Embla® XactTrace™
The Embla XactTrace is a comprehensive, respiratory effort belt solution.Whether your needs are infection control, financial, ease of use or protocol preference, we have the clear universal solution for neonates through bariatric patients.
Embla® XactTrace™ Respiratory Effort Belts
Embla XactTrace Pre-sized Single Use Belt*Pre-Sized for standard sizes: Pediatric, Small, Medium and Large. These fabric belts have pre-attached snap terminals for a quick and easy set up. No threading of the material into the lock is required. No cleaning involved since they are single patient use belts. The same high quality RIP technology you are accustomed to in our reusable XactTrace belts continues to provide excellent patient data.
Embla XactTrace Single Use Belt*Exactly the right belt for the right patient fit. Cut to fit the patient size exactly. Particularly useful for infants and bariatric patients where no standard size exists. No cleaning involved with this disposable belt. Proven RIP technology provides quality patient data.
Embla XactTrace Reusable Belt*Does not require any additional modules and plugs directly into the Embla amplifiers. Low profile lock ensures patient comfort. May be reused and cleaned per manufacturer’s recommendations. Available in multiple sizes: Pediatric, Small, Medium and Large.
Embla XactTrace Universal BeltThe XactTrace Universal Belt is a one size fits all, reusable, RIP belt solution for non-Embla amplifiers. With battery power on board, the XactTrace Universal Belt eliminates the need for cumbersome 3rd Party interfaces.
*Direct connection to the amplifier eliminates bulky interfaces required by many other systems since we provide power to the belts through our amplifiers.
P/N 011236D
Natus Neurology Incorporated 3150 Pleasant View RoadMiddleton, WI 53562 USATel: 1-800-356-0007 1-608-829-8500Fax: 1-608-829-8709www.natus.com
Embla Systems 1 Hines Road, Suite 202Kanata, OntarioCanada K2K 3C7Tel: 1-888-662-7632 1-716-551-6900Fax: 1-775-860-5726
© 2014 Natus Medical Incorporated. All Rights Reserved. All product names appearing on this document are trademarks or registered trademarks owned, licensed to, promoted or distributed by Natus Medical Incorporated, its subsidiaries or affiliates.
Embla XactTrace
Ordering informationItem Part Number
XactTrace Pre-Sized Single Use Belt Pediatric 011516
XactTrace Pre-Sized Single Use Belt Small 011517
XactTrace Pre-Sized Single Use BeltMedium 011518
XactTrace Pre-Sized Single Use BeltLarge 011520
XactTrace Snap SensorAbdomen for Pre-Sized Single Use Belt 011521
XactTrace Snap SensorThorax for Pre-Sized Single Use Belt 011522
XactTrace Snap Sensor CableAbdomen, 78” cable for Pre-Sized Single Use Belt 013224
XactTrace Snap Sensor CableThorax, 78” cable for Pre-Sized Single Use Belt 013225
Embletta Gold Inline Inductor For Pre-Sized Single Use Belt 013382
XactTrace Universal KitOne size fits all 1421091
XactTrace Single-Use Rolls(65.6 ft/20 m) 1421000
XactTrace Single-Use LockAbdomen 1421020
XactTrace Single-Use LockThorax 1421022
XactTrace Reusable BeltSmall Abdomen 1421032
XactTrace Reusable BeltSmall Thorax 1421033
XactTrace Reusable BeltMedium Abdomen 1421034
XactTrace Reusable BeltMedium Thorax 1421035
XactTrace Reusable BeltLarge Abdomen 1421036
XactTrace Reusable BeltLarge Thorax 1421037
Reusable and single-use options available (For use with Embletta® and Embla PSG Amplifier Line)In addition to eliminating false paradoxing, additional derived channels are available, including:
• XFlow™ is a semi-quantitative measure of inspiratory and expiratory flow, providing a complementary flow signal for studies without airflow sensors. XFlow is a reliable backup and great tool for titrations.
• XSum™ is the summation of the abdominal and thoracic signals providing a semi-quantitative measurement of lung volume.
• RMI™ (Respiratory Mechanics Instability) is a proprietary algorithm that assesses the severity of Sleep Disordered Breathing by analyzing the phase relationship between the abdomen and thorax.
• Phase Analysis displays (in degrees) the phase relationship between the abdomen and the thorax for evaluation and analysis of paradoxical breathing.
Polarity of the trace is always consistent, eliminating false paradoxing.
Example of derived Xflow and XSum signals when used with Embletta and Embla line of PSG amplifiers.
ServiceNatus Neurology is committed to providing exemplary service to our customers. Our dedicated and experienced Customer Service Team will assist with every aspect of an order. To support our products, we provide factory-trained Field Technicians and Clinical Application Specialists for onsite support. Additionally, we provide an in-house Technical Support Team, staffed with experts, and a strong distribution network in International Markets to offer a wide range of service options. Allowing our customers more time to care for their patients is our goal. Customer loyalty is our reward.
SuppliesNatus Neurology offers a full range of neurodiagnostic accessories and supplies promoting patient comfort. Our dedicated customer service team provides a streamlined order and shipping process to save you time and money.
To learn more about Natus Neurology Service Programs or our full line of
Supplies and Accessories, contact your local distributor or sales representative.US Customers Call: 1-888-662-7632