-8300 FAX: +82-31-746-0800 http://www.the-eng.co.kr

Appendix III - Test Setup Photo: Radiated Electromagnetic Field Test

Mode #1 ~ #5_Test Setup for 30 MHz – 1 GHz

Report No.: TR-W1811-015 Page 88 of 101

ENG Co., Ltd. 135-60 Gyeongchung-daero, Gonjiam-eup, Gwangju-si, Gyeonggi-do, Korea 464-942 Report Form_01 (Rev.0)

TEL: +82-31-727-8300 FAX: +82-31-746-0800 http://www.the-eng.co.kr

Mode #6 ~ #9_Test Setup for 30 MHz – 1 GHz

Report No.: TR-W1811-015 Page 89 of 101

ENG Co., Ltd. 135-60 Gyeongchung-daero, Gonjiam-eup, Gwangju-si, Gyeonggi-do, Korea 464-942 Report Form_01 (Rev.0)

TEL: +82-31-727-8300 FAX: +82-31-746-0800 http://www.the-eng.co.kr

Mode #1 ~ #5_Test Setup for 1 GHz ~ 6 GHz

Report No.: TR-W1811-015 Page 90 of 101

ENG Co., Ltd. 135-60 Gyeongchung-daero, Gonjiam-eup, Gwangju-si, Gyeonggi-do, Korea 464-942 Report Form_01 (Rev.0)

TEL: +82-31-727-8300 FAX: +82-31-746-0800 http://www.the-eng.co.kr

Mode #6 ~ #9_Test Setup for 1 GHz ~ 6 GHz

Report No.: TR-W1811-015 Page 91 of 101

ENG Co., Ltd. 135-60 Gyeongchung-daero, Gonjiam-eup, Gwangju-si, Gyeonggi-do, Korea 464-942 Report Form_01 (Rev.0)

TEL: +82-31-727-8300 FAX: +82-31-746-0800 http://www.the-eng.co.kr

Appendix IV – Test Setup Photo: Harmonic Currents & Flicker Test

Mode #5

Mode #9

Report No.: TR-W1811-015 Page 92 of 101

ENG Co., Ltd. 135-60 Gyeongchung-daero, Gonjiam-eup, Gwangju-si, Gyeonggi-do, Korea 464-942 Report Form_01 (Rev.0)

TEL: +82-31-727-8300 FAX: +82-31-746-0800 http://www.the-eng.co.kr

Appendix V - Test Setup Photo: Electrostatic Discharge Test

Mode #1 ~ #5

Mode #6 ~ #9

Report No.: TR-W1811-015 Page 93 of 101

ENG Co., Ltd. 135-60 Gyeongchung-daero, Gonjiam-eup, Gwangju-si, Gyeonggi-do, Korea 464-942 Report Form_01 (Rev.0)

TEL: +82-31-727-8300 FAX: +82-31-746-0800 http://www.the-eng.co.kr

Appendix VI - Test Setup Photo: Radio Frequency Electromagnetic Field Test

Mode #1 ~ #5

Report No.: TR-W1811-015 Page 94 of 101

ENG Co., Ltd. 135-60 Gyeongchung-daero, Gonjiam-eup, Gwangju-si, Gyeonggi-do, Korea 464-942 Report Form_01 (Rev.0)

TEL: +82-31-727-8300 FAX: +82-31-746-0800 http://www.the-eng.co.kr

Mode #6 ~ #9

Report No.: TR-W1811-015 Page 95 of 101

ENG Co., Ltd. 135-60 Gyeongchung-daero, Gonjiam-eup, Gwangju-si, Gyeonggi-do, Korea 464-942 Report Form_01 (Rev.0)

TEL: +82-31-727-8300 FAX: +82-31-746-0800 http://www.the-eng.co.kr

Appendix VII - Test Setup Photo: EFT/Burst Test

Mode #1 ~ #5

Mode #6 ~ #9

Report No.: TR-W1811-015 Page 96 of 101

ENG Co., Ltd. 135-60 Gyeongchung-daero, Gonjiam-eup, Gwangju-si, Gyeonggi-do, Korea 464-942 Report Form_01 (Rev.0)

TEL: +82-31-727-8300 FAX: +82-31-746-0800 http://www.the-eng.co.kr

Appendix VIII - Test Setup Photo: Surge Test

Mode #1 ~ #5

Mode #6 ~#9

Report No.: TR-W1811-015 Page 97 of 101

ENG Co., Ltd. 135-60 Gyeongchung-daero, Gonjiam-eup, Gwangju-si, Gyeonggi-do, Korea 464-942 Report Form_01 (Rev.0)

TEL: +82-31-727-8300 FAX: +82-31-746-0800 http://www.the-eng.co.kr

Appendix IX - Test Setup Photo: Conducted RF Field Test

Mode #1 ~ #5

Mode #6 ~ #9

Report No.: TR-W1811-015 Page 98 of 101

ENG Co., Ltd. 135-60 Gyeongchung-daero, Gonjiam-eup, Gwangju-si, Gyeonggi-do, Korea 464-942 Report Form_01 (Rev.0)

TEL: +82-31-727-8300 FAX: +82-31-746-0800 http://www.the-eng.co.kr

Appendix X - Test Setup Photo: Power Frequency Magnetic Field Test

Mode #1 ~ #5

Report No.: TR-W1811-015 Page 99 of 101

ENG Co., Ltd. 135-60 Gyeongchung-daero, Gonjiam-eup, Gwangju-si, Gyeonggi-do, Korea 464-942 Report Form_01 (Rev.0)

TEL: +82-31-727-8300 FAX: +82-31-746-0800 http://www.the-eng.co.kr

Appendix XI - Test Setup Photo: Voltage Dips & Interruption Test

Mode #1 ~ #5

Mode #6 ~ #9

Report No.: TR-W1811-015 Page 100 of 101

ENG Co., Ltd. 135-60 Gyeongchung-daero, Gonjiam-eup, Gwangju-si, Gyeonggi-do, Korea 464-942 Report Form_01 (Rev.0)

TEL: +82-31-727-8300 FAX: +82-31-746-0800 http://www.the-eng.co.kr

Appendix XII - Test Instrumentation

Name of Equipment Model Number Manufacturer Serial Number Last Cal. (Interval)

USE

For EMISSION EMI Test Receiver ESCI 7 Rohde & Schwarz 100722 2018-02-12(1Y) Test Receiver ESIB 26 Rohde & Schwarz 100298 2018-01-18(1Y)

LISN ENV4200 Rohde & Schwarz 100203 2018-01-18(1Y)

LISN ENV216 Rohde & Schwarz 100110 2018-07-27(1Y) LISN LS16C AFJ 16011403310 2018-07-27(1Y) LISN NNLK8121 SchwarzBeck 8121-163 2018-07-27(1Y)

Voltage Probe TK9420 Schwarzbeck 9420-165 2018-01-18(1Y)

Loop Antenna HFH2-Z2 Rohde & Schwarz 100341 2017-06-15(2Y)

8-Wire ISN CAT 3 CAT3 8158 Schwarzbeck CAT3 8158 #70 2018-01-22(1Y)

8-Wire ISN CAT 5 CAT5 8158 Schwarzbeck CAT5 8158 #126 2018-01-22(1Y) 8-Wire ISN CAT 6 NTFM 8158 Schwarzbeck NTFM 8158 #95 2018-01-22(1Y) Test Receiver ESU Rohde & Schwarz 100303 2018-01-18(1Y) TRILog Broadband Antenna

VULB9163 Schwarzbeck 9163-799 2017-10-23(2Y)

DOPPEL STEG HORN Antenna

HF 907 Rohde & Schwarz 102426 2017-01-06(2Y)

Preamp (1-18) GHz SCU 18D Rohde & Schwarz 19006450 2018-04-23(1Y) Preamp 9 kHz-1 GHz 310N Sonoma Instrument 344015 2018-01-18(1Y) Attenuators 6 dB Rohde & Schwarz 272.4110.50 2018-01-18(1Y) Antenna Master MA4000-EP INNCO SYSTEM 4600814 N/A Turn Table DT3000-3t INNCO SYSTEM 1310814 N/A

CO3000 Controller CO3000-4PORT

INNCO SYSTEM CO3000/806/34130814/L

N/A

Digital Power Analyzer For Harmonic & Flicker

DPA 500 EM Test V0713102356 2018-01-25(1Y)

AC Power Source ACS 500 EM Test V0713102357 2018-07-27(1Y) For IMMUNITY

ESD Simulator ESS-2000 NoiseKen ESS04Z3791 2017-12-04(1Y) ESD Gun TC-815R NoiseKen ESS04Z3850 2017-12-04(1Y) IMS System IMS Rohde & Schwarz 100018 2018-01-19(1Y) Vector Signal Generator SMBV100A Rohde & Schwarz 257560 2018-01-18(1Y) Power Sensor NRP-Z11 Rohde & Schwarz 102855 2018-01-19(1Y) Power Sensor NRP-Z81 Rohde & Schwarz 101507 2018-07-27(1Y) Power Sensor NRP-Z81 Rohde & Schwarz 102692 2018-07-27(1Y) Power meter NRP2 Rohde & Schwarz 103736 2018-07-27(1Y) Field Probe FL7040 Amplifier Research 0336775 2018-03-19(1Y)

High Gain Log-Periodic Antenna

HL046E Rohde & Schwarz 100014 2018-03-12(1Y)

DOPPEL STEG HORN Antenna

HF906 Rohde & Schwarz 100332 2017-02-13(2Y)

Power Amplifier 250W1000A Amplifier Research 0320414 2018-03-12(1Y) Power Amplifier 60SIG3 Amplifier Research 0320442 2018-03-12(1Y) Amplifier SSA505A Sungsan SSEC0003 2018-10-31(1Y) Directional Coupler DC6180A Amplifier Research 0335536 2018-01-18(1Y) Directional Coupler DC7144A Amplifier Research 0320556 2018-01-18(1Y) Ultra Compact Simulator UCS 500 N7 EM Test V1047108018 2017-12-19(1Y)

Report No.: TR-W1811-015 Page 101 of 101

ENG Co., Ltd. 135-60 Gyeongchung-daero, Gonjiam-eup, Gwangju-si, Gyeonggi-do, Korea 464-942 Report Form_01 (Rev.0)

TEL: +82-31-727-8300 FAX: +82-31-746-0800 http://www.the-eng.co.kr

Name of Equipment Model Number Manufacturer Serial Number Last Cal. (Interval)

USE

Combined Coupling Decoupling Net.

CNI 503 B7 EM Test V1047108019 2017-12-19(1Y)

Capacitive Coupling Clamp

HFK EM Test 0306-45 2017-07-28(1Y)

Signal Generator SMA 100A Rohde & Schwarz 101047 2018-01-18(1Y)

Attenuator 150-A-FFN-06 Bird Technologies Group

0605 2018-01-18(1Y)

Power Amplifier 150A250 Amplifier Research 313455 2018-02-14(1Y)

CDN FCC-801-M1-16A

Fisher Custom 06006 2018-01-18(1Y)

CDN FCC-801-M2-16A

Fisher Custom 06004 2018-01-18(1Y)

CDN FCC-801-M3-16A

Fisher Custom 06006 2018-07-27(1Y)

CDN FCC-801-M5-16A

Fisher Custom 03006 2018-01-29(1Y)

EM Injection Clamp F-203I-23MM Fisher Custom 490 2018-01-29(1Y) Directional Coupler DC2600A Amplifier Research 0334631 2018-07-27(1Y)

Termination 300-T-MN Bird Technologies Group

0526 2018-02-14(1Y)

Power Sensor NRP-Z91 Rohde & Schwarz 100617 2018-07-27(1Y) Magnetic field Antenna MS 100 EM Test 1206-42 2018-04-05(1Y) Current Transformer MC 2630 EM Test 0912-66 2018-04-05(1Y) Ultra Compact Generator UCS 500 M6B EM Test AG V0626101562 2018-01-18(1Y) Motorized Variac MV 2616 EM Test AG V0626101563 2018-01-18(1Y) AC & DC Power Source 3150AFX-4L PACIFIC 110634101 2018-03-16(1Y)