Upload
others
View
7
Download
0
Embed Size (px)
Citation preview
HEATING TECHNIQUE
CENTROMETAL Oil and Gas boilers EKO-CUP S3 (125-600kW)
EKO-CUP S3 steel hot water boilers (heat output range 125 – 600 kW) are engineered to meet heating requirements in the middle to large premises, as well as to be the heat source for manufacturing and processing. The boiler can be configured as a stand alone unit or as a series of modular units.This product is a synthesis of modern technologies and is presented in high quality materials ready for simple and easy assembly and operation. The fully developed and tested technical solutions applied assure these boilers are safe and reliable. The triple-pass flue gas flow system is a key element of their low energy consumption. The wide range of available control devices, as additional equipment, enables the customer to benefit from a fully automatic direct or remote controlled heating center.
PRODUCT CHARACTERISTICS
EFFECTIVEBuilt-in turbulators allow better heat transfer from flue gas to boiler water.
REGULATIONThe basic boiler control operates by the operation of a two-burner burner according to the boiler’s default boiler temperature.
ISOLATION
A special feature is the exceptional thermal insulation of the boiler.
INSTALLATIONDelivered in parts that allows easy transportation and installation of the boiler.
• Hot water boilers for central heating systems a with triple-pass flue gas flow
system (heat output range 125-600 kW).
• It is economical and ecologically acceptable, with high efficiency and low NOx
levels.
• Max. operating boiler pressure is 3 bar (standard) or 6 bar (custom made) and
max. operating temperature is 90°C (standard), 100°C or 105°C (custom
made)..
• Built in turbulators enable better heat flow from flue gas to water, better
regulation of gas flow in the combustion chamber, better regulation of the
output temperature of flue gas, i.e. high quality balancing of the functions of
the boiler, burner and chimney.
• A large volume of water in the boiler reduces the number of start ups,
prolongs the life of the burner and saves energy.
• Design and construction provide extremely low start-up condensation.
• All connections are mounted on the upper side of the unit enabling simple
assembly.
• The boiler is delivered with plugged in thermic regulation together with
connecting points for an outdoor temperature controller, which enabling fully
automatic operation of the heating system.
Contact phone: +371 28818088, +371 29149923 E-mail: [email protected]: www.centrometal.lv
• Basic boiler controller controls the operation of a two-stage burner according to set values for boiler temperature.
• A special feature is the high performance thermal insulation.
• Boiler door with blind panel is adequate for installation of all fan burners available on the market and can be opened both
to the left and right for 90° which enables simple and fast boiler cleaning.
• The body of the boiler is delivered separately from the casing and thermal insulation which enables transportation and
assembly.
EKO-CUP S3
HEATING TECHNIQUE
CENTROMETAL Oil and Gas boilers EKO-CUP S3 (125-600kW)
Contact phone: +371 28818088, +371 29149923 E-mail: [email protected]: www.centrometal.lv
Boiler EKO-CUP S3Blind panel for installation of fan burnerBoiler water inlet
Boiler water outletSafety lineBoiler flue gas exhaust
Opening for cleaningFilling / DrainingBoiler regulation9
I
K
C
F
H
G
B=E A
D
9
EKO-CUP S3 125 160 240 320 400
Heat output range
Boiler water content
Boiler mass
Max.operat. temperature
Max. operat. pressure
Flue gas exhaust diameter / height (I)
Burner opening
Boiler chamber resistance
Boiler water inlet/outlet connection (NP6)Filling / Draining
Safety line
Flue gas temperature
Length of the body A
Width of the body B
Height of the body C
Total length D
Total width E
Total height F
Height G
Heights (H / K)
kW
l
kg
°C
bar
mm
Ø mm
mbar
R
R
°C
mm
mm
mm
mm
mm
mm
mm
mm
37,5-125
225
445
90/100/105
3-6
180/700
130
1,7
R2”
3/4”
1”
140
1630
780
970
1660
780
1080
910
360/175
48-460
290
563
90/100/105
3-6
200/790
130
2,5
DN 50
3/4”
1”
140
1475
945
1110
1510
945
1195
1040
440/175
72-240
390
673
90/100/105
3-6
200/790
170
2,6
DN 65
3/4”
5,4”
140
1890
945
1110
1930
945
1210
1040
440/175
96-320
465
867
90/100/105
3-6
250/890
170
2,8”
DN 80
3/4”
6,4”
140
1890
1050
1225
1930
1050
1320
1150
440/175
120-400
615
1066
90/100/105
3-6
250/970
170
3,5
DN 80
1”
6,4”
140
1945
1150
1355
1985
1150
1420
1250
450/185
460 530 600
138-460
735
1184
90/100/105
3-6
250/970
220
4,0
DN 80
1”
6,4”
140
2245
1150
1355
2285
1150
1420
1250
450/185
168-530
865
1418
90/100/105
3-6
300/1062
220
4,3
DN 80
1”
6,4”
140
2245
1250
1460
2285
1250
1520
1350
475/185
180-600
970
1515
90/100/105
3-6
300/1062
220
4,9
DN 100
1”
6,4”
140
2495
1250
1455
2530
1250
1520
1350
480/185
Delivery of EKO-CUP M3Body of the with casing and basic
boiler controller, cleaning set.
Basically diagram of connection
to hydeaulic separator with
basic boiler control:
1. Boiler EKO-CUP S3
2. Hydraulic separator
3. Motor operated 3-way mixing valve with
SBE CRA controller (60°C)
4. Tested safety valve
5. Heat pump thermostat
6. Expansion vessel
7. Oil/gas burner
8. Thermal pipe insulation
M
1
2
3
5
4
6
7
8