30
HOUSING HYGIENE MEDICAL KITCHEN DINING COMMAND OFFICE FLOOR PLAN OPTIONS ENERGY EFFICIENT SHELTER SYSTEM PREMIER CAMP SOLUTIONS

E2S2 Floor Plans

Embed Size (px)

DESCRIPTION

This publications demonstrates the various plans, onfigurations and integration capability of Berg's new Energy Efficient Shelter System, the E2S2.

Citation preview

Page 1: E2S2 Floor Plans

HOUSING

HYGIENE

MEDICAL

KITCHEN

DINING

COMMAND

OFFICE FLOOR PLAN OPTIONS

ENERGY EFFICIENT SHELTER SYSTEM

PREMIER CAMP SOLUTIONS

Page 2: E2S2 Floor Plans

Contents

E2S2 Attributes ............................................................................................ 3

Billeting/Housing (5 Plans) ......................................................................4

Hygiene (1 Plan) ..........................................................................................10

Laundry (1 Plan) ..........................................................................................12

Kitchen | Dining (3 Plans) ........................................................................14

Medical (7 Plans) ........................................................................................18

Command/Executive | Office (2 Plans) ...............................................26

Endless Configurations ...........................................................................29

2

Page 3: E2S2 Floor Plans

5:20To Deploy

=

R-Values: R15 Ceiling/Floor Sidewalls: R17.

Base Container Weight: 7,550 lbs.

Deployment Time: 2 people | approx 10 min.

CSC Certified: Yes – water tight construction and C130 air transportable

Stacking: 9 High Closed | 2 High Deployed

Height: 8 ft. standard ISO, self-contained with no foundation, base or ground leveling required. Available in other ISO container heights including 8.5 ft.

Configurable: Scalable to meet the needs of varying camp requirements (50 to 1,000 person). Small camp stand alone and full camp integration

Floor Load Bearing: 67,200 lbs.

Attributes8 x 8 x 20 CSC Certified Cargo Container Shell

Stowed

Deployed

3

89” 7’ 5”

Page 4: E2S2 Floor Plans

Billeting/HousingPlan 14-Room | 8-Man

Plan 21-Room | 10-Man

Plan 31-Room | 16-Man

Plan 43-Room | 3-Man |Toliet

Plan 53-Room | 1-Man |Toliet

4

Page 5: E2S2 Floor Plans

Plan 1: 4-Room | 8-ManIsometric ViewOverhead View

ENTRANCE

ROOM 1ROOM 2

ROOM 4

ROOM 3

HALL

WAY

Left Side Right Side

• 4 Rooms• 32” Bunk Beds with Built-in Storage• Table & 2 Chairs• TV Stand

HOUSING PLAN 1 FEATURES:

5

Page 6: E2S2 Floor Plans

Plan 2: 1-Room | 10-ManIsometric ViewOverhead View

Left Side Right SideHOUSING PLAN 2 FEATURES:

ENTRANCE

TABLES & BENCHES

• 1 Room• (5) 32” Bunk Beds with Built-in Storage• 2 Tables• 2 Chairs

6

Page 7: E2S2 Floor Plans

Plan 3: 1-Room | 16-ManIsometric ViewOverhead View

Left Side Right Side

•1 Room• (8) 32” Bunk Beds with Built-in Storage• 2 Tables• 2 Chairs

HOUSING PLAN 3 FEATURES:

ENTRANCE

TABLES & BENCHES

7

Page 8: E2S2 Floor Plans

Plan 4: 3-Room | 2-Bed SuiteIsometric ViewOverhead View

Left Side Right SideHOUSING PLAN 4 FEATURES:

ENTRANCE

LIVING

KITCHEN

BEDROOM 1

BEDROOM 2

WASH ROOM

• 2 Bedrooms• Clothes Dresser• Kitchen with Stove, Refridgerator & Sink• Table with 4 Chairs

• Sofa• TV Stand• Bathroom with Shower, Washer & Dryer

8

Page 9: E2S2 Floor Plans

Plan 5: 1-Bed | Office SuiteIsometric ViewOverhead View

Left Side Right SideHOUSING PLAN 5 FEATURES:

• 1 Bedroom• Office/Study• Kitchen with Stove, Refridgerator & Sink• Table with 4 Chairs

• Sofa• TV Stand• Bathroom with Shower, Washer & Dryer

ENTRANCE

LIVING

KITCHEN

MASTER BEDROOM

OFFICE

WASH ROOM

9

Page 10: E2S2 Floor Plans

Hygiene CenterPlan 12-Room | Toilet | Shower | Laundry

10

Page 11: E2S2 Floor Plans

2-Room | Latrine | LaundryIsometric ViewOverhead View

Left Side Right SideHYGIENE CENTER PLAN 1 FEATURES:

• 5 Shower Stalls• 5 Toliets• 2 Urinals• LED Lighting

• Occupancy sensor• 2 Folding tables• Smoke/CO detector• Sinks with mirror

SHOWERLAUNDRY

LATRINELAUNDRY

11

Page 12: E2S2 Floor Plans

Laundry FacilityPlan 13-Room | Laundry

12

Page 13: E2S2 Floor Plans

Laundry | Utility Isometric ViewOverhead View

Left Side Right SideHYGIENE CENTER PLAN 1 FEATURES:

• 3 Dryers• 3 Washers• 6 Storage Cabinets• Utility Closet• Water Heater

• Utility Sink• 6 Folding Tables

13

3 WASHERS3 DRYERS

3 WASHERS3 DRYERS

FOLD

ING

TABL

ES

STRO

AGE C

ABIN

ETS STROAGE CABINETS

FOLDING TABLES

ENTRANCESINK WATER

HEATER

ENTRANCE

Page 14: E2S2 Floor Plans

Kitchen/DiningPlan 1Full Kitchen

Plan 240-Man Dining

Plan 3Combination Kitchen+Dining

14

Page 15: E2S2 Floor Plans

Plan 1: Full KitchenIsometric ViewOverhead View

Left Side Right SideKITCHEN PLAN FEATURES:

ENTRANCE

PREP TABLES

STOR

AGE S

HELV

ES

SINK REFRIDGERATOR

FRYERS SINKOVENS FLAT TOP GRILL

• 2 Sinks• 2 Prep Tables• Refridgerator

• Ovens• Flat Top Grill• Deep Fryers

15

Page 16: E2S2 Floor Plans

The Ideal Camp ShelterPlan 2: 40-Man Dining HallIsometric ViewOverhead View

Left Side Right SideDINING HALL PLAN FEATURES:

• (5) 8-Man Foldable Tables• Drink Station• Buffet Station• Food Warmers

ENTRANCE

DINING TABLES

WARMERSDRINK STATIONBUFFET

16

Page 17: E2S2 Floor Plans

Plan 3: Kitchen/Dining ComboIsometric ViewOverhead View

Left Side Right SideKITCHEN/DINING COMBO PLAN

• Complete E2S2 Dining Shelter•Complete E2S2 Kitrchen Shelter•Connecting Vestibule

DININGSHELTER

KITCHEN

17

Page 18: E2S2 Floor Plans

Medical FacilitiesPlan 1Examination | Surgery | Recovery

Plan 2Examination | Surgery | Recovery

Plan 3Examination | Surgery | Recovery

Plan 4Clinic | Beds | Offices

Plan 68-Bed Infirmary

Plan 5Diagnostic | Exam | Procedure

Plan 73-Room | 1-Man |Toliet

18

Page 19: E2S2 Floor Plans

Plan 1: Exam | Surgery | RecoveryIsometric ViewOverhead View

Left Side Right SideMEDICAL PLAN 1 FEATURES:

• 5 Rooms• Separate Waiting/Reception• 1 Hospital Bed• Surgical Table• Required Equipment• External Gas Cylinders

• Scrub Sink• Exam Table & Sink• Supply Storage• Instrument Storage• Desk & Chairs

ENTRANCE

WAITING

RECOVERY

EXAM

SURGERY

WASH ROOM

HALLWAY

External Gas Cylinders

19

Page 20: E2S2 Floor Plans

Plan 2: Exam | Surgery | RecoveryIsometric ViewOverhead View

Left Side Right SideMEDICAL PLAN 2 FEATURES:

ENTRANCE

ENTRANCE

WAITING

RECOVERY

EXAM

SURGERY

WASHROOM

External Gas Cylinders

• 4 Rooms• Wash Room• 1 Hospital Bed• Surgical Table• Required Equipment• External Gas Cylinders

• Scrub Sink• Exam Table & Sink• Supply Storage• Instrument Storage• Desk & Chairs

20

Page 21: E2S2 Floor Plans

Plan 3: Exam | Surgery | RecoveryIsometric ViewOverhead View

Left Side Right SideMEDICAL PLAN 3 FEATURES:

External Gas Cylinders

• Scrub Sink• Exam Table & Sink• Supply Storage• Instrument Storage• Desk & Chairs

ENTRANCE

RECEPTION

WAITING

RECOVERY

EXAM

SURGERY

WASH ROOM

• 4 Rooms• Wash Room• 1 Hospital Bed• Surgical Table• Required Equipment• External Gas Cylinders

• Scrub Sink• Exam Table & Sink• Supply Storage• Instrument Storage• Desk & Chairs• 2 Foldable Privacy Dividers

21

Page 22: E2S2 Floor Plans

Plan 4: Clinic | 2-Beds | 2-OfficesIsometric ViewOverhead View

Left Side Right SideMEDICAL PLAN 4 FEATURES:

External Gas Cylinders

ENTRANCE

RECEPTION

OFFICE

OFFICE

HALLWAY

PATIENT ROOM

PATIENT ROOM

WASH ROOM

• 5 Rooms• Wash Room• 2 Hospital Bed• 2 Offices with Workstations• Required Equipment

• External Gas Cylinders• 2 Scrub Sinks• 5 Desks• Supply Storage• Instrument Storage

22

Page 23: E2S2 Floor Plans

Plan 5: Exam | Diagnostic | ProcedureIsometric ViewOverhead View

Left Side Right SideMEDICAL PLAN 5 FEATURES:

External Gas Cylinders

• 5 Rooms• Wash Room• X-Ray Station• 2 Exam Rooms• Secure Storage Room

• External Gas Cylinders• Scrub Sink• Sink/Storage in Exam Rooms• Supply Storage• Required Equipment

ENTRANCE

EXAM

PROCEDURE

SECURESTORAGE

X-RAY STATION

EXAM WASH ROOM

23

Page 24: E2S2 Floor Plans

Plan 6: 8-Bed InfirmaryIsometric ViewOverhead View

Left Side Right SideMEDICAL PLAN 6 FEATURES:

ENTRANCE

PATIENT BEDS

• 1 Room• 8 Hospital Beds

24

Page 25: E2S2 Floor Plans

Plan 7: Clinic + Infirmary ComboIsometric ViewOverhead View

Left Side Right SideMEDICAL PLAN 7 FEATURES:

• Complete Clinic E2S2• Complete E2S2 Infirmary• Connecting Vestibule

25

Page 26: E2S2 Floor Plans

Command/Executive | OfficePlan 1Command/Executive

Plan 2Office/Administration

26

Page 27: E2S2 Floor Plans

Plan 1: Command/Executive CenterIsometric ViewOverhead View

Left Side Right SideCOMMAND/EXECUTIVE PLAN FEATURES:

ENTRANCE

STOR

AGE S

HELV

ES

CONF

EREN

CE TA

BLE

WOR

K ST

ATIO

NS

WASHROOMBREAK

AREA

• 4 Workstations• 2 Storage Cabinets• Sink• Small Refridgerator• Wash Room

27

Page 28: E2S2 Floor Plans

Plan 2: Office | AdministrationIsometric ViewOverhead View

Left Side Right SideOFFICE/ADMIN PLAN FEATURES:

ENTRANCE

OFFICE 1

OFFICE 2

WOR

K ST

ATIO

NS

WASHROOM

BREAK AREA

• 2 Offices• 3 Work Stations• Break Area with Sink/Refridgerator• Wash Room

28

Page 29: E2S2 Floor Plans

Endless Configurations

29

Page 30: E2S2 Floor Plans

Berg Company •16124 E Euclid Ave • Spokane, WA 99216 • O: 509.624.8921 • TF: 800.228.8277 • CAGE 4JKJ9 • DUNS 78-059-3856 • www.bergco.com