DT DAQ status and plans. Cristina Fernández Bedoya , Ignacio Redondo Fernández. Intro/Outline. Present status is sound Permanently blocked channels 0-1ROB (down from 1) Downtime: 0 % (down from 1%) News Suppression of TS debug data Automatic TTSResync enabled Plans: Alarm Automation - PowerPoint PPT Presentation
Citation preview
27/09/2010 Ignacio Redondo CIEMAT 1
DT DAQ status and plans
Cristina Fernández Bedoya , Ignacio Redondo Fernández
27/09/2010 Ignacio Redondo CIEMAT 2
Intro/Outline• Present status is sound
• Permanently blocked channels 0-1ROB (down from 1) • Downtime: 0 % (down from 1%)
• News– Suppression of TS debug data – Automatic TTSResync enabled
• Plans:– Alarm Automation– Analysis of TestPulse runs taken– 904 teststand
27/09/2010 Ignacio Redondo CIEMAT 3
Trigger “zero”-supression Cristina,Luigi,Gianni
• TS data (20 bxs) only readout if trigger primitive present in the sector.
• Otherwise send a 32 bit word. • Event size of emtpy event reduced by 6 from
1176 bytes/FED to
192 bytes/FED
Eve
nts
Bytes
Mean
±RMS
YB-2 YB-1 YB0 YB+1 YB+2
FEDs
770-4
1123 ±325
1120
±331
1127
±311
1122
±316
1117
±325
0ed 245
±42
245
±43
245
±37
245
±40
245
±39
FEDs
775-9
1134
±322
1118
±323
1119
±327
1120
±321
1125
±320
0ed 245
±37
245
±36
245
±41
244
±35
245
±35
27/09/2010 Ignacio Redondo CIEMAT 4
Enables the switch to <10 DDU system
• Required to beaf-up spares pool – Symmetric configuration (5 DDU)– External wheels configuration (7 DUU: 2,1,1,1,2)
• How and when to be decided:
• Probably during Christmas stop after Heavy Ion run.
27/09/2010 Ignacio Redondo CIEMAT 5
Automatic resync enabled• Automatic resync enabled since August 26• At present, DDU goes into OOS if more than 15
ROBs (2.5 Minicrates) are blocked (programmable). Already implemented in April.
• DDU OOS is answered automatically by a resync from cDAQ
• Being monitored: – 83 times, – 5 out of access
• DT DAQ hasdisappeared from downtime reports (0.8 % => 0 %)
Downtime before 08/26/2010
27/09/2010 Ignacio Redondo CIEMAT 6
DAQ Alarm Automation• DAQ alarm automation status:
– Blocked channels above threshod =>TTSResync– SC crate off =>PVSS alarm to DCS shifter (SMS?)
• In general, only catched by expert look at DQM/DCS dashboard
– DDU input channel blocked =>VME command? SMS? (or GOLROS not working) – QPLL unlocks => Need to know the clock status– FPGA not programmed => TTS signal? (most frequent SEU) VME command?– VME access problem =>Probably will have to power
(now reported in the config phase) cycle manually, SMS PVSS alarm?
• As luminosity increases we will start to be sensitive to SEU failures at the ROS that are rare now
27/09/2010 Ignacio Redondo CIEMAT 7
Error Report to cDAQ• In any of the errors in the previous list, as a
first step, the central shifter should get an alarm/warning and call the DT field manager.
• Communications channels where to implement these alarms in our FM/DAQ xdaq are already in place
• We should be able to mask this alarms to cope with persistent errors.
27/09/2010 Ignacio Redondo CIEMAT 8
Firmware upgrades
• By the end of the year in order to improve various aspects we plan to upgrade:
• DDU firmware– Internal mapping of the number of ROS errors for
Out-Of-Synch.
• ROS firmware– Better event size monitoring. – Reduce GOL power on/off cycles – Possibility to remap TTSHardReset (now eq. to TTSResync)
to FPGA reloading – Improve ROS start-up procedure
• All this things are still under development, hopefully all of them are doable.
Vincenzo/Cristina
27/09/2010 Ignacio Redondo CIEMAT 9
Checked in the Online DQM various MiniDAQ TP runs taken aprox once/month in 2010:
130036 132842 135501 138869 143456 145353 1464694-march-10 08-apr-10 15-may-10 28-jun-10 20-aug-10 09-sep-10 23-sep-10
Things checked: - data integrity, - event size, - occupancies, - TP time position, - TP L1A BXid, - noisy cells
Some conclusions:-Not all known read-out errors appear in these runs, but most of them (the sample is quite representative)
-All known FE (FEB, SLs, etc) errors appear in these runs
-Noisy cells in TP have a very low noise frequency (<500 Hz) and do not correspond with the noisy cells seen with HV on
-Some trigger problems are also visible when reading with DCC
MiniDAQ Test Pulse
Cristina
27/09/2010 Ignacio Redondo CIEMAT 10
Some anomalous behaviours:
-Some TDC fatal errors in March and April runs that were probably due to a wrong configuration (solved afterwards).
-Two chambers in which the TP is largely shifted (and not related with any other problem). Looks also like a configuration problem (never happened afterwards)
Run 130036 YB+1 S10 MB2
Run 132842 YB+1 S10 MB2 OK, peak in 680 TDC counts
BAD, peak in 1250 TDC counts
27/09/2010 Ignacio Redondo CIEMAT 11Cristina
• One thing to remark is that this year we have 3 FEB death.• Last time such problems have been seen:
– January 2008: YB+1 S9 MB3 SL1 FEB 13 (short in VCC HV discharges)– January 2008: YB-1 S8 MB4 SL1 FEB 20 (short in VDD capacitor)
• Test Pulse trainining during next Oncall Training? • Offline shifter please check known problem list/browser (
https://twiki.cern.ch/twiki/bin/view/CMS/DTshiftFAQ2010x08x19) before submitting report to elog.
TP error Summary
27/09/2010 Ignacio Redondo CIEMAT 12
RO test stand in 904 Cristina,Vincenzo,Ignacio
•“Good” LHC Clock•TTC (BG-O commands)•DDU:
•DDU prototype•CAEN VME bridge•TTCvi, TTCex
•SC:•Linco•Tim •1 ROS
•Able to test ROS-DDU link (GOL)and debug DDU board.
27/09/2010 Ignacio Redondo CIEMAT 13
Cristina,Vincenzo,Ignacio
•“Micro”-crate (CCB+ROB)
installed by Cristina. •Provides Minicrate data
• Labview linco driver nearly ready,• Will enable to replicate Madrid ROS tests.• Decoupled DDU and ROS control• Ready to install local DT DAQ software
RO test stand in 904
27/09/2010 Ignacio Redondo CIEMAT 14
More
27/09/2010 Ignacio Redondo CIEMAT 15
Testpulses runs are not suited to make a thorough study of the local trigger chain due to Superlayer shifts. In particular, MB4s (2 cells shift) will never give HH triggers.Still, some “larger” problems can be spotted:
Empty (DTTF YB-2 S4 MB4 masked)
Cristina
27/09/2010 Ignacio Redondo CIEMAT 16
DDU trigger data wrong, too many pre-triggering
27/09/2010 Ignacio Redondo CIEMAT 17
DDU trigger data OK but DCC sees only HL and 1 bx later
27/09/2010 Ignacio Redondo CIEMAT 18
How these plots should look like: