Electrical Plans *Generally most of the outlets in the home are 120 volts duplex outlets. Duplex outlets have two receptacles. *Duplex outlets are placed 12” above the floor *220 volt outlets are used for double ovens, furnace, electric water heater, clothes dryer, spa, and welders

Page 3: Electrical Plans - rhs-cte-technology.weebly.comrhs-cte-technology.weebly.com/uploads/8/5/3/0/8530838/electrical_p… · Electrical Plans *Kitchen, bathroom, laundry, outdoor circuits,

Electrical Plans In habitable rooms, duplex outlets should be placed a maximum of 12 feet apart along the wall line.

Duplex outlets should be no more than 6' from an opening.

Each wall over 2' in length must have an outlet.

Think of furniture placement so duplex outlets do not become inaccessible behind large pieces of furniture. Place a duplex outlet next to or behind a desk or table where light is needed.

Page 4: Electrical Plans - rhs-cte-technology.weebly.comrhs-cte-technology.weebly.com/uploads/8/5/3/0/8530838/electrical_p… · Electrical Plans *Kitchen, bathroom, laundry, outdoor circuits,

Electrical Plans Place a duplex outlet near a fireplace, for an adjacent table light, a vacuum, or for fireplace maintenance. Place a duplex outlet in a hallway, for a vacuum.

Page 5: Electrical Plans - rhs-cte-technology.weebly.comrhs-cte-technology.weebly.com/uploads/8/5/3/0/8530838/electrical_p… · Electrical Plans *Kitchen, bathroom, laundry, outdoor circuits,

Electrical Plans *Special purpose outlets are used as electrical outlets for appliances such as dishwashers and garbage disposals. Smoke detectors are also attached to special purpose outlets.

Page 6: Electrical Plans - rhs-cte-technology.weebly.comrhs-cte-technology.weebly.com/uploads/8/5/3/0/8530838/electrical_p… · Electrical Plans *Kitchen, bathroom, laundry, outdoor circuits,

Electrical Plans Each vanity and dressing table should have at least one duplex outlet.

Page 7: Electrical Plans - rhs-cte-technology.weebly.comrhs-cte-technology.weebly.com/uploads/8/5/3/0/8530838/electrical_p… · Electrical Plans *Kitchen, bathroom, laundry, outdoor circuits,

Electrical Plans Duplex outlets over kitchen counters should be placed no further than 4 feet apart.

Page 8: Electrical Plans - rhs-cte-technology.weebly.comrhs-cte-technology.weebly.com/uploads/8/5/3/0/8530838/electrical_p… · Electrical Plans *Kitchen, bathroom, laundry, outdoor circuits,

Electrical Plans *Kitchen, bathroom, laundry, outdoor circuits, and garages or outbuildings are required to be protected by a GFCI outlet *Ground Fault Circuit Interrupter (GFCI or GFI), which trips a circuit breaker when there is any unbalance in the circuit current. Outside duplex outlets should be placed at a convenient exterior location, such as a patio.

Page 9: Electrical Plans - rhs-cte-technology.weebly.comrhs-cte-technology.weebly.com/uploads/8/5/3/0/8530838/electrical_p… · Electrical Plans *Kitchen, bathroom, laundry, outdoor circuits,

Electrical Plans *All exterior outlets must be waterproof and GFCI. The letters WP are used to identify the cover plate on exterior duplex outlets.

Page 10: Electrical Plans - rhs-cte-technology.weebly.comrhs-cte-technology.weebly.com/uploads/8/5/3/0/8530838/electrical_p… · Electrical Plans *Kitchen, bathroom, laundry, outdoor circuits,

Electrical Plans Bathroom lights are commonly placed over the vanity.

Page 11: Electrical Plans - rhs-cte-technology.weebly.comrhs-cte-technology.weebly.com/uploads/8/5/3/0/8530838/electrical_p… · Electrical Plans *Kitchen, bathroom, laundry, outdoor circuits,

Electrical Plans To prevent insulation compression in exterior walls electrical wiring may be placed at the bottom of the stud on the sole plate.

Page 12: Electrical Plans - rhs-cte-technology.weebly.comrhs-cte-technology.weebly.com/uploads/8/5/3/0/8530838/electrical_p… · Electrical Plans *Kitchen, bathroom, laundry, outdoor circuits,

Electrical Plans Each enclosed bath or laundry should have an exhaust fan or an openable window

Page 13: Electrical Plans - rhs-cte-technology.weebly.comrhs-cte-technology.weebly.com/uploads/8/5/3/0/8530838/electrical_p… · Electrical Plans *Kitchen, bathroom, laundry, outdoor circuits,

Electrical Plans Carefully caulk and seal around all light and convenience outlets. Also, caulk and seal where electrical wires penetrate the top and bottom plates.

Page 14: Electrical Plans - rhs-cte-technology.weebly.comrhs-cte-technology.weebly.com/uploads/8/5/3/0/8530838/electrical_p… · Electrical Plans *Kitchen, bathroom, laundry, outdoor circuits,

Electrical Plans When lighting a stairway you should place a switch at each level.

Page 15: Electrical Plans - rhs-cte-technology.weebly.comrhs-cte-technology.weebly.com/uploads/8/5/3/0/8530838/electrical_p… · Electrical Plans *Kitchen, bathroom, laundry, outdoor circuits,

Electrical Plans Place exterior lights properly to illuminate walks, drives, patios, decks, and other high-use areas.

Page 16: Electrical Plans - rhs-cte-technology.weebly.comrhs-cte-technology.weebly.com/uploads/8/5/3/0/8530838/electrical_p… · Electrical Plans *Kitchen, bathroom, laundry, outdoor circuits,

Electrical Plans In areas that require high illumination you could use fluorescent lighting fixtures.

Page 17: Electrical Plans - rhs-cte-technology.weebly.comrhs-cte-technology.weebly.com/uploads/8/5/3/0/8530838/electrical_p… · Electrical Plans *Kitchen, bathroom, laundry, outdoor circuits,

Electrical Plans Electrical light and receptacle symbols should be drawn with an 1/8 inch diameter circle.

Page 18: Electrical Plans - rhs-cte-technology.weebly.comrhs-cte-technology.weebly.com/uploads/8/5/3/0/8530838/electrical_p… · Electrical Plans *Kitchen, bathroom, laundry, outdoor circuits,

Electrical Plans Switch symbols are drawn perpendicular to the wall to be read from the bottom or right of the sheet.

Page 19: Electrical Plans - rhs-cte-technology.weebly.comrhs-cte-technology.weebly.com/uploads/8/5/3/0/8530838/electrical_p… · Electrical Plans *Kitchen, bathroom, laundry, outdoor circuits,

Electrical Plans A single-pole switch may be connected to one or more lights.

*A three-way switch controls one or more lights from two switches.

A four-way switch controls one or more lights from three or more switches

Page 20: Electrical Plans - rhs-cte-technology.weebly.comrhs-cte-technology.weebly.com/uploads/8/5/3/0/8530838/electrical_p… · Electrical Plans *Kitchen, bathroom, laundry, outdoor circuits,

Electrical Plans

Page 21: Electrical Plans - rhs-cte-technology.weebly.comrhs-cte-technology.weebly.com/uploads/8/5/3/0/8530838/electrical_p… · Electrical Plans *Kitchen, bathroom, laundry, outdoor circuits,

Electrical Plans The meter base must always be mounted so the meter socket is on the exterior of the house, preferable on the side wall of a garage. The meter base should not be installed on the front of the house for aesthetic reasons.

Page 22: Electrical Plans - rhs-cte-technology.weebly.comrhs-cte-technology.weebly.com/uploads/8/5/3/0/8530838/electrical_p… · Electrical Plans *Kitchen, bathroom, laundry, outdoor circuits,

Electrical Plans The preferred location for the distribution panel is on an inside garage wall, close to the heaviest electrical loads, such as a range, clothes dryer, or electric furnace If the house does not have garage, the panel should be located in a readily accessible area such as a utility room or kitchen wall.

Page 23: Electrical Plans - rhs-cte-technology.weebly.comrhs-cte-technology.weebly.com/uploads/8/5/3/0/8530838/electrical_p… · Electrical Plans *Kitchen, bathroom, laundry, outdoor circuits,

Electrical Plans

On an underground service the lines should be placed a minimum of 24 inches below grade.

Page 24: Electrical Plans - rhs-cte-technology.weebly.comrhs-cte-technology.weebly.com/uploads/8/5/3/0/8530838/electrical_p… · Electrical Plans *Kitchen, bathroom, laundry, outdoor circuits,

Matching

Thermostat

Smoke Detector

Fan

Fluorescent Light

220 Volt Outlet

Recessed Power Center

Wall Mounted Lighting Outlet

Weatherproof Receptacle

4 Way Switch

Page 25: Electrical Plans - rhs-cte-technology.weebly.comrhs-cte-technology.weebly.com/uploads/8/5/3/0/8530838/electrical_p… · Electrical Plans *Kitchen, bathroom, laundry, outdoor circuits,

Matching

Motor

Electrical Door Opener

Ground Fault Circuit Interrupt

Single Pole Switch

Telephone

Overhead Lighting Outlet

Dishwasher Outlet

Cable TV Outlet

Buzzer

Generator

Chimes

Split Wired Outlet