2
Communication PROFIBUS DP Master & Slave Modbus RTU Master & Slave (57,6 Kbit/s) Modbus TCP Master & Slave CUT (Ethernet TCP/UDP, RS485, RS232, RS422, SSI, CAN) Send & Receive TCP PROFINET Controller & Device and PROFIsafe Host & Device Part numbers/ delivery date Part numbers: 98 2200139: F 60 CPU 03 SILworX 98 2200497: F35 03 SILworX 98 2200498: F31 03 SILworX 98 2200496: F30 03 SILworX 98 2200469: F10 PCI 03 SILworX 89 4000025: HIMatrix SMR Delivery date: Immediately Enhanced performance – enhanced profitability The enhanced performance also allows the realisation of SMR functionalities (Sequence of Events, Multitasking and Reload). In conjunction with the available redundant safeethernet networking capability, many process applications can now be safeguarded even more efficiently and economically. System expansions or alterations for smaller applications using HIMatrix can now also be carried out online, guaranteeing maximum availability. Product News HIMatrix ® systems with enhanced performance Edition October 2011 | Page 1/2 Highlights Programmable with SILworX ® (at least V4.64) Minimum cycle time about 2 ms, the program is about 10 times faster than with the present HIMatrix More memory for program, data (5 MB in sum) More memory for CUT One licence for Multitasking, program Reload and Alarm&Events Up to 128 redundant safeethernet connections with up to 1,100 Byte data exchange Port-based VLAN support

Edition October 2011 Page 1/2 Pr oductNewsData transfer to other systems via OPC A&E Different HIMatrix systems can be synchronised via SNTP, or by using external time servers: decisions

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Edition October 2011 Page 1/2 Pr oductNewsData transfer to other systems via OPC A&E Different HIMatrix systems can be synchronised via SNTP, or by using external time servers: decisions

Communication

■■ PROFIBUS DP Master & Slave■■ Modbus RTU Master & Slave

(57,6 Kbit/s) ■■ Modbus TCP Master & Slave■■ CUT (Ethernet TCP/UDP,

RS485, RS232, RS422, SSI, CAN)

■■ Send & Receive TCP■■ PROFINET Controller & Device

and PROFIsafe Host & Device

Part numbers/ delivery date

Part numbers:■■ 98 2200139: F 60 CPU 03

SILworX■■ 98 2200497: F35 03 SILworX■■ 98 2200498: F31 03 SILworX■■ 98 2200496: F30 03 SILworX■■ 98 2200469: F10 PCI 03

SILworX■■ 89 4000025: HIMatrix SMR

Delivery date:Immediately

Enhanced performance – enhanced profitability The enhanced performance also allows the realisation of SMR functionalities (Sequence of Events, Multitasking and Reload). In conjunction with the available redundant safeethernet networking capability, many process applications can now be safeguarded even more efficiently and economically. System expansions or alterations for smaller applications using HIMatrix can now also be carried out online, guaranteeing maximum availability.

ProductNewsHIMatrix® systems with enhanced performance

Edition October 2011 | Page 1/2

Highlights

■■ Programmable with SILworX® (at least V4.64)

■■ Minimum cycle time about 2 ms, the program is about 10 times faster than with the present HIMatrix

■■ More memory for program, data (5 MB in sum)

■■ More memory for CUT■■ One licence for Multitasking,

program Reload and Alarm&Events

■■ Up to 128 redundant safeethernet connections with up to 1,100 Byte data exchange

■■ Port-based VLAN support

Page 2: Edition October 2011 Page 1/2 Pr oductNewsData transfer to other systems via OPC A&E Different HIMatrix systems can be synchronised via SNTP, or by using external time servers: decisions

F60 CPU 03 Add. 4 port switch 100 Base-Tx with safeethernet, SIL 3/Cat. 4/PL e

F35 0324 digital and 8 analog inputs, 2 counter inputs, 8 digital outputs, add. 4 port-switch 100 Base-Tx with safeethernet, SIL 3/Cat. 4/PL e

F31 0320 digital inputs configurable with line control, 8 digital outputs, add. 4 port-switch 100 Base-Tx with safeethernet, SIL 3/Cat. 4/PL e

F30 0320 digital inputs configurable with line control, 8 digital outputs, add. 4 port-switch 100 Base-Tx with safeethernet, SIL 3/Cat. 4/PL e

F10 PCI 03Integrated 4 port-switch 100 Base-Tx and safeethernet SIL 3/Cat.4/PL e, enhanced performance

HIMatrix SMR

Licence for the use of Sequence of Event Recording (SOE), Multitasking and Reload in HIMatrix with enhanced performance

96

90

00

520

1011 V

01 ©

by HIM

A P

aul H

ildeb

rand

t Gm

bH

+ C

o K

G H

IMax, H

IMatrix an

d S

ILwo

rX are reg

istered trad

emarks of H

IMA

Pau

l Hild

ebran

dt G

mb

H +

Co

KG

www.hima.com I [email protected]

Redundant safeethernet

■■ 2 MAC-addresses are available for Ethernet access, one for the CPU one for the COM. Therefore 2 individual IP addresses can be assigned

■■ CPU and COM have direct communication access to the Switch

■■ To build two independent networks it is possible to configure the Switch with VLAN functionality. E.g. network 1: Port 1 and 4 with the COM, network 2: Port 2 and 3 with the CPU

Possible structures:

Full redundant networks can now be set up with or without HIMax®.

The technical data for I/O is exactly the same as with the present HIMatrix product. HIMA will have both versions (present and enhanced performance) available in future.

ProductNews | HIMatrix with enhanced performance

Edition October 2011 | Page 2/2

Port 4

Port 1

COM

Port 3

Port 2

CPU

HIMaxHIMax

Network

HIMaxHIMax

One licence for all SMR functionalities: Sequence of Event Recording, Multitasking and Reload

Sequence of Event RecordingBenefit: You will find the cause of faults more quickly and be able to resolve them faster.■■ Event recording in the CPU, with the cycle time■■ Up to 4,000 different events per system can be defined, up to 500 events can be stored■■ Data transfer to other systems via OPC A&E■■ Different HIMatrix systems can be synchronised via SNTP, or by using external time

servers: decisions can be made on the same time basis even if the system is spread out over long distances

MultitaskingBenefit: With its multitasking capacity, the HIMatrix system increases efficiency.■■ Up to 32 independent user programs per system■■ Each program has its own safety-related checksum■■ Use of individual programs with their own cycle times■■ Integration of slower and time critical areas (e.g. burner management system/turbo

machinery control)■■ Fixed cycle times are possible for every application

ReloadBenefit: Most profitable where continuous processes are required.■■ The application program can be updated without disrupting the application

that is operating ■■ No unwanted changes: program modifications only on the basis of the already

loaded program ■■ For security: “reload deactivation“ can be used to block the reload