47
E-COM-SINGLE software Operating manual Edition 05.2016 Printing 06.2016 Language EN [Original] For software from 1.02 For Pneumatic seeding machines Reference number A139434440

E-COM-SINGLE software

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: E-COM-SINGLE software

E-COM-SINGLE software

Operating manualEdition 05.2016Printing 06.2016Language EN [Original]For software from 1.02For Pneumatic seeding machinesReference number A139434440

Page 2: E-COM-SINGLE software

E-COM-SINGLE software

Identification of the machineIn order for your dealer to assist you as fast as possible, you will need to provide some information about yourmachine.Please enter the details here.

Designation

Working width

Weight

Machine number

Accessories

Address of dealer

Address of manufacturer Kverneland Group Soest GmbHCoesterweg 42D-59494 SoestGermany

Tel. +49 (0) 2921/974-0

Copyright by Kverneland Group Soest GmbH, Germany. Reproduction, transfer to other media, translation or the use of extracts or parts of thismanual without the explicit permission of Kverneland, is not permitted. All rights reserved. The contents of this operating manual are subject tochange without notice. The right to technical revision is reserved.

Page 3: E-COM-SINGLE software

Table of contents

3

Table of contents

Preliminary information .................................. 4Safety 4Instruction 4Other applicable documents 4Symbols 5

Opening screen ...............................................6

Information screen ..........................................7Information area at the top 8Information area at the bottom 9Information area at the centre 9Keys 10

Basic settings ................................................13

“Machine”.......................................................14Keys 14Symbols 14

“Sensors”.......................................................16Keys 16Symbols 17

“RPM reduction”............................................19Keys 19

“PIN entry” .....................................................20Keys 20

Calibration test ..............................................21Keys 21Symbols 23Performing a calibration test 26

Tramlines........................................................30Keys 30Symbols 30

Configuration of the shut-off valves............31Keys 31

ISOBUS settings ............................................32Page 1 32Keys 32Page 2 33Page 3 33Page 4 35

Test menu.......................................................36Page 1: Information 36Page 2:Test 36Page 3:Test 37Page 4: Test 38Page 5: Information 40Task processing 41

ECU screen .................................................... 42

Storage ........................................................... 43Storage 43

Eliminating faults .......................................... 44

Index ............................................................... 47

Page 4: E-COM-SINGLE software

Preliminary information

Preliminary informationTarget group This operating manual is intended for trained farmers and individualswho are otherwise qualified to perform agricultural activities and whohave received instruction in the operation of this software.

Safety Study the contents of this operating manual carefully, which are rele-vant for your activity, before initial operation or assembly of the ma-chine. Always read through the safety instructions in the chapter“Safety” and observe the warning information in the individual chap-ters. In this way, you will achieve optimum work results and opera-tional safety.

For the employer Staff must be instructed in the safe handling of the software before theinitial commissioning. Untrained or unauthorised persons are not per-mitted to use the software.

The following are included in this training:

• Checking that staff possess the necessary requirements for safely handling the software.

• Handing out the operating manual and the other relevant and ap-plicable documents or an intensive course of training which, in par-ticular, includes the safe handling of the software.

Regular instruction ses-sions

Instruct your staff regularly, but at least once year, concerning the ba-sic procedural measures for safely handling the software.

Instruction You will receive training from your dealer concerning using the con-trols and safe operation of the software. Initial operation without firstreceiving training is not permitted.

Other applicable documents

In addition to the operating manual, other documents also form an in-tegral part of the machine:

Operating manual of the seeding machine Integral part of the delivery of the seeding machine

Operating manual for the terminal For example, IsoMatch Tellus

“GEOcontrol” operating manual Integral part of the delivery of the software

“TaskControl” operating manual Integral part of the delivery of the software

4

Page 5: E-COM-SINGLE software

Preliminary information

Symbols In order to make this manual clear and easy to read, we have usedvarious symbols. They are explained below:

• A bullet point accompanies each item in a list

A triangle indicates operating functions which must be performed

→ An arrow indicates cross-references to other text passages

[+] A plus sign indicates an accessory that is not included in the stand-ard version.

Pictograms We have also used pictograms to help you find instructions morequickly:

This symbol indicates information, tips and notes on operation.

This symbol indicates tips for assembly or adjustment work.

This symbol indicates examples that assist a better understanding ofthe instructions.

Parts in the text which refer to individual machines or to conditionshave a coloured background. After the coloured section, the text thenagain applies to all conditions and machines. For example:

Before folding out only:

Actuate the control unit

The warning triangle indicates warning information. Failure to ob-serve these safety instructions can result in:

• Moderate to serious injury

• Fatal injury

You will find the warning information associated with individual op-erations, where it is important to observe the warning informationbefore these operations are carried out.

This sign indicates important instructions regarding the machine.Failure to observe these safety instructions can result in:

• Serious faults in the correct operation of the machine

• Damage to the machine

Release the locking mechanism for transport

5

Page 6: E-COM-SINGLE software

Opening screen

Opening screen The system is ready to operate after being connected up and can beswitched on.

Switch on the terminal

→ Operating manual for the terminal

The system performs a short self-test. You will then see the informa-

tion screen.

Apart from the opening screen and the information screen there is alsoan ECU screen available. The inputs are described in a separate op-erating manual.→ “IsoMatch Tellus” operating manual

You can see symbols for selection in the opening screen.

To the information screen→ Chapter »Information screen«, page 7

To the ECU screen→ Operating manual for “IsoMatch Tellus” or another ISOBUS-com-

patible screen

Back to the last function

Press the symbol

To the selection screen

Press the symbol

Depending on the equipment fitted, you can switch between the appli-cations shown.

6

Page 7: E-COM-SINGLE software

Information screen

Information screen The information screen displays all of the most important values dur-ing seeding work.

Information area at the topYou can read off all of the current values during seeding work in theinformation area at the top. In addition, the quantity of seed or fertiliserapplied for one metering device is displayed. The values change whenactivating an increased or decreased amount during seeding.You can change the application amount of seed or fertiliser also by in-putting the quantity directly. Exceeding or not reaching the amountfrom the calibration test by more than 50% is not possible.

Information area at the bottomThe information area at the bottom is used to display the current statusof the fan and the area being worked.

Information area at the centreThe machine is shown in the information area at the centre. Informa-tion on the metering device will be displayed.

The meaning of the symbols will be described on the next pages. Youcan also go directly into the menu “Basic settings” and check and alterentries there.→ Section »Basic settings«, page 13

Top

Centre

Bottom

Information area:

7

Page 8: E-COM-SINGLE software

Information screen

Information area at the top

Symbols Speed in km/hour

Information about the tramlinesOnly visible if tramlines are activated.

Example:1 : 41 = Current pass4 = Total number of passes in a rhythm

Amount of seed [kg/ha] or the number of grains per m².The pre-set amount of seed is displayed.

Selected seed and number of calibration test

8

Page 9: E-COM-SINGLE software

Information screen

Information area at the bottom

Symbols Cultivated area, in haThe number over “ha” specifies the active task from the menu “Task”.

Fan speed in revolutions per minuteThe current value is displayed.

[+] Working lights on

Information area at the centre

Symbols Metering device in operation. Display for the right- and left-hand me-tering device.

9

Page 10: E-COM-SINGLE software

Information screen

Keys

Page 1Turn to the next page

Scroll to the previous pages

Track markerActivate the track marker on the left side

Activate track marker on right side

To fold the track marker the machine must be folded out and must bein work position.

To perform seeding work, preselect the track marker which has to be opened out first. The symbol flashes.

Actuate the control unit on the tractor. The track marker is folded out.

The flashing symbol indicates that the hydraulic valve is active. Lift outthe machine at the end of the field and actuate the control unit for thetrack markers. Lifting out the machine will cause the second trackmarker to be pre-selected automatically and lowered when the controlunit is actuated.

Depending on the type of machine, passes for setting up tramlines au-tomatically will only continue to be counted if the track marker was ac-tuated and the machine was lifted.

The second track marker is activated after a delay of 1 second.

Switching off the metering device

Activate or deactivate the tramline control systemIf the tramline control system is deactivated, the current pass is con-tinued.

When the tramline control system is deactivated, the symbol for acti-vating or deactivating the tramline control system flashes and a redcross appears in the information area next to the display for the tram-line.

0 : 0

10

Page 11: E-COM-SINGLE software

Information screen

Only the current track marker is used. The second track marker re-mains folded. For information purposes, the flashing symbol appearsin the information area.

Start the metering device manuallyThe speed adopted is the speed preselected on the “Basic settings”menu, irrespective of the actual speed of the tractor. Manual startingremains active for 15 seconds or until the actual speed exceeds thepreselected speed.

“Obstacle” keyThe folded out track marker is activated for folding in. The tramline se-quence is not counted any further until the key is pressed again.

11

Page 12: E-COM-SINGLE software

Information screen

Page 2Turn to the next page

• Task processing

→ Chapter »Task processing«, page 41

When TaskControl is activated, the symbol is not visible.

Increase application rate by a defined percentageExceeding the amount from the calibration test by more than 50% isnot possible.

Decrease application rate by a defined percentageNot reaching the amount from the calibration test by more than 50%is not possible.

Reset the application rate to the normal value

Alter settings for the application rate(The key allocation changes)

Switch the machine's work light and hopper interior lighting on or off

Alter settings for the tramline rhythm(The key allocation changes)

Current pass +1

Current pass -1

Set current pass to first pass. The rhythm begins afresh.

• Basic settings

→ Chapter »Basic settings«, page 13

12

Page 13: E-COM-SINGLE software

Basic settings

Basic settings Basic settings refer to machine data which is important for controllingfunctions or triggering alarms. The basic settings are spread over anumber of sections.

To the next page

“Configuration”1. “Machine”→ Chapter »“Machine”«, page 142. “Sensors”→ Chapter »“Sensors”«, page 163. “RPM reduction”→ Chapter »“RPM reduction”«, page 194. “PIN entry”→ Chapter »“PIN entry”«, page 20

• Calibration test

→ Chapter »Calibration test«, page 21

Restore factory settingsAll inputs are reset to the stored factory setting.

• Tramlines

→ Chapter »Tramlines«, page 30

• ISOBUS settings

→ Chapter »ISOBUS settings«, page 32

• Checking

→ Chapter »Test menu«, page 36

ISOBUSconform

13

Page 14: E-COM-SINGLE software

“Machine”

“Machine”

Keys To the information screen

To the next page

To the previous page

SymbolsNumber of pulses from the radar sensor over 100 m. The pre-set valueis 18500 pulses over 100 metres.

Recommendation: You can determine this value through calibration.This procedure is more accurate and is adapted to the current soilconditions:

Exactly measure off 100 metres on the field

Move the machine to its work position

Activate “Start” and drive the measured 100 metres

Activate “Stop”

The number of pulses will be indicated.

Confirm the value with “OK”

Number of pulses/100 m; start recalibration with “START”

Fan speed – Store the value with “SET”

Increased or decreased amount

Metering device usage

Working width of the machine in metres

Number of seed coulters

m

14

Page 15: E-COM-SINGLE software

“Machine”

The fan speed can be saved here as a nominal value between3000 rpm and 5000 rpm. To do so, run the fan at the desired speed.The actual value is displayed in blue in the centre.

Once the value is reached, store it with “SET”

The bottom and top limits for an alarm are then calculated automati-cally.

Enter the desired percentage steps for the increased and decreasedamounts during seeding. The amount of seed is increased or de-creased by this percentage in the information screen using the appro-priate keys.

→ Section »Keys«, page 10

Displays the metering device used

15

Page 16: E-COM-SINGLE software

“Sensors”

“Sensors”

Activating or deactivating:

Keys To the information screen

To the next page

To the previous page

Activate or deactivate the alarm if the target speed is not reached or is exceeded

Select the type of speed sensor

Select type of start-stop sensor

Activates or deactivates the audible signal when the metering device motors are started

Select the type of tramline switchover

Activate or deactivate the hopper low level sensor

Activates or deactivates the alarm if the flap on the metering device is open

Activate or deactivate the sensor on the fan

Activate or deactivate the sensor for monitoring the metering roller

Activate = Tick in box

Deactivate = No tick in box

16

Page 17: E-COM-SINGLE software

“Sensors”

Symbols The alarm is triggered if the speed for the exact application of seed istoo low or too high. The alarm can be deactivated. We recommendthat the alarm is always switched on.

The type of speed sensor can be set here:

The type of start-stop sensor can be set here:

The type of sensor to be used for incorporating tramlines can be sethere:

• ISOBUS drive wheel

Wheel sensor on the tractor via ISO 11783 in-terface

• ISOBUS radar Radar sensor on the tractor

• Manual Here you can enter a speed which is inde-pendent of the sensors, e.g. if the speed sen-sor is defective but you wish to continue sow-ing. Drive at the entered speed then.

• GPS J1939 GPS aerial

• Radar Radar sensor on the machine

• NMEA 2000 NMEA 2000 signal from the tractor

Enter start and stop manually

Starting and stopping are controlledautomatically by sensors on the seed-ing machine

Starting and stopping are controlledautomatically by sensors on the trac-tor

The work position of the seeding ma-chine controls how tramlines are in-corporated in the field

Sensors on the track marker and thework position of the seeding machinecontrol how tramlines are incorpo-rated in the field

Sensors on the tractor control howtramlines are incorporated in the field

ISO11783

ISO11783

17

Page 18: E-COM-SINGLE software

“Sensors”

Activate or deactivate the sensor on the fan

Machines with radar sensor:

Activate or deactivate the sensor for monitoring the metering roller

Activate or deactivate the hopper low level sensor

Activates or deactivates the alarm if the flap on the metering device isopen. In the event that the alarm is activated, you will receive a mes-sage if the flap on the metering device is open during sowing.

Activate or deactivate the audible alarmWhen the alarm is activated, you will receive an audible signal whenthe metering device starts.

Activate the fan sensorOn machines with a radar sensor, the fan sensor must be activated.If the fan sensor is deactivated, the metering device motor can startunexpectedly when the machine is stationary. Persons who carryout work on the metering device may be injured.

Check whether the fan sensor is activated. If not, activate the fan sensor.

18

Page 19: E-COM-SINGLE software

“RPM reduction”

“RPM reduction”

Keys To the information screen

To the next page

To the previous page

Automatic reduction in the amount of seed when creating tramlines. When creating tramlines, the seed is distributed from the blocked seed coulters to the remaining seed coulters. The increased amount of seed can be compensated for on the metering de-vice by reducing the amount of seed. Activate or deactivate.

Minimum speed for metering seed or fertiliser. This speed is used to calculate the me-tering quantity, irrespective of the actual speed of the tractor. Activate using the key on the information screen. Manual starting remains active for 15 seconds or until the actual speed exceeds the preselected speed.

Number of shut-off valves which are closed when creating tramlines for the left or right track. Enter the number.

No function

19

Page 20: E-COM-SINGLE software

“PIN entry”

“PIN entry”

Keys To the information screen

To the next page

To the previous page

PIN-code entry for the service technician. Subsequent pages show special information about motors and sensors. This information is intended for the service technician.

20

Page 21: E-COM-SINGLE software

Calibration test

Calibration test A calibration test must be performed for each seed or type of fertiliser.The number of the calibration test active in each case flashes.

Do you wish to spread a seed type which is not in the software's se-lection list or mixture of seed?→ Chapter »Calibration test«, section »Special seed«, page 27

KeysTo the information screen→ Chapter »Opening screen«, page 6

To the next calibration test

To the previous calibration test

Start the calibration test

Start the test run

Accept the calibration testOnly possible after successful calibration test. The values are then ac-cepted as the basis for the seeding work.

Date

Calibration test performed (green) or still open (red)

Select the seed type

Free text field for entering comments

Desired application rate [kg/ha] or [grains/m2]

Enter the thousand grain weight of the seed in grams

Enter the germination capacity of the seed in percent

Desired driving speed

Information on making settings on the metering device

Minimum and maximum driving speed

Input [kg/ha] or [grains/m2]

21

Page 22: E-COM-SINGLE software

Calibration test

Call up the saved input values.

Save the input values.

22

Page 23: E-COM-SINGLE software

Calibration test

SymbolsYou can enter comments on the calibration test here. Enter text usingthe keyboard displayed on the screen.

Calibration test not yet performed

Calibration test performed successfully

Enter the desired application rate in kg/haWhen doing this ensure that the correct seed is selected.

Enter the desired application rate in grains/m2.When doing this ensure that the correct seed is selected.

Enter the thousand grain weight of the seed in grams

Enter the germination capacity of the seed in percent

Enter the desired “normal” driving speedThe normal driving speed is roughly 3 km/h less than the maximumspeed shown in the seeding machine operating manual. The minimumand maximum speeds are calculated from the normal driving speed.

m

m

1000

23

Page 24: E-COM-SINGLE software

Calibration test

Information on making settings on the metering device. You will re-ceive the correct information automatically from the software:

• Number of the metering roller that is to be used

• Information about whether or not the auxiliary plate should be in-stalled in the metering device

Make the settings on the metering device according to the infor-mation provided by the software.

Number of the metering roller. The number can be found on the sideof the metering roller.

The metering roller is selected via the software. Install the meteringroller specified according to the calibration test in the metering device.

Depending on the seed and application rate, it may be necessary to fitthe auxiliary plate. The auxiliary plate prevents the drive motor frombeing overloaded.→ Seeding machine operating manual

Number Metering roller

1

2

3

4

5

1...5

24

Page 25: E-COM-SINGLE software

Calibration test

After calibration, weigh the seed and enter the value in kg

Minimum and maximum driving speed [km/h]If the limits are nor reached or exceeded, an alarm is triggered. Theinformation provided relates to the driving speed theoretically sup-ported by the metering device. Out on the field, the maximum drivingspeed is determined by other factors. The type of the seed, nature ofthe soil, equipment of the seeding machine and the desired accuracyof seed placement, for example, are such factors.

Several calibration tests can be generated. If the seed is the sameseed and has the same properties, the values of a calibration test al-ready performed can be used.However, if, for example, the TGW (thousand grain weight) of the seeddiffers, we recommend that a new calibration test be performed.

25

Page 26: E-COM-SINGLE software

Calibration test

Performing a cali-bration test

You can start the calibration test via the terminal or directly on the me-tering device.

Input The following values must be entered first of all:

The following settings are calculated and must be set on the meteringdevice:

Place a catch pan under the metering device or devices

Do not start the tractorDuring the calibration test, persons may be in the machine's hazardarea. Do not start the tractor and leave the tractor's handbrake ap-plied.Anyone located in the hazard area of the machine may be seriouslyor fatally injured by moving machine parts or by movement of themachine itself.

Input Example

Seed Wheat

Application rate [kg/ha] 200

Desired driving speed [km/h] 6

Setting Example

Select the metering roller as spec-ified and install in the metering de-

vice

Metering roller 2

Auxiliary plate Install

26

Page 27: E-COM-SINGLE software

Calibration test

Special seed Proceed as follows if you wish to spread a seed type which is not inthe software's selection list or a mixture of seed:

• Select a seed type which is most similar to the size and nature of your seed

Performing a calibration test

Start the test run

The software cannot compensate for differences between the desiredapplication rate and the actual application rate because the propertiesof the special seed are unknown. It is therefore not possible to achieveexactly the desired application rate.

You can increase or decrease the application rate manually. Use thesettings for increased amount or decreased amount to do this.→ Chapter »Information screen«, Chapter »Page 2«, page 12

Mixture If you wish to spread a mixture of two or more seed types, proceed asfollows:

• Start with the largest seed and select the seed from the selection list in the software

Performing a calibration test

Start the test run

The more the seed types differ, the greater the difference will be be-tween the desired application rate and the actual application rate. Thedistribution of the mixture changes as soon as filling starts and later onin the seed hopper, for example due to vibrations. This separates theseed types. It is therefore not possible to achieve exactly the desiredapplication rate, particularly where the mixture contains smaller seedtypes.

You can increase or decrease the application rate manually. Use thesettings for increased amount or decreased amount to do this.→ Chapter »Information screen«, Chapter »Page 2«, page 12

Manual starting You can start the metering device manually. A key is located directlyon the metering device.

Press the key. The metering device starts.

Pause Press the key again

End pause Press the key again

27

Page 28: E-COM-SINGLE software

Calibration test

Filling Start the calibration test

The cell wheel of the metering device is now filled. To do so there mustbe sufficient seed in the seed hopper.

Abort filling

Start filling or start manually→ Chapter »Calibration test«, section »Manual starting«, page 27

Start filling the cell wheel

Empty the catch pan and put it back under the metering device

A calibration is performed after filling.

Abort calibration

Start calibration or start manually→ Chapter »Calibration test«, section »Manual starting«, page 27

PausePress again: Continue calibration

Start calibration

28

Page 29: E-COM-SINGLE software

Calibration test

After calibration, the seed from the catch pan must be weighed.

Enter the weighing result in kg

The amount weighed can deviate from the desired amount. For exam-ple, if 200 kg/ha of wheat are to be applied, but the amount weighedat 0.10 ha corresponds to only 18 kg instead of the expected 20 kg,this is then not an error. Please enter the result of the weighing fromthe calibration. Not until the test run is a working run simulated with theset values. Therefore always perform a test run.

After the weighing result has been entered, “OK” appears on the dis-play.When confirmed, the weighing result is converted to the driving speed.

Confirm the “OK” on the display

Start the test run A test run is advisable, especially if a calibration test with a differentseed quality is to be adopted.

Abort the test run

Start test run or start manually→ Chapter »Calibration test«, section »Manual starting«, page 27

PausePress again: Continue test run

Place a catch pan under the metering device or devices

Start test run or start manually

Weigh the seed from the catch pan and compare it with the setpoint value

If there are any deviations, perform a new calibration test

29

Page 30: E-COM-SINGLE software

Tramlines

Tramlines Tramlines are laid down for spraying/fertilising units such as fieldsprayers or fertiliser spreaders.

Keys Pressing the key will take you to the information screen

Pressing the key will take you to the shut-off valve configuration for thetramlines

Symbols Working width of the spraying/fertilising unit in metresFor example, field sprayers or fertiliser spreaders

Beginning the seeding work at the left side of the field

Beginning the seeding work at the right side of the field

Is only displayed if just one selection is possibleSetting up symmetrical tramlinesBoth marks will be created during one pass.

Is only displayed if just one selection is possibleSetting up asymmetrical tramlinesJust one mark will be set up in one pass.

Allows tramline incorporation to be activated or deactivated

Display is green if tramline rhythm is possible, otherwise red

Spraying/fertilising unit working width

Begin at the right or the left at the edge of the field

Laying of the tramlines symmetrically or asymmetrically

30

Page 31: E-COM-SINGLE software

Configuration of the shut-off valves

Configuration of the shut-off valves Calls up the configuration of the shut-off valves

KeysTo the information screen

To the tramline menu

Spraying/fertilising unit track width

Spraying/fertilising unit tyre width

Number of coulters on which shut-off valves need to be fitted for the corresponding tramline rhythm.

31

Page 32: E-COM-SINGLE software

ISOBUS settings

ISOBUS settings Settings can be made to the screen and GEOcontrol here.

Page 1

Keys To the information screen→ Chapter »Opening screen«, page 6

To the next page

Identification of the screen

Replace the terminals

Replace the contents of the screen:

ISOBUSconform

?1 2

Select screen

Waiting time for information from connected devices. Cannot be adjusted.

12

Current screen

Screen Swap with screen

Top Bottom

Left Right

?1 2

12

32

Page 33: E-COM-SINGLE software

ISOBUS settings

Page 2

Page 3

Keys To the information screen→ Chapter »Opening screen«, page 6

To the previous page

To the next page

Select TaskControl

Task management via TaskControl

Use the information from area maps for distributing seed

Select automatic deactivation of sowing units

Display of the software version used by TaskControl

Input “Functional instance” number from the terminal. The number must be identi-cal to the number of the terminal on which the software will be displayed

Enter licence key

Lateral offset to the tractor centre

“T-ON”: The metering device is switched on in advance

Distance from the connection point on the tractor to the centre of the seed coulters

“T-OFF”: The metering device is switched off in advance

Type of attached machine

33

Page 34: E-COM-SINGLE software

ISOBUS settings

SymbolsAttached seeding machine

Trailed seeding machine

“T-ON”: The seeding machine is to apply seed starting from a particu-lar point, for example after leaving the headland.To do this, the metering device must already be delivering seed beforethat point is reached. A few seconds are required for transporting theseed from the metering device to the coulters.Specify the time here in seconds when the metering device shouldstart to deliver seed before the point is reached. You will thereby en-sure that the seed has arrived at the coulters when the point isreached. The “T-ON” value must be greater than the “T-OFF” value.

“T-OFF”: The seeding machine is to apply no seed starting from a par-ticular point, for example when reaching the headland.To do this, the metering device must already stop delivering seed be-fore that point is reached. A few seconds are required for transportingthe seed from the metering device to the coulters.Specify the time here in seconds when the metering device shouldstop delivering seed before the point is reached. You will thereby en-sure that no more seed arrives at the coulters when the point isreached. The “T-OFF value must be smaller than the “T-ON” value.

The “T-ON” and “T-OFF” times are dependent on a number of factors.For example:

• Driving speed when reaching the point at which seed is to be ap-plied – “T-ON” or no more seed is to be applied – “T-OFF”

• Type of seed

• Nature of the seed

The guide values are only indications, and adjustment on the field isrequired in all cases.

“T-ON” “T-OFF”

Guide value [s] 2,7 2,2

34

Page 35: E-COM-SINGLE software

ISOBUS settings

Page 4

Keys To the information screen→ Chapter »Opening screen«, page 6

To the previous page

Information on software certification

35

Page 36: E-COM-SINGLE software

Test menu

Test menu These pages are generally of interest to the service technician. Thetest menu can provide you with assistance when troubleshooting orchecking settings.

Exiting the test menu will quit any tests already running. Set values willnot be saved.

Page 1: Informa-tion

Page 2:Test

Key for the service technician

Switch between the software versions

Software version

Target Possible causes fordeviations

Remedy

5 V, ± 0.5 volt Voltage insufficient or too high Check the power supply

12 V, ± 2 volt Voltage insufficient or too high Check the power supply

Below 70 °C The components on the PCB are defective

Inform the Customer Service

Switch between 1 and 0 Sensor defective or set incor-rectly

Inform the Customer Service

36

Page 37: E-COM-SINGLE software

Test menu

Page 3:TestDisplay for power supply to the computers

Hydraulic valve for track marker left [l] or right (R)

Key for the service technician

Enables electrical half-width shut-off testing

Left-hand (L) or right-hand (R) shut-off valves

Work light

Hydraulic valve for pre-emergence marker left [l] or right (R)

37

Page 38: E-COM-SINGLE software

Test menu

Page 4: Test

The tests described here should be performed before each use of themachine. This will allow sources of faults to be easily identified and re-moved.

The speed can be set to between 10 and 120 rpm. For the test run de-scribed here, a speed of 60 rpm should be selected.

Example:The metering device drive motor must be tested.

Activate the drive motor(s) to do so

L = Left (rear)R = Right (front)

The entry is confirmed and the motor will begin to turn at the setspeed.

Display for power supply to the sensors

Key for the service technician

Information on connected motors and sensors

Display only for activation of the motor at the metering device

Activation for test purposes: Motor or metering roller

Input of the rotational speed at which the motor or the metering roller on the metering device is to turn. Motor: 50 – 5000 rpm. Metering roller: 2 – 48 rpm

Activation for test purposes: Manually, by time or revolutions

38

Page 39: E-COM-SINGLE software

Test menu

Test summary

Target Possible causes fordeviations

Remedy

5 V, ± 0.5 volt Voltage insufficient or too high Check the power supply

12 V, ± 2 volt Voltage insufficient or too high Check the power supply

Switch between 1 and 0 Sensor defective or set incor-rectly

Inform the Customer Service

Target Possible causes fordeviations

Remedy

5 V, ± 0.5 volt Voltage insufficient or too high Check the power supply

12 V, ± 2 volt Voltage insufficient or too high Check the power supply

Switch between 1 and 0 Encoder defective Inform the Customer Service

Switch between 1 and 0 Sensor defective or set incor-rectly

Inform the Customer Service

Number of the metering roller

Sensor defective Inform the Customer Service

Set value for “Motor”, ± 10 %

See under “Current” See under “Current”

Set value for “Rotor”, ± 10 % See under “Current” See under “Current”

5 A maximum Some compacted seed or ferti-liser residue may still remain in the metering device

Check the metering device

39

Page 40: E-COM-SINGLE software

Test menu

Page 5: Informa-tion

Details on which date a total area of 10, 100 and 1000 ha was achieved

Information pages for Customer Service

Some blocked functions on the test pages can be activated by entering a PIN.

Total hours [signals from fan and speed sensor]

Total area performance

Total hours [software switched on]

40

Page 41: E-COM-SINGLE software

Test menu

Task processing Twenty different tasks can be stored at once. The following informa-tion is stored from the start of the task for each task:

• Date and time when the task was started

• Date and time when the task was stopped

Machine data

• Period of time the machine has operated for

• Period of time during which the machine was not operated

• Cultivated area, in ha

• Kilometres driven

• Amount of seed or fertiliser spread in kg (calculated)

The task is only completed if a new task has been selected.

To the previous task

To the next task

Delete data

Start the taskThe active task is shown as a number in the information screen.→ Chapter »Opening screen«, page 6

41

Page 42: E-COM-SINGLE software

ECU screen

ECU screen You will find an explanation of the keyboard area and symbols in aseparate operating manual.→ “IsoMatch Tellus” operating manual

42

Page 43: E-COM-SINGLE software

Storage

StorageRemoval Release the plug and withdraw it carefully

Place the dust cap on the plug immediately and secure in place. The plug is very sensitive to mechanical influences and is easily damaged without a dust cap.

Storage There should be no major fluctuations in temperature where the termi-nal is stored. A dry and frost-free storage location is a prerequisite fora long service life of the device.

Dust cap

Locking device

Plug

43

Page 44: E-COM-SINGLE software

Eliminating faults

Eliminating faults Faults can often be eliminated in a fast and easy manner.Before calling Customer Service, refer to the table below to checkwhether you can eliminate the fault yourself. If any faults occur, do notcontinue to sow.

Fault Cause Remedy

The device cannot be switched on

The poles of the supply voltage are reversed

• Have the polarity checked

Power supply interrupted • Check the battery connecting cables

• Check the terminals on the battery

• Check the fuse

• If necessary: Replace the 60 A fuse

• Connect the power cable if the power supply was dis-connected

• Check the voltage:The supply voltage must be 12 – 14 V

System failure Inform the Customer Service

No read out on the display The contrast regulator is set incor-rectly

Make adjustments until the dis-play text is visible

Display does not receive any pulse Start the device again.If, after a new start, nothing is shown in the display or the dis-play cannot be changed, send the device back to the manufacturer.

The computer displays unex-pected values

A mobile telephone, radio or radio antenna is operating too close to the device

Keep a minimum distance of 1 metre

Speed is not displayed or is dis-played too low

Entry of an pulse missing Enter the number of pulses

Cable on the wheel sensor is de-fect or the wheel sensor is defec-tive

Check cable and replace if neces-sary

The device is defective Inform the Customer Service

Fault Cause Remedy

Alarms can be confirmed with the “OK” key. The audible warning signal will stop and you can look for and eliminate the cause of the alarm without being disturbed.

All values have been reset to thefactory settingIncorrect entries or errors on the board

Re-enter all inputs for the ma-chine If the error occurs again, the board is defective and must be re-placed.

44

Page 45: E-COM-SINGLE software

Eliminating faults

Insufficient voltage supplied Check the batteryReplace the fuse if the indicator shows “0”

Insufficient voltage supplied Check the batteryReplace the fuse if the indicator shows “0”

Supply voltage required for thePCB insufficient

Check the batteryCheck the cables of the connect-ed sensors for a short-circuit if theindicator shows “0”

Insufficient voltage supply for theelectrical system

Check the batteryReplace the fuse if the indicatorshows “0”

Temperature on the PCB is higherthan 70 °C

Switch the system off and then onagain. If the temperature remainshigh, inform Customer Service

Short-circuit in the cable of thedrive motor on the metering device

Replace the cable

Drive motor on the metering de-vice is working too laboriously

Clean the metering device

Metering device is blocked by for-eign bodies

Remove foreign bodies

Flap on the metering device isopen and the motor on the meter-ing device is rotating

If you are not emptying anythingfrom the metering device: Closethe flap on the metering device

The machine speed is 0 km/h For information

The time for the free TC-moduletesting is counting down

If required, purchase a TC mod-ule and activate it

Changes to the machine settingswith TaskControl selected

Acknowledge the message to apply the changes in TaskControl. Choosing not to adopt the values can lead to undesirable seed results.

The set fan speed is being exceed-ed by more than 10%

Reduce the fan speed

The fan speed is falling below theset fan speed by more than 10%

Increase the fan speed

The maximum driving speed fromthe calibration is being exceeded

Reduce the driving speed

Fault Cause Remedy

45

Page 46: E-COM-SINGLE software

Eliminating faults

The driving speed is falling belowthe minimum driving speed fromthe calibration

Increase the driving speed

The metering device drive motor isrotating at a speed under 25 rpm

Check the metering device for for-eign bodies

The rotational speed of the meter-ing device drive motor is falling be-low the set rotational speed bymore than 10%

Check the metering device for for-eign bodies

The set rotational speed of the me-tering device drive motor is beingexceeded by more than 10%

Inform the Customer Service

Calibration test not correct Perform the calibration test again

Seed hopper is almost empty Fill the seed hopper

Wrong metering roller fitted Fit the correct metering roller

Flap on the metering device isopen during sowing

Close the flap on the metering de-vice

Flap on the metering device isclosed during the calibration test

Open the flap on the metering de-vice and place a catch pan under-neath

Calibration test:The required speed does not cor-respond to the inputs in the cali-bration test

Select the corresponding speed

Calibration test:The required speed is too high andwill be adjusted

Confirm the alarm and travel atthe specified speed

Fault Cause Remedy

46

Page 47: E-COM-SINGLE software

Index

47

Index

AAlarms 44

BBasic settings

For the seeding machine 13Symbols 14, 41

CCalibration test 21

Filling 28Input 26Key area 21Manual starting 27Mixture 27Performing 26Special seed 27Start the test run 29Symbols 23, 41

EECU screen 42Eliminating faults 44Employer 4

GGEOcontrol 32

Symbols 34

IInformation screen

Key area 10Instruction 4

KKey area

Calibration test 21GEOcontrol 32Information page 2 33, 35Information screen 10

OOther applicable documents 4

PPIN entry 20

RRemoval 43RPM reduction 19

SSafety 4Screens

ECU screen 42Information screen 7Opening screen 6

SensorsSymbols 17

Storage 43Symbols 5

Basic settings 14, 41Calibration test 23, 41GEOcontrol 34Sensors 17Tramlines 30, 31

TTarget group 4Test menu 36

Page 1 36Page 2 37Page 3 36Page 4 38Page 6 40