Self-Monitoring Electronic Transformer Features / Specifications :
Self-Monitoring model Input voltage : 220-240VAC 50/60Hz Output voltage : 11.4VAC Overload, short-circuit protection Fully dimmable with resistive and inductive dimmers Auto re-set thermal protection 1.0KV surge protection EN61547+A1 Suitable for use in commercial or light industrial installation. Safety compliance – complying to EN61347 EMC compliance – EN55015, EN61000, EN61547+A1 2 years guarantee
LMET-003
LMET-004
LMET-001/LMET-002
LMET-005
LMET-006
Model LMET-001 LMET-002 LMET-003 LMET-004 LMET-005 LMET-006
Output frequency (KHz) 38.4 38.4 35.6 26.5 30.5 20.6
Normal power (W) 20~60 20~70 35~105 50~150 50~210 50~300
Line current (Amp) 0.26 0.29 0.43 0.62 0.87 1.3
Input terminal block (pairs) 2 2 2 2 2 2
Output terminal block (pairs) 3 3 3 3 4 3
Max. ambient temperature (Ta) 50ºC 50ºC 45ºC 45ºC 45ºC 45ºC
Max. case temperature (Tc) 80ºC 80ºC 80ºC 80ºC 80ºC 80ºC
Dimensions (mm) 123.5x38.5x24 123.5x38.5x24 156x38x25.5 158.5x45.5x29 176x47x35 218.5x55x37
【1】
Electronic Transformer
Self-Monitoring Electronic Transformer Features / Specifications :
Self-Monitoring model Input voltage : 220-240VAC 50/60Hz Output voltage : 11.4VAC Overload, short-circuit protection Fully dimmable with resistive and inductive dimmers Auto re-set thermal protection 1.0KV surge protection EN61547+A1 Suitable for use in commercial or light industrial installation. Safety compliance – complying to EN61347 EMC compliance – EN55015, EN61000, EN61547+A1 2 years guarantee
LMET-007
LMET-008
LMET-009
LMET-010
LMET-011
LMET-012
Model LMET-007 LMET-008 LMET-009 LMET-010 LMET-011 LMET-012
Output frequency (KHz) 38.4 38.4 35.6 26.5 30.5 20.6
Normal power (W) 20~60 20~70 35~105 50~150 50~210 50~300
Line current (Amp) 0.27 0.29 0.43 0.62 0.87 1.25
Input terminal block (pairs) 2 2 2 2 2 2
Output terminal block (pairs) 3 3 3 3 4 3
Max. ambient temperature (Ta) 50ºC 50ºC 45ºC 45ºC 45ºC 45ºC
Max. case temperature (Tc) 75ºC 80ºC 75ºC 80ºC 80ºC 80ºC
Dimensions (mm) 123.5x38.5x24 123.5x38.5x24 156x38x25.5 158.5x45.5x29 176x47x35 218.5x55x37
【2】
Electronic Transformer
Self-Monitoring Electronic Transformer Features / Specifications :
Self-Monitoring model Input voltage : 220-240VAC 50/60Hz Output voltage : 11.4VAC Overload, short-circuit protection Fully dimmable with resistive and inductive dimmers Auto re-set thermal protection 1.0KV surge protection EN61547+A1 Suitable for use in commercial or light industrial installation. Safety compliance – complying to EN61347 EMC compliance – EN55015, EN61000, EN61547+A1 2 years guarantee
Model LMET-013 LMET-014 LMET-015 LMET-016 LMET-017
Output frequency (KHz) 43.8 48 46 37 30.3
Normal power (W) 20~60 20~70 35~105 50~150 50~210
Line current (Amp) 0.26 0.30 0.46 0.65 0.87
Input terminal block (pairs) 2 2 2 2 2
Output terminal block (pairs) 3 3 3 3 3
Max. ambient temperature (Ta) 50ºC 45ºC 45ºC 45ºC 45ºC
Max. case temperature (Tc) 75ºC 75ºC 75ºC 75ºC 80ºC
Dimensions (mm) 126x39.5x24.5 150x38x25 150x38x25 158x45.5x29 181x48x35
【3】
Electronic Transformer
Electronic Transformer Features / Specifications :
Self-Monitoring model Input voltage : 220-240VAC 50/60Hz Output voltage : 11.4VAC Overload, short-circuit protection Fully dimmable with resistive and inductive dimmers Auto re-set thermal protection 1.0KV surge protection EN61547+A1 Suitable for use in commercial or light industrial installation. Safety compliance – complying to EN61347 EMC compliance – EN55015, EN61000, EN61547+A1 2 years guarantee
LMET-018/LMET-019
LMET-020/LMET-021/LMET-022/LMET-023
Model LMET-018 LMET-019 LMET-020 LMET-021 LMET-022 LMET-023
Output frequency (KHz) 38.4 38.4 35.6 26.5 30.5 20.6
Normal power (W) 20~60 20~70 35~105 50~150 50~210 50~300
Line current (Amp) 0.26 0.29 0.43 0.62 0.87 1.3
Input terminal block (pairs) 2 2 2 2 2 2
Output terminal block (pairs) 3 3 3 3 4 3
Max. ambient temperature (Ta) 50ºC 50ºC 45ºC 45ºC 45ºC 45ºC
Max. case temperature (Tc) 75ºC 80ºC 75ºC 80ºC 80ºC 80ºC
Dimensions (mm) 123.5x38.5x24 123.5x38.5x24 156x38x25.5 158.5x45.5x29 176x47x35 218.5x55x37
【4】
Electronic Transformer
Electronic Transformer – IP68 Waterproof <protected against submersion in water> Features / Specifications :
Controlling with low voltage halogen bulbs Input voltage : 220-240VAC 50/60Hz Output voltage : 11.4VAC Using with low voltage pond/pool & outdoor light Protected against submergence in water up to 2 meters Extend bulb life for soft start Reduced size and weight for ingenious design Over-load and short-circuit protection with self-resetting Safety compliance – complying to EN61347 EMC compliance – EN55015, EN61000, EN61547 2 years guarantee
LMET-024 LMET-025
LMET-026 LMET-027
LMET-028 LMET-029
Model LMET-024 LMET-025 LMET-026 LMET-027 LMET-028 LMET-029
Output frequency (KHz) 40 35.6 40 35.6 39 36
Normal power (W) 20~60 35~105 20~60 35~105 20~60 35~105
Line current (Amp) 0.26 0.45 0.26 0.45 0.26 0.45
Input terminal block (pairs) Pre wire Pre wire Pre wire Pre wire 1 1
Output terminal block (pairs) Pre wire Pre wire Pre wire Pre wire 1 1
Max. ambient temperature (Ta) 50ºC 45ºC 50ºC 45ºC 50ºC 45ºC
Max. case temperature (Tc) 65ºC 65ºC 70ºC 70ºC 80ºC 80ºC
Dimensions (mm) 135x60x33.5 135x60x33.5 129x36x 26 129x36x26 135x43x20 135x43x20
【5】
Electronic Transformer
Track Lighting Electronic Transformer Features / Specifications :
Controlling with low voltage halogen bulbs Input voltage : 220-240VAC 50/60Hz Output voltage : 11.4VAC Integrated terminal for easy installation Extend bulb life for soft start Reduced size and weight for ingenious design Over-load and short-circuit protection with self-resetting Safety compliance – complying to EN61347 EMC compliance – EN55015, EN61000, EN61547 2 years guarantee
LMET-030
LMET-031
LMET-032
LMET-033
LMET-034
LMET-035
Model LMET-030 LMET-031 LMET-032 LMET-033 LMET-034 LMET-035
Output frequency (KHz) 36 30 38.4 35.6 26.5 30.5
Normal power (W) 20~60 20~60 20~60 35~105 50~150 50~210
Line current (Amp) 0.26 0.26 0.26 0.43 0.62 0.87
Input terminal block (pairs) Connect connect 2 2 2 2
Output terminal block (pairs) Cord Cord Connect Connect Connect Connect
Max. ambient temperature (Ta) 50ºC 50ºC 50ºC 45ºC 45ºC 45ºC
Max. case temperature (Tc) 80ºC 75ºC 80ºC 80ºC 80ºC 80ºC
Dimensions (mm) 122x35x43 105.5x35x41 161.5x40x35 194x40x35.5 197x47x39 215.5x53.5x43
【6】
Electronic Transformer
Plug-In Electronic Transformer Features / Specifications :
Controlling with low voltage halogen bulbs Input voltage : 220-240VAC 50/60Hz Output voltage : 11.4VAC Integrated terminal for easy installation Extend bulb life for soft start Reduced size and weight for ingenious design Over-load and short-circuit protection with self-resetting Safety compliance – complying to EN61347 EMC compliance – EN55015, EN61000, EN61547 2 years guarantee
LMET-036
LMET-037
LMET-038
Model LMET-036 LMET-037 LMET-038
Output frequency (KHz) 40 40 40
Normal power (W) 20~60 20~60 20~60
Line current (Amp) 0.26 0.26 0.26
Input terminal block (pairs) Continental plug Continental plug Continental plug
Output terminal block (pairs) Pre wire Pre wire Pre wire
Max. ambient temperature (Ta) 50ºC 50ºC 50ºC
Max. case temperature (Tc) 75ºC 75ºC 75ºC
Dimensions (mm) 95x41x67 95x62x48 95x56x41
【7】
Electronic Transformer
Round type Electronic Transformer Features / Specifications :
Input voltage : 220-240VAC 50/60Hz Output voltage : 11.4VAC Integrated into luminaries or surface mounting Extend bulb life for soft start Reduced size and weight for ingenious design Over-load and short-circuit protection with self-resetting Safety compliance – complying to EN61347 EMC compliance – EN55015, EN61000, EN61547 2 years guarantee
LMET-039 LMET-040 LMET-041 LMET-042/LMET-043
Model LMET-039 LMET-040 LMET-041 LMET-042 LMET-043
Output frequency (KHz) 40 39.8 26.5 21.3 20.6
Normal power (W) 20~60 35~105 50~150 50~210 50~300
Line current (Amp) 0.26 0.45 0. 62 0.87 1.25
Input terminal block (pairs) 1 1 1 1 1
Output terminal block (pairs) 1 1 1 1 2
Max. ambient temperature (Ta) 50ºC 45ºC 45ºC 45ºC 45ºC
Max. case temperature (Tc) 80ºC 80ºC 80ºC 80ºC 80ºC
Dimensions (mm) 76x76x26 86x86x27 105x105x32 110x110x36 118x118x40
【8】
Electronic Transformer
Round type Electronic Transformer Features / Specifications :
Input voltage : 220-240VAC 50/60Hz Output voltage : 11.4VAC Integrated into luminaries or surface mounting Extend bulb life for soft start Reduced size and weight for ingenious design Over-load and short-circuit protection with self-resetting Safety compliance – complying to EN61347 EMC compliance – EN55015, EN61000, EN61547 2 years guarantee
Model LMET-044 LMET-045 LMET-046 LMET-047
Output frequency (KHz) 40 38 39.8 26.5
Normal power (W) 20~60 20~80 35~105 50~150
Line current (Amp) 0.26 0.36 0. 45 0.62
Input terminal block (pairs) 1 1 1 1
Output terminal block (pairs) 1 1 1 1
Max. ambient temperature (Ta) 50ºC 50ºC 45ºC 45ºC
Max. case temperature (Tc) 80ºC 85ºC 80ºC 80ºC
Dimensions (mm) 76x76x26 76x76x27 86x86x27 105x105x32
【9】
Electronic Transformer
Flat type Electronic Transformer Features / Specifications :
Controlling with low voltage halogen bulbs Input voltage : 220-240VAC 50/60Hz Output voltage : 11.4VAC Integrated terminal for easy installation Extend bulb life for soft start Reduced size and weight for ingenious design Over-load and short-circuit protection with self-resetting Safety compliance – complying to EN61347 EMC compliance – EN55015, EN61000, EN61547 2 years guarantee
LMET-049
LMET-050
LMET-048
LMET-051
LMET-052
Model LMET-048 LMET-049 LMET-050 LMET-051 LMET-052
Output frequency (KHz) 40 35 39.8 32 23
Normal power (W) 20~60 20~60 35~105 35~120 50~150
Line current (Amp) 0.26 0.35 0.46 0.52 0.65
Input terminal block (pairs) 1 1 1 1 1
Output terminal block (pairs) 1 4 3 3 3
Max. ambient temperature (Ta) 50ºC 40ºC 40ºC 40ºC 40ºC
Max. case temperature (Tc) 80ºC 65ºC 90ºC 75ºC 75ºC
Dimensions (mm) 85x41x23 129x45x20 146x44x24 146x44x24 166x41x31
【10】
Electronic Transformer
Flat type Electronic Transformer Features / Specifications :
Controlling with low voltage halogen bulbs Input voltage : 220-240VAC 50/60Hz Output voltage : 11.4VAC Integrated terminal for easy installation Extend bulb life for soft start Reduced size and weight for ingenious design Over-load and short-circuit protection with self-resetting Safety compliance – complying to EN61347 EMC compliance – EN55015, EN61000, EN61547 2 years guarantee
LMET-053 LMET-054 LMET-055 LMET-056
Model LMET-053 LMET-054 LMET-055 LMET-056
Output frequency (KHz) 40 39.8 26.5 30.5
Normal power (W) 20~60 35~105 50~150 50~210
Line current (Amp) 0.26 0.45 0.65 0.91
Input terminal block (pairs) 1 1 2 2
Output terminal block (pairs) 1 3 3 4
Max. ambient temperature (Ta) 50ºC 50ºC 45ºC 45ºC
Max. case temperature (Tc) 85ºC 70ºC 75ºC 82ºC
Dimensions (mm) 85.5x41x23 147x44.5x24.5 151x47x28.5 164x49.5x33
【11】
Electronic Transformer
Flat type Electronic Transformer Features / Specifications :
Controlling with low voltage halogen bulbs Input voltage : 220-240VAC 50/60Hz Output voltage : 11.4VAC Integrated terminal for easy installation Extend bulb life for soft start Reduced size and weight for ingenious design Over-load and short-circuit protection with self-resetting Safety compliance – complying to EN61347 EMC compliance – EN55015, EN61000, EN61547 2 years guarantee
LMET-057/LMET-058 LMET-059/LMET-060 LMET-061
Model LMET-057 LMET-058 LMET-059 LMET-060 LMET-061
Output frequency (KHz) 40 35.6 37.7 24.6 37
Normal power (W) 20~60 35~105 20~60 35~105 35~105
Line current (Amp) 0.26 0.43 0.26 0.45 0.45
Input terminal block (pairs) 1 1 2 2 1
Output terminal block (pairs) 1 2 3 AMP 3 AMP 1
Max. ambient temperature (Ta) 40ºC 45ºC 50ºC 50ºC 50ºC
Max. case temperature (Tc) 65ºC 75ºC 80ºC 75ºC 75ºC
Dimensions (mm) 91x41x28 111.5x42.5x30.5 130x36x21 142x37.5x26 128x48x26.5
【12】
Electronic Transformer
Flat type Electronic Transformer Features / Specifications :
Controlling with low voltage halogen bulbs Input voltage : 220-240VAC 50/60Hz Output voltage : 11.4VAC Integrated terminal for easy installation Extend bulb life for soft start Reduced size and weight for ingenious design Over-load and short-circuit protection with self-resetting Safety compliance – complying to EN61347 EMC compliance – EN55015, EN61000, EN61547 2 years guarantee
LMET-062/LMET-063 LMET-064/LMET-065
Model LMET-062 LMET-063 LMET-064 LMET-065
Output frequency (KHz) 35 37 37.9 37.6
Normal power (W) 20~60 35~105 20~60 35~105
Line current (Amp) 0.26 0.45 0.26 0.45
Input terminal block (pairs) 1 1 1 1
Output terminal block (pairs) 1 1 1 1
Max. ambient temperature (Ta) 50ºC 50ºC 50ºC 45ºC
Max. case temperature (Tc) 75ºC 75ºC 70ºC 70ºC
Dimensions (mm) 91x41x28 111.5x42.5x30.5 130x36x21 142x37.5x26
【13】
Electronic Transformer
Flat type Electronic Transformer Features / Specifications :
Controlling with low voltage halogen bulbs Input voltage : 220-240VAC 50/60Hz Output voltage : 11.4VAC Integrated terminal for easy installation Extend bulb life for soft start Reduced size and weight for ingenious design Over-load and short-circuit protection with self-resetting Safety compliance – complying to EN61347 EMC compliance – EN55015, EN61000, EN61547 2 years guarantee
LMET-067
LMET-068
LMET-066
LMET-069
LMET-070
Model LMET-066 LMET-067 LMET-068 LMET-069 LMET-070
Output frequency (KHz) 37.9 37.9 30.3 40 37
Normal power (W) 20~60 20~60 20~60 20~60 20~60
Line current (Amp) 0.26 0.26 0.25 0.26 0.26
Input terminal block (pairs) 1 1 2 1 1
Output terminal block (pairs) 1 1 1 1 1
Max. ambient temperature (Ta) 50ºC 50ºC 50ºC 50ºC 50ºC
Max. case temperature (Tc) 75ºC 75ºC 75ºC 75ºC 75ºC
Dimensions (mm) 110.5x36x22.5 94x37x28 124x41x26 100x41x28 133x40x26
【14】
Electronic Transformer
Flat type Electronic Transformer Features / Specifications :
Controlling with low voltage halogen bulbs Integrated terminal for easy installation Extend bulb life for soft start Reduced size and weight for ingenious design Over-load and short-circuit protection with self-resetting Safety compliance – complying to EN61347 EMC compliance – EN55015, EN61000, EN61547 2 years guarantee
LMET-071 LMET-072 LMET-073
Model LMET-071 LMET-072 Model LMET-073
Input voltage (VAC) 220-240VAC 50/60Hz Input voltage (VAC) 240VAC 50Hz
Output voltage (VAC) 11.4VAC 11.4VAC Output voltage (V DC) 11V DC at terminal side 9.8V DC at end side (3.5~4mm)
Output frequency (KHz) 37 37 Output load (V) 12V halogen bulb
Normal power (W) 20~60 20~60 Normal power (W) 35W~105W
Line current (Amp) 0.26 0.26 Max. length of output cable 12 meters
Input terminal block (pairs) 1 Pre wire Min. length of output cable 1 meter
Output terminal block (pairs) 1 Pre wire Short-circuit protection Auto re-set
Max. ambient temperature (Ta) 50ºC 50ºC Overload protection 105W x 2
Max. case temperature (Tc) 80ºC 80ºC Over temperature protection 115ºC
Dimensions (mm) 102x38x18 82x33x20 Dimensions (mm) 210x60x35
【15】
Electronic Transformer
Flat type Electronic Transformer Features / Specifications :
Controlling with low voltage halogen bulbs Input voltage : 220-240VAC 50/60Hz Output voltage : 11.4VAC Integrated terminal for easy installation Extend bulb life for soft start Reduced size and weight for ingenious design Over-load and short-circuit protection with self-resetting Safety compliance – complying to EN61347 EMC compliance – EN55015, EN61000, EN61547 2 years guarantee
LMET-074
LMET-075
LMET-076
LMET-077
LMET-079
LMET-078
Model LMET-074 LMET-075 LMET-076 LMET-077 LMET-078 LMET-079
Output frequency (KHz) 39 40 40 40 35.6 45
Normal power (W) 20~60 20~60 20~60 20~60 20~60 20~80
Line current (Amp) 0.26 0.26 0.26 0.26 0.26 0.35
Input terminal block (pairs) Pre wire Pre wire 1 Pre wire Pre wire 1
Output terminal block (pairs) Pre wire Pre wire Pre wire Pre wire Pre wire Pre wire
Max. ambient temperature (Ta) 50ºC 50ºC 50ºC 50ºC 50ºC 40ºC
Max. case temperature (Tc) 75ºC 75ºC 75ºC 80ºC 75ºC 75ºC
Dimensions (mm) 101x37x26 101x37x23 109x43x24 81x40.5x23.5 94x36.5x27.5 94.5x40.5x24.5
【16】
Electronic Transformer
Flat type Electronic Transformer Features / Specifications :
Controlling with low voltage halogen bulbs Input voltage : 220-240VAC 50/60Hz Output voltage : 11.4VAC Integrated terminal for easy installation Extend bulb life for soft start Reduced size and weight for ingenious design Over-load and short-circuit protection with self-resetting Safety compliance – complying to EN61347 EMC compliance – EN55015, EN61000, EN61547 2 years guarantee
LMET-080 LMET-081 <Self-Monitoring>
LMET-082 LMET-083
Model LMET-080 LMET-081 LMET-082 LMET-083
Output frequency (KHz) 38.3 44 34.1 40
Normal power (W) 20~60 20~60 20~60 20~60
Line current (Amp) 0.26 0.26 0.26 0.26
Input terminal block (pairs) Pre wire Pre wire Pre wire Pre wire
Output terminal block (pairs) Pre wire Pre wire Pre wire Pre wire
Max. ambient temperature (Ta) 50ºC 50ºC 50ºC 50ºC
Max. case temperature (Tc) 75ºC 75ºC 75ºC 75ºC
Dimensions (mm) 100.5x40x20 102x40x30 91.5x34x21.5 105x39.5x27
【17】
Electronic Transformer
Super Flat type Electronic Transformer Features / Specifications :
Controlling with low voltage halogen bulbs Input voltage : 220-240VAC 50/60Hz Output voltage : 11.4VAC 16~19mm low profile suitable for furniture and cabinet Integrated AMP plugs and terminal for easy installation Extend bulb life for soft start Reduced size and weight for ingenious design Over-load and short-circuit protection with self-resetting Safety compliance – complying to EN61347 EMC compliance – EN55015, EN61000, EN61547 2 years guarantee
LMET-084/LMET-085/LMET-086/LMET-087
Model LMET-084 LMET-085 LMET-086 LMET-087
Output frequency (KHz) 39 36 39 36
Normal power (W) 10~60 20~80 35~105 35~120
Line current (Amp) 0.27 0.35 0.45 0.52
Input terminal block (pairs) 1 1 1 1
Output terminal block (pairs) 6 AMP 6 AMP 6 AMP 6 AMP
Max. ambient temperature (Ta) 50ºC 50ºC 45ºC 45ºC
Max. case temperature (Tc) 70ºC 75ºC 75ºC 75ºC
Dimensions (mm) 135.5x45x15.5 135.5x45x15.5 135X45x15.5 135.5x45x15.5
【18】
Electronic Transformer
Super Flat type Electronic Transformer Features / Specifications :
Controlling with low voltage halogen bulbs Input voltage : 220-240VAC 50/60Hz Output voltage : 11.4VAC 16~19mm low profile suitable for furniture and cabinet Integrated AMP plugs and terminal for easy installation Extend bulb life for soft start Reduced size and weight for ingenious design Over-load and short-circuit protection with self-resetting Safety compliance – complying to EN61347 EMC compliance – EN55015, EN61000, EN61547 2 years guarantee
LMET-089/LMET-091 LMET-088/LMET-090
Model LMET-088 LMET-089 LMET-090 LMET-091
Output frequency (KHz) 39 39 36 36
Normal power (W) 20~60 20~60 35~105 35~105
Line current (Amp) 0.26 0.26 0.45 0.45
Input terminal block (pairs) 1 2 1 2
Output terminal block (pairs) 3 3 AMP 3 3 AMP
Max. ambient temperature (Ta) 50ºC 50ºC 45ºC 45ºC
Max. case temperature (Tc) 80ºC 75ºC 80ºC 80ºC
Dimensions (mm) 127x41x18.5 142x41x18.5 127x41x18.5 142x41x18.5
【19】
Electronic Transformer
Flat type Electronic Transformer – UL Features / Specifications :
Using in low voltage halogen bulbs Input voltage : 120VAC 60Hz Output voltage : 11.4VAC Extend bulb life for soft start Reduced size and weight for ingenious design Over-load and short-circuit protection with self-resetting Safety compliance – complying to EN61347 EMC compliance – EN55015, EN61000, EN61547 2 years guarantee
LMET-092/LMET-093/LMET-094/LMET-095
LMET-096 LMET-097 LMET-098 <Track Lighting>
Model LMET-092 LMET-093 LMET-094 LMET-095 LMET-096 LMET-097 LMET-098
Output frequency (KHz) 40 39.8 40 35.6 37 37 23
Normal power (W) 20~60 20~80 35~105 35~150 20~50 20~50 20~60
Line current (Amp) 0.5 0.67 0.88 1.25 0.41 0.41 0.5
Input terminal block (pairs) Pre wire Pre wire Pre wire Pre wire 1 Pre wire Connect
Output terminal block (pairs) Pre wire Pre wire Pre wire Pre wire 1 Pre wire Pre wire
Max. ambient temperature (Ta) 50ºC 50ºC 45ºC 45ºC 50ºC 50ºC 50ºC
Max. case temperature (Tc) 65ºC 70ºC 80ºC 80ºC 80ºC 80ºC 75ºC
Dimensions (mm) 55x33x26 79x36x26 79x36x26 96x39x27.5 102x38x18 82x23x20 105x35x36.5
【20】
Electronic Transformer
Flat type Electronic Transformer – UL Features / Specifications :
Using in low voltage halogen bulbs Input voltage : 120VAC 60Hz Output voltage : 11.4VAC Extend bulb life for soft start Reduced size and weight for ingenious design Over-load and short-circuit protection with self-resetting Safety compliance – complying to EN61347 EMC compliance – EN55015, EN61000, EN61547 2 years guarantee
LMET-099
LMET-100
LMET-101 LMET-102
LMET-103
LMET-104
LMET-105 <Plug-in>
Model LMET-099 LMET-100 LMET-101 LMET-102 LMET-103 LMET-104 LMET-105
Output frequency (KHz) 30 23 25 25 25 22 45
Normal power (W) 35~105 50~150 20~50 20~50 20~60 20~75 20~60
Line current (Amp) 0.88 1.25 0.41 0.5 0.5 0.6 0.5
Input terminal block (pairs) 1 1 1 2 Pre wire Pre wire Continental plug
Output terminal block (pairs) 3 3 1 3 AMP Pre wire Pre wire Continental plug
Max. ambient temperature (Ta) 40ºC 40ºC 40ºC 45ºC 45ºC 50ºC 45ºC
Max. case temperature (Tc) 75ºC 75ºC 80ºC 80ºC 80ºC 75ºC 75ºC
Dimensions (mm) 166x44x24 166x41x31 85x41x22 142x41x19 81x41x24 81x40x24 94.5x40.5x30
【21】
Electronic Transformer EURO Plug-in & Built-in type
EURO Electronic Transformer Features / Specifications :
Input voltage : 220-240VAC 50/60Hz Output voltage : 11.4VAC Rated loading : 10W ~ 60W Max. ambient temperature Ta = 45ºC Max. case temperature Tc = 75ºC Over heat & over load protection Output short-circuit protect
Soft start & extend use life Output voltage is safety extra low voltage Hi-Pot 4K VAC Fire prevention PC case Fit to all kind of 12V halogen lamps Compliance safety and EMC directive
LMET-106
EURO Plug-in Electronic Transformer
Certificate compliance : EN61347-1:2008; EN61347-2-2:2001+A1+A2; EN55015:2006; EN61547:1995+A1; EN61000-3-2:2006; EN61000-3-3:1995+A1+A2 ZEK01.2-08/12.08
LMET-107
EURO Built-in Electronic Transformer
Certificate compliance : EN61347-1:2008; EN61347-2-2:2001+A1+A2; EN55015:2006; EN61547:1995+A1; EN61000-3-2:2006; EN61000-3-3:1995+A1+A2
【22】
Electronic Transformer EURO Independent type
EURO Independent Electronic Transformer Features / Specifications :
Input voltage : 220-240VAC 50/60Hz Output voltage : 11.4VAC Rated loading : 10W ~ 60W Max. ambient temperature Ta = 45ºC Max. case temperature Tc = 75ºC Over heat & over load protection Output short-circuit protect
Soft start & extend use life Output voltage is safety extra low voltage Hi-Pot 4K VAC Fire prevention PC case Fit to all kind of 12V halogen lamps Compliance safety and EMC directive
LMET-108
EURO Independent Electronic Transformer
Certificate compliance : EN61347-1:2008; EN61347-2-2:2001+A1+A2; EN55015:2006; EN61547:1995+A1; EN61000-3-2:2006; EN61000-3-3:1995+A1+A2
【23】
Electronic Transformer EURO Independent type
EURO Independent Electronic Transformer Features / Specifications :
Input voltage : 220-240VAC 50/60Hz Output voltage : 11.4VAC Rated loading : 10W ~ 60W Max. ambient temperature Ta = 45ºC Max. case temperature Tc = 75ºC Over heat & over load protection Output short-circuit protect
Soft start & extend use life Output voltage is safety extra low voltage Hi-Pot 4K VAC Fire prevention PC case Fit to all kind of 12V halogen lamps Compliance safety and EMC directive
LMET-109
EURO Independent Electronic Transformer
Certificate compliance : EN61347-1:2008; EN61347-2-2:2001; EN55015:2000+A1+A2; EN61547:1995+A1; EN61000-3-2:2000; EN61000-3-3:1995+A1
LMET-110 EURO Independent Electronic Transformer
Certificate compliance : EN61347-1:2008; EN61347-2-2:2001+A1+A2; EN55015:2006; EN61547:1995+A1; EN61000-3-2:2006; EN61000-3-3:1995+A1+A2
【24】
Electronic Transformer EURO Independent type
EURO Independent Electronic Transformer Features / Specifications :
Input voltage : 220-240VAC 50/60Hz Output voltage : 11.4VAC Rated loading : 35W ~ 110W Max. ambient temperature Ta = 45ºC Max. case temperature Tc = 80ºC Over heat & over load protection Output short-circuit protect
Soft start & extend use life Output voltage is safety extra low voltage Hi-Pot 4K VAC Fire prevention PC case Fit to all kind of 12V halogen lamps Compliance safety and EMC directive
LMET-111
EURO Independent Electronic Transformer
Certificate compliance : EN61347-1:2001; EN61347-2-2:2001; EN55015:2000+A1+A2; EN61547:1995+A1; EN61000-3-2:2000; EN61000-3-3:1995+A1
LMET-112
EURO Independent Electronic Transformer
Certificate compliance : EN61347-1:2001; EN61347-2-2:2001+A1+A2; EN55015:2006; EN61547:1995+A1; EN61000-3-2:2006; EN61000-3-3:1995+A1+A2
【25】
Electronic Transformer EURO Independent type
EURO Independent Electronic Transformer Features / Specifications :
Input voltage : 220-240VAC 50/60Hz Output voltage : 11.4VAC Rated loading : 10W ~ 60W Max. ambient temperature Ta = 45ºC Max. case temperature Tc = 75ºC Over heat & over load protection Output short-circuit protect
Soft start & extend use life Output voltage is safety extra low voltage Hi-Pot 4K VAC Fire prevention PC case Fit to all kind of 12V halogen lamps Compliance safety and EMC directive
LMET-113
EURO Independent Electronic Transformer
Certificate compliance : EN61347-1:2001 EN61347-2-2:2001+A1+A2; EN55015:2006; EN61547:1995+A1; EN61000-3-2:2006; EN61000-3-3:1995+A1+A2
LMET-114
EURO Independent Electronic Transformer
Certificate compliance : EN61347-1:2001; EN61347-2-2:2001+A1+A2; EN55015:2006; EN61547:1995+A1; EN61000-3-2:2006; EN61000-3-3:1995+A1+A2
【26】
Electronic Transformer EURO Independent type
EURO Independent Electronic Transformer Features / Specifications :
Input voltage : 220-240VAC 50/60Hz Output voltage : 11.4VAC Rated loading : 50W ~ 210W Max. ambient temperature Ta = 45ºC Max. case temperature Tc = 80ºC Over heat & over load protection Output short-circuit protect
Soft start & extend use life Output voltage is safety extra low voltage Hi-Pot 4K VAC Fire prevention PC case Fit to all kind of 12V halogen lamps Compliance safety and EMC directive
LMET-115
EURO Independent Electronic Transformer
Certificate compliance : EN61347-1:2001 EN61347-2-2:2001+A1+A2; EN55015:2006; EN61547:1995+A1; EN61000-3-2:2006; EN61000-3-3:1995+A1+A2
LMET-116
EURO Independent Electronic Transformer
Certificate compliance : EN61347-1:2001; EN61347-2-2:2001+A1+A2; EN55015:2006; EN61547:1995+A1; EN61000-3-2:2006; EN61000-3-3:1995+A1+A2
【27】
Electronic Transformer EURO Independent type
EURO Independent Electronic Transformer Features / Specifications :
Input voltage : 220-240VAC 50/60Hz Output voltage : 11.4VAC Rated loading : 50W ~ 250W Max. ambient temperature Ta = 45ºC Max. case temperature Tc = 80ºC Over heat & over load protection Output short-circuit protect
Soft start & extend use life Output voltage is safety extra low voltage Hi-Pot 4K VAC Fire prevention PC case Fit to all kind of 12V halogen lamps Compliance safety and EMC directive
LMET-117
EURO Independent Electronic Transformer
Certificate compliance : EN61347-1:2001 EN61347-2-2:2001+A1+A2; EN55015:2006; EN61547:1995+A1; EN61000-3-2:2006; EN61000-3-3:1995+A1+A2
LMET-118 EURO Independent Electronic Transformer
Certificate compliance : EN61347-1:2001; EN61347-2-2:2001+A1+A2; EN55015:2006; EN61547:1995+A1; EN61000-3-2:2006; EN61000-3-3:1995+A1+A2
【28】
Electronic Transformer EURO Independent type
EURO Independent Electronic Transformer Features / Specifications :
Input voltage : 220-240VAC 50/60Hz Output voltage : 11.4VAC Rated loading : 50W ~ 300W Max. ambient temperature Ta = 45ºC Max. case temperature Tc = 80ºC Over heat & over load protection Output short-circuit protect
Soft start & extend use life Output voltage is safety extra low voltage Hi-Pot 4K VAC Fire prevention PC case Fit to all kind of 12V halogen lamps Compliance safety and EMC directive
LMET-119
EURO Independent Electronic Transformer
Certificate compliance : EN61347-1:2001 EN61347-2-2:2001+A1+A2; EN55015:2006; EN61547:1995+A1; EN61000-3-2:2006; EN61000-3-3:1995+A1+A2
LMET-120
EURO Independent Electronic Transformer
Certificate compliance : EN61347-1:2001; EN61347-2-2:2001+A1+A2; EN55015:2006; EN61547:1995+A1; EN61000-3-2:2006; EN61000-3-3:1995+A1+A2
【29】
Electronic Transformer BS/SAA Plug-in type
BS/SAA Plug-in Electronic Transformer for UK & Australia Features / Specifications :
Input voltage : 220-240VAC 50/60Hz Output voltage : 11.4VAC Rated loading : 10W ~ 60W Max. ambient temperature Ta = 45ºC Max. case temperature Tc = 75ºC Over heat & over load protection Output short-circuit protect
Soft start & extend use life Output voltage is safety extra low voltage Hi-Pot 4K VAC Fire prevention PC case Fit to all kind of 12V halogen lamps Compliance safety and EMC directive
LMET-121
BS Plug-in Electronic Transformer for UK
Certificate compliance : BS EN61347-1:2001 ; BS EN61347-2-2:2001+A1+A2; EN55015:2006; EN61547:1995+A1; EN61000-3-2:2006; EN61000-3-3:1995+A1+A2
LMET-122 SAA Independent Electronic Transformer for Australia
Certificate compliance : AS/NZ61347.1.2:2007; EN55015:2006; EN61547:1995+A1; EN61000-3-2:2006; EN61000-3-3:1995+A1+A2
【30】
Electronic Transformer For North America
Plug-in and Built-in Electronic Transformer for North America Features / Specifications :
Input voltage : 120VAC 50/60Hz Output voltage : 11.4VAC Rated loading : 10W ~ 60W Max. ambient temperature Ta = 45ºC Max. case temperature Tc = 75ºC Over heat & over load protection Output short-circuit protect
Soft start & extend use life Output voltage is safety extra low voltage Hi-Pot 2K VAC Fire prevention PC case Fit to all kind of 12V halogen lamps Compliance safety directive
LMET-123
Plug-in Electronic Transformer for North America
Certificate compliance : UL 1012; CSA-C22.2 NO.107.1
LMET-124 Built-in Electronic Transformer for North America
Certificate compliance : UL 1012; CSA-C22.2 NO.107.1
【31】
Electronic Transformer For North America
Built-in Electronic Transformer for North America Features / Specifications :
Input voltage : 120VAC 50/60Hz Output voltage : 11.4VAC Rated loading : 10W ~ 60W Max. ambient temperature Ta = 45ºC Max. case temperature Tc = 75ºC Over heat & over load protection Output short-circuit protect
Soft start & extend use life Output voltage is safety extra low voltage Hi-Pot 2K VAC Fire prevention PC case Fit to all kind of 12V halogen lamps Compliance safety directive
LMET-125
Built-in Electronic Transformer for North America
Certificate compliance : UL 1012; CSA-C22.2 NO.107.1
LMET-126
Built-in Electronic Transformer for North America
Certificate compliance : UL 1012; CSA-C22.2 NO.107.1
【32】
Electronic Transformer For North America
Plug-in and Built-in Electronic Transformer for North America Features / Specifications :
Input voltage : 120VAC 50/60Hz Output voltage : 11.4VAC Rated loading : 35W ~ 105W / 50W ~ 150W Max. ambient temperature Ta = 45ºC Max. case temperature Tc = 80ºC / 90ºC Over heat & over load protection Output short-circuit protect
Soft start & extend use life Output voltage is safety extra low voltage Hi-Pot 2K VAC Fire prevention PC case Fit to all kind of 12V halogen lamps Compliance safety directive
LMET-127 (35W ~ 105W) / LMET-128 (50W ~ 150W)Plug-in Electronic Transformer for North America
Certificate compliance : UL 1012; CSA-C22.2 NO.107.1
LMET-129
Built-in Electronic Transformer for North America
Certificate compliance : UL 1012; CSA-C22.2 NO.107.1
【33】