12
CERTIFIED UNDERFLOOR HEATING WITH 15 YEARS’ GUARANTEE Electric underfloor heating Simple to install Cheap to install Simple to regulate Safe to use Maintenance free

Electric underfloor heating • Simple to install • Cheap to install • … · 2020-01-21 · Electric underfloor heating • Simple to install • Cheap to install • Simple

  • Upload
    others

  • View
    8

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Electric underfloor heating • Simple to install • Cheap to install • … · 2020-01-21 · Electric underfloor heating • Simple to install • Cheap to install • Simple

CERTIFIED UNDERFLOOR HEATING WITH 15 YEARS’ GUARANTEE

Electric underfloor heating• Simpletoinstall• Cheaptoinstall• Simpletoregulate• Safetouse• Maintenancefree

Page 2: Electric underfloor heating • Simple to install • Cheap to install • … · 2020-01-21 · Electric underfloor heating • Simple to install • Cheap to install • Simple

Correct choice of underfloor heating Heatcomheatingcablesforalltypesoffloors.Heatingcablescanbeusedundertiles,slate,stone,laminate,parquet,orembeddedinthefloor.

Heatingcablesareprobablythemosteffectivemethodofheatingaroom.Theheatisemittedovertheentirefloorarea,considerablyimprovingtheindoorclimate.Thefloortemperaturecanbeset2-3oClowerthanthedesiredroomtemperature.Thiscangenerateenergysavingsof10-15%.Useofanefficientthermostatcanreducetheenergyconsumptionevenfurther,i.e.upto25%.

Power output (watt/m2) under tiles, slate, and similar

ItisimportanttolaythecablesinsuchawaythattheycanrespondquicklytotemperaturechangesDependingonwhattheroomistobeusedforandhowthefloorisinsulated,100-150W/sq.mwillbesufficient.

WHY CHOOSE HEATCOM?

Heatcom is a leading Danish manufacturer of under-floor heating. We have more than 20 years’ experience from production of electric underfloor heating, and our products meet the highest quality requirements.

Quality tested by Semko, VDE, and BEAB, Heatcom heating cables satisfy all requirements stipulated in the EN 60335-2-96 standard.

Heatcom therefore provides a 15-year warranty with its heating cables.

1

Page 3: Electric underfloor heating • Simple to install • Cheap to install • … · 2020-01-21 · Electric underfloor heating • Simple to install • Cheap to install • Simple

Save up to 25% energy with low profile floor heating.

HEATCOM UNDERFLOOR HEATING FOR HOUSE AND HOME

TheHeatcomcablematissuitableforrectangularrooms.Simpleandfasttolay,itonlyraisesthefloorheightby5mm.Thematisplacedinflexibleprimerortileadhesive,andthecablemustbecompletelycovered.

Toavoidcracksanddamage,thesurfacemustbestable.

SelectionofWatt/sq.mdependsonhowwellthefloorisinsulated.LayingHeatcomcablematsissimple.

Thecablematismountedonadust-freesurfaceusingstrongdouble-sidedtape.Thecalculatedheatingcableareamustbeequivalenttoabout80%oftheroom’stotalarea.IncombinationwiththeHeatcomprogrammablethermostat,thisisaneffectivewaytosaveenergy.

2

3mm cable mat

3mm cable mat 100W/m2, width 50cm

Itemno. Description Powerwatt Lengthm Sq.m

32100150 HeatingMat100W/m²-1,1m²(0,5x2,1m) 110W 2,1 1

32101550 HeatingMat100W/m²-1,4m²(0,5x3,0m) 150W 3 1,4

32100250 HeatingMat100W/m²-2,0m²(0,5x4,0m) 200W 4 2

32100350 HeatingMat100W/m²-3,0m²(0,5x6,20m) 320W 6,2 3,0

32100450 HeatingMat100W/m²-4,1m²(0,5x8,20m) 410W 8,2 4,1

32100550 HeatingMat100W/m²-4,9m²(0,5x9,80m) 490W 9,8 4,9

32100650 HeatingMat100W/m²-5,8m²(0,5x11,60m) 580W 11,6 5,8

32100700 HeatingMat100W/m²-7,0m²(0,5x14,0m) 700W 14 7

32100850 HeatingMat100W/m²-8,3m²(0,5x16,65m) 830W 16,65 8,3

32100900 HeatingMat100W/m²-9,0m²(0,5x18,0m) 940W 18 9

32101050 HeatingMat100W/m²-10,2m²(0,5x20,60m) 1020W 20,4 10,2

3mm cable mat 150W/m2. width 50cm

Itemno Description Powerwatt Lengthm Sq.m

32150150 HeatingMat150W/m²-1,1m²(0,5x2,20m) 165W 2,2 1,1

32151550 HeatingMat150W/m²-1,5m²(0,5x3,0m) 225W 3 1,5

32150250 HeatingMat150W/m²-2,0m²(0,5x4,05m) 300W 4,05 2

32150230 HeatingMat150W/m²-2,3m²(0,5x4,60m) 350W 4,6 2,3

32150280 HeatingMat150W/m²-2,8m²(0,5x5,50m) 420W 5,5 2,8

32150350 HeatingMat150W/m²-3,1m²(0,5x6,20m) 465W 6,2 3,1

32150450 HeatingMat150W/m²-3,7m²(0,5x7,40m) 555W 7,4 3,7

32150470 HeatingMat150W/m²-4,4m²(0,5x8,80m) 660W 8,8 4,4

32150550 HeatingMat150W/m²-5,2m²(0,5x10,20m) 785W 10,2 5,2

32150650 HeatingMat150W/m²-6,2m²(0,5x12,40m) 955W 12,4 6,2

32150680 HeatingMat150W/m²-6,8m²(0,5x13,60m) 1020W 13,6 6,8

32150850 HeatingMat150W/m²-7,7m²(0,5x15,35m) 1070W 15,35 7,7

32150890 HeatingMat150W/m²-8,7m²(0,5x17,40m) 1320W 17,4 8,7

32151050 HeatingMat150W/m²-10,4m²(0,5x20,80m) 1560W 20,8 10,4

Page 4: Electric underfloor heating • Simple to install • Cheap to install • … · 2020-01-21 · Electric underfloor heating • Simple to install • Cheap to install • Simple

3

Supplied with a “two-in-one” programmable thermostat and installation tape.

Heatcom 3 mm heating cable on drum. 12 W/running metre

Heatcom 3mm heating cable on drum 12W/running metre. with HC 11 TP digital programmable thermostat

Itemno. Description Lengthm Watt.total 100watt/m2=cc12cm 150watt/m2=cc8cm Ohm

38160130 Kit130HC11TP 11,3 130 1,3m2 0,9m2 407

38160200 Kit200HC11TP 16,5 200 2,0m2 1,3m2 264

38160290 Kit290HC11TP 23,5 290 2,9m2 1,9m2 183

38160420 Kit420HC11TP 36,0 420 4,2m2 2,9m2 126

38160490 Kit490HC11TP 39,0 490 4,9m2 3,1m2 109

38160580 Kit580HC11TP 47,0 580 5,8m2 3,8m2 92

38160670 Kit670HC11TP 57,0 670 6,7m2 4,6m2 80

38160800 Kit800HC11TP 68,0 800 8,0m2 5,4m2 67

38160960 Kit960HC11TP 79,0 960 9,6m2 6,3m2 55

38161050 Kit1050HC11TP 87,0 1050 10,5m2 7,0m2 50

38161190 Kit1190HC11TP 99,0 1190 11,9m2 7,9m2 44

38161340 Kit1340HC11TP 112,0 1340 13,4m2 9,0m2 40

38161600 Kit1600HC11TP 133,0 1600 16m2 10,6m2 33

38161740 Kit1740HC11TP 145,0 1740 17,4m2 11,6m2 31

38162000 Kit2000HC11TP 166,0 2000 20,0m2 13,3m2 27

38162140 Kit2140HC11TP 177,0 2140 21,4m2 14,1m2 25

Heatcomheatingcableondrumisrecommendedforareasthatarenotrectangularandinwhichpermanentfixturesmakeitdifficulttolayamat.Heatcomheatingcableondrumissuppliedasasetthatincludesdouble-sidedinstallationtapeandaprogrammablethermostat.Thecableisaffixedtothesurfaceusingthestrongdouble-sidedtape,andonlyraisesthefloorby5mm.Heatcomlowprofilecableislaidinflexibleprimerordirectlyintileadhesive.Itmustbecompletelycoveredbytheadhesiveorprimer.Bothproductsmustbeintendedforusewithfloorheating.Thepoweroutputpersq.mcanbeadjustedbyvaryingthedistance(ccdistance)betweeneachcablelength.Pleaseseethetablebelow.

Heatcomheatingcableissuppliedwithaunique“two-in-one”programmablethermostat.Thethermostathasbothmanualandprogrammableoptions,andyoucandecidewhichtouseafterinstallation.BycombiningtheHeatcomlow-profileheatingcablewithaHeatcomprogrammablethermostatyoucansaveupto25%energy.TheHeatcomprogrammablethermostatmeetsNorwegianrequirementsforinstallationinbathroomsandwetrooms.

NB!Squareareaminus20%givesthecorrectsquareareaofheatingcable.

Page 5: Electric underfloor heating • Simple to install • Cheap to install • … · 2020-01-21 · Electric underfloor heating • Simple to install • Cheap to install • Simple

Heatcom Strong 18W/running metre. 5.5mm heating cable

Heatcom 5.5mm reinforced heating cable 18W/running metre for laying in screed

Itemno. Description Watt Length Ohm

51210110 HeatingCable5,5mmSTRONG-11,0m 200W 11,0m 262

51210165 HeatingCable5,5mmSTRONG-16,5m 300W 16,5m 174

51210220 HeatingCable5,5mmSTRONG-22,0m 400W 22,0m 131

51210275 HeatingCable5,5mmSTRONG-27,5m 500W 27,5m 105

51210330 HeatingCable5,5mmSTRONG-33,0m 600W 33,0m 87

51210390 HeatingCable5,5mmSTRONG-39,0m 700W 39,0m 76

51210460 HeatingCable5,5mmSTRONG-46,0m 850W 46,0m 62

51210550 HeatingCable5,5mmSTRONG-55,0m 1000W 55,0m 52

51210690 HeatingCable5,5mmSTRONG-69,0m 1250W 69,0m 42

51210760 HeatingCable5,5mmSTRONG-76,0m 1375W 76,0m 38

51210940 HeatingCable5,5mmSTRONG-94,0m 1700W 94,0m 31

51211160 HeatingCable5,5mmSTRONG-116,0m 2100W 116,0m 25

51211440 HeatingCable5,5mmSTRONG-144,0m 2600W 144,0m 20

51211830 HeatingCable5,5mmSTRONG-183,0m 3300W 183,0m 16

34000025 HTCUFixingtape25m -

Supplied on a drum. thermostat not included.Heatcom Strong 18 cable. 18W/running meter is intended for laying in screed and is a reinforced class C cable with a specially robust PVC outer jacket.

HeatcomStrong18isaparticularlyrobustheatingcablethatcanbeinstalledonreinforcingsteelornets.Ifthecableistobelaidinso-calledground-moistconcrete.Particularcaremustbetakentoavoidformationofairpocketsaroundthecable.andthattheconcretehasadequatethermalconductivity.Pleaserefertotheregulations.

HeatcomStrong18canalsobeinstalledonafirmsurface.andinthiscaseHTCUfixingtapeisused.Thenumberofwattspersq.misdeterminedbythespacingbetweenthecables.HeatcomStrong18isalsosuitableforconcretedoutdoorsurfacesandcanbecombinedwiththeHeatcomprogrammablethermostatHC11TP.

4

Page 6: Electric underfloor heating • Simple to install • Cheap to install • … · 2020-01-21 · Electric underfloor heating • Simple to install • Cheap to install • Simple

Heatcom AluMat floor heating for laminate and parquet 80 Watt/m2

AluMat for laminate and parquet - 80 W/m2

Itemno. Description Watt

40840010 AluMat-0,5x2,0m-1,0m² 80W

40840015 AluMat-0,5x3,0m-1,5m² 120W

40840020 AluMat-0,5x4,0m-2,0m² 160W

40840025 AluMat-0,5x5,0m-2,5m² 200W

40840030 AluMat-0,5x6,0m-3,0m² 240W

40840035 AluMat-0,5x7,0m-3,5m² 280W

40840040 AluMat-0,5x8,0m-4,0m² 320W

40840045 AluMat-0,5x9,0m-4,5m² 360W

40840050 AluMat-0,5x10,0m-5,0m² 400W

40840060 AluMat-0,5x12,0m-6,0m² 480W

40840070 AluMat-0,5x14,0m-7,0m² 560W

40840080 AluMat-0,5x16,0m-8,0m² 640W

40840090 AluMat-0,5x18,0m-9,0m² 720W

40840100 AluMat-0,5x20,0m-10,0m² 800W

Heatcom Alumat. glass-fibre reinforced aluminium foil with earthed heating cable. Approved by Semko.

AluMatgivesafloorriseofonly2-3mmandcanbelaiddirectlybelowlaminateorparquet.WerecommendlayingAluMatona3mmHeatcomreflectorplate.Withapoweroutputof80watt/sq.m.itcanbeusedastheprimaryheatingsourceintheroom.Inolderhouses.heatlosscanbearound50-55Watt/sq.m.Apoweroutputlowerthan70-80W/m2mayresultininadequateheating,andsupplementaryheatingmaybenecessary.Toensuregoodheatradiationwithoutdamagetothewoodfloor.parquetmanufacturers’recommendthatthefloortemperatureshouldnotexceed+27oC.Ahighertemperaturecoulddamagetheparquet.Itisthereforearequirementthatunderfloorheatingforawoodfloorisconnectedtoathermostatwithmaximumtemperaturelimitedto27oC.TheHeatcomthermostattypeHC11TPhasanintegraltemperaturerestrictorof+27oCandcanthereforeberecommendedforusewithunderfloorheatingforwoodenfloors.

Thermalblockingmayoccurunderwoodenfloorsi.e.theheatcollectsunderthickcarpetsorfurniturethatrestsdirectlyonthesurface.Thisisunfortunateandcoulddamagethefloor.Athermostatcannotpreventthermalblocking.

5

Page 7: Electric underfloor heating • Simple to install • Cheap to install • … · 2020-01-21 · Electric underfloor heating • Simple to install • Cheap to install • Simple

Heatcom thermostats with double pole breaker and IP 21

Thermostats for underfloor heating

Itemno. Description.SuppliedasstandardwithElkoframe.OptionsEljo.BJ. Watt

53100018 HeatcontrolHC11TPProgrammablewithfloorandroomsensor.doublepoleIP21-16A 3600W

53100019 HeatcontrolHC11TPMDigitalmanualon/offwithfloorsensor.doublepoleIP21-16A 3600W

53300600 DINmountedthermostatformountinginafusebox.ETV-1991 3600W

53400041 HC41manualthermostatwithcover 3600W

HeatcomthermostatshavebeenspecificallydevelopedfortheNordicmarket.HC11TPandHC11TPMsatisfyallrequirementsforinstallationinbathroomsandwetrooms.ThethermostatsarethereforeequippedwithadoublepolebreakerandprotectionagainstcondensationequivalenttoIP21.Refertotherequirementsintheregulations.

UseofHeatcom3mmreflectorplatesincreasesthelevelofinsulationandconsiderablyreducesthenoisefromfootsteps.Heatcomreflectorplateshavegoodcompressivestrength.andaresuitableasacomponentoftheunder-tilesurface.Thecablesmustbecoveredcompletelybyflexibleprimeroradhesive.Whenusingreflectorplates.itisrecommendedthattheheatingcablesareplacedinaself-supportingreinforcedscreedorflexibleprimerwithathicknessofatleast25-30mm.Theunderlyingsurfacemustalsobestabletopreventcracksoccurringinjoinsortiles.

Reflectorplatesaresuppliedeitheraswholeplates0.5x1.2m.orafolded“harmonica”pack1.22x8.33m=10m2

Heatcom reflector plates.Increases the level of insulation in the floor and reduces the noise from footsteps.

Reflector plates

Itemno. Description

40101030 Reflectorplate3mm500x1200–pack6m2

40101060 Reflectorplate6mm500x1200–pack6m2

40101045 ReflectorHCEasy.3mm.foldedplatethatcovers1.22x8.33=10m2

Approved for installation in bathrooms and wet rooms.

HC 11 TP HC 11TPM HC 41 Programmable Manual/digital Manual with cover

6

“two-in

-one”

Page 8: Electric underfloor heating • Simple to install • Cheap to install • … · 2020-01-21 · Electric underfloor heating • Simple to install • Cheap to install • Simple

Heatcom heating cables for outdoor and indoor pipe protection

Frost Guard with thermostat for external frost protec-tion of pipes - 13W/running metre

Itemno. Designation Watt

43000014 FrostGuardwiththermostat-1,4m 19W

43000020 FrostGuardwiththermostat-2m 26W

43000040 FrostGuardwiththermostat-4m 53W

43000080 FrostGuardwiththermostat-8m 107W

43000105 FrostGuardwiththermostat-10,5m 140W

43000140 FrostGuardwiththermostat-14m 185W

43000185 FrostGuardwiththermostat-18,5m 246W

43000225 FrostGuardmedtermostat-22,5m 300W

Thecoldendisplacedclosetoanearthedsocketandtheheatingcableislaidalongsideorwoundaroundthepipe.

Heatcom mirror heater for demisting mirrors

Speilvarme for duggfrie speil

Itemno. Description Watt

40304045 Dimensions-40x45cm 70W

40307657 Dimensions-76x57cm 100W

40311060 Dimensions-110x60cm 144W

Self-adhesivemirrorheaterthatcanbegluedtotherearofthemirror.Preventscondensation.

Iftheareaaroundamirrorwithheateristobetiled.roommustbeallowedforpossibleexpansionofthemirrori.e.thetilesmustnotbeplacedcompletelyadjacenttothemirror.

Themirrorheaterisconnectedtothesamecircuitasthelights.

7

Self-limiting heating cable for frost protection of internal or external pipes

Itemno. Designation Watt

40047002 Pipeheat2,0mCableforinternalinstallationinpipes 22W

40047004 Pipeheat4,0mCableforinternalinstallationinpipes 44W

40047006 Pipeheat6,0mCableforinternalinstallationinpipes 66W

40047008 Pipeheat8,0mCableforinternalinstallationinpipes 88W

40047010 Pipeheat10,0mCableforinternalinstallationinpipes 110W

40047012 Pipeheat12,0mCableforinternalinstallationinpipes 132W

40047014 Pipeheat14,0mCableforinternalinstallationinpipes 154W

40047016 Pipeheat16,0mCableforinternalinstallationinpipes 176W

40047019 Pipeheat19,0mCableforinternalinstallationinpipes 209W

40047022 Pipeheat22,0mCableforinternalinstallationinpipes 242W

40047025 Pipeheat25,0mCableforinternalinstallationinpipes 275W

40047000 NippleforPipeheat1/2“-3/4”transition

Frost Guard with thermostat Plug-in self-regulating cable

Heatcom“Plug-in”self-regulatingheatingcableforfrostprotectionofinternalorexternalpipes.Approvedfordrinkingwaterpipes.

ThecoldendhasanintegralearthedSchukoplugadaptedforNorwegianconditions.Thisinstallationdoesnothavetobedonebyanauthorisedelectrician.

Toachievethebestpoweroutput.insulationmustbeplacedaroundthecompletedinstallation.

Page 9: Electric underfloor heating • Simple to install • Cheap to install • … · 2020-01-21 · Electric underfloor heating • Simple to install • Cheap to install • Simple

8

Heatcomcanofferacompleterangeofself-limitingheatingcables.Forfrostprotectionofpipes,ice-freeguttering,andcableswithtemperaturesupto240oC.

Heatcomself-limitingheatingcablescanbesuppliedincut-to-measurelengthsoronadrum.

Thecableshavethenecessarycertificatesandcomplywithallinternationalstandards.

Heatcom heating cable Industrial range

Heatcom self-regulating heating cable

Heatcom heating cables for laying in concrete. Inside or outside 25W/running metre

Heatcom heating cable for hardening concrete

Heatcom7mmheatingcableisanall-roundheatingcablethatisusedwhereyouneedahigherpoweroutputpersq.msuchasforsnowmeltingorasaheatingcableonpoorlyinsulatedsurfaces.

Thecableisnotintendedforlayinginwarmasphalt.

Heatcomoffersaspecialheatingcableforlayinginwarmasphaltthatcanbesuppliedonadrumorasacableonmat.Lengthsfrom9.5mto135mandpoweroutputfrom232Wto3410W.

HeatcomheatingcableforhardeningconcretewithattachedCEEplugfor16amp.

Thecableissuppliedasstandardinthreelengths.18m/730W.36m/1420W.86m/3515W

Heatcom has flexible production of products for underfloor heating. Only a small selection of the frost prevention range is presented in this catalogue.

Please ask for other dimensions and types that are not shown in the tables.

We supply most of your floor heating and frost prevention needs.

Page 10: Electric underfloor heating • Simple to install • Cheap to install • … · 2020-01-21 · Electric underfloor heating • Simple to install • Cheap to install • Simple

Some examples of how to build a heated floor:

Heating cables must always be placed on an even. clean and stable surface. Insulation under the heating cables considerably increases the effect. Heating cables can be placed directly on insulation and wood. but the cables must be covered with flexible primer so that the heat is conducted up to the floor. The material in which the cable is placed must be self-supporting. i.e. be at least 30 mm thick.

Lowprofileheatingcable3mminflexibleprimer.Flexibleprimermusthaveaminimumthicknessof5mm.

Flexibleprimerandadhesivemustbein-tendedforunderfloorheating

Lowprofileheatingcable3mmoninsulation.Requiresself-supportinglayeratleast30mmthick.

Thesurfacemustbestabletoavoidcracking.

Heatingcable5.5mminscreed.Maybeplacedonreinforcementor5mmreinforcednet.

Theremustbenoairpocketsinthescreedandtheheatingcablesmustbecompletelycoveredbyflexibleprimer/tileadhesive.

9

Heating cables must be connected by an authorised electrician.

Page 11: Electric underfloor heating • Simple to install • Cheap to install • … · 2020-01-21 · Electric underfloor heating • Simple to install • Cheap to install • Simple

Important instructions relating to your electric floor heating.HeatcomunderfloorheatingisapprovedinaccordancewiththecurrentEN60335-2-96standard.Thefollowingpointsmustbetakenintoconsiderationtogetherwiththeinformationonelectricunderfloorheating.

Read the following information carefully before installing the underfloor heatingUnderfloorheatingcanbelaidinsuitabletileadhesive(askthesupplierwhichtypeofadhesive)incement/concrete.orflexibleprimer(askthesupplierwhichtypeofflexibleprimer).Heatingcablescanalsobelaidonawoodensub-floor.qUnderfloorheatingmustnotbeinstalledinwallsorceilings.qUnderfloorheatingmustbepositionedatleast30mmfromelectricalinstallations.Anoverviewofelectricalandotherinstallationsmustbeavailablebeforeinstallingunderfloorheating.Thisrelatestocablesandwaterpipes.qUnderfloorheatingmustnotbepositionednexttoothersourcesofheatsuchaschimneys.lightsources.andhotwaterpipes.

qThetemperatureofthesurroundingsmustbeatleast5oCwhentheunderfloorheatingisinstalled.qWhereverpossible.theremustbegoodinsulationbelowtheunderfloorheating.Thissavesenergy.qUnderfloorheatingmustbeinstalledonanevensurface.qUnderfloorheatingmustbeconnectedbyanauthorisedinstaller.qUnderfloorheatingmustbeconnectedtoagroundfaultcircuitinterrupterofmax.30mA.qIfseveralheatingcablesaretobeconnectedtogethertothesamethermostat.theymustbeconnectedinparallel.Thelocationofunderfloorheatingmustbeindicatedinanappropriateplaceinthefusebox.qThermalresistance/blocking(floorcovering+carpetorsimilar)betweentheheatingcablesandtheroommustbemax.0.125m²K/W.

qTypicalinsulationvalues: Floorcoveringoftilesorvinyl: 0,035m²K/W Mediumthicknessfloorcoveringoflinoleum.vinylorsimilar: 0,040m²K/W Woodandparquetfloors: 0,125m²K/W Thickfloorsofwoodfibreandcarpets: 0,175m²K/W

qUnderfloorheatinglocatedunderwoodfloorsmusthaveafloorsensorinstalled.qUnderfloorheatingmustbeplacedinanapprovedscreed.Forexample.tileadhesive.cement/concrete.flexiblefillerorsimilar. wThescreedmusthaveadensityofatleast1500kg/m3 wThescreedmusthaveathermalconductivityofatleast1W/mK. wThescreedmusthaveauniformqualitythroughouttheentirearea. wThescreedmustbecastinalayeratleast5mmthick.Theheatingcablesmustbefullyenclosedbythescreed. wAirpocketsmustnotoccurandarenotpermittedaroundtheheatingcablesandinthescreed.

w Thescreedmustnotinsulateorcontainairpocketsorotherinsulatingmaterials.

wIfheatingcablesarelaidonwoodconstructions.thesemustbeonastablesub-floorandthecablesmustbelaid insuchawaythatanymovementintheconstructioncannotdamagetheheatingcables. wCaremustbetakenwhenlayingheatingcables.Avoidwalkingonthecablesordamagingthecablesbydroppingsharpobjectsonthefloor.Cablelaidonreinforcedironmustbeintendedforthatpurpose.andcare mustbetakenwhenpouringconcrete. wAvoidfoldsintheheatingcables. wThecablesmustnotcrosseachother. wMakesurethatallcablesandconnectionsareplacedwelldowninthescreed. P HeatingcablesmustbeinstalledinaccordancewithNEK400. Otherrelevantregulationsrelatingtoelectricunderfloorheatingmustalsobecompliedwith PThermostats: MustbeCE-markedandapprovedfortheintendeduse. Electricunderfloorheatingsystemsmustbeconnectedtoadoublepoleswitch.Ifthethermostatissingle pole.adouble-poleswitchmustbepositionedbeforethecircuit.

w Maximumpowerunderwoodenfloorsis80-100W/m2-230VAC(160W/m2-240VAC) wMaximumpermittedpowerpersquaremeteris200W

INFORMATION – PRIMARILY FOR YOUR INSTALLER…….!

10

Page 12: Electric underfloor heating • Simple to install • Cheap to install • … · 2020-01-21 · Electric underfloor heating • Simple to install • Cheap to install • Simple