Titelmasterformat durch Klicken bearbeiten
© CADFEM 2016
eCADFEM - Installation Setup Christian Meyer
Stefan Halbritter
06/2016
eCADFEM - Installation Setup (29-09-2016) 1
© CADFEM 2016
Content
eCADFEM - Installation Setup (29-09-2016) 2
Section 1 - Technical Information
Section 2 - Installation
Section 3 - Usage
About this document • Please read the document completely
• Navigate: follow the Links to go to the specific theme
• Navigate: return to the last viewed page by pressing Alt + Arrow towards left
© CADFEM 2016
Part 1 – Technical Information
eCADFEM - Installation Setup (29-09-2016) 3
Prerequisites
• Capability and Access
• Software, Network Connection (Ports)
• Usage Recommendations
• Dial-In Method: User Authentication
• Dial-In Method: IP
© CADFEM 2016
Section 1 – Technical Information – Capability and Access
eCADFEM - Installation Setup (29-09-2016) 4
Capability
• eCADFEM provides CAE licenses on demand, and based on a permanent internet
connection. The usage is charged against a prepaid contingent.
Access
• eCADFEM requires one of the following dial-in methods to communicate with the
eCADFEM Server:
• Permanent Public Firewall-IP (provided by the customer)
• Or a User Authentication (12 digit authentication, generated by the eCADFEM-Team)
• The 12-digit user authentication will be generated by the eCADFEM-Team in the event you
may not be able to provide a permanent, public firewall IP for your dial-in.
© CADFEM 2016
Section 1 – Technical Information – Software and Network Connection (Ports)
eCADFEM - Installation Setup (29-09-2016) 5
Software
• ANSYS Version 12 …. 17.2
• And/or: optiSLang (DYNARDO), Rocky DEM (ESSS)
Network Connection (Ports)
• Internet Connection
• Open the Ports 1056 and 2325 (ANSYS and Maxwell)
TCP
Outgoing only
• Open the Port 2020 (DYNARO optiSLang 5) or 1056 (ANSYS optiSLang 5.1.1)
TCP
Outgoing only
• Open the Port 1516 (Rocky DEM (ESSS))
TCP
Outgoing only
© CADFEM 2016
Section 1 – Technical Information – Usage Recommendations (1)
eCADFEM - Installation Setup (29-09-2016) 6
Regular Monitoring: Examine the usage by monitoring the inrements regularly. • Logging in on the password protected customer area on our eCADFEM Portal www.ecadfem.com
provides you the usage history as well as the very licenses that are currently checked out (Aktuelle Nutzung BETA, also to be monitored with the Viewer-Login). Please keep in mind that the sessions listed in the menue „Aktuelle Nutzung“ will be traceable after the licenses will have been used for several times. This is due to an automated rule compilation.
• Sessions: The day‘s session history is automatically cumulated at midnight and is listed in the customer area the next morning.
• Aktuelle Nutzung: The current usage is displayed with an offset of 5 minutes.
Unattended APDL-Jobs: „ANSYS Batch" Jobs recommeded • Please find this option in the Mechanical APDL Product Launcher at "Simulation Environment".
The allocation is limited to the duration of the calcuation procedure. This helps to avoid unattended license usage (e.g. by interactive ANSYS Mechanical sessions).
Permanent Connection: The permanent connection to the eCADFEM License Server is mandatory throughout the entire license usage. • Also, please make sure that your router settings for TCP-Aging are set to greater than 7200
seconds. Minor standard settings of e.g. 300 seconds may lead to overlapping responses.
Using the License Allocation of the ANSYS Prep/Post & Solver Licenses (effective since Sept. 01, 2016)
© CADFEM 2016
Section 1 – Technical Information – User Authentication
eCADFEM - Installation Setup (29-09-2016) 7
User Authentication
• This 12-digit user authentication is necessary, in the event no permanent, public IP-address
can be assigned by your Internet-Service-Provider.
• The authentication will be generated by the eCADFEM-Team and is included in the email
confirming your eCADFEM activation.
• To use eCADFEM with this authentication, your IT has to create a new (!) user-account with
according permissions (local or domain account) by naming it this very 12-digit
authentication.
• Using eCADFEM will only be able by signing in on the computer(s) with this 12-digit
authentication, but not with the regular user login. The authentication can be used for one or
even for multiple computers.
eCADFEM Server Client
Internet
© CADFEM 2016
Section 1 – Technical Information – IP Dial-In (1)
eCADFEM - Installation Setup (29-09-2016) 8
IP Dial-In
• The IP that will be registered for your account has to be permanent and public. Dynamic IP
addresses as well as private IP addresses cannot be routed and can therefore not be used for
eCADFEM.
• If you use Load-Balancing, all of the permanent, public IP addresses have to be registered.
• You have to operate an ANSYS License Server locally.
• Previous ANSYS Releases: The use of the most recent License Manager is recommended
even when using previous ANSYS releases.
Important: If you operate local ANSYS licenses too, the license key has to be examined prior to the
update to insure compatibility. License keys that are not in current maintenance, may not be able to be
utilized with the updated license manager.
If you have any considerations, you are welcome to contact our eCADFEM-Team at [email protected]
or our CADFEM Support-Teams
Client Ansysli (+ FlexLM) eCADFEM Server
Internet LAN
© CADFEM 2016
Section 1 – Technical Information – IP Dial-In (2)
eCADFEM - Installation Setup (29-09-2016) 9
Environments with IP Dial-In
• eCADFEM only
Use: only eCADFEM licenses are used
Operational: only an ansysli-Server is operated, but no FlexLM
• eCADFEM in combination with local ANSYS Licenses
Use: eCADFEM licenses are used in combination with licenses from a local license server
Operational: a complete license server (Ansysli- and FlexLM Server) is operated
Client Ansysli (+ FlexLM) eCADFEM Server
Internet LAN
© CADFEM 2016
Section 2 – Installation
eCADFEM - Installation Setup (29-09-2016) 10
Installation
• User Authentication
• IP Dial-In: eCADFEM only
• IP Dial-In: eCADFEM + local licenses in combination
• Using optiSLang/optiSLang inside Workbench
• Proxy Server
© CADFEM 2016
Section 2 - Installation – User Authentication
eCADFEM - Installation Setup (29-09-2016) 11
Prerequisites
• ANSYS Client Installation – 17.2 (or earlier)
• New (!) user (lokal or domain account)
• Check open ports for this user: (TCP) 1056 and 2325 and respectively 2020, 2021, 1516
• Insert entries in file %ANSYSLIC_DIR% \ ansyslmd.ini
%ANSLIC_DIR% = C:\Programms\Ansys Inc\Shared Files\Licensing
1056
2325
ansyslmd.ini:
Internet
eCADFEM Server
portal.ecadfem.com Client
User Account: EcadUserXY12
principal setup
© CADFEM 2016
Section 2 - Installation – IP Dial-In – eCADFEM only (1)
eCADFEM - Installation Setup (29-09-2016) 12
Prerequisites
• ANSYS Client Installation – 17.2 (or earlier)
• Local ANSYS License Server, with ANSYSLI_SERVER only
• Check open ports : (TCP) 1056 and 2325 and respectively 2021, 1516
• Insert entries in file %ANSYSLIC_DIR%\ ansyslmd.ini
%ANSLIC_DIR% = C:\Programms\Ansys Inc\Shared Files\Licensing
• Definition of an environment variable
Client Local Server:
Ansysli
LAN
1056
2325
Internet
eCADFEM Server
portal.ecadfem.com
Public IP Adress: ###.###.###.###
1056
2325
Next page
principal setup
© CADFEM 2016
Section 2 - Installation – IP Dial-In – eCADFEM only (2)
eCADFEM - Installation Setup (29-09-2016) 13
Entries in file %ANSYSLIC_DIR%\ansyslmd.ini (usually) %ANSLIC_DIR% = C:\Programms\Ansys Inc\Shared Files\Licensing
Definition of an environment variable environment variable (SYSTEM): FNP_IP_ENV=1
Definition of the global environment variable (SYSTEM):
FNP_IP_ENV=1 + ansyslmd.ini:
ANSYSLI_IP_OVERRIDE ANSYSLI_NOFLEX=1 ANSYSLI_SERVERS=2325@IhrServerHostname [email protected] [email protected]
Server:
ansyslmd.ini:
ANSYSLI_SERVERS=2325@IhrServerHostname [email protected] [email protected]
Client:
© CADFEM 2016
Section 2 - Installation – IP Dial-In – eCADFEM + local licenses (1)
eCADFEM - Installation Setup (29-09-2016) 14
Prerequisites
• ANSYS Client Installation – 17.2 (or earlier)
• Local ANSYS License Server (Ansysli + FlexLM)
• Check open ports : (TCP) 1056 and 2325 and respectively 2020, 2021, 1516
• Insert entries in file %ANSYSLIC_DIR%\ ansyslmd.ini
(usually) %ANSLIC_DIR% = C:\Programms\Ansys Inc\Shared Files\Licensing
• Definition of an environment variable
Client Local Server:
Ansysli + FlexLM
LAN
1056
2325
Internet
eCADFEM Server
portal.ecadfem.com
Public IP Adress: ###.###.###.###
1056
2325
Next page
principal setup
© CADFEM 2016
Section 2 - Installation – IP Dial-In – eCADFEM + local licenses (2)
eCADFEM - Installation Setup (29-09-2016) 15
Entries in file %ANSYSLIC_DIR%\ansyslmd.ini (usually) %ANSLIC_DIR% = C:\Programms\Ansys Inc\Shared Files\Licensing
Definition of a global environment variable Environment variable (SYSTEM): FNP_IP_ENV=1
Definition of the global environment variable (SYSTEM):
FNP_IP_ENV=1 +
ansyslmd.ini:
ANSYSLI_IP_OVERRIDE SERVER=1055@lokalerLicServerHostname ANSYSLI_SERVERS=2325@lokalerLicServerHostname [email protected] [email protected]
Server:
ansyslmd.ini:
SERVER=1055@lokalerLicServerHostname ANSYSLI_SERVERS=2325@IhrServerHostname [email protected] [email protected]
Client:
© CADFEM 2016
Section 2 – Installation – Using optiSLang / ANSYS optiSLang
eCADFEM - Installation Setup (29-09-2016) 16
ANSYS OptiSlang (starting with 5.1.1)
• Open the TCP Port 1056, outgoing only
OptiSLang 5 or before
• Open the TCP Port 2020, outgoing only
• Settings within the application OptiSLang
Specifying the license server by *.lic-file.
Create the file during installation on C:\ (C:\Programms\optislang_x.y.z\flowguide\license)
example for filename: license.lic
Content (example):
# License for OptiSLang
# Customer:
# Comment: ecadfem-Portal License
SERVER portal.ecadfem.com 00d0b7901800 2020
USE_SERVER
VENDOR sc_ag
© CADFEM 2016
Section 2 – Installation - Proxy-Server (TCP only)
eCADFEM - Installation Setup (29-09-2016) 17
ANSYS licensing does not support proxy-server for the time being
• Therefore, the ANSYS application via proxy server can only be done by a transparent port
forwarding.
• The incoming ANSYS client requests from the proxy server are directly forwarded to the
hostname of the eCADFEM-Portal (portal.ecadfem.com). The forwarding is done through
the TCP-Protocol (1056/2325).
• HTTP-Proxy forwarding is not possible.
• The response returns to higher ports, which are already opened for standard
communication. (Backroute has to be possible)
© CADFEM 2016
Section 3 – Usage
eCADFEM - Installation Setup (29-09-2016) 18
Test
How to use the PrepPost – Solver License Allocation
• Workbench Settings
• RSM Settings
• Mechanical Editor Settings
• Project Schematic Settings
• Start Solution
How to avoid unattended usage
Prioritize eCADFEM towards local licenses
Diagnosis
Potential sources of error/malfunction
© CADFEM 2016
Section 3 – Usage - Test
eCADFEM - Installation Setup (29-09-2016) 19
Functional Test
• Start Mechanical APDL
• Start a Workbench-Project, i.e. Mechanical Editor has to be open
The checked-out license is listed in the headline in sqare brackets
Prioritizing a local license can not be guaranteed in general
• Work-Arounds for selective license addressing
The order in which the licenses are addressed depends on
• The accessibility to the server respectively the response time of the local server compared
to the eCADFEM Server.
• And the hierarchy in the License Preferences (License Presettings)
© CADFEM 2016
Section 3 – How to use the PrepPost – Solver License Allocation
eCADFEM - Installation Setup (29-09-2016) 20
ANSYS Mechanical license change as of Sept. 1, 2016
• ANSYS Mechanical Enterprise (ansys)
was splitted into:
ANSYS Mechanical Enterprise PrepPost (preppost) +
+ ANSYS Mechanical Enterprise Solver (meba)
ANSYS Workbench: Modified procedure on the client
• Mandatory settings
in ANSYS Workbench
in RSM (Remote Solve Manager)
in ANSYS Mechanical Editor– Solve Process Settings
• Solve
Out of the Mechanical Editor
Out of the Project Site
© CADFEM 2016
Section 3 – PrepPost – Solver Licenses: Workbench Settings (1)
eCADFEM - Installation Setup (29-09-2016) 21
The following setting releases the PrepPost License promptly after
completion (cost optimization)
• Extras Options Mechanical: Release License for Pending Jobs = Always
© CADFEM 2016
Section 3 – PrepPost – Solver Licenses: Workbench Settings (2)
eCADFEM - Installation Setup (29-09-2016) 22
License Preferences
• PrepPost Tab: ANSYS Mechanical Enterprise PrepPost prioritize as topmost
• Solver Tab: ANSYS Mechanical Enterprise PrepPost prioritize as topmost as well
• Solver Tab: ANSYS Mechanical Enterprise Solver right beneath
Also depending, if either a local or an eCADFEM license is requested, the according license has to be prioritized as topmost. In this regard, the Mechanical Editor uses the settings from the Solver Tab
© CADFEM 2016
Section 3 – PrepPost – Solver Licenses: RSM Settings (1)
eCADFEM - Installation Setup (29-09-2016) 23
Solve Manager (RSM) Properties
• Open the RSM Admin Window:
START All Programs ANSYS 17.2 Remote Solve Manager RSM 17.2
• Right Mouse Button on My Computer
My Computer Set Password
• Enter Password (password for the suggested user)
• Remain until the Set Password window fades
My Computer Properties: Project Directory
• Create a directory on a local data partition
• Enter this new directory as Project Directory
© CADFEM 2016
Section 3 – PrepPost – Solver Licenses: RSM Settings (2)
eCADFEM - Installation Setup (29-09-2016) 24
Compute Server Properties
• Right Mouse Button on Compute-Server localhost Properties
Working Directory Location: User Specified
Working Directory Path: enter the path
used for the Project Directory
Enlarge the window by clicking on more if needed
Set Maximum Number of Jobs on 1
© CADFEM 2016
Section 3 – PrepPost – Solver Licenses: Mechanical Editor Settings (1)
eCADFEM - Installation Setup (29-09-2016) 25
Solve Process Settings in the Mechanical Editor
• Tools Sole Process Settings… My Computer (Background):
License: ANSYS Mechanical Enterprise Solver
© CADFEM 2016
Section 3 – PrepPost – Solver Licenses: Mechanical Editor Settings (2)
eCADFEM - Installation Setup (29-09-2016) 26
Advanced Solver Properties (optional)
• Tools Solve Process Settings…
My Computer (Background): Advanced Properties…
Select Distribute Solution (if possible)
(= distributed (DMP))
Max. number of utilized cores: n (= Number of all CPU-Cores for Solution)
• ANSYS Mechanical Enterprise Solver occupies 2 cores (Standard)
• ANSYS HPC-Packs:
n < = 8 requires 1 HPC-Pack
n > 8 < = 32 require 2 HPC-Packs
n > 33 < = 128 require 3 HPC-Packs
License Queuing: Wait for Available License: selection not
mandatory for eCADFEM
© CADFEM 2016
Section 3 – PrepPost – Solver Licenses: Project Settings
eCADFEM - Installation Setup (29-09-2016) 27
Analysis System Settings: Update Option: Submit to Remote Solve Manager
Solve Process Setting: My Computer, Background
© CADFEM 2016
Section 3 – PrepPost – Solver Licenses: Start Solution
eCADFEM - Installation Setup (29-09-2016) 28
Start the Solution out of the Mechanical Editor
• PrepPost License remains occupied during the Solution
• Especially suitable for short-term solutions
• Start the Solution: Solve My Computer (Background)
Start the Solution out of the Project
• PrepPost License is only occupied for a short time
• Start the Solution
Unique Analysis
• Right Mouse Button on Solution Update
Combined Analysis
• Update
All combined analysis get updated
© CADFEM 2016
Section 3 – How to avoid unattended usage
eCADFEM - Installation Setup (29-09-2016) 29
Unattended license usage may occur if
• Mechanical maintained active after the usage
• Batch Solve
• Or if processes have not been finished correctly
Monitoring of active licenses
• The Task Manager shows active ANSYS / CFX processes
ANSYS.exe
AnsMeshingServer.exe
AnsysWBU.exe
AnsysFWW.exe
• Important: unfinished processes can block returning the license correctly
• Python Scripts out of the project: please check the processes after completing the ANSYS
Workbench
PreEngine.exe
PreGui.ogl.exe
Cfx5pre.exe*32
SolverManager.exe
Cfx5solve.exe*32
PostEngine.exe
PostGui.ogl.exe
Cfx5post.exe*32
© CADFEM 2016
Section 3 – Prioritize eCADFEM towards local licenses
eCADFEM - Installation Setup (29-09-2016) 30
The sole usage of eCADFEM licenses can be executed with specific Start Scripts
• Using those Start Scripts opresses the licenses from the local license server
• If a local ANSYSLI_SERVER is operated (IP Dial-In), the local hostname of the ANSYSLI_SERVERS has to be prioritzied i.e. to be listed first. E.g.: set ANSYSLI_SERVERS=2325@lokaleransysliserver;[email protected]
Start script for Windows
• ANSYS 17.1 APDL: @echo off set [email protected] set [email protected] set ANS_FLEXLM_DISABLE_DEFLICPATH=1 "%AWP_ROOT171%\CommonFiles\TCL\bin\%ANSYS_SYSDIR%\wish.exe" "%AWP_ROOT171%\CommonFiles\Launcher\launchermain.itcl“
• ANSYS Workbench 17.1: @echo off
set ANS_FLEXLM_DISABLE_DEFLICPATH=1
"%AWP_ROOT171%\Framework\bin\win64\runwb2.exe"
© CADFEM 2016
Section 3 – Diagnosis
eCADFEM - Installation Setup (29-09-2016) 31
Verify the file entries in %ANSYSLIC_DIR%\ansyslmd.ini
Verify the outgoing ports
• in cmd-Shell:
telnet portal.ecadfem.com 1056
telnet portal.ecadfem.com 2325
• Output:
If you receive an error, the port may be blocked
This test does not verify any further restrictions within the Firewall communication.
Further blockings can be verified by deactivating the Firewall temporarily (if possible)
Processes in the Windows Task Manager
• ansysli_server.exe
• ansysli_monitor.exe
Any further questions please contact us at [email protected]
• Please include the following information in your email:
Diagnosis of the ANSLIC_ADMIN Utility as a file
ANSYS License Management Center > Diagnostics > Gather Diagnostic Information > Save To File
© CADFEM 2016
Section 3 – Potential sources of error/malfunction (1)
eCADFEM - Installation Setup (29-09-2016) 32
Please verify wether all prerequisites are fulfilled
Most local obstacles are:
• IP Dial-In
The registered IP address is not transmitted or your dial-in is executed with a different IP
Please have your IT check the permanent, public IP of your Firewall
Verify the setting of the Environment Variable FNP_IP_ENV=1
Verify the entry of the local Ansysli Servers in the ansyslmd.ini
• Blocking of the local ANSYS license components by a local Security Software (
[Windows] Firewall / Enpoint Protection, etc.)
Solution: allow communication for blocked programs
• Blocking of mandatory Ports by local Security Software (Windows Firewall !)
Solution: activate blocked Ports
• portal.ecadfem.com nor properly resolved in DNS
Solution: apply correct DNS settings respectively by static host-file entry
• License Preferences are set incorrectly
Solution: move one of the activated eCADFEM products to the topmost in the License Preferences,
and restart the application
© CADFEM 2016
Section 3 – Potential sources of error/malfunction (2)
eCADFEM - Installation Setup (29-09-2016) 33
Setting the Timeout of the ANSYSLI
• In the event, eCADFEM does start only after a Reread of the local ANSYSLI-Server,
please check the %ANSYSLIC_DIR%\ansysli_server.log for the following entry:
Unable to connect to FLEXlm path [email protected]; adding to "Unavailable
FLEXlm Servers" cache.
• This message describes, that the Licensing Interconnect temporarily has not achieved a
connection to the eCADFEM Server during the standard interval. And has therefore
deleted it from the license path. Restarting the ANSYSLI-Server will make eCADFEM
availlable again
• To avoid this error, please increase the Timeout with the following, additioal argument in
the file "ansyslmd.ini„:
ANSYSLI_TIMEOUT_FLEXLM=15