    TASCAM DR-071

    Contents

    Updates................................................................ 1

    New function........................................................ 1V1.02 addition ..........................................................................1

    Maintenance items .............................................. 1V1.01 changes ..........................................................................1

    Confirmation of firmware version ...................... 2

    Firmware update procedures .............................. 2

    DR-07Release Notes

    D01073620B

    Always use the most recent rmware for this device. Please

    visit the TASCAM web site at http://www.tascam.com to

    check for the latest rmware.

    Updates

    V1.01 changes

    A bug that caused the LINE input level to be fixedand prevented REC LEVELvolume changes when level

    control was set to AUTO has been fixed.

    A bug that caused Write Timeout to appearwhen recording an MP3 file at 48-kHz sampling

    frequency has been fixed.

    A bug that prevented recording from continuingcorrectly after using the track increment function when

    PRE REC was set to ON has been fixed.

    A bug that prevented recording an MP3 file fromcontinuing correctly after pausing and resuming

    recording has been fixed.

    Maintenance items

    V1.02 addition

    A new filter function has been added for the purpose

    of enhancing the sound quality of the mic inputs.

    This new function allows you to boost sound

    frequencies of 400 Hz and below. By using this

    function, you can record low frequencies with greater

    richness. The following changes have been made withthe addition of this function.

    The LCF icon (third from left) at the top of the

    Record Screen has been changed to FILT.

    New function

    On the I NPUT SETTINGscreen, the LOW CUT

    (LOW CUT FILTER) item has been changed to

    FILTER.

    On the INPUT SETTINGscreen, the FILTER

    item setting parameters now include OFF, +400Hz,

    -40Hz, -80Hzand -120Hz.

    NOTE

    The 40Hz, 80Hz and 120Hz still function as before,cutting frequencies below 40, 80 and 120 Hz, respectively.

  • 8/12/2019 e Dr-07 Rn Revb Web

    2/2

    2 TASCAM DR-07

    CAUTION

    When you updated the firmware, make sure that thebatteries have enough remaining power or use an optional

    AC adaptor (PS-P520). The program has been set so thatthe update will not be conducted if battery power isinsufficient.

    1 Download the most recent firmware from theTASCAM web site (http://www.tascam.com).

    2 Turn the units power ON and use the includedUSB cable to connect it with a computer. Thisunit will be recognized as an external drive

    (external storage device) by the computer.

    3 Copy the downloaded firmware to theUTILITY folder on the DR-07.

    4 After copying has completed, disconnect theunit from the computer following the correctprocedures, remove the USB cable. The unitautomatically restarts. Then, turn its powerOFF.

    5 While pressing and holding both the MENUand/keys, turn the unit power ON.

    The unit starts up in update mode, and the update le

    appears on the screen.

    NOTE

    This screen shows a list of the firmware update filesinside the UTILITY folder of the unit. Also, the screen

    shows the firmware copied at Step 3 above. No Update

    File appears if there is no update file in the UTILITYfolder.

    The screen shown is an example. The actual displaydiffers.

    CAUTION

    If this screen does not appear, turn the power OFF. Thenwhile pressing and holding both the MENU and /keys, turn the units power ON again. Continue to pressand hold the MENU and /keys firmly until this screenappears.

    6 Select the firmware (highlight the item) thenpress/. The following screen appears.

    The current version appears on the left and the updated

    version appears on the right.

    NOTE

    The screen shown is an example. The actual displaydiffers.

    7 Press the/key to start the update.

    8 When the update is complete, the power turnsOFF automatically. Turn the power ON again.

    9 Follow the Confirmation of firmware versioninstructions above to check that the SystemVers. is now the most recent version of thefirmware.

    This completes the procedure for updating this unit.

    10 Connect to a computer with USB and deletethe firmware update from the units UTILITYfolder.

    Firmware update procedures

    Confirmation of firmware version

    Conrm the rmware version of your DR-07 before

    conducting a rmware update.

    1 Turn the units power ON.

    2 Press the MENUkey to open the MENUscreen,select "INFORMATION" and press the /key.

    3 Turn the wheel right to confirm the "SystemVer." displayed at the bottom.

    You do not need to update the units rmware if the version

    shown is the same as or newer than the version that you

    intend to use for the update.