6
FULL LENGTH ARTICLE Effect of sulfide pollution on the stability of Cu–Al–5Ni alloy in 3.5% NaCl solution Nady H. El-Sayed * , Mohamed M. El-Rabiei Chemistry Department, Faculty of Science, Fayoum University, Fayoum, Egypt Received 18 April 2013; accepted 25 June 2013 Available online 11 June 2014 KEYWORDS Alloys; Corrosion; EIS; Sulfide Abstract The stability of Cu–Al–5Ni ternary alloy used in the manufacture of NaCl and Na 2 SO 4 from the Lake Qaroun in Egypt was investigated in 3.5% NaCl in the presence of sulfide ions. The electrochemical reactions of Cu–Al–5Ni electrode in the test solutions were studied using electro- chemical impedance spectroscopy measurements. In addition surface examination and morpholog- ical studies were applied using scanning electron microscopy (SEM) and energy dispersive analysis of X-rays (EDAX). The results of impedance measurements at open circuit potential have shown that the overall impedance of the system decreases with the increase in sulfide ion concentration and increases with immersion time due to continuous growth of the passive film on the alloy surface. The EDAX analysis showed the presence of copper, aluminum and nickel compounds, Cu-oxides, Cu-chlorides and Cu 2 S on the alloy surface. ª 2014 Production and hosting by Elsevier B.V. on behalf of Egyptian Petroleum Research Institute. 1. Introduction Copper and its alloys are highly corrosion resistant in chloride medium. This is why these materials are widely employed in industrial applications such as heat exchangers and electronic devices. The good corrosion resistance of these materials is due to two reasons. Firstly, in acidic medium, the standard potential of Cu|Cu (I) is more positive than the hydrogen evolution potential. The spontaneous corrosion potential of copper will therefore locate in the immunity region in the absence of dissolved oxygen [1]. Secondly, in neutral medium, a uniform and an adherent film formed at the metal surface by corrosion products acts as a barrier layer against the aggressive medium. In spite of this self-protective effect, copper and copper alloys might get damaged in different situations. For instance, in chloride medium, the corrosion properties of copper are markedly modified by the formation of copper– chloride complexes [2]. Deslouis et al. concluded that in 3% NaCl medium the corrosion current density is depending on the chloride concentration, potential and rotation speed of the electrode [3]. The presence of certain pollutants, such as sulfides or ammonia in the seawater may jeopardize cooling systems. In previous researches [4], the corrosion product formed on a copper surface in NaCl containing S 2 solution was studied. A single-layered compact Cu 2 S film, whose growth kinetics appeared to obey a parabolic law over an exposure period up to 1700 h. was formed once the compact film is established, its growth process is mainly controlled by * Corresponding author. Tel.: +20 1064941359. E-mail addresses: [email protected], [email protected] (N.H. El-Sayed). Peer review under responsibility of Egyptian Petroleum Research Institute. Production and hosting by Elsevier Egyptian Journal of Petroleum (2014) 23, 163168 Egyptian Petroleum Research Institute Egyptian Journal of Petroleum www.elsevier.com/locate/egyjp www.sciencedirect.com 1110-0621 ª 2014 Production and hosting by Elsevier B.V. on behalf of Egyptian Petroleum Research Institute. http://dx.doi.org/10.1016/j.ejpe.2014.05.002 Open access under CC BY-NC-ND license. Open access under CC BY-NC-ND license.

Effect of sulfide pollution on the stability of Cu–Al–5Ni alloy in … · 2017-01-17 · FULL LENGTH ARTICLE Effect of sulfide pollution on the stability of Cu–Al–5Ni

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Effect of sulfide pollution on the stability of Cu–Al–5Ni alloy in … · 2017-01-17 · FULL LENGTH ARTICLE Effect of sulfide pollution on the stability of Cu–Al–5Ni

Egyptian Journal of Petroleum (2014) 23, 163–168

Egyptian Petroleum Research Institute

Egyptian Journal of Petroleum

www.elsevier.com/locate/egyjpwww.sciencedirect.com

FULL LENGTH ARTICLE

Effect of sulfide pollution on the stability

of Cu–Al–5Ni alloy in 3.5% NaCl solution

* Corresponding author. Tel.: +20 1064941359.

E-mail addresses: [email protected], [email protected]

(N.H. El-Sayed).

Peer review under responsibility of Egyptian Petroleum Research

Institute.

Production and hosting by Elsevier

1110-0621 ª 2014 Production and hosting by Elsevier B.V. on behalf of Egyptian Petroleum Research Institute.

http://dx.doi.org/10.1016/j.ejpe.2014.05.002

Open access under CC BY-NC-ND license.

Open access under CC BY-NC-ND license.

Nady H. El-Sayed *, Mohamed M. El-Rabiei

Chemistry Department, Faculty of Science, Fayoum University, Fayoum, Egypt

Received 18 April 2013; accepted 25 June 2013

Available online 11 June 2014

KEYWORDS

Alloys;

Corrosion;

EIS;

Sulfide

Abstract The stability of Cu–Al–5Ni ternary alloy used in the manufacture of NaCl and Na2SO4

from the Lake Qaroun in Egypt was investigated in 3.5% NaCl in the presence of sulfide ions. The

electrochemical reactions of Cu–Al–5Ni electrode in the test solutions were studied using electro-

chemical impedance spectroscopy measurements. In addition surface examination and morpholog-

ical studies were applied using scanning electron microscopy (SEM) and energy dispersive analysis

of X-rays (EDAX). The results of impedance measurements at open circuit potential have shown

that the overall impedance of the system decreases with the increase in sulfide ion concentration

and increases with immersion time due to continuous growth of the passive film on the alloy

surface. The EDAX analysis showed the presence of copper, aluminum and nickel compounds,

Cu-oxides, Cu-chlorides and Cu2S on the alloy surface.ª 2014 Production and hosting by Elsevier B.V. on behalf of Egyptian Petroleum Research Institute.

1. Introduction

Copper and its alloys are highly corrosion resistant in chloridemedium. This is why these materials are widely employed inindustrial applications such as heat exchangers and electronic

devices. The good corrosion resistance of these materials isdue to two reasons. Firstly, in acidic medium, the standardpotential of Cu|Cu (I) is more positive than the hydrogen

evolution potential. The spontaneous corrosion potential of

copper will therefore locate in the immunity region in the

absence of dissolved oxygen [1]. Secondly, in neutral medium,a uniform and an adherent film formed at the metal surface bycorrosion products acts as a barrier layer against the aggressivemedium. In spite of this self-protective effect, copper and

copper alloys might get damaged in different situations. Forinstance, in chloride medium, the corrosion properties ofcopper are markedly modified by the formation of copper–

chloride complexes [2]. Deslouis et al. concluded that in 3%NaCl medium the corrosion current density is depending onthe chloride concentration, potential and rotation speed of

the electrode [3]. The presence of certain pollutants, such assulfides or ammonia in the seawater may jeopardize coolingsystems. In previous researches [4], the corrosion product

formed on a copper surface in NaCl containing S2� solutionwas studied. A single-layered compact Cu2S film, whosegrowth kinetics appeared to obey a parabolic law over anexposure period up to �1700 h. was formed once the compact

film is established, its growth process is mainly controlled by

Page 2: Effect of sulfide pollution on the stability of Cu–Al–5Ni alloy in … · 2017-01-17 · FULL LENGTH ARTICLE Effect of sulfide pollution on the stability of Cu–Al–5Ni

Table 1 Mass spectrometric analysis of the Cu–Al–5Ni alloy.

Cu Al Ni Zn Mn Sn Fe Si Mg

81.16 11.15 4.98 0.11 0.02 0.14 2.22 0.21 0.01

-2

0.5

1.0

1.5

2.0

2.5

3.0

log (f / Hz)

log

(Z /Ω

cm

2 )

-80

-60

-40

-20

0

20

3.5 % NaCl 3.5 % NaCl + 2 ppm S

2-

3.5 % NaCl + 5 ppm S2-

3.5 % NaCl + 10 ppm S2-

Phas

e / d

eg.

6420

Figure 1 Bode plots of Cu–Al–5Ni alloy after 1 h of immersion

in 3.5% NaCl solutions containing different sulfide ion concen-

trations at 25 �C.

164 N.H. El-Sayed, M.M. El-Rabiei

Cu+ diffusion in the film. However, the results of Smith et al.[5,6] showed that the properties of the sulfide film formed oncopper depend on the solution concentrations of both sulfide

and chloride.The good corrosion resistance of the Cu–Al–5Ni alloys in

neutral solutions is due to the presence of a protective layer

of alumina, which builds up quickly on the surface post-exposure to the corrosive environment and the passivationprocess is based on the fact that aluminum has a greater affin-

ity toward oxygen than copper and also on the considerablestability of Al2O3 than Cu2O in neutral solutions [7–9]. Theessential role of Ni in the passivation of Cu–Ni alloys has beenattributed to its incorporation into the Cu (I) oxide which is

formed as corrosion product [10]. The incorporation of nickelions reduces the number of cation vacancies that normallyexist in Cu (I) oxide [11]. The tremendous application of cop-

per/nickel alloys in different industries, where chloride con-taining water is always used, makes the understanding of theelectrochemical behavior of these alloys in the presence of

chloride ions and the control of the corrosion process impor-tant subjects worthy of intensive investigations. In this paperwe are aiming at the understanding of the effect of sulfide ions

as a pollutant in the stability of the Cu–Al–5Ni ternary alloysin 3.5% chloride solution.

2. Experimental details

The working electrodes were made from commercial gradeCu–Al–5Ni rod, mounted into glass tubes by two-componentepoxy resin leaving a surface area of 0.2 cm2 to contact the

solution The alloy was prepared in our metallurgical instituteand the mass spectrometric analysis of the electrode used ispresented in Table 1. The electrochemical cell was a three-

electrode all-glass cell, with a platinum counter electrode andsaturated calomel, SCE, reference electrode. Before eachexperiment, the working electrode was polished mechanically

using successive grades emery papers down to 2000 grit. Theelectrode was washed thoroughly with distilled water, andtransferred quickly to the cell. The electrochemical measure-

ments were carried out in a stagnant, naturally aerated 3.5%chloride solution containing different concentrations of sulfideions. The electrochemical impedance spectroscopic investiga-tions, EIS, were performed using a Voltalab PGZ 100

‘‘All-in-one’’ potentiostat/galvanostat. The potentials weremeasured against and referred to the standard potential ofthe SCE (0.245 V vs. the standard hydrogen electrode, SHE).

The total impedance, Z, and phase shift, h, were recorded inthe frequency domain 105–0.1 Hz. The superimposed ac-signalwas 10 mV peak to peak amplitude. The surface morphology

and the constituent elements of the passive film were investi-gated by SEM/EDAX (model ISPECT S 2006, FEI Company,Holland). Each experiment was carried out at least twice.

3. Results and discussion

3.1. Electrochemical impedance spectroscopy, EIS

EIS has been successfully applied to the study of corrosionsystems for 30 years and has been proven to be a powerful

and accurate method for measuring corrosion rates especiallyfor coatings and thin films. An important advantage of EIS

over other laboratory techniques is the possibility of using very

small amplitude signals without significantly disturbing theproperties being measured. The expression for impedance iscomposed of a real and an imaginary part. If the real part is

plotted on the z-axis and the imaginary part on the y-axis ofa chart, we get a ‘‘Nyquist plot’’. However, Nyquist plots haveone major shortcoming. When you look at any data point on

the plot, you cannot tell what frequency was used to recordthat point. Therefore, other impedance plots such as Bodeplots are important to make a correct interpretation. In Bodeplots, the impedance is plotted with log frequency on the x-axis

and both the absolute value of the impedance and phase-shifton the y-axis. Unlike the Nyquist plot, the Bode plot explicitlyshows frequency information. The impedance measurement

technique has been applied to the study of pitting corrosionand other localized corrosion [12–15]. The impedance tech-nique has marked advantages in the study of interfacial reac-

tions and other interfacial phenomena. The impedanceinformation obtained has time-resolved and surface character-istics [15]. In this work, the corrosion behavior of Cu–Al–5Ni

alloy, immersed in 3.5% NaCl solution containing differentsulfide concentrations was investigated.

Bode plots (Fig. 1) showed that the surface resistance of theCu–Al–5Ni alloy generally decreased by increasing the sulfide

ratio (2, 5 and 10 ppm of S2� in 3.5% NaCl, respectively). Thesamples showed dramatic decrease in the impedance in thecapacitive region, which is characteristic for the pitting process

on alloy. In addition, the phase angle (h) tends toward the lowfrequencies, indicating that the resistance of the barrier layerwas being approached. The changes of the spectra at very

low frequencies indicate the occurrence of pitting and werein agreement with visual and SEM inspections. On the otherhand, the samples tested in pure NaCl solution, without sulfide(blank), showed very stable impedance behavior, indicating

that the presence of sulfide ions in the solution negativelyaffects the protection performance of the passive oxide films.

Page 3: Effect of sulfide pollution on the stability of Cu–Al–5Ni alloy in … · 2017-01-17 · FULL LENGTH ARTICLE Effect of sulfide pollution on the stability of Cu–Al–5Ni

Figure 2 Equivalent circuit model used in the impedance data

fitting. Where Rs = solution resistance, Rct = charge-transfer

resistance, Cdl = double layer capacitance, Rpf = passive film

resistance, and Cpf = passive film capacitance.

Effect of sulfide pollution on the stability of Cu–Al–5Ni alloy in 3.5% NaCl solution 165

This would indicate that the sulfide ions interfere with the pro-

tective Cu oxide layer to form less protective layers of Cu oxideplus ion sulfide.

The development of more than one time constant is

deduced from the inspection of the spectra, which reflects thediversity of the phenomena, which occurs in the system underinvestigation. The equivalent circuit proposed to fit theexperimental data is shown in Fig. 2. It consists of electrolytic

solution resistance Rs connected with two time constants. Themodel is based on the circuits mostly used in the literature forsimulation of the kinetics of alloy corrosion process and the

protective properties of surface corrosion product layer [16–19].

The Bode plots of the alloy show two phase maxima, which

indicate the presence of two time constants representing theelectrode processes. The impedance data were analyzed usingthe Volta Master 4 software provided with the impedance sys-

tem where the dispersion formula was used. For a simpleequivalent circuit model consisting of a parallel combinationof a capacitor, Cdl, and a resistor, Rct, in series with a resistor,Rs, representing the solution resistance, the electrode imped-

ance, Z, is represented by the mathematical formulation:

Z ¼ Rs þRp

f1þ ð2pfRpCdlÞag

� �

where a denotes an empirical parameter (0 6 a 6 1) and f is thefrequency in Hz [20,21]. To account for the presence of a passive

film, the impedance data were analyzed using the equivalent cir-cuit model shown in Fig. 2 where another combination RpfCpf

representing the passive film resistance,Rpf, and the passive film

capacitance, Cpf, was introduced. The calculated equivalent cir-cuit parameters for the alloy at different concentrations of sul-fide ions are presented in Table 2. The time constant at the highfrequencies is originated from theRctCdl combination while that

at low frequencies is due to theRpfCpf combination. The passivefilm resistance,Rpf, decreased with increasing sulfide concentra-tions. The film resistance of Cu–Al–5Ni alloy in pure 3.5%

Table 2 Equivalent circuit parameters for the Cu–Al–5Ni in 3.5%

25 �C.

Con. of S2�/ppm Rs/X Rct/X cm2 Cdl/lF cm�

0 5.6 830 112.1

2 3.8 796 99.9

5 3.3 335.2 94.9

10 3.6 298.6 86.8

NaCl solution (Blank) is 1390 X cm2. The resistance decreased

to 853, 380, and 309 X cm2 after the addition of 2, 5, and10 ppm Na2S, respectively.

As shown in Fig. 1 the addition of sulfide at a concentration

as low as 2 ppm is sufficient to modify significantly the corro-sion behaviors of Cu–Al–5Ni alloy in 3.5% NaCl solution.The results presented in the following parts concern essentiallythis low pollution level. Fig. 3 presents the evolution of imped-

ance spectra in 3.5% NaCl in which 2 ppm of sulfide wasadded. The impedance data were recorded after different timeintervals of electrode immersion in the test solution. The calcu-

lated values of the equivalent circuit parameters of these mea-surements are summarized in Table 3. The phase angle of bodeplot changes with the time of alloy immersion in the solution.

The value of the phase angle especially that occurs at lower fre-quencies increases with the increase in the immersion time.This indicates a decrease in the corrosion rate which is reflectedon the increase in the film resistance, Rpf (cf. Table 3). Accord-

ing to Ostland and Alexander [22], the half-life time of sulfideat the concentration of 3.8 ppm in seawater saturated by airwas 20 min. The increase in Rpf may be explained partly by

the exhausting of sulfide ions, and partly by the formation ofcopper sulfide which protects copper against the corrosion.With accumulation of corrosion products, the surface rough-

ness increased leading to a higher Cf value. It is remarkableto see from the Nyquist plot (Fig. 4) that the diameters of semi-circles for the Cu–Al–5Ni alloy increase with the exposure

time, which suggests an increase in the charge transfer resis-tance or the oxide film resistance with time.

The corrosion and passivation behavior of the Cu–Al–5Nialloy can be explained on the basis of the data reported on Cu

and those of cast nickel–aluminum bronze [7,23,24]. The majoranodic process is the copper dissolution according to the fol-lowing equation.

Cuþ 2Cl� ! CuCl�2 þ e� ð1Þ

The cathodic process is actually the oxygen reductionaccording to:

O2 þ 2H2Oþ 4e� ! 4OH� ð2Þ

It was suggested that the presence of CuCl2� at the metal

surface leads to a hydrolysis reaction and the formation ofCu2O [3] according to:

2CuCl�2 þH2O! Cu2Oþ 4Cl� þ 2Hþ ð3Þ

In the ternary Al containing alloys an additional passiv-ation process is taking place in neutral solutions in which alayer of Al-oxide is formed as a result of the surface dissolution

of Al according to:

Alþ 4Cl� ! AlCl�4 þ e� ð4Þ

2AlCl�4 þ 3H2O! Al2O3 þ 6Hþ þ 8Cl� ð5Þ

NaCl solution containing different concentrations of sulfide at

2 a1 Rf/X cm2 Cf/lF cm�2 a2

0.99 1390 456.8 1.0

0.96 853.1 466.4 1.0

1.0 380.5 264.2 1.0

0.99 309.1 411.9 1.0

Page 4: Effect of sulfide pollution on the stability of Cu–Al–5Ni alloy in … · 2017-01-17 · FULL LENGTH ARTICLE Effect of sulfide pollution on the stability of Cu–Al–5Ni

0.5

1.0

1.5

2.0

2.5

3.0

3.5

3.5 % NaCl + 2 ppm S2-

30 min 60 min 90 min 120 min 180 min

log (f / Hz)

log

(Z /Ω

cm

2 )

-80

-60

-40

-20

0

20

Phas

e / d

eg.

-2 6420

Figure 3 Bode plots of Cu–Al–5Ni alloy after different times of

immersion in stagnant naturally aerated 3.5% NaCl + 2 ppm S2�

solution at 25 �C.

0.0 0.2 0.4 0.6 0.8 1.0

0.00

0.15

0.30

0.45

0.60

0.75 3.5 % NaCl + 2 ppm S2-

30 min 60 min 90 min 120 min 180 min

- Zi /

kΩ c

m2

Zr /kΩ cm2

Figure 4 Nyquist plots of Cu–Al–5Ni alloy after different times

of immersion in stagnant naturally aerated 3.5% NaCl + 2 ppm

S2� solution at 25 �C.

Figure 5 SEM micrograph of polished Cu–Al–5Ni alloy before

immersion in the test solution.

166 N.H. El-Sayed, M.M. El-Rabiei

The remarkably high corrosion resistance of the Cu–Al–5Nialloys is essentially due to the presence of a protective layer ofduplex nature containing both Cu2O and Al2O3 [25]. The inner

layer is an Al-rich barrier layer which is impermeable to Cu (I)cations preventing the dissolution of Cu from the alloy surface.The outer layer is a porous Cu-rich consisting mainly of Cu2O

passive film [26,27]. This result was confirmed by EDAX, wherethe surface shows higher concentration of Cu and also lowerconcentration of Ni due to Ni diffusion in the inner barrierlayer. Al is involved in the compact inner layer and its concen-

tration on the surface is slightly lower than the bulk. The duplexbarrier layer inhibits the ionic transport and hence an increasedcorrosion resistance can be recorded. Nickel ions are incorpo-

rated into the crystal lattice of Cu2O, as already reported byseveral authors [28,29] and the number of cation vacanciesdecreases with increasing nickel content [11]. Ni from the alloy

segregates into the Cu2O barrier layer via a solid state reactionand Ni2+ interacts with mobile cation vacancies which leads toa decrease in the ionic conductivity and increase in the elec-tronic conductivity of the barrier film and the corrosion resis-

tance thus increased [30].In sulfide containing solutions the sulfur may hydrogenate

to give HS� as follows [31–33];

S2� þH2O$ HS� þOH� ð6Þ

HS� will combine with metallic copper to form an adsorbed

precursor of oxidation reaction:

CuþHS� ! CuðHS�Þads ð7Þ

Then, the anodic dissolution of copper may take place:

CuðHS�Þ ! CuðHSÞ þ e� ð8Þ

Table 3 Equivalent circuit parameters for the Cu–Al–5Ni in 3.5%

Time/min. Rs/X Rct/X cm2 Cdl/lF cm�2

30 3.5 423 75.1

60 3.8 796 99.9

90 8.7 1129 112.7

120 5.1 1302 97.7

180 6.4 1563 64.3

Followed by the dissociation and the recombinationprocesses:

CuðHSÞ ! Cuþ þHS� ð9Þ

2Cuþ þHS� þOH� ! Cu2SþH2O ð10Þ

The overall reaction is therefore:

4Cuþ 2S2� þO2 þ 2H2O$ 2Cu2Sþ 4OH� ð11Þ

NaCl solution containing 2 ppm of sulfide ion at 25 �C.

a1 Rf/X cm2 Cf/lF cm�2 a2

0.99 433.4 367.1 1.0

0.96 853.1 466.4 1.0

1.0 1148 554.4 1.0

0.99 1321 602.1 1.0

1.0 1644 774.1 1.0

Page 5: Effect of sulfide pollution on the stability of Cu–Al–5Ni alloy in … · 2017-01-17 · FULL LENGTH ARTICLE Effect of sulfide pollution on the stability of Cu–Al–5Ni

Effect of sulfide pollution on the stability of Cu–Al–5Ni alloy in 3.5% NaCl solution 167

In parallel to these reactions, the cuprous oxide will also beformed (cf. Eq. (3)). However, the presence of Cu2S preventsdramatically the protective effectiveness of Cu2O film, so the

resistance of the passive film decreases by increasing the sulfideion concentration.

Under conditions of low (SH�) and high (Cl�), the forma-

tion of the soluble chloride complex, CuCl2�, by reaction with

the surface intermediate, Cu(SH�)ads, could compete with thefilm formation reaction [22]. While this would not be expected

to cause significant dissolution of copper. Dissolution as CuCl2-� via reaction (12), when (SH�) is low at the Cu alloy surface,could lead to the transport of Cu+ through pores to the Cu2S/solution interface, where (SH�) would be higher, and Cu2S

formation would occur via reaction (13). At the film/electrolyteinterface, reaction (13) would dominate:

CuðHS�Þads þ 2Cl� ! CuCl�2 þHS� ð12Þ

2CuCl�2 þHS� ! Cu2Sþ 4Cl� þHþ ð13Þ

Such a transport-deposition process would account for thefine particles, which nucleate and grow on the alloy surfaces atshort times.

3.2. Surface examinations

The surface morphology of the Cu–Al–5Ni alloy before andafter 5 h immersion in stagnant naturally aerated 3.5% NaCl

solution was investigated by SEM. The surface of the

Figure 6 (a) Scanning electron micrographs of Cu–Al–5Ni

alloys after 5 h immersion in naturally aerated 3.5% NaCl

solution at 25 �C. (b) EDAX analysis of the Cu–Al–5Ni alloys

after 5 h immersion in naturally aerated neutral 3.5% NaCl

solution at 25 �C.

Cu–Al–5Ni was subjected to EDAX analysis to record the dif-ferent constituents of the barrier layer. Figs. 5 and 6 show atypical SE micrograph of the polished alloy and after immer-

sion in 3.5% NaCl, where the corrosion sites are clearlyobserved. The EDAX analysis of the alloy after 5 h immersionin 3.5% NaCl showed that corrosion products at the surface of

Cu–Al–5Ni alloy were: 2.5% oxygen, 83.35% copper, 9% alu-minum, 3.75% nickel and 2% chlorine (wt%). It is likely thatthe corrosion products consist mainly of copper chloride and

Figure 7 (a and b) Scanning electron micrographs of Cu–Al–5Ni

alloy after 5 h immersion in naturally aerated 3.5%

NaCl + 2 ppm S2� solution at 25 �C. (c) EDAX analysis of the

Cu–Al–5Ni alloy after 5 h immersion in naturally aerated 3.5%

NaCl + 2 ppm S2� solution at 25 �C.

Page 6: Effect of sulfide pollution on the stability of Cu–Al–5Ni alloy in … · 2017-01-17 · FULL LENGTH ARTICLE Effect of sulfide pollution on the stability of Cu–Al–5Ni

168 N.H. El-Sayed, M.M. El-Rabiei

copper oxide, along with aluminum oxide and nickel incorpo-rated in these copper oxide/chloride surface layers [19,34]. Itseems that the upper layer of corrosion products consists

mainly of aluminum and nickel oxides and probably aluminumhydroxides and oxychloride complexes, while the inner layeralso contains copper, probably in the form of chloride or

oxide. In their corrosion research of Cu–Al–Ag alloy in NaClsolution, Benedetti et al. [34] have found that the exposure ofelectrodes to positive potentials leads to the formation of a

surface layer of hydrated aluminum oxide/hydroxide whichcompletely covers the CuCl layer and this could explain thelack of copper in the upper layer of corrosion products. Thecorrosion product formed after immersing the Cu–Al–5Ni

alloy in 3.5% NaCl + 2 ppm S2� solution was investigatedby SEM and EDAX and is shown in Fig. 7. The layer ofCuS is clear. SEM micrographs (Fig. 7), of electrode showed

severe pitting as well as crevice corrosion. Generally, coppersulfide and copper oxide (CuO) were detected in the surfacelayers of alloy. Microprobe analysis using EDAX (Fig. 7c),

revealed the constituent elements of the alloy itself beside theCl and S elements. This means that Cu2S, and CuCl2

� presentin the corrosion product.

4. Conclusion

The effect of sulfide on the corrosion of Cu–Al–5Ni alloy in

3.5% sodium chloride medium was examined by EIS measure-ments. The corrosion resistance of the Cu–Al–5Ni alloy in3.5% NaCl solutions decreases with the increase of the sulfideion concentration. Prolonged immersion of the alloy in the

solution passivates its surface due to the formation of anadherent barrier layer of duplex nature. Microstructures aftercorrosion demonstrated the occurrence of corrosion products

at the surface of Cu–Al–5Ni alloy. The EDAX analysesrevealed the presence of copper, aluminum and nickel oxides,chlorides and sulfide on the alloy surface.

References

[1] M. Pourbaix, Atlas d’́equilibre ´ electrochimique, Gauthiers-

Villard, 1963.

[2] G. Bianchi, P. Longhi, Corros. Sci. 13 (1973) 853–864.

[3] C. Deslouis, B. Tribillet, G. Mengoli, M.M. Musiani, J. Appl.

Electrochem. 18 (1988) 374–383.

[4] J. Chen, Z. Qin, D.W. Shoesmith, J. Electrochem. Soc. 157

(2010) 338–345.

[5] J.M. Smith, Z. Qin, D.W. Shoesmith, in: 17th International

Corrosion Congress, No. 3111, Las Vegas, NV, 2008.

[6] J. Smith, Z. Qin, F. King, L. Werme, D.W. Shoesmith,

Corrosion 63 (2007) 135–144.

[7] J.C. Scully, The Fundamentals of Corrosion, Pergamon Press,

Oxford, 1990.

[8] A. Schussler, H.E. Exner, Corros. Sci. 34 (1993) 1793–1802.

[9] W.A. Badawy, R.M. El-Sherif, H. Shehata, J. Appl.

Electrochem. 37 (2007) 1099–1106.

[10] R.F. North, M.J. Pryor, Corros. Sci. 10 (1970) 297–311.

[11] I. Milosev, M.H. Metikos, Electrochim. Acta 42 (1997) 1537–

1548.

[12] M. Orado, T. Okl, J. Light Met. 36 (1986) 416–421.

[13] J.L. Dawson, M.G.S. Ferreira, Corros. Sci. 26 (1986) 1009–

1026.

[14] F. Mansfeld, H. Shih, J. Electrochem. Soc. 135 (1988) 1171–

1172.

[15] P.Q. Zhang, J.X. Wu, W.Q. Zhang, X.Y. Lu, K. Wang, Corros.

Sci. 34 (8) (1993) 1343–1349.

[16] G. Cicileo, B. Rosales, F. Varela, J. Vilche, Corros. Sci. 41

(1999) 1359–1375.

[17] D. Zhang, L. Gao, G. Zhou, Appl. Surf. Sci. 225 (2004) 287.

[18] A. Srivastava, R. Balasubramaniam, Mater. Corros. 56 (2005)

611–618.

[19] W.A. Badawy, K.M. Ismail, A.M. Fathi, Electrochim. Acta 50

(2005) 3603–3608.

[20] K. Hladky, L.M. Calow, J.L. Dawson, Br. Corros. J. 15 (1980)

20–25.

[21] J. Hitzig, J. Titz, K. Juettner, W.J. Lorenz, E. Schmidt,

Electrochim. Acta 29 (1984) 287–296.

[22] H.E. Ostland, J. Alexander, J. Geophys. Res. 68 (1963) 3995–

3997.

[23] G. Kear, B.D. Barker, K.R. Stokes, F.C. Walsh, J. Appl.

Electrochem. 34 (2004) 659–669.

[24] G. Kear, B.D. Barker, K.R. Stokes, F.C. Walsh, J. Appl.

Electrochem. 34 (2004) 1235–1240.

[25] W.A. Badawy, M. El-Rabiee, N.H. Hilal, H. Nady,

Electrochim. Acta 56 (2010) 913–918.

[26] J.A. Wharton, R.C. Barik, G. Kear, R.J.K. Wood, K.R. Stokes,

F.C. Walsh, Corros. Sci. 47 (2005) 3336–3367.

[27] W.A. Badawy, M. El-Rabiee, N.H. Hilal, H. Nady,

Electrochim. Acta 55 (2010) 1880–1887.

[28] R.G. Blundy, M.J. Pryor, Corros. Sci. 12 (1972) 65–75.

[29] A.-M. Beccaria, J. Crousier, Br. Corros. J. 24 (1989) 49–52.

[30] M. Urquidi, D.D. Macdonald, J. Electrochem. Soc. 132 (1985)

555–558.

[31] V.F. Panasenko, Candidates Dissertation, Polytekh Inst, Kiev,

1972.

[32] M.R. Reda, J.N. Al Hajjaji, Br. Corros. J. 30 (1995) 56–62.

[33] J.M. Smith, Z. Qin, F. King, D.W. Shoesmith, in: Proc. Int.

Workshop on Sulfur Assisted Corrosion in Nuclear Waste

Disposal Systems, Brussels, Belgium, 2008, Oct 21–23, 2008.

[34] A.V. Benedetti, P.T.A. Sumodjo, K. Nobe, P.L. Cabot, W.G.