ECS65 - ECS130 · xppower.com 2 InputCharacteristics Characteristic Minimum Typical Maximum Units Notes&Conditions InputVoltage-Operating 80 115/230 275 VAC Derateoutputpower

  • Upload
    others

  • View
    10

  • Download
    1

Embed Size (px)

Citation preview

Page 1: ECS65 - ECS130 · xppower.com 2 InputCharacteristics Characteristic Minimum Typical Maximum Units Notes&Conditions InputVoltage-Operating 80 115/230 275 VAC Derateoutputpower

ECS65 - ECS130

• Page 2 - ECS65

• Page 13 - ECS100

• Page 24 - ECS130

Page 2: ECS65 - ECS130 · xppower.com 2 InputCharacteristics Characteristic Minimum Typical Maximum Units Notes&Conditions InputVoltage-Operating 80 115/230 275 VAC Derateoutputpower

ECS65 Series

• IT & Medical Safety Approvals

• <0.5 W Standby Power

• 65 W Convection Cooled Rating

• Industry Standard 2.0” x 4.0” x 1.05” Format

• Low Earth Leakage Current

• Class B Radiated Emissions (-B models)

• Low Temperature Operation

• 3 Year Warranty

The ECS65 Series has been designed to minimise the no load power consumption (<0.5 W) and maximise efficiency in order tofacilitate equipment design to the latest environmental legislation.

Approved for Class I applications, the ECS65 range of single output AC-DC, 65 W power supplies feature high power density in anindustry standard 2 x 4" (51.0 mm x 102.0 mm) footprint. The 1.05" (27.0 mm) high, 1U compatible high-density power suppliesmeet EN55022 Level B emissions with low earth leakage currents of 110 µA at 115 VAC or 210 µA at 230 VAC. Making theseswitchers ideal for industrial, IT and medical applications.

The ECS65 series has single output versions from 12 V to 48 VDC which are adjustable by ±10%. They are dual-fused for compliancewith IEC60601-1 and with typical efficiencies at 88%, minimal waste heat is generated. The ECS65 delivers a full 65 W of power up to+50 °C and operates at up to +70 °C with derating.

Page 3: ECS65 - ECS130 · xppower.com 2 InputCharacteristics Characteristic Minimum Typical Maximum Units Notes&Conditions InputVoltage-Operating 80 115/230 275 VAC Derateoutputpower

xppower.com

2

Input CharacteristicsCharacteristic Minimum Typical Maximum Units Notes & Conditions

Input Voltage - Operating 80 115/230 275 VAC Derate output power < 90 VAC. See fig. 1

Input Frequency 47 50/60 400 Hz Agency approval 47-63 Hz

Power Factor >0.5230 VAC, 100% loadEN61000-3-2 class A compliant

Input Current - No Load 0.02/0.03 A 115/230 VAC

Input Current - Full Load 1.0/0.6 A 115/230 VAC

Inrush Current 40 A 230 VAC cold start, 25 ºC

No Load Input Power 0.4 0.5 W

Earth Leakage Current110/210 260 µA 115/230 VAC/50 Hz (Typ.), 264 VAC/60 Hz (Max.)

0.7/1.5 mA 115/230 VAC/400 Hz

Input Protection T3.15A/250 V internal fuse in both line and neutral

Output CharacteristicsCharacteristic Minimum Typical Maximum Units Notes & Conditions

Output Voltage - V1 12 48 VDC See Models and Ratings table

Initial Set Accuracy ±1 % 50% load, 115/230 VAC

Output Voltage Adjustment ±10 % Via potentiometer. See mech. details (page 9)

Minimum Load 0 A

Start Up Delay 1 s 230 VAC full load (see fig.2)

Hold Up Time 16 ms 115 VAC full load (see fig.3)

Drift ±0.2 % After 20 min warm up

Line Regulation ±0.5 % 90-264 VAC

Load Regulation ±1 % 0-100% load.

Transient Response - V1 4 %Recovery within 1% in less than 500 µsfor a 50-75% and 75-50% load step

Over/Undershoot - V1 5 % See fig.4

Ripple & Noise 1 % pk-pk 20 MHz bandwidth (see fig.5 & 6)

Overvoltage Protection 115 140 % Vnom DC.

Overload Protection 110 160 % I nom Auto reset (see fig.7)

Short Circuit Protection Continuous, trip & restart (hiccup mode)

Temperature Coefficient 0.05 %/˚C

Overtemperature Protection °C Not fitted

Models and Ratings

Notes:1. For Class B radiated emissions models, add suffix -B to model number. For covered versions, add suffix ‘-C’ to model number or order part no. ECM40/60 COVERKIT for standalone cover. Derate output power by 20% with cover. The cover is not suitable for Class II installations.

Output Power - Convection Cooled Output Voltage V1 Max Output Current Model Number(1)

65 W 12.0 VDC 5.4 A ECS65US1265 W 15.0 VDC 4.3 A ECS65US1565 W 18.5 VDC 3.4 A ECS65US1865 W 24.0 VDC 2.7 A ECS65US2465 W 28.0 VDC 2.3 A ECS65US2865 W 48.0 VDC 1.4 A ECS65US48

Page 4: ECS65 - ECS130 · xppower.com 2 InputCharacteristics Characteristic Minimum Typical Maximum Units Notes&Conditions InputVoltage-Operating 80 115/230 275 VAC Derateoutputpower

xppower.com

3

Start Up Delay From AC Turn OnFigure 2Start up example from AC turn on(230 VAC, 270 ms)

Hold Up Time From Loss of AC

Figure 3Hold up example at 65 W loadwith 115 VAC input (20.1 ms)

Input Voltage Derating

Figure. 1

40

50

80

60

70

90

100

80 9085 275

Input Voltage (VAC)

Out

put

Pow

er(%

)

Page 5: ECS65 - ECS130 · xppower.com 2 InputCharacteristics Characteristic Minimum Typical Maximum Units Notes&Conditions InputVoltage-Operating 80 115/230 275 VAC Derateoutputpower

Output Ripple & Noise

Figure 5ECS65US12 (65 W)96 mV pk-pk ripple. 20 MHz BW

xppower.com

4

Typical Output Overshoot

Figure 4Typical Output Overshoot(ECS65US12, 230 VAC)

Page 6: ECS65 - ECS130 · xppower.com 2 InputCharacteristics Characteristic Minimum Typical Maximum Units Notes&Conditions InputVoltage-Operating 80 115/230 275 VAC Derateoutputpower

Output Ripple & Noise cont.

Figure 6ECS65US24 (65 W)112 mV pk-pk ripple. 20 MHz BW

xppower.com

5

Output Overload Characteristic

Figure 7Typical OverloadCharacteristic(ECS65US12 shown)

0

2

4

6

8

10

12

14

0 1 2 3 4 5 6 7

Output Current (A)

Out

put

Volts

(V)

Output entersTrip & Restart Mode

Page 7: ECS65 - ECS130 · xppower.com 2 InputCharacteristics Characteristic Minimum Typical Maximum Units Notes&Conditions InputVoltage-Operating 80 115/230 275 VAC Derateoutputpower

xppower.com

Xxxxxxxxxx

6

General Specifications

Characteristic Minimum Typical Maximum Units Notes & Conditions

Efficiency 88 % Full load (see fig.8 & 9)

Isolation: Input to OutputInput to GroundOutput to Ground

4000 VAC

1500 VAC

500 VDC

Switching Frequency 65 kHz

Power Density 7.7 W/in3

Mean Time Between Failure 850 kHrs MIL-HDBK-217F, Notice 2 +25 °C GB

Weight 0.28 (125) lb (g)

Efficiency Versus Load

85%

65%

60%

75%

80%

90%

0% 20% 40% 60% 80% 100%

% of Output Load

Effic

ienc

y

115VAC230VAC

70%

65 %

75%

80%

90%

0% 20% 40% 60% 80% 100%

% of Output Load

Effic

ienc

y 115VAC230VAC

85%

Figure 8 - ECS65US12

Figure 9 - ECS65US24

Page 8: ECS65 - ECS130 · xppower.com 2 InputCharacteristics Characteristic Minimum Typical Maximum Units Notes&Conditions InputVoltage-Operating 80 115/230 275 VAC Derateoutputpower

xppower.com

Xxxxxxxxxx

7

EnvironmentalCharacteristic Minimum Typical Maximum Units Notes & Conditions

Operating Temperature -20 +70 ºCDerate linearly from +50 ºC at 2.5%/ºCto 50% at 70 ºC. (See fig.10 & ThermalConsiderations)

Storage Temperature -40 +85 ºC

CoolingConvection CooledSee fig.10 & Thermal Considerations

Humidity 5 95 %RH Non-condensing

Operating Altitude 3000 m

Shock3 x 30 g/11 ms shocks in both +ve & -vedirections along the 3 orthogonal axis,total 18 shocks.

Vibration Three axis 5-500 Hz at 2 g x 10 sweeps

Electromagnetic Compatibility - Immunity

Phenomenon Standard Test Level Criteria Notes & Conditions

Low Voltage PSU EMC EN61204-3 High severity level as below

Harmonic Current EN61000-3-2 Class A

Radiated EN61000-4-3 3 A

EFT EN61000-4-4 3 A

Surges EN61000-4-5 Installation class 3 A

Conducted EN61000-4-6 3 A

Dips and Interruptions

EN61000-4-11

Dip: 30% 10 ms A

Dip: 60% 100 ms B

Dip: 100% 5000 ms B

EN60601-1-2

Dip: 30% 500 ms A

Dip: 60% 100 ms ALoad derating with 115 VAC input (typically80% derate dependant on model & load)

Dip: 100% 10 ms A

Int.: >95% 5000 ms B

Figure 10

Derating Curve

70

40

50

80

60

70

90

100

-20 5040 60

Ambient Temperature (ºC)

With Cover

Open Frame

Out

put

Pow

er(%

)

30

Page 9: ECS65 - ECS130 · xppower.com 2 InputCharacteristics Characteristic Minimum Typical Maximum Units Notes&Conditions InputVoltage-Operating 80 115/230 275 VAC Derateoutputpower

xppower.com

8

Electromagnetic Compatibility - Emissions

Phenomenon Standard Test Level Criteria Notes & Conditions

Conducted EN55011/22 Class B See fig. 11

Radiated EN55011/22Class A

Class B ECS65-B models

Voltage Fluctuations EN61000-3-3

Safety Agency Approvals

.15 1 10 30

-10

0

10

20

30

40

50

60

70

80

MHz dBµV

PMM 8000 PLUS Name: Last Date: 01/05/10 Time: 08:08

Limit #1: 55022bqp Limit #2: 55022bav Detector: Average

Figure 11Typical conductednoise plot

Typical EMC Plot

Safety Agency Safety Standard Category

CB Report UL US/15901/UL IEC60950-1:2005 Ed 2 Information Technology

UL UL File #139109 UL60950-1 (2007), CSA 22.2 No.60950-1-07 Ed 2 Information Technology

TUV TUV Certificate # B 10 11 57396 082, EN60950-1:2006 Information Technology

CE LVD

Safety Agency Safety Standard Category

CB Report Certificate #US/17857/UL, IEC60601-1 Ed 3 Including Risk Management Medical

UL UL File # E146893, ANSI/AAMI ES 60601-1:2005 & CSA C22.2 No. 60601-1:08 Medical

TUV EN60601-1:2006 Medical

Equipment Protection Class Safety Standard Notes & Conditions

Class I (& Class II, B Models) IEC60950-1:2005 Ed 2 & IEC60601-1 Ed 3See safety agency conditions ofacceptibility for details

Means of Protection Category

Primary to Secondary 2 x MOPP (Means of Patient Protection)

IEC60601-1 Ed 3Primary to Earth 1 x MOPP (Means of Patient Protection)

Secondary to Earth 1 x MOPP (Means of Patient Protection)

Page 10: ECS65 - ECS130 · xppower.com 2 InputCharacteristics Characteristic Minimum Typical Maximum Units Notes&Conditions InputVoltage-Operating 80 115/230 275 VAC Derateoutputpower

Mechanical Details

xppower.com

9

Notes1. All dimensions in inches (mm).Tolerance .xx = ±0.02 (0.50); .xxx = ±0.01 (0.25)

2. Weight: 0.28 lbs (125 g) & with cover 0.66 lbs (300 g)

Input Connector Output Connector

0.25 (0.6) GroundFaston Terminal

4.49 (114.0)

2.52(64.0)

1.54(39.0) 2 x M3 x 0.5 THD

0.16 (4.0)Max Screw Penetration

0.807(20.50)

4.055 (103.00)

0.22(5.5)

0.79(20.0)

4 x M3 x 0.5 THD0.16 (4.0) Max Screw Penetration

4.055 (103.00)

0.984(25.00)

0.22(5.5)

0.20 (5.1)

1.05(26.7)

0.14 (3.5)SMD Component Height

2.00 (50.8)

0.95 (24.1)

0.125 (3.18)

1.75 (44.45)J1

0.96 (24.5)

0.20 (5.1)

J2

4.00 (101.6)

0.125 (3.17) 3.750 (95.25)

C5

C4

T1

Q1

0.25 Faston Ground Tab

4 X ø.156 (3.96) Mounting Holesø.312 (7.92) Clearance top and bottom

4

11

2

J1 mates with Molex HousingPN 09-50-1031, J2 mates withMolex Housing PN 09-50-1041 and both with MolexSeries 5194 Crimp Terminals

Input Connector J1Molex PN 09-65-2038Pin 1 LinePin 2 Neutral

0.25” Faston Earth

Output Connector J2Molex PN 09-65-2048Pin 1 +V1Pin 2 +V1Pin 3 RTNPin 4 RTN

Page 11: ECS65 - ECS130 · xppower.com 2 InputCharacteristics Characteristic Minimum Typical Maximum Units Notes&Conditions InputVoltage-Operating 80 115/230 275 VAC Derateoutputpower

xppower.com

Xxxxxxxxxx

10

Thermal Considerations

In order to ensure correct and reliable operation of the PSU in the most adverse conditions permitted in the end-use equipment, the temperature of thecomponents listed in the table below must not be exceeded. See drawing on page 9 for component locations. Temperature should be monitored usingK type thermocouples placed on the hottest part of the component (out of any direct air flow).

Temperature Measurements (Ambient ≤ 50 °C)Component Max Temperature º C

T1 110 ºC

C5 100 ºC

C4 100 ºC

Q1 110 ºC

Page 12: ECS65 - ECS130 · xppower.com 2 InputCharacteristics Characteristic Minimum Typical Maximum Units Notes&Conditions InputVoltage-Operating 80 115/230 275 VAC Derateoutputpower

www.xppower.comwww.xppower.com

North American HQ

XP Power990 Benecia Avenue, Sunnyvale, CA 94085Phone : +1 (408) 732-7777Fax : +1 (408) 732-2002Email : [email protected]

European HQ

XP PowerHorseshoe Park, Pangbourne, Berkshire, RG8 7JWPhone : +44 (0)118 984 5515Fax : +44 (0)118 984 3423Email : [email protected]

German HQ

XP PowerAuf der Höhe 2, D-28357 Bremen, GermanyPhone : +49 (0)421 63 93 3 0Fax : +49 (0)421 63 93 3 10Email : [email protected]

Asian HQXP Power401 Commonwealth Drive, Haw Par Technocentre,Lobby B #02-02, Singapore 149598Phone : +65 6411 6900Fax : +65 6741 8730Email : [email protected] : www.xppowerchina.com /

www.xppower.com

North American Sales OfficesToll Free ....................+1 (800) 253-0490Central Region ..........+1 (972) 578-1530Eastern Region .......+1 (973) 658-8001Western Region ........+1 (408) 732-7777

European Sales OfficesAustria....................+43 (0)1 41 63 3 08Belgium.................+33 (0)1 45 12 31 15Denmark ......................+45 43 42 38 33Finland ...................+46 (0)8 555 367 01France ..................+33 (0)1 45 12 31 15Germany ...............+49 (0)421 63 93 3 0Italy ............................+39 039 2876027Netherlands...........+49 (0)421 63 93 3 0Norway ........................+47 63 94 60 18Sweden................. +46 (0)8 555 367 00Switzerland............ +41 (0)56 448 90 80United Kingdom ....+44 (0)118 984 5515

Asian Sales OfficesShanghai................... +86 21 51388389Singapore ..................... +65 6411 6902

Distributors

Australia ......................+61 2 9809 5022 AmtexSlovenia.......................+386 1 583 7930 ElbacompCzech Rep. ...............+420 235 366 129 Vums PowerpragCzech Rep. ...............+420 539 050 630 Koala ElektronikEstonia............................+372 6228866 ElgertaGreece......................+30 210 240 1961 ADEM ElectronicsHungary ........................+36 1 705 2345 JAMSoftIndia ...............+91 80 4095 9330/31/32 DigiprotechIsrael ............................+972 9 7498777 AppletecIsrael ......................+972 (0)73 7001212 CidevJapan..........................+81 48 864 7733 BellnixKorea ..........................+82 31 422 8882 HanpowerLatvia ............................+371 67501005 CaroLithuania ......................+370 5 2652683 ElgertaPoland .........................+48 22 8627500 GammaPortugal .....................+34 93 263 33 54 VencoRomania .....................+4 0348 730 920 Multichron T.L.Russia .......................+7 (495)234 0636 ProsoftRussia .......................+7 (812)325 5115 GammaSouth Africa ................+27 11 453 1910 VepacSpain .........................+34 93 263 33 54 VencoTaiwan .........................+886 3 3559642 Fullerton PowerTurkey .......................+90 212 465 7199 EMPA

Global Catalog DistributorsAmericas ....................................Newark newark.comEurope .........................................Farnell farnell.comAsia .......................................element14 element14.com

07-Nov-11

Page 13: ECS65 - ECS130 · xppower.com 2 InputCharacteristics Characteristic Minimum Typical Maximum Units Notes&Conditions InputVoltage-Operating 80 115/230 275 VAC Derateoutputpower

ECS100 Series

• IT & Medical Safety Approvals

• <0.5 W Standby Power

• High Power Density 10 W/in3

• 80/100 W Convection & Force�cooled Ratings

• Class I & Class II Installations

• Industry Standard 2.0” x 4.0” x 1.25” Format

• Class B Radiated Emissions (‘ �B’ Models)

• Low Earth Leakage Current

• 3 Year Warranty

The ECS100 Series has been designed to minimise the no load power consumption (<0.5 W) and maximise efficiency in order tofacilitate equipment design to the latest environmental legislation.

Approved for Class I and Class II applications, the ECS100 range of single output AC-DC, 100 W power supplies feature high powerdensity in an industry standard 2 x 4" (51.0 mm x 102.0 mm) footprint. The 1.20" (31.0 mm) high, 1U compatible high-density powersupplies meet EN55022 Level B emissions with low earth leakage currents of 100 µA at 115 VAC or 215 µA at 230 VAC. Makingthese switchers ideal for industrial, IT and medical applications.

The ECS100 series has single output versions from 12 V to 48 VDC, adjustable by ±10%. They are dual-fused for compliance withIEC60601-1 and efficiency is 88% typical, so minimal excess heat is generated. The ECS100 require only 10 CFM of cooling todelivers a full 100 W of power up to +50 °C and operates at up to +70 °C with derating or equallly supply 80 W when convection-cooled up to +50 ˚C with operation to +70 ˚C with derating.

Page 14: ECS65 - ECS130 · xppower.com 2 InputCharacteristics Characteristic Minimum Typical Maximum Units Notes&Conditions InputVoltage-Operating 80 115/230 275 VAC Derateoutputpower

xppower.com

2

Input CharacteristicsCharacteristic Minimum Typical Maximum Units Notes & Conditions

Input Voltage - Operating 80 115/230 264 VAC Derate output power < 90 VAC. See fig. 1

Input Frequency 47 50/60 400 Hz Agency approval 47-63 Hz

Power Factor >0.5230 VAC, 100% loadEN61000-3-2 class A compliant

Input Current - No Load 0.02/0.04 A 115/230 VAC

Input Current - Full Load 1.5/0.9 A 115/230 VAC

Inrush Current 40 A 230 VAC cold start, 25 º C

No Load Input Power 0.3/0.4 0.5 W 115/230 VAC

Earth Leakage Current100/215 260 µA 115/230 VAC/50 Hz (Typ.), 264 VAC/60 Hz (Max.)

0.5/1.1 mA 115/230 VAC/400 Hz

Input Protection T3.15A/250 V internal fuse in both line and neutral

Output CharacteristicsCharacteristic Minimum Typical Maximum Units Notes & Conditions

Output Voltage - V1 12 48 VDC See Models and Ratings table

Initial Set Accuracy ±1 % 50% load, 115/230 VAC

Output Voltage Adjustment ±10 % Via potentiometer. See mech. details (page 9)

Minimum Load 0 A

Start Up Delay 1 s 230 VAC full load (see fig.2)

Hold Up Time 16 ms 115 VAC full load (see fig.3)

Drift ±0.2 % After 20 min warm up

Line Regulation ±0.5 % 90-264 VAC

Load Regulation ±1 % 0-100% load.

Transient Response - V1 4 %Recovery within 1% in less than 500 µsfor a 50-75% and 75-50% load step

Over/Undershoot - V1 5 % See fig.4

Ripple & Noise 1 % pk-pk 20 MHz bandwidth (see fig.5 & 6)

Overvoltage Protection 115 140 % Vnom DC.

Overload Protection 110 150 % I nom Auto reset (see fig.7)

Short Circuit Protection Continuous, trip & restart (hiccup mode)

Temperature Coefficient 0.05 %/˚ C

Overtemperature Protection °C Not fitted

Models and Ratings - Convection-cooled

Notes:1. For Class B radiated emissions models, add suffix -B to model number. For covered versions, add suffix ‘-C’ to model number or order part no. ECM40/60 COVER

KIT for standalone cover. Derate output power by 20% with cover. The cover is not suitable for Class II installations.

Output PowerOutput Voltage V1 Max Output Current Model Number(1)

Forced Cooled (10 CFM) Convection Cooled100 W 80 W 12.0 VDC 8.3 A ECS100US12100 W 80 W 15.0 VDC 6.7 A ECS100US15100 W 80 W 18.0 VDC 5.5 A ECS100US18100 W 80 W 24.0 VDC 4.2 A ECS100US24100 W 80 W 28.0 VDC 3.6 A ECS100US28100 W 80 W 48.0 VDC 2.1 A ECS100US48

Page 15: ECS65 - ECS130 · xppower.com 2 InputCharacteristics Characteristic Minimum Typical Maximum Units Notes&Conditions InputVoltage-Operating 80 115/230 275 VAC Derateoutputpower

xppower.com

3

Start Up Delay From AC Turn OnFigure 2Start up example from AC turn on(230 VAC, 720 ms)

Hold Up Time From Loss of AC

Figure 3Hold up example at 100 W loadwith 115 VAC input (17.2ms)

Input Voltage Derating

Figure. 1

40

50

80

60

70

90

100

80 9085 264

Input Voltage (VAC)

Out

put

Pow

er(%

)

Page 16: ECS65 - ECS130 · xppower.com 2 InputCharacteristics Characteristic Minimum Typical Maximum Units Notes&Conditions InputVoltage-Operating 80 115/230 275 VAC Derateoutputpower

Output Ripple & Noise

Figure 5ECS100US12 (100 W)66 mV pk-pk ripple. 20 MHz BW

xppower.com

4

Typical Output Overshoot

Figure 4Typical Output Overshoot(ECS100US12, 230 VAC)

Page 17: ECS65 - ECS130 · xppower.com 2 InputCharacteristics Characteristic Minimum Typical Maximum Units Notes&Conditions InputVoltage-Operating 80 115/230 275 VAC Derateoutputpower

Output Ripple & Noise cont.

Figure 6ECS100US24 (100 W)58 mV pk-pk ripple. 20 MHz BW

xppower.com

5

Output Overload Characteristic

Figure 7Typical OverloadCharacteristic(ECS100US12 shown)

Output entersTrip & Restart Mode

0

2

4

6

8

10

12

14

0 1 2 3 6 7 8 9 10

Output Current (A)

Out

put

Volts

(V)

Page 18: ECS65 - ECS130 · xppower.com 2 InputCharacteristics Characteristic Minimum Typical Maximum Units Notes&Conditions InputVoltage-Operating 80 115/230 275 VAC Derateoutputpower

xppower.com

Xxxxxxxxxx

6

General Specifications

Characteristic Minimum Typical Maximum Units Notes & Conditions

Efficiency 88 % Full load (see fig.8 & 9)

Isolation: Input to OutputInput to GroundOutput to Ground

4000 VAC

1500 VAC

500 VDC

Switching Frequency 65 kHz

Power Density 10 W/in3

Mean Time Between Failure834

kHrsMIL-HDBK-217F, Notice 2 +25 °C GB

1245 Telecordia SR-332 +25 º C

Weight 0.4 (175) lb (g)

Efficiency Versus Load

81.00%

82.00%

83.00%

84.00%

85.00%

86.00%

87.00%

88.00%

89.00%

0 20 40 60 80 100

Effic

ienc

y

Output Load Wattage (W)

83.00%

84.00%

85.00%

86.00%

87.00%

88.00%

89.00%

90.00%

91.00%

0 20 40 60 80 100

Effic

ienc

y(%

)

Output Load Wattage (W)

y p

Figure 8ECS100US12 at 230 VAC

Figure 9ECS100US24 at 230 VAC

Page 19: ECS65 - ECS130 · xppower.com 2 InputCharacteristics Characteristic Minimum Typical Maximum Units Notes&Conditions InputVoltage-Operating 80 115/230 275 VAC Derateoutputpower

xppower.com

Xxxxxxxxxx

7

EnvironmentalCharacteristic Minimum Typical Maximum Units Notes & Conditions

Operating Temperature -20 +70 º CDerate linearly from +50 º C at 2.5%/º Cto 50% at 70 º C. (See fig.10 & ThermalConsiderations)

Storage Temperature -40 +85 º C

Cooling 10 CFM>80 W output power.See fig.10 & Thermal Considerations

Humidity 5 95 %RH Non-condensing

Operating Altitude 3000 m

Shock3 x 30 g/11 ms shocks in both +ve & -vedirections along the 3 orthogonal axis,total 18 shocks.

Vibration Three axis 5-500 Hz at 2 g x 10 sweeps

Electromagnetic Compatibility - Immunity

Phenomenon Standard Test Level Criteria Notes & Conditions

Low Voltage PSU EMC EN61204-3 High severity level as below

Harmonic Current EN61000-3-2 Class A

Radiated EN61000-4-3 3 A

EFT EN61000-4-4 3 A

Surges EN61000-4-5 Installation class 3 A

Conducted EN61000-4-6 3 A

Dips and Interruptions

EN61000-4-11

Dip: 30% 10 ms A

Dip: 60% 100 ms B

Dip: 100% 5000 ms B

EN60601-1-2

Dip: 30% 500 ms A

Dip: 60% 100 ms ALoad derating with 115 VAC input (typically50% derate dependant on model & load)

Dip: 100% 10 ms A

Int.: >95% 5000 ms B

Figure 10

Derating Curve

+70

40

50

80

60

70

90

100

-20 +50+40 +60

Ambient Temperature (ºC)

Out

put

Pow

er(W

)

30

Force-cooled >10 CFM

Convection-cooled

Convection-cooled with cover

Page 20: ECS65 - ECS130 · xppower.com 2 InputCharacteristics Characteristic Minimum Typical Maximum Units Notes&Conditions InputVoltage-Operating 80 115/230 275 VAC Derateoutputpower

xppower.com

8

Electromagnetic Compatibility - Emissions

Phenomenon Standard Test Level Criteria Notes & Conditions

Conducted EN55011/22 Class B See fig. 11

Radiated EN55011/22Class A

Class B ECS100-B Models

Voltage Fluctuations EN61000-3-3

Safety Agency Approvals

Figure 11Typical conductednoise plot (Class I)

Typical EMC Plot

Safety Agency Safety Standard Category

CB Report UL US/13728/UL IEC60950-1:2005 Ed 2 Information Technology

UL UL File #139109 UL60950-1 (2007), CSA 22.2 No.60950-1-07 Ed 2 Information Technology

TUV TUV Certificate # B 09 04 57396 059, EN60950-1:2006 Information Technology

CE LVD

Safety Agency Safety Standard Category

CB Report IEC60601-1 Ed 3 Including Risk Management Medical

UL UL File # E146893, ANSI/AAMI ES 60601-1:2005 & CSA C22.2 No. 60601-1:08 Medical

TUV EN60601-1:2006 Medical

Equipment Protection Class Safety Standard Notes & Conditions

Class I & Class II IEC60950-1:2005 Ed 2 & IEC60601-1 Ed 3See safety agency conditions ofacceptability for details

Means of Protection Category

Primary to Secondary 2 x MOPP (Means of Patient Protection)

IEC60601-1 Ed 3Primary to Earth 1 x MOPP (Means of Patient Protection)

Secondary to Earth 1 x MOPP (Means of Patient Protection)

Page 21: ECS65 - ECS130 · xppower.com 2 InputCharacteristics Characteristic Minimum Typical Maximum Units Notes&Conditions InputVoltage-Operating 80 115/230 275 VAC Derateoutputpower

Mechanical Details

Open Frame Versions

‘-B’ Model

xppower.com

9

Notes1. All dimensions in inches (mm).Tolerance .xx = ±0.02 (0.50); .xxx = ±0.01 (0.25)

2. Weight: 0.4 lbs (175 g) (Open Frame)

4.00 (101.6)

C5T1

C4

0.125 (3.18)

2.00(50.8)

1.00(25.4)

0.125 (3.18)

0.20 (5.1)

0.25 FastonGround Tab

4 X ø.156 (3.96) Mounting Holesø.312 (7.92) Clearance top and bottom

1.01(25.7)

VoltageAdj.

1.750(44.45)

J1

J2

3.750 (95.25)

Q1

0.20 (5.1)

1.25 (31.8)

0.14 (3.5)SMD Component

Height

4.50 (114.3)

3.75 (95.25)

J1

J2

0.37 (9.52)

1.75(44.45)

1.01(25.7)

0.125 (3.18)

0.20(5.1)

0.10 (2.5)0.25 Faston Ground Tab

4 X ø.156 (3.96) Mounting Holesø.312 (7.92) Clearance top and bottom

0.20 (5.1)

2.00(50.8)

1.25 (31.8)

0.14 (3.5)SMD Component

Height

1.00(25.4)

J1 mates with Molex HousingPN 09-50-1031,J2 mates with Molex HousingPN 09-50-1041 and bothwith Molex Series 5194 CrimpTerminals

Input Connector J1Molex PN 09-65-2038

Pin 1 Line

Pin 2 Neutral

0.25” Faston Earth

Output Connector J2Molex PN 09-65-2048Pin 1 +V1Pin 2 +V1Pin 3 RTNPin 4 RTN

Page 22: ECS65 - ECS130 · xppower.com 2 InputCharacteristics Characteristic Minimum Typical Maximum Units Notes&Conditions InputVoltage-Operating 80 115/230 275 VAC Derateoutputpower

Thermal Considerations

In order to ensure correct and reliable operation of the PSU in the most adverse conditions permitted in the end-use equipment, the temperature of thecomponents listed in the table below must not be exceeded. See drawing on page 13 for component locations. Temperature should be monitoredusing K type thermocouples placed on the hottest part of the component (out of any direct air flow).

Temperature Measurements (Ambient ≤ 50 º C)Component Max Temperature º C

T1 110 º C

C5 100 º C

C4 100 º C

Q1 110 º C

xppower.com

10

Covered Versions -C (not available for -B models)

Input Connector Output Connector

0.25 (0.6) GroundFaston Terminal

4.49 (114.0)

2.52(64.0)

1.54(39.0) 2 x M3 x 0.5 THD

0.16 (4.0)Max Screw Penetration

0.807(20.50)

4.055 (103.00)

0.22(5.5)

0.79(20.0)

4 x M3 x 0.5 THD0.16 (4.0) Max Screw Penetration

4.055 (103.00)

0.984(25.00)

0.22(5.5)

Notes1. All dimensions in inches (mm).Tolerance .xx = ±0.02 (0.50); .xxx = ±0.01 (0.25)

2. Weight: 0.4 lbs (175 g) (Open Frame)

J1 mates with Molex HousingPN 09-50-1031,J2 mates with Molex HousingPN 09-50-1041 and bothwith Molex Series 5194 CrimpTerminals

Input Connector J1Molex PN 09-65-2038

Pin 1 Line

Pin 2 Neutral

0.25” Faston Earth

Output Connector J2Molex PN 09-65-2048Pin 1 +V1Pin 2 +V1Pin 3 RTNPin 4 RTN

Page 23: ECS65 - ECS130 · xppower.com 2 InputCharacteristics Characteristic Minimum Typical Maximum Units Notes&Conditions InputVoltage-Operating 80 115/230 275 VAC Derateoutputpower

www.xppower.comwww.xppower.com

North American HQ

XP Power990 Benecia Avenue, Sunnyvale, CA 94085Phone : +1 (408) 732-7777Fax : +1 (408) 732-2002Email : [email protected]

European HQ

XP PowerHorseshoe Park, Pangbourne, Berkshire, RG8 7JWPhone : +44 (0)118 984 5515Fax : +44 (0)118 984 3423Email : [email protected]

German HQ

XP PowerAuf der Höhe 2, D-28357 Bremen, GermanyPhone : +49 (0)421 63 93 3 0Fax : +49 (0)421 63 93 3 10Email : [email protected]

Asian HQXP Power401 Commonwealth Drive, Haw Par Technocentre,Lobby B #02-02, Singapore 149598Phone : +65 6411 6900Fax : +65 6741 8730Email : [email protected] : www.xppowerchina.com /

www.xppower.com

North American Sales OfficesToll Free ....................+1 (800) 253-0490Central Region ..........+1 (972) 578-1530Eastern Region .......+1 (973) 658-8001Western Region ........+1 (408) 732-7777

European Sales OfficesAustria....................+43 (0)1 41 63 3 08Belgium.................+33 (0)1 45 12 31 15Denmark ......................+45 43 42 38 33Finland ...................+46 (0)8 555 367 01France ..................+33 (0)1 45 12 31 15Germany ...............+49 (0)421 63 93 3 0Italy ............................+39 039 2876027Netherlands...........+49 (0)421 63 93 3 0Norway ........................+47 63 94 60 18Sweden................. +46 (0)8 555 367 00Switzerland............ +41 (0)56 448 90 80United Kingdom ....+44 (0)118 984 5515

Asian Sales OfficesShanghai................... +86 21 51388389Singapore ..................... +65 6411 6902

Distributors

Australia ......................+61 2 9809 5022 AmtexSlovenia.......................+386 1 583 7930 ElbacompCzech Rep. ...............+420 235 366 129 Vums PowerpragCzech Rep. ...............+420 539 050 630 Koala ElektronikEstonia............................+372 6228866 ElgertaGreece......................+30 210 240 1961 ADEM ElectronicsHungary ........................+36 1 705 2345 JAMSoftIndia ...............+91 80 4095 9330/31/32 DigiprotechIsrael ............................+972 9 7498777 AppletecIsrael ......................+972 (0)73 7001212 CidevJapan..........................+81 48 864 7733 BellnixKorea ..........................+82 31 422 8882 HanpowerLatvia ............................+371 67501005 CaroLithuania ......................+370 5 2652683 ElgertaPoland .........................+48 22 8627500 GammaPortugal .....................+34 93 263 33 54 VencoRomania .....................+4 0348 730 920 Multichron T.L.Russia .......................+7 (495)234 0636 ProsoftRussia .......................+7 (812)325 5115 GammaSouth Africa ................+27 11 453 1910 VepacSpain .........................+34 93 263 33 54 VencoTaiwan .........................+886 3 3559642 Fullerton PowerTurkey .......................+90 212 465 7199 EMPA

Global Catalog DistributorsAmericas ....................................Newark newark.comEurope .........................................Farnell farnell.comAsia .......................................element14 element14.com

18-Jun-13

Page 24: ECS65 - ECS130 · xppower.com 2 InputCharacteristics Characteristic Minimum Typical Maximum Units Notes&Conditions InputVoltage-Operating 80 115/230 275 VAC Derateoutputpower

ECS130 Series

• IT & Medical Safety Approvals

• Industry Standard 2.0” x 4.0 x 1.25” Format

• < 0.5W Standby Power

• Convection & Forced Cooled Ratings

• �40° C to +70° C Operation

• Class I & Class II Installations

• Low Earth Leakage Current

• Class B Emissions

• 3 Year Warranty

The ECS130 Series has been designed to minimise the no load power consumption (<0.5 W) and maximise efficiency in order tofacilitate equipment design to the latest environmental legislation.

Approved for Class I and Class II applications, the ECS130 range of single output AC-DC, 130 W power supplies feature high powerdensity in an industry standard 2” x 4" (51.0 mm x 102.0 mm) footprint. The 1.25" (31.8 mm) high, 1U compatible high-density powersupplies meet EN55022 Level B emissions with low earth leakage currents of 100 μA at 115 VAC or 215 μA at 230 VAC. Makingthese switchers ideal for industrial, IT and medical applications.

The ECS130 series has single output versions from 12 V to 48 VDC, adjustable by ±10%. They are dual-fused for compliance withIEC60601-1 and efficiency is 88% typical, so minimal excess heat is generated. The ECS130 require only 10 CFM of cooling todelivers a full 130 W of power up to +50 °C and operates at up to +70 °C with derating or equally can supply 100 W whenconvection cooled up to +50 °C with operation to +70 °C with derating.

POWERGREEN

Page 25: ECS65 - ECS130 · xppower.com 2 InputCharacteristics Characteristic Minimum Typical Maximum Units Notes&Conditions InputVoltage-Operating 80 115/230 275 VAC Derateoutputpower

xppower.com

2

Input Characteristics

Characteristic Minimum Typical Maximum Units Notes & Conditions

Input Voltage - Operating 80 115/230 264 VAC See derating curve. See fig 1.

Input Frequency 47 50/60 63 Hz

Power Factor >0.5 230 VAC, 100% loadEN61000-3-2 Class A Compliant.

Input Current - No Load 0.03 A

Input Current - Full Load 1.9/1.1 A 115/230 VAC

Inrush Current 40 A 230 VAC cold start 25 °C

No Load Input Power 0.5 W

Earth Leakage Current 260 µA 264 VAC/60 Hz (Max.)

Input Protection F3.15 A/250 V internal fuse in both lines

Output Characteristics

Characteristic Minimum Typical Maximum Units Notes & Conditions

Output Voltage - V1 12 48 VDC See Models and Ratings table

Initial Set Accuracy ±1 % 50% load, 115/230 VAC

Output Voltage Adjustment -V1 ±10 % Via potentiometer. See mech. details,

Minimum Load 0 A

Start Up Delay 1 s 115/230 VAC full load

Hold Up Time 18 ms

Drift ±0.2 % After 20 min warm up

Line Regulation ±0.5 % 90-264 VAC

Load Regulation % 0-100% load

Transient Response - V1 4 % Recovery within 1% in less than 500 µsfor a 50-75% and 75-50% load step

Over/Undershoot - V1 5 %

Ripple & Noise - V1 1 % pk-pk 20 MHz bandwidth, 12V Models 1.5% max

Overvoltage Protection - V1 115 140 % Vnom DC. Output 1, recycle input to reset

Overload Protection - V1 110 160 % I nom See fig. 2. Trip and Restart

Short Circuit Protection - V1 Continuous

Temperature Coefficient 0.05 %/˚C

Overtemperature Protection °C Not fitted

Models and Ratings

1. For covered versions, add suffix ‘-C’ to model number or order part no. ECM40/60 COVER KIT for standalone cover, see derating curve.The cover is not suitable for Class II installations. ‘-C’.

Output PowerOutput Voltage Output Current Model Number(1)

Forced Cooled (10 CFM) Convection-cooled

130 W 100 W 12.0 VDC 10.9 A ECS130US12†^

130 W 100 W 15.0 VDC 8.7 A ECS130US15†^

130 W 100 W 18.0 VDC 7.3 A ECS130US18

130 W 100 W 24.0 VDC 5.4 A ECS130US24†^

130 W 100 W 28.0 VDC 4.7 A ECS130US28†^

130 W 100 W 48.0 VDC 2.7 A ECS130US48†^

Page 26: ECS65 - ECS130 · xppower.com 2 InputCharacteristics Characteristic Minimum Typical Maximum Units Notes&Conditions InputVoltage-Operating 80 115/230 275 VAC Derateoutputpower

xppower.com

3

Input Voltage Derating Curve

Output Overload Characteristic

Figure 1

2010

3040

50

60

7080

90100

110120

130

80 10090 264Input Voltage (VAC)

Outp

utPo

wer(

W)

Forced-cooled >10 CFM

Convection-cooled

Convection-cooled with cover

Output entersTrip & Restart Mode

0

2

4

6

8

10

12

14

0 1 2 3 6 7 8 9 10

Output Current (A)

Outp

utVo

lts(V

)Figure 212V Models

Page 27: ECS65 - ECS130 · xppower.com 2 InputCharacteristics Characteristic Minimum Typical Maximum Units Notes&Conditions InputVoltage-Operating 80 115/230 275 VAC Derateoutputpower

xppower.com

4

Efficiency Versus Load

General Specifications

Characteristic Minimum Typical Maximum Units Notes & Conditions

Efficiency 88 % 230 VAC Full load (see fig.3-5)

Isolation: Input to OutputInput to GroundOutput to Ground

4000 VAC

1500 VAC

500 VDC

Switching Frequency 65 kHz

Power Density 13 W/in3

Mean Time Between Failure 715 kHrs MIL-HDBK-217F, Notice 2+25 °C GB

Weight: Open FrameCovered Unit

0.40 (0.18) lb (kg)

0.80 (0.36) lb (kg)

Figure 5 - 48V Models

Figure 3 - 12V Models

Figure 4 - 24V Models

20% 25% 50% 75% 100%

115 V

230 V

0.00%

10.00%

20.00%

30.00%

40.00%

50.00%

60.00%

70.00%

80.00%

90.00%

100.00%

Load %

Effici

ency

(%)

0.00%

10.00%

20.00%

30.00%

40.00%

50.00%

60.00%

70.00%

80.00%

90.00%

100.00%

20% 25% 50% 75% 100%

115 V

230 V

Load %

Effici

ency

(%)

20% 25% 50% 75% 100%

115 V

230 V

0.00%

10.00%

20.00%

30.00%

40.00%

50.00%

60.00%

70.00%

80.00%

90.00%

100.00%

Load %

Effici

ency

(%)

Page 28: ECS65 - ECS130 · xppower.com 2 InputCharacteristics Characteristic Minimum Typical Maximum Units Notes&Conditions InputVoltage-Operating 80 115/230 275 VAC Derateoutputpower

xppower.com

5

Environmental

Thermal Derating Curve

Characteristic Minimum Typical Maximum Units Notes & ConditionsOperating Temperature -40 +70 °C See derating curve, fig. 6Storage Temperature -40 +85 °CCooling 10 CFM Forced Cooled >100 WHumidity 5 95 %RH Non-condensingOperating Altitude 3048 m

Shock±3 x 30g shocks in each plane, total 18shocks. 30g = 11ms (+/-0.5msec), half sine.Conforms to EN60068-2-27 & EN60068-2-47

VibrationSingle axis 10 - 500 Hz at 2g sweep andendurance at resonance in all 3 planes.Conforms to EN60068-2-6

Figure 6

Ambient Temperature (ºC)

Outp

utPo

wer(

W)

2010

3040

50

60

7080

90100

110120

130

-40 0-20 6050 70

Forced-cooled >10 CFM

Convection-cooled

Convection-cooled with cover

Som

esp

ecific

atio

npa

ram

ete

rsm

ayno

tbe

met

Page 29: ECS65 - ECS130 · xppower.com 2 InputCharacteristics Characteristic Minimum Typical Maximum Units Notes&Conditions InputVoltage-Operating 80 115/230 275 VAC Derateoutputpower

xppower.com

6

Electromagnetic Compatibility - ImmunityPhenomenon Standard Test Level Criteria Notes & Conditions

Low Voltage PSU EMC EN61204-3 High severity level as below

Harmonic Current EN61000-3-2 Class A

Radiated EN61000-4-3 3 A

EFT EN61000-4-4 3 A

Surges EN61000-4-5 Installation class 3 A

Conducted EN61000-4-6 3 A

Dips and Interruptions

EN55024(100 VAC)

Dip >95% (0 VAC), 8.3ms B

Dip 30% (70 VAC), 416ms B

Dip >95% (0 VAC), 4160ms B

EN55024(240 VAC)

Dip >95% (0 VAC), 10.0ms B

Dip 30% (168 VAC), 500ms B

Dip >95% (0 VAC), 5000ms B

EN60601-1-2(100 VAC)

Dip >95% (0 VAC), 10.0ms A Derate Output Power to 100 W

Dip 60% (40 VAC), 100ms A Derate Output Power to 12 W

Dip 30% (70 VAC), 500ms A Derate Output Power to 100 W

Dip >95% (0 VAC), 5000ms B

EN60601-1-2(240 VAC)

Dip >95% (0 VAC), 10.0ms A

Dip 60% (96 VAC), 100ms A

Dip 30% (168 VAC), 500ms A

Dip >95% (0 VAC), 5000ms B

Electromagnetic Compatibility - EmissionsPhenomenon Standard Test Level Criteria Notes & Conditions

Conducted EN55011/22 Class B

Radiated EN55011/22 Class A

Voltage Fluctuations EN61000-3-3

Safety Agency Approvals

Safety Agency Safety Standard Category

CB Report IEC60950-1:2005 Ed 2 Information Technology

UL UL60950-1 (2007), CSA 22.2 No.60950-1-07 Ed 2 Information Technology

TUV EN60950-1:2006 Information Technology

CE LVD

Safety Agency Safety Standard Category

CB Report IEC60601-1 Ed 3 Including Risk Management Medical

UL ANSI/AAMI ES60601-1:2005 & CSA C22.2, No.60601-1:08 Medical

TUV EN60601-1/A12:2006 Medical

Equipment Protection Class Safety Standard Notes & Conditions

Class I & Class II IEC60950-1:2005 Ed 2 & IEC60601-1 Ed 2 See safety agency conditions of acceptibilityfor details

Means of Protection Category

Primary to Secondary 2 x MOPP (Means of Patient Protection)

IEC60601-1 Ed 3Primary to Earth 1 x MOPP (Means of Patient Protection)

Secondary to Earth 1 x MOPP (Means of Patient Protection)

Page 30: ECS65 - ECS130 · xppower.com 2 InputCharacteristics Characteristic Minimum Typical Maximum Units Notes&Conditions InputVoltage-Operating 80 115/230 275 VAC Derateoutputpower

xppower.com

Xxxxxxxxxx

7

Mechanical Details - ECC100USxx

Notes1. All dimensions in inches (mm).

Tolerance .xx = ±0.02 (0.50); .xxx = ±0.01 (0.25)2. Weight: 0.386 lbs (175 g)

Mechanical Details

SMD COMPONENT HEIGHT

4X �.156 (3.96) MOUNTING HOLES�.312 (7.92) CLEARANCE TOP AND BOTTOM

J2T1

Q1

C4

C5

3.750 (95.25)

4.00 (101.6)

0.14 (3.5)

0.125 (3.17)

0.20 (5.1)

0.20 (5.1)

.25 FASTONGROUND TAB

J11.75 (44.45)

0.12 (3.18)

2.00 (50.8)

1.00 (25.4) 1.05 (26.7)

Voltage Adjust

1.25(31.8)

1

4

1

2N

L

J1 mates with Molex Housing PN 09-50-1031, J2 mates with Molex Housing PN 09-50-1041and both with Molex Series 5194 Crimp Terminals

Input Connector J1Molex PN 09-65-2038Pin 1 LinePin 2 Neutral

0.25” Faston Earth

Output Connector J2Molex PN 09-65-2048Pin 1 +V1Pin 2 +V1Pin 3 RTNPin 4 RTN

Page 31: ECS65 - ECS130 · xppower.com 2 InputCharacteristics Characteristic Minimum Typical Maximum Units Notes&Conditions InputVoltage-Operating 80 115/230 275 VAC Derateoutputpower

xppower.com

8

Notes1. All dimensions in inches (mm).

Tolerance .xx = ±0.02 (0.50); .xxx = ±0.01 (0.25)2. Weight: 0.8 lbs (360 g)

Mechanical Details - Covered (-C)

Input Connector Output Connector

0.25 (0.6) GroundFaston Terminal

4.49 (114.0)

2.52(64.0)

1.54(39.0) 2 x M3 x 0.5 THD

0.16 (4.0)Max Screw Penetration

0.807(20.50)

4.055 (103.00)

0.22(5.5)

0.79(20.0)

4 x M3 x 0.5 THD0.16 (4.0) Max Screw Penetration

4.055 (103.00)

0.984(25.00)

0.22(5.5)

Page 32: ECS65 - ECS130 · xppower.com 2 InputCharacteristics Characteristic Minimum Typical Maximum Units Notes&Conditions InputVoltage-Operating 80 115/230 275 VAC Derateoutputpower

xppower.com

Xxxxxxxxxx

9

Thermal Considerations

In order to ensure safe operation of the PSU in the end-use equipment, the temperature of the components listed in the table below must not beexceeded. Temperature should be monitored using K type thermocouples placed on the hottest part of the component (out of any direct air flow). SeeMechanical Details for component locations.

Temperature Measurements (Ambient 50 °C )

Component Max Temperature °C

T1 Coil 120 °C

Q1 Body 120 °C

C5 105 °C

C4 105 °C

Service Life

The estimated service life of the ECS130 Series is determined by the cooling arrangements and load conditions experienced in the end application.Due to the uncertain nature of the end application this estimated service life is based on the actual measured temperature of a key capacitor within theproduct when installed in the end application.

The graph below expresses the estimated lifetime for a given component temperature and assumes continuous operation at this temperature.

5000

25000

45000

65000

85000

105000

125000

145000

165000

185000

105 95 85 75 65

C5 Temperature (°C)

Lifet

ime

(Hrs

)

55

Estimated Service Life vs Component Temperature

Page 33: ECS65 - ECS130 · xppower.com 2 InputCharacteristics Characteristic Minimum Typical Maximum Units Notes&Conditions InputVoltage-Operating 80 115/230 275 VAC Derateoutputpower

www.xppower.com

North American HQ

XP Power990 Benecia Avenue, Sunnyvale, CA 94085Phone : +1 (408) 732-7777Fax : +1 (408) 732-2002Email : [email protected]

European HQ

XP PowerHorseshoe Park, Pangbourne, Berkshire, RG8 7JW, UKPhone : +44 (0)118 984 5515Fax : +44 (0)118 984 3423Email : [email protected]

German HQ

XP PowerAuf der Höhe 2, D-28357 Bremen, GermanyPhone : +49 (0)421 63 93 3 0Fax : +49 (0)421 63 93 3 10Email : [email protected]

Asian HQXP Power401 Commonwealth Drive, Haw Par Technocentre,Lobby B #02-02, Singapore 149598Phone : +65 6411 6900Fax : +65 6741 8730Email : [email protected] : www.xppowerchina.com /

www.xppower.com

North American Sales OfficesToll Free ....................+1 (800) 253-0490New England.............+1 (603) 818-4020Mid Atlantic ...............+1 (973) 658-8001Central Region ..........+1 (972) 578-1530Western Region ........+1 (408) 732-7777

European Sales OfficesAustria.....................+43 (0)1 41 63 3 08Belgium.................+33 (0)1 45 12 31 15Denmark ......................+45 43 42 38 33Finland ....................... +358 2 4788 500France ..................+33 (0)1 45 12 31 15Germany ...............+49 (0)421 63 93 3 0Italy ............................+39 02 70103517Netherlands...........+49 (0)421 63 93 3 0Norway ........................+47 63 94 60 18Sweden................. +46 (0)8 555 367 00Switzerland............ +41 (0)56 448 90 80United Kingdom ....+44 (0)118 984 5515

Asian Sales OfficesShanghai................... +86 21 51388389Singapore ..................... +65 6411 6902

Distributors

Australia ......................+61 2 9809 5022 AmtexCzech Rep. ...............+420 235 366 129 Vums PowerpragCzech Rep. ...............+420 539 050 630 Koala ElektronikEstonia............................+372 6228866 ElgertaGreece......................+30 210 240 1961 ADEM ElectronicsHungary ........................+36 1 705 2345 JAMSoftIndia ...............+91 80 4095 9330/31/32 DigiprotechIsrael ............................+972 9 7498777 AppletecJapan..........................+81 48 864 7733 BellnixKorea ..........................+82 31 345 8982 HanpowerLatvia ............................+371 67501005 CaroLithuania ......................+370 5 2652683 ElgertaPoland .........................+48 22 8627500 GammaPortugal .....................+34 93 263 33 54 VencoRomania .....................+4 0348 730 920 Multichron T.L.Russia .......................+7 (495)234 0636 ProsoftRussia .......................+7 (812)325 5115 GammaSlovenia & Balkans......+386 1 583 7930 ElbacompSouth Africa ................+27 11 609 7122 VepacSpain .........................+34 93 263 33 54 VencoTaiwan .........................+886 3 3559642 Fullerton PowerTurkey .......................+90 212 465 7199 EMPA

Global DistributorsAmericas ..................Newark element14 newark.comEurope .......................Farnell element14 farnell.comAsia .......................................element14 sg.element14.com

06-Aug-13

www.xppower.com