Upload
hoangcong
View
280
Download
9
Embed Size (px)
Citation preview
EBARA Submersible Sewage Pumps DLFU
Contents
Project: Model: Chk’d: Date:
Model DLFU
50DLFU61.580DLFU61.580DLMFU61.580DLFU62.280DLMFU62.280DLFU63.780DLMFU63.780DLFU65.580DLMFU65.580DLFU67.580DLCMFU67.580DLFU61180DLCMFU61180DLFU61580DLFU61880DLFU622
100DLFU61.5100DLFU62.2100DLMFU62.2100DLFU63.7100DLMFU63.7100DLFU65.5100DLMFU65.5 100DLFU67.5100DLMFU67.5 100DLFU611100DLMFU611100DLFU615100DLMFU615 100DLFU618100DLMFU618100DLFU622100DLMFU622100DLFU630
100DLFU637100DLFU645150DLFU67.5150DLFU611150DLFU615150DLFU618150DLFU622150DLFU630150DLFU637150DLFU645200DLFU67.5200DLFU611200DLFU615200DLFU618200DLFU622200DLFU630200DLFU637200DLFU645
250DLFU611250DLBFU615250DLCFU615250DLFU618250DLFU622250DLFU630250DLFU637250DLFU645300DLFU618300DLFU622300DLFU630300DLFU637300DLFU645
Section Page
Specifications 2-158
Selection Chart 2-165
Performance Curves 2-166
Outline Drawings 2-191
Sectional View 2-210
QDC Information 2-278
Technical Information 2-289.1material specificationimpeller descriptionmotor protectioncable entrypaint specificationsmechanical sealgeneral
Motor Data 2-315.1motor electrical specificationscable datawiring diagrams
motor electrical data
EBARA Fluid Handlingwww.pumpsebara.com 2-155(t) 803 327 5005 • (f) 803 327 5097 rev. 11/02
EBARA Submersible Sewage Pumps DLFU
Contents
Project: Model: Chk’d: Date:
EBARA Fluid Handlingwww.pumpsebara.com 2-156(t) 803 327 5005 • (f) 803 327 5097 rev. 01/02
EBARA Submersible Sewage Pumps DLFU
Model Designation
Project: Model: Chk’d: Date:
DISCHARGE SIZE – mm
50mm – 2" 200mm – 8"
80mm – 3" 250mm – 10"
100mm – 4" 300mm – 12"
150mm – 6"
MODEL TYPE
DLF/DLMF – submersible sewage pump
DLFM/DLMFM – FM explosion proof designation
GEOGRAPHIC DESIGNATION
U – U.S.A. market
HERTZ
6 - 60
RATED KW
1.5 – 2HP 7.5 – 10HP 22 – 30HP
2.2 – 3HP 11 – 15HP 30 – 40HP
3.7 – 5HP 15 – 20HP 37 – 50HP
5.5 – 71/2HP 18 – 25HP 45 – 60HP
PHASE
none – three phase
VOLTAGE
2 - 208/230
4 - 460
5 - 575
100DLF/DLMF
U 6 1.5 2
EBARA Fluid Handlingwww.pumpsebara.com 2-157(t) 803 327 5005 • (f) 803 327 5097 rev. 01/02
EBARA Submersible Sewage Pumps DLFU
Specifications
Project: Model: Chk’d: Date:
Model DLFUSpecifications
Standard Optional
Size 2, 3, 4, 6, 8, 10, 12 inch
Range of HP 2 to 60 HP
Range of Performance Capacity 13 to 4000 GPMHead 7 to 243 feet
Limitation
Maximum Water Temperature 104°F ( 40°C)
Synchronous Speed 1800 RPM
MaterialsCasing Cast IronImpeller Cast Iron (2 to 60HP)
Ductile Iron (150-300 DLFU 40 to 60 HP)Shaft 403 Stainless Steel (2 to 5HP)
420 Stainless Steel (71/2 to 60HP)Motor Frame Cast IronFastener 304 Stainless Steel
Mechanical Seal Double Mechanical SealMaterial – Upper Side Carbon/Ceramic (2 to 60HP) Tungsten Carbide/Tungsten CarbideMaterial – Lower Side Silicon Carbide/Silicon Carbide (2 to 60HP) Tungsten Carbide/Tungsten Carbide
Tungsten Carbide/Tungsten Carbide (150-300 DLFU50 and 60HP only)
Impeller Type Semi-open (2 to 30HP)Enclosed (40 to 60HP)
Bearing Prelubricated Ball Bearing
Motor Insulation Class F (2-5HP), H (71/2 to 60HP) FM Explosion Proof, Class 1, Three Phase 208/230/460V Division 1, Group C, D
Service Factor 1.15
Motor Protection Thermal Detector – KlixonsMechanical Seal Leakage Detector – Float Switch
Submersible cable 33 ft. (2 to 5HP) ____ ft. (customer specified)50 ft. (71/2 to 60HP)
Accessories QDC System
EBARA Fluid Handlingwww.pumpsebara.com 2-158(t) 803 327 5005 • (f) 803 327 5097 rev. 02/13
EBARA Submersible Sewage Pumps DLFU
Specifications
Project: Model: Chk’d: Date:
EBARA Fluid Handlingwww.pumpsebara.com 2-159(t) 803 327 5005 • (f) 803 327 5097 rev. 10/11
A. General:Provide submersible sewage pumps suitable for continuous duty operation underwater without loss of watertight integrity to a depth of 65 feet. Pump system design shall include a guide rail system be such that the pump will be automatically connected to the discharge piping when lowered into place on the discharge connection. The pump shall be easily removable for inspection or service, requiring no bolts, nuts, or other fasteners to be disconnected, or the need for personnel to enter the wet well. The motor and pump shall be designed, manufactured, and assembled by the same manufacturer.
B. Manufacturer:EBARA International Corporation
C. Pump Characteristics: Pumps shall conform to the following requirements:
Number of unitsDesign flow (gpm)Design TDH (ft)Minimum shut off head (ft)RPM 1800Maximum HPMinimum efficiency at design (%)Minimum power factor at design (%)Voltage/HZ 208/230V, 460V / 60Phase 3
1. Impellers:a. For units 2 to 5 HP, the impeller shall be radial single or multi-vane, semi-open design. It shall be dynamically
balanced and shall be designed for solids handling with a long thrulet without acute turns. The inlet edge of theimpeller vanes shall be angled toward the impeller periphery so as to facilitate the release of objects that mightotherwise clog the pump. The 2 to 5 HP impeller design shall also include back pump out vanes to reduce thepressure and entry of foreign materials into the mechanical seal area. In addition, a lip seal shall be locatedbehind the impeller hub to further reduce the entry of foreign materials into the seal area. Impellers shall be directconnected to the motor shaft with a slip fit, key driven, and secured with an impeller bolt. The design shall includea replaceable cast iron suction cover. The suction cover shall be designed such that it may be adjusted to maintainworking clearances and hydraulic efficiencies.
b. For units 71/2 to 30 HP, the impeller shall be a mixed flow multi-vane semi-open design. It shall be dynamicallybalanced and shall be designed for solids handling with a long thrulet without acute turns. The inlet edge of theimpeller vanes shall be angled toward the impeller periphery so as to facilitate the release of objects that mightotherwise clog the pump. The 71/2 to 30 HP impeller design shall also include back pump out vanes to reduce thepressure and entry of foreign materials into the mechanical seal area. In addition, a lip seal shall be locatedbehind the impeller hub to further reduce the entry of foreign materials into the seal area. Impellers shall be direct
D. Pump Construction:All major parts of the pumping unit(s) including casing, impeller, suction cover, wear rings, motor frame and dischargeelbow shall be manufactured from gray cast iron, ASTM A-48 Class 30. Castings shall have smooth surfaces devoid of blow holes or other casting irregularities. Casing design shall be centerline discharge with a large radius on the cut water to prevent clogging. Units shall be furnished with a discharge elbow and 125 lb. flat face ANSI flange. All exposed bolts and nuts shall be 304 stainless steel. All mating surfaces of major components shall be machined and fitted with NBR o-rings where watertight sealing is required. Machining and fitting shall be such that sealing is accomplished by automatic compression of o-rings in two planes and o-ring contact is made on four surfaces without the requirement of specific torque limits. Internal and external surfaces are prepared to SSPC-VIS1-3-63 then coated with a zinc-rich epoxy primer. The external surfaces are then coated with an H.B. Teneme-Tar 46-413 coal tar epoxy.
EBARA Submersible Sewage Pumps DLFU
Specifications
Project: Model: Chk’d: Date:
EBARA Fluid Handlingwww.pumpsebara.com 2-160(t) 803 327 5005 • (f) 803 327 5097 rev. 10/11
connected to the motor shaft with a slip fit, key driven, and secured with an impeller bolt. The design shall include a replaceable cast iron suction cover. The suction cover shall be designed such that it may be adjusted to maintain working clearances and hydraulic efficiencies.
c. For high head units with 4'' discharge, 40 to 60 HP shall have a radial multi-vane, enclosed impeller design. Itshall be dynamically balanced and shall be designed for solids handling with a long thrulet without acute turns.The inlet edge of the impeller vanes shall be angled toward the impeller periphery so as to facilitate the releaseof objects that might otherwise clog the pump. A lip seal shall be located behind the impeller hub to reduce theentry of foreign materials into the mechanical seal area. Impellers shall be direct connected to the motor shaftwith a slip fit, key driven, and secured with an impeller bolt. The design shall include a replaceable casing wearring at the pump suction to maintain working clearances and hydraulic efficiencies.
d. For units 6'' to 12'' discharge sizes, 40 to 60 HP, the impeller shall be a mixed flow multi-vane enclosed design. Itshall be dynamically balanced and shall be designed for solids handling with a long thrulet without acute turns.The inlet edge of the impeller vanes shall be angled toward the impeller periphery so as to facilitate the releaseof objects that might otherwise clog the pump. A lip seal shall be located behind the impeller hub to reduce theentry of foreign materials into the seal area. Impellers shall be direct connected to the motor shaft with a slip fit,key driven, and secured with an impeller bolt. The design shall include a replaceable casing wear ring at thepump suction to maintain working clearances and hydraulic efficiencies.
optional K-series design:e. For units 2 to 5 HP, the impeller shall be radial single or multi-vane, semi-open design. It shall be dynamically
balanced and shall be designed for solids handling with a long thrulet without acute turns. The inlet edge of theimpeller vanes shall be angled toward the impeller periphery so as to facilitate the release of objects that mightotherwise clog the pump. The 2 to 5 HP impeller design shall also include back pump out vanes to reduce thepressure and entry of foreign materials into the mechanical seal area. In addition, a lip seal shall be located behindthe impeller hub to further reduce the entry of foreign materials into the seal area. Impellers shall be direct connectedto the motor shaft with a slip fit, key driven, and secured with an impeller bolt. The design shall include a replaceablecast iron suction cover. The suction cover shall contain a groove(s) perpendicular to the suction opening to disruptfibrous solids that may otherwise become lodged between the impeller and suction cover. The suction cover shallbe designed such that it may be adjusted to maintain working clearances and hydraulic efficiencies.
f. For units 71/2 to 30 HP, the impeller shall be a mixed flow multi-vane semi-open design. It shall be dynamicallybalanced and shall be designed for solids handling with a long thrulet without acute turns. The inlet edge of theimpeller vanes shall be angled toward the impeller periphery so as to facilitate the release of objects that mightotherwise clog the pump. The 71/2 to 30 HP impeller design shall also include back pump out vanes to reduce thepressure and entry of foreign materials into the mechanical seal area. In addition, a lip seal shall be locatedbehind the impeller hub to further reduce the entry of foreign materials into the seal area. Impellers shall be directconnected to the motor shaft with a slip fit, key driven, and secured with an impeller bolt. The design shall includea replaceable cast iron suction cover. The suction cover shall contain a groove(s) perpendicular to the suction openingto disrupt fibrous solids that may otherwise become lodged between the impeller and suction cover.The suctioncover shall be designed such that it may be adjusted to maintain working clearances and hydraulic efficiencies.
2. Mechanical Sealsa. For units 2 to 5 HP, double mechanical seals operating in an oil bath shall be provided on all units. The oil filled
seal chamber shall be designed to prevent over-filling and include an anti-vortexing vane to insure proper lubricationof both seal faces. Lower face materials shall be silicon carbide, upper faces carbon vs. ceramic, NBR elastomers,and 304SS hardware. Seal system shall not rely on pumping medium for lubrication.
b. Units 71/2 to 60 HP shall be designed to include a double mechanical seal in a tandem arrangement. Each sealshall be positively driven and act independently with its own spring system. The upper seal operates in an oilbath, while the lower seal is lubricated by the oil from between the shaft and the seal faces, and in contact with
EBARA Submersible Sewage Pumps DLFU
Specifications
Project: Model: Chk’d: Date:
EBARA Fluid Handlingwww.pumpsebara.com 2-161(t) 803 327 5005 • (f) 803 327 5097 rev. 10/11
the pumpage. The oil filled seal chamber shall be designed to prevent over-filling and include an anti-vortexing vane to insure proper lubrication of both seal faces. Lower face materials shall be silicon carbide (tungsten carbidefor 150-300 DLF 50 & 60 HP only), upper faces carbon vs. ceramic, NBR elastomers, and 304SS hardware. Seal system shall not rely on pumping medium for lubrication.
Power cable jacket shall be manufactured of an oil resistant chloroprene rubber material, designed for submerged applications. Cable shall be watertight to a depth of a least 65'. The cable entry system shall comprise of primary, secondary, and tertiary sealing methods. The primary seal shall be achieved by a cylindrical elastomeric grommetcompressed between the motor cover and a 304SS washer. Secondary sealing is accomplished with a compressed o-ring made of NBR material. Compression and subsequent sealing shall preclude specific torque requirements. Thesystem shall also include tertiary sealing to prevent leakage into the motor housing due to capillary action through theinsulation if the cable is damaged or cut. The cable wires shall be cut, stripped, re-connected with a copper butt end connector, and embedded in epoxy within the cable gland. This provides a dead end for leakage through the cable insulation into the motor junction area. The cable entry system shall be the same for both the power and control cables.
F. Guide Rail system:Design shall include two (2) 304SS schedule 40 guide rails sized to mount directly to the quick discharge connector, QDC, at the floor of the wetwell and to a guide rail bracket at the top of the wetwell below the hatch opening, (refer to project drawings). Intermediate guide brackets are recommended for rail lengths over 15 feet.
Guide rails are not part of the pump package and shall be supplied by others.
The QDC shall be manufactured of cast iron, ASTM A48 Class 30. It shall be designed to adequately support the guide rails, discharge piping, and pumping unit under both static and dynamic loading conditions with support legs that are suitable for anchoring it to the wetwell floor. The face of the inlet QDC flange shall be perpendicular to the floor of the wetwell. The discharge flange of the QDC shall conform to ANSI B16.1 Class 125.
The pump design shall include an integral self-aligning sliding bracket. Sealing of the pumping unit to the QDC shall be accomplished by a single, linear, downward motion of the pump. The entire weight of the pump unit shall be guidedto and wedged tightly against the inlet flange of the QDC, making metal to metal contact with the pump discharge forming a seal without the use of bolts, gaskets or o-rings.
A stainless steel lifting chain of adequate length for removing and installing the pump unit is recommended. The chain shall have a round link with a 2-1/4'' inside diameter every two feet. This link will allow for a sliding pinch bar through the link to pick the chain, more than once if necessary, at multiple intervals during pump removal and installation.
The pump motor shall be an air filled induction type with a squirrel cage rotor, shell type design, built to NEMA MG-1, Design B specifications. Stator windings shall be copper, insulated with moisture resistant Class H insulation (Class F for 2-5HP). The stator shall be dipped and baked three times in Class H varnish (Class F for 2-5HP) and heat shrunk fitted into the stator housing. Rotor bars and short circuit rings shall be manufactured of cast aluminum. Motor shaft shall be one piece AISI403 for 2 to 5 HP, AISI420 for 7 1/2 to 60 HP, rotating on two permanently lubricated ball bearings designed for a minimum B-10 life of 60,000 hours. Motor service factor shall be 1.15 and capable of up to 20 starts per hour. The motor shall be designed for continuous duty pumping at a maximum sump temperature of 104°F. Voltage and frequency tolerances shall be a maximum 10 / 5% respectively. Motor over temperature protection shall be provided by miniature thermal protectors embedded in the windings. Mechanical seal failure protection shall be provided by a mechanical float switch located in a chamber above the seal. This switch shall be comprised of a magnetic float that actuates a dry reed switch encapsulated within the stem. Should the mechanical seal fail, liquid shall be directed into the float chamber, in which the rising liquid activates the switch opening the normally closed circuit. For units 2 to 30 HP the float body and float shall be a polypropylene material with a 316SS stopper. Units 40 HP and greater, the float switch components shall be 304SS. The motor shall be non-overloading over the entire specified range of operation and be able to operate at full load intermittently while unsubmerged without damage to the unit.
E. Motor Construction:
EBARA Submersible Sewage Pumps DLFMU–Explosion Proof Non-clog
Specifications
Project: Model: Chk’d: Date:
EBARA Fluid Handlingwww.pumpsebara.com 2-162(t) 803 327 5005 • (f) 803 327 5097 rev. 10/11
A. General:Provide FM explosion proof submersible non clog sewage pumps suitable for continuous duty operation underwater without loss of watertight integrity to a depth of 65 feet. Pump system design shall include a guide rail system be such that the pump will be automatically connected to the discharge piping when lowered into place on the dis-charge connection. The pump shall be easily removable for inspection or service, requiring no bolts, nuts, or other fasteners to be disconnected, or the need for personnel to enter the wet well. The motor and pump shall be designed, manufactured, and assembled by the same manufacturer.
B. Manufacturer:EBARA International Corporation
C. Pump Characteristics: Pumps shall conform to the following requirements:
Number of unitsDesign flow (gpm)Design TDH (ft)Minimum shut off head (ft)RPM 1800Maximum HPMinimum efficiency at design (%)Minimum power factor at design (%)Voltage/HZ 208/230V, 460V / 60Phase 3
1. Impellers:a. For units 2 to 5HP, the impeller shall be single or radial multi-vane, semi-open design. It shall be dynamically balanced
and shall be designed for solids handling with a long thrulet without acute turns. The inlet edge of the impellervanes shall be angled toward the impeller periphery so as to facilitate the release of objects that might otherwiseclog the pump. The 2 to 5 HP impeller design shall also include back pump out vanes to reduce the pressure andentry of foreign materials into the mechanical seal area. In addition, a lip seal shall be located behind the impellerhub to further reduce the entry of foreign materials into the seal area. Impellers shall be direct connected to themotor shaft with a slip fit, key driven, and secured with an impeller bolt. The design shall include a replaceablecast iron suction cover. The suction cover shall be designed such that it may be adjusted to maintain workingclearances and hydraulic efficiencies.
b. For units 71/2 to 30 HP, the impeller shall be a mixed flow multi-vane semi-open design. It shall be dynamicallybalanced and shall be designed for solids handling with a long thrulet without acute turns. The inlet edge of theimpeller vanes shall be angled toward the impeller periphery so as to facilitate the release of objects that mightotherwise clog the pump. The 71/2 to 30 HP impeller design shall also include back pump out vanes to reduce thepressure and entry of foreign materials into the mechanical seal area. In addition, a lip seal shall be locatedbehind the impeller hub to further reduce the entry of foreign materials into the seal area. Impellers shall be direct
D. Pump Construction:All major parts of the pumping unit(s) including casing, impeller, suction cover, wear rings, motor frame and dischargeelbow shall be manufactured from gray cast iron, ASTM A-48 Class 30. Castings shall have smooth surfaces devoid of blow holes or other casting irregularities. Casing design shall be centerline discharge with a large radius on the cut water to prevent clogging. Units shall be furnished with a discharge elbow and 125 lb. flat face ANSI flange. All exposed bolts and nuts shall be 304 stainless steel. All mating surfaces of major components shall be machined and fitted with NBR o-rings where watertight sealing is required. Machining and fitting shall be such that sealing is accomplished by automatic compression of o-rings in two planes and o-ring contact is made on four surfaces withoutthe requirement of specific torque limits. Internal and external surfaces are prepared to SSPC-VIS1-3-63 then coated with a zinc-rich epoxy primer. The external surfaces are then coated with a H.B. Teneme-Tar 46-413 coal tar epoxy.
EBARA Submersible Sewage Pumps DLFMU–Explosion Proof Non-clog
Specifications
Project: Model: Chk’d: Date:
EBARA Fluid Handlingwww.pumpsebara.com 2-163(t) 803 327 5005 • (f) 803 327 5097 rev. 10/11
connected to the motor shaft with a slip fit, key driven, and secured with an impeller bolt. The design shall include a replaceable cast iron suction cover. The suction cover shall be designed such that it may be adjusted to maintainworking clearances and hydraulic efficiencies.
c. For high head units, 4'' discharge, 40 to 60 HP shall have a radial multi-vane, enclosed impeller design. It shallbe dynamically balanced and shall be designed for solids handling with a long thrulet without acute turns. Theinlet edge of the impeller vanes shall be angled toward the impeller periphery so as to facilitate the release ofobjects that might otherwise clog the pump. A lip seal shall be located behind the impeller hub to reduce the entryof foreign materials into the mechanical seal area. Impellers shall be direct connected to the motor shaft with aslip fit, key driven, and secured with an impeller bolt. The design shall include a replaceable casing wear ring atthe pump suction to maintain working clearances and hydraulic efficiencies.
d. For units 6'' to 12'' discharge sizes, 40 to 60 HP, the impeller shall be a mixed flow multi-vane enclosed design. Itshall be dynamically balanced and shall be designed for solids handling with a long thrulet without acute turns.The inlet edge of the impeller vanes shall be angled toward the impeller periphery so as to facilitate the releaseof objects that might otherwise clog the pump. A lip seal shall be located behind the impeller hub to reduce theentry of foreign materials into the seal area. Impellers shall be direct connected to the motor shaft with a slip fit,key driven, and secured with an impeller bolt. The design shall include a replaceable casing wear ring atthe pump suction to maintain working clearances and hydraulic efficiencies.
optional K-series design:e. For units 2 to 5HP, the impeller shall be single or radial multi-vane, semi-open design. It shall be dynamically balanced
and shall be designed for solids handling with a long thrulet without acute turns. The inlet edge of the impellervanes shall be angled toward the impeller periphery so as to facilitate the release of objects that might otherwiseclog the pump. The 2 to 5 HP impeller design shall also include back pump out vanes to reduce the pressure andentry of foreign materials into the mechanical seal area. In addition, a lip seal shall be located behind the impellerhub to further reduce the entry of foreign materials into the seal area. Impellers shall be direct connected to themotor shaft with a slip fit, key driven, and secured with an impeller bolt. The design shall include a replaceablecast iron suction cover. The suction cover shall contain a groove(s) perpendicular to the suction opening to disruptfibrous solids that may otherwise become lodged between the impeller and suction cover. The suction cover shallbe designed such that it may be adjusted to maintain working clearances and hydraulic efficiencies.
f. For units 71/2 to 30 HP, the impeller shall be a mixed flow multi-vane semi-open design. It shall be dynamicallybalanced and shall be designed for solids handling with a long thrulet without acute turns. The inlet edge of theimpeller vanes shall be angled toward the impeller periphery so as to facilitate the release of objects that mightotherwise clog the pump. The 71/2 to 30 HP impeller design shall also include back pump out vanes to reduce thepressure and entry of foreign materials into the mechanical seal area. In addition, a lip seal shall be locatedbehind the impeller hub to further reduce the entry of foreign materials into the seal area. Impellers shall be directconnected to the motor shaft with a slip fit, key driven, and secured with an impeller bolt. The design shall includea replaceable cast iron suction cover. The suction cover shall contain a groove(s) perpendicular to the suction openingto disrupt fibrous solids that may otherwise become lodged between the impeller and suction cover. The suctioncover shall be designed such that it may be adjusted to maintain working clearances and hydraulic efficiencies.
2. Mechanical Sealsa. For units 2 to 5 HP, double mechanical seals operating in an oil bath shall be provided on all units. The oil filled
seal chamber shall be designed to prevent over-filling and include an anti-vortexing vane to insure proper lubricationof both seal faces. Lower face materials shall be silicon carbide, upper faces carbon vs. ceramic, NBR elastomers,and 304SS hardware. Seal system shall not rely on pumping medium for lubrication.
b. Units 71/2 to 60 HP shall be designed to include a double mechanical seal in a tandem arrangement. Each sealshall be positively driven and act independently with its own spring system. The upper seal operates in an oilbath, while the lower seal is lubricated by the oil from between the shaft and the seal faces, and in contact with
EBARA Submersible Sewage Pumps DLFMU–Explosion Proof Non-clog
Specifications
Project: Model: Chk’d: Date:
EBARA Fluid Handlingwww.pumpsebara.com 2-164(t) 803 327 5005 • (f) 803 327 5097 rev. 04/11
the pumpage. The oil filled seal chamber shall be designed to prevent over-filling and include an anti-vortexing vane to insure proper lubrication of both seal faces. Lower face materials shall be silicon carbide (tungsten carbidefor 150-300 DLFU 50 & 60 HP only), upper faces carbon vs. ceramic, NBR elastomers, and 304SS hardware. Seal system shall not rely on pumping medium for lubrication.
E. Motor Construction:
The pump motor shall be FM Explosion Proof, Class 1, Division 1, Groups C, D. The design shall be an air filled induction type with a squirrel cage rotor, shell type design, built to NEMA MG-1, Design B specifications. Stator windings shall be copper, insulated with moisture resistant Class H insulation (Class F for 2-5HP). The stator shall be dipped and baked three times in Class H varnish (Class F for 2-5HP) and heat shrunk fitted into the stator housing. Rotor bars and short circuit rings shall be manufactured of cast aluminum. Motor shaft shall be one piece AISI403 material for 2 to 5 HP, AISI420 for 71/2 to 60 HP material, rotating on two permanently lubricated ball bearings designed for a minimum B-10 life of 60,000 hours. Motor service factor shall be 1.15 and capable of up to 20 starts per hour. The motor shall be designed for continuous duty pumping at a maximum sump temperature of 104°F. Voltage and frequency tolerances shall be a maximum 10 / 5% respectively. Motor over temperature protection shall be provided by miniature thermal protectors embedded in the windings. Mechanical seal failure protection shall be provided by a mechanical float switch located in a chamber above the seal. This switch shall be comprised of a magnetic float that actuates a dry reed switch encapsulated within the stem. Should the mechanical seal fail, liquid shall be directed into the float chamber, in which the rising liquid activates the switch opening the normally closed circuit. For units 2 to 10 HP the float body and float shall be a polypropylene material with a 316SS stopper. Units 15 HP and greater, the float switch components shall be 304SS. The motor shall be non-overloading over the entire specified range of operation and be able to operate at full load intermittently while unsubmerged without damage to the unit.
Power cable jacket shall be manufactured of an oil resistant chloroprene rubber material, designed for submerged applications. Cable shall be watertight to a depth of a least 65'. The cable entry system shall comprise of primary, secondary, and tertiary sealing methods. The primary seal shall be achieved by a cylindrical elastomeric grommet compressed between the motor cover and a 304SS washer. Secondary sealing is accomplished with a compressed o-ring made of NBR material. Compression and subsequent sealing shall preclude specific torque requirements. Thesystem shall also include tertiary sealing to prevent leakage into the motor housing due to capillary action through the insulation if the cable is damaged or cut. The cable wires shall be cut, stripped, re-connected with a copper butt end connector, and embedded in epoxy within the cable gland. This provides a dead end for leakage through the cableinsulation into the motor junction area. The cable entry system shall be the same for both the power and control cables.
F. Guide Rail system:Design shall include two (2) 304SS schedule 40 guide rails sized to mount directly to the quick discharge connector,QDC, at the floor of the wetwell and to a guide rail bracket at the top of the wetwell below the hatch opening, (refer to project drawings). Intermediate guide brackets are recommended for rail lengths over 15 feet.
Guide rails are not part of the pump package and shall be supplied by others.
The QDC shall be manufactured of cast iron, ASTM A48 Class 30. It shall be designed to adequately support the guide rails, discharge piping, and pumping unit under both static and dynamic loading conditions with support legs that are suitable for anchoring it to the wetwell floor. The face of the inlet QDC flange shall be perpendicular to the floor of the wetwell. The discharge flange of the QDC shall conform to ANSI B16.1 Class 125.
The pump design shall include an integral self-aligning sliding bracket. Sealing of the pumping unit to the QDC shall be accomplished by a single, linear, downward motion of the pump. The entire weight of the pump unit shall be guidedto and wedged tightly against the inlet flange of the QDC, making metal to metal contact with the pump discharge forming a seal without the use of bolts, gaskets or o-rings.
A stainless steel lifting chain of adequate length for removing and installing the pump unit is recommended. The chain shall have a round link with a 2-1/4'' inside diameter every two feet. This link will allow for a sliding pinch bar through the link to pick the chain, more than once if necessary, at multiple intervals during pump removal and installation.
EBARA Submersible Sewage Pumps DLFU
Selection Chart
Project: Model: Chk’d: Date:Model DLFUThree Phase 60Hz
60Hz (Synchronous Speed – 1800 RPM)
1
8
2
17 / 18
19 / 20
11 / 12
4
5
3
67
1010
15
20
30
40
5060
80
80
6050
40
30
20
15
10
8
65
4
3
100
150
200
300m ft
15 20 30 40 50 60 80 100 150 200 300 400 8001000 1500 2000 3000 4000 USGPM500 600
0.20.1 0.3 0.4 0.5 0.6 0.8 1.0 1.5 2.0 3.0 4.0 5.0 6.0 8.0 10 15 m3/min
CAPACITY
TOTA
L H
EAD
1 50DLFU61.5 2HP
2 80DLMFU61.5 2HP
3 80DLMFU62.2 3HP
4 80DLMFU63.7 5HP
5 80DLMFU65.5 7½HP
6 80DLCMFU67.5 10HP
7 80DLCMFU611 15HP
8 100DLFU61.5 2HP
9 80DLFU61.5 2HP
10 100DLMFU61.5 2HP
11 80DLFU62.2 3HP
12 100DLMFU62.2 3HP
13 80DLFU63.7 5HP
14 100DLMFU63.7 5HP
15 80DLFU65.5 7½HP
16 100DLMFU65.5 7½HP
17 80DLFU67.5 10HP
18 100DLMFU67.5 10HP
19 80DLFU611 15HP
20 100DLMFU611 15HP
21 80DLFU615 20HP
22 100DLMFU615 20HP
23 80DLFU618 25HP
24 100DLMFU618 25HP
25 80DLFU622 30HP
26 100DLMFU622 30HP
27 100DLFU630 40HP
28 100DLFU637 50HP
29 100DLFU645 60HP
30 100DLFU62.2 3HP
31 100DLFU63.7 5HP
32 100DLFU65.5 7½HP
33 100DLFU67.5 10HP
34 100DLFU611 15HP
35 100DLFU615 20HP
36 100DLFU618 25HP
37 100DLFU622 30HP
38 150DLFU630 40HP
39 150DLFU637 50HP
40 150DLFU645 60HP
41 150DLFU67.5 10HP
42 150DLFU611 15HP
43 150DLFU615 20HP
44 150DLFU618 25HP
45 150DLFU622 30HP
46 200DLFU630 40HP
47 200DLFU637 50HP
48 200DLFU645 60HP
49 200DLFU67.5 10HP
50 200DLFU611 15HP
51 200DLFU615 20HP
52 200DLFU618 25HP
53 200DLFU622 30HP
54 250DLFU611 15HP
55 250DLBFU615 20HP
56 250DLCFU615 20HP
57 250DLFU618 25HP
58 250DLFU622 30HP
59 250DLFU630 40HP
60 250DLFU637 50HP
61 250DLFU645 60HP
62 300DLFU618 25HP
63 300DLFU622 30HP
64 300DLFU630 40HP
65 300DLFU637 50HP
66 300DLFU645 60HP
13 / 14
15 / 16
30
3132
33
34
35
41
49
50
54
42
43
51
59
6263
64
65
66
60
4636
44 45
52
55
58
61
56
57
53
4748
3738
39
40
Please note: Overlap in coverage is designated by the two numbers; for example "9 / 10". Refer to the legend below for the specific model numbers.
9 / 10
21 / 22
23 / 2425 / 26
2728 29
EBARA Fluid Handlingwww.pumpsebara.com 2-165(t) 803 327 5005 • (f) 803 327 5097 rev. 03/03
EBARA Submersible Sewage Pumps DLFU
Performance Curves
Project: GPM: TDH: EFF: HP: Chk’d: Date:
0 20 40 60 80 100 120 140
Capacity USGPM
0
10
20
30
40
50
60To
tal H
ead
(Ft)
0
10
20
30
40
50
60
Effi
cien
cy (
%)
0
1
2
Bra
ke H
orse
pow
er (
BH
P)
Max. Dia. 182mm-No Trim
BHP
EFFICIENCY
Curve No: DL-C603-9203Solid Dia 1 1/2" LM65
0 20 40 60 80 100 120 140 160 180 200 220 240 260
Capacity USGPM
0
10
20
30
40
50
Tota
l Hea
d (F
t)
0
10
20
30
40
50
60
70
80
90
100
Effi
cien
cy (
%)
0.0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
4.0
4.5
5.0
5.5
6.0
Bra
ke H
orse
pow
er (
BH
P)
Max. Dia. 170mm - No Trim
BHP
EFFICIENCY
Curve No: DL-C604-9203Solid Dia: 2 1/2" LM80
50DLF61.5 (2HP) Synchronous Speed: 1800 RPM 2, 3 inch Discharge
80DLF61.5 (2HP) Synchronous Speed: 1800 RPM 3, 4 inch Discharge
EBARA Fluid Handlingwww.pumpsebara.com 2-166(t) 803 327 5005 • (f) 803 327 5097 rev. 01/02
EBARA Submersible Sewage Pumps DLFU
Performance Curves
Project: GPM: TDH: EFF: HP: Chk’d: Date:
0 20 40 60 80 100 120 140 160 180 200 220 240 260
Capacity USGPM
0
10
20
30
40
50To
tal H
ead
(Ft)
0
10
20
30
40
50
60
Effi
cien
cy (
%)
0
1
2
Bra
ke H
orse
pow
er (
BH
P)
Max. Dia. 170mm-No Trim
BHP
EFFICIENCY
Curve No: DLM-C601-9203Solid Dia 3" LM80
0 40 80 120 160 200 240 280 320 360 400Capacity USGPM
0
10
20
30
40
Tota
l Hea
d (F
t)
0
10
20
30
40
50
60
70
Effi
cien
cy (
%)
0
1
2
3
Bra
ke H
orse
pow
er (
BH
P)
Max. Dia. 160mm
BHP
EFFICIENCY
Curve No: DL-C605-9203Solid Dia 2 1/2" LL100
Min. Dia. 145mm
80DLMF61.5 (2HP) Synchronous Speed: 1800 RPM 3, 4 inch Discharge
80DLF62.2 (3HP) Synchronous Speed: 1800 RPM 3, 4 inch Discharge
EBARA Fluid Handlingwww.pumpsebara.com 2-167(t) 803 327 5005 • (f) 803 327 5097 rev. 01/02
EBARA Submersible Sewage Pumps DLFU
Performance Curves
Project: GPM: TDH: EFF: HP: Chk’d: Date:
0 20 40 60 80 100 120 140 160 180 200 220 240 260
Capacity USGPM
0
10
20
30
40
50
60To
tal H
ead
(Ft)
0
10
20
30
40
50
Effi
cien
cy (
%)
0
1
2
3
Bra
ke H
orse
pow
er (
BH
P)
Max. Dia. 188mm - No Trim
BHP
EFFICIENCY
Curve No: DLM-C602-9203Solid Dia 3" LM80
0 100 200 300 400 500 600
Capacity USGPM
0
10
20
30
40
50
60
Tota
l Hea
d (F
t)
0
10
20
30
40
50
60
70
EF
FIC
IEN
CY
(%
)
0
5
Bra
ke H
orse
pow
er (
BH
P)
Max. Dia. 189mm
BHP
EFFICIENCY
Curve No: DLM-C607-9203
Solid Dia 3" LL100
Min. Dia. 171mm
80DLMF62.2 (3HP) Synchronous Speed: 1800 RPM 3, 4 inch Discharge
80DLF63.7 (5HP) Synchronous Speed: 1800 RPM 3, 4 inch Discharge
EBARA Fluid Handlingwww.pumpsebara.com 2-168(t) 803 327 5005 • (f) 803 327 5097 rev. 01/02
EBARA Submersible Sewage Pumps DLFU
Performance Curves
Project: GPM: TDH: EFF: HP: Chk’d: Date:
0 40 80 120 160 200 240 280 320
Capacity USGPM
0
10
20
30
40
50
60
70To
tal H
ead
(Ft)
0
10
20
30
40
50
60
70
Effi
cien
cy (
%)
0
5
Bra
ke H
orse
pow
er (
BH
P)
Max. Dia. 208mm
BHP
EFFICIENCY
Curve No: DLM-C603-9203Solid Dia 3" LM80
Min. Dia. 188mm
0 100 200 300 400 500 600
Capacity USGPM
0
10
20
30
40
50
60
70
Tota
l Hea
d (F
t)
0
10
20
30
40
50
60
EF
FIC
IEN
CY
(%
)
0
2
4
6
8
Bra
ke H
orse
pow
er (
BH
P)
Max. Dia. 207mm
EFFICIENCY
Curve No: DLM-C608-9203Solid Dia 3" LL100
Min. Dia. 186mm
BHP
80DLMF63.7 (5HP) Synchronous Speed: 1800 RPM 3, 4 inch Discharge
80DLF65.5 (71/2HP) Synchronous Speed: 1800 RPM 3, 4 inch Discharge
EBARA Fluid Handlingwww.pumpsebara.com 2-169(t) 803 327 5005 • (f) 803 327 5097 rev. 01/02
EBARA Submersible Sewage Pumps DLFU
Performance Curves
Project: GPM: TDH: EFF: HP: Chk’d: Date:
0 50 100 150 200 250 300 350 400
Capacity USGPM
0
10
20
30
40
50
60
70
80
90To
tal H
ead
(Ft)
0
10
20
30
40
50
60
Effi
cien
cy (
%)
0
2
4
6
8
Bra
ke H
orse
pow
er (
BH
P)
Max. Dia. 225mm
BHP
EFFICIENCY
Curve No: DLM-C604-9203Solid Dia: 3" LM80
Min. Dia. 203mm
0 100 200 300 400 500 600 700 800
Capacity USGPM
0
10
20
30
40
50
60
70
80
Tota
l Hea
d (F
t)
0
10
20
30
40
50
60
70
EF
FIC
IEN
CY
(%
)
0
5
10
Bra
ke H
orse
pow
er (
BH
P)
Max. Dia. 151.9/249mm
EFFICIENCY
Curve No: DLM-C609-9203Solid Dia 3" LL100
Min. Dia. 122.9/220mm
BHP
80DLMF65.5 (71/2HP) Synchronous Speed: 1800 RPM 3, 4 inch Discharge
80DLF67.5 (10HP) Synchronous Speed: 1800 RPM 3, 4 inch Discharge
EBARA Fluid Handlingwww.pumpsebara.com 2-170(t) 803 327 5005 • (f) 803 327 5097 rev. 02/09
EBARA Submersible Sewage Pumps DLFU
Performance Curves
Project: GPM: TDH: EFF: HP: Chk’d: Date:
0 100 200 300 400 500 600
Capacity USGPM
0
10
20
30
40
50
60
70
80
90
100To
tal H
ead
(Ft)
0
10
20
30
40
50
60
70
80
90
100
Effi
cien
cy (
%)
0
5
10
15
20
25
30
35
40
45
50
Max. Dia. 187.5/259mm T.D.H.
BHP
EFFICIENCY
Min. Dia. 165.5/237mm T.D.H.
Curve No: DLM-C605-9203Solid Dia: 3" LL80
Bra
ke H
orse
pow
er (
BH
P)
0 100 200 300 400 500 600 700 800
Capacity USGPM
0
10
20
30
40
50
60
70
80
90
Tota
l Hea
d (F
t)
0
10
20
30
40
50
60
70
80
90
100
Effi
cien
cy(%
)
0
5
10
15
Bra
ke H
orse
pow
er (
BH
P)
Max. Dia. 172.4/263mm
EFFICIENCY
Curve No: DLM-C610-9203Solid Dia 3" LL100
Min. Dia. 151.4/242mm
BHP
80DLCMF67.5 (10HP) Synchronous Speed: 1800 RPM 3, 4 inch Discharge
80DLF611 (15HP) Synchronous Speed: 1800 RPM 3, 4 inch Discharge
EBARA Fluid Handlingwww.pumpsebara.com 2-171(t) 803 327 5005 • (f) 803 327 5097 rev. 01/02
EBARA Submersible Sewage Pumps DLFU
Performance Curves
Project: GPM: TDH: EFF: HP: Chk’d: Date:
0 100 200 300 400 500 600
Capacity USGPM
0
10
20
30
40
50
60
70
80
90
100
110
120To
tal H
ead
(Ft)
0
10
20
30
40
50
60
70
80
90
100
Effi
cien
cy (
%)
0
5
10
15
Bra
ke H
orse
pow
er (
BH
P)
Max. Dia. 215/281mm
BHP
EFFICIENCY
Curve No: DLM-C606-9203Solid Dia 3" LL80
Min. Dia. 191/257mm
0 100 200 300 400 500 600 700 800
Capacity USGPM
0
10
20
30
40
50
60
70
80
90
100
110
120
Tota
l Hea
d (F
t)
0
10
20
30
40
50
60
70
Effi
cien
cy (
%)
05101520
Bra
ke H
orse
pow
er (
BH
P)
Max. Dia. 196.4/287mm
BHP
EFFICIENCY
Curve No: DLM-C611-9203Solid Dia 3" LL100
Min. Dia. 172.4/263mm
80DLCMF611 (15HP) Synchronous Speed: 1800 RPM 3, 4 inch Discharge
80DLF615 (20HP) Synchronous Speed: 1800 RPM 3, 4 inch Discharge
EBARA Fluid Handlingwww.pumpsebara.com 2-172(t) 803 327 5005 • (f) 803 327 5097 rev. 01/02
EBARA Submersible Sewage Pumps DLFU
Performance Curves
Project: GPM: TDH: EFF: HP: Chk’d: Date:
0 100 200 300 400 500 600 700 800
Capacity USGPM
0
20
40
60
80
100
120
140To
tal H
ead
(Ft)
0
10
20
30
40
50
60
70
Effi
cien
cy (
%)
0
5
10
15
20
25
Bra
ke H
orse
pow
er (
BH
P)
Max. Dia. 225/307mm
BHP
EFFICIENCY
Curve No: DLM-C612-9203Solid Dia 3" LL100
Min. Dia. 199/281mm
0 100 200 300 400 500 600 700 800
Capacity USGPM
0
20
40
60
80
100
120
140
160
Tota
l Hea
d (F
t)
0
10
20
30
40
50
60
70Effi
cien
cy (
%)
0
10
20
30
Bra
ke H
orse
pow
er (
BH
P)
Max. Dia. 238/320mm
BHP
EFFICIENCY
Curve No: DLM-C613-9203Solid Dia 3" LL100
Min. Dia. 211/293mm
80DLF618 (25HP) Synchronous Speed: 1800 RPM 3, 4 inch Discharge
80DLF622 (30HP) Synchronous Speed: 1800 RPM 3, 4 inch Discharge
EBARA Fluid Handlingwww.pumpsebara.com 2-173(t) 803 327 5005 • (f) 803 327 5097 rev. 01/02
EBARA Submersible Sewage Pumps DLFU
Performance Curves
Project: GPM: TDH: EFF: HP: Chk’d: Date:
0 50 100 150 200 250 300 350
Capacity USGPM
0
10
20
30To
tal H
ead
(Ft)
0
10
20
30
40
50
60
Effi
cien
cy (
%)
0
1
2
3
Bra
ke H
orse
pow
er (
BH
P)
Max. Dia. 138mm
BHP
EFFICIENCY
Curve No: DL-C613-9203Solid Dia 3" LM80
Min. Dia. 125mm
0 100 200 300 400
Capacity USGPM
0
10
20
30
40
Tota
l Hea
d (F
t)
0
10
20
30
40
50
60
Effi
cien
cy (
%)
0
1
2
3
Bra
ke H
orse
pow
er (
BH
P)
Max. Dia. 160mm
BHP
EFFICIENCY
Curve No: DL-C614-9203Solid Dia 3" LM80
Min. Dia. 145mm
100DLF61.5 (2HP) Synchronous Speed: 1800 RPM 3, 4 inch Discharge
100DLF62.2 (3HP) Synchronous Speed: 1800 RPM 3, 4 inch Discharge
EBARA Fluid Handlingwww.pumpsebara.com 2-174(t) 803 327 5005 • (f) 803 327 5097 rev. 01/02
EBARA Submersible Sewage Pumps DLFU
Performance Curves
Project: GPM: TDH: EFF: HP: Chk’d: Date:
0 40 80 120 160 200 240 280 320 360 400Capacity USGPM
0
10
20
30
40To
tal H
ead
(Ft)
0
10
20
30
40
50
60
70
Effi
cien
cy (
%)
0
1
2
3
Bra
ke H
orse
pow
er (
BH
P)
Max. Dia. 160mm
BHP
EFFICIENCY
Curve No: DL-C605-9203Solid Dia 2 1/2" LL100
Min. Dia. 145mm
0 50 100 150 200 250 300 350 400 450 500 550 600
Capacity USGPM
0
10
20
30
40
50
Tota
l Hea
d (F
t)
0
10
20
30
40
50
60
Effi
cien
cy (
%)
012345
Bra
ke H
orse
pow
er (
BH
P)
Max. Dia. 172mm
BHP
EFFICIENCY
Curve No: DL-C615-9203Solid Dia 3" LM80
Min. Dia. 156mm
100DLMF62.2 (3HP) Synchronous Speed: 1800 RPM 3, 4 inch Discharge
100DLF63.7 (5HP) Synchronous Speed: 1800 RPM 3, 4 inch Discharge
EBARA Fluid Handlingwww.pumpsebara.com 2-175(t) 803 327 5005 • (f) 803 327 5097 rev. 01/02
EBARA Submersible Sewage Pumps DLFU
Performance Curves
Project: GPM: TDH: EFF: HP: Chk’d: Date:
0 100 200 300 400 500 600
Capacity USGPM
0
10
20
30
40
50
60To
tal H
ead
(Ft)
0
10
20
30
40
50
60
70
Effi
cien
cy (
%)
0
5
Bra
ke H
orse
pow
er (
BH
P)
Max. Dia. 189mm
BHP
EFFICIENCY
Curve No: DLM-C607-9203Solid Dia 3" LL100
Min. Dia. 171mm
0 100 200 300 400 500 600 700 800 900 1000
Capacity USGPM
0
5
10
15
20
25
30
35
40
45
Tota
l Hea
d (F
t)
0
10
20
30
40
50
60
70
80
90
100
Effi
cien
cy (
%)
0
5
10
Bra
ke H
orse
pow
er (
BH
P)
Max. Dia. 102.8/217mm
BHP
EFFICIENCY
Curve No: DLM-C614-9203Solid Dia 3" LL125
Min. Dia. 89.8/204mm
100DLMF63.7 (5HP) Synchronous Speed: 1800 RPM 3, 4 inch Discharge
100DLF65.5 (71/2HP) Synchronous Speed: 1800 RPM 4, 6 inch Discharge
EBARA Fluid Handlingwww.pumpsebara.com 2-176(t) 803 327 5005 • (f) 803 327 5097 rev. 03/07
EBARA Submersible Sewage Pumps DLFU
Performance Curves
Project: GPM: TDH: EFF: HP: Chk’d: Date:
0 100 200 300 400 500 600
Capacity USGPM
0
10
20
30
40
50
60
70To
tal H
ead
(Ft)
0
10
20
30
40
50
60
Effi
cien
cy (
%)
0
2
4
6
8
Bra
ke H
orse
pow
er (
BH
P)
Max. Dia. 207mm
EFFICIENCY
Curve No: DLM-C608-9203Solid Dia 3" LL100
Min. Dia. 186mm
BHP
0 100 200 300 400 500 600 700 800 900 1000 1100
Capacity USGPM
0
10
20
30
40
50
60
Tota
l Hea
d (F
t)
0
10
20
30
40
50
60
70
80
90
100
Effi
cien
cy (
%)
0
5
10
Bra
ke H
orse
pow
er (
BH
P)
Max. Dia. 120.8/235mm
BHP
EFFICIENCY
Curve No: DLM-C615-9203Solid Dia 3" LL125
Min. Dia. 103.8/218mm
100DLMF65.5 (71/2HP) Synchronous Speed: 1800 RPM 3, 4 inch Discharge
100DLF67.5 (10HP) Synchronous Speed: 1800 RPM 4, 6 inch Discharge
EBARA Fluid Handlingwww.pumpsebara.com 2-176.1(t) 803 327 5005 • (f) 803 327 5097 rev. 01/02
EBARA Submersible Sewage Pumps DLFU
Performance Curves
Project: GPM: TDH: EFF: HP: Chk’d: Date:
0 100 200 300 400 500 600 700 800
Capacity USGPM
0
10
20
30
40
50
60
70
80
Tota
l Hea
d (F
t)
0
10
20
30
40
50
60
70
80
90
100
Effic
iency
(%)
0
10
20
30
40
50
60
70
80
90
Brak
e Ho
rsep
ower
(BHP
)
Max. Dia. 151.9/249mm.
Min. Dia. 122.9/220mm
BHP
EFFICIENCY
Curve No: DLM-C609-9203Solid Dia. 3"LL100
0 100 200 300 400 500 600 700 800 900 1000 1100
Capacity USGPM
0
10
20
30
40
50
60
70
80
90
Tota
l Hea
d (F
t)
0
10
20
30
40
50
60
70
Effic
iency
(%)
051015
Brak
e Ho
rsep
ower
(BHP
)
Max. Dia. 142.8/257mm
BHP
EFFICIENCY
Curve No: DLM-C616-9203Solid Dia 3"LL125
Min. Dia. 120.7/235mm
100DLMF67.5 (10HP) Synchronous Speed: 1800 RPM 3, 4 inch Discharge
100DLF611 (15HP) Synchronous Speed: 1800 RPM 4, 6 inch Discharge
EBARA Fluid Handlingwww.pumpsebara.com 2-177(t) 803 327 5005 • (f) 803 327 5097 rev. 02/15
EBARA Submersible Sewage Pumps DLFU
Performance Curves
Project: GPM: TDH: EFF: HP: Chk’d: Date:
0 100 200 300 400 500 600 700 800
Capacity USGPM
0
10
20
30
40
50
60
70
80
90To
tal H
ead
(Ft)
0
10
20
30
40
50
60
70
80
90
100
Effi
cien
cy (
%)
0
10
20
30
40
50
60
70
80
90
Max. Dia. 172.4/263mm
Min. Dia. 151.4/242mm
BHP
EFFICIENCY
Bra
ke H
orse
pow
er (
BH
P)
Curve No: DLM-C610-9203 Solid Dia 3" LL100
0 200 400 600 800 1000 1200
Capacity USGPM
0
10
20
30
40
50
60
70
80
90
100
110
Tota
l Hea
d (F
t)
0
10
20
30
40
50
60
70
Effi
cien
cy (
%)
05101520
Bra
ke H
orse
pow
er (
BH
P)
Max. Dia. 173.1/278mm
BHP
EFFICIENCY
Curve No: DLM-C617-9203Solid Dia 3" LL125
Min. Dia. 151.1/256mm
100DLMF611 (15HP) Synchronous Speed: 1800 RPM 3, 4 inch Discharge
100DLF615 (20HP) Synchronous Speed: 1800 RPM 4, 6 inch Discharge
EBARA Fluid Handlingwww.pumpsebara.com 2-178(t) 803 327 5005 • (f) 803 327 5097 rev. 01/02
EBARA Submersible Sewage Pumps DLFU
Performance Curves
Project: GPM: TDH: EFF: HP: Chk’d: Date:
0 100 200 300 400 500 600 700 800
Capacity USGPM
0
10
20
30
40
50
60
70
80
90
100
110
120To
tal H
ead
(Ft)
0
10
20
30
40
50
60
70
Effi
cien
cy (
%)
05101520
Bra
ke H
orse
pow
er (
BH
P)
Max. Dia. 196.4/287mm
BHP
EFFICIENCY
Curve No: DLM-C611-9203Solid Dia 3" LL100
Min. Dia. 172.4/263mm
0 100 200 300 400 500 600 700 800
Capacity USGPM
0
20
40
60
80
100
120
140
Tota
l Hea
d (F
t)
0
10
20
30
40
50
60
70
Effi
cien
cy (
%)
0
5
10
15
20
25
Bra
ke H
orse
pow
er (
BH
P)
Max. Dia. 225/307mm
BHP
EFFICIENCY
Curve No: DLM-C612-9203Solid Dia 3" LL100
Min. Dia. 199/281mm
100DLMF615 (20HP) Synchronous Speed: 1800 RPM 3, 4 inch Discharge
100DLMF618 (25HP) Synchronous Speed: 1800 RPM 3, 4 inch Discharge
EBARA Fluid Handlingwww.pumpsebara.com 2-179(t) 803 327 5005 • (f) 803 327 5097 rev. 01/02
EBARA Submersible Sewage Pumps DLFU
Performance Curves
Project: GPM: TDH: EFF: HP: Chk’d: Date:
0 100 200 300 400 500 600 700 800 900 1000 1100 1200
Capacity USGPM
0
10
20
30
40
50
60
70
80
90
100
110
120To
tal H
ead
(Ft)
0
10
20
30
40
50
60
70
80
90
100
Effi
cien
cy (
%)
0510152025
Bra
ke H
orse
pow
er (
BH
P)
Max. Dia. 192/288mm
Min. Dia. 168/264mm
BHP
EFFICIENCY
Curve No: DLM-C618-9203Solid Dia 3" LL125
0 100 200 300 400 500 600 700 800
Capacity USGPM
0
20
40
60
80
100
120
140
160
Tota
l Hea
d (F
t)
0
10
20
30
40
50
60
70Effi
cien
cy (
%)
0
10
20
30
Bra
ke H
orse
pow
er (
BH
P)
Max. Dia. 238/320mm
BHP
EFFICIENCY
Curve No: DLM-C613-9203Solid Dia 3" LL100
Min. Dia. 211/293mm
100DLF618 (25HP) Synchronous Speed: 1800 RPM 4, 6 inch Discharge
100DLMF622 (30HP) Synchronous Speed: 1800 RPM 3, 4 inch Discharge
EBARA Fluid Handlingwww.pumpsebara.com 2-180(t) 803 327 5005 • (f) 803 327 5097 rev. 01/02
EBARA Submersible Sewage Pumps DLFU
Performance Curves
Project: GPM: TDH: EFF: HP: Chk’d: Date:
0 100 200 300 400 500 600 700 800 900 1000 1100 1200
Capacity USGPM
0
20
40
60
80
100
120
140To
tal H
ead
(Ft)
0
10
20
30
40
50
60
70
80
90
100
Effi
cien
cy (
%)
0
10
20
30
Bra
ke H
orse
pow
er (
BH
P)
Max. Dia. 208/304mm
Min. Dia. 183/279mm
BHP
EFFICIENCY
Curve No: DLM-C619-9203Solid Dia 3" LL125
0 200 400 600 800 1000 1200 1400 1600 1800
Capacity USGPM
40
60
80
100
120
140
160
180
200
220
240
260
Tota
l Hea
d (F
t)
D = 360mmCurve No: DL-C601-9608Solid Dia 3" LL100
D = 330mm
D = 315mm
40 HP
60 HP
D = 345mm
D = 300mm
50 HP
50
6065
68
70
70
100DLF622 (30HP) Synchronous Speed: 1800 RPM 4, 6 inch Discharge
100DLF630 to 645 (40-60HP) Synchronous Speed: 1800 RPM 3, 4 inch Discharge
EBARA Fluid Handlingwww.pumpsebara.com 2-180.1(t) 803 327 5005 • (f) 803 327 5097 rev. 01/02
EBARA Submersible Sewage Pumps DLFU
Performance Curves
Project: GPM: TDH: EFF: HP: Chk’d: Date:
0 200 400 600 800 1000 1200 1400
Capacity USGPM
0
10
20
30
40
50
60To
tal H
ead
(Ft)
0
10
20
30
40
50
60
70
Effi
cien
cy (
%)
0
5
10
Bra
ke H
orse
pow
er (
BH
P)
Max. Dia. 124.6/225mm
BHP
EFFICIENCY
Curve No: DL-C622-9203Solid Dia 3" LL150
Min. Dia. 107.6/208mm
0 200 400 600 800 1000 1200 1400 1600
Capacity USGPM
0
10
20
30
40
50
60
70
80
Tota
l Hea
d (F
t)
0
10
20
30
40
50
60
70
Effi
cien
cy (
%)
0
5
10
15
Bra
ke H
orse
pow
er (
BH
P)
Max. Dia. 143.6/244mm
BHP
EFFICIENCY
Curve No: DL-C623-9203Solid Dia 3" LL150
Min. Dia. 125.6/226mm
150DLF67.5 200DLF67.5 (10HP) Synchronous Speed: 1800 RPM 6, 8 inch Discharge
150DLF611 200DLF611 (15HP) Synchronous Speed: 1800 RPM 6, 8 inch Discharge
EBARA Fluid Handlingwww.pumpsebara.com 2-181(t) 803 327 5005 • (f) 803 327 5097 rev. 01/02
EBARA Submersible Sewage Pumps DLFU
Performance Curves
Project: GPM: TDH: EFF: HP: Chk’d: Date:
0 200 400 600 800 1000 1200 1400 1600
Capacity USGPM
0
10
20
30
40
50
60
70
80
90
100To
tal H
ead
(Ft)
0
10
20
30
40
50
60
70
Effi
cien
cy (
%)
0
10
20
Bra
ke H
orse
pow
er (
BH
P)
Max. Dia. 180/268mm
BHP
EFFICIENCY
Curve No: DL-C624-9203Solid Dia 3" LL150
Min. Dia. 152/240mm
0 200 400 600 800 1000 1200 1400 1600
Capacity USGPM
0
10
20
30
40
50
60
70
80
90
100
110
Tota
l Hea
d (F
t)
0
10
20
30
40
50
60
70
Effi
cien
cy (
%)
0510152025
Bra
ke H
orse
pow
er (
BH
P)
Max. Dia. 186/274mm
BHP
EFFICIENCY
Curve No: DL-C625-9203Solid Dia 3" LL150
Min. Dia. 163/251mm
150DLF615 200DLF615 (20HP) Synchronous Speed: 1800 RPM 6, 8 inch Discharge
150DLF618 200DLF618 (25HP) Synchronous Speed: 1800 RPM 6, 8 inch Discharge
EBARA Fluid Handlingwww.pumpsebara.com 2-181.1(t) 803 327 5005 • (f) 803 327 5097 rev. 01/02
EBARA Submersible Sewage Pumps DLFU
Performance Curves
Project: GPM: TDH: EFF: HP: Chk’d: Date:
0 200 400 600 800 1000 1200 1400 1600
Capacity USGPM
0
10
20
30
40
50
60
70
80
90
100
110To
tal H
ead
(Ft)
0
10
20
30
40
50
60
70
Effi
cien
cy (
%)
0
10
20
30
Bra
ke H
orse
pow
er (
BH
P)
Max. Dia. 192/296mm
BHP
EFFICIENCY
Curve No: DL-C626-9203Solid Dia 3" LL150
Min. Dia. 168/272mm
0 200 400 600 800 1000 1200 1400 1600 1800 2000
Capacity USGPM
0
20
40
60
80
100
120
140
Tota
l Hea
d (F
t)
0
10
20
30
40
50
60
70
80
Effic
iency
(%)
0
10
20
30
40
Brak
e Ho
rsep
ower
(BHP
)
Max. Dia. 204/310mm
BHP
EFFICIENCY
Curve No: DLY-C601-9203Solid Dia 3" LL150Y
Min. Dia. 178/284mm
150DLF622 200DLF622 (30HP) Synchronous Speed: 1800 RPM 6,8 inch Discharge
150DLF630 (40HP) Synchronous Speed: 1800 RPM 6 inch Discharge
EBARA Fluid Handlingwww.pumpsebara.com 2-182(t) 803 327 5005 • (f) 803 327 5097 rev. 02/15
EBARA Submersible Sewage Pumps DLFU
Performance Curves
Project: GPM: TDH: EFF: HP: Chk’d: Date:
0 200 400 600 800 1000 1200 1400 1600 1800 2000
Capacity USGPM
0
20
40
60
80
100
120
140
160To
tal H
ead
(Ft)
0
10
20
30
40
50
60
70
Effi
cien
cy (
%)
0
10
20
30
40
50
Bra
ke H
orse
pow
er (
BH
P)
BHP
EFFICIENCY
Curve No: DLY-C602-9203Solid Dia 3" LL150Y
Min. Dia. 199/297mm
Max. Dia. 226/324mm
0 200 400 600 800 1000 1200 1400 1600 1800
Capacity USGPM
0
20
40
60
80
100
120
140
160
180
200
Tota
l Hea
d (F
t)
0
10
20
30
40
50
60
70
80
Effi
cien
cy (
%)
20
30
40
50
60
Bra
ke H
orse
pow
er (
BH
P)
Max. Dia. 255/353mm
BHP
Curve No: DLY-C603-9203Solid Dia 3" LL150Y
Min. Dia. 225/323mm
EFFICIENCY
150DLF637 (50HP) Synchronous Speed: 1800 RPM 6 inch Discharge
150DLF645 (60HP) Synchronous Speed: 1800 RPM 6 inch Discharge
EBARA Fluid Handlingwww.pumpsebara.com 2-183(t) 803 327 5005 • (f) 803 327 5097 rev. 01/02
EBARA Submersible Sewage Pumps DLFU
Performance Curves
Project: GPM: TDH: EFF: HP: Chk’d: Date:
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200
Capacity USGPM
0
10
20
30
40
50
60
70
80
90
100
110
120To
tal H
ead
(Ft)
0
10
20
30
40
50
60
70
Effi
cien
cy (
%)
010203040
Bra
ke H
orse
pow
er (
BH
P)
Max. Dia. 220/307mm
BHP
Curve No: DLY-C604-9203Solid Dia 3" LL200Y
Min. Dia. 194/281mm
EFFICIENCY
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200
Capacity USGPM
0
20
40
60
80
100
120
140
160
Tota
l Hea
d (F
t)
010203040506070Ef
ficien
cy (%
)
1020304050
Brak
e Ho
rsep
ower
(BHP
)
Max. Dia. 241/328mm
BHP
Curve No: DLY-C605-9203Solid Dia 3"LL200Y
Min. Dia. 217/304mm
EFFICIENCY
200DLF630 (40HP) Synchronous Speed: 1800 RPM 8 inch Discharge
200DLF637 (50HP) Synchronous Speed: 1800 RPM 8 inch Discharge
EBARA Fluid Handlingwww.pumpsebara.com 2-184(t) 803 327 5005 • (f) 803 327 5097 rev. 02/15
EBARA Submersible Sewage Pumps DLFU
Performance Curves
Project: GPM: TDH: EFF: HP: Chk’d: Date:
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400
Capacity USGPM
20
40
60
80
100
120
140
160
180To
tal H
ead
(Ft)
20
30
40
50
60
70
80
Effi
cien
cy (
%)
20
30
40
50
60
Bra
ke H
orse
pow
er (
BH
P)
Max. Dia. 263/350mm
BHP
Curve No: DLY-C606-9203Solid Dia 3" LL200Y
Min. Dia. 232/319mm
EFFICIENCY
0 200 400 600 800 1000 1200 1400 1600 1800 2000
Capacity USGPM
0
10
20
30
40
50
60
Tota
l Hea
d (F
t)
0
10
20
30
40
50
60
70
80
90
100
EF
FIC
IEN
CY
(%
)
0
5
10
15
Bra
ke H
orse
pow
er (
BH
P)
Max. Dia. 143.1/243mm
BHP
Curve No: DL-C627-9203Solid Dia 3 1/4" LL250
Min. Dia. 130.1/230mm
EFFICIENCY
200DLF645 (60HP) Synchronous Speed: 1800 RPM 8 inch Discharge
250DLF611 (15HP) Synchronous Speed: 1800 RPM 10 inch Discharge
EBARA Fluid Handlingwww.pumpsebara.com 2-185(t) 803 327 5005 • (f) 803 327 5097 rev. 03/07
EBARA Submersible Sewage Pumps DLFU
Performance Curves
Project: GPM: TDH: EFF: HP: Chk’d: Date:
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200
Capacity USGPM
0
10
20
30
40
50
60
70To
tal H
ead
(Ft)
0
10
20
30
40
50
60
70
EF
FIC
IEN
CY
(%
)
0
10
20
Bra
ke H
orse
pow
er (
BH
P)
Max. Dia. 158.1/258mm
BHP
Curve No: DL-C628-9203Solid Dia 3 1/4" LL250
Min. Dia. 138.1/238mm EFFICIENCY
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200
Capacity USGPM
0
10
20
30
40
50
60
70
80
Tota
l Hea
d (F
t)
010203040506070EF
FICI
ENCY
(%)
10152025
Brak
e Ho
rsep
ower
(BHP
) Max. Dia. 171/265mm
BHP
Curve No: DL-C629-9203Solid Dia 3 1/4"LL250
Min. Dia. 151/245mm
EFFICIENCY
250DLBF615 (20HP) Synchronous Speed: 1800 RPM 10 inch Discharge
250DLCF615 (20HP) Synchronous Speed: 1800 RPM 10 inch Discharge
EBARA Fluid Handlingwww.pumpsebara.com 2-186(t) 803 327 5005 • (f) 803 327 5097 rev. 02/15
EBARA Submersible Sewage Pumps DLFU
Performance Curves
Project: GPM: TDH: EFF: HP: Chk’d: Date:
0 400 800 1200 1600 2000 2400
Capacity USGPM
0
10
20
30
40
50
60
70
80
90To
tal H
ead
(Ft)
0
10
20
30
40
50
60
70
EF
FIC
IEN
CY
(%
)
0
5
10
15
20
25
Bra
ke H
orse
pow
er (
BH
P)
Max. Dia. 179/273mm
BHP
Curve No: DL-C630-9203Solid Dia 3 1/4" LL250
Min. Dia. 157/251mm
EFFICIENCY
0 400 800 1200 1600 2000 2400
Capacity USGPM
0
10
20
30
40
50
60
70
80
90
100
Tota
l Hea
d (F
t)
0
10
20
30
40
50
60
70
80
EFFI
CIEN
CY (%
)
0
10
20
30
Brak
e Ho
rsep
ower
(BHP
)
Max. Dia. 187/281mm
BHP
Curve No: DL-C631-9203Solid Dia 3 1/4" LL250
Min. Dia. 169/263mm
EFFICIENCY
250DLF618 (25HP) Synchronous Speed: 1800 RPM 10 inch Discharge
250DLF622 (30HP) Synchronous Speed: 1800 RPM 10 inch Discharge
EBARA Fluid Handlingwww.pumpsebara.com 2-187(t) 803 327 5005 • (f) 803 327 5097 rev. 02/15
EBARA Submersible Sewage Pumps DLFU
Performance Curves
Project: GPM: TDH: EFF: HP: Chk’d: Date:
0 300 600 900 1200 1500 1800 2100 2400 2700 3000
Capacity USGPM
0
10
20
30
40
50
60
70
80
90
100To
tal H
ead
(Ft)
0
10
20
30
40
50
60
70
80
EFFI
CIEN
CY (%
)
010203040
Brak
e Ho
rsep
ower
(BHP
)
Max. Dia. 216/306mm
BHP
Curve No: DLY-C607-9203Solid Dia 3"LL250Y
Min. Dia. 190/280mm
EFFICIENCY
0 500 1000 1500 2000 2500 3000
Capacity USGPM
0
20
40
60
80
100
120
140
Tota
l Hea
d (F
t)
0
10
20
30
40
50
60
70
EF
FIC
IEN
CY
(%
)
0
10
20
30
40
50
Bra
ke H
orse
pow
er (
BH
P)
Max. Dia. 231/321mm
BHP
Curve No: DLY-C608-9203Solid Dia 3" LL250Y
Min. Dia. 203/293mmEFFICIENCY
250DLF630 (40HP) Synchronous Speed: 1800 RPM 10 inch Discharge
250DLF637 (50HP) Synchronous Speed: 1800 RPM 10 inch Discharge
EBARA Fluid Handlingwww.pumpsebara.com 2-188(t) 803 327 5005 • (f) 803 327 5097 rev. 02/15
EBARA Submersible Sewage Pumps DLFU
Performance Curves
Project: GPM: TDH: EFF: HP: Chk’d: Date:
0 500 1000 1500 2000 2500 3000 3500
Capacity USGPM
0
20
40
60
80
100
120
140To
tal H
ead
(Ft)
0
10
20
30
40
50
60
70
80
EF
FIC
IEN
CY
(%
)
0
20
40
60
Bra
ke H
orse
pow
er (
BH
P)
Max. Dia. 248/338mm
BHP
Curve No: DLY-C609-9203Solid Dia 3" LL250Y
Min. Dia. 219/309mm
EFFICIENCY
0 1000 2000 3000Capacity USGPM
0
10
20
30
40
50
Tota
l Hea
d (F
t)
0
10
20
30
40
50
60
EF
FIC
IEN
CY
(%
)
0
5
10
15
20
25
Bra
ke H
orse
pow
er (
BH
P)
Max. Dia. 137.1/237mm
BHP
Curve No: DL-C632-9203Solid Dia 3 1/2" LL300
Min. Dia. 120.1/220mm
EFFICIENCY
250DLF645 (60HP) Synchronous Speed: 1800 RPM 10 inch Discharge
300DLF618 (25HP) Synchronous Speed: 1800 RPM 12 inch Discharge
EBARA Fluid Handlingwww.pumpsebara.com 2-189(t) 803 327 5005 • (f) 803 327 5097 rev. 01/02
EBARA Submersible Sewage Pumps DLFU
Performance Curves
Project: GPM: TDH: EFF: HP: Chk’d: Date:
0 1000 2000 3000
Capacity USGPM
0
10
20
30
40
50To
tal H
ead
(Ft)
0
10
20
30
40
50
60
Effi
cien
cy (
%)
10
20
30
Bra
ke H
orse
pow
er (
BH
P)
Max. Dia. 151.1/251mm
BHP
Curve No: DL-C633-9203Solid Dia 3 1/2" LL300
Min. Dia. 131.1/231mm EFFICIENCY
0 1000 2000 3000 4000
Capacity USGPM
0
10
20
30
40
50
60
Tota
l Hea
d (F
t)
0
10
20
30
40
50
60
70
Effi
cien
cy (
%)
10
20
30
40
Bra
ke H
orse
pow
er (
BH
P)
Max. Dia. 155.6/274mm
BHP
Curve No: DLY-C610-9203Solid Dia 3" LL300Y
Min. Dia. 134.6/253mm
EFFICIENCY
300DLF622 (30HP) Synchronous Speed: 1800 RPM 12 inch Discharge
300DLF630 (40HP) Synchronous Speed: 1800 RPM 12 inch Discharge
EBARA Fluid Handlingwww.pumpsebara.com 2-190(t) 803 327 5005 • (f) 803 327 5097 rev. 01/02
EBARA Submersible Sewage Pumps DLFU
Performance Curves
Project: GPM: TDH: EFF: HP: Chk’d: Date:
0 600 1200 1800 2400 3000 3600 4200
Capacity USGPM
0
10
20
30
40
50
60
70
80To
tal H
ead
(Ft)
0
10
20
30
40
50
60
70
80
EF
FIC
IEN
CY
(%
)
10
20
30
40
50
Bra
ke H
orse
pow
er (
BH
P)
Max. Dia. 174/278mm
BHP
Curve No: DLY-C611-9203Solid Dia 3" LL300Y
Min. Dia. 151/255mm
EFFICIENCY
0 1000 2000 3000 4000 5000
Capacity USGPM
0
10
20
30
40
50
60
70
80
90
100
Tota
l Hea
d (F
t)
0
10
20
30
40
50
60
70
80
EF
FIC
IEN
CY
(%
)
20
30
40
50
60
Bra
ke H
orse
pow
er (
BH
P)
Max. Dia. 191/295mm
BHP
Curve No: DLY-C612-9203Solid Dia 3" LL300Y
Min. Dia. 167/271mm
EFFICIENCY
300DLF637 (50HP) Synchronous Speed: 1800 RPM 12 inch Discharge
300DLF645 (60HP) Synchronous Speed: 1800 RPM 12 inch Discharge
EBARA Fluid Handlingwww.pumpsebara.com 2-190.1(t) 803 327 5005 • (f) 803 327 5097 rev. 01/02
EBARA Submersible Sewage Pumps DLFU
Dimensions
Project: Model: Chk’d: Date:
Model DLFU50DLFU, 2HP80DLFU, 2 to 30HP
PHASE
THREE
MODEL
50DLFU61.5
80DLFU61.5
80DLFU62.2
80DLFU63.7
80DLFU65.5
80DLFU67.5
80DLFU611
80DLFU615
80DLFU618
80DLFU622
kW
1.5
1.5
2.2
3.7
5.5
7.5
11
15
18.5
22
HP
2
2
3
5
71/2
10
15
20
25
30
A
1711/16
203/4
2313/16
2313/16
2313/16
251/16
261/8
261/8
271/4
271/4
B
101/8
111/2
133/16
133/16
133/16
141/2
153/16
153/16
1513/16
1513/16
C
125/8
15
173/16
173/16
173/16
173/4
189/16
189/16
195/16
195/16
D
51/16
53/4
65/8
65/8
65/8
75/16
75/8
75/8
715/16
715/16
E
95/8
111/4
133/8
133/8
133/8
14
143/4
143/4
159/16
159/16
F
77/8
811/16
913/16
913/16
913/16
1211/16
1211/16
1211/16
1211/16
1211/16
G5/16
5/16
5/16
5/16
3/8
3/8
5/16
5/16
5/16
5/16
H
2711/16
281/2
301/4
3113/16
371/8
361/16
399/16
425/16
437/8
437/8
J
71/16
81/4
91/4
91/4
91/4
913/16
105/8
105/8
117/16
117/16
L
65/16
71/16
81/16
81/16
11
101/4
913/16
1013/16
1013/16
1013/16
132
148
209
209
317
344
470
564
639
694
OUTPUT PUMP & MOTORSIZEø
2/3
3/4
WEIGHTLb
PHASE
THREE
MODEL
50DLFU61.5
80DLFU61.5
80DLFU62.2
80DLFU63.7
80DLFU65.5
80DLFU67.5
80DLFU611
80DLFU615
80DLFU618
80DLFU622
kW
1.5
1.5
2.2
3.7
5.5
7.5
11
15
18.5
22
HP
2
2
3
5
71/2
10
15
20
25
30
A
450
527
605
605
605
636
664
664
692
692
B
257
292
335
335
335
369
385
385
402
402
C
321
381
436
436
436
451
471
471
491
491
D
129
146
169
169
169
186
193
193
202
202
E
245
285
340
340
340
355
375
375
395
395
F
200
220
250
250
250
323
323
323
323
323
G
8
8
8
8
10
10
8
8
8
8
H
703
724
768
808
943
916
1005
1075
1115
1115
J
180
210
235
235
235
250
270
270
290
290
L
160
180
205
205
280
260
250
275
275
275
60
67
95
95
144
156
213
256
290
315
OUTPUT PUMP & MOTORSIZEø
50/80
80/100
WEIGHTkg
f
eø
(n) QTY - (h) HOLES
t
Dimensions: inch
Dimensions: mm
Flange (ANSI 125 PSI F.F)
ø
50
80
100
e
121
152
191
f
152
191
229
t
16
19
24
n
4
4
8
h
19
19
19
mm
ø
2
3
4
e
43/4
6
71/2
f
6
71/2
9
t5/8
3/4
15/16
n
4
4
8
h3/4
3/4
3/4
inch
*Note: All 80DLFU dimensions are based on 3'' discharge.
EBARA Fluid Handlingwww.pumpsebara.com 2-191(t) 803 327 5005 • (f) 803 327 5097 rev. 01/02
EBARA Submersible Sewage Pumps DLFU
Dimensions
Project: Model: Chk’d: Date:
Model DLMFU 80DLMFU, 2 to 71/2HP80DLCMFU, 10 to 15HP
Dimensions: inch
Dimensions: mm
Flange (ANSI 125 PSI F.F)
PHASE
THREE
MODEL
80DLMFU61.5
80DLMFU62.2
80DLMFU63.7
80DLMFU65.5
80DLCMFU67.5
80DLCMFU611
kW
1.5
2.2
3.7
5.5
7.5
11
HP
2
3
5
71/2
10
15
A
203/4
203/4
217/16
227/16
263/8
279/16
B
111/2
111/2
121/8
1215/16
1415/16
1511/16
C
15
15
153/8
16
187/8
1911/16
D
53/4
53/4
61/16
67/16
71/2
77/8
E
111/4
111/4
115/8
123/16
133/16
14
F
811/16
811/16
811/16
811/16
121/16
12
G5/16
5/16
5/16
3/8
3/8
5/16
H
281/2
291/2
311/16
363/8
355/8
395/16
J
81/4
81/4
811/16
91/4
101/4
11
L
71/16
71/2
71/2
101/4
97/16
97/16
157
187
205
311
375
500
OUTPUT PUMP & MOTORSIZEø
3/4
WEIGHTLb
PHASE
THREE
MODEL
80DLMFU61.5
80DLMFU62.2
80DLMFU63.7
80DLMFU65.5
80DLCMFU67.5
80DLCMFU611
kW
1.5
2.2
3.7
5.5
7.5
11
HP
2
3
5
71/2
10
15
A
527
527
545
570
670
700
B
292
292
308
328
379
399
C
381
381
391
406
480
500
D
146
146
154
164
190
200
E
285
285
295
310
335
355
F
220
220
220
220
307
305
G
8
8
8
10
10
8
H
724
750
789
924
905
998
J
210
210
220
235
260
280
L
180
190
190
261
240
240
71
85
93
141
170
227
OUTPUT PUMP & MOTORSIZEø
80/100
WEIGHTkg
f
eø
(n) QTY - (h) HOLES
t
ø
80
100
e
152
191
f
191
229
t
19
24
n
4
8
h
19
19
mm
ø
3
4
e
6
71/2
f
71/2
9
t3/4
15/16
n
4
8
h3/4
3/4
inch
*Note: All dimensions are based on 3'' discharge.
EBARA Fluid Handlingwww.pumpsebara.com 2-192(t) 803 327 5005 • (f) 803 327 5097 rev. 01/02
EBARA Submersible Sewage Pumps DLFU
Dimensions
Project: Model: Chk’d: Date:
Model DLFU 100DLFU, 2 to 60HP
PHASE
THREE
MODEL
100DLFU61.5
100DLFU62.2
100DLFU63.7
100DLFU65.5
100DLFU67.5
100DLFU611
100DLFU615
100DLFU618
100DLFU622
100DLFU630
100DLFU637
100DLFU645
kW
1.5
2.2
3.7
5.5
7.5
11
15
18.5
22
30
37
45
HP
2
3
5
71/2
10
15
20
25
30
40
50
60
A
213/4
227/8
227/8
289/16
289/16
289/16
293/4
307/8
307/8
331/4
331/4
331/4
B
101/2
111/8
111/8
1511/16
1511/16
1511/16
167/16
171/4
171/4
199/16
199/16
199/16
C
169/16
175/16
175/16
2011/16
2011/16
2011/16
217/16
221/4
221/4
235/8
235/8
235/8
D
51/4
59/16
59/16
77/8
77/8
77/8
81/4
811/16
811/16
95/8
95/8
95/8
E
12
1213/16
1213/16
161/8
161/8
161/8
1615/16
1711/16
1711/16
191/8
191/8
191/8
F
1013/16
1013/16
1013/16
15
15
15
1413/16
1413/16
1413/16
197/16
197/16
197/16
G5/16
5/16
5/16
3/8
3/8
5/16
5/16
5/16
5/16
5/16
5/16
5/16
H
2915/16
3013/16
323/8
377/16
377/16
411/8
431/4
4413/16
4413/16
553/4
595/16
595/16
J
77/8
811/16
811/16
11
11
11
1113/16
125/8
125/8
143/16
143/16
143/16
L
811/16
811/16
811/16
117/16
117/16
117/16
1113/16
1113/16
1113/16
195/16
205/16
205/16
170
198
216
353
395
476
602
677
736
1001
1171
1219
OUTPUT PUMP & MOTORSIZEø
3/4
4/6
4
WEIGHTLb
PHASE
THREE
MODEL
100DLFU61.5
100DLFU62.2
100DLFU63.7
100DLFU65.5
100DLFU67.5
100DLFU611
100DLFU615
100DLFU618
100DLFU622
100DLFU630
100DLFU637
100DLFU645
kW
1.5
2.2
3.7
5.5
7.5
11
15
18.5
22
30
37
45
HP
2
3
5
71/2
10
15
20
25
30
40
50
60
A
553
581
581
725
725
725
755
784
784
845
845
845
B
267
282
282
398
398
398
417
438
438
497
497
497
C
420
440
440
525
525
525
545
565
565
600
600
600
D
134
141
141
200
200
200
210
220
220
245
245
245
E
305
325
325
410
410
410
430
450
450
485
485
485
F
275
275
275
381
381
381
377
377
377
493
493
493
G
8
8
8
10
10
8
8
8
8
8
8
8
H
760
782
822
951
951
1044
1099
1139
1139
1416
1506
1506
J
200
220
220
280
280
280
300
320
320
360
360
360
L
220
220
220
290
290
290
300
300
300
490
516
516
77
90
98
160
179
216
273
307
334
454
531
553
OUTPUT PUMP & MOTORSIZEø
80/100
100/150
100
WEIGHTkg
Dimensions: inch
Dimensions: mm
Flange (ANSI 125 PSI F.F)
f
eø
(n) QTY - (h) HOLES
t
ø
80
100
150
e
152
191
241
f
191
229
279
t
19
24
25
n
4
8
8
h
19
19
22
mm
ø
3
4
6
e
6
71/2
91/2
f
71/2
9
11
t3/4
15/16
1
n
4
8
8
h3/4
3/4
7/8
inch
*Note: All dimensions are based on 4'' discharge.
EBARA Fluid Handlingwww.pumpsebara.com 2-193(t) 803 327 5005 • (f) 803 327 5097 rev. 11/02
EBARA Submersible Sewage Pumps DLFU
Dimensions
Project: Model: Chk’d: Date:
Model DLMFU 100DLMFU, 3 to 30HP
Dimensions: inch
Dimensions: mm
Flange (ANSI 125 PSI F.F)
f
eø
(n) QTY - (h) HOLES
tPHASE
THREE
MODEL
100DLMFU62.2
100DLMFU63.7
100DLMFU65.5
100DLMFU67.5
100DLMFU611
100DLMFU615
100DLMFU618
100DLMFU622
kW
2.2
3.7
5.5
7.5
11
15
18.5
22
HP
3
5
71/2
10
15
20
25
30
A
249/16
249/16
249/16
2513/16
267/8
267/8
28
28
B
133/16
133/16
133/16
141/2
153/16
153/16
1513/16
1513/16
C
1715/16
1715/16
1715/16
181/2
181/2
181/2
201/16
201/16
D
65/8
65/8
65/8
75/16
75/8
75/8
715/16
715/16
E
133/8
133/8
133/8
14
143/4
143/4
159/16
159/16
F
913/16
913/16
913/16
1211/16
1211/16
1211/16
1211/16
1211/16
G5/16
5/16
3/8
3/8
5/16
5/16
5/16
5/16
H
301/4
3113/16
371/8
361/16
399/16
425/16
437/8
437/8
J
91/4
91/4
91/4
913/16
105/8
105/8
117/16
117/16
L
81/16
81/16
11
101/4
913/16
1013/16
1013/16
1013/16
209
209
317
344
470
564
639
694
OUTPUT PUMP & MOTORSIZEø
3/4
WEIGHTLb
PHASE
THREE
MODEL
100DLMFU62.2
100DLMFU63.7
100DLMFU65.5
100DLMFU67.5
100DLMFU611
100DLMFU615
100DLMFU618
100DLMFU622
kW
2.2
3.7
5.5
7.5
11
15
18.5
22
HP
3
5
71/2
10
15
20
25
30
A
624
624
624
655
683
683
711
711
B
335
335
335
369
385
385
402
402
C
455
455
455
470
470
470
510
510
D
169
169
169
186
193
193
202
202
E
340
340
340
355
375
375
395
395
F
250
250
250
323
323
323
323
323
G
8
8
10
10
8
8
8
8
H
768
808
943
916
1005
1075
1115
1115
J
235
235
235
250
270
270
290
290
L
205
205
280
260
250
275
275
275
95
95
144
156
213
256
290
315
OUTPUT PUMP & MOTORSIZEø
80/100
WEIGHTkg
ø
80
100
e
152
191
f
191
229
t
19
24
n
4
8
h
19
19
mm
ø
3
4
e
6
71/2
f
71/2
9
t3/4
15/16
n
4
8
h3/4
3/4
inch
*Note: All dimensions are based on 4'' discharge.
EBARA Fluid Handlingwww.pumpsebara.com 2-193.1(t) 803 327 5005 • (f) 803 327 5097 rev. 01/02
EBARA Submersible Sewage Pumps DLFU
Dimensions
Project: Model: Chk’d: Date:
Model DLFU 150DLFU, 10 to 60HP
PHASE
THREE
MODEL
150DLFU67.5
150DLFU611
150DLFU615
150DLFU618
150DLFU622
150DLFU630
150DLFU637
150DLFU645
kW
7.5
11
15
18.5
22
30
37
45
HP
10
15
20
25
30
40
50
60
A
313/4
313/4
33
33
341/4
321/2
321/2
321/2
B
1615/16
1615/16
1713/16
1713/16
187/8
189/16
189/16
189/16
C
231/4
231/4
24
24
2413/16
231/4
231/4
231/4
D
89/16
89/16
9
9
91/2
95/16
95/16
95/16
E
1711/16
1711/16
181/2
181/2
195/16
173/4
173/4
173/4
F
165/16
165/16
161/8
161/8
163/16
237/8
237/8
237/8
G3/8
5/16
5/16
5/16
5/16
5/16
5/16
5/16
H
381/2
423/16
441/4
4513/16
453/4
529/16
557/8
557/8
J
1113/16
1113/16
125/8
125/8
133/8
133/4
133/4
133/4
L
123/8
123/8
125/8
125/8
125/8
161/8
1615/16
1615/16
428
549
635
712
787
1294
1345
1404
OUTPUT PUMP & MOTORSIZEø
6/8
WEIGHTLb
PHASE
THREE
MODEL
150DLFU67.5
150DLFU611
150DLFU615
150DLFU618
150DLFU622
150DLFU630
150DLFU637
150DLFU645
kW
7.5
11
15
18.5
22
30
37
45
HP
10
15
20
25
30
40
50
60
A
806
806
838
838
870
826
826
826
B
430
430
453
453
479
471
471
471
C
590
590
610
610
630
590
590
590
D
217
217
228
228
241
236
236
236
E
450
450
470
470
490
451
451
451
F
414
414
410
410
411
607
607
607
G
10
8
8
8
8
8
8
8
H
978
1071
1124
1164
1162
1335
1420
1420
J
300
300
320
320
340
350
350
350
L
315
315
320
320
320
409
430
430
194
249
288
323
357
587
610
637
OUTPUT PUMP & MOTORSIZEø
150/200
WEIGHTkg
Dimensions: inch
Dimensions: mm
Flange (ANSI 125 PSI F.F)
f
eø
(n) QTY - (h) HOLES
t
ø
150
200
e
241
298
f
279
343
t
25
29
n
8
8
h
22
22
mm
ø
6
8
e
91/2
113/4
f
11
131/2
t
1
11/8
n
8
8
h7/8
7/8
inch
EBARA Fluid Handlingwww.pumpsebara.com 2-194(t) 803 327 5005 • (f) 803 327 5097 rev. 01/02
EBARA Submersible Sewage Pumps DLFU
Dimensions
Project: Model: Chk’d: Date:
Model DLFU 200DLFU, 10 to 60HP
Dimensions: inch
Dimensions: mm
Flange (ANSI 125 PSI F.F)
PHASE
THREE
MODEL
200DLFU67.5
200DLFU611
200DLFU615
200DLFU618
200DLFU622
200DLFU630
200DLFU637
200DLFU645
kW
7.5
11
15
18.5
22
30
37
45
HP
10
15
20
25
30
40
50
60
A
33
337/16
341/4
343/4
349/16
353/16
353/16
353/16
B
1615/16
1615/16
1713/16
1713/16
187/8
209/16
209/16
209/16
C
241/2
241/2
251/4
251/4
261/16
247/8
247/8
247/8
D
89/16
9
9
91/2
89/16
105/16
105/16
105/16
E
1711/16
1711/16
181/2
181/2
195/16
181/8
181/8
181/8
F
165/16
165/16
161/8
161/8
163/16
263/16
263/16
263/16
G3/8
5/16
5/16
5/16
5/16
5/16
5/16
5/16
H
381/2
423/16
441/4
4513/16
453/4
541/8
571/2
571/2
J
1113/16
1113/16
125/8
125/8
133/8
143/16
143/16
143/16
L
123/8
123/8
125/8
125/8
125/8
1711/16
181/2
181/2
428
549
635
712
787
1347
1398
1457
OUTPUT PUMP & MOTORSIZEø
6/8
WEIGHTLb
PHASE
THREE
MODEL
200DLFU67.5
200DLFU611
200DLFU615
200DLFU618
200DLFU622
200DLFU630
200DLFU637
200DLFU645
kW
7.5
11
15
18.5
22
30
37
45
HP
10
15
20
25
30
40
50
60
A
838
850
870
882
878
895
895
895
B
430
430
453
453
479
522
522
522
C
622
622
642
642
662
632
632
632
D
217
228
228
241
217
262
262
262
E
450
450
470
470
490
461
461
461
F
414
414
410
410
411
665
665
665
G
10
8
8
8
8
8
8
8
H
978
1071
1124
1164
1162
1375
1460
1460
J
300
300
320
320
340
360
360
360
L
315
315
320
320
320
449
470
470
194
249
288
323
357
611
634
661
OUTPUT PUMP & MOTORSIZEø
150/200
WEIGHTkg
ø
150
200
e
241
298
f
279
343
t
25
29
n
8
8
h
22
22
mm
ø
6
8
e
91/2
113/4
f
11
131/2
t
1
11/8
n
8
8
h7/8
7/8
inch
f
eø
(n) QTY - (h) HOLES
t
EBARA Fluid Handlingwww.pumpsebara.com 2-195(t) 803 327 5005 • (f) 803 327 5097 rev. 01/02
EBARA Submersible Sewage Pumps DLFU
Dimensions
Project: Model: Chk’d: Date:
Model DLFU 250DLFU, 15 to 60HP
PHASE
THREE
MODEL
250DLFU611
250DLBFU615
250DLCFU615
250DLFU618
250DLFU622
250DLFU630
250DLFU637
250DLFU645
kW
11
15
15
18.5
22
30
37
45
HP
15
20
20
25
30
40
50
60
A
381/4
381/4
393/16
393/16
393/16
423/8
423/8
423/8
B
205/8
205/8
215/16
215/16
215/16
2311/16
2311/16
2311/16
C
2711/16
2711/16
287/16
287/16
287/16
301/2
301/2
301/2
D
109/16
109/16
103/4
103/4
103/4
1115/16
1115/16
1115/16
E
1911/16
1911/16
201/2
201/2
201/2
221/2
221/2
221/2
F
241/2
241/2
2415/16
2415/16
2415/16
2913/16
2913/16
2913/16
G5/16
5/16
5/16
5/16
5/16
5/16
5/16
5/16
H
451/4
4711/16
477/8
497/16
497/16
571/16
603/8
603/8
J
149/16
149/16
153/8
153/8
153/8
175/16
175/16
175/16
L
153/8
161/8
165/16
165/16
165/16
209/16
217/16
217/16
736
833
877
959
1030
1570
1631
1713
OUTPUT PUMP & MOTORSIZEø
10
WEIGHTLb
PHASE
THREE
MODEL
250DLFU611
250DLBFU615
250DLCFU615
250DLFU618
250DLFU622
250DLFU630
250DLFU637
250DLFU645
kW
11
15
15
18.5
22
30
37
45
HP
10
20
20
25
30
40
50
60
A
972
972
996
996
996
1077
1077
1077
B
524
524
541
541
541
602
602
602
C
703
703
723
723
723
774
774
774
D
269
269
273
273
273
304
304
304
E
500
500
520
520
520
571
571
571
F
622
622
634
634
634
757
757
757
G
8
8
8
8
8
8
8
8
H
1149
1211
1216
1256
1256
1449
1534
1534
J
370
370
390
390
390
440
440
440
L
390
410
415
415
415
523
544
544
334
378
398
435
467
712
740
777
OUTPUT PUMP & MOTORSIZEø
250
WEIGHTkg
f
eø
(n) QTY - (h) HOLES
tDimensions: inch
Dimensions: mm
Flange (ANSI 125 PSI F.F)
ø
250
e
362
f
406
t
30
n
12
h
25
mm
ø
10
e
141/4
f
16
t
13/16
n
12
h
1
inch
EBARA Fluid Handlingwww.pumpsebara.com 2-196(t) 803 327 5005 • (f) 803 327 5097 rev. 01/02
EBARA Submersible Sewage Pumps DLFU
Dimensions
Project: Model: Chk’d: Date:
Model DLFU300DLFU, 25 to 60HP
Dimensions: inch
Dimensions: mm
Flange (ANSI 125 PSI F.F)
PHASE
THREE
MODEL
300DLFU618
300DLFU622
300DLFU630
300DLFU637
300DLFU645
kW
18.5
22
30
37
45
HP
25
30
40
50
60
A
44
44
491/8
491/8
491/8
B
231/8
231/8
275/16
275/16
275/16
C
323/16
323/16
355/16
355/16
355/16
D
117/8
117/8
1313/16
1313/16
1313/16
E
225/8
225/8
2513/16
2513/16
2513/16
F
267/16
267/16
341/8
341/8
341/8
G5/16
5/16
5/16
5/16
5/16
H
511/8
511/8
6013/16
641/8
641/8
J
169/16
169/16
1911/16
1911/16
1911/16
L
1715/16
1715/16
245/16
253/16
253/16
1047
1107
1733
1795
1876
OUTPUT PUMP & MOTORSIZEø
12
WEIGHTLb
PHASE
THREE
MODEL
300DLFU618
300DLFU622
300DLFU630
300DLFU637
300DLFU645
kW
18.5
22
30
37
45
HP
25
30
40
50
60
A
1118
1118
1248
1248
1248
B
587
587
693
693
693
C
817
817
897
897
897
D
302
302
351
351
351
E
575
575
656
656
656
F
671
671
867
867
867
G
8
8
8
8
8
H
1298
1298
1544
1629
1629
J
420
420
500
500
500
L
455
455
618
639
639
475
502
786
814
851
OUTPUT PUMP & MOTORSIZEø
300
WEIGHTkg
f
eø
(n) QTY - (h) HOLES
t
ø
300
e
432
f
483
t
32
n
12
h
25
mm
ø
12
e
17
f
19
t
11/4
n
12
h
1
inch
EBARA Fluid Handlingwww.pumpsebara.com 2-197(t) 803 327 5005 • (f) 803 327 5097 rev. 01/02
EBARA Submersible Sewage Pumps DLFU
Dimensions
Project: Model: Chk’d: Date:
Model DLFU with Quick Discharge Connector 50DLFU, 2HP80DLFU, 2HP100DLFU, 2 to 5HP
Dimensions: inch
Dimensions: mm
Flange (ANSI 125 PSI F.F)
PHASE
THREE
MODEL
50DLFU61.5
80DLFU61.5
100DLFU61.5
100DLFU62.2
100DLFU63.7
kW
1.5
1.5
1.5
2.2
3.7
HP
2
2
2
3
5
LM65
LM80
LM80
LM80
LM80
A
87/16
87/16
87/16
87/16
87/16
B
6
65/8
81/4
81/4
81/4
C
33/4
39/16
39/16
39/16
39/16
H1/2
9/16
9/16
9/16
9/16
J
51/2
61/8
61/8
61/8
61/8
M1
65/16
61/2
711/16
711/16
711/16
M2
33/4
39/16
39/16
39/16
39/16
N1
43/4
415/16
415/16
415/16
415/16
N2
13/4
115/16
115/16
115/16
115/16
P
511/16
67/8
67/8
67/8
67/8
R
913/16
111/4
1113/16
1113/16
1113/16
S
71/2
91/16
91/16
91/16
91/16
F
101/8
111/2
101/2
111/8
111/8
ø1
21/2
3
3
3
3
G
181/4
201/8
197/16
201/2
201/2
L
81/4
95/8
95/8
95/8
95/8
Q
71/16
81/4
77/8
811/16
811/16
T
295/8
311/16
307/8
313/4
333/8
U
115/16
29/16
1
1
1
OUTPUT QDCMODEL
QDCSIZEø
2/3
3/4
WEIGHT LbPUMP & MOTORPUMP
132
148
170
198
216
QDC
31
37
37
37
37
ø
50
80
100
e
121
152
191
f
152
191
229
t
16
19
24
n
4
4
8
h
19
19
19
mm
ø
2
3
4
e
43/4
6
71/2
f
6
71/2
9
t5/8
3/4
15/16
n
4
4
8
h3/4
3/4
3/4
inch
PHASE
THREE
MODEL
50DLFU61.5
80DLFU61.5
100DLFU61.5
100DLFU62.2
100DLFU63.7
kW
1.5
1.5
1.5
2.2
3.7
HP
2
2
2
3
5
LM65
LM80
LM80
LM80
LM80
A
215
215
215
215
215
B
153
168
210
210
210
C
95
90
90
90
90
H
12
15
15
15
15
J
140
155
155
155
155
M1
160
165
195
195
195
M2
95
90
90
90
90
N1
120
125
125
125
125
N2
45
50
50
50
50
P
145
175
175
175
175
R
250
285
300
300
300
S
190
230
230
230
230
F
257
292
267
282
282
ø1
65
80
80
80
80
G
464
511
494
521
521
L
210
245
245
245
245
Q
180
210
200
220
220
T
753
789
785
807
847
U
50
65
25
25
25
OUTPUT QDCMODEL
QDCSIZEø
50/80
80/100
WEIGHT kgPUMP & MOTORPUMP
60
67
77
90
98
QDC
14
17
17
17
17
f
eø
(n) QTY - (h) HOLES
t
Guide pipe support
4 – H Holes
Bolt 2 – 5/8 (16)
ø1
P.C.D. J
23/8 (60)
F
Submersible Cable
L . W. L.
315/16
(100)
51/2 (140)
23/16 (56)
SGP (W) 1"
Bolt 2–1/2 x 13/16
(12x30)
19 /16(4
0)
39 /16(9
0)
Gui
de p
ipe
leng
thG
13/8 (35)
29 /16(6
5)
279 /16
(700
) 2
9 /16(6
5)29/16 (65) 311/2 (800) 29/16 (65)
Floor FrameManhole dimensions infloor frame installation
M 1 N 1
M 2 N 2
ø
B A
C
U
L
T
23/4 (70)
115/16
(50)
23 /4(7
0)
R
S P
Q
*Note: All 80DLFU dimensions are based on 3'' discharge.
All 100DLFU dimensions are based on 4'' discharge.
EBARA Fluid Handlingwww.pumpsebara.com 2-198(t) 803 327 5005 • (f) 803 327 5097 rev. 01/02
EBARA Submersible Sewage Pumps DLFU
Dimensions
Project: Model: Chk’d: Date:
Model DLFU with Quick Discharge Connector 80DLMFU, 2 to 71/2HP
Guide pipe support
4 - 9/16 (15)Holes
Bolt 2 – 5/8 (16)
P.C.D. 6 1/8 (155)
FSubmersible Cable
L . W. L.
315/16 (100)
51/2 (140)
23/16 (56)
SGP (W) 1"
Bolt 2–1/2 x 13/16
(12x30)
19 /16(4
0)
39 /16(9
0)
Gui
de p
ipe
leng
th
G
29 /16(6
5)
279 /16
(700
) 2
9 /16(6
5)
29/16 (65) 311/2 (800) 29/16 (65)
Floor Frame
Manhole dimensions
floor frame installation
ø
63/4 (171) 87/16 (215) 29 /16(6
5)
L
T
23 /4 (70
)r
91 /16(2
30)
67 /8(1
75)
13/8 (35)
115/16
(50)
23/4 (70)
m 415/16 (125) Q
115/16 (50)39/16 (90)
3 (80)
Dimensions: inch
Dimensions: mm
Flange (ANSI 125 PSI F.F)
PHASE
THREE
PUMP MODEL
80DLMFU61.5
80DLMFU62.2
80DLMFU63.7
80DLMFU65.5
kW
1.5
2.2
3.7
5.5
HP
2
3
5
71/2
Q.D.C.MODEL
LM80
LM80
LM80
LM80
F
111/2
111/2
121/8
1215/16
G
205/16
205/16
21
22
L
913/16
915/16
915/16
127/8
Q
81/4
81/4
811/16
91/4
T
311/16
321/16
335/8
3815/16
PUMP
157
187
205
311
Q.D.C.
37
37
37
37
OUTPUT PUMP & MOTORSIZEø
3/4
WEIGHT Lb
PHASE
THREE
PUMP MODEL
80DLMFU61.5
80DLMFU62.2
80DLMFU63.7
80DLMFU65.5
kW
1.5
2.2
3.7
5.5
HP
2
3
5
71/2
Q.D.C.MODEL
LM80
LM80
LM80
LM80
F
292
292
308
328
G
516
516
534
559
L
250
253
252
327
Q
210
210
220
235
T
789
815
854
989
PUMP
71
85
93
141
Q.D.C.
17
17
17
17
OUTPUT PUMP & MOTORSIZEø
80/100
WEIGHT kg
f
eø
(n) QTY - (h) HOLES
t
39/16 (90)
23/8 (60)
ø
3
4
e
6
71/2
f
71/2
9
t3/4
15/16
n
4
8
h3/4
3/4
r
113/16
1113/16
m
61/2
711/16
inch
ø
80
100
e
152
191
f
191
229
t
19
24
n
4
8
h
19
19
r
284
300
m
165
195
mm
EBARA Fluid Handlingwww.pumpsebara.com 2-199(t) 803 327 5005 • (f) 803 327 5097 rev. 11/02
EBARA Submersible Sewage Pumps DLFU
Dimensions
Project: Model: Chk’d: Date:
Model DLFU with Quick Discharge Connector 80DLCMFU, 10 to 15HP
Guide pipe support
4 – 9/16 (15)Holes
Bolt 2 – 5/8 (16)
P.C.D. 6 1/8 (155)
57/8 (150)
29/16 (65) 311/2 (800) 29/16 (65)
F
Submersible Cable
L . W. L.
71/16 (180)
911/16 (246)
33/8 (85)
SGP (W) 11/2"
Bolt 2–5/8 x 13/16
(16x30)
Guid
e p
ipe length
G
29 /16(6
5)
27
9 /16(7
00)
29 /16(6
5)
Floor Frame
Manhole dimensions in
floor frame installation
Q
ø
63/4 (171) 12 (305)
T
r
L
U
315/16
(100
)
101 /16
(255
)
97 /16(2
40)
23/16 (55)
23 /4(7
0)
65/16 (160)
43/4 (120)
m 715/16 (185)
31/8 (80)
3 (80)
Dimensions: inch
Dimensions: mm
Flange (ANSI 125 PSI F.F)
PHASE
THREE
MODEL
80DLCMFU67.5
80DLCMFU611
kW
7.5
11
HP
10
15
Q.D.C.MODEL
LL80
LL80
F
1415/16
1511/16
G
273/16
283/8
L
111/8
111/4
Q
101/4
11
T
375/16
411/16
U
111/16
13/4
PUMP
375
500
Q.D.C.
97
97
OUTPUT PUMP & MOTORSIZEø
3/4
WEIGHT Lb
PHASE
THREE
MODEL
80DLCMFU67.5
80DLCMFU611
kW
7.5
11
HP
10
15
Q.D.C.MODEL
LL80
LL80
F
379
399
G
690
720
L
283
285
Q
260
280
T
948
1043
U
43
45
PUMP
170
227
Q.D.C.
44
44
OUTPUT PUMP & MOTORSIZEø
80/100
WEIGHT Lb
f
eø
(n) QTY - (h) HOLESt
23/16 (55)61/2 (165)
ø
3
4
e
6
71/2
f
71/2
9
t3/4
15/16
n
4
8
h3/4
3/4
r
133/4
143/8
m
711/16
87/8
inch
ø
80
100
e
152
191
f
191
229
t
19
24
n
4
8
h
19
19
r
350
365
m
195
226
mm
EBARA Fluid Handlingwww.pumpsebara.com 2-200(t) 803 327 5005 • (f) 803 327 5097 rev. 01/02
EBARA Submersible Sewage Pumps DLFU
Dimensions
Project: Model: Chk’d: Date:
Model DLFU with Quick Discharge Connector 80DLFU, 3 to 30HP
Guide pipe support
4 – 3/4 (19) Holes
Bolt 4 – 5/8 (16)
P.C.D. 6 7/8 (175)
57/8 (150)Submersible Cable
L.W.L.
71/16 (180)
911/16 (246) Bolt 2–5/8 x 13/16
(16x30)
Gu
ide
pip
e le
ng
th
29 /16(6
5)
279 /16
(700
) 2
9 /16(6
5)
Floor Frame
Manhole dimensions infloor frame installation
81/4 (210) 117/16 (290)
U
L
T
143 /8
(365
)
107 /16
(265
)
97 /16(2
40)
315/16
(100
)
ø 4 (100)
PHASE
THREE
MODEL
80DLFU62.2
80DLFU63.7
80DLFU65.5
80DLFU67.5
80DLFU611
80DLFU615
80DLFU618
80DLFU622
kW
2.2
3.7
5.5
7.5
11
15
18.5
22
HP
3
5
71/2
10
15
20
25
30
Q.D.C.MODEL
LL100
LL100
LL100
LL100
LL100
LL100
LL100
LL100
F
133/16
133/16
133/16
141/2
153/16
153/16
1513/16
1513/16
G
253/8
253/8
253/8
269/16
2711/16
2711/16
283/4
283/4
L
125/8
125/8
159/16
1113/16
115/8
123/8
123/8
123/8
Q
91/4
91/4
91/4
913/16
105/8
105/8
117/16
117/16
T
343/4
365/16
415/8
3711/16
415/16
441/8
4511/16
4511/16
U
41/2
41/2
41/2
15/8
15/8
15/8
15/8
15/8
PUMP
209
209
317
344
470
564
639
694
Q.D.C.
101
101
101
101
101
101
101
101
OUTPUT PUMP & MOTORSIZEø
3/4
WEIGHT Lb
PHASE
THREE
MODEL
80DLFU62.2
80DLFU63.7
80DLFU65.5
80DLFU67.5
80DLFU611
80DLFU615
80DLFU618
80DLFU622
kW
2.2
3.7
5.5
7.5
11
15
18.5
22
HP
3
5
71/2
10
15
20
25
30
Q.D.C.MODEL
LL100
LL100
LL100
LL100
LL100
LL100
LL100
LL100
F
335
335
335
369
385
385
402
402
G
644
644
644
675
703
703
730
730
L
320
320
395
300
295
315
315
315
Q
235
235
235
250
270
270
290
290
T
883
923
1058
958
1050
1120
1160
1160
U
115
115
115
42
42
42
42
42
PUMP
95
95
144
156
213
256
290
315
Q.D.C.
46
46
46
46
46
46
46
46
OUTPUT PUMP & MOTORSIZEø
80/100
WEIGHT kg
f
eø
(n) QTY - (h) HOLES
tDimensions: inch
Dimensions: mm
Flange (ANSI 125 PSI F.F)
33/8 (85)
Q
G
F
ø
81/4 (210) 75/16 (185)
41/8 (105)
SGP (W) 11/2"
29/16 (65) 311/2 (800) 29/16 (65)
65/16 (160)
23/16 (55)
ø
80
100
e
152
191
f
191
229
t
19
24
n
4
8
h
19
19
mm
ø
3
4
e
6
71/2
f
71/2
9
t3/4
15/16
n
4
8
h3/4
3/4
inch
61/2 (165) 23/16 (55)
31/8 (80)
23 /4(7
0)
EBARA Fluid Handlingwww.pumpsebara.com 2-201(t) 803 327 5005 • (f) 803 327 5097 rev. 12/03
EBARA Submersible Sewage Pumps DLFU
Dimensions
Project: Model: Chk’d: Date:
Model DLFU with Quick Discharge Connector 100DLMFU, 3 to 30HP
f
eø
(n) QTY - (h) HOLES
tDimensions: inch
Dimensions: mm
Flange (ANSI 125 PSI F.F)
PHASE
THREE
MODEL
100DLMFU62.2
100DLMFU63.7
100DLMFU65.5
100DLMFU67.5
100DLMFU611
100DLMFU615
100DLMFU618
100DLMFU622
kW
2.2
3.7
5.5
7.5
11
15
18.5
22
HP
3
5
71/2
10
15
20
25
30
Q.D.C.MODEL
LL100
LL100
LL100
LL100
LL100
LL100
LL100
LL100
F
133/16
133/16
133/16
141/2
153/16
153/16
1513/16
1513/16
G
253/8
253/8
253/8
269/16
2711/16
2711/16
283/4
283/4
L
125/8
125/8
159/16
1113/16
115/8
123/8
123/8
123/8
Q
91/4
91/4
91/4
913/16
105/8
105/8
117/16
117/16
T
343/4
365/16
415/8
3711/16
415/16
441/8
4511/16
4511/16
U
41/2
41/2
41/2
15/8
15/8
15/8
15/8
15/8
PUMP
209
209
317
344
470
564
639
694
Q.D.C.
101
101
101
101
101
101
101
101
OUTPUT PUMP & MOTORSIZEø
WEIGHT Lb
PHASE
THREE
MODEL
100DLMFU62.2
100DLMFU63.7
100DLMFU65.5
100DLMFU67.5
100DLMFU611
100DLMFU615
100DLMFU618
100DLMFU622
kW
2.2
3.7
5.5
7.5
11
15
18.5
22
HP
3
5
71/2
10
15
20
25
30
Q.D.C.MODEL
LL100
LL100
LL100
LL100
LL100
LL100
LL100
LL100
F
335
335
335
369
385
385
402
402
G
644
644
644
675
703
703
730
730
L
320
320
395
300
295
315
315
315
Q
235
235
235
250
270
270
290
290
T
883
923
1058
958
1050
1120
1160
1160
U
115
115
115
42
42
42
42
42
PUMP
95
95
144
156
213
256
290
315
Q.D.C.
46
46
46
46
46
46
46
46
OUTPUT PUMP & MOTORSIZEø
WEIGHT kg
Guide pipe support
4 – 3/4 (19) Holes
Bolt 4 – 5/8 (16)
P.C.D. 6 7/8 (175)
57/8 (150)Submersible Cable
L.W.L.
71/16 (180)
911/16 (246) Bolt 2–5/8 x 13/16
23/16 (55)
(16x30)
Guid
e p
ipe le
ngth
Floor Frame
Manhole dimensions infloor frame installation
U
L
T
23 /4 (7
0)
143 /8
(365
)
107 /16
(265
)
97 /16(2
40)
315/16
(100
)
ø 4 (100)
33/8 (85)
Q
G
81/4 (210) 75/16 (185)
SGP (W) 11/2"
29/16 (65) 311/2 (800) 29/16 (65)
65/16 (160)
29 /16(6
5)
27
9 /16(7
00)
29 /16
(65)
F
ø
80
100
150
e
152
191
240
f
191
229
280
t
19
24
24
n
4
8
8
h
19
19
19
mm
ø
3
4
6
e
6
71/2
91/2
f
71/2
9
11
t3/4
15/16
1
n
4
8
8
h3/4
3/4
3/4
inch
ø 41/8 (105) 31/8 (80)
81/4 (210) 117/16 (290)
61/2 (165) 23/16 (55)
EBARA Fluid Handlingwww.pumpsebara.com 2-201.1(t) 803 327 5005 • (f) 803 327 5097 rev. 03/13
80
100
150
3
4
6
EBARA Submersible Sewage Pumps DLFU
Dimensions
Project: Model: Chk’d: Date:
Model DLFU with Quick Discharge Connector 100DLFU, 71/2 to 30HP
PHASE
THREE
MODEL
100DLFU65.5
100DLFU67.5
100DLFU611
100DLFU615
100DLFU618
100DLFU622
kW
5.5
7.5
11
15
18.5
22
HP
71/2
10
15
20
25
30
Q.D.C.MODEL
LL125
LL125
LL125
LL125
LL125
LL125
F
398
398
398
418
438
438
G
681
681
681
711
741
741
L
366
366
366
372
372
372
Q
280
280
280
300
320
320
T
1021
1021
1114
1173
1213
1213
U
69
69
69
73
73
73
PUMP
160
179
216
273
307
334
Q.D.C.
65
65
65
65
65
65
OUTPUT PUMP & MOTORSIZEø
100/150
WEIGHT kg
Dimensions: inch
Dimensions: mm
Flange (ANSI 125 PSI F.F)
PHASE
THREE
MODEL
100DLFU65.5
100DLFU67.5
100DLFU611
100DLFU615
100DLFU618
100DLFU622
kW
5.5
7.5
11
15
18.5
22
HP
71/2
10
15
20
25
30
Q.D.C.MODEL
LL125
LL125
LL125
LL125
LL125
LL125
F
1511/16
1511/16
1511/16
167/16
171/4
171/4
G
2613/16
2613/16
2613/16
28
293/16
293/16
L
143/8
143/8
143/8
145/8
145/8
145/8
Q
11
11
11
1113/16
125/8
125/8
T
403/16
403/16
4313/16
463/16
473/4
473/4
U
211/16
211/16
211/16
27/8
27/8
27/8
PUMP
353
395
476
602
677
736
Q.D.C.
143
143
143
143
143
143
OUTPUT PUMP & MOTORSIZEø
4/6
WEIGHT Lb
f
eø
(n) QTY - (h) HOLES
t
ø
4
6
e
71/2
91/2
f
9
11
t15/16
1
n88
h3/4
7/8
m1213/16
139/16
r
1711/16
185/16
ø
100
150
e
191
241
f
229
279
t
24
25
n
8
8
h
19
22
r
450
465
m
326
345
k95/8
113/8
inch
m
245
290
mm
EBARA Fluid Handlingwww.pumpsebara.com 2-202(t) 803 327 5005 • (f) 803 327 5097 rev. 04/15
EBARA Submersible Sewage Pumps DLFU
Dimensions
Project: Model: Chk’d: Date:
Model DLFU with Quick Discharge Connector 100DLFU, 40 to 60HP
Dimensions: inch
Dimensions: mm
Flange (ANSI 125 PSI F.F)
f
eø
(n) QTY - (h) HOLES
t
EBARA Fluid Handlingwww.pumpsebara.com 2-203(t) 803 327 5005 • (f) 803 327 5097 rev. 04/15
ø
4
6
e
71/2
91/2
f
9
11
t15/16
1
n88
h3/4
7/8
m1213/16
139/16
r
1711/16
185/16
ø
100
150
e
191
241
f
229
279
t
24
25
n
8
8
h
19
22
r
450
465
m
325
345
k95/8
113/8
inch
m
245
290
mm
PHASE
THREE
MODEL
100DLFU630
100DLFU637
100DLFU645
kW
30
37
45
HP
40
50
60
Q.D.C.MODEL
LL125HH
LL125HH
LL125HH
F
497
497
497
G
911
911
911
L
1211
1301
1301
Q
360
360
360
T
1373
1462
1462
U
157
157
157
PUMP
454
531
553
Q.D.C.
83
83
83
OUTPUT PUMP & MOTORSIZEø
100
WEIGHT kg
PHASE
THREE
MODEL
100DLFU630
100DLFU637
100DLFU645
kW
30
37
45
HP
40
50
60
Q.D.C.MODEL
LL125HH
LL125HH
LL125HH
F
199/16
199/16
199/16
G
357/8
357/8
357/8
L
4711/16
513/16
513/16
Q
143/16
143/16
143/16
T
541/16
579/16
579/16
U
63/16
63/16
63/16
PUMP
1001
1171
1219
Q.D.C.
183
183
183
OUTPUT PUMP & MOTORSIZEø
4
WEIGHT Lb
EBARA Submersible Sewage Pumps DLFU
Dimensions
Project: Model: Chk’d: Date:
Model DLFU with Quick Discharge Connector 150DLFU, 10 to 30HP
Guide pipe support
4 – 3/4 (19) Holes
P.C.D. 9 13/16
39/16 (90)
19 /16(4
0)
39 /16(9
0)
29/16 (65) 435/16 (1100) 29/16 (65)
F
Submersible Cable
L . W. L.
109/16 (268)
14 (355)
SGP (W) 2"
Bolt 2–5/8 x 13/16
(16x30)
125 /8
(320
)
1515/16
(405
)G
uid
e p
ipe length
G
29 /16(6
5)
311 /2
(800
) 2
9 /16(6
5)
Floor FrameManhole dimensions in
floor frame installation
Q
ø
LT
23 /4(7
0)
115/16 (50)
123/8 (315)
81/16
(205)61/8
(155)
315/16
(100
)
ø 6 (150)
U
143/16 (360)
191 /2
(495
)
65/16 (160)
5 7/8(150)
Bolt 4–5/8
(16)1113/16 (300)
Dimensions: inch
Dimensions: mm
Flange (ANSI 125 PSI F.F)
PHASE
THREE
MODEL
150DLFU67.5
150DLFU611
150DLFU615
150DLFU618
150DLFU622
kW
7.5
11
15
18.5
22
HP
10
15
20
25
30
Q.D.C.MODEL
LL150
LL150
LL150
LL150
LL150
F
1615/16
1615/16
1713/16
1713/16
187/8
G
287/16
287/16
295/8
295/8
3015/16
L
159/16
159/16
161/16
161/16
1515/16
Q
1113/16
1113/16
125/8
125/8
133/8
T
4111/16
453/8
475/8
493/16
491/16
U
33/16
33/16
33/8
33/8
35/16
PUMP
428
549
635
712
787
Q.D.C.
176
176
176
176
176
OUTPUT PUMP & MOTORSIZEø
6/8
WEIGHT Lb
PHASE
THREE
MODEL
150DLFU67.5
150DLFU611
150DLFU615
150DLFU618
150DLFU622
kW
7.5
11
15
18.5
22
HP
10
15
20
25
30
Q.D.C.MODEL
LL150
LL150
LL150
LL150
LL150
F
430
430
453
453
479
G
722
722
753
753
786
L
396
396
408
408
405
Q
300
300
320
320
340
T
1059
1152
1209
1249
1246
U
81
81
85
85
84
PUMP
194
249
288
323
357
Q.D.C.
80
80
80
80
80
OUTPUT PUMP & MOTORSIZEø
150/200
WEIGHT kg
ø
6
8
e
91/2
113/4
f
11
131/2
t
1
11/8
n
8
8
h7/8
7/8
inch
mm
ø
150
200
e
241
298
f
279
343
t
25
29
n
8
8
h
22
22
f
eø
(n) QTY - (h) HOLES
t
811/16 (220) 611/16 (170)
EBARA Fluid Handlingwww.pumpsebara.com 2-204(t) 803 327 5005 • (f) 803 327 5097 rev. 01/02
EBARA Submersible Sewage Pumps DLFU
Dimensions
Project: Model: Chk’d: Date:
Model DLFU with Quick Discharge Connector 200DLFU, 10 to 30HP
Dimensions: inch
Dimensions: mm
Flange (ANSI 125 PSI F.F)
PHASE
THREE
MODEL
200DLFU67.5
200DLFU611
200DLFU615
200DLFU618
200DLFU622
kW
7.5
11
15
18.5
22
HP
10
15
20
25
30
Q.D.C.MODEL
LL150
LL150
LL150
LL150
LL150
F
1615/16
1615/16
1713/16
1713/16
187/8
G
287/16
287/16
295/8
295/8
3015/16
L
159/16
159/16
161/16
161/16
1515/16
Q
1113/16
1113/16
125/8
125/8
133/8
T
4111/16
453/8
475/8
493/16
491/16
U
33/16
33/16
33/8
33/8
35/16
PUMP
428
549
635
712
787
Q.D.C.
176
176
176
176
176
OUTPUT PUMP & MOTORSIZEø
6/8
WEIGHT Lb
PHASE
THREE
MODEL
200DLFU67.5
200DLFU611
200DLFU615
200DLFU618
200DLFU622
kW
7.5
11
15
18.5
22
HP
10
15
20
25
30
Q.D.C.MODEL
LL150
LL150
LL150
LL150
LL150
F
430
430
453
453
479
G
722
722
753
753
786
L
396
396
408
408
405
Q
300
300
320
320
340
T
1059
1152
1209
1249
1246
U
81
81
85
85
84
PUMP
194
249
288
323
357
Q.D.C.
80
80
80
80
80
OUTPUT PUMP & MOTORSIZEø
150/200
WEIGHT kg
ø
6
8
e
91/2
113/4
f
11
131/2
t
1
11/8
n
8
8
h7/8
7/8
inch
mm
ø
150
200
e
241
298
f
279
343
t
25
29
n
8
8
h
22
22
f
eø
(n) QTY - (h) HOLES
t
Guide pipe support
39/16 (90)
19 /16(4
0)
39 /16(9
0)
29/16 (65) 435/16 (1100) 29/16 (65)
F
Submersible Cable
109/16 (268)
SGP (W) 2"
Bolt 2–5/8 x 13/16
(16x30)
Guid
e p
ipe length
G
29 /16(6
5)
31
1 /2(8
00)
2
9 /16(6
5)
Floor FrameManhole dimensions in
floor frame installation
23 /4(7
0)
115/16 (50)
65/16 (160)
57/8(150)
4 – 3/4 (19) Holes
P.C.D. 9 13/16
L . W. L.
14 (355)
125 /8
(320
)
1515/16
(405
)
Q
ø
LT
123/8 (315)
81/16
(205)61/8
(155)
315/16
(100
)
ø 6 (150)
U
143/16 (360)
191 /2
(495
)
Bolt 4–5/8
(16)1113/16 (300)
811/16 (220) 611/16 (170)
EBARA Fluid Handlingwww.pumpsebara.com 2-205(t) 803 327 5005 • (f) 803 327 5097 rev. 01/02
EBARA Submersible Sewage Pumps DLFU
Dimensions
Project: Model: Chk’d: Date:
Model DLFU with Quick Discharge Connector 150DLFU, 40 to 60HP200DLFU, 40 to 60HP
A2
B2
Bolt 4 – 15/16 (24)
65/16 (160)
F E1
E2
L . W. L.
315/16
(100)
57/8 (150)
39/16 (90)
SGP (W) 2"
Bolt 2–5/8 x 13/16
(16x30)3 /16
(5)
Floor Frame
Floor plateGuide pipe support
Q
ø
P
U
L
T
123 /8
(315
)
19 /16(4
0)
45 /16(1
10)
R
S
D1
G
D2
23 /8(6
0)
A1
B1
61/8 (155)
N
Dimensions: inch
Dimensions: mm
Flange (ANSI 125 PSI F.F)
PHASE
THREE
MODEL
150DLFU630
150DLFU637
150DLFU645
200DLFU630
200DLFU637
200DLFU645
kW
30
37
45
30
37
45
HP
40
50
60
40
50
60
LL150YU
LL150YU
LL150YU
LL200YU
LL200YU
LL200YU
A1
161/8
161/8
161/8
175/16
175/16
175/16
A2
143/16
143/16
143/16
169/16
169/16
169/16
B1
201/2
201/2
201/2
215/8
215/8
215/8
B2
161/8
161/8
161/8
181/2
181/2
181/2
F
189/16
189/16
189/16
209/16
209/16
209/16
G
315/16
315/16
315/16
321/2
321/2
321/2
L
1513/16
165/8
165/8
171/2
185/16
185/16
N
91/4
91/4
91/4
107/16
107/16
107/16
P
1213/16
1213/16
1213/16
14
14
14
Q
197/8
197/8
197/8
201/4
201/4
201/4
R
1911/16
1911/16
1911/16
235/8
235/8
235/8
T
471/16
503/8
503/8
471/16
503/8
503/8
S
153/16
153/16
153/16
163/4
163/4
163/4
U
51/4
51/4
51/4
67/8
67/8
67/8
D1
393/4
393/4
393/4
435/16
435/16
435/16
D2
447/8
447/8
447/8
487/16
487/16
487/16
E1
279/16
279/16
279/16
311/2
311/2
311/2
E2
3211/16
3211/16
3211/16
365/8
365/8
365/8
OUTPUT QDCMODEL
PUMP & MOTORSIZEø
6
8
WEIGHT LbACCESS HOLEPUMP
1294
1345
1404
1347
1398
1457
QDC
179
179
179
227
227
227
ø
150
200
e
241
298
f
279
343
t
25
29
n
8
8
h
22
22
mm
ø
6
8
e
91/2
113/4
f
11
131/2
t
1
11/8
n
8
8
h7/8
7/8
inch
PHASE
THREE
MODEL
150DLFU630
150DLFU637
150DLFU645
200DLFU630
200DLFU637
200DLFU645
kW
30
37
45
30
37
45
HP
40
50
60
40
50
60
LL150YU
LL150YU
LL150YU
LL200YU
LL200YU
LL200YU
A1
410
410
410
440
440
440
A2
360
360
360
420
420
420
B1
520
520
520
550
550
550
B2
410
410
410
470
470
470
F
471
471
471
522
522
522
G
795
795
795
825
825
825
L
402
423
423
444
465
465
N
235
235
235
265
265
265
P
325
325
325
355
355
355
Q
505
505
505
515
515
515
R
500
500
500
600
600
600
T
1195
1280
1280
1195
1280
1280
S
385
385
385
425
425
425
U
133
133
133
175
175
175
D1
1010
1010
1010
1100
1100
1100
D2
1140
1140
1140
1230
1230
1230
E1
700
700
700
800
800
800
E2
830
830
830
930
930
930
OUTPUT QDCMODEL
PUMP & MOTORSIZEø
150
200
WEIGHT kgACCESS HOLEPUMP
587
610
637
611
634
661
QDC
81
81
81
103
103
103
f
eø
(n) QTY - (h) HOLES
t
EBARA Fluid Handlingwww.pumpsebara.com 2-206(t) 803 327 5005 • (f) 803 327 5097 rev. 01/02
EBARA Submersible Sewage Pumps DLFU
Dimensions
Project: Model: Chk’d: Date:
Model DLFU with Quick Discharge Connector 250DLFU, 15 to 30HP
Bolt 4 – 13/16 (30)
29/16 (65) 471/4 (1200) 29/16 (65)
F
Submersible Cable
L . W. L.
1911/16 (500)
43/4 (120)
SGP (W) 3"
Bolt 2–5/8 x 13/16
(16x30)315
/16(1
00)
Guid
e p
ipe length
G
29 /16(6
5)
357 /16
(900
)
29 /16
(65)
Floor Frame
Manhole dimensions in
floor frame installation
Q
ø
259/16 (650)
317/8 (810)
U
T
279 /16
(700
)
133 /4
(350
)
175 /16
(440
)
77/8 (200)
711/16
(195)
171/8 (435)
13/16
(30)
235/8 (600)
153 /4
(400
)
97/16 (240)
L
Dimensions: inch
Dimensions: mm
Flange (ANSI 125 PSI F.F)
PHASE
THREE
MODEL
250DLFU611
250DLBFU615
250DLCFU615
250DLFU618
250DLFU622
kW
11
15
15
18.5
22
HP
15
20
20
25
30
Q.D.C.MODEL
LL250U
LL250U
LL250U
LL250U
LL250U
F
205/8
205/8
215/16
215/16
215/16
G
357/16
357/16
363/8
363/8
363/8
L
173/4
187/16
181/8
181/8
181/8
Q
149/16
149/16
153/8
153/8
153/8
T
471/2
4915/16
4911/16
511/4
511/4
U
25/16
25/16
113/16
113/16
113/16
PUMP
736
833
877
959
1030
Q.D.C.
331
331
331
331
331
OUTPUT PUMP & MOTORSIZEø
10
WEIGHT Lb
PHASE
THREE
MODEL
250DLFU611
250DLBFU615
250DLCFU615
250DLFU618
250DLFU622
kW
11
15
15
18.5
22
HP
15
20
20
25
30
Q.D.C.MODEL
LL250U
LL250U
LL250U
LL250U
LL250U
F
524
524
541
541
541
G
900
900
924
924
924
L
451
468
461
461
461
Q
370
370
390
390
390
T
1207
1269
1262
1302
1302
U
58
58
46
46
46
PUMP
334
378
398
435
467
Q.D.C.
150
150
150
150
150
OUTPUT PUMP & MOTORSIZEø
250
WEIGHT kg
ø
10
e
141/4
f
16
t
13/16
n
12
h
1
inch
mm
ø
250
e
362
f
406
t
30
n
12
h
25
f
eø
(n) QTY - (h) HOLES
t
G
EBARA Fluid Handlingwww.pumpsebara.com 2-207(t) 803 327 5005 • (f) 803 327 5097 rev. 01/02
EBARA Submersible Sewage Pumps DLFU
Dimensions
Project: Model: Chk’d: Date:
Model DLFU with Quick Discharge Connector 250DLFU, 40 TO 60HP300DLFU, 40 TO 60HP
Guide pipe support
Bolt 4 – 13/16 (30)
97/16 (240)
F E1
E2
L . W. L.
315/16
(100)
57/8 (150)
43/4 (120)
Bolt 2–5/8 x 13/16
(16x30)3 /16 (5
)
D1
D2
Floor plate
ø
B1
P
U
L
T
RS
Q
A1
61/8 (155)
N
23 /8(6
0)12
3 /8(3
15)
Dimensions: inch
Dimensions: mm
Flange (ANSI 125 PSI F.F)
PHASE
THREE
MODEL
250DLFU630
250DLFU637
250DLFU645
300DLFU630
300DLFU637
300DLFU645
kW
30
37
45
30
37
45
HP
40
50
60
40
50
60
LL250YU
LL250YU
LL250YU
LL300YU
LL300YU
LL300YU
A1
259/16
259/16
259/16
263/4
263/4
263/4
A2
1911/16
1911/16
1911/16
2213/16
2213/16
2213/16
B1
311/8
311/8
311/8
325/16
325/16
325/16
B2
221/16
221/16
221/16
253/16
253/16
253/16
F
2311/16
2311/16
2311/16
275/16
275/16
275/16
G
393/4
393/4
393/4
437/8
437/8
437/8
L
179/16
183/8
183/8
207/8
213/4
213/4
N
123/8
123/8
123/8
139/16
139/16
139/16
P
171/8
171/8
171/8
185/16
185/16
185/16
Q
25
25
25
273/8
273/8
273/8
R
279/16
279/16
279/16
311/2
311/2
311/2
T
483/8
513/4
513/4
509/16
537/8
537/8
S
175/16
175/16
175/16
215/8
215/8
215/8
U
83/4
83/4
83/4
915/16
915/16
915/16
D1
471/4
471/4
471/4
513/16
513/16
513/16
D2
531/8
531/8
531/8
571/16
571/16
571/16
E1
357/16
357/16
357/16
393/8
393/8
393/8
E2
415/16
415/16
415/16
451/4
451/4
451/4
OUTPUT QDCMODEL
PUMP & MOTORSIZEø
10
12
WEIGHT LbACCESS HOLEPUMP
1570
1631
1713
1733
1795
1876
QDC
344
344
344
450
450
450
ø
250
300
e
362
432
f
406
483
t
30
32
n
12
12
h
25
25
mm
ø
10
12
e
141/4
17
f
16
19
t
13/16
11/4
n
12
12
h
1
1
inch
PHASE
THREE
MODEL
250DLFU630
250DLFU637
250DLFU645
300DLFU630
300DLFU637
300DLFU645
kW
30
37
45
30
37
45
HP
40
50
60
40
50
60
LL250YU
LL250YU
LL250YU
LL300YU
LL300YU
LL300YU
A1
650
650
650
680
680
680
A2
500
500
500
580
580
580
B1
790
790
790
820
820
820
B2
560
560
560
640
640
640
F
602
602
602
693
693
693
G
1010
1010
1010
1115
1115
1115
L
446
467
467
531
552
552
N
315
315
315
345
345
345
P
435
435
435
465
465
465
Q
635
635
635
695
695
695
R
700
700
700
800
800
800
T
1229
1314
1314
1284
1369
1369
S
440
440
440
550
550
550
U
223
223
223
253
253
253
D1
1200
1200
1200
1300
1300
1300
D2
1350
1350
1350
1450
1450
1450
E1
900
900
900
1000
1000
1000
E2
1050
1050
1050
1150
1150
1150
OUTPUT QDC
MODEL
PUMP & MOTORSIZEø
250
300
WEIGHT kgACCESS HOLE
PUMP
712
740
777
786
814
851
QDC
156
156
156
204
204
204
f
eø
(n) QTY - (h) HOLES
t
19 /16(4
0)45 /16
(110
)
31 /8(8
0)
G
Flo
or F
ram
e
SGP (W) 3"
EBARA Fluid Handlingwww.pumpsebara.com 2-208(t) 803 327 5005 • (f) 803 327 5097 rev. 07/03
EBARA Submersible Sewage Pumps DLFU
Dimensions
Project: Model: Chk’d: Date:
Model DLFU with Quick Discharge Connector 300DLFU, 25 to 30HP
Bolt 4 – 13/16 (30)
13 /16(3
0)
215/16 (75) 471/4 (1200) 215/16 (75)
FSubmersible Cable
2213/16 (580)253/16 (640)
Bolt 2–5/8 x 13/16
(16x30)
Guid
e p
ipe length
G
215/16
(75)
357 /16
(900
)
215
/16(7
5)
Floor Frame
Manhole dimensions in
floor frame installation
331/16 (840)
311 /2
(800
)
215 /8
(550
)
1615/16
(430
)
77/8 (200)
97/16 (240)
153 /4
(400
)
315/16
(100
)
Dimensions: inch
Dimensions: mm
Flange (ANSI 125 PSI F.F)
PHASE
THREE
MODEL
300DLFU618
300DLFU622
kW
18.5
22
HP
25
30
Q.D.C.MODEL
LL300U
LL300U
G
3811/16
3811/16
F
231/8
231/8
T
553/8
553/8
U
45/16
45/16
L
225/16
225/16
Q
169/16
169/16
PUMP
1047
1107
Q.D.C.
331
331
OUTPUT PUMP & MOTORSIZEø
12
WEIGHT Lb
PHASE
THREE
MODEL
300DLFU618
300DLFU622
kW
18.5
22
HP
25
30
Q.D.C.MODEL
LL300U
LL300U
G
983
983
F
587
587
T
1407
1407
U
109
109
L
566
566
Q
420
420
PUMP
475
502
Q.D.C.
150
150
OUTPUT PUMP & MOTORSIZEø
300
WEIGHT kg
ø
12
e
17
f
19
t
11/4
n
12
h
1
inch
mm
ø
300
e
432
f
483
t
32
n
12
h
25
f
eø
(n) QTY - (h) HOLESt
263/4 (680)
43/4 (120)
L . W. L.
185/16 (465)
SGP (W) 3"
Q
T
711/16
(195)
ø
U
L
EBARA Fluid Handlingwww.pumpsebara.com 2-209(t) 803 327 5005 • (f) 803 327 5097 rev. 01/02
EBARA Submersible Sewage Pumps DLFU
Sectional View
Project: Model: Chk’d: Date:
2 to 5HP
Motors are purchased as a complete unit†: Recommended spare parts
PARTNO.
001
005
†012
†021
039
080
†111
†115-1
†115-2
†115-3
†115-4
†117
120-1
120-2
120-3
120-4
120-5
120-6
120-7
125
PART NAME
CASING
INTERMEDIATE CASING
SUCTION COVER
IMPELLER
KEY
BUSHING
MECHANICAL SEAL
O-RING
O-RING
O-RING
O-RING
GASKET
BOLT
BOLT
BOLT
BOLT
BOLT
BOLT
BOLT
BOLT
MATERIAL
CAST IRON
CAST IRON
CAST IRON
CAST IRON
420 STAINLESS
STEEL
—
RUBBER (NBR)
RUBBER (NBR)
RUBBER (NBR)
RUBBER (NBR)
304 STAINLESS
304 STAINLESS
304 STAINLESS
304 STAINLESS
304 STAINLESS
304 STAINLESS
304 STAINLESS
304 STAINLESS
ASTM, AISICODE
A48 Class 30
A48 Class 30
A48 Class 30
A48 Class 30
AISI420
A283 Grade D
AISI304
AISI304
AISI304
AISI304
AISI304
AISI304
AISI304
AISI304
NO. FOR1 UNIT
1
1
1
1
1
1
1 SET
1
1
1
2
1
4
8
4
4
3
4
2
1
PARTNO.
174
193-1
193-2
200
213
801
802
811-1
811-2
814
816
817
830
838
†849-1
†849-2
876
909
924
PART NAME
DISCHARGE ELBOW
PLUG
PLUG
LIFTING HANGER
AIR VENT VALVE
ROTOR
STATOR
POWER CABLE
CONTROL CABLE
MOTOR COVER
BRACKET
BRACKET
SHAFT
WASHER
BALL BEARING
BALL BEARING
MOTOR PROTECTOR
LEAKAGE DETECTOR
PACKING
MATERIAL
CAST IRON
304 STAINLESS
304 STAINLESS
STEEL
BRASS
—
—
—
—
CAST IRON
CAST IRON
CAST IRON
403 STAINLESS
304 STAINLESS
—
—
—
—
RUBBER (NBR)
ASTM, AISICODE
A48 Class 30
AISI304
AISI304
A283 Grade D
B36 No. 272
A48 Class 30
A48 Class 30
A48 Class 30
AISI403
AISI304
NO. FOR1 UNIT
1
1
1
1
1
1
1
1
1
1
1
1
1
2
1
1
3
1
2
8112
1207
1206
1205
1151
1202
1931
1204
1203
1152
1932
1153
1154
8492
8111
909
849
830
814
801
802
005
001 111
816
039012 125
174
117
021
080
838
817
924
876
1201
213
200
EBARA Fluid Handlingwww.pumpsebara.com 2-210(t) 803 327 5005 • (f) 803 327 5097 rev. 01/02
EBARA Submersible Sewage Pumps DLFU
Sectional View
Project: Model: Chk’d: Date:
71/2 to 10HP
9242
8382
1155
1206
1204
1151
1203
1202
1152
1931
8491
1932
1154
1153
8492
8111
8381
9241
8112
1207
909
802
801
816
039
021
114
111
001
005
125
213
012
117
876
814
817
830
PARTNO.
001
005
†012
†021
039
†111
†114
†115-1
†115-2
†115-3
†115-4
†115-5
†117
120-1
120-2
120-3
120-4
120-5
120-6
120-7
125
PART NAME
CASING
INTERMEDIATE CASING
SUCTION COVER
IMPELLER
KEY
MECHANICAL SEAL
OIL SEAL
O-RING
O-RING
O-RING
O-RING
O-RING
GASKET
BOLT
BOLT
BOLT
BOLT
BOLT
BOLT
BOLT
BOLT
MATERIAL
CAST IRON
CAST IRON
CAST IRON
CAST IRON
420 STAINLESS
—
RUBBER (NBR)
RUBBER (NBR)
RUBBER (NBR)
RUBBER (NBR)
RUBBER (NBR)
RUBBER (NBR)
304 STAINLESS
304 STAINLESS
304 STAINLESS
304 STAINLESS
304 STAINLESS
304 STAINLESS
304 STAINLESS
304 STAINLESS
ASTM, AISICODE
A48 Class 30
A48 Class 30
A48 Class 30
A48 Class 30
AISI420
AISI304
AISI304
AISI304
AISI304
AISI304
AISI304
AISI304
AISI304
NO. FOR1 UNIT
1
1
1
1
1
1 SET
1
1
1
1
1
1
1
4
8
4
6
3
4
2
1
PARTNO.
174
193-1
193-2
200
213
801
802
811-1
811-2
814
816
817
830
838-1
838-2
†849-1
†849-2
876
909
924-1
924-2
PART NAME
DISCHARGE ELBOW
PLUG
PLUG
LIFTING HANGER
AIR VENT VALVE
ROTOR
STATOR
POWER CABLE
CONTROL CABLE
MOTOR COVER
BRACKET
BRACKET
SHAFT
WASHER
WASHER
BALL BEARING
BALL BEARING
MOTOR PROTECTOR
LEAKAGE DETECTOR
PACKING
PACKING
MATERIAL
CAST IRON
304 STAINLESS
304 STAINLESS
STEEL
BRASS
—
—
—
—
CAST IRON
CAST IRON
CAST IRON
420J2 STAINLESS
304 STAINLESS
304 STAINLESS
—
—
—
—
RUBBER (NBR)
RUBBER (NBR)
ASTM, AISICODE
A48 Class 30
AISI304
AISI304
A283 Grade D
B36 No. 272
A48 Class 30
A48 Class 30
A48 Class 30
AISI420
AISI304
AISI304
NO. FOR1 UNIT
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
3
1
1
1
1201
174
200
1205
Motors are purchased as a complete unit†: Recommended spare parts
EBARA Fluid Handlingwww.pumpsebara.com 2-211(t) 803 327 5005 • (f) 803 327 5097 rev. 01/02
EBARA Submersible Sewage Pumps DLFU
Sectional View
Project: Model: Chk’d: Date:
15 to 30HP
9242
8382
1156
1207
8491
1206
1205
8162
1152
8161
1202
1931
1203
1151
1204
1153
1932
1155
1154
8492
8111
8381
9241
8112
1208
213
830
801
802
005
001
111114021039
012
125
117
876
814
817
909
PARTNO.
001
005
†012
†021
039
†111
†114
†115-1
†115-2
†115-3
†115-4
†115-5
†115-6
†117
120-1
120-2
120-3
120-4
120-5
120-6
120-7
120-8
125
PART NAME
CASING
INTERMEDIATE CASING
SUCTION COVER
IMPELLER
KEY
MECHANICAL SEAL
OIL SEAL
O-RING
O-RING
O-RING
O-RING
O-RING
O-RING
GASKET
BOLT
BOLT
BOLT
BOLT
BOLT
BOLT
BOLT
BOLT
BOLT
MATERIAL
CAST IRON
CAST IRON
CAST IRON
CAST IRON
420 STAINLESS
—
RUBBER (NBR)
RUBBER (NBR)
RUBBER (NBR)
RUBBER (NBR)
RUBBER (NBR)
RUBBER (NBR)
RUBBER (NBR)
304 STAINLESS
304 STAINLESS
304 STAINLESS
304 STAINLESS
304 STAINLESS
304 STAINLESS
304 STAINLESS
304 STAINLESS
304 STAINLESS
ASTM, AISICODE
A48 Class 30
A48 Class 30
A48 Class 30
A48 Class 30
AISI420
AISI304
AISI304
AISI304
AISI304
AISI304
AISI304
AISI304
AISI304
AISI304
NO. FOR1 UNIT
1
1
1
1
1
1 SET
1
1
1
1
1
1
1
1
4
8
4
6
6
3
6
2
1
PARTNO.
174
193-1
193-2
200
213
801
802
811-1
811-2
814
816-1
816-2
817
830
838-1
838-2
†849-1
†849-2
876
909
924-1
924-2
PART NAME
DISCHARGE ELBOW
PLUG
PLUG
LIFTING HANGER
AIR VENT VALVE
ROTOR
STATOR
POWER CABLE
CONTROL CABLE
MOTOR COVER
BRACKET
BRACKET
BRACKET
SHAFT
WASHER
WASHER
BALL BEARING
BALL BEARING
MOTOR PROTECTOR
LEAKAGE DETECTOR
PACKING
PACKING
MATERIAL
CAST IRON
304 STAINLESS
304 STAINLESS
STEEL
BRASS
—
—
—
—
CAST IRON
CAST IRON
CAST IRON
CAST IRON
420J2 STAINLESS
304 STAINLESS
304 STAINLESS
—
—
—
—
RUBBER (NBR)
RUBBER (NBR)
ASTM, AISICODE
A48 Class 30
AISI304
AISI304
A283 Grade D
B36 No. 272
A48 Class 30
A48 Class 30
A48 Class 30
A48 Class 30
AISI420
AISI304
AISI304
NO. FOR1 UNIT
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
3
1
1
1
1201
174
200
Motors are purchased as a complete unit†: Recommended spare parts
EBARA Fluid Handlingwww.pumpsebara.com 2-212(t) 803 327 5005 • (f) 803 327 5097 rev. 01/02
EBARA Submersible Sewage Pumps DLFU
Sectional View
Project: Model: Chk’d: Date:
40 to 60HP100DLFU
Motors are purchased as a complete unit†: Recommended spare parts*: Option for hard-piped installations
8381
1207
8491
1205
1153
1932
1152
1151
9241
8111
8382
1157
1155
8492
1206
1154
1204
8162
8161
1931
1203
1202
1201
9242
8112
1208
1156
817
876
814
830
909
213
200
174
117
167
801
802
111
005
114
001
021
039
080
125
107
PARTNO.
001
005
†021
039
080
†107
†111
†114
†115-1
†115-2
†115-3
†115-4
†115-5
†115-6
†115-7
†117
120-1
120-2
120-3
120-4
120-5
120-6
120-7
120-8
PART NAME
CASING
INTERMEDIATE CASING
IMPELLER
KEY
BUSHING
WEARING RING
MECHANICAL SEAL
OIL SEAL
O-RING
O-RING
O-RING
O-RING
O-RING
O-RING
O-RING
GASKET
BOLT
BOLT
BOLT
BOLT
BOLT
BOLT
BOLT
BOLT
MATERIAL
CAST IRON
CAST IRON
CAST IRON
420 STAINLESS
304 STAINLESS
304 STAINLESS
—
RUBBER (NBR)
RUBBER (NBR)
RUBBER (NBR)
RUBBER (NBR)
RUBBER (NBR)
RUBBER (NBR)
RUBBER (NBR)
RUBBER (NBR)
304 STAINLESS
304 STAINLESS
304 STAINLESS
304 STAINLESS
304 STAINLESS
304 STAINLESS
304 STAINLESS
304 STAINLESS
ASTM, AISICODE
A48 Class 30
A48 Class 30
A48 Class 30
AISI420
AISI 304
AISI 304
AISI304
AISI304
AISI304
AISI304
AISI304
AISI304
AISI304
AISI304
NO. FOR1 UNIT
1
1
1
1
1
1
1 SET
1
1
1
1
1
1
2
1
1
8
8
8
8
6
4
6
2
PARTNO.
125
*167
174
193-1
193-2
200
213
801
802
811-1
811-2
814
816-1
816-2
817
830
838-1
838-2
†849-1
†849-2
876
909
924-1
924-2
PART NAME
BOLT
BASE
DISCHARGE ELBOW
PLUG
PLUG
LIFTING HANGER
AIR VENT VALVE
ROTOR
STATOR
POWER CABLE
CONTROL CABLE
MOTOR COVER
BRACKET
BRACKET
BRACKET
SHAFT
WASHER
WASHER
BALL BEARING
BALL BEARING
MOTOR PROTECTOR
LEAKAGE DETECTOR
PACKING
PACKING
MATERIAL
304 STAINLESS
STEEL
CAST IRON
304 STAINLESS
304 STAINLESS
STEEL
BRASS
—
—
—
—
CAST IRON
CAST IRON
CAST IRON
CAST IRON
420J2 STAINLESS
304 STAINLESS
304 STAINLESS
—
—
—
—
RUBBER (NBR)
RUBBER (NBR)
ASTM, AISICODE
AISI304
A283 Grade D
A48 Class 30
AISI304
AISI304
A283 Grade D
B36 No. 272
A48 Class 30
A48 Class 30
A48 Class 30
A48 Class 30
AISI420
AISI304
AISI304
NO. FOR1 UNIT
1
1
1
1
1
1
1
1
1
2
1
1
1
1
1
1
2
1
1 SET
1
3
1
2
1
EBARA Fluid Handlingwww.pumpsebara.com 2-213(t) 803 327 5005 • (f) 803 327 5097 rev. 01/02
EBARA Submersible Sewage Pumps DLFU
Sectional View
Project: Model: Chk’d: Date:
40 to 60HP150DLFU200DLFU250DLFU300DLFU
Motors are purchased as a complete unit†: Recommended spare parts*: Option for hard-piped installations
8382
1157
1208
1206
1207
1204
8162
8161
1932
1203
1202
1201
9242
8112
1209
8111
9241
8381
1156
801
802
111
005
114
021
072
039
001
125
200817
876
814
830
909
8492
1155
8491
1154
1153
1205
174
280
117
1931
1151
1152 107 167
PARTNO.
001
005
†021
039
†072
†107
†111
†114
†115-1
†115-2
†115-3
†115-4
†115-5
†115-6
†115-7
†117
120-1
120-2
120-3
120-4
120-5
120-6
120-7
120-8
120-9
PART NAME
CASING
INTERMEDIATE CASING
IMPELLER
KEY
SIDE RING
WEARING RING
MECHANICAL SEAL
OIL SEAL
O-RING
O-RING
O-RING
O-RING
O-RING
O-RING
O-RING
GASKET
BOLT
BOLT
BOLT
BOLT
BOLT
BOLT
BOLT
BOLT
BOLT
MATERIAL
CAST IRON
CAST IRON
DUCTILE IRON
420 STAINLESS
CAST IRON
304 STAINLESS
—
RUBBER (NBR)
RUBBER (NBR)
RUBBER (NBR)
RUBBER (NBR)
RUBBER (NBR)
RUBBER (NBR)
RUBBER (NBR)
RUBBER (NBR)
304 STAINLESS
304 STAINLESS
304 STAINLESS
304 STAINLESS
304 STAINLESS
304 STAINLESS
304 STAINLESS
304 STAINLESS
304 STAINLESS
ASTM, AISICODE
A48 Class 30
A48 Class 30
A536 60-40-18
AISI420
A48 Class 30
AISI304
AISI304
AISI304
AISI304
AISI304
AISI304
AISI304
AISI304
AISI304
AISI304
NO. FOR1 UNIT
1
1
1
1
1
1
1 SET
1
1
1
1
1
1
2
1
13/4
4
8
4
8
8
4
6
2
PARTNO.
125
*167
174
193-1
193-2
200
280
801
802
811-1
811-2
814
816-1
816-2
817
830
838-1
838-2
†849-1
†849-2
876
909
924-1
924-2
PART NAME
BOLT
BASE
DISCHARGE ELBOW
PLUG
PLUG
LIFTING HANGER
ELBOW SUPPORT
ROTOR
STATOR
POWER CABLE
CONTROL CABLE
MOTOR COVER
BRACKET
BRACKET
BRACKET
SHAFT
WASHER
WASHER
BALL BEARING
BALL BEARING
MOTOR PROTECTOR
LEAKAGE DETECTOR
PACKING
PACKING
MATERIAL
304 STAINLESS
STEEL
CAST IRON
304 STAINLESS
304 STAINLESS
STEEL
STEEL
—
—
—
—
CAST IRON
CAST IRON
CAST IRON
CAST IRON
420J2 STAINLESS
304 STAINLESS
304 STAINLESS
—
—
—
—
RUBBER (NBR)
RUBBER (NBR)
ASTM, AISICODE
AISI304
A283 Grade D
A48 Class 30
AISI304
AISI304
A283 Grade D
A283 Grade D
A48 Class 30
A48 Class 30
A48 Class 30
A48 Class 30
AISI420
AISI304
AISI304
NO. FOR1 UNIT
1
1
1
1
1
1
2
1
1
2
1
1
1
1
1
1
2
1
1 SET
1
3
1
2
1
EBARA Fluid Handlingwww.pumpsebara.com 2-214(t) 803 327 5005 • (f) 803 327 5097 rev. 02/09