19
ECOPRO ANMO Intelligent Anti-Epidemic Monitoring Workstation Operating Instruction Manual 1

ECOPRO ANMO Intelligent Anti-Epidemic Monitoring

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

ECOPRO ANMO

Intelligent Anti-Epidemic

Monitoring Workstation

Operating Instruction Manual

1

Operating Instruction Manual

ECOPRO ANMO Intelligent

Anti-Epidemic Monitoring Workstation

Operating Instruction Manual

Thank you for purchasing our products, please read this manual carefully

before the operation.

1

Operating Instruction Manual

2

ECOPRO ANMO Intelligent Anti-Epidemic Monitoring Workstation

Operating Instruction Manual

I. Introduction

ECOPRO ANMO Intelligent Anti-Epidemic Monitoring Workstation is suitable for public

health epidemic monitoring, automatic body temperature detection, mask wearing

detection, and spray disinfection. This workstation will reduce the labor intensity of

personnel, improve the safety for the personnel under high-frequency contacts, and

effectively avoid the risk of cross infection in public areas and crowded places.

ANMO is equipped with accessories such as casters and ramps, which is suitable for

various application scenarios. It has strong mobility and simple deployment, can work

sustainably when plugged in.

ANMO provides one-stop solutions including body temperature measurement,

disinfection, status recognition, commuting punch-in and data upload.

II. Scope of application

ECOPRO ANMO Intelligent Anti-Epidemic Monitoring Workstation can be used for

government agencies, hospitals, schools, supermarkets, communities, office buildings,

railway stations, airports, factories and other public areas and crowded places.

Operating Instruction Manual

III. Product Dimension

IV. Product Features

1400Product Dimension Diagram

Product Main Functions Diagram

Disinfection AreaDetection Area

Operating Instruction Manual

can collect body temperatures in real time, extract and compare peak value, and output

signal lamps and voice prompt. The temperature measurement module can adjust the

angle to adapt to different people.

When the body temperature is normal, the voice broadcasts the body temperature

value.

When the body temperature exceeds 37.3 ℃, it will give a double prompt of sound and

image, and automatically take photos and upload them to the administrator's computer

or mobile phone.

2. Automatic Mask Wearing Detection

ANMO can detect those who do not wear a mask, and voice reminds "Please wear a

mask".

3. Auto-induction Spray Hand Disinfection

ANMO adopts non-contact induction spraying, and can carry out hand disinfection

simultaneously when measuring temperature, with high efficiency, safety and health.

4. Commuting punch-in and wireless data transmission

ANMO can also achieve commuting punch-in and data unloading at the same time.

The face recognition system can support offline storage of 100,000 face photos and

recognition records. It can also monitor abnormal people and upload them to the server.

1. Automatic temperature monitoring

ANMO adopts imported high-precision industrial infrared spectrum sensor, which is

calibrated by blackbody radiation source before delivery. It can realize non-contact, fast

and reliable body temperature measurement, and effectively avoid cross infection. It

Operating Instruction Manual

5

Alarm light for

abnormaltemperature and

without mask Light for normal

temperature

Infraredtemperature

camera Face recognition

camera

Display screen

Flash light

Person punch

5. Auto-induction 3D spray disinfection

ANMO is equipped with microwave moving object induction sensor. When the

personnel enters, the automization machine is quickly started to perform

spray disinfection in the disinfection area.

6. Wind curtain closed disinfection area

Half of the space of ANMO is disinfection area. The floor of this area is completely

covered with disinfection carpet. The atomizing disinfection machine sprays disinfection

gas into this area and a wind curtain system is set to keep the area full of disinfection

gas at all times, for disinfecting the human body in all directions.

7. Non-contact during the whole process

During the whole process: temperature measurement → punch-in → mask recognition

→ hand disinfection → whole body disinfection, there is zero contact with the equipment,

effectively preventing cross infection.

Operating Instruction Manual

6

ANMO has two sets of universal casters with brakes and two sets of directional casters

with brakes, which are convenient for moving, fast layout, and can reduce storage

space occupation. Also nylon wheels to adapt to various road conditions.

9. Foldable auxiliary channel

The entrance and exit of ANMO are equipped with auxiliary access ramps, which are

convenient for people and wheelchairs to enter. The ramps are foldable and convenient

for movement and storage.

10. Simple deployment

The equipment uses 220V AC power, and the power consumption is less than 500W.

The layout is simple, no special personnel is required to install and debug the

equipment. The operation is simple, easy to learn and operate.

11. Electricity safety

ANMO is equipped with leakage protection system and anti-lightning surge system to

ensure the safety of users.

12. Passage lighting

The passage in ANMO is equipped with auto-sensing LED lighting, which is convenient

for use at night or in dark light environment.

8. Strong mobility

Operating Instruction Manual

7

➢ Monitoring platformMonitoring platform is an integrated

management platform for the deployment of

body temperature monitoring in the premisesof

daily monitoring, system management and

emergency command. It is a network platform

of Internet architecture, which has many

functions such as alarm processing, recording,

query, statistics and detection data curve

output of personnel traffic and data at

monitoring points in various regions.

➢ Transmission NetworkThe human temperature data and high-risk

data collected by the terminal device are sent

to the server over a 4G network.

Data acquisition system

It is mainly responsible for on-site image

acquisition, body temperature data acquisition

and network transmission. It is an integrated

machine of face recognition and body

temperature detection, which is used to monitor

body temperature data and collect face

recognition data. Alarm is provided for testdatawith a body temperature exceeding 37.3℃.

4G Wireless Transmission Network

Face recognition and body temperature detection integrated machine

Terminal Device

Monitoring PCServerCommand Screen

Monitoring Data Analysis Center

Public Publishing PlatformGovernment Monitoring Platform

V. Performance Parameters

1、Monitoring Module

1)Temperature alarm module

① Scheme system topology

② Face recognition and body temperature detection integrated machine –

Product Functions

⚫ Support the face recognition of people wearing masks

while completing temperature detection;

⚫ Built-in low-power temperature detection module,

second-level completion of detection, detection

distance in 0.5m;

⚫ Support verification of 1:N. Live detection in 1:N mode

to prevent photo and video attacks;

⚫ The dynamic face detection and tracking recognition

algorithm based on video flow

⚫ Support offline storage of 100,000 face photos and

recognition records;

⚫ Support preservation of face recognition on-site

photos;

⚫ Customizable development for functions of visitor

self-service appointment in WeChat official account and users face registration;

⚫ Support interface docking, support customization;⚫ Wireless remote data transmission, real-time display of data, information transparency a

accessible.⚫ Flexible storage of data, analysis of historical curve at any time, monitoring and management of

big data is accessible.

Operating Instruction Manual

8

③ Face recognition and body temperature detection integrated machine

- Parameters and Specifications

Parameters and Specifications

Hardware

Display Screen 7-inch LCD, resolution:1024 x 600@60HZ

Appearance material Aluminium housing, organic glass panel

Performance

Camera recognition height 1.2-2.2 m

Camera recognition distance 0.5-3m

Body temperature detection

distance

0.3-0.5m

Recognition technologySupport face recognition for swearing mask and infrared

array thermal imaging temperature detection

Face angles 30 degrees left and right, 30 degrees up and down

Near-infrared live detection, embedded visible face

Recognition technology recognition, adapted to most indoor and outdoor

environment, can be quickly identified in mobile

Detection tracking in 15ms, comparison per thousand

people in 80ms , feature extraction in 300ms

Name announcement display, customized information

broadcast display

Recognition time

Status display

Face Library 10,000 (expandable)

Master board interface

Power interfaceOne external socket and one built-in 6P socket (With STB)

DC 12V input

Network interface One RJ45 10M / 100M Adaptive Ethernet Port

Extending the interface One way of UART, One way of RS485

One way of WIFI, support 2.4G/5G WiFi and Wi-Fi

802.11b/g/n protocol

Expandable for one way of 3G (WCDMA, EVDO, CDMA),WIFI

3G/4G (Optional) GSM) or

(LTE-TDD/LTE-FDD/TD-SCDMA/EDGE/GPRS/GSM)

4G

SD Card Interface Scale up to 64GBTF card

Five ports, USB HOST (two external ports and three

built-in ports, one of the external ports is OTG)USB 2.0 interface

Camera parameters

CameraTwo megapixels, flat angle wide dynamic camera,

automatic white balance, automatic backlight optimization

1920*1080

1/3 inch image sensor, 4mm/6mm focal length, F2.4

aperture

Effective pixels

Lens

Operating Instruction Manual

9

Minimum illumination Colors 0.05Lux @F1.2 (ICR)

Signal-to-noise ratio ≥39db(AGC OFF)

Human temperature

measurement parameters

Use of German imported infrared thermal imaging

module

Thermal resolution

Thermal Imaging

Perspective(FOV)

Temperature measurement

range

Temperature measurement

distance

Temperature measurement

accuracy

32 x 32 Array

30°* 30°

30℃-45℃

0.5m

±0.3℃

Card reading module

(Optional)

Card type identification Read M1IC Card Series Number and ID Series Number

RF operation frequency 13.56MHZ

Operation effective distance <3cm

Reading rate 15 times per second

ID module (Optional)

Standard specification

Conforms to ISO/IEC 14443 Type standard B, as well as

“GA450-2013 Desktop Resident ID Reader General

Technical Requirements”, “GA467 Resident ID Verification

Security Control Module Interface Technical

Specifications” and “GA/T1011-2012 Resident ID

Fingerprint Collector General Technical Requirements”

<1s

Card reading time

Reading distance 0-30mm

Data interface USB

Power specifications USB-powered

Operation frequency 13.56MHZ±7KHZ(fc)

General parameters

Operation temperature -10℃ - +50℃

Operation humidity 10~90% relative humidity

Power supply DC12V/3A

Device power consumption ≦25W

Size of device 218 x 116 x 22mm (Length*Width*Height)

Weight of device 0.3 kg (varies by configuration)

Operating Instruction Manual

10

Name Temperature Measurement Time

Abnormal data list

The first body temperature is detected to be high, the second

temperature detection is still high, so this person is transferred

to the hospital for further diagnosis.

Further Diagnosis

④ Examples of platform presentationAlarm display of abnormal person temperature data and time:

Processing and record of abnormal data:

View of Total Personnel Flow Statistics, Historical Data Curves, Abnormal

Personnel Statistics

2、Hand Disinfection Module

Power: Four No. 5 batteries

Power: ≤20W

Operating Instruction Manual

11

Fluid Spray Volume: 1ml±10%

3. Spray Disinfection Module

Voltage: 220V

Power: 200W

Volume: 24L

Atomization capacity: 3kg / h

Continuous use time for one filling: 8h

4. Air curtain module

Voltage: 220V

Power: 110W

Wind speed: 7m / S

Noise: 57db (a)

5. Lighting module

Voltage: 220V

Power: 9W

Color temperature: 5700k

Luminous flux: 650lm

Light source: LED

Quantity: 2Power

Operating Instruction Manual

12

Switch of

Nebulizer

Automatic

nebulizingLightMonitoring

moduleMain

Switch

VI. Commissioning Instruction

Commissioning Procedure:

1. Push up main switch;

2. Connect 220V power;

3. Turn on the relevant switches center closet. Functions of switches are shown in the

following figure.

Turn on the relevant switch according to usage requirement.

① Pull down the switch of nebulizer while not using it;

② Push up the switch of automatic nebulizer to start automatic nebulizing.

(Continuous nebulizing while pulled down);

4. Push up the monitoring module switch and wait for the monitoring module tostart;

5. Push up the switch of nebulizer. After the nebulizer has operated for 3 minutes, the

procedures of temperature detection, disinfection and work attendance check can be

started.

6. The nebulizer can be adjusted to work continuously, or work when the device detects

a living body (automatic nebulizing), see point 2.

Operating Instruction Manual

13

Disinfection AreaTemperature detection area

VII. Usage Instruction

1. Equipment Using Process:

User enters the intelligent anti-epidemic monitoring workstation and reach the

temperature detection area ①, and stands at this position for frontal temperature

measurement and face recognition punch-in. Meanwhile, the workstation will monitor if

the user has worn a mask and then disinfect his hands. Then user can enter the

disinfection area ②, and wait for a body disinfection for at least 2 seconds in the

disinfection area, and then leave the workstation and enter the relevant areas to study

or work.

2. Usage Instruction of Monitoring Module

After startup, the monitoring module automatically enters the face recognition &

temperature detection mode. User shall stand still at about 0.5m in front of the

recognition module. The detection module will detect body temperature and recognize

mask wearing, and give corresponding voice and text prompt.

① Pass: Normal body temperature and wearing a mask

Operating Instruction Manual

14

② Please wear a mask: User is not wearing a mask;

③ Abnormal body temperature: User’s body temperature has exceeded normal

standard.

Backstage management instruction:

① After purchasing this product, customer account and password will be provided to

log in the big data service platform;

② Use the offered account and password to log in the platform, the web site is

http://139.159.244.16:7070/index.koala?theme=default#

After logging in, click the vehicle monitoring→access record, as shown below:

③Introduce the equipment code and the simultaneous travelling time to check and

derive the information as shown below:

3. Hands disinfection module instruction

Put both your hands under the hand sterilizer to sense the liquid. After filling the

disinfectant, the hand sterilizer needs to repeat the induction action several times so as

to exhaust the air in the pump, and then it can be used normally.

4. Spray disinfection module instruction:

Operating Instruction Manual

15

① When you use the atomizer, it should be placed below the disinfectant surface;

② When you use the atomizer, the disinfectant surface should be 1-1.5cm higher than

the red water-break protection switch of the atomizer;

③ When the atomizer is taken out of the disinfectant, it should be cut off the electricity

before being used, or the red water-break protection switch makes it above the surface,

avoiding the atomizer plate burn dry;

④ When the disinfectant in water tank is little, we need to change the disinfectant in

time or let the liquid flow, avoiding the high temperature causing the atomizer over

heated protection.

VIII. Maintenance of Equipment

1. This product just need the general maintenance, surface cleaning and periodical

inspection, the time period is month. At the same time when you use the equipment,

you need a long-term and comprehensive consideration.

2. Clean the tank body regularly. If the dust is heavy in the surrounding space, the

period of cleaning space should be as short as possible; during the cleaning, avoiding

touching the electrical equipment such as the electric wire.

3. Should do the cleaning and disinfection for the floor and hand washer traytermly.

4. Check regularly whether the hand washer has the electricity, replace the battery in

time.

5. Check regularly whether the air outlet of the atomizing sterilizer is fluent, clean the

sludge in time.

Operating Instruction Manual

16

IX. Filling instruction

1. Filling the hand disinfectant

① As shown above, open the hand disinfection machine with the random matching key,

rive the hand disinfection machine storage lid, and do the filling.

② Using the VBK degerming water is suggested.

2. Filling the atomizer

Filling Point

① As shown above, open the atomizer’s lid with the random matching key, do the filling

directly;

② Pay attention to see if the floating borad float, don’t be stuck in it;

③ When the liquid surface is too low it will give the audible alarm, which means that the

disinfectant will run out soon;

① Add 24L disinfectant once can keep it working for 8 hours;

② Not suggest to use the 84 disinfectant (highly corrosive)and alcohol

disinfectant(Atomization is flammable and explosive).

Operating Instruction Manual

17

X. ECOPRO ANMO Intelligent Anti-Epidemic Monitoring Workstation

warranty card

1. Warranty policy

(1) ECOPRO ANMO Intelligent Anti-Epidemic Monitoring Workstation series products

has one-year product warranty period, each part’s warranty period is one year. During

this period, depending on this instruction, the users can dial the 24 hours service hotline

to connect with the ECOPRO Maintenance Workstation to deal with the On-site

installation commissioning/ after-sales maintenance business

(2) The warranty period is calculated from the date the users install and debug the

equipment.

(3) If the product exists any problem not in accordance of the contract caused by the

missing or misloading during the production process, the users can dial the 24 hours

service hotline within 7 days after the install to put forward the returning or replacing

goods application to the ECOPRO company, our company will deal with it according to

the relevant regulation.

2. Non-warranty clause

(1) If exceed the warranty period, not offering warranty;

(2) If the users alter or refit any spare part or wiring harness without permission, the

malfunction caused by altering the fuse model and specification, the malfunction

caused by the users’ own reason, they are not under the warranty of ourcompany;

(3) The damage or later relevant malfunction caused by Force Majeure(such as the

flood, earthquake, fire disaster, hail disaster, storm, air dust, chemical corrosion caused

by acid rain, etc), they are not under the warranty of our company.

3. 24 hours service hotline (install and debug/after-sales repair please dial

this hotline number. 400-855-0715

17

FOR MORE INFORMATION CONTACT