Upload
sasastole
View
94
Download
3
Embed Size (px)
Citation preview
E-InstallationElectr ica l Inst a l lat ion f rom A to Z 6th edition 4-2005
s
Content
Market & Industry
Great deal of interest from consumers shows the need forconsultation 2
Building System Engineering
Pushing the right buttons, even in the dark 3Life-saving radio communication 3High-grade electrical engineering in the Colosseo 4Sports, Games and Fun 6Berufsluft schnuppern 9From the same mold 10Easy dimming of large loads 10
Installation Equippement
User-friendliness and precision 11Live and error-free 12Tailor-made, combined protection 13Steckdosen 5TE6 8 14Remote-controlled mechanism for RCCBs 14
Power Supply & Distribution
Regional wandlungsfähig 15Kurzschluss-Schutz mit Zollsicherung 15Einfach einschieben 16Gut aufgehoben 16Messwerte übersichtlich dargestellt 17
Service & Dialogue
KNX/EIB all packed up 18Beratung tut Not 19Building on a solid basis 19
Siemens ArenaVilniusBuilding Systems Engineering for Perfect Event
Ed
ito
ria
l
Liebe Leserinnen und Leser,
Kleine Dinge entfalten oft großeWirkung. Manchmal entsteht dieseWirkung aber auch, wenn kleineDinge fehlen: Rauchmelder bei-spielsweise. Dies zeigen jüngsteFälle, bei denen zum Teil hoheSachschäden entstanden, leideraber auch wieder Menschen zu
Schaden oder gar umsLeben kamen. Derfinanzielle Aufwand für die elektronischenWächter erscheint imNachhinein dagegenmeist gering. Unsereneuen Rauchmelder mitFunkmodul machen es
dabei noch einfacher, vor Ort zuwarnen und den Alarm an einezentrale Stelle weiterzuleiten (S.3).Besser als jede Alarmvorrichtung istes sicher, wenn erst gar nichts an-brennt. Hier kommt der modernenInstallationstechnik eine außeror-dentlich wichtige Rolle zu. Denn zu den häufigsten Brandursachenzählen immer noch fehlerhafteelektrische Geräte und Fehler inelektrischen Anlagen. Leitungs- undFI-Schutzschalter, die im Fehlerfallblitzschnell abschalten, können hierdas Risiko begrenzen. Die Kombi-nation von FI/LS-Schaltern in einemGerät eröffnet darüber hinaus neueMöglichkeiten da, wo umfassenderSchutz bei gleichzeitig hoher Ver-fügbarkeit der elektrischen Anlagegefordert ist (S.14). Außerdemblicken wir in diesem Heft zurückauf zwei Projekte, an derenGelingen vor allem auch unserePartner im Handwerk maßgeblichbeteiligt waren.
Viel Spaß beim Lesen wünschtIhnen
Godehardt Schneider, Leiter des Siemens-GeschäftsgebietesInstallationstechnik
2 E-Installation 4-2005
Ma
rke
t&
Ind
utr
y
Siemens A&D has formed a strategic part-nership with Phoenix Contact GmbH & Co.KG, thus strengthening its position in termi-nal block and overvoltage protection prod-ucts in electrical installation technology. Un-der the terms of the partnership, from nowon Phoenix Contact will take over the pro-duction and further development ofSiemens’ range of terminal blocks, whileSiemens will continue to provide existing
Working in partnership with Phoenix Contact on terminal blocks and overvoltage protection
Mutual Protection
terminal block screw-type connection sys-tems. In future, Siemens will purchasescrewless connection systems for terminalblocks and overvoltage protection productsexclusively from Phoenix Contact and sellthem under the Siemens name. This putsSiemens in a position where it can offerthese sectors a full range of products andserve the market better with tailored solu-tions. n
Siemens Automation and Drives (A&D) pre-sented its range of electrical installation sys-tems at the Consumenta show in Nuremberg,Germany, for the first time from October 29 toNovember 6.
On show were the possibilities offered bycentralized switching of lights and blinds bothinside and outside, as well as solutions for sav-ing energy and protecting house and home, aswell as expensive electrical equipment, fromdamage caused by lightning and overvoltages.
Together with the Electrical Trade Guild(Elektroinnung) of the German region of Fran-conia, Siemens informed visitors to the con-sumer show about issues such as E-Check andthe cross-vendor HEA “Convenient installation”
Electrical Installation from A to Z appears together with the Electrical Trade Guild at the Consumenta show in Nuremberg, Germany
Great deal of interest from consumersshows the need for consultation
campaign (HEA is the German Trade Associa-tion for Energy Marketing and Applications).Visitors with an interest in building and reno-vation were provided with information aboutthe wide variety of possibilities opened up bymodern electrical installation systems. “Nowa-days, builders and renovators often do not payenough attention to the scope of their electri-cal installation equipment. On the one hand,this brings with it the risk that the number ofsockets, communication terminals, aerial sock-ets, or light outlets will have to be changed ata later date, which can be expensive in termsof both time and money; on the other hand, itcould even constitute a safety hazard, if insuf-ficient sockets are provided for the number of
devices. In any case, thosewishing to construct build-ings should plan the scopeof their electrical installationequipment early on in theprocess, together with archi-tects or electrical experts,”says Godehardt Schneider,Head of the Electrical Instal-lation Technology Division atSiemens A&D. We can put in-terested parties in touchwith a local consultant elec-trician on request. nSi
emen
sA
G
E-Installation 4-2005 3
The new UP 221 (single) and UP222 (double) pushbuttons featur-ing LEDs can be combined withall components from the univer-sal Delta i-system pool. Theymatch the frames found in theDelta line, Delta vita and Deltamiro switch ranges (not includedin the scope of delivery). Bothpushbutton versions are availablein four colors: electrical white, ti-tanium white, carbon metallic,and aluminum metallic. The LEDbuilt in next to the right-handrocker's (or rockers') tactile touchcan be used as a status indicatorfor the connected object or as a
light to aid orientation. The push-buttons can only function if usedin conjunction with the UP buscoupling unit (not included in thescope of delivery) and an appli-cation program suitable for theapplication in question. Applica-tion programs are provided forswitching, dimming with a STOPmessage or cyclic sending, shut-ter/blind operations, and slat ad-justments. The opposite pushbut-tons always form a pair that be-longs together, for example, theleft pushbutton is used for switch-ing on and the right pushbuttonfor switching off. Associated ad-
DELTA reflex battery smoke detector
Life-saving radiocommunication
UP 22* pushbutton with LED for GAMMA instabus
Pushing the rightbuttons, even in the dark
The wave uni M 252smoke-detector modulemakes the Delta reflexbattery smoke detectorsuitable for radiotransmission
GAMMA instabus via the wave/in-stabus coupling unit, where theycan be displayed and furtherprocessed on any display/alarmunits you wish. The radio moduleis inserted in the available slot onthe Delta reflex smoke detectorand supplied with current by thesmoke detector’s batteries. Evenwith the radio module connected,the battery service life remains atfive years. n
The wave uni M 255 smoke-de-tector module extends the func-tionality of the Delta reflex bat-tery smoke detector by addingthe option of radio communica-tion. When smoke is detected,this means that, in addition to alocal alarm sounding on thesmoke detector, an alarm is alsooutput via radio. As well as thesmoke alarm, which the moduleoutputs via radio, a switchingcommand is also sent to the ra-dio-linked switch actuators,which then activate the con-nected alarm sensors, such ashorns, sirens, warning lights, etc.If the battery needs to be re-placed, the detector indicatesthis both visually and acousti-cally. This alarm message isalso output via radio.Touch-Manager wavecan then display thealarm message andswitching commandwhen smoke is de-tected, as well as infor-mation about the de-tector’s battery status,or this data can betransferred to the
UP 222 pushbutton, Delta linedesign, aluminum metallic
UP 222 pushbutton with LED,Delta miro design, carbonmetallic
jacent pushbuttons are inter-locked in the software, so that amalfunction will not occur if bothare pushed simultaneously. The“EIB Tool Software” (ETS) can beused to select the application pro-grams, which assign specific pa-rameters and addresses and aretransferred to the UP bus couplingunit. n
Bu
ild
ing
Sys
tem
sE
ng
ine
eri
ng
iLinks to the topic:www.siemens.de/gamma
Contact: [email protected]
Delta reflex battery smokedetector
Siem
ens
AGFo
tos:
Sie
men
s A
G
Siem
ens
AG
UP 221 pushbutton with LED,Delta vita design, carbonmetallic
4 E-Installation 4-2005
High-grade electrical engineering in the ColosseoElectrical installations for hotel complex require the cooperation of specialized enterprises
The newly built Hotel Colosseo in the
Europa Park in Rust has been creating
holiday mood mixed with southern
flair, even though it is to the north of
the Alps, for more than a year now.
The luxury hotel with around 1450
beds near Freiburg in Breisgau, Ger-
many, is based on a typical Italian city
silhouette. The most modern electri-
cal engineering technology from
Siemens is hidden behind the renais-
sance facades and the colosseum
arches. Four partner companies have
contributed with their special expert-
ise in building technology, lighting
and safety devices to ensure unre-
stricted comfort for the guests.
The fact that the contract for the electrical in-
stallation was awarded to companies in the
region was exactly what the engineering de-
partment of the Europa Park wanted. They at-
tach great importance to direct contact with
the specialized trades and to quick service. As
a contract supplier, Siemens fulfils the high
demands on technology with its product plat-
forms “Totally Integrated Power” and “Total
Building Solutions”, with integrated quality
from a single source.
Up to 100 installation technicians at theconstruction site
The complete installation contract, i.e. the
power supply from the substation all the way
to the circuits, internal and external lighting,
safety equipment, building automation with
KNX/EIB, was awarded to EGT Gebäudetechnik
GmbH in Triberg. This was no small challenge
even for the electrical engineering specialist
and despite their experience in large projects:
“After all, the order was worth 3 million
euros and had to be carried out within a pe-
riod of only eleven months”, emphasizes
manager Leonhard Häringer. According to the
specifications of the planning department, ex-
tensive implementation plans were to be pre-
pared based on the installation processes.
Technical personnel, e.g. engineers, foremen
and technicians of EGT, together with the pur-
chasing department and construction man-
agers, made sure that the materials were
available in time and sufficient technicians
were always present on site at the right time
Project management by EGT: Behind the historic facade of the Colosseo in the Europa Park in Rust, state-of-the-art electricaltechnology ensures cost-effectiveness, comfort and safety
Bu
ild
ing
Sys
tem
sE
ng
ine
eri
ng
Euro
pa-P
ark
Euro
pa-P
ark
Häg
ele
Ideas for the optimization of the EIB installation:Electrical specialist Paul Joseph (right) and“chief technician” Viktor Weber (left)
for processing the material. “Naturally, in de-
tailed coordination with the building progress
and the other services; even if we just consid-
ered routing and short-term changes; some-
times we had up to 100 technicians at the con-
struction site”, says Häringer as he describes
the complexity of project management. Fi-
nally the electrical system could be delivered
in time: according to Häringer, everyone – the
employees and the subcontractors - acted in
concert. EGT assigned parts of the order to
other specialists.
Power distribution as a daily challenge
One such special field is the installation of
low-voltage distribution systems. Due to the
TV productions taking place in the hotel area,
a high connected electrical load of 2,000 kVA
via two transformers as well as an emergency
power supply of up to 630 A was required.
Correspondingly two low-voltage distribution
systems with 20 outgoing feeders from 250 A
to 630 A were required.
SP Elektrotechnik GmbH in Freiburg ob-
tained the order, an almost every-day chal-
lenge for the switchgear manufacturer. The
licensed Sivacon partner uses the tool Simaris
design: “Thus the number of components is
quickly calculated and the field services plan
displayed, taking the dimensioning into ac-
count”, explains the head of sales, Hans Maier.
E-Installation 4-2005 5
Bu
ild
ing
Sys
tem
sE
ng
ine
eri
ng
iLinks to the topic:www.siemens.de/gammawww.siemens.de/europapark
Contact: [email protected]
The type-tested Sivacon busways were equipped
with circuit-breakers and in-line fuse switch
disconnectors, wired, and punctually deliv-
ered to the construction site.
Building management systems with over1700 data points
ssg starkstrom systeme GmbH, Freiberg, has
been responsible for the control of the fun
rides at the Europa Park for many years. But
this order included the challenge to integrate
all the technical units of the hotel complex in
a central building management system, i.e.
heating, ventilation and air conditioning
(HVAC), cryogenics, swimming pool technol-
ogy, electrical installation and lighting as well
as the security systems. The system integrator
integrated over 1700 data points via Ethernet,
LON and KNX/EIB. ”This means efficient en-
ergy management and cost-effective building
management” explains the Head of Sales,
Gerd Glückler, referring to the purpose of
building management. To ensure that no en-
ergy is wasted and the guests feel comfort-
able all the time, the temperature and air
quality in the restaurant, in the conference
area and in the swimming pool is checked and
evaluated for further optimization at a central
location. Error signals from technical systems
can be quickly forwarded to the responsible
maintenance personnel.
Ideas with KNX/EIB
When in the Colosseo the facade lighting of the
Piazza is required to create a special mood, this
is no wizardry for the electrician, Paul Joseph.
The “in-house electrician” of the Europa Park,
has implemented the complete installations in
the technology-intensive areas, such as restau-
rant, hotel bar and the kitchen as well as the EIB
control for internal and external lighting and
helped parameterize many other functions.
”Our part doesn’t end there, though. In the fu-
ture, too, we will be looking after the entire
KNX/EIB system with approx. 1200 stations”, ex-
plains the electrical specialist, Paul Joseph.
Since completion, there has been no lack of
ideas regarding the optimization of functions.
The flags are fully automatically secured, the
frost protection device for palm trees is con-
trolled or, if it is windy at the Piazza, the water
pressure of the fountain is automatically throt-
tled so that the guests can walk around without
getting wet. At present they are searching for a
visualization solution for manually creating
lighting scenarios. Almost daily an EIB spe-
cialist is on site. Joseph enjoys the fact that his
range of services offered has been expanded.
”In the future they will retrofit this impressive
technology even in the older hotels of the Eu-
ropa Park, to save energy and increase com-
fort", he predicts. n
Euro
pa-P
ark
EGT
Häg
ele
EGT
Local workshop: Switchgear manufacturedby SP Elektrotechnik
Flexible light scenes in the bar made possibleby KNX/EIB
Thanks to perfect project management byEGT, the Colosseo lights up in the right light
Vilnius, the capital of Lithuania, is
home to the Siemens Arena, the
largest and most modern multi-
purpose arena in the Baltic region.
Like its Hanseatic counterpart, the
Color Line Arena in Hamburg, the
Siemens Arena not only stages
sporting events, but also music,
entertainment, and business events.
6 E-Installation 4-2005
Sports, Games and FunModern technology enables perfectly staged events in the Siemens Arena
Bu
ild
ing
Sys
tem
sE
ng
ine
eri
ng
Sch
alt
er
&St
eck
do
sen
E-Installation 4-2005 7
Bu
ild
ing
Sys
tem
sE
ng
ine
eri
ng
Whether a basketball game or aconcert, the lighting control systemalways provides the right lighting
8 E-Installation 4-2005
More than 500,000 visitors annually from all
over the Baltics are expected to fill the five
floors of the 20,000-square-meter venue. The
Rubicon Group, the arena owner and opera-
tor, managed to find a partner in Siemens
who could supply the entire building tech-
nology from a single source, complete with
products, systems, and solutions meeting
highest quality and safety standards. Client
specifications included the central building
control system, ventilation and heating con-
trol, the lighting system, a video surveillance
system, access control and a fire alarm sys-
tem, further complemented by communica-
tions as well as low-voltage equipment.
Playing to the right light
Siemens installed the entire building tech-
nology within a very short construction time
frame of only eight months, which is con-
trolled and monitored by a building man-
agement system (Desigo Insight). A single
computer is all that is needed to ensure that
players and performers are effectively and
reliably cast in the right light. The climatic
conditions inside the arena are controlled
automatically, even at high temperatures.
And should the public power supply fail, the
system automatically switches to the arena’s
independent power supply.
Another feature integrated into the build-
ing management system is the Gamma in-
stabus EIB lighting control system, which en-
sures optimal, glare-free visibility. With
Gamma instabus, various scenarios, individ-
ually adapted to the respective event, can be
called up at the push of a button. Lighting re-
quirements for training sessions, for exam-
ple, differ from those for internationally
broadcast television events – also in terms of
power consumption. Thanks to sophisticated
systems, the arena’s entire lighting can be
switched on and off at a central location, and
individual lamps or the lighting of specific
areas controlled from a PC.
For the power supply – which is also sup-
plied from a single source – huge batteries
and diesel generators ensure that power is
available even if the arena’s power supply
should unexpectedly fail. Here, Sikus uni-
versal HC low-voltage control and distribu-
tion systems, Alpha installation and floor-
mounted distributors, and Beta circuit break-
ers were installed.
An addressable fire detection system
along with 900 smoke detectors handle fire
protection duties. In the event of a fire, one of
nine specially developed programs such as
“activate fire-extinguishing equipment” or
“close fire protection flaps” is set into mo-
tion, all depending on where the fire is lo-
cated. A video surveillance system (CCTV),
which reports events to the control center 24
hours a day via 27 fixed and five rotatable
cameras as well as two digital recording de-
vices, was also installed for safety and secu-
rity reasons. The safety and security solution
is supported by the CerPass integrated ac-
cess control system. 45 non-contact card
readers and seven controllers grant only au-
thorized persons with VIP cards access to the
VIP areas, the elevators as well as to the em-
ployee areas.
The Siemens Arena is the first project of
this size in Lithuania in which telecommuni-
cations and building management technolo-
gies for heating, ventilation, air conditioning,
and lighting were combined for all areas. n
iLinks to the topic:www.siemens.de/gamma
Contact: [email protected]
Card reader in front of the VIP lounge: mod-ern reader design of the Delta miro serieswith real glass frame. The VIP lounges offerthe best views in the arena.
Bu
ild
ing
Sys
tem
s E
ng
ine
eri
ng
E-Installation 4-2005 9
Berufsluft schnuppernKreishandwerkerschaft Essen bildet an Siemens-Gebäudesystemtechnik aus
Das Handwerk stellt in der Ruhrge-
bietsmetropole Essen, der sechst-
größten Stadt Deutschlands, einen
bedeutenden Faktor im Wirtschafts-
leben dar. In rund 4600 Handwerks-
und handwerksähnlichen Betrieben
mit mehr als 48.000 Mitarbeiterinnen
und Mitarbeitern werden 3200 Lehr-
linge ausgebildet. Das Spektrum ist
breit gefächert und reicht von der
unmittelbaren Versorgung der Essener
Bevölkerung mit Gütern und Dienst-
leistungen des täglichen Bedarfs, über
die Deckung gehobener Ansprüche bis
zur Zulieferung für die Industrie sowie
zu Instandhaltungs- und Instandset-
zungsarbeiten.
Im Haus des Handwerks in Essen werden im
Auftrag der Handwerkskammer Auszubil-
dende des Elektrohandwerks in überbetrieb-
lichen Lehrgängen (ÜBL) und in einer über-
betrieblichen Ausbildung (ÜBA) auf ihr Ar-
beitsleben vorbereitet. Elektronikerinnen und
Elektroniker der Fachrichtungen Automati-
sierungstechnik sowie Energie- und Gebäude-
technik erhalten hier während ihrer Aus-
bildung insgesamt zehn einwöchige Unter-
weisungen. Sie bereiten sich so auf ihre
Prüfungen vor und legen diese auch im Haus
des Handwerks ab.
Die Auszubildenden montieren mechani-
sche Teile, elektrische Geräte und Komponenten
und nehmen diese in Betrieb. In der Fachrich-
tung Energie- und Gebäudetechnik setzen Sie
sich mit der elektrischen Energieversorgung
und anderen elektrotechnischen Anlagen in Ge-
bäuden auseinander. Sie planen und installie-
ren Sicherungen und Anschlüsse für Hausge-
räte, Beleuchtungsanlagen, Torantriebe, Ge-
bäudeleiteinrichtungen, Datennetze sowie die
Steuerungs- und Regelungseinrichtungen von
Heizungs-, Lüftungs- und Klimaanlagen. Sie er-
stellen Steuerungsprogramme, messen elektri-
sche Größen und führen Systemtests durch.
Außerdem prüfen sie elektrische Schutzmaß-
nahmen und Sicherheitseinrichtungen. Sie er-
mitteln Störungsursachen und beheben diese.
Die Lösung
Um sich optimal auf das Berufsleben vorzube-
reiten, werden die Lehrpläne immer wieder den
neuen Anforderungen angepasst. Auch Ver-
kaufsförderung und Marketing stehen auf dem
Lehrplan. Die Ausbildungsleiter treten hierbei
als Partner, Berater und Motivator auf. Wichtig
ist, immer wieder auf die aktuellen Anliegen
innerhalb der Gebäudetechnik hinzuweisen:
energiesparende Elektroinstallation und quali-
tativ hochwertige Produkte. Die Ausbildung am
EIB (Europäischer Installationsbus) und in der
Funktechnologie sind wichtige Schwerpunkte
im neuen Berufsbild des Elektroinstallateurs.
Auf Anfrage stattete Siemens das Haus des
Handwerks in Essen mit EIB-Komponenten und
Gamma wave-Funktechnik aus. Hierbei steht
nicht das Verdrahten im Vordergrund, sondern
das Programmieren. Eine Aufgabe für die Lehr-
linge ist beispielsweise das Umrüsten von kon-
ventioneller Technik auf EIB. Dazu gehört die
Wechselschaltung in EIB-Technik wie auch die
Temperaturregelung und Jalousiensteuerung
mit der Funktechnik Gamma wave. Auch Prüf-
und Testgeräte werden von den angehenden
Elektronikern selbst gebaut. Der Ausbildungs-
leiter kann die Arbeiten jederzeit von einer zen-
tralen Stelle aus überprüfen und Tipps geben
für die Fertigstellung der Projekte.
Vorteile für die Kreishandwerkerschaft Essen
„Gerade für Elektroniker im Bereich Haus- und
Gebäudetechnik ist es wichtig, auf dem mo-
dernsten Stand der Technik zu sein. Deshalb
bilden wir die jungen Leute an Produkten aus,
mit denen sie für die Zukunft gewappnet sind.
Was nützt es, wenn Sie zwar die Standardar-
beiten wie das Verdrahten beherrschen, jedoch
mit EIB und moderner Funk-Technik nichts an-
fangen können. Die jungen Leute, die zu uns
kommen, erwarten im Übrigen auch von uns,
dass wir sie zu hoch qualifizierten Handwer-
kern ausbilden, die am Ende ihrer Ausbildung
mit der modernen Welt der Gebäudetechnik
locker umgehen können. Siemens hat uns bei
der Ausstattung unserer Schulungsräume un-
terstützt und uns die Produkte zur Verfügung
gestellt, um diesem hohen Anspruch gerecht
zu werden“, Herr Schuster, Ausbildungsleiter
Elektriker- und Installateur-Meister, Kreis-
handwerkerschaft Essen. n
Kreishandwerkerschaft Essen
Die Kreishandwerkerschaft Essen ist eineKörperschaft des öffentlichen Rechts undein Zusammenschluss von 32 Innungendes Essener Handwerks. Ihre Aufgabe istes, in erster Linie die Interessen desörtlichen selbstständigen Handwerks zuvertreten. Neben der Mitwirkung imBereich von Gemeinschaftseinrichtungendes Handwerks und der Gestaltung desInnungslebens liegt der Schwerpunkt derArbeit bei der Beratung der Mitglieder inFragen, die mit der Ausübung einesselbstständigen Handwerksbetriebs inZusammenhang stehen, wie beispiels-weise arbeitsrechtliche Angelegenheiten.
Kreishandwerkerschaft Essen bildet mit Gammawave-Koffern junge Elektroinstallateure aus
Übung macht den Meister
Auszubildende testen die Funktionsweisenvon Gamma wave
Bu
ild
ing
Sys
tem
sE
ng
ine
eri
ng
iLinks to the topic:www.siemens.de/gamma
Contact: [email protected]
Alle
Fot
os: S
iem
ens
AG
It is now even easier and faster toconfigure and commission thenew digital inputs, switch actua-tors and blind actuators, and itcan also be done in a more con-sistent manner. This is because,in the new delivery condition,only the communication objectsthat are essential for minimumfunctionality are visible. Thismakes standard commissioningvery simple. If required, otherfunctions and objects can alwaysbe switched on using the ETS. Toensure problem-free parameteri-zation, the system startup engi-neer has the choice to either pa-rameterize all channels identi-cally or to parameterize themindividually. The new housing de-sign supports this simplicity.Some new features have thusbeen implemented in the newdevices, irrespective of the hous-
ing width. For devices with a linesupply, an LED indicates whethera line voltage is present (230 V).The user has the option to togglebetween the “direct operation”
and “bus operation” modes usinga standard pushbutton with inte-grated LED. The LED indicates thecurrent operating status. On theactuators, the outputs can eachbe controlled in direct operationvia an integrated pushbutton(there is a separate button foreach output). LEDs indicate theswitching state here, too.
Expanded bus interface
The bus interface to the deviceshas been standardized furtherand is now possible via bus ter-minals as well as via a contactsystem and data bus. This elimi-nates the need for a connectorbetween the data bus and theconnecting cable or a data buswith connector. If the data-buscontact system is not in use, thesystem can be covered using aplastic cover, which is supplied
10 E-Installation 4-2005
Bu
ild
ing
Sys
tem
sE
ng
ine
eri
ng
Sw
itch
es
&S
ock
ets
5TC8 258 low-voltage rotary-dimmer insert8
Easy dimming of large loads
The 60 - 800 W/60 - 800 VA flush-mounting
low-voltage rotary-dimmer insert is suitable
for use as an off/gang switch for switching
and dimming incandescent lamps, high-volt-
age halogen lamps and low-voltage halogen
lamps with electronic transformers. The per-
missible load type is provided on the support
plate (new load marking), where it can always
be identified quickly. The device features an
electronic, short-circuit-proof fuse as well as
a self-resetting temperature fuse. The volt-
age at the connecting terminals can be tested
once the cover plate has been removed, with-
out having to remove the device insert. Screw
terminals with anti-slip clamping parts hold
both solid and flexible conductors in place
reliably. The +/- claw screws for fixing the dim-
mer in the flush-mounting socket can be
tightened using a flat-bladed or cross-tip
screwdriver. A trimpot enables the insert to
be optimally adapted to the loads. Cover
plates with a 5TC8... rotary button are re-
quired to operate the insert. The rotary po-
tentiometer’s high-quality soft latching dur-
ing dimming makes using it a pleasure. n
www.siemens.de/delta
Siem
ens
AG
5TC8 258 rotary dimmer for switching and dimming60–800 W incandescent lamps and high-voltagehalogen lamps and low-voltage halogen lampswith 60–800 VA electronic transformers
New housing design for switches and actuators
From the same mold
Uniform housing design makesparameterization simpler
Switch actuator with digitaloutput: Toggle between “directoperation” and “bus operation”
iLinks to thr topic:www.siemens.de/gamma
Contact: [email protected]
Siem
ens
AG
Siem
ens
AG
with the device. Overall, the newfeatures mean that configuringand commissioning all devices ismade easier, faster and moreconsistent. n
Siemens is now offering two new
ranges of mechanical and digital time
switches for the accurate switching
of electrical devices and systems.
All devices are characterized by very
simple operation and excellent
functionality and accuracy. The
digital time switches feature
integrated menu-assisted 4-key
plain-text operation.
The new mechanical time switches are avail-
able in “synchronous” and “quartz” versions.
With the synchronous time switches, the
switch-actuating wheel is driven by a syn-
chronous motor and is thus frequency-de-
pendent. However, with quartz time switches,
a quartz electronic circuit supplies the drive
with a stabilized frequency so that the clock is
not dependent on the line frequency. The de-
vice continues to run in the event of a power
failure. The 7LF5 3014 and 7LF5 3015 me-
chanical time switches are easy to install using
“plug & play technology.” The correct time
(CET) and day are set automatically during
commissioning using the fast mode. These
models also feature an automatic daylight-
saving adjustment, which means that the
clock is always set to the correct season auto-
matically (manual setting/resetting is no
longer necessary).
Simple digital
Mini, Top, Professional and Astro: These are
the four new time switching device ranges.
The clocks are as easy to program as those
found in cell phones. The time switch (Top,
Professional and Astro) guides the user
through the text menu in five languages, us-
ing four programming keys. Each required
entry is displayed clearly. The Professional
and Astro models can also be programmed
via a data key on the PC. To achieve this, the
data key is connected to the computer via a
USB adapter and programmed using dedi-
cated software. Once programs have been cre-
ated, they can be saved, edited, managed, and
reused time and again. Even complex control
programs can be created quickly and easily.
Programs on the data key can be transferred
by reconnecting it to another clock. The de-
vices are available in voltage variants of 24
volts, 120 volts or 230 volts, depending on the
model.
User-friendly switching
As well as daily and weekly programs, the dig-
ital time switches also feature many other
user-friendly functions. The Professional
model has what is known as a holiday pro-
E-Installation 4-2005 11
Inst
all
ati
on
Eq
uip
me
nt
iLinks to the topic:www.siemens.de/betawww.siemens.de/beta-news
Contact: [email protected]
User-friendliness and precisionTwo new ranges of mechanical and digital time switches
gram, which allows you to deactivate the
clock for a specific period. The random pro-
gram allows the switching times to be
changed randomly on a daily basis, which
simulates the presence of personnel within a
building. The devices are offered with either
one or two channels. The one-channel time
switch can be used as a pulse clock with up to
84 start times and an optional pulse duration
of between one and 59 seconds. It can be
used to control the recess bell in a school, for
example. A maximum of 56 control pro-
grams can be entered in the one-channel
time switch, while a maximum of 28 pro-
grams can be entered per channel in the two-
channel switch.
Astronomically good
Once the appropriate degrees of longitude
and latitude have been entered, the Astro
time switch calculates the sunrise and sunset
times for every day of the year. You can also
specify how long before or after sunrise/sun-
set the switching operation should take
place. The switching operation is thus
adapted to the building location automati-
cally. In this way, lights can be switched on in
the evening and off in the morning with in-
credible accuracy (i.e., to the very minute).
Blinds can also be closed in the evening and
opened again in the morning. n
Siem
ens
AG
7LF5 3014 quartz mechanical timeswitch with plug & play and automaticdaylight-saving adjustment
The 7LF4 4310 Astro digital timeswitch always knows when the sunwill rise and set
Easy to program: Create the controlprogram on the PC and save to the datakey via the adapter.
Live and error-freeOptimum plant availability thanks to all-in protection
The 5SU1 RCBO, part of the range of
Beta built-in installation devices,
provides combined personal, fire and
line protection in a single device. In
the event of an error, only the
affected electric circuit is disabled by
means of a switch, one of which is
available separately for each electric
circuit. The user benefits from
increased operational reliability and
plant availability.
Circuit-protection devices ensure that elec-
trical energy can be dealt with safely. The in-
creased use of residual-current-operated cir-
cuit-breakers (RCCBs) and miniature circuit-
breakers has made a particularly significant
contribution to improved safety. In modern
installations, high availability is becoming
increasingly important. The compact design
and high functionality of combined RCBOs
offer new opportunities for a modern, user-
friendly electrical installation. Comparing
conventional installations with installations
using RCBOs enables you to see the advan-
tages.
Conventional installation
With conventional electrical installations (see
Fig. 1), the incoming supply is routed via a
back-up fuse, such as a meter fuse. For the
subsequent RCCBs, several miniature circuit-
breakers are connected in series for each ex-
ternal conductor. The RCCB is responsible for
fault protection and also, in the case of rated
residual currents of up to 30 mA, additional
protection against dangerous shock currents
in the event of direct bodily contact. Up to
300 mA, fire protection against electrically-
ignited fires caused by earth faults is also pro-
vided. The miniature circuit-breaker prevents
conductors being damaged due to overload
or short-circuit. Once an earth fault in one of
the series-connected electric circuits has trig-
gered the RCCB, all other electric circuits, in-
cluding those which are fault-free, are iso-
lated from the supply. These devices cannot
be operated again until the fault has been
corrected. If an installation is designed in this
way, the following factors must be taken into
account:
B In order for the plant to be dimensioned
correctly in relation to the RCCB, you must
ensure that the RCCB is not overloaded by
load currents that are too high. To achieve
this, you must ensure that:
– the rated current of the upstream fuse is
not higher than the rated current of the
RCCB, or
– the sum of the rated currents of the over-
current protective devices connected in se-
ries after the RCCB does not exceed the rated
current of the RCCB, or
– the rated current of the RCCB is not ex-
ceeded for a long period by taking into ac-
count the demand factors of the connected
electric circuits.
B The single-pole miniature-circuit breakers
only isolate the external conductors from the
supply in the disabled state. The neutral con-
ductor remains conductive on the load side.
Installation using RCBOs
The compact RCBO unit combination, 1-pole
+ N version, facilitates a new installation
12 E-Installation 4-2005
Conventional installation using an RCCB andminiature circuit-breakers
Installation using combined RCBOs
Einspeisung
FI-Schutzschalter
≤300 mA
FI/LS30 mA
FI/LS30 mA
FI/LS30 mA
FI/LS30 mA
FI/LS30 mA
FI/LS30 mA
FI/LS30 mA
Einspeisung
LS LS LSLSLSLSLS
Erdfehler-strom
Erdfehler-strom
Inst
all
ati
on
Eq
uip
pe
me
nt
Technical data: RCBO 1+N, type A
• Rated current: 6 A to 40 A• Rated residual current:
10 mA, 30 mA, 300 mA• Miniature-circuit-breaker tripping
characteristic: B and C• Rated switching capacity:
6 kA and 10 kA• Discrimination class: 3
Sch
alt
er
&St
eck
do
sen
method: The incoming supply is still routed
via a back-up fuse (e.g., meter fuse, SHU
switch), but each individual electric circuit
now has its own RCBO. In the event of a fault,
only the affected electric circuit is disabled.
The RCBO is responsible for fault, fire and
line protection. This type of installation of-
fers numerous benefits to planners and
users:
B The rated current of the upstream over-
current protective device (e.g., meter fuse,
SHU switch) is not restricted by the subse-
quent rated current intensities of the RCBOs
E-Installation 4-2005 13
Inst
all
ati
on
Eq
uip
pe
me
nt
iLinks to the topic:www.siemens.de/betawww.siemens.de/beta-news
Contact: [email protected]
5SU1… RCBOs with rated switching capacities of 6 kA (left) and 10 kA (right)
New range of RCBOs
Tailor-made, combined protection
The new 5SU1... RCBOs, part of the Beta
range of built-in installation devices, is a com-
pact circuit-protection device, which com-
bines the protective functions of miniature
circuit-breakers and RCCBs in a single device.
This makes configuring and installing elec-
trical plant much easier. The user benefits
from a modern electrical installation with
high plant availability. An advantage of this
device type is the rear-mounted port for the
standard pin busbar, as found on miniature
circuit-breakers, which makes it much easier
to connect pin busbars and conductors at the
same time. It is easy to check whether the con-
necting lead has been mounted correctly. The
version for a rated switching capacity of 10
kA is also characterized by a particularly dis-
tinctive touch guard. The reach-round protec-
tion ensures that fingers are protected even in
the terminal area and when conductors are
connected. The devices can also be removed
from the standard mounting rail or released
from a busbar network without the need for a
tool. Proven add-on components from the
miniature-circuit-breaker range, such as aux-
iliary contact blocks, fault-signal contacts, un-
dervoltage releases, shunt releases, and re-
mote-controlled mechanisms, can be used,
meaning that the devices can be employed in a
wide range of applications, from those in resi-
dential buildings to those in non-residential
buildings and industry. n
(only factors such as conductor cross-section
and shutdown conditions, are decisive).
B The RCBO protects itself against overload,
thus making it impossible for an undesired
overload caused by load currents that are too
high to occur.
B In the event of an earth fault in an electric
circuit, as for a short-circuit or overload, only
the affected electric circuit is disabled. All er-
ror-free electric circuits remain live. Plant
availability remains high accordingly.
B The use of RCBOs for each electric circuit
meets the requirements of DIN 18015-2 (Elec-
trical installations in residential buildings -
Part 2: Nature and extent of minimum equip-
ment). In accordance with this standard, the
RCCBs should be assigned to the electric cir-
cuits in such a way that disabling one RCCB
does not cause all electric circuits to fail. Se-
lective RCCBs are exempt from this.
B With RCBOs (1-pole + N), the neutral con-
ductor is always switched at the same time.
This means that all poles of 1-phase loads are
isolated from the supply, providing optimum
safety against vagabond voltages in the dis-
abled state. n
Siem
ens
AG
Einfache Hand-habung: Deckelkann im geöff-neten Zustandfixiert werden
Zefa
The 5ST3 remote-controlled mechanism givesdirect access to the plant.
Stromversorgung für Wartungszwecke in Verteilern
Steckdosen 5TE6 8
Die Steckdosen 5TE6 8 für Verteilereinbau
runden das Beta-Spektrum ab. Sie sind so-
wohl ohne Deckel
für 55 mm Bau-
tiefe als auch mit
Deckel für 70 mm
Einbautiefe einsetzbar und nach den Stan-
dards VDE, CEE7, CEI und UL verfügbar.
Alle Steckdosen können mit einem Deckel
nachgerüstet werden. Der Deckel kann mit ei-
nem Winkel von mehr als 180 ° nicht nur ge-
öffnet, sondern auch fixiert werden. Durch
das Herausziehen der Scharniere bleibt der
Deckel im geöffneten Zustand stehen. Das hat
den Vorteil, dass die Geräte z. B. bei Service-
arbeiten problemlos und wenn nötig, nur mit
einer Hand gesteckt werden können. Die be-
rührungsgeschützten Anschlussklemmen L,
N und PE sind auf einer Seite der Steckdose
angebracht und erlauben so eine einfache
Montage. Der Anschluss erfolgt generell von
unten.
Die Steckdosen nach den Normen VDE,
CEE7, CEI und UL sind die für den Einsatz in
Deutschland, Belgien, Frankreich, Italien und
den USA geeignet. Sie sind in Schutzart IP20
ausgeführt. Die kompakte Bauweise beträgt
auch mit Deckel 2,5 TE.
Einer der Anwendungsbereich der Steck-
dosen 5TE6 8 ist die Stromversorgung von
Montagewerkzeugen oder Servicegeräten in
den Verteilern von Gebäuden und Schaltanla-
gen. Um sicherzustellen, dass bei Spannungs-
ausfall im Verteiler gearbeitet werden kann,
empfiehlt es sich hier, die betreffende Steck-
dose von der Einspeisung mit einer kurz-
schlussstromfesten Leitungsverlegung und
gesonderten Absicherung einzuspeisen. Wei-
terhin dienen die Steckdosen zum Anschluss
von steckerfertigen Kommunikationsgeräten
in Kommunikationsverteilern oder in pri-
vaten Anlagen für gelegentliche Nutzung für
Geräte mit Schwerstanlauf und gesonderter
Absicherung. n
14 E-Installation 4-2005
Siem
ens
AG
Siem
ens
AG
iLinks to the topic:www.siemens.de/betawww.siemens.de/beta-news
Contact: [email protected]
sta
lla
tio
n E
qu
ipp
em
en
t
The 5ST3 051 remote-controlled mechanism
for 5SM3-range RCCBs supplements the
range of remote-controlled mechanisms for
miniature circuit-breakers. Preferred loca-
tions of use for the mechanisms are spacious
operating sites, which are not always occu-
pied, such as water treatment plant or radio
stations, and automated plant for energy
and operation management. Using a re-
mote-controlled mechanism for the Beta cir-
cuit-protection devices provides the user
with direct and immediate access to the
plant even if it is remote or in a location that
is hard to reach, as well as fast restarts fol-
lowing a fault. Benefits: a reduction in both
the time required and costs involved. The
remote-controlled mechanism is operated
via a mechanical function switch. When in
Fast remote switching
Remote-controlled mechanism for RCCBs
the “OFF” position, the remote-controlled
mechanism is disabled and can also be locked.
“RC OFF” prevents remote switching and only
allows the RCCB to be operated manually. For
example, in the event of a service job, this en-
sures that illegal remote switching is pre-
vented. When in the “RC ON” position, “Re-
mote ON” and “Remote OFF" switching is
possible, as well as on-site operation. If a
fault is triggered, the connected RCCB and
remote-controlled mechanism handles
move to the OFF position. The switch may
only be restarted once any hazard has been
eliminated. Following shutdown, the user
also has to acknowledge this for the remote-
controlled mechanism by means of a RESET
(OFF) command. With its mounting depth of
70 mm, the remote-controlled mechanism
matches the Beta product range. The re-
mote-controlled mechanism can also be
equipped with 5ST301 auxiliary contact
blocks in order to signal the RCCB’s switch-
ing state. n
Das Zählerschrankprogramm Alpha ZS-400 wurde jetzt umWandlerschränke und Wand-lerschnellmontagebausätze(SMB) erweitert. Die aktuelleingeführten Typen habeneinen Bemessungsstrom von250 A. Es handelt sichdabei um drei Variantenfür Energie Baden-Würt-temberg (EnBW) undeiner Variante für dieMitteldeutsche EnergieAG (enviaM) und dieStadtwerke Leipzig. DesWeiteren wird es Versio-nen mit Bemessungsströ-men von 160 und 400 A geben.
Wandlerschränke und Wand-ler-SMB kommen dann zum Ein-satz, wenn eine 63-A-Direkt-messung vom VNB nicht mehrausreicht. Dies trifft vor allem fürkleinere bis mittlere Gewerbebe-triebe mit einem höheren Strom-bedarf zu, wie beispielsweise inBäckereien. Die neuen Wandler-schränke und SMB sind typge-
E-Installation 4-2005 15
iLinks to the topic:www.siemens.de/alpha
Contact: [email protected]
Po
we
r S
up
ply
& D
istr
ibu
tio
n
Das Programmder Wandler-schränke AlphaZS-400 wirdschrittweiseerweitert
rantiert dem Elektroinstallateur,dass alle eingebauten Teile, wieder Hochstromteil und die Mess-plätze, alle Anforderungen, hin-sichtlich Kurzschlussstromfes-
tigkeit sowie der zulässigenErwärmung erfüllen.Da die Wandler-Messsätzeauch als Schnellmontage-
bausätze angeboten wer-den, ist der Einbau in nor-
male Zählerschränke mög-lich. Messeinrichtungen für 63-A-Direktmessung und Wandlermes-sung können so in einem Schrankuntergebracht werden. Vorausset-
zung ist die Zustimmung des zu-ständigen VNB. Die Typenvielfaltwird je nach Bedarf weiter aus-gebaut. Zwei weitere Typen fürenviaM stehen kurz vor der Einfüh-rung. Typen für die HamburgischeElectricitäts-Werke AG (HEW), OVAG,die Mainova AG und die EnergieNord AG (e.dis) befinden sich inder Abstimmungsphase mit denVNB. Ziel ist es, mit den Alpha-Wandlerschränken die gesamtenAnforderungen der VNB in Deutsch-land abzudecken und somit einflächendeckendes Programm bun-desweit anzubieten. n
I201_12400
e .dis Nord
Rheinhessen AG
Versorgungs-
Mitteldeutschland
EAM
SÜWAG
Über-
landw.
Fulda
AG
Oberhess.Versorgungsbetr.
(OVAG)
AG
HEAG
EW.
Energie-Aktiengesellschaft
Stw.Eschwege
AG
VEW ENERGIE Aktiengesellschaft
RWE Energie AG
Westmecklenburgische
Energieversorgung AG
Stw. Kiel AG
EWE Aktiengesellschaft
Überlandwerk
Nord-Hannover AG Avacon
RWE Energie AG
RWEEnergie
KW.Heinsbg.
E.-Vers.
Stw. Lindau
Bewag
envia
SchleidenGmbH
Kraftvers.
KEVAG
RWE Energie AG
RWE Energie AG
EWV-Energ.-u. GEW Köln AG
Rhein-Wied AG
STAWAG
Wasser- Vers.
Kreis-
Lister- u.
Lennekw.
Stw.MünsterGmbH
Stw.Osnabr.AG
Stw. Bremen AG
TEAG
enviaM
Stw. Lübeck
HEW Hamburg AG
EW Dahlenbg. AG
KW BLEKEDE
Stw. Neumünster
Eletrizitätswerk
Rheingau
ÜWStw.Mainz Groß-Gerau
Stw.Wiesb. GmbH
EAM
E.-Vers.
Ffm.
GelnhausenStw
Offenbach AG
Kreisw.
ELEKTRO-
MARK
RWE
AVUWestd.
NLKL.-u.Düsseld. AG
Stw.
e .dis Nord
e .dis e .dis
ESAG
Kreisw.
VEW
Waldeck
e. onWestfalen Weser
Energie-
Aktiengesellschaft
Strom-versorgung
Stw.HannoverAG
OsthannoverGmbH
Avacon
Mitteldeutschland EAM
Städ. Werke
Stw.BielefeldGmbH
Kassel AG
Harzenergie
Stw. Braun- schweig
SWM
Pfalzwerke AG
Stw. Karlsr.
Stw.Mannh.AG
Stw. Saarbr.
O I EA G
RWENET AG
FES
Süwag EnergieBammertal
ENBWN-ERGIE
Thüga AG
Lech-
Elektrizitäts-werkeAG
KW HaagGmbH
Thüga
ÜW
Röhn
e.onBayern
RegionalleitungUnterfranken
Städt. W.
Semt-EWStw. Erding
zu Stw.
München
Stw.
EW Tegernsee
Gem.-W.Garmisch-Partenkirchen
AG
GmbH
RWE
ÜW
REWAG
ÜZ Wörth-
ÜW Cobg.Thüga
Stw.Augsburg
Fürsten-feldbruck
Altheim AG
EW Wörth/Donau
R. Heider & Co. KG
Schäftersheim
LülsfeldÜberlandzentrale
Stw Ulm/Neu-Ulm
GmbH
ÜWKrumbach
München
Stw.
EBTAÜW
EW ReutteGmbH
Allgäuer
Überlandw.VKW
VKW
e.onBayern
RegionalleitungOberfranken
N-ERGIE
e.onBayern
RegionalleitungOstbayern
e.onBayern
RegionalleitungOstbayern
e.onBayern
RegionalleitungOberbayern
EnBW undTAB 2000 gleiche VNB
Wandlerschränke Alpha ZS-400
Regional wandlungsfähig
Siem
ens
AG
In der Reihe der Sicherungsklem-men 8WA1… wird zum Schutzvon Steuerstromkreisen bei Kurz-schluss jetzt auch eine Variantefür Zoll-Sicherungseinsätze derBaugrößen 1/4 “ x 1 “ und 1/4 “x 1 1/4 “ mit Bemessungsstrom6,3A angeboten. Die Klemme istwahlweise für Spannung AC/DC24V bzw. AC 120V/DC 110V mitLeuchtdiode (LED) zum leich-teren Auffinden des fehlerhaftenSteuerstromkreises oder, span-nungsunabhängig, ohne LED er-hältlich. Das Angebot ist vorneh-mlich auf den amerikanischenMarkt und damit an exportorien-tierte OEMs gerichtet. Die Klem-me hat einen herausziehbarenund schwenkbaren Sicherungs-halter, sodass der Sicherungs-einsatz bequem, schnell und ge-
Neue Sicherungsklemmen 8WA1
Kurzschluss-Schutz mitZollsicherung
fahrlos zu wechseln ist. Der beid-seitige Schraubanschluss bietetPlatz für je zwei Leiter: feindrähtig2 x 0,75 mm2 bis 2 x 1,5 mm2 mitAder-Endhülse und eindrähtig2x1mm2 bis 2x2,5mm2. Es kön-nen auch Leiter mit unterschied-lichen Querschnitten am Doppel-anschluss sicher angeklemmtwerden. n
Siem
ens
AG
Reihenklemme 8WA fürZollsicherungseinsatz
prüft nach DIN EN 60 439-1 (VDE0660 Teil 500), DIN EN 60 439-3(VDE 0660 Teil 504) und, soweitzutreffend, VDE 0603-1. Dies ga-
Installationsverteiler als Zentrale für Kommunikationstechnik
Gut aufgehoben
16 E-Installation 4-2005
Po
we
r S
up
ply
& D
istr
ibu
tio
n
Neue N-/PE-Steckklemmen
Einfach einschieben
Die neuen N-/PE-Steckklemmenmit Push-in-Technik für die 1- bis4-reihigen Unterputzvarianten desKleinverteilers Simbox 63 bringtrund 20 Prozent Zeitersparnis beider Verdrahtung. Bei der innovati-ven Klemmtechnik werden mas-sive, abisolierte Leiter oder fein-drähtige Leiter mit gecrimpterAderendhülse einfach bis zum An-schlag in die Klemme gesteckt. EinWerkzeug ist nicht erforderlich.Damit herrscht nun im Kleinver-teiler Simbox 63 die gleiche Mon-tagephilosophie wie in den Zähler-schränken.
Durch PE- und N-Leiteranschlüs-se von 1,5 bis 4 mm2 können alleLeiterarten sicher und schnell an-geschlossen werden. Größere Lei-terquerschnitte bis 16 mm2 wer-den durch die bewährte Zugbügel-klemme zuverlässig verbunden.
Die neue Steckklemme bietetdeutlich mehr Klemmstellen alsvon der Norm für Kleinverteiler ge-fordert und erfüllt so den Wunschder Praktiker nach mehr Anschluss-klemmen.
Zusätzlich zu den in den Zäh-lerschränken Alpha ZS-400 sowieden Verteiler-Schnellmontage-
Steckklemmen für die Klein-verteiler Simbox 63 1- und 2-reihig (oben), für Simbox 633- und 4-reihig (unten)
bausätzen mit Reihenabstand125mm integrierten Steckklem-men ist auch eine Steckklemmemit getrenntem N-Potential lie-ferbar. Diese kann ebenfalls inZählerschränken und Alpha DIN-Verteilern eingesetzt werden,wenn eine Verdrahtung von zweiFehlerstromschutzschaltern in-nerhalb eines Verteilerfeldes ge-fordert ist.
Die Klemme ist ebenfalls mitder innovativen, zeitsparendenPush-in-Technik für eindrähtigeoder Leiter mit gecrimpter Ade-rendhülse ausgestattet. Es kön-nen jedoch auch mehr- und fein-drähtige Leiter konventionell mitSchraubendreher in diesen An-schlüssen montiert und demon-tiert werden.
Die 30 º-Schrägstellung derKlemme gewährleistet die guteZugänglichkeit des Verdrahtungs-raumes und ermöglicht damiteine schnelle und komfortableVerdrahtung. n
gen. Hinsichtlich der Abmessun-gen sind die Telekommunika-tionsfelder auf die Alpha DIN-In-stallationsverteiler abgestimmtund lassen sich mittels einer Auf-nahmevorrichtung leicht inte-grieren. Die Stromversorgung derTelekommunikationsgeräte er-folgt über Steckdosen, die im be-nachbarten Verteilerfeld einge-baut sind.
Auf Montageplatten mit Git-terstruktur werden die einzelnenGeräte bohrungslos mit Einlege-
Üblicherweise sind die Installa-tionseinrichtungen für die Kom-munikationstechnik wie Telefon-anschluss, ISDN und DSL, Fern-seh- und SAT-Verteiler mehr oderweniger übersichtlich im ganzenHaus verteilt. Durch den Einsatzvon Telekommunikationsfeldernim Installationsverteiler ergibtsich die Möglichkeit, neben derklassischen Installationstechnikauch die Kommunikations- undDatentechnik dort übersichtlichund gut geschützt unterzubrin-
Das Telekommunikationsfeld im Zählerschrank ist der ideale,zentrale Platz für die moderne Kommunikationstechnik
Siem
ens
AG
Siem
ens
AG
Der Wechselrichter ist das „Ge-hirn“ einer Photovoltaik-Anlage.Netzgebundene Wechselrichterwandeln nicht nur den Gleich-strom der Photovoltaikmodule innetzkonforme Wechselspannungum und speisen ihn ins öffentli-che Netz, sondern überwachenauch die gesamte Anlage. So wiedie Wechselrichter Sitop solar, diebeispielsweise in PV-Anlagen vonWohnhäusern eingesetzt werden,oder wie die Zentralwechselrich-ter Sinvert solar für PV-Kraftwerkeab 30 kVA. Die innovativen Wech-selrichter speichern alle relevan-ten Daten und liefern eine Viel-zahl zusätzlicher Informationen.Das Mastergerät von Sitop solarverfügt über einen Historienspei-cher, der die Messwerte und Da-ten der letzten 28 Tage abspei-chert. Darunter die DC-Spannungam Solarfeld, die aufgenommeneDC- und abgegebene AC-Leis-tung, der Tagesertrag und even-tuelle Fehlermeldungen. Auch dieGesamtdauer und -leistung seitAnlagenbetrieb wird kontinuier-lich erfasst. Über einen Taster amDisplay können alle Werte nach-einander abgerufen werden. We-sentlich komfortabler lässt sichdas allerdings über die Visualisie-rungs-Software Sitop solar log be-werkstelligen. Verschiedene Wer-te können gleichzeitig betrachtetund grafisch dargestellt werden.Der Einspeiseverlauf über denganzen Tag wird übersichtlich alsKurve abgebildet. n
www.siemens.de/sitop-solar-downloads
E-Installation 4-2005 17
iLinks to the topic:www.siemens.de/alphawww.siemens.de/sitop-solar
Contact:[email protected]
Verschiedenste Tagesmesswerte lassen sich mit Sitop solar logeinfach auswählen und anzeigen
Wechselrichter Sitop solar 2300
muttern und Schrauben befes-tigt. Die einfache und schnelleMontage macht auch das Er-weitern, den Austausch oderdas Umrüsten zu einem Kinder-spiel. Mit Alpha-Leitungshal-tern ist eine saubere und or-dentliche Leitungsführung si-chergestellt. Ab Herbst erwei-tern neue Telekommunikations-felder das bisherige Spektrum.Diese Schnellmontagebausätzeverfügen zusätzlich über eineAbdeckung für die fertig mon-tierten Geräte und Kabel. Pas-send zu den Abmessungen derVerteilerschränke, betragendie Höhen der Bausätze 900mm, 1050 mm, 1200 mm und1350 mm. n
Fernvisualisierung für Photovoltaik-Anlagen
Messwerte übersichtlichdargestellt
Po
we
r S
up
ply
& D
istr
ibu
tio
n
Siem
ens
AG
KNX/EIB all packed upNew Gamma training case gives a detailed insight into the world of KONNEX
The whole Gamma instabus world
in case format: Siemens has been
marketing this instabus-KNX/EIB
(now Gamma instabus) demonstra-
tion system for training and presenta-
tion purposes since 1995, and it has
come to be known in the industry as
the “EIB dollhouse.” Now, the Gamma
training case (GTC) has been adapted
to customers' new requirements and
many functions have been added to
it. Using the case, users can experi-
ence all the Gamma instabus modes
of operation, while taking up a
minimum of space.
All devices, displays and operator functions
have been arranged in a clearer manner and
can be reached from the front. The design
components (pushbuttons, switches, sensors,
and displays) are located on the panel, which
folds out to the right. They are grouped
around a model floor plan, which clearly
shows a living/dining area, a staircase and a
study. The system devices, such as the power-
supply unit, USB interface controller blocks
and actuators, are situated on an integrated
Alpha distribution board panel.
Standard equipment with variousfunctions
Even the basic version of the GTC has all the
features required for use in certified training,
including switching, dimming, and setting
lights to a specific value, moving blinds/shut-
ters, proportional control, central functions,
and alarm sensors. The N524 blind actuator is
used for blind control, with two electronic
simulations demonstrating the blinds’ hang-
ing height and opening angle. The bus cou-
pling units and application modules are also
mounted separately so that the application
modules do not have to be removed in order
to press the programming key.
Long-lasting and rugged
The developers were particularly anxious that
no, or as few as possible, mechanical and
other parts that are subject to wear were used,
in order to prevent malfunctions, particularly
during the blinds simulation. In place of the
mechanical parts, maintenance-free LEDs
demonstrate the corresponding function in
the model floor plan. The case itself is made
from impact-resistant material reinforced
with an aluminum frame and its trolley de-
sign ensures excellent mobility.
Various equipment versions
As well as the standard equipment version,
there is also a full version, which expands the
range of functions offered by the GTC. This
gives you the option of demonstrating how a
motion detector is activated, as well as the
heating and cooling simulation temperature
control. Conditional operations, alarms or
18 E-Installation 4-2005
Se
rvic
e&
Dia
log
ue
You can order the Gamma training case
from your regional sales coordinators:
• Standard version (E20001-Y2950-P400)
• Full version (E20001-Y2960-P400)
• Training version (E20001-Y2960-P400)
Further information:
Siemens AG, A&S ET S CSC
Siemensstr. 10
93055 Regensburg, Germany
Fax: +49 (0) 9 41 7 90-27 19
Siem
ens
AG
Links to the topic:www.siemens.de/installationstechnik
presence simulations and connecting to Eth-
ernet (LAN) can also be demonstrated. The
training version also contains a main-line
module, which is required for a certified
KNX/EIB training session. n
Sch
alt
er
&St
eck
do
sen
New KNX/EIB courses
Building on a solid basis
Se
rvic
e&
Dia
log
ue
iLinks to the topic:www.siemens.de/elektroinstallation –>Support –> Trainingwww.siemens.de/sitrain.de
Impressum
HerausgeberSiemens Aktiengesellschaft,Bereich Automation and Drives (A&D), Gleiwitzer Str. 555, 90475 Nürnberg
www.siemens.de/automation
Bereichsvorstand Helmut Gierse, Hannes Apitzsch, Dr. Peter Drexel, Anton S. Huber
Presserechtliche VerantwortungPeter Miodek
Verantwortlich für den fachlichen InhaltGabriele Felder
KonzeptionChristian Leifels
VerlagPublicis KommunikationsAgentur GmbH, GWACorporate Publishing ZeitschriftenPostfach 32 40, 91050 ErlangenTel.: 0 91 31 / 91 92-5 01Fax: 0 91 31 / 91 92-5 [email protected]
Redaktion: Robert Engelhardt
Layout: Herbert Haida
Schlussredaktion: Regina Severing
DTP: Doess, Nürnberg
Druck: Stürtz AG, Würzburg
E-Installation erscheint vierteljährlich
Auflage: 32.500
©2005 by Siemens Aktiengesellschaft München und Berlin. Alle Rechte vorbehalten.
Diese Ausgabe wurde auf Papier aus umweltfreundlichchlorfrei gebleichtem Zellstoff gedruckt.
ISSN 1438-2504
Die folgenden Produkte sind eingetragene Marken der Siemens AG:DELTA, GAMMA instabus, NEOZED, SIKUS, SIMARIS, SITOP,TOTALY INTEGRATED POWER
Wenn Markenzeichen, Handelsnamen, technische Lösungenoder dergleichen nicht besonders erwähnt sind, bedeutetdieses nicht, dass sie keinen Schutz genießen.
Die Informationen in diesem Heft enthalten lediglichallgemeine Beschreibungen bzw. Leistungsmerkmale, welche im konkreten Anwendungsfall nicht immer in derbeschriebenen Form zutreffen bzw. welche sich durchWeiterentwicklung der Produkte ändern können. Die gewünschten Leistungsmerkmale sind nur dannverbindlich, wenn sie bei Vertragsschluss ausdrücklichvereinbart werden.
IWI: iein
Bestellnummer: E20001-M3405-B100
Seit Anfang des Jahres müssen Installateure
mit zwei unterschiedlichen Regelwerken ar-
beiten, die sich teilweise überschneiden und
unterschiedliche Definitionen gleicher Begriffe
verwenden: Zum einen die berufsgenossen-
schaftliche Unfallverhütungsvorschrift „Elek-
trische Anlagen und Betriebsmittel“, die seit
Januar 2005 die Kurzbezeichnung BGV A3*
trägt, und zum anderen die Betriebssicher-
heitsverordnung, die auf einer EU-Richtlinie
beruht und 2002 in Kraft getreten ist. Hierzu
zwei Beispiele:
Die Betriebssicherheitsverordnung spricht
von einer „befähigten Person“, die Prüfungen
an elektrischen Anlagen und Betriebsmittel
vornehmen darf. Der Anlagenbetreiber kann
unter bestimmten Voraussetzungen entschei-
den, wer eine solche „befähigte Person“ ist. Die
BGV A3 will nur einer Elektrofachkraft oder
Berufsgenossenschaftliche Vorschrift BGV A3
Beratung tut Not
elektrotechnisch unterwie-
senen Person Prüfungen
zugestehen. Kommt es
zum technischen Versa-
gen, kann diese Begriffs-
definition zu rechtlichen
Problemen führen.
Der Anlagenbetreiber,
als zweites Beispiel, kann
Prüfungsfristen gemäß Be-
triebssicherheitsverord-
nung nach eigenem Er-
messen in bestimmten Be-
reichen verlängern. Zur
eigenen Sicherheit kann
der Installateur nicht da-
rauf vertrauen, dass der Betreiber automa-
tisch die richtige Entscheidung trifft. Im
Zweifelsfall wird heute vom Installateur eine
Beratungsleistung verlangt, die mit zusätz-
licher Verantwortung verbunden ist. Hier
bieten die BGV A3 sowie entsprechende VDE-
Vorschriften mit konkreten Angaben zu Prü-
fungen die größere Rechtssicherheit. Der
Installateur sollte den Betreiber hierauf auf-
merksam machen und ihn nach einer Gefah-
renanalyse dahingehend beraten. n
BGV A3: www.arbeitssicherheit.de
Betriebssicherheitsverordnung:
http://bundesrecht.juris.de/
bundesrecht/BMA_index.html
zefa
* In der Ausgabe 2/2005, S. 6, „Neue Neozed-Sicherungs-sockel mit Berührungsschutz nach BGV A2“ und inAusgabe 3/2005, S. 11, „Kurzschlussschutz pur“ wurdeversehentlich noch die alte Bezeichnung verwendet.
Building-management systems applicationsare becoming ever more advanced and mar-ket interest in them is growing. Someone whois aware of and uses these possibilities can beassured of new business opportunities. Weoffer support in this area in the form of train-ing courses on the latest trends and develop-ments, which are held in our training center inRegensburg and are based on KNX/EIB. Thecourses offered can also always be held at thecustomer’s premises on request - either inGerman or English. You can keep up to dateregarding the courses on offer, and registeronline, at any time via the new Sitrain portalat www.siemens.de/sitrain-et. n
instabus KNX/EIB basic course (G = German E = English)
ET-KNXBKDecember 12–16, 2005 G RegensburgJanuary 16–20, 2006 G RegensburgFebruary 13–17, 2006 G RegensburgMarch 13–17, 2006 E RegensburgMarch 20–24, 2006 G Regensburg
instabus KNX/EIB continuation courseET-KNXA1January 01–February 03, 2006 G Regensburg March 06–10, 2006 G Regensburg March 20–24, 2006 E Regensburg
KNX/EIB Web visualization – EIBnet/IPET-KNXVIPJanuary 24–26, 2006 G Regensburg