Dynaflo Dp 60hz Catalog

  • Upload
    npclap

  • View
    963

  • Download
    86

Embed Size (px)

Citation preview

  • 7/25/2019 Dynaflo Dp 60hz Catalog

    1/44

  • 7/25/2019 Dynaflo Dp 60hz Catalog

    2/44

  • 7/25/2019 Dynaflo Dp 60hz Catalog

    3/44

  • 7/25/2019 Dynaflo Dp 60hz Catalog

    4/44

    DynaFlo's DP 4range of submersible pumps aremade of corrosion and abrasion resistant

    stainless steel and have been developed inaccordance with state-of-the-art technology.The DP 4 Pumps are manufactured to thehighest standards for energy efficiency, reliableperformance, rugged construction & longservice life.

    Pumped Liquids:Clean, non-corrosive and non-abrasive liquids

    Operating Conditions: Sand content: Max. 50 g/m

    DYNAFLO DP Series4 Stainless SteelSubmersible Pumps

  • 7/25/2019 Dynaflo Dp 60hz Catalog

    5/44

  • 7/25/2019 Dynaflo Dp 60hz Catalog

    6/44

    4 DP 1APerformance Curves& Selection Chart

  • 7/25/2019 Dynaflo Dp 60hz Catalog

    7/44

    4 DP 2APerformance Curves& Selection Chart

  • 7/25/2019 Dynaflo Dp 60hz Catalog

    8/44

    4 DP 3APerformance Curves& Selection Chart

  • 7/25/2019 Dynaflo Dp 60hz Catalog

    9/44

    4 DP 5APerformance Curves& Selection Chart

  • 7/25/2019 Dynaflo Dp 60hz Catalog

    10/44

    4 DP 8APerformance Curves& Selection Chart

  • 7/25/2019 Dynaflo Dp 60hz Catalog

    11/44

    4 DP 14APerformance Curves& Selection Chart

  • 7/25/2019 Dynaflo Dp 60hz Catalog

    12/44

    DYNAFLO DP Series6 Stainless SteelSubmersible Pumps

  • 7/25/2019 Dynaflo Dp 60hz Catalog

    13/44

  • 7/25/2019 Dynaflo Dp 60hz Catalog

    14/44

    6 DP 17Performance Curves

  • 7/25/2019 Dynaflo Dp 60hz Catalog

    15/44

    6 DP 30Performance Curves

  • 7/25/2019 Dynaflo Dp 60hz Catalog

    16/44

    6 DP 17, DP 30Selection Chart

  • 7/25/2019 Dynaflo Dp 60hz Catalog

    17/44

    6 DP 46Performance Curves

  • 7/25/2019 Dynaflo Dp 60hz Catalog

    18/44

    6 DP 60Performance Curves

  • 7/25/2019 Dynaflo Dp 60hz Catalog

    19/44

    6 DP 46, DP 60Selection Chart

  • 7/25/2019 Dynaflo Dp 60hz Catalog

    20/44

    DYNAFLO DP Series8 Stainless SteelSubmersible Pumps

  • 7/25/2019 Dynaflo Dp 60hz Catalog

    21/44

  • 7/25/2019 Dynaflo Dp 60hz Catalog

    22/44

    8 DP 77Performance Curves

  • 7/25/2019 Dynaflo Dp 60hz Catalog

    23/44

    8 DP 77Performance Curves

  • 7/25/2019 Dynaflo Dp 60hz Catalog

    24/44

    8 DP 77Selection Chart

  • 7/25/2019 Dynaflo Dp 60hz Catalog

    25/44

    8 DP 95Performance Curves

  • 7/25/2019 Dynaflo Dp 60hz Catalog

    26/44

    8 DP 95Performance Curves

  • 7/25/2019 Dynaflo Dp 60hz Catalog

    27/44

    8 DP 95Selection Chart

  • 7/25/2019 Dynaflo Dp 60hz Catalog

    28/44

    DYNAFLO DP Series10 Stainless SteelSubmersible Pumps

  • 7/25/2019 Dynaflo Dp 60hz Catalog

    29/44

    771.7

    771.7

    947.7

    947.7

    947.7

    1123.7

    1123.7

    1123.7

    1299.7

    1299.7

    1299.7

    1475.7

    1475.7

    1475.7

    1651.7

    1651.7

    1651.7

    237

    237

    237

    237

    237

    237

    237

    237

    237

    237

    237

    262

    262

    262

    262

    262

    262

    241

    241

    241

    241

    241

    241

    241

    241

    241

    241

    241

    274

    274

    274

    274

    274

    274

    771.7

    771.7

    947.7

    947.7

    947.7

    1123.7

    1123.7

    1123.7

    1299.7

    1299.7

    1299.7

    241

    241

    241

    241

    241

    241

    241

    241

    241

    241

    241

    247

    247

    247

    247

    247

    247

    247

    247

    247

    247

    247

    DP 21 - 1

    -

    DP 1 - A

    - -

    DP 1 -

    -

    DP 1 - -

    DP 1 -

    DP 21 -4A

    DP 1 -4

    DP 1 -4

    DP 15 -5A

    DP 1 -

    -

    DP 15 -6A

    DP 1 -

    DP 21 -

    DP 1 - 7A

    DP 21 - 7

    DP 21 -

  • 7/25/2019 Dynaflo Dp 60hz Catalog

    30/44

    10 DP 125Performance Curves

  • 7/25/2019 Dynaflo Dp 60hz Catalog

    31/44

    10 DP 125Performance Curves

  • 7/25/2019 Dynaflo Dp 60hz Catalog

    32/44

    10 DP 125Selection Chart

  • 7/25/2019 Dynaflo Dp 60hz Catalog

    33/44

    10 DP 160Performance Curves

  • 7/25/2019 Dynaflo Dp 60hz Catalog

    34/44

    10 DP 160Performance Curves

  • 7/25/2019 Dynaflo Dp 60hz Catalog

    35/44

    10 DP 160Selection Chart

  • 7/25/2019 Dynaflo Dp 60hz Catalog

    36/44

    10 DP 215Performance Curves

    35

    60 Hz, SF 1.1510 DP 215

    ISO 9906 Annex A

    3

    3A

    3AA

    2

    2A

    2AA

    4A

    4AA

    4

    1

    23.0

    25.0

    27.0

    P2(kw)33.0

    29.0

    31.0

    100 150 2000 Q[m/h]3

    50 250 300 350

    1000 2000 3000 4000 5000 6000 Q[l/min]0

    kw/stage

    NPSH

    1000 2000 3000 4000 5000 6000 Q[l/min]0

    0

    [m]H

    50

    100

    150

    200

    100

    200

    300

    400

    500

    600

    0

    H[ft]

    700

    800

    300 600 900 1200 15000U.S.GPM

    1A

  • 7/25/2019 Dynaflo Dp 60hz Catalog

    37/4436

    23.0

    25.0

    27.0

    P2(kw)33.0

    29.0

    31.0

    100 150 2000 Q[m/h]3

    50 250 300 350

    1000 2000 3000 4000 5000 6000 Q[l/min]0

    1000 2000 3000 4000 5000 6000 Q[l/min]0

    kw/stage

    NPSH

    60 Hz, SF 1.15

    10 DP 215

    ISO 9906 Annex A

    400

    600

    800

    1000

    1200

    H[ft]

    1400

    300 600 900 1200 15000U.S.GPM

    80

    [m]H

    120

    160

    200

    240

    280

    320

    360

    400

    6

    7

    5

    5A

    5AA

    6AA

    6A

    7AA

    7A

    10 DP 215Performance Curves

  • 7/25/2019 Dynaflo Dp 60hz Catalog

    38/44

    10 DP 215Selection Chart

    10 DP 215 Selection Chart

    DP 215-1

    DP 1 -1

    DP 215-2AA

    DP 1 -

    DP 215-2

    DP 21 - AA

    DP 15-

    DP 21 -

    DP 15-4AA

    DP 215-4A

    DP 215-4

    DP 215-5AA

    DP 215-5A

    DP 215-5

    DP 15-6AA

    DP 1 -

    DP 215-6

    DP 21 -7AA

    DP 15-7

    DP 21 -

    Type L/MIN

    30

    40

    60

    75

    85

    100

    125

    125

    150

    150

    150

    175

    175

    200

    230

    230

    230

    250

    250

    300

    22

    30

    45

    55

    63

    75

    93

    93

    110

    110

    110

    132

    132

    147

    170

    170

    170

    185

    185

    220

    W M/H

    H:TOTAL

    HEADINMETERS

    MAX.current

    90.4

    124

    172

    214

    266

    284

    376

    376

    440

    440

    440

    54.7

    75

    104

    130

    161

    172

    228

    228

    266

    266

    266

    Amp

    Motor

    37

    52

    77

    93

    109

    132

    148

    163

    187

    202

    218

    244

    260

    278

    302

    318

    334

    351

    366

    389

    35

    49

    74

    89

    103

    128

    142

    155

    180

    194

    208

    235

    249

    266

    291

    305

    319

    337

    350

    372

    33

    46

    71

    85

    97

    122

    134

    146

    171

    183

    194

    223

    235

    250

    275

    288

    300

    317

    329

    349

    31

    42

    67

    80

    90

    116

    126

    132

    161

    171

    181

    210

    221

    233

    260

    270

    281

    297

    307

    326

    28

    38

    63

    75

    84

    109

    118

    127

    152

    161

    170

    198

    207

    219

    244

    254

    263

    279

    287

    306

    25

    36

    58

    70

    79

    102

    111

    119

    142

    151

    159

    186

    194

    206

    230

    239

    248

    261

    270

    287

    21

    34

    52

    65

    74

    94

    103

    111

    131

    140

    148

    172

    181

    193

    214

    223

    232

    242

    250

    268

    16

    30

    43

    57

    67

    83

    92

    101

    117

    126

    135

    154

    164

    176

    192

    202

    211

    217

    225

    244

    11

    25

    32

    47

    58

    67

    77

    87

    97

    107

    117

    130

    140

    153

    164

    174

    185

    183

    192

    212

    5

    17

    19

    33

    45

    46

    57

    69

    70

    81

    93

    98

    110

    125

    126

    138

    151

    140

    150

    174

    46.08

    46.08

    55.78

    55.78

    55.78

    65.60

    65.60

    65.60

    75.42

    75.42

    75.42

    90.76

    90.76

    90.76

    101

    101

    101

    Stages

    1

    1

    2

    2

    2

    3

    3

    3

    4

    4

    4

    5

    5

    5

    6

    6

    6

    7

    7

    7

    Discha

    rge:RP6or6Flange

    1000 550050004500400035003000250020001500 Weight

    kg60 21018015012090 330300270240

    500

    30

    38

    54

    78

    95

    112

    135

    151

    168

    191

    207

    223

    249

    266

    285

    308

    325

    342

    359

    374

    399

    All technical information is subject to change without notice.

    37

  • 7/25/2019 Dynaflo Dp 60hz Catalog

    39/4438

    SubmersiblePump Cable Selection

    Motor Rating Copper Wire Size

    115

    115

    230

    230

    230

    230

    230

    230(Cont.)

    230(Cont.)

    230(Cont.)

    230(Cont.)

    230(Cont.)

    230(Cont.)

    1/2

    1/2

    1/2

    1/2

    3/4

    1

    1.5

    2

    3

    5

    7.5

    10

    15

    Volts HP

    130

    100

    550

    400

    300

    250

    190

    150

    120

    0

    0

    0

    0

    14

    210

    160

    880

    650

    480

    400

    310

    250

    190

    110

    0

    0

    0

    12

    340

    250

    1390

    1020

    760

    630

    480

    390

    300

    180

    120

    0

    0

    10

    540

    390

    2190

    1610

    1200

    990

    770

    620

    470

    280

    200

    160

    0

    8

    840

    620

    3400

    2510

    1870

    1540

    1200

    970

    750

    450

    310

    250

    170

    6

    1300

    960

    5250

    3880

    2890

    2380

    1870

    1530

    1190

    710

    490

    390

    270

    4

    1960

    1460

    7960

    5880

    4370

    3610

    2850

    2360

    1850

    1110

    750

    600

    430

    2

    2910

    2160

    11770

    8720

    6470

    5360

    4280

    3620

    2890

    1740

    1140

    930

    660

    0

    3540

    2630

    7870

    6520

    5240

    4480

    3610

    2170

    1410

    1160

    820

    00

    Single Phase Motor Maximum Cable Length (Motor to service entrance)

    Motor Rating Copper Wire Size

    200V

    200V

    200V

    200V

    200V

    200V

    200V

    200V

    200V

    200V

    230V

    230V230V

    230V

    230V

    230V

    230V

    230V

    230V

    230V

    460V

    460V

    460V

    460V

    460V

    460V

    460V

    460V

    460V

    460V

    460V

    460V

    460V

    460V

    460V

    575V

    575V

    575V

    575V

    575V

    575V

    575V

    575V

    575V

    575V

    575V

    575V

    575V

    575V

    575V

    1.5

    2

    3

    5

    7.5

    10

    15

    20

    25

    30

    1.5

    23

    5

    7.5

    10

    15

    20

    25

    30

    1.5

    2

    3

    5

    7.5

    10

    15

    20

    25

    30

    40

    50

    60

    75

    100

    1.5

    2

    3

    5

    7.5

    10

    15

    20

    25

    30

    40

    50

    60

    75

    100

    Volts HP

    310

    240

    180

    110*

    0

    0

    0

    0

    0

    0

    360

    280210

    130*

    0

    0

    0

    0

    0

    0

    1700

    1300

    1000

    590

    420

    310

    0

    0

    0

    0

    0

    0

    0

    0

    0

    2620

    2030

    1580

    920

    660

    490

    330*

    0

    0

    0

    0

    0

    0

    0

    0

    14

    500

    390

    290

    170

    0

    0

    0

    0

    0

    0

    580

    450340

    200

    140*

    0

    0

    0

    0

    0

    2710

    2070

    1600

    950

    680

    500

    340*

    0

    0

    0

    0

    0

    0

    0

    0

    4180

    3250

    2530

    1480

    1060

    780

    530

    410*

    0

    0

    0

    0

    0

    0

    0

    12

    790

    610

    470

    280

    200

    150*

    0

    0

    0

    0

    920

    700540

    320

    230

    170*

    0

    0

    0

    0

    4270

    3270

    2520

    1500

    1070

    790

    540

    410

    330*

    270*

    0

    0

    0

    0

    0

    6580

    5110

    3980

    2330

    1680

    1240

    850

    650

    520

    430*

    0

    0

    0

    0

    0

    10

    1960

    1520

    1160

    690

    490

    370

    250

    190*

    0

    0

    2260

    17401340

    800

    570

    420

    290

    220*

    180*

    0

    8050

    6200

    3700

    2640

    1960

    1340

    1030

    830

    680

    500

    410*

    0

    0

    0

    5750

    4150

    3060

    2090

    1610

    1300

    1070

    790

    640*

    540*

    0

    0

    6

    3050

    2360

    1810

    1000

    770

    570

    390

    300

    240*

    200*

    3510

    27102080

    1240

    890

    660

    450

    350

    280

    230*

    5750

    4100

    3050

    2090

    1610

    1300

    1070

    790

    640

    540*

    440*

    0

    4770

    3260

    2520

    2030

    1670

    1240

    1000

    850

    690*

    0

    4

    3610

    2760

    1660

    1180

    880

    600

    460

    370

    310

    41303170

    1900

    1350

    1010

    690

    530

    430

    350

    6260

    4680

    3200

    2470

    1990

    1640

    1210

    980

    830

    680*

    500*

    3860

    3110

    2650

    1900

    1540

    1300

    1060

    790*

    2

    5420

    4130

    2490

    1770

    1330

    910

    700

    570

    470

    62004730

    2850

    2030

    1520

    1040

    810

    650

    540

    7050

    4810

    3730

    3010

    2490

    1830

    1480

    1250

    1030

    760*

    5830

    4710

    3880

    2860

    2310

    1960

    1600

    1190

    0

    3050

    2170

    1640

    1110

    860

    700

    580

    3490

    2480

    1870

    1280

    990

    800

    660

    5900

    4580

    3700

    3060

    2250

    1810

    1540

    1260

    940

    4770

    3510

    2840

    2400

    1970

    1460

    00

    3670

    2600

    1970

    1340

    1050

    840

    700

    4200

    2980

    2260

    1540

    1200

    970

    800

    7110

    5530

    4470

    3700

    2710

    2190

    1850

    1520

    1130

    5780

    4230

    3420

    2890

    2380

    1770

    000

    4440

    3150

    2390

    1630

    1270

    1030

    850

    5080

    3600

    2740

    1860

    1450

    1170

    970

    5430

    4500

    3290

    2650

    2240

    1850

    1380

    7030

    5140

    4140

    3500

    2890

    2150

    0000

    1260

    970

    740

    440

    310

    230

    160

    0

    0

    0

    1450

    1110860

    510

    360

    270

    180*

    140*

    0

    0

    6730

    5150

    3970

    2360

    1690

    1250

    850

    650

    530

    430

    320*

    0

    0

    0

    0

    8060

    6270

    3680

    2650

    1950

    1340

    1030

    830

    680

    500*

    410*

    0

    0

    0

    8

    Three Phase Motor Maximum Cable Length (Motor to service entrance) 60HZ

    1.This table is based on copper wire. Ifaluminum wire is used it must be twosizes larger.Example: When the table calls for #12copper wire you would use #10aluminum wire.

    2.Single phase control boxes may beconnected at any point of the totalcable length.

    3.The portion of the total cablewhich is between the serviceentrance and a three phasemotor starter should not exceed25% of the total mximum lengtht o a s su re r e l i ab l e s t a r t e roperation.

    Lengths marked meet the U.S.N a t i o n a l E l e c t r i c a l C o d e

    ampacity only for individual lengths without meet the code

    Local code requirements mayvary.

  • 7/25/2019 Dynaflo Dp 60hz Catalog

    40/4439

    CHECK VALVEThis only apply to horizontal installation, the built-in check valve of DP pumps is not appropriate for horizontalapplication, to install a vertical or horizontal check valve is a must to avoid reverse rotation of both pump and motor.

    And the whole flow inducer pump motor set must be installed slanting minimum of 15 degree as illustrated ondrawing per Figure 1.2

    OTHER APPLICATIONDP/DS Pumpsare also perfect for fire fighting, booster pump or transfer pump application, less maintenance, does notneed pump room, since it is installed inside the underground cistern tank, there is no risk for fire damage as it issubmerge in water and no worry about loose prime like in most cases. DP/DS pumpsare very suitable for all

    applications due to its very wide pressure range against your required capacity that can meet the fire pump and jockeypump, booster or transfer pump, water line pressure requirement.

    FLOW INDUCER

    SIZE OF THE FLOW INDUCERFLANGESHEAD PLATE

    BOLT AND NUT

    A.

    B.C.D.

    E.

    To attain the maximun cooling flow capacity the size of the flow inducer must be the same with the

    size of the pump and motor. If your pump and motor are for 4 min casing then use 4 dia. Pipe foryour flow inducer.

    SUBMERSIBLE PUMP HORIZONTALBOOSTER IN-LINE ASSEMBLY

    VERTICAL OR HORIZONTAL INSTALLATIONDP/DS Pumpscan be installed either vertically or horizontally. Most importantly is to install the submersible pump motorset inside a Flow Inducer (shroud). It is a PVC or Steel Pipe which control and increases the flow of water. The Mainpurpose, the flow velocity of water must come from the bottom of the Submersible Motor, flow through its surfacebody to control its temperature, and to increase the service factor of the motor, before entering the suctioninterconnector of the pump all the way up to the overhead tank or to its discharge point. As illustrated on the drawingper Figure 1.1. In this case, the submersible motor will meet its required minimum cooling flow capacity. If not, thetemperature of the motor will rise which will definitely damage the thrust bearing and the stator, worst it will seriously

    damage the entire winding of the motor. And always remember high temperature shorten the life span of our motor.

    Figure 1.1

    DISCHARGE PIPE

    DISCHARGE FLANGECABLESTABILIZERS

    AIR RELEASE VALVE

    F.

    G.H.I.

    J.

    B

    C

    I

    A

    J

    D C E

    G

    H

    F

  • 7/25/2019 Dynaflo Dp 60hz Catalog

    41/44

  • 7/25/2019 Dynaflo Dp 60hz Catalog

    42/44

    4 SubmersiblesTypical Installations

    41

    TECHNICAL DATA

    DYNAFLO

    PUMPS

    ABOVE GROUND

    INSTALLATION

    1. PUMP 2. CERTIFICATE 3. SPLICE KIT 4. TORQUE ARRESTOR

    5. TORQUE STOPS 6. ELECTRIC CABLE 7. SAFETY ROPE

    8. PITLESS ADAPTER 9. WELL CAP OR

    WELL SEAL10. CONTROL BOX

    11. LIGHTNING ARRESTOR 12. FITTINGS 13. PRESSURE SWITCH

    14. PRESSURE GAUGE 15. STORAGE TANK 16. PRESSURE RELIEF

    VALVE

    Dynao

    Stainless steel

    casing and

    bowls, bronze

    castings and

    lightning pro

    tected motor.

    Two or three

    wire models

    available.

    Dynao optional 5-year

    Protection Plan covers up

    to 1 1/2 hp. pump and

    motor against failure due

    to wear, abrasion, corrosion

    or even lightning.

    Spaced at regular

    distances apart in the

    well, to keep wire from

    rubbing against the

    side of the wall.

    Recommended for units

    over 1 1/2 h.p. Models

    up to 1 1/2 h.p. have

    lightning protection

    built right into the motor.

    For underground

    connection of wellpipe to horizontal pipe

    providing a sanitary

    seal.

    Indicates system

    pressure at all times.

    Connecter crimps

    and heat-shrink tubing

    seals wire lead

    connections to

    electric.

    Either three-wire or two-

    wire. Selection of

    proper size wire assures

    required voltage to

    motor.

    Keeps debris out of well.Allows entry into the well.

    Plumbing ttings usually included

    in typical water system

    hook-ups include tank

    cross tee, boiler drain

    ttings, unions and

    other necessary items.

    Offers water storage for

    fewer lump cycles.

    Provides air cushion to

    operate against. Tank

    should be sized so that

    draw down is equal tocapacity of pump.

    Absorbs thrust of motor

    start-ups; keeps pump

    centered in well.

    Various types are

    available.

    Sometimes used to

    support the weight of the

    pump and prevents pump

    from falling to the bottom

    of the well.

    Contains components of

    the motor required with

    all three-wire

    models.

    Senses system pressure

    and automatically turns

    pump on and offf.

    Protection against pres-

    sure build-up. Particularly

    vital where the pump is

    capable of producing

    more pressure than theworking limits of the tank.

    (Include stop and waste valve in illustration)

    Prosurance

  • 7/25/2019 Dynaflo Dp 60hz Catalog

    43/44

  • 7/25/2019 Dynaflo Dp 60hz Catalog

    44/44