2
Principle of operation Configuration Air entry Capacity www.BaltimoreAircoil.eu Maximum entering fluid temperature Dry and adiabatic cooling products Operational safety (hygiene) Low sound Energy efficiency Easy maintenance Water saving Best G A counterflow axial fan induced draft DFCV-AD cooler 220 - 1620 kW 60°C C A A D B counterflow axial fan induced draft DCV-AD condenser 340 - 1030 kW / C A A D B counterflow axial fan induced draft SP cooler 340 - 1560 kW 60°C C A A D B counterflow axial fan induced draft DFCV cooler 220 - 1500 kW 60°C D D A A A counterflow axial fan induced draft 250 - 2000 kW 60°C A A B D E TVFC cooler Tab v06 EN © 2018 Baltimore Aircoil International nv

Dry and adiabatic cooling products - BAC Europe...Dry and adiabatic cooling products Dry and adiabatic cooling products Tab_DAC_ENv06 Dry or air cooled products Dry or air-cooled products

  • Upload
    others

  • View
    11

  • Download
    2

Embed Size (px)

Citation preview

Page 1: Dry and adiabatic cooling products - BAC Europe...Dry and adiabatic cooling products Dry and adiabatic cooling products Tab_DAC_ENv06 Dry or air cooled products Dry or air-cooled products

Principle ofoperation

Configuration

Air entry

Capacity

www.BaltimoreAircoil.eu

Maximum entering fluid temperature

Dry and adiabatic cooling products

Operational safety (hygiene)

Low sound

Energy efficiency

Easy maintenance

Water saving

BestG A

counterflow

axial fan induced draft

DFCV-AD cooler

220 - 1620 kW

60°C

C

A

A

D

B

counterflow

axial fan induced draft

DCV-AD condenser

340 - 1030 kW

/

C

A

A

D

B

counterflow

axial fan induced draft

SP cooler

340 - 1560 kW

60°C

C

A

A

D

B

counterflow

axial fan induced draft

DFCV cooler

220 - 1500 kW

60°C

D

D

A

A

A

counterflow

axial fan induced draft

250 - 2000 kW

60°C

A

A

B

D

E

TVFC cooler

Tab v

06 E

N ©

2018

Balt

imor

e Airc

oil In

terna

tiona

l nv

Page 2: Dry and adiabatic cooling products - BAC Europe...Dry and adiabatic cooling products Dry and adiabatic cooling products Tab_DAC_ENv06 Dry or air cooled products Dry or air-cooled products

Dry and adiabatic cooling productsDr

y an

d ad

iaba

tic co

olin

g pr

oduc

ts

Tab_DAC_ENv06

Dry or air cooled products Dry or air-cooled products cool liquids or condensate gases in closed circuits via sensible heat transfer from high-density finned coil to air at ambient dry bulb temperature.

Key benefits• Eliminates water treatment and reduces water usage • Eliminates plumes • Reduced maintenance • Eliminates Legionella risks

Why go for evaporative rather than dry cooling?• When you need a fluid outlet temperature close to the design ambient dry bulb temperature • To save on energy costs • If the cooling unit plan area is compact or restricted

Adiabatic products Adiabatic products are air-cooled coolers or condensers with adiabatic pre-coolers. Before the fan draws the ambient air through the finned coil, the air is pre-cooled adiabatically when traversing an humidification pad. This evaporates the water in the air, thus boosting the cooling capacity.

Key benefits• low process temperatures • saves more than 80% on annual water compared to cooling towers • up to 40% increased capacity compared to dry cooling (air temperatures approaching wet bulb

temperature) • reduced energy consumption • operational safety: no water recirculation, no stagnant water, no aerosol generation, no water carry-over