Electronic Overload RelaysElectronic Overload Relays
EOCR
ISO 9001 : 2008
NABCBQ M 0 3 0
U®
CONCORD has been the pioneer of the Electronic Motor Protection technology in the Indian market with innovative and useful products for the
Industry since 1997. We design build and supply a vast array of Electronic Protection Relays and our vision is to become the best supplier for Motor
protection and Motor management for its customers nationwide.
Electronic Overload Relays
Salient Features
�
�
�
�
Compact Design
2/3 Integral Current Transformers
Multiple Protection Features
Wide Current Adjustment Range
�
�
�
�
�
Ammeter Function
Trip Indication/ Fault Diagnosis
Highly Accurate
Looping Options
Manual/ Electrical Remote Reset
EOCREOCR
�
�
�
�
Test Function
Suitable for use with External CT’s upto 600A
Ambient Insensitive
Low Energy Consumption
D-Time (Starting delay Time)
O-Time (Operating Time)
The D-Time is the time taken by the motor before it reaches it’s normal
running current. During start the motor draws much higher levels of
current and the D-Time setting is to ensure that the EOCR does not
cause any nuiscance trippings before this set time has elapsed. After the
D-Time setting is over the relay monitors the normal running currents.
Full Load Current
Set Current
TRIP
D-Time
Normal Load
O-Time
CURRENT
TIM
E
O-Time is the operating time in the event of overload. When motor
current exceeds the desired set current value, the EOCR detects the
increase and trips the motor within the set O-Time preventing excess
heating and long periods of overload.
The TEST function facility on the front face of the relay is provided to
check the health status of the relay without electrically nergizing the
relay. On pressing the TEST button the internal relay will trip after the D-
Time + O-Time settings have elapsed. After using this test facility , the
RESET button has to be pressed to operate the relay
By pressing the RESET button or disconnecting the electrical supply
will trip the relay immediately. Once the relay has tripped due to any
Over Load or any other fault, the relay has to be reset to start the
motor again.
Reset Function
TEST RESET
Looping Option
The Looping option is required in case the amount of current
measurement is desired to be more accurate and precise. The wire from
the main line when passing through the Internal EOCR CT is looped one
or more times depending upon the current range of the relay to suit the
application.
External CT Option
By using External CT’s with secondary rating of 5A the EOCR can be
used to monitor and protect motors with normal running currents of
upto 600A. This is used with an 05 Type relay with current setting range
of 0.5 - 6A. In Digital models the display current values are selectable as
desired.
[A] 1x
0,5-6
2,5-30
5-60
-05
-30
-60
2x
0,25-6
1,25-15
2,5-30
0,17-2
0,83-10
1,7-20
3x
0,13-1,5
0,62-7,5
1,25-15
4x 5x
0,1-1,2
0,5-6
1-12
Test Function
CONCORD
Wiring Diagram
Overall Dimesnions
MC
Tr.
L1L2
9596
98
EOCR SS
M
MC ON
OFF/RESET
L1 L2 L3
10
54
54
65
4416
5 - M3.58.4DIN RAIL TYPE
L1L2
9596
9798 N
R
M
EOCR DS3
MC
MC
Tr.
OFF/RESET
ON
Overall DImensions
58 39
4612
1076-M3.5
69
81
L1 L2 L3
Fuse Tr.
MC MC
MC
ON
OFF(RESET)
A1A295969798
M EOCR SSD N TYPE
Overall DImensions
8 8 8 8 CONCORD
12
6-M3.5
50.8
19.5
58
51
62.2
10
77.2
Features
3 Integral Current Transformers
Independently adjustable D-Time and O-Time
Independent Mounting
Run Monitor and Fault Diagnosis with 2 LED’s
Protection Functions
Overcurrent
Phase Loss
Locked Rotor
Phase Reverse
O-Time
Within 4 seconds
Within D-Time
0.1sec
Specifications
Current Setting
Time Setting
Control Voltage
Contact Rating
Time CurrentCharacteristicOperating(Trip Indication
Mounting
Type053060100A and aboveStart(D-Time
Trip (O-Time)Control Voltage
Contact RatingRating(R)Status
Definite
2 LED with Fault Diagnosis
35mm DIN Rail/Base
Range0.5-6A3-30A5-60AWith External CT1 - 50sec
0.2-10sec180-260VAC
1SPDT(1C)3A 250VACNormallyEnergized
Protection Functions
Over current
Phase Loss
Locked Rotor
O-Time
Within 4 sec
0.5 sec after D Time
has elapsed
Features
2 CT based Digital Protection Relay
Current Display of Max. current in any phase
Highly accurate protection for Locked Rotor
Compact Size and Ambient Insensitive
Indepebdent settings for D-Time and O-Time
Specifications
Current Setting
Starting Delay Time 1-30 sec
(D-Time)
Operating Time 1-10 sec
(O-Time)
Reset Manual/Remote
Overcurrent Trip Definite
Control Voltage 110V AC/220V AC
Contact Rating 2SPST 3A/250V AC Resistive
Fault Diagnosis 7 Segment LED Display
Mounting 35mm DIN Rail/Base
05 0.5-6A30 3-30A60 5-60A
Overcurrent O-Time
Phase Loss O-Time
Locked Rotor O-Time + D-Time
Protection Functions
Features
Specifications
Current Setting
Time Setting
Control Voltage
Contact Rating
Time Current
Characteristic
Operating
(Trip Indication)
Mounting
Type
05
30
60
100A and above
Start(D-Time
Trip (O-Time)
220
440
Mode
Rating(R)
Status
Definite
2 LED
35mm DIN Rail/Base
Range
0.5-6A
3-30A
5-60A
With External CT
0.2-30sec
0.2-10sec
90-260VAC
320-480VAC
1SPDT(1C)
3A 250VAC
Normally
Energized
EOCR SSDEOCR DS EOCR SS
Wiring Diagram Wiring Diagram
SOLID STATE MCU BASED DIGITAL
2 Integral Current Transformer’s
Electronic Shear Pin Function
Independently Adjustable D-Time and O-Time
Independent Mounting
L3L2L1
Available in your area with:
For More details/information, please contact:CONCORD AUTOMATION & CONTROLS
G 43, DLF Industrial Estate, 1 Faridabad
121003 Haryana (INDIA)
Phone :
Mobile :
Fax :
0129 2278256, 2273860
+91 9810659379
0129 2278350
Email :
Website : http://www.cacindia.net
CONCORDWiring Diagram
Overall DImensions
Trip Characteristic
L1 L2 L3
FUSE Tr.*
MC
EOC
R 3
DE
M
RESETOFF MC
MCON
ALERTTRIP
R GMCSTOP
EOCR-3DE
A1
A2
96 98
95 97 07
08
OL/UL
AL/UL
A1
A2
95
96
97
98
07
08
EOCR 3DE EOCR 3EZ
EO
CR 3
EZ
A1
A2
Z1Z2
97
98
57
58
L1 L2 L3
FUSE Tr.
MC Aux
MC RESET OFF
MC
MCON
R G Y
Stop Run
Aux
AuxTrip/GR
GROL/ULEOCR-3EZ
A1
A2
Z1
Z2 97
98 58
57
M
Z2(k)
Z1(k)
~
70
10
16
53
DIN RAIL TYPE
71 59
15
7.5
55
10 10
20 20
30 30
0.1
1
1 2 4 6 8 10
10
100
1000
10000TIME (sec)
CURRENTMultiples of Current Setting
HOT
COLDTIME ( sec)
Ad
just
able
CurrentMultiples of Current Setting
0.21
0 1 2 3 4 5 6
30
Inverse Type - EOCR 3DE/EZ Definite Type - EOCR SS/SSD/DS
Protection Functions
Protection
Overcurren
Undercurrent
Phase Loss
Phase Unbalance
Phase Reverse
Locked Rotor
Ground Fault
3DE Trip Time
O-Time
0.5-30 sec
3 sec
8 sec
0.1-0.3 sec
D-Time
NA
Trip Time
3EZ
O-Time
0.5-30 sec
3 sec
8 sec
0.1-0.3 sec
D-Time
0.05-10 sec
Features
MCU Based Design
3 Integral Current Transformers
Multiple Protection Features
Digital Ammeter and Fault Diagnosis
Wide Current Adjustment range
User selectable Time Current curves - Definite/Inverse
Manual/Remote reset
Ambient Insensitive
Alert Function before trip
Specifications
Current Setting
Above 60A
Ground Fault setting
Alert Setting
Start Delay Tim
(D-Time)
Trip Delay Time
(O-Time)
Control Voltage
Contact Rating
Trip Time
Characteristic
Fault Diagnosis
Mounting
3DE
05/60A
With Suitable External CT
NA
5-100%/OFF
1-200 sec
INV
DEF
110VAC/220VAC
2 SPST 3A/250V Resistive
INV/DEF- Refer to Graph
7 segment LED Display
35mm DIN Rail/Base
3EZ
05/60A
A:0.02-3A, B:0.2-10A
NA
1-30 sec
0.2-30 sec
EOCR 3DE / 3EZ
DIGITAL
*We reserve the right to change specification without notice