1
Side 2 350 Watt Power Supply FHJBLOWER System Blower Fan Spare Optional Accessories and Order Codes FHJ350WPS FHJTUPPMKIT PCIe* x16 Riser Card Hot-Swap Chassis Product Maintenance Kit AHJTPCIERISER A complete list of accessories and spares can be found at: www.intel.com/go/serverbuilder Front Panel Controls and Indicators (shown with bezel removed) A. NIC1 LED B. NIC2 LED C. Power LED D. System Fault LED E. HDD Activity LED F. USB 2.0 Port G. Power Button G C D B E F A 15 Install Rack Handles Install Rail Kit (optional) See the documentation that came with your selected rail kit for installation instructions. 18 Install Software • BIOS, Drivers, and Operating System Install A. Confirm BIOS Version: Look on the Server/System Management screen in the BIOS Setup Utility to determine the installed BIOS version. Compare this to the versions at: http://www.intel.com/p/en_US/support/highlights/server/s3420gp/ If new versions are available, update the BIOS on your server. See the User Guide on the Intel ® Server Deployment Toolkit CD for update instructions. B. Configure your RAID Controller: Use the instructions provided with the RAID controller. C. Install your Operating System: Use the instructions provided with the RAID controller and with the operating system. D. Install Operating System Drivers: With the operating system running, insert the Intel ® Server Deployment Toolkit CD. If using a Microsoft Windows* operating system, the installer will autorun and allow you to select the appropriate drivers to install. On other operating systems, browse the CD folders to locate and install the driver files. 16 Install Bezel (optional) 14 Install the Top Cover B Place cover onto chassis and slide forward. Install four screws at front. A A B 10 Install Hard Drives/Carriers Remove the drive carrier by pressing the green button and opening the lever. Then slide the carrier out. A Install the hard disk drive using the same four screws as shown. Make sure the connector end of the drive matches the backplane connector. C Remove the four screws securing the air baffle and remove the baffle. B Repeat these steps for each installed hard drive Hard Disk Drive Air Baffle B C A With the lever open, insert the hard disk drive assembly into the chassis opening and push until the locking lever engages. D Push in the lever to lock it into place. Note: System ships with SATA Hard Drives pre-cabled from the backplane to the server board. E CAUTION: If you install less than three drives or devices, empty drive bays must be occupied by carriers with baffles to maintain proper system cooling. D E 17 Finishing Up Before installing your operating system, you must finish your system installation and connect back panel I/O connectors and AC power. CAUTION: This unit must be operated with the TOP COVER installed to ensure proper cooling. 2. Connect your keyboard, mouse, video and other I/O cables/devices as shown. Then connect the AC power cord. 1. Make sure you have replaced the system cover. Network NIC2 USB 2, 3 Network NIC1 USB 0, 1 AC Power PCI Card Serial Port B Video Platform Cabling Diagram A Server Board B Power Supply C Blower Fan #1 D Blower Fan #2 E Front Panel Board F Hard Disk Drive Bays G Backplane H Optical Drive A E C D B F F F G A Power to Server Board (Main) B Power to Server Board (CPU) C Power to Backplane D Front Panel USB E Front Panel F Blower Fan #1 Power G Blower Fan #2 Power H A B C D E F G HDD 0 to Server Board SATA 0 I HDD 1 to Server Board SATA 1 J HDD 2 to Server Board SATA 2 K Optical Drive Data to Server Board SATA 3 L Link to backplane SPGIO M Optical Drive to Power Supply H I J H K CPU Server Board SATA Connector Legend Begin cable connections at the SATA-0 location. 5 2 1 0 4 3 M 13 Install Processor Air Duct Install processor air duct as shown. Use care to avoid pinching system cables. 12 Install PCIe Add-in Card Riser Assembly A Align the riser assembly with the server board riser socket. B Press the riser assembly into place and secure with two screws. A B Riser Socket 11 Install PCIe Add-in Card A Remove filler panel from the add-in card slot. B Insert add-in card until it seats in the riser connector. C Secure add-in card with screw as shown. CAUTION: Observe normal ESD precautions when installing add-in cards. Riser Connector Riser Assembly Supports one PCIe* card. Riser Card A C Add-in Card B 9 Install and Cable Optical Device (optional) A Remove the filler panel from the optical drive slot. B Insert the optical device into the slot as shown. C Secure the optical device with two screws as shown. D Connect SATA data cable to optical device and server board SATA connector as shown. E Connect the optical device power cable, routed as shown from the power supply. A B C SATA 3 Connector D E Intel ® Server Board S3420GP Component Layout Note: Not all components, jumpers and connectors are described in this diagram. Refer to your Server Board User’s Guide on the Intel ® Server Deployment Toolkit CD for additional information. A Intel ® Server Board S3420GPLX only. DIMM_A3 DIMM_A2 DIMM_A1 DIMM_B3 DIMM_B2 DIMM_B1 Slot 1, 32 Mbit/33MHz PCI Slot 6, PCI Express* Gen2 x8 (x16 Connector) Slot 5, PCI Express* Gen2 x8 (x8 Connector) Slot 4, PCI Express* Gen2 x4 (x8 Connector) Slot 2, PCI Express* Gen1 x1 (x4 Connector) Slot 3, PCI Express* Gen1 x4 (PCI Express* Gen2 Compliant) Intel RMM3 Connector Serial Port Internal USB SATA 5 SATA 2 SATA 1 SATA 0 Internal USB Floppy Connector Internal USB Front Panel Connector SATA 4 SATA 3 IPMB HSBP SAS Module Connector Internal USB SSD SATA_SGPIO SYS_FAN 3 SYS_FAN 1 SYS_FAN 2 Processor Socket CPU Fan Connector CMOS Battery Main Power Connector CPU Power Connector NIC2 USB2 USB3 NIC1 USB0 USB1 Serial Port A Video Note: Refer to the Technical Product Specification for Diagnostic LED decoder list. Diagnostic/ Status LEDs A A A J1F5 CMOS Clear J1F2 Password Clear J1F3 BIOS Recovery J1F1 ME Force Update J1A2 BMC Force Update SYS_FAN 4 A L

E73399-004 SR1630HGP QSUG back - Intel...Side 2 350 Watt Power Supply System Blower Fan Spare FHJBLOWER Optional Accessories and Order Codes FHJ350WPS FHJTUPPMKIT PCIe* x16 Riser Card

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: E73399-004 SR1630HGP QSUG back - Intel...Side 2 350 Watt Power Supply System Blower Fan Spare FHJBLOWER Optional Accessories and Order Codes FHJ350WPS FHJTUPPMKIT PCIe* x16 Riser Card

Side

2

350 Watt Power SupplyFHJBLOWERSystem Blower Fan Spare

Optional Accessories and Order CodesFHJ350WPS

FHJTUPPMKITPCIe* x16 Riser CardHot-Swap Chassis Product Maintenance Kit

AHJTPCIERISER

A complete list of accessories and spares can be found at: www.intel.com/go/serverbuilder

Front Panel Controls and Indicators(shown with bezel removed)

A. NIC1 LEDB. NIC2 LEDC. Power LEDD. System Fault LEDE. HDD Activity LEDF. USB 2.0 PortG. Power Button

G

C DB E

F

A

15 Install RackHandles

Install Rail Kit(optional)

See the documentation that camewith your selected rail kit forinstallation instructions.

18 Install Software • BIOS, Drivers, and Operating System Install

A. Confirm BIOS Version: Look on the Server/System Management screen in the BIOS Setup Utility to determine the installed BIOS version. Compare this to the versions at: http://www.intel.com/p/en_US/support/highlights/server/s3420gp/If new versions are available, update the BIOS on your server. See the User Guide on the Intel® Server Deployment Toolkit CD for update instructions.

B. Configure your RAID Controller: Use the instructions provided with the RAID controller.

C. Install your Operating System: Use the instructions provided with the RAID controller and with the operating system.

D. Install Operating System Drivers: With the operating system running, insert the Intel® Server Deployment Toolkit CD. If using a Microsoft Windows* operating system, the installer will autorun andallow you to select the appropriate drivers to install. On other operating systems, browse the CD folders tolocate and install the driver files.

16 Install Bezel (optional)

14 Install the Top Cover

B

Place cover onto chassis and slideforward.Install four screws at front.

A

A

B

10 Install Hard Drives/CarriersRemove the drive carrier by pressing the green buttonand opening the lever. Then slide the carrier out.

A

Install the hard disk drive using the same fourscrews as shown. Make sure the connectorend of the drive matches the backplane connector.

C

Remove the four screws securing the air baffleand remove the baffle.

B

Repeat these steps foreach installed hard drive

Hard DiskDrive

AirBaffle

B

C

AWith the lever open, insert the hard disk drive assembly into thechassis opening and push until the locking lever engages.

D

Push in the lever to lock it into place.

Note: System ships with SATA Hard Drives pre-cabledfrom the backplane to the server board.

E

CAUTION: If you install less than three drives or devices,empty drive bays must be occupied by carriers with bafflesto maintain proper system cooling.

D

E

17 Finishing Up

Before installing your operating system, you must finish your systeminstallation and connect back panel I/O connectors and AC power.

CAUTION: This unit must be operated with the TOP COVER installed to ensure proper cooling.

2. Connect your keyboard, mouse, video and other I/O cables/devices as shown. Then connect the AC power cord.

1. Make sure you have replaced the system cover.

Network

NIC2

USB 2, 3

Network

NIC1

USB 0, 1

AC Power

PCI Card

SerialPort B

Video

Platform Cabling Diagram

A Server Board

B Power Supply

C Blower Fan #1

D Blower Fan #2

E Front Panel Board

F Hard Disk Drive Bays

G Backplane

H Optical Drive

A

E

C D

B

F F F

G

A Power to Server Board (Main)

B Power to Server Board (CPU)

C Power to Backplane

D Front Panel USB

E Front Panel

F Blower Fan #1 Power

G Blower Fan #2 Power

H

A

B

C

D

E

F G

HDD 0 to Server Board SATA 0

I HDD 1 to Server Board SATA 1

J HDD 2 to Server Board SATA 2

K Optical Drive Data to Server Board SATA 3

L Link to backplane SPGIO

M Optical Drive to Power Supply

H I J

H

K

CPU

Server Board SATAConnector Legend

Begin cable connections at the SATA-0 location.

5

2

1

0

4

3

M

13 Install Processor Air Duct

Install processor air duct as shown.

Use care to avoid pinching system cables.

12 Install PCIe Add-in Card Riser Assembly

A Align the riser assemblywith the server boardriser socket.

B Press the riserassembly intoplace and securewith two screws.

A

B

RiserSocket

11 Install PCIe Add-in Card

A Remove filler panel from the add-in card slot.

B Insert add-in card until it seats in the riser connector.

C Secure add-in card with screw as shown.

CAUTION:Observe normal ESD precautions when installing add-in cards.

Riser Connector

Riser AssemblySupports onePCIe* card.

Riser CardAC

Add-in Card

B

9 Install and Cable Optical Device (optional)

A Remove the filler panel from the optical drive slot.

B Insert the optical device into the slot as shown.

C Secure the optical device with two screws as shown.

D Connect SATA data cable to optical device andserver board SATA connector as shown.

E Connect the optical devicepower cable, routed as shownfrom the power supply.

A

B

C SATA 3Connector

D

E

Intel® Server Board S3420GPComponent Layout

Note: Not all components, jumpers and connectors are described in this diagram. Refer to your Server Board User’s Guide on the Intel® Server Deployment Toolkit CD for additional information.

A Intel® Server Board S3420GPLX only.

DIM

M_A

3DI

MM

_A2

DIM

M_A

1DI

MM

_B3

DIM

M_B

2DI

MM

_B1

Slot

1, 3

2 M

bit/3

3MHz

PCI

Slot

6, P

CI E

xpre

ss*

Gen

2 x8

(x16

Con

nect

or)

Slot

5, P

CI E

xpre

ss*

Gen

2 x8

(x8

Conn

ecto

r)

Slot

4, P

CI E

xpre

ss*

Gen

2 x4

(x8

Conn

ecto

r)

Slot

2, P

CI E

xpre

ss*

G

en1

x1 (x

4 Co

nnec

tor)

Slot

3, P

CI E

xpre

ss*

Gen

1 x4

(PCI

Exp

ress

* Gen

2 Co

mpl

iant

)

Intel RMM3Connector

SerialPort

InternalUSB

SATA 5

SATA 2

SATA 1

SATA 0

Internal USBFloppy Connector

InternalUSB

Front PanelConnector

SATA 4

SATA 3 IPMB

HSBP SAS ModuleConnector

InternalUSB SSD

SATA_SGPIO

SYS_FAN 3SYS_FAN 1 SYS_FAN 2

Processor Socket

CPU FanConnector

CMOS Battery

Main PowerConnector

CPU PowerConnector

NIC2USB2USB3

NIC1USB0USB1

SerialPort A

Video

Note: Refer to the TechnicalProduct Specification for

Diagnostic LED decoder list.Diagnostic/

Status LEDs

A

A

A

J1F5

CMOSClear

J1F2

PasswordClear

J1F3

BIOSRecovery

J1F1

MEForce

Update

J1A2

BMCForce

UpdateSYS_FAN 4

A

L