Upload
michael-padilla
View
53
Download
13
Embed Size (px)
Citation preview
EG - GSM Timer and BSCParameter Handling
DN9813203Issue 9-0 en
# Nokia Corporation 1 (18)
BSC3119Nokia BSC/TCSM, Rel. S12, ProductDocumentation, v.1
The information in this document is subject to change without notice and describes only theproduct defined in the introduction of this documentation. This document is intended for the useof Nokia's customers only for the purposes of the agreement under which the document issubmitted, and no part of it may be reproduced or transmitted in any form or means without theprior written permission of Nokia. The document has been prepared to be used by professionaland properly trained personnel, and the customer assumes full responsibility when using it.Nokia welcomes customer comments as part of the process of continuous development andimprovement of the documentation.
The information or statements given in this document concerning the suitability, capacity, orperformance of the mentioned hardware or software products cannot be considered binding butshall be defined in the agreement made between Nokia and the customer. However, Nokia hasmade all reasonable efforts to ensure that the instructions contained in the document areadequate and free of material errors and omissions. Nokia will, if necessary, explain issueswhich may not be covered by the document.
Nokia's liability for any errors in the document is limited to the documentary correction of errors.NOKIA WILL NOT BE RESPONSIBLE IN ANY EVENT FOR ERRORS IN THIS DOCUMENTOR FOR ANY DAMAGES, INCIDENTAL OR CONSEQUENTIAL (INCLUDING MONETARYLOSSES), that might arise from the use of this document or the information in it.
This document and the product it describes are considered protected by copyright according tothe applicable laws.
NOKIA logo is a registered trademark of Nokia Corporation.
Other product names mentioned in this document may be trademarks of their respectivecompanies, and they are mentioned for identification purposes only.
Copyright © Nokia Corporation 2007. All rights reserved.
2 (18) # Nokia Corporation DN9813203Issue 9-0 en
EG - GSM Timer and BSC Parameter Handling
Contents
Contents 3
List of tables 4
List of figures 5
Summary of changes 7
EG - GSM TIMER AND BSC PARAMETER HANDLING 9
EGO OUTPUT TIMERS/PARAMETERS 11
EGT MODIFY TIMER 13
EGP MODIFY PARAMETER 17
DN9813203Issue 9-0 en
# Nokia Corporation 3 (18)
Contents
List of tables
4 (18) # Nokia Corporation DN9813203Issue 9-0 en
EG - GSM Timer and BSC Parameter Handling
List of figures
DN9813203Issue 9-0 en
# Nokia Corporation 5 (18)
List of figures
6 (18) # Nokia Corporation DN9813203Issue 9-0 en
EG - GSM Timer and BSC Parameter Handling
Summary of changes
Changes between document issues are cumulative. Therefore, the latest documentissue contains all changes made to previous issues.
Changes made between issues 9 and 8V
EGO OUTPUT TIMERS/PARAMETERS
The execution printout was updated.
Editorial changes.
Changes made between issues 8V and 8
EGT MODIFY TIMER
Changed the explanation of 'time unit' as timers T3168 andT3192 have different ranges of values.
Changes made between issues 8 and 7 (6–1)
Changes due to new functionalities
EGO OUTPUT TIMERS/PARAMETERS
Two new timers (T3168, T3192) were added toEXECUTION PRINTOUTS.
EGT MODIFY TIMER
Two new timers (T3168, T3192) and their rules for timerunit guide were added to PARAMETEREXPLANATIONS.
One example about timer value guide for timer T3168 wasadded to EXAMPLES.
DN9813203Issue 9-0 en
# Nokia Corporation 7 (18)
Summary of changes
8 (18) # Nokia Corporation DN9813203Issue 9-0 en
EG - GSM Timer and BSC Parameter Handling
EG - GSM TIMER AND BSC PARAMETERHANDLING
With the commands of this command group you handle GSM timers and BSCparameters.
Menu of the command group:
GSM TIMER AND BSC PARAMETER HANDLING COMMANDS
? ..... DISPLAY MENU
O: ..... OUTPUT TIMERS/PARAMETERS
T: ..... MODIFY TIMER
P: ..... MODIFY PARAMETER
Z; ..... RETURN TO MAIN LEVEL
The commands in this command group are:
EGO OUTPUT TIMERS/PARAMETERS
EGT MODIFY TIMER
EGP MODIFY PARAMETER
DN9813203Issue 9-0 en
# Nokia Corporation 9 (18)
EG - GSM TIMER AND BSC PARAMETER HANDLING
10 (18) # Nokia Corporation DN9813203Issue 9-0 en
EG - GSM Timer and BSC Parameter Handling
EGO OUTPUT TIMERS/PARAMETERSFunction With the command EGO you print out the name, value, preset value, and type of
timers and parameters.
Parameters output category;
Syntax EGO: [ <output category> | <all> def ];
Parameterexplanations
output category
The parameter can have the following values:
TIM Displays timers.
PAR Displays parameters.
ALL Displays all timers and parameters.
The default value is all parameters and timers.
Examples 1. Display all timers and parameters.
ZEGO; or ZEGO:ALL;
2. Display timers.
ZEGO:TIM;
Additionalinformation
The command reads the value of the parameter from the BSC Control ParameterFile (PAFILE) and displays them on an output device.
Execution printouts The execution printout for example 2 is the following:
PRESET
PARAMETER VALUE VALUE MODIFIABLE
--------------------------------—--------------------------------
T4 60.00 S 60.00 S YES
T7 20.00 S 20.00 S YES
T8 12.00 S 12.00 S YES
T10 8.00 S 8.00 S YES
T13 15.00 S 15.00 S YES
DN9813203Issue 9-0 en
# Nokia Corporation 11 (18)
EGO OUTPUT TIMERS/PARAMETERS
T17 4.00 S 4.00 S YES
T18 12.00 S 12.00 S YES
T3101 3.00 S 3.00 S YES
T3103 6.00 S 6.00 S YES
T3105_D 0.28 S 0.28 S NO
T3105_F 0.10 S 0.10 S NO
T3107 6.00 S 6.00 S YES
T3109 12.00 S 12.00 S YES
T3111 0.50 S 0.50 S NO
T3121 12.00 S 12.00 S YES
T3122 6.00 S 6.00 S YES
T3168 1.00 S 1.00 S YES
T3192 0.50 S 0.50 S YES
T9101 10.00 S 10.00 S NO
T9103 2.00 S 2.00 S NO
T9104 15.00 S 15.00 S YES
T9105 10.00 S 10.00 S YES
T9108 2.00 S 2.00 S NO
T9113 13.00 S 13.00 S YES
TBBI 15.00 S 15.00 S YES
COMMAND EXECUTED
The values of all timers are displayed in seconds.
Semantic errormessages
If an error occurs, the general semantic error messages of MML commands areprinted out.
Execution errormessages
/*** READING PARAMETER FILE FAILED ***/
The MML is unable to read the parameter file.
12 (18) # Nokia Corporation DN9813203Issue 9-0 en
EG - GSM Timer and BSC Parameter Handling
EGT MODIFY TIMERFunction With the command EGT you modify the value of the timer.
Parameters timer name: time unit, timer value;
Syntax EGT: ( <timer name> ) :
[ <time unit> | 1 def] ,
( <timer value> ) ;
Parameterexplanations
timer name
The parameter indicates the timer which is to be modified.
The timer names comprises of 1-10 characters. The names of timers are listed inthe guidance texts.
The parameter is obligatory.
time unit
The parameter, given in a decimal format, indicates which time unit has beenused as a value.
The parameter can have the following values:
1 Value in seconds.
2 Value in 10 milliseconds.
The default value is seconds.
For timers T3168 and T3192, the timer unit is either seconds or milliseconds. Thevalues of these timers are decimal values which indicate the timer values from500 ms to 4 seconds for timer T3168 and from 500 ms to 1.5 seconds for timerT3192 every half second. In these cases, the parameter can have the followingvalues:
DN9813203Issue 9-0 en
# Nokia Corporation 13 (18)
EGT MODIFY TIMER
1 Value in seconds.
2 Value in milliseconds.
The default value is seconds.
timer value
The parameter, given in a decimal format, indicates the new value of the timer.The guidance text shows the name, current value, and value range of the timer inthe selected time unit.
Parts of seconds can only be given by using the 10 milliseconds time unit.
The parameter is obligatory.
Examples 1. Modify the value of T4 to 10 seconds.
ZEGT:T4:,10; or ZEGT:T4:1,10;
2. Modify the value of T3107 to 3.50 seconds.
ZEGT:T3107:2,350;
3. Output the guide for the timer value of timer T3168 in seconds.
ZEGT:T3168:1
/* IDENTIFY VALUE OF TIMER T3168
DECIMAL NUMERAL 0 ... 7
0 ... 0,5 s
1 ... 1,0 s
2 ... 1,5 s
3 ... 2,0 s
4 ... 2,5 s
5 ... 3,0 s
6 ... 3,5 s
7 ... 4,0 s
PARAMETERS CURRENT VALUE IS 1,0 S
PARAMETER IS OBLIGATORY */
Additionalinformation
After completion of semantic checks, the MML writes the value to the PAFILE. Ifthis is carried out successfully, the file is updated to the disks. After updating thefile, the file is distributed to other units. If these actions are not successfullycarried out, the previous value is applied and rewritten to the file.
Execution printouts
COMMAND EXECUTED
14 (18) # Nokia Corporation DN9813203Issue 9-0 en
EG - GSM Timer and BSC Parameter Handling
The MML has updated the new value of the timer to the file.
Semantic errormessages
If an error occurs, the general semantic error messages of MML commands areprinted out.
Execution errormessages
/*** MODIFYING FAILED ***/
The MML is unable to modify the timer. The reason for the failure is stored in thelog file of the system.
/*** STORING FAILED ***/
The MML is unable to store the value of the timer in the file.
/*** MCMU - 01 NOT UPDATED ***/
/*** BCSU - 02 NOT UPDATED ***/
/*** TRY AGAIN ***/
The units that have not updated the file are listed. You can re-enter the commandto update files to units.
DN9813203Issue 9-0 en
# Nokia Corporation 15 (18)
EGT MODIFY TIMER
16 (18) # Nokia Corporation DN9813203Issue 9-0 en
EG - GSM Timer and BSC Parameter Handling
EGP MODIFY PARAMETERFunction With the command EGP you modify the value of the parameter.
Parameters parameter number: parameter value;
Syntax EGP: ( <parameter number> ) : ( <parameter value> ) ;
Parameterexplanations
parameter number
The parameter indicates the parameter which is to be modified. The names of theparameters and the corresponding numbers are displayed on the output device.
The parameter is obligatory.
parameter value
The parameter indicates the new value of the parameter. The name of theparameter, its current value, and the range of the value are displayed.
The parameter is obligatory.
Examples 1. Modify the value of the first parameter to 1.
ZEGP:1:1;
2. Modify the value of the sixth parameter to 1.
ZEGP:6:1;
Additionalinformation
After completing semantic checks, the MML writes the value to the PAFILE. Ifthis is carried out successfully, the file is updated to the disks. After updating thefile, the file is distributed to other units. If these actions are not successfullycarried out, the previous value is applied and rewritten to the file.
Execution printouts COMMAND EXECUTED
The MML has updated the new value of the parameter to the file.
DN9813203Issue 9-0 en
# Nokia Corporation 17 (18)
EGP MODIFY PARAMETER
Semantic errormessages
If an error occurs, the general semantic error messages of MML commands areprinted out.
Execution errormessages
/*** MODIFYING FAILED ***/
The MML is unable to modify the parameter. The reason for the failure is storedin the log file of the system.
/*** STORING PARAMETER FAILED ***/
The MML is unable to store the value of the parameter in the file.
/*** MCMU - 01 NOT UPDATED ***/
/*** BCSU - 02 NOT UPDATED ***/
/*** TRY AGAIN ***/
The units that have not updated the file are listed. You can re-enter the commandto update files to units.
18 (18) # Nokia Corporation DN9813203Issue 9-0 en
EG - GSM Timer and BSC Parameter Handling