Economical utilization of coal bed methane emitted

during exploitation of coal seams

– energetic and environmental aspects

President of The Board

mgr inż. Roman Łój

Katowicki Holding Węglowy S.A.

The share of KHW S.A. in hard coal extraction in Poland in 2012 year

Katowicki Holding Węglowy S.A. – significant coal producer in Poland (UE)

Extraction of steam hard coal in Poland in 2012 year.

( % of share)

17,48%

11,72%

6,02%

6,28%2,75%

55,75%

Kompania Węglowa

Katowicki Holding Węglowy

LW Bogdanka

Południowy Koncern Węglowy

Jastrzębska Spółka Węglowa

Pozostałe

Extraction of hard coal in Poland in 2012 year.

( % of share)

50,27%

17,23%

14,85%

9,96%

5,12%

2,57%

Kompania Węglowa

Jastrzębska Spółka Węglowa

Katowicki Holding Węglowy

LW Bogdanka

Południowy Koncern Węglowy

Pozostałe

KWK „Murcki-Staszic”

KWK „Wieczorek”,

KWK „Mysłowice-Wesoła”

KWK „Wujek”

KWK „Kazimierz-Juliusz” Sp. z o.o.

Structure of Katowice Capital Group

Katowicki Holding Węglowy SA

KGK

Zakłady Energetyki Cieplnej

Katowicki Węgiel

Spółka Mieszkaniowa

Spółka Szkoleniowa

Common Services Center

MIN

ES

KHW S.A. – chosen economical and technical data

(2012 year)

Coal production: 11,6 mil. tons Coal export: 630 mil. tons Value of investments: 680 mil. PLN Sales income: 3 807,6 mil. PLN Employment: ~ 17,5 ths. persons Coal bed methane sales income: ~ 2,690 mil. PLN

5

KHW S.A. – chosen economical and technical data

(2012 year and 10 months of 2013 year)

2012 10 months 2013

Energetic use of methane

in installations of ZEC S.A. 10,24 mil. m3 15,4 mil. m3

Thermal energy production

from methane (ZEC S.A.): 183 ths. GJ 313 ths. GJ

Electrical energy production

from methane (ZEC S.A.): 21 GWh 39 GWh

Economical effect of using electrical energy

produced from methane in KHW S.A.: 690 ths. PLN 895 ths. PLN

Reduction of emmission of CO2 equivalent ~ 182 ths. tons ~ 260 ths. tons

Chosen coal bed methane data in mines of KHW S.A. (2012 year)

Quantity of methane emitted during exploitation of coal seams: 131,28 mil. m3

including:

- emitted to the atmosphere (by ventilation): 108,89 mil. m3

- captured in surface drainage stations: 22,39 mil. m3

- energetically used in installation of Thermal Energy Plants: 10,24 mil.m3

Reduction of emission to the atmosphere (equivalent of CO2) ~ 182 ths. tons

The example of effective methane drainage of coal seam

ŚCIANA 514 pokł. 501 partia

Az

Długość ściany

[m]

Wysokość ściany

[m]

Śr. wydobycie

[t/d]

225 do 3,8 m 3000

KWK „Mysłowice – Wesoła”:

Methane drainage station

Capture of methane - 41,30 m3/min

Utilization of methane by energy production

plants (ZEC) - 80%

Present absolute metanovelty of wall 514 in seam

501 part Az - 35,51 m3/min

Ventilation metanovelty - 10,80 m3/min

Methane drainage - 24,71 m3/min

Methane drainage efficiency for wall 514

region vary 50 – 70%.

It is the best result in KHW S.A. and one of the

best in polish deep hard coal mines.

Management of coal bed methane captured in drainage

stations

Captured in drainage stations mine methane gas is and will be used by dependent

company Zakłady Energetyki Cieplnej S.A. (Thermal Energy Plants) for production

of electrical energy and heat (also for production of cold in future) with the

environmental effect of reduction of greenhouse gases emmision to the atmosphere

Existing installations using coal bed methane

ZEC S.A. division No. V – „Wieczorek”

Number of engines

2 pcs

Rated power

2 x 1,485 MWe

1,615 MWt

Number of boilers

1 pc.

Boiler type and power

LOOS- 6MWt

ZEC S.A. division No. IX – „Wesoła"

Number of engines

2 pcs

Rated power

2 x 1,403 MWe

1,479 MWt

Number of boilers

4 pcs.

Boiler type and power

WR-10 - 11,6 MWt

WLM-5 - 5,8 MWt

PWPg-06 - 0,7 MWt

PWPg-06 - 0,7 MWt

Planned by ZEC S.A. in 2014 – 2018 years investments

developing network of installed gas engines with generators

and gas boilers for energetic use of methane

ZEC S.A.

division No. IX –

„Wesoła"

Number of engines

3 pcs.

Rated power

2 x 2,68 MWe

+

1,4 MWe

ZEC S.A.

division No. XII –

„Śląsk"

Number of engines

5 pcs

Rated power

5 x 1,48 MWe

+

Quantity of boilers

1 pc

Boiler power

6 MWth

ZEC S.A.

division No. VI -

„Wujek"

Number of engines

2 pcs

Rated power

2 x 1,48 MWe

ZEC S.A.

division No. V –

„Wieczorek”

Number of engines 1

pc

Rated power

1,48 MWe

Total methane utilization: ~ 60 mil. m3/year

It will cause reduction of greenhouse gases emission equivalent to ~ 1 mil tons of

CO2/year

ZEC S.A.

division No. IV –

„Murcki”

Number of engines

2 pcs

Rated power

2 x 1,48 MWe

Quantity of boilers

1 pc

Boiler power

6 MWth

Thank You for Your attention