10
May 2021 DR Koncertsalen Technical Specifications CONTACT: www.drkoncerthuset.dk Adress: DR Koncerthuset Ørestads Boulevard 13 2300 KBH S Nav: (alt./lat.), type: “55° 3929N, 12° 3521E” in navsys type: 55.658056,12.589167 in google maps Concert booking Lars Skovgaard / +45 2214 2022 / [email protected] Concert Production: Kasper Bæk / +45 2854 1252 /[email protected]

DR Koncertsalen

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: DR Koncertsalen

May 2021

DR Koncertsalen Technical Specifications

CONTACT: www.drkoncerthuset.dk Adress: DR Koncerthuset

Ørestads Boulevard 13 2300 KBH S

Nav: (alt./lat.), type: “55° 39′ 29″ N, 12° 35′ 21″ E” in navsys type: 55.658056,12.589167 in google maps

Concert booking Lars Skovgaard / +45 2214 2022 / [email protected] Concert Production: Kasper Bæk / +45 2854 1252 /[email protected]

Page 2: DR Koncertsalen

May 2021

GENERAL INFORMATION:

LOAD IN & PARKING: Parking is located at OERESTADS BOULEVARD 13, 2300 COPENHAGEN S. When you are in the parking lot, drive left and you will reach the ramp leading you to the loading dock. Call your contact person from DR Koncerthuset, who will open the gate to the loading dock. (Height of the gate is 4,30 meters) Busses Bus parking is available on the right side of the ramp. Landline power is available immediately upon arrival. (3x32A red CEE) Loading dock is located on floor -1. Lift is located at loading dock (lift dimensions, 7000KG, 210cm high, 205cm wide, 500cm deep)

ENTRANCE (MUSICIANS/CREW): Through loading dock PRODUCTION OFFICE: A production office with wifi is available upon request DRESSING ROOMS & CATERING AREA: DR Koncerthuset offers three (3) dressing rooms, all facilitated with bathroom/showers, a full body mirror and furniture. A large hospitality area/ green room is located behind stage, and is equipped with a full size fridge and toilets. DR Koncerthuset does not offer kitchen facilities or the possibility of setting up road kitchens.

Page 3: DR Koncertsalen

May 2021

COMMUNICATION: Free WLAN is available – please choose the network with SSID “DR Guest” The network is open. There is no wifi at the bus parking. VENUE CREW: Depends on production size, but as a minimum: 1 x Venue representative 1 x FOH sound engineer * 1 x Light engineer * Please note: If only one sound engineer is booked, monitors are done from FOH if act is not bringing their own monitor engineer. SMOKE/HAZE: Only water based hazers are allowed. For example Swefog V3000, MDG Atmosphere etc.

SFX The use of SFX (Pyro, confetti etc.) HAS to be discussed with your production contact during the advance, and will incur additional fees for permits, cleaning etc.

dB LIMITS: DR Koncerthuset strives to ensure a healthy concert experience for our audience, and to comply with the noise regulations of the EU for our employees, we are enforcing a dB limit of 103 dB(A) averaged over 15 min (Leq 15 = 103 dB(A)). A properly calibrated measurement system (www.10EaZy.com) will be available to the sound engineer at FOH where dB values will be measured. The house engineer will engage in reducing the overall sound level if rules are not complied with. SMOKING: National law prohibits smoking in public areas, including but not limited to performance and backstage facilities. Smoking is allowed outside the venue always, and at the balcony on the 4th floor from 6 pm weekdays, and all day on weekends.

MERCHANDISE: DR Koncerthuset does not have a dedicated merch booth, but can offer a large area in the main foyer to set up merchandise for sale. Please not that we are not able to provide float, nor staff to man the booth.

Page 4: DR Koncertsalen

May 2021

TECHNICAL SPECIFICATIONS: SOUND: FOH position is located on 1.balcony, center.

PA-SYSTEM: d&b V-Series. A total of: 26 x d&b V8 16 x d&b V12 19 x d&b Vsub 2 x d&b E8 2 x d&b T10 10 x d&b D80 amp

Distributed into: MAIN LEFT: 6 x V8 + 4 x V-SUB (flown behind V8 stack) CENTER: 3 x V-SUB MAIN RIGHT: 6 x V8 + 4 x V-SUB (flown behind V8 stack) SIDE LEFT: 5 x V12 SIDE RIGHT: 5 x V12 BACK LEFT: 2 x V-SUB + 2 x V8 + 4 x V12 BACK CENTER: 2 x V8 BACK RIGHT: 2 x V-SUB + 4 x V8 + 2 x V12 PARTERRE LEFT: 3 x V8 + 1 x E8 PARTERRE RIGHT: 3 x V8 + 1 x E8 PARTERRE optional: 2 x V-SUBS per side ground stacked FRONT FILLS (center) 2 x T10 All driven on D80 amplification R1 speaker management /remote operating software accessable @ FOH

F.O.H.

1 x DiGiCo SD ten w. SD-rack (56in, 32out) via Optocore fiber

1 x Waves soundgrid system (integrated) with “Pro show bundle”

MONITOR - Monitors are run from FOH (as standard)

8 x L’acoustics 115XT HiQ on 6 sends

Page 5: DR Koncertsalen

May 2021

MICROPHONES:

1 x Shure Beta 52A

1 x Shure Beta 91A

1 x Audix D6

5 x Sennheiser e904

2 x Audix D2

2 x Audix D4

2 x Senneheiser e609

8 x Shure SM57

8 x Shure Beta 58A

2 x Shure SM 58

2 x Shure KSM9

2 x AKG c414 XLS

6 x Neumann KM84

2 x DPA 4011

12 x Radial J48 Active DI’s

4 x Radial JDI passive DI’s

AUX SOUND POWER:

Stage: 1 x 3 phase 63A CEE form at SL

FOH: 1 x single phase 16A CEE form

Page 6: DR Koncertsalen

May 2021

LIGHT: House Lighting desk is and GrandMA3 Fullsize located at Front of House, 1st balcony next to the sound desk

LIGHTS: The house holds 200 dimmer channels and 2 lighting galleries.

Front Gallery has 22 Strand Profiles 2,5kw and a wide selection of gels.

The back gallery has 20 Strand Profiles 2,5kw and a wide selection of gels

AUX POWER: Above the auditorium. several 63A CEE connections distributed over the full roof.

1 set of PowerLock (250A) placed Upstage center

Floor: Stage right has 2 x 3x63A CEE outlet

Stage left has 2x 3x63A CEE Outlet + 1 x PowerLock (250A)

Page 7: DR Koncertsalen

May 2021

LIGHTPLOT & PATCH:

Page 8: DR Koncertsalen

May 2021

STAGE: Depth: appr 16m Width: appr 22m Height: 80 cm Clearance to canopy: 15 meters. Minimum clearance to PA: 11 meter

Acoustic carpet (available upon request. Suited for acts featuring drums to minimize slapback from Canopy): Width 16 m Depth 8 m

RISERS: Stage risers are available inhouse upon request.

BARRIERS: It is not possible to use barriers for shows in DR Koncertsalen.

Page 9: DR Koncertsalen

May 2021

Rigging & Load information:

PA Points with available weight:

Page 10: DR Koncertsalen

May 2021